Fluorescent probes have wide applications in biological and environmental analysis due to their advantages of simple operation, convenient flexibility, high sensitivity and efficiency. They are considered to be promis...Fluorescent probes have wide applications in biological and environmental analysis due to their advantages of simple operation, convenient flexibility, high sensitivity and efficiency. They are considered to be promising tools for accurate analysis of agriculture- and food-related hazardous substances. In this review, the types and characteristics of the near-infrared fluorescence probes (NIFPs) are briefly described. The recent advances of NIFPs for precisely detecting various hazardous substances including heavy metals, sulfite and related sulfiting agents and hydrogen peroxide are summarized. Finally, the present challenges and future perspectives faced by NIFPs in food safety analysis are discussed.展开更多
Using 2-dicyanomethylene-3-cyano-4,5,5-trimethyl-2,5-dihydrofuran(TCF)as a near-infrared fluorescent chromophore,we designed and synthesized a TCF-based fluorescent probe TCF-NS by introducing 2,4-dinitrophenyl ether ...Using 2-dicyanomethylene-3-cyano-4,5,5-trimethyl-2,5-dihydrofuran(TCF)as a near-infrared fluorescent chromophore,we designed and synthesized a TCF-based fluorescent probe TCF-NS by introducing 2,4-dinitrophenyl ether as the recognized site for H_(2)S.The probe TCF-NS displayed a rapid-response fluorescent against H_(2)S with high sensitivity and selection but had no significant fluorescence response to other biothiols.Furthermore,TCF-NS was applied to sense H_(2)S in living cells successfully with minimized cytotoxicity and a large Stokes shift.展开更多
Rheumatoid arthritis,being a chronic autoimmune malady,may culminate in joint malformation and incapacitation in severe instances.Nevertheless,monitoring the heterogeneity of the viscosity microenvironment in local jo...Rheumatoid arthritis,being a chronic autoimmune malady,may culminate in joint malformation and incapacitation in severe instances.Nevertheless,monitoring the heterogeneity of the viscosity microenvironment in local joint areas remains challenging.Hence,we have developed a near-infrared(NIR)-emitting fluorescence lifetime probe WY-V for dual fluorescence lifetime imaging microscopy(FLIM)/NIR optical imaging,featuring precise targeting capabilities to the endoplasmic reticulum(ER)and lipid droplets(LD).This probe modulates distinct fluorescence lifetimes in the varying viscosity environments of these organelles,allowing for the quantification of their respective viscosities.Using FLIM/NIR optical imaging of joint tissues from arthritic mice,the probe accurately discerned the viscosity of inflamed cells at diverse sites,reveals the viscosity heterogeneity present within the arthritic tissues.Therefore,this research offers a potent biological instrument for clinical diagnosis and pathological examination of rheumatoid arthritis.展开更多
A pancreas surgeon’s constant goal is to do"less damage,more radical".Currently,a small number of highly trained surgeons opt for single-incision laparoscopic pancreaticoduodenectomy(SILPD)or single-incisio...A pancreas surgeon’s constant goal is to do"less damage,more radical".Currently,a small number of highly trained surgeons opt for single-incision laparoscopic pancreaticoduodenectomy(SILPD)or single-incision plus one-port LPD(SILPD+1)to minimize post-operative pain,improve convalescence,and provide a more pleas-ing cosmetic outcome[1,2].Additionally,some skilled surgeons have claimed that laparoscopic duodenum-preserving complete pancreatic head resections(LDPPHR)result in less trauma and en-hanced quality of life[3,4].However,LDPPHR is still challenging because of its lengthy learning curve and"sword-fighting"impact.Additionally,there has not been any global reporting on the suit-ability of single-incision plus one-port DPPHR with pancreaticogas-trostomy(SILDPPHR-T+1)in place of SILPD+1.This study aimed to illustrate the SILDPPHR-T+1 procedure specifics for a patient with pancreatic head intraductal papillary mucinous neoplasm(IPMN)(main pancreatic duct type)(MD-IPMN).展开更多
