期刊文献+
共找到156篇文章
< 1 2 8 >
每页显示 20 50 100
An experimental investigation of failure mechanical behavior in cylindrical granite specimens containing two non-coplanar open fissures under different confining pressures 被引量:9
1
作者 YANG Sheng-qi DONG Jin-peng +2 位作者 YANG Jing YANG Zhen HUANG Yan-hua 《Journal of Central South University》 SCIE EI CAS CSCD 2022年第5期1578-1596,共19页
Fissures play a significant role in predicting the unstable failure of rock mass engineering.For deep rock underground engineering,rock mass containing pre-existing fissures is usually located in triaxial stress state... Fissures play a significant role in predicting the unstable failure of rock mass engineering.For deep rock underground engineering,rock mass containing pre-existing fissures is usually located in triaxial stress state.Therefore,not only pre-existing fissure but also confining pressure affects the failure mechanical behavior of rock material.In this research,the granite specimens containing two non-coplanar open fissures were investigated by a series of conventional triaxial compression tests.First,the effect of bridge angle and confining pressure on strength and deformation characteristics of granite specimens was evaluated.Results show that the triaxial compressive strength,failure axial strain,and crack damage threshold increased nonlinearly with confining pressure.Under high confining pressures,elastic modulus was insensitive to bridge angle.Then,an X-ray micro-CT scanning technique was used to analyze the internal fracture characteristics of granite specimens with respect to various bridge angles and confining pressures.Five typical crack coalescence modes were identified,namely,indirect coalescence,shear coalescence and three types of tensile coalescence.The reconstructed 3-D CT images indicated that under uniaxial or low confining pressures,the bridge angle had a significant effect on crack evolution behavior,while under high confining pressures,shear-dominated failures occurred with the development of anti-wing cracks. 展开更多
关键词 rock mechanics GRANITE three-dimensional non-coplanar open fissures X-ray micro-CT triaxial compression
在线阅读 下载PDF
Dosimetric Study of Coplanar and Non-Coplanar Intensity-Modulated Radiation Therapy Planning for Esophageal Carcinoma 被引量:3
2
作者 Ying Li Bing Liu +4 位作者 Fushan Zhai Yongfeng Yang Ming Liu Chaoen Bao Qingxiang Zhou 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2013年第4期133-138,共6页