AIM: To investigate feasibility and accuracy of near-infrared fluorescence imaging using indocyanine green: nanocolloid for sentinel lymph node (SLN) detection in gastric cancer.METHODS: A prospective, single-institut...AIM: To investigate feasibility and accuracy of near-infrared fluorescence imaging using indocyanine green: nanocolloid for sentinel lymph node (SLN) detection in gastric cancer.METHODS: A prospective, single-institution, phase I feasibility trial was conducted. Patients suffering from gastric cancer and planned for gastrectomy were included. During surgery, a subserosal injection of 1.6 mL ICG:Nanocoll was administered around the tumor. NIR fluorescence imaging of the abdominal cavity was performed using the Mini-FLARE™ NIR fluorescence imaging system. Lymphatic pathways and SLNs were visualized. Of every detected SLN, the corresponding lymph node station, signal-to-background ratio and histopathological diagnosis was determined. Patients underwent standard-of-care gastrectomy. Detected SLNs outside the standard dissection planes were also resected and evaluated.RESULTS: Twenty-six patients were enrolled. Four patients were excluded because distant metastases were found during surgery or due to technical failure of the injection. In 21 of the remaining 22 patients, at least 1 SLN was detected by NIR Fluorescence imaging (mean 3.1 SLNs; range 1-6). In 8 of the 21 patients, tumor-positive LNs were found. Overall accuracy of the technique was 90% (70%-99%; 95%CI), which decreased by higher pT-stage (100%, 100%, 100%, 90%, 0% for respectively Tx, T1, T2, T3, T4 tumors). All NIR-negative SLNs were completely effaced by tumor. Mean fluorescence signal-to-background ratio of SLNs was 4.4 (range 1.4-19.8). In 8 of the 21 patients, SLNs outside the standard resection plane were identified, that contained malignant cells in 2 patients.CONCLUSION: This study shows successful use of ICG:Nanocoll as lymphatic tracer for SLN detection in gastric cancer. Moreover, tumor-containing LNs outside the standard dissection planes were identified.展开更多
Surgery is still the primary curative treatment for gastric cancer,which includes resection of the tumor with adequate margins and extended lymphadenectomy.In order to improve the operative results and the quality of ...Surgery is still the primary curative treatment for gastric cancer,which includes resection of the tumor with adequate margins and extended lymphadenectomy.In order to improve the operative results and the quality of life of patients,several endeavors have been made toward precision medicine through image-guided surgery,allowing access to real-time intraoperative anatomy and accurate tumor staging.The goal of the surgeon is to achieve a more precise,individualized,and less invasive surgery without compromising oncological efficiency and safety.In this perspective,we have demonstrated the role of indocyanine green(ICG)and near-infrared(NIR)fluorescence imaging method in gastric cancer surgery.This technique may be used to improve localization of the tumor,detection of sentinel lymph nodes(SLN),real-time lymphatic mapping,and blood flow assessment(anastomosis perfusion).展开更多
Fluorescence intraoperative cholangiography(IOC) is a potential alternative for identifying anatomical variation and preventing iatrogenic bile duct injuries by using the near-infrared probe indocyanine green(ICG)...Fluorescence intraoperative cholangiography(IOC) is a potential alternative for identifying anatomical variation and preventing iatrogenic bile duct injuries by using the near-infrared probe indocyanine green(ICG). However, the dynamic process and mechanism of fluorescence IOC have not been elucidated in previous publications. Herein, the optical properties of the complex of ICG and bile, dynamic fluorescence cholangiography and iatrogenic bile duct injuries were investigated. The emission spectrum of ICG in bile peaked at 844 nm and ICG had higher tissue penetration. Extrahepatic bile ducts could fluoresce 2 min after intravenous injection, and the fluorescence intensity reached a peak at 8 min. In addition, biliary dynamics were observed owing to ICG excretion from the bile ducts into the duodenum. Quantitative analysis indicated that ICG-guided fluorescence IOC possessed a high signal to noise ratio compared to the surrounding peripheral tissue and the portal vein. Fluorescence IOC was based on rapid uptake of circulating ICG in plasma by hepatic cells, excretion of ICG into the bile and then its interaction with protein molecules in the bile. Moreover, fluorescence IOC was sensitive to detect bile duct ligation and acute bile duct perforation using ICG in rat models. All of the results indicated that fluorescence IOC using ICG is a valid alternative for the cholangiography of extrahepatic bile ducts and has potential for measurement of biliary dynamics.展开更多
BACKGROUND Near-infrared fluorescence imaging via using intravenous indocyanine green(ICG)has a wide range of applications in multiple surgical scenarios.In lapa-roscopic cholecystectomy(LC),it facilitates intraoperat...BACKGROUND Near-infrared fluorescence imaging via using intravenous indocyanine green(ICG)has a wide range of applications in multiple surgical scenarios.In lapa-roscopic cholecystectomy(LC),it facilitates intraoperative identification of the biliary system and reduces the risk of bile duct injury.However,the usual single color fluorescence imaging(SCFI)has limitations in manifesting the fluorescence signal of the target structure when its intensity is relatively low.Moreover,sur-geons often experience visual fatigue.We hypothesized that a novel imaging stra-tegy,named multi-color fluorescence imaging(MCFI),could potentially address these issues by decreasing hepatic and background fluorescence pollution and improving biliary visualization.AIM To investigate the novel imaging strategy MCFI in LC.METHODS This was a single-center retrospective study conducted at Peking Union Medical College Hospital,Beijing,China.Patients who underwent LC from June 2022 to March 2023 by the same surgical team were enrolled.Demographic features,clinical and surgical information were collected.The clarity,visual comfort,and effectiveness of different imaging strategies were subjectively evaluated by surgeons.RESULTS A total of 155 patients were included,60 patients were in the non-ICG group in which only bright light illuminance without ICG was applied,60 patients were in the SCFI group,and 35 patients were in the MCFI group.No statist-ically significant differences were found in demographics or clinical history.Post-surgical complications were minimal in all 3 groups with no significant differences observed.MCFI improved the clarity of imaging and visual comfort.Clarity of imaging and visual comfort were improved with MCFI.CONCLUSION MCFI improves biliary visualization and reduces liver fluorescence contamination,which supports its routine use in LC.MCFI may also be a better choice than SCFI in other clinical settings.展开更多
Objective:Laparoscopic pelvic lymph node dissection(LPND),which is an effective therapy for endometrial cancer,is challenging because of the complexity of the procedure and the occurrence of postoperative complication...Objective:Laparoscopic pelvic lymph node dissection(LPND),which is an effective therapy for endometrial cancer,is challenging because of the complexity of the procedure and the occurrence of postoperative complications.This study aimed to explore whether indocyanine green(ICG)-enhanced nearinfrared(NIR)fluorescence-guided LPND is superior to LPND in the context of early-stage endometrial carcinoma.Methods:In this retrospective study,we included the medical records of 190 patients with early-stage endometrioid adenocarcinoma who underwent LPND at the Department of Obstetrics and Gynecology,Sir Run Run Shaw Hospital,Zhejiang University School of Medicine between January 2019 and January 2021.Depending on whether ICG-enhanced NIR fluorescence guidance was used,the patients were assigned to the ICG group or non-ICG group.Patients were followed-up for one year after surgery.Data on demographic characteristics,pathological results,operative outcomes,and complications were collected and analyzed.Results:The baseline characteristics were comparable between the ICG group and non-ICG group,including age,BMI,pregnancy history,and preoperative hemoglobin.For surgical outcomes,the patients in ICG group had significantly lower intraoperative blood loss(50 mL vs.120 mL,p<0.001),less postoperative pelvic drainage time(4.14±1.44 d vs.5.70±1.89 d,p¼0.001),shorter duration of hospital stay(5.26±1.41 d vs.7.37±1.85 d,p¼0.003),higher number of positive pelvic lymph nodes(PLNs)(1 vs.0,p¼0.003),and more PLN-positive cases(16.0%vs.3.6%,p¼0.003)than the patients in non-ICG group.However,no significant differences were noted in blood transfusion requirement,operative time,hemoglobin level decreases,number of PLNs harvested,or the presence of lymphocysts between the two groups.Conclusion:Our study showed that ICG-enhanced NIR fluorescence-guided operation may improve the accuracy and safety of LPND.展开更多
Objective: To evaluate the imaging potential of a novel near-infrared(NIR) probe conjugated to COC183 B2 monoclonal antibodies(MAb) in ovarian cancer(OC).Methods: The expression of OC183 B2 antigen in OC was determine...Objective: To evaluate the imaging potential of a novel near-infrared(NIR) probe conjugated to COC183 B2 monoclonal antibodies(MAb) in ovarian cancer(OC).Methods: The expression of OC183 B2 antigen in OC was determined by immunohistochemical(IHC) staining using tissue microarrays with the H-score system and immunofluorescence(IF) staining of tumor cell lines.Imaging probes with the NIR fluorescent dye cyanine 7(Cy7) conjugated to COC183 B2 Mab were chemically engineered. OC183 B2-positive human OC cells(SKOV3-Luc) were injected subcutaneously into BALB/c nude mice. Bioluminescent imaging(BLI) was performed to detect tumor location and growth. COC183 B2-Cy7 at 1.1,3.3, 10, or 30 μg were used for in vivo fluorescence imaging, and phosphate-buffered saline(PBS), free Cy7 dye and mouse isotype immunoglobulin G(IgG)-Cy7(delivered at the same doses as COC183 B2-Cy7) were used as controls.Results: The expression of OC183 B2 with a high H-score