Purpose: To compare the dosimetric impact of coplanar intensity modulated radiation therapy (IMRT) and non-coplanar IMRT for the esophageal carcinoma. Methods: There are forty-five esophageal carcinoma patients, fifte... Purpose: To compare the dosimetric impact of coplanar intensity modulated radiation therapy (IMRT) and non-coplanar IMRT for the esophageal carcinoma. Methods: There are forty-five esophageal carcinoma patients, fifteen of whom were cervical and upper thoracic (Group 1) and thirty were middle and lower thoracic (Group 2). Gross tumor volume (GTV), clinical target volume (CTV), and organs at risk (OAR) were contoured by the chief physician in the CMS-XiO treatment planning system. For each patient, one coplanar plan and two non-coplanar plans have been created using the same physical objective function. A detailed dose-volume histogram (DVH) comparison among three plans was then carried out in a tabulated format. Results: 1) In Group 1 patients with PTV volume less than 100cc, the mean dose and dose gradient of non-coplanar plan were much better than those in coplanar plan. 2) In Group 2 patients, the conformity index (CI) for coplanar and two non-coplanar plans were 0.69 ± 0.13, 0.41 ± 0.13, and 0.68 ± 0.15, respectively. The V5, V10, V20, and the mean dose to the lung were lower in the non-coplanar plans compared to ones in coplanar plan. However, the non-coplanar plans resulted in an increase in a dose to the heart, but the dose was still within heart toxicity tolerance. Conclusion: For Group 1 patients, the non-coplanar IMRT plan had less dose gradient and better mean dose than the coplanar IMRT plan. For Group 2 patients, the non-coplanar IMRT could the decrease dose to the lung tissue, thus lowering the probability of radiation pneumonia to esophageal cancer patients. The drawback of non-coplanar IMRT is that, even within toxicity tolerance, it could deliver a higher dose to the heart and spinal cord compared to the coplanar plan. Therefore, for patients with cardiology and neurology concern, non-coplanar IMRT should be used with caution. 展开更多
关键词 ESOPHAGEAL CARCINOMA COPLANAR IMRT non-coplanar IMRT
暂未订购
Fatigue Investigations on Steel Pipeline Containing 3D Coplanar and Non-Coplanar Cracks 被引量:2
3
作者 Zhongmin Xiao Wengang Zhang +1 位作者 Yanmei Zhang Mu Fan 《Computers, Materials & Continua》 SCIE EI 2020年第1期267-280,共14页