was more prevalent in OC tissue than fallopian tube(FT) tissue. Among 417 OC patients, the expression of OC183 B2 was significantly correlated with the histological subtype, histological grade, residual tumor size, relapse state and survival status. IF staining demonstrated that COC183 B2 specifically expressed in SKOV3 cells but not HeLa cells. In vivo NIR fluorescence imaging indicated that COC183 B2-Cy7 was mainly distributed in the xenograft and liver with optimal tumor-to-background(T/B)ratios in the xenograft at 30 μg dose. The highest fluorescent signals in the tumor were observed at 96 h postinjection(hpi). Ex vivo fluorescence imaging revealed the fluorescent signals mainly from the tumor and liver. IHC analysis confirmed that xenografts were OC183 B2 positive.Conclusions: COC183 B2 is a good candidate for NIR fluorescence imaging and imaging-guided surgery in OC.展开更多
Imaging hypoxia using fluorescence probes for nitroreductase(NTR) have attracted much attention in last decade. At least three different linkers have been commonly used to connect the recognition unit and reporting ...Imaging hypoxia using fluorescence probes for nitroreductase(NTR) have attracted much attention in last decade. At least three different linkers have been commonly used to connect the recognition unit and reporting unit in reported probes for NTR. Meanwhile, the linker is known to be a key factor for achieving best sensing performance. In this work, three near-infrared fluorescence probes CyNP-1, CyNP-2 and CyNP-3 were designed and synthesized from an aminocyanine dye CyNP. The three probes have the same recognition unit and same fluorescence reporting unit, but different linkers. CyNP-1 was found to have the best sensing performance for NTR with 40-fold of fluorescence enhancement. It is well investigated how the difference of the linkers brings out the different sensing performance by HPLC, MS and docking calculations. In the end, CyNP-1 was found to have good selectivity for NTR and used to imaging hypoxia in Hela cells.展开更多
A 67-year-old female presented with unexplained abdominal pain. A contrast-enhanced computed tomography scan of the abdomen incidentally revealed a mass in the uncinate process of the pancreas. This mass was resected ...A 67-year-old female presented with unexplained abdominal pain. A contrast-enhanced computed tomography scan of the abdomen incidentally revealed a mass in the uncinate process of the pancreas. This mass was resected and based on histopathological findings, diagnosed as a solitary fibrous tumor (SFT) of the pancreas. A SFT is an extremely rare benign mesenchymal tumor that in 65% of cases affects the visceral pleura but can also affect extra-pleural sites. The intraoperative demarcation of pancreatic tumors, such as SFTs, can bechallenging. In this report, the first clear intraoperative identification of a SFT of the pancreas in a human was shown using near-infrared fluorescence and methylene blue.展开更多
BACKGROUND After an esophagectomy, the stomach is most commonly used to restore continuity of the upper gastrointestinal tract. These esophago-gastric anastomoses are prone to serious complications such as leakage ass...BACKGROUND After an esophagectomy, the stomach is most commonly used to restore continuity of the upper gastrointestinal tract. These esophago-gastric anastomoses are prone to serious complications such as leakage associated with high morbidity and mortality. Graft perfusion is considered to be an important predictor for anastomotic integrity. Based on the current literature we believe Indocyanine green fluorescence angiography(ICGA) is an easy assessment tool for gastric tube(GT) perfusion, and it might predict anastomotic leakage(AL).AIM To evaluate feasibility and effectiveness of ICGA in GT perfusion assessment and as a predictor of AL.METHODS This study was designed according to the PRISMA guidelines and registered in the PROSPERO database. PubMed and EMBASE were independently searched by 2 reviewers for studies presenting data on intraoperative ICGA GT perfusion assessment during esophago-gastric reconstruction after esophagectomy.Relevant outcomes such as feasibility, complications, intraoperative surgical changes based on ICGA findings, quantification attempts, anatomical data and the impact of ICGA on postoperative anastomotic complications, were collected by 2 independent researchers. The quality of the included articles was assessed based on the Methodological Index for Non-Randomized Studies. The 19 included studies presented data on 1192 esophagectomy patients, in 758 patients ICGA was used perioperative to guide esophageal reconstruction.RESULTS The 19 included studies for qualitative analyses all described ICGA as a safe and easy method to evaluate gastric graft perfusion. AL occurred in 13.8% of the entire cohort, 10% in the ICG guided group and 20.6% in the control group(P <0.001). When poorly perfused cases are excluded from the analyses, the difference in AL was even larger(AL well-perfused group 6.3% vs control group 20.5%, P <0.001). The AL rate in the group with an altered surgical plan based on the ICG image was 6.5%, similar to the well perfused group(6.3%) and significantly less than the poorly perfused group(47.8%)(P < 0.001), suggesting that the technique is able to identify and alter a potential bad outcome.CONCLUSION ICGA is a safe, feasible and promising method for perfusion assessment. The lower AL rate in the well perfused group suggest that a good fluorescent signal predicts a good outcome.展开更多
Near-infrared fluorescence(NIRF)is a technique of augmented reality that,when applied in the operating theatre,allows the colorectal surgeon to visualize and assess bowel vascularization,to identify lymph nodes draini...Near-infrared fluorescence(NIRF)is a technique of augmented reality that,when applied in the operating theatre,allows the colorectal surgeon to visualize and assess bowel vascularization,to identify lymph nodes draining a cancer site and to identify ureters.Herein,we review the literature regarding NIRF in colorectal surgery.展开更多
Nonalcoholic fatty liver disease(NAFLD)can cause serious liver damage.Early diagnosis and effective treatment of NAFLD can greatly improve treatment rates.The initiation and development of NAFLD has been closely linke...Nonalcoholic fatty liver disease(NAFLD)can cause serious liver damage.Early diagnosis and effective treatment of NAFLD can greatly improve treatment rates.The initiation and development of NAFLD has been closely linked to endoplasmic reticulum(ER)stress,which might cause ER viscosity variations.Therefore,if the internal relationship between ER viscosity and NAFLD is clarified,an effective approach for early diagnosis may result.Herein,we fabricated a novel near-infrared(NIR)fluorescence imaging probe,Er-V,for monitoring ER viscosity through a molecular rotor strategy.Er-V exhibited a strong NIR fluorescence signal(at 626 nm)when the environmental viscosity hindered the rotation of the malononitrile group.Using Er-V,we successfully observed a significant enhancement in viscosity in the liver of mice with NAFLD.Therefore,this imaging method based on Er-V is expected to provide a new approach for early detection and diagnosis of NAFLD.展开更多
Background: Even though NIR fluorescence imaging has many advantages in SLN mapping and cancer detection, NIR fluorescence imaging shows a serious drawback that NIR cannot be detected by the naked eye without any dete...Background: Even though NIR fluorescence imaging has many advantages in SLN mapping and cancer detection, NIR fluorescence imaging shows a serious drawback that NIR cannot be detected by the naked eye without any detectors. This limitation further disturbs accurate SLN detection and adequate tumor resection resulting in the presence of cancerous cells near the boundaries of surgically removed tissues. Materials and methods: To overcome the drawback of the conventional NIR imaging method, we suggest a novel NIR imaging system which can make the NIR fluorescence image visible to the naked eye as NIR fluorescence image detected by a video camera is processed by a computer and then projected back onto the NIR fluorescence excitation position with a projector using conspicuous color light. Image processing techniques were used for projection onto the exact position of the NIR fluorescence image. Also, we implemented a phantom experiment to evaluate the performance of the developed NIR fluorescence projection system by use of the ICG. Results: The developed NIR fluorescence projection system was applied in normal mouse model to confirm the usefulness of the system in the clinical field. A BALB/c nude mouse was prepared to be applied in normal mouse model and 0.25 mg/ml stock solution of the ICG was injected through a tail vein of the mouse. From the application in normal mouse model, we could confirm that the injected ICG stayed in the liver of the mouse and verify that the projection system projected the ICG fluorescence image at the exact location of the ICG by performing laparotomy of the mouse. Conclusions: From the application in normal mouse model, we could verify that the ICG fluorescence image was precisely projected back on the site where ICG fluorescence generated. It can be demonstrated that the NIR fluorescence projection system can make it possible to visualize the invisible NIR fluorescence image and to realize that SLN mapping and cancer detection in clinical surgery.展开更多