Fluctuated loadings from currents,waves and sea ground motions are observed on offshore steel pipelines,and they will result in small cracks to propagate continuously and cause unexpected damage to offshore/geotechnic... Fluctuated loadings from currents,waves and sea ground motions are observed on offshore steel pipelines,and they will result in small cracks to propagate continuously and cause unexpected damage to offshore/geotechnical infrastructures.In spite of the availability of efficient techniques and high-power computers for solving crack problems,investigations on the fatigue life of offshore pipelines with 3D interacting cracks are still rarely found in open literature.In the current study,systematic numerical investigations are performed on fatigue crack growth behaviours of offshore pipelines containing coplanar and non-coplanar cracks.Extended finite element method(XFEM)is adopted to simulate the fatigue crack growth.The qualitative validations of numerical results are made for certain cases with available experimental results.Parametric studies are conducted to investigate the influences of various important parameters on fatigue crack growth.The results will be helpful to assess the fatigue behaviours of steel pipeline with 3D interacting cracks. 展开更多
关键词 Fatigue crack growth steel pipeline coplanar cracks non-coplanar cracks XFEM
在线阅读 下载PDF
Intersecting Line of Conical Surface and Smoothly Blending of Two Tubes Whose Axes Are Non-Coplanar 被引量:1
4
作者 Genzhu Bai Zhi Wu Xiao Lin 《Journal of Applied Mathematics and Physics》 2017年第9期1887-1991,共105页
We construct two conical surfaces which take non-coplanar lines as generatrix and rational Bezier curve as ridge-line, and prove that the intersecting line of conical surface has similar properties to Bezier curve. Th... We construct two conical surfaces which take non-coplanar lines as generatrix and rational Bezier curve as ridge-line, and prove that the intersecting line of conical surface has similar properties to Bezier curve. Then, the smoothly blending of two cylinders whose axes are non-coplanar is realized by taking intersecting line of conical surface as axes. 展开更多
关键词 BEZIER CURVE Intersecting Line of Conical Surface TUBES non-coplanar TUBES Smoothly BLENDING
在线阅读 下载PDF
Dosimetric Comparison between Coplanar and Non-Coplanar Fields in Irradiation of Middle and Lower Lobes Lung Tumors
5
作者 Sherif Elzawawy Doaa Alzayat Azza Darwish 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2016年第2期130-137,共8页