Difluoroboronβ-diketonate(BF2bdk)complexes have attracted much attention due to their outstanding photophysical properties.However,BF2bdk with near-infrared fluorescence usually suffer from emission quenching in soli...Difluoroboronβ-diketonate(BF2bdk)complexes have attracted much attention due to their outstanding photophysical properties.However,BF2bdk with near-infrared fluorescence usually suffer from emission quenching in solid state due to theπ-πstacking in aggregation.Herein,we report a BF2bdk dye exhibiting donor-acceptor(D-A)structure with the difluoroboron moiety acting as the electron acceptor and the aminonaphthalene as the electron donor.It processes intense molar extinction coefficient,large Stokes shift and strong fluorescence in red/NIR region in both solution and aggregations.It was used for NIR imaging in living cells.展开更多
The absorption,scattering,and autofluorescence of biological tissues in short-wave infrared re-gion(SWIR,900-1700 nm)are relatively low,so SWIR fluorescence usually has deeper pene-tration into living tissues,and can ...The absorption,scattering,and autofluorescence of biological tissues in short-wave infrared re-gion(SWIR,900-1700 nm)are relatively low,so SWIR fluorescence usually has deeper pene-tration into living tissues,and can show a higher signal-to-noise ratio when used for imaging in vivo.However,there are few types of organic SWIR fluorescent materials currently.In this work,p-azaquinodimethane(p-AQM)with a quinoid structure is used as the acceptor unit,and car-bazole or fluorene with sp3 hybridization are used as the donor units,two conjugated polymers were synthesized.The quinone structure is conducive to the redshift of absorption and fluores-cence spectra,and the sp3 hybridization structure is conducive to weakening the aggregation quenching of polymer fluorescence.PF and PCz exhibited absorption peaks of 492 nm and 508 nm,respectively.The emission peaks of the two polymers are 920 nm and 950 nm,respec-tively,both in the short-wave near infrared region.The quantum yield(QY)of PF and PCz is 0.4%and 0.3%,respectively.展开更多
Near infrared fluorescence using indocyanine green is beneficial for visual assessment of blood vessels,blood flow,and tissue perfusion,sentinel lymph node biopsy,lymph node road mapping,identification of the vascular...Near infrared fluorescence using indocyanine green is beneficial for visual assessment of blood vessels,blood flow,and tissue perfusion,sentinel lymph node biopsy,lymph node road mapping,identification of the vascular system round the major vessels,and the detection of ureters in order to reduce the risk of iatrogenic ureteral lesions in colorectal surgery.展开更多
Introduction: Near-infrared fluorescence imaging is a technique that will establish itself in the short term at the international level because it is recognized for its potential to improve the performance of surgical...Introduction: Near-infrared fluorescence imaging is a technique that will establish itself in the short term at the international level because it is recognized for its potential to improve the performance of surgical interventions, its moderate investment and operating costs and its portability. Although the technology is now mature, there is currently the problem of the availability of contrast agents to be injected IV. The aim of this methodology article is to propose an alternative solution to the need for contrast agents for clinical research, particularly in oncology. Methodology: They consist of coupling a fluorescent marker in the form of an NHS derivative, such as IR DYE manufactured in compliance with GMP, with therapeutic monoclonal antibodies having marketing authorization for molecular imaging. For a given antibody, the marking procedure must be the subject of a validation file on the final preparation filtered on a sterilizing membrane at 0.22 μm. Once the procedure has been validated, it would be unnecessary to repeat the tests before each clinical research examination. A check of the marking by thin-layer chromatography (TLC) and place it in a sample bank at +4˚C for 1 month of each injected formulation would be sufficient for additional tests if necessary. Conclusion: Molecular near-infrared fluorescence imaging is experiencing development, the process of which could be accelerated by greater availability of clinical contrast agents. Alternative solutions are therefore necessary to promote clinical research in this area. These methods must be shared to make it easier for researchers.展开更多
基金supported by the National Natural Science Foundation of China (Nos. 81925019, 81801817 and U22A20333)the National Key Research and Development Program of China (Nos. 2023YFB3810000 and 2023YFB3810003)+1 种基金the Fundamental Research Funds for the Central Universities and the Fujian Basic Research Foundation (Nos. 2022J011403, 2023XAKJ0101009, B2302014 and 2020Y4003)the Program for New Century Excellent Talents in University, China (No. NCET-13-0502).