Purpose: To compare between the coplanar and non-coplanar fields regarding planning target volume (PTV) coverage, conformity index and preservation of organs at risk (heart-lungs-esophagus and spinal cord). Materials ... Purpose: To compare between the coplanar and non-coplanar fields regarding planning target volume (PTV) coverage, conformity index and preservation of organs at risk (heart-lungs-esophagus and spinal cord). Materials and Methods: 10 patients presented with stage IIIA or IIIB NSCLC with a tumor located in the middle or lower lobes. Because of this location, the heart is one of the main organs at risk. Two plans, coplanar and non-coplanar 3 dimensional conformal radiotherapy plans are performed for each patient. All treatment plans are created using Xio - Computerized medical system treatment planning system. The prescribed dose is 64 Gy in 32 fractions. Results: For both plans, the maximum dose to the PTV doesn’t exceed 110% of the prescribed dose;the 95% isodose (60.8 Gy) covers at least 95% of the PTV volume and the mean conformity index values are also very similar 0.59 vs 0.61 for coplanar and non-coplanar plans respectively without statistically significant difference (P = 0.1711). Regarding organs at risk, large advantage for adding a non-coplanar field in the preservation of the heart is observed. The mean V30 values for noncoplanar plan are 17.3 Gy versus 28.9 Gy for the coplanar plan with statistically significant difference (P = 0.0060). Also, the mean V40 and V50 values for the non coplanar compared to coplanar plan are 12.6 Gy and 7.9 Gy versus 23.1 Gy and 14.9 Gy respectively, and these differences are statistically significant (P = 0.0162) (P = 0.0084). No statistically significant differences are found between coplanar and non-coplanar plans for lungs, esophagus or the spinal cord. Conclusion: Using non-coplanar beams in the irradiation of middle and lower lung tumors significantly reduces the radiation dose to the heart with the same target volume coverage and conformity index. 展开更多
关键词 Non-Small Cell Lung Cancer Non Coplanar Conformal Radiotherapy
暂未订购
CT guidance ^(125)I seed implantation for pelvic recurrent rectal cancer assisted by 3D printing individual non-coplanar template 被引量:1
6
作者 王皓 《China Medical Abstracts(Internal Medicine)》 2017年第1期44-45,共2页
Objective To analyze the difference of dosimetric parameters between pre-plan and post-plan of 125I radioactive seed implantation assisted by 3D printing individual non-coplanar template(3D printing template)for loc... Objective To analyze the difference of dosimetric parameters between pre-plan and post-plan of 125I radioactive seed implantation assisted by 3D printing individual non-coplanar template(3D printing template)for locally recurrent rectal cancer(LRRC).Methods From February 2016 to April 2016,a total of 10 patients with locally recurrent rectal cancer received 125I seeds implan- 展开更多
关键词 CT guidance I seed implantation for pelvic recurrent rectal cancer assisted by 3D printing individual non-coplanar template
原文传递
扭曲非共平面三苯胺型聚酰亚胺的合成与性能 被引量:1
7
作者 安洪利 王睢睢 +4 位作者 夏瑶 方梓昊 朱文轩 张天永 李彬 《化学工业与工程》 北大核心 2025年第4期53-60,共8页
为了满足先进显示用柔性材料的需要,从分子设计的角度出发,以三苯胺为分子骨架,设计并合成了一种三苯胺扭曲非共平面结构的二胺单体(N,N-对氨基苯基)-2-甲基-4-氟苯(FTPA)。分别采用一步热亚胺化法(OSP)和两步化学亚胺化法(CI),将FTPA与... 为了满足先进显示用柔性材料的需要,从分子设计的角度出发,以三苯胺为分子骨架,设计并合成了一种三苯胺扭曲非共平面结构的二胺单体(N,N-对氨基苯基)-2-甲基-4-氟苯(FTPA)。分别采用一步热亚胺化法(OSP)和两步化学亚胺化法(CI),将FTPA与5种商业化二酐反应制备了一系列聚酰亚胺(PI)薄膜材料。获得的PI薄膜的弹性模量TM≥2.2 GPa,拉伸强度≥82.4 MPa,线性膨胀系数(CTE)为(2.1~3.5)×10^(-5)℃-1,500 nm处光透过率达80%。制备的PI材料可在多种非质子极性溶剂中良好溶解。研究表明,在链节内引入以N中心原子为核心的局部电子离域效应相比三苯甲烷结构能够有效地提高材料的机械性能,同时在三苯胺扭曲非共平面结构的作用下降低了层间紧密堆叠,可以有效控制层间优势堆积(PLP)效应,进而提高PI薄膜的透光率。 展开更多
关键词 聚酰亚胺 非共平面结构 局部电子离域 高透光率
在线阅读 下载PDF
雁行双裂隙砂岩力学特性及能量演化规律研究 被引量:1
8
作者 郑远龙 肖桃李 +2 位作者 折海成 赵云峰 袁浩 《工业建筑》 2025年第5期239-247,共9页
以含雁行双裂隙类砂岩为研究对象,开展单轴压缩试验与PFC2D数值模拟试验,研究不同裂隙倾角α下岩样力学特性及能量演化规律。结果表明:随α的增大,试样的起裂、损伤、峰值应力均呈现出先减小再增大的变化趋势,且初始裂纹起裂位置发生改... 以含雁行双裂隙类砂岩为研究对象,开展单轴压缩试验与PFC2D数值模拟试验,研究不同裂隙倾角α下岩样力学特性及能量演化规律。结果表明:随α的增大,试样的起裂、损伤、峰值应力均呈现出先减小再增大的变化趋势,且初始裂纹起裂位置发生改变,裂纹破裂带在减少;试样加载过程中微裂纹数与能量的内在联系分析,揭示了试样破坏是一个承载力逐渐失效的过程,试样微裂纹数、能量随α的增大亦出现先减小再增大的变化趋势;引入岩样弹性能耗比K,印证了K的突变性可作为岩石失稳破坏的表征参量之一;岩样脆性指标修正系数值可反映岩石的脆性破坏特征及释放能量特征。 展开更多
关键词 雁行双裂隙 裂隙倾角 能量演化 PFC2D 弹性能耗比
原文传递
ATK驱动的HEO卫星同步带巡视场景构建与轨道机动协同设计
9
作者 李林洪 梁彦刚 +1 位作者 黎克波 王嘉欣 《国防科技大学学报》 北大核心 2025年第4期52-63,共12页
异面飞越是一种对同步带高价值目标卫星进行监测的有效方法。以椭圆轨道巡视同步带的任务场景为例,提出一种求解任意两椭圆轨道最小相遇距离的方法,证明巡视卫星的最优飞越点为升交点。使用航天任务工具箱(aerospace tool kit, ATK)仿... 异面飞越是一种对同步带高价值目标卫星进行监测的有效方法。以椭圆轨道巡视同步带的任务场景为例,提出一种求解任意两椭圆轨道最小相遇距离的方法,证明巡视卫星的最优飞越点为升交点。使用航天任务工具箱(aerospace tool kit, ATK)仿真软件对任务进行场景建模,研究J2模型下最优飞越点位置的变化。在不同的当地地方时和不同飞越方向的情况下,研究飞越点相对距离、太阳角等终端约束条件的变化规律。提出一种满足最大转移时间和终端条件约束的燃料最优转移策略,结合ATK的机动规划模块,求解了不同摄动力模型的任务参数,分析了二体模型下不同真近地点角对应的任务参数,验证了策略的有效性,为多星巡视顺序的规划提供了依据。 展开更多
关键词 航天任务工具箱 异面飞越 大椭圆轨道 最小相遇距离
在线阅读 下载PDF
CT引导下3D打印个体化非共面导航模板组织间插植放疗治疗颈部复发鼻咽癌患者的疗效及安全性
10
作者 张彦萍 韩鹏炳 +6 位作者 冀雪娟 董方 牛瑞军 杨进福 郭玮娜 瞿学琴 赵晶斌 《癌症进展》 2025年第3期297-301,共5页
目的 探讨CT引导下3D打印个体化非共面导航模板(简称3D打印模板)组织间插植放疗治疗颈部复发鼻咽癌患者的疗效及安全性。方法 选取20例颈部复发鼻咽癌患者,均行CT引导下3D打印模板组织间插植放疗,分析放疗后1、3、6个月的临床疗效及不... 目的 探讨CT引导下3D打印个体化非共面导航模板(简称3D打印模板)组织间插植放疗治疗颈部复发鼻咽癌患者的疗效及安全性。方法 选取20例颈部复发鼻咽癌患者,均行CT引导下3D打印模板组织间插植放疗,分析放疗后1、3、6个月的临床疗效及不良反应发生情况。结果 20例颈部复发鼻咽癌患者均完成近距离插植治疗,1例患者未按时复查,19例按时进行复查。放疗后1、3、6个月,10例患者疗效评价为完全缓解,8例患者疗效评价为部分缓解,1例患者放疗后6个月复查发现残留病灶边缘出现新发病灶,疗效评价为疾病进展。19例颈部复发鼻咽癌患者均未出现明显的放射性损伤,发生率为0%。结论 CT引导下3D打印模板组织间插植治疗颈部复发鼻咽癌患者安全有效,可使患者临床获益。 展开更多
关键词 颈部复发鼻咽癌 3D打印个体化非共面导航模板 组织间插植放疗
暂未订购
非共面VMAT联合DIBH技术在周围型肺癌立体定向放疗中的应用
11
作者 蓝茂英 冯飞燕 +3 位作者 陈彩金 张路 孙建聪 伍锐 《广州医科大学学报》 2025年第6期11-17,共7页
目的:比较共面和非共面容积旋转调强(VMAT)在深吸气屏气(DIBH)技术下肺癌立体定向放射治疗(SBRT)中的剂量学差异。方法:选取13例接受SBRT的周围型肺癌患者,基于DIBHCT设计共面VMAT(cVMAT)和非共面VMAT(nVMAT)计划。评估靶区适形指数(CI... 目的:比较共面和非共面容积旋转调强(VMAT)在深吸气屏气(DIBH)技术下肺癌立体定向放射治疗(SBRT)中的剂量学差异。方法:选取13例接受SBRT的周围型肺癌患者,基于DIBHCT设计共面VMAT(cVMAT)和非共面VMAT(nVMAT)计划。评估靶区适形指数(CI)、均匀性指数(HI)、梯度指数(R_(50%))、距计划靶区2 cm的最大剂量(D_(2cm))、高剂量溢出(HD_(loc)),以及危及器官(OARs)全肺20 Gy剂量照射的体积占肺体积的百分比(V_(20)),心脏、食管、脊髓的最大剂量(D_(max))。同时分析机器跳数(MU)和计划复杂性参数,包括调制复杂性得分(MCSv)和平均叶片对展宽(ALPO)。结果:cVMAT与nVMAT两组计划均满足临床剂量要求,靶区V100%、D99%、CI和HI差异均无统计学意义(均P>0.05)。nVMAT在剂量跌落和溢出方面更优,R_(50%)、D_(2cm)、HD_(loc)显著降低(均P<0.05)。OARs剂量显著改善,全肺V_(20)降低6.6%,脊髓、心脏和食管D_(max)分别减少27.3%、18.9%和35.4%(均P<0.05)。两组计划的MU和计划复杂性无显著差异(均P>0.05)。结论:在DIBH条件下,nVMAT在确保靶区覆盖的同时改善剂量梯度并降低危及器官剂量,为肺癌SBRT提供更安全有效的选择。 展开更多
关键词 放射疗法 适形 非共面容积旋转调强 深吸气屏气 周围型肺癌 立体定向放射治疗 剂量学分析
暂未订购
共面与非共面调强放射治疗在局限期小细胞肺癌患者预防性海马保护性全脑放射治疗中的剂量学比较
12
作者 汤幸妮 庞笑珍 +3 位作者 侯利桥 周超 于长辉 贾海健 《医疗装备》 2025年第5期29-35,共7页
目的探讨共面调强放射治疗(CO-IMRT)和非共面调强放射治疗(NC-IMRT)在小细胞肺癌(SCLC)患者预防性海马保护性全脑放射治疗(WBRT)中的剂量学差异。方法回顾性分析2019-2020年于医院放疗科接受固定野调强(FF-IMRT)技术进行预防性WBRT的20... 目的探讨共面调强放射治疗(CO-IMRT)和非共面调强放射治疗(NC-IMRT)在小细胞肺癌(SCLC)患者预防性海马保护性全脑放射治疗(WBRT)中的剂量学差异。方法回顾性分析2019-2020年于医院放疗科接受固定野调强(FF-IMRT)技术进行预防性WBRT的20例患者的临床资料。对所有患者进行CO-IMRT和NC-IMRT计划,两种计划均满足美国肿瘤放射治疗协作组织(RTOG)0614和RTOG 0933的剂量限制标准且三维剂量验证均合格后,比较两种计划的计划靶区(PTV)剂量参数、典型病例的剂量分布图、危及器官(OARs)剂量参数、计划执行指标[包括机器跳数(MU)、治疗时间及三维验证通过率]。结果两种计划的PTV D98%、D2%、均匀性指数(HI)比较,差异无统计学意义(P>0.05);NC-IMRT的Dmedian、适形性指数(CI)大于CO-IMRT,差异有统计学意义(P<0.05)。两种计划的剂量覆盖体积相同,但是NC-IMRT比CO-IMRT的剂量覆盖更均匀,NC-IMRT的左侧和右侧海马区、左侧眼球、左侧和右侧晶体及脑干的Dmax均低于CO-IMRT,左侧海马区的Dmean低于CO-IMRT,差异有统计学意义(P<0.05)。NC-IMRT的MU少于CO-IMRT,治疗时间长于CO-IMRT,差异有统计学意义(P<0.05),但两种计划的三维验证通过率比较,差异无统计学意义(P>0.05)。结论两种计划均能实现预防性WBRT,同时保护海马区。但NC-IMRT比CO-IMRT的靶区剂量均匀性及对OARs保护性更好。 展开更多
关键词 全脑放射治疗 海马保护 非共面调强放射治疗 小细胞肺癌 调强放射治疗
暂未订购
非共面VMAT技术在左侧乳腺癌改良根治术后胸壁加锁骨区(含内乳淋巴结)放疗中的应用价值
13
作者 闫雪娜 赵旭冉 +4 位作者 洪天航 王文宇 陈辛元 门阔 戴建荣 《现代肿瘤医学》 2025年第7期1117-1125,共9页
目的:探究左侧乳腺癌改良根治术后对胸壁、锁骨上以及内乳淋巴结区域联合照射时,非共面容积旋转调强技术(non-coplanar volumetric modulated arc therapy,nVMAT)与容积旋转调强技术(volumetric modulated arc therapy,VMAT)相比的临床... 目的:探究左侧乳腺癌改良根治术后对胸壁、锁骨上以及内乳淋巴结区域联合照射时,非共面容积旋转调强技术(non-coplanar volumetric modulated arc therapy,nVMAT)与容积旋转调强技术(volumetric modulated arc therapy,VMAT)相比的临床应用价值。方法:本研究采用回顾性分析方法,以随机取样法选取10例既往于本医院接受左侧乳腺癌改良根治术后采用VMAT技术进行放疗的患者。针对每一位患者在给予相同处方剂量和相同归一条件下,添加一个非共面往返弧,重新设计nVMAT计划。并将其与实际治疗使用的VMAT计划做对比,分析靶区和周围危及器官(organs at risk,OARs)的剂量学差异,评估nVMAT技术的临床应用价值。结果:靶区,适形性指数,nVMAT计划0.88,VMAT计划0.86;均匀性指数,nVMAT计划0.10,VMAT计划0.13,差异有统计学意义(P<0.05)。危及器官,nVMAT计划优势显著。心脏V_(30)、V_(20)、V_(10)、V_(5)分别降低2%、3%、3%、2.6%,平均剂量降1 Gy;健侧肺V_(10)、V_(5)分别降低0.5%、4%,平均剂量降0.5 Gy;患侧肺V_(20)降低1%,平均剂量降低1.7 Gy;健侧乳腺平均剂量降0.5 Gy;左前降支(left anterior descending artery,LAD)的V_(30)降15.67%,平均剂量降3.5 Gy,上述差异均有统计学意义(P<0.05)。患侧肺V_(10)和V_(5)分别降低0.52%和0.3%,差异无统计学意义(P>0.05)。其他OARs,左侧肱骨头、食管、肝和正常组织的平均剂量有所改善,且差异有统计学意义(P<0.05);其余各OARs虽有改善但差异无统计学意义(P>0.05)。结论:乳腺癌放射治疗中,nVMAT技术显著提升靶区适形性与均匀性,同时降低周围危及器官剂量,对心脏、健侧肺效果更佳,临床可酌情考虑应用该技术。 展开更多
关键词 非共面VMAT 乳腺癌 计划设计 心脏保护
暂未订购
基于星点关联和轨迹匹配的空间目标检测算法
14
作者 甄子涵 郁丰 刘佳鑫 《光学与光电技术》 2025年第3期102-110,共9页
空间交会任务执行成功与否的关键在于目标检测的准确性。针对远距离异面交会过程中空间目标与恒星成像相似、特征少、成像轨迹随机、星点像移缓慢等特点,提出了一种基于星点关联和轨迹匹配的空间目标检测算法。首先对多帧星图图像进行... 空间交会任务执行成功与否的关键在于目标检测的准确性。针对远距离异面交会过程中空间目标与恒星成像相似、特征少、成像轨迹随机、星点像移缓慢等特点,提出了一种基于星点关联和轨迹匹配的空间目标检测算法。首先对多帧星图图像进行预处理,包括噪声处理、阈值分割、质心定位、以及图像配准,然后,基于所提出的关联度函数与关联法则进行多帧星点关联,滤除游离噪点的同时提取出星点帧间运动的轨迹,最后以目标尺寸、速度、方向三个指标进行轨迹匹配,检测出空间目标。经仿真验证算法满足异面交会过程中的检测要求,在存在一定程度帧间失配情况下,空间目标检测率可达99.8%,虚警率为0.04%,可以适应复杂空间环境下的目标检测需求。 展开更多
关键词 空间小目标 目标检测 异面交会 可见光图像 态势感知
原文传递
共面与非共面容积旋转调强技术在胸腺肿瘤放射治疗中的剂量学比较
15
作者 孙斌 徐程 +3 位作者 杜司续 钟思瑶 原静 高玉艳 《肿瘤预防与治疗》 2025年第7期587-592,共6页
目的:探讨共面与非共面容积旋转调强(volumetric modulated arc therapy,VMAT)技术在胸腺肿瘤治疗中,是否具有剂量学优势。方法:随机选取14例胸腺肿瘤患者,分别制定共面及非共面VMAT计划,并对两组的计划靶区(planning target volume,PTV... 目的:探讨共面与非共面容积旋转调强(volumetric modulated arc therapy,VMAT)技术在胸腺肿瘤治疗中,是否具有剂量学优势。方法:随机选取14例胸腺肿瘤患者,分别制定共面及非共面VMAT计划,并对两组的计划靶区(planning target volume,PTV)和危及器官剂量学参数进行比较,包括靶区适形度指数(conformity index,CI)、剂量均匀性指数(homogeneity index,HI),全肺受照射量≥30 Gy、20 Gy、5 Gy的体积V30,V20,V5和全肺平均受照剂量(mean lung dose,MLD),心脏V40、V30和平均受照剂量Dmean,以及食管和气管接受最大照射的1 cc体积内的剂量最小值D1cc、脊髓的最大受照剂量Dmax。使用SPSS配对样本t检验方法或Wilcoxon秩和检验进行统计学分析,以P<0.05为差异有统计学意义。结果:共面计划PTV的的CI、HI均优于非共面计划(P<0.05);共面计划双肺的V30优于非共面计划(P<0.05),但V5、MLD高于非共面计划(P<0.05),V20差异无统计学意义(P=0.875);共面计划食管的Dmean低于非共面计划(P<0.05),共面计划跳数高于非共面跳数(P<0.05)。而对于心脏的V40、V30、Dmean,食管的D1cc,气管的D1cc、Dmean以及脊髓的Dmax,两组间差异无统计学意义(P>0.05)。结论:对于胸腺肿瘤非共面计划在保护双肺、心脏、气管方面具有一定优势,但食管受量更高。 展开更多
关键词 胸腺肿瘤 容积旋转调强 共面计划 非共面计划
暂未订购
非共面双裂隙煤岩三轴力学行为及内部裂纹演化特征研究
16
作者 赵仁宝 丁立 +3 位作者 郑义宁 刘飞 张朋 王明辉 《现代矿业》 2025年第6期50-54,共5页
随着矿井开挖深度日益增加,围压以及天然缺陷造成工作面不稳定性的问题成为关注热点。基于室内力学试验和离散元数值方法,针对陕西省神木市河畔煤矿煤样,分析了不同围压下含非共面双裂隙煤岩的力学强度、变形特征、破坏模式以及内部裂... 随着矿井开挖深度日益增加,围压以及天然缺陷造成工作面不稳定性的问题成为关注热点。基于室内力学试验和离散元数值方法,针对陕西省神木市河畔煤矿煤样,分析了不同围压下含非共面双裂隙煤岩的力学强度、变形特征、破坏模式以及内部裂纹演化规律。研究结果表明:煤岩力学性能满足摩尔-库仑准则,随着围压增加,峰值强度以及峰值应变均呈线性增长;含有不同岩桥角度的非共面双裂隙对煤岩的力学参数具有明显的劣化作用,岩桥倾角为0°、30°、60°、90°和120°时,煤样的峰值强度下降幅度分别为16.4%、14.2%、26.4%、38.5%和19.8%;与岩桥角度相比,围压对试样破坏模式的影响更大,随着围压增加,煤样由张拉-混合拉剪破坏转变为剪切破坏,煤岩从脆性破坏向延性破坏转变;此外,裂纹数量亦受到围压和岩桥倾角的双重影响。研究结果为深地矿井开采安全及稳定性提供一定指导。 展开更多
关键词 非共面双裂隙 破坏模式 裂纹演化规律
在线阅读 下载PDF
两个轴异面的管道拼接 被引量:13
17
作者 雷娜 崔丽 伍铁如 《吉林大学学报(理学版)》 CAS CSCD 北大核心 2002年第2期138-140,共3页
证明二轴异面的圆管在其任意平面截口处通常不能用三次代数曲面 GC1拼接 ,提出构造轴线与给定二圆管的轴分别共面的辅助圆柱 ,并利用二轴共面的吴文俊公式实现了给定圆管的分两段的三次
关键词 异面管 吴文俊公式 曲面拼接 轴异面 管道拼接 CAGD 光滑拼接 二次曲面
在线阅读 下载PDF
非共面野在脑胶质瘤调强放射治疗中的剂量学优势 被引量:15
18
作者 陈旭明 姚升宇 +2 位作者 许奕 徐冰 赵国旗 《中国医学物理学杂志》 CSCD 2011年第2期2475-2477,共3页
目的:探讨非共面射野在脑胶质瘤调强放疗中的应用特点及剂量学优势,为非共面野应用于脑胶质瘤调强放疗临床应用提供理论依据。材料方法:对6例脑胶质瘤患者分别设计5野共面调强计划和在此之上增加一个非共面野的6野调强计划,利用剂量体... 目的:探讨非共面射野在脑胶质瘤调强放疗中的应用特点及剂量学优势,为非共面野应用于脑胶质瘤调强放疗临床应用提供理论依据。材料方法:对6例脑胶质瘤患者分别设计5野共面调强计划和在此之上增加一个非共面野的6野调强计划,利用剂量体积直方图评价两种计划方法的正常组织照射剂量、适形度指数以及不均匀指数。结果:6野非共面计划比5野共面计划有更好适形性和均匀性;同时减少了眼球、晶体、视神经照射剂量。结论:在脑胶质瘤的调强放疗中,加入非共面野计划比共面计划有更明显的剂量学优势。 展开更多
关键词 非共面野 脑胶质瘤 调强放射治疗 剂量学
暂未订购
基于圆特征和异面点特征的位姿测量 被引量:9
19
作者 张丽敏 朱枫 +1 位作者 郝颖明 王敏燕 《光子学报》 EI CAS CSCD 北大核心 2015年第11期83-88,共6页
通过增加常见的点特征为位姿测量提供空间几何约束,分析利用圆形目标和与之异面的特征点进行单目视觉定位时位姿解个数的情况.以光心和特征点位于圆平面两侧为前提条件,运用几何方法证明了特征点与光心和圆平面的相对位置决定了位姿解... 通过增加常见的点特征为位姿测量提供空间几何约束,分析利用圆形目标和与之异面的特征点进行单目视觉定位时位姿解个数的情况.以光心和特征点位于圆平面两侧为前提条件,运用几何方法证明了特征点与光心和圆平面的相对位置决定了位姿解的个数,并求出唯一位姿解和两组位姿解时光心、圆平面和特征点的位置关系,提出了基于圆特征和异面点特征的位姿求解算法,实现了6维位姿量测量,仿真实验和实物实验结果验证了算法的有效性和准确性. 展开更多
关键词 单目视觉 位姿测量 空间几何约束 位姿解个数 圆特征 异面特征点 二义性
在线阅读 下载PDF
非共面射野在胸段食管癌术后三维适形放疗中的剂量学研究 被引量:5
20
作者 刘海 李金凯 +3 位作者 王晓萍 赵锐 张新良 卢志强 《中华肿瘤防治杂志》 CAS 2011年第13期1036-1038,1053,共4页
目的:对比研究前野共面及非共面射野在计划靶区纵轴长度19 cm的胸段食管癌术后三维适形放疗中的剂量分布。方法:对32例适用病例进行三维适形放疗计划设计,为每例患者设计2套计划方案,A方案为所有射野均采用共面设计,B方案前野改为非共... 目的:对比研究前野共面及非共面射野在计划靶区纵轴长度19 cm的胸段食管癌术后三维适形放疗中的剂量分布。方法:对32例适用病例进行三维适形放疗计划设计,为每例患者设计2套计划方案,A方案为所有射野均采用共面设计,B方案前野改为非共面射野,其余射野共面设计并同A方案射野角度相同,对两套治疗计划进行临床靶区CTV、计划靶区PTV以及危及器官剂量分布的对比。结果:与A方案相比,采用前野非共面射野的B方案CTV及PTV的最大剂量(Dmax)和平均剂量(Dmean)均显著下降(P<0.05),体积百分比V110显著降低(P<0.05),HI值显著低于A方案〔(1.09±0.01)vs(1.06±0.01),P<0.05〕,差异具有统计学意义。两肺的各项指标差异无统计学意义,脊髓最大剂量Dmax低于A套计划(P<0.05)。对于心脏,B方案V40值略高于A方案,但在临床接受范围内。采用非共面前野设计的三维适形计划在靶区的均匀性等剂量学分布上有所提高,脊髓受量显著下降〔(42.17±1.89)Gyvs(40.65±1.86)Gy,P<0.05〕,剂量分布得到改善。结论:当食管癌长度超出楔形野照射允许范围时,适时合理运用非共面射野,可获得较理想的剂量分布,有利于满足临床的剂量学要求。 展开更多
关键词 胸段食管癌术后 非共面射野 三维适形放疗 剂量分布
原文传递
上一页 1 2 8 下一页 到第
使用帮助 返回顶部