文摘Fluorescent probes have wide applications in biological and environmental analysis due to their advantages of simple operation, convenient flexibility, high sensitivity and efficiency. They are considered to be promising tools for accurate analysis of agriculture- and food-related hazardous substances. In this review, the types and characteristics of the near-infrared fluorescence probes (NIFPs) are briefly described. The recent advances of NIFPs for precisely detecting various hazardous substances including heavy metals, sulfite and related sulfiting agents and hydrogen peroxide are summarized. Finally, the present challenges and future perspectives faced by NIFPs in food safety analysis are discussed.
基金financially supported by the Natural Science Foundation of Jiangsu Province(Grant No.BK20241181)the State Key Laboratory of AnalyticalChemistry for Life Science,School of Chemistry and Chemical Engineering,Nanjing University(Grant No.SKLACLS2419)。
文摘Using 2-dicyanomethylene-3-cyano-4,5,5-trimethyl-2,5-dihydrofuran(TCF)as a near-infrared fluorescent chromophore,we designed and synthesized a TCF-based fluorescent probe TCF-NS by introducing 2,4-dinitrophenyl ether as the recognized site for H_(2)S.The probe TCF-NS displayed a rapid-response fluorescent against H_(2)S with high sensitivity and selection but had no significant fluorescence response to other biothiols.Furthermore,TCF-NS was applied to sense H_(2)S in living cells successfully with minimized cytotoxicity and a large Stokes shift.
基金financially supported by Guangxi Natural Science Foundation(Nos.AD21220061,2021GXNSFDA075003)National Natural Science Foundation of China(Nos.22277014,22077048)the startup fund of Guangxi University(No.A3040051003)。
文摘Rheumatoid arthritis,being a chronic autoimmune malady,may culminate in joint malformation and incapacitation in severe instances.Nevertheless,monitoring the heterogeneity of the viscosity microenvironment in local joint areas remains challenging.Hence,we have developed a near-infrared(NIR)-emitting fluorescence lifetime probe WY-V for dual fluorescence lifetime imaging microscopy(FLIM)/NIR optical imaging,featuring precise targeting capabilities to the endoplasmic reticulum(ER)and lipid droplets(LD).This probe modulates distinct fluorescence lifetimes in the varying viscosity environments of these organelles,allowing for the quantification of their respective viscosities.Using FLIM/NIR optical imaging of joint tissues from arthritic mice,the probe accurately discerned the viscosity of inflamed cells at diverse sites,reveals the viscosity heterogeneity present within the arthritic tissues.Therefore,this research offers a potent biological instrument for clinical diagnosis and pathological examination of rheumatoid arthritis.
基金supported by grants from the National Natu-ral Science Foundation of China(81302161 and 82003103)the Science and Technology Department of Sichuan Province(2021YFS0375 and 2020YJ0450).
文摘A pancreas surgeon’s constant goal is to do"less damage,more radical".Currently,a small number of highly trained surgeons opt for single-incision laparoscopic pancreaticoduodenectomy(SILPD)or single-incision plus one-port LPD(SILPD+1)to minimize post-operative pain,improve convalescence,and provide a more pleas-ing cosmetic outcome[1,2].Additionally,some skilled surgeons have claimed that laparoscopic duodenum-preserving complete pancreatic head resections(LDPPHR)result in less trauma and en-hanced quality of life[3,4].However,LDPPHR is still challenging because of its lengthy learning curve and"sword-fighting"impact.Additionally,there has not been any global reporting on the suit-ability of single-incision plus one-port DPPHR with pancreaticogas-trostomy(SILDPPHR-T+1)in place of SILPD+1.This study aimed to illustrate the SILDPPHR-T+1 procedure specifics for a patient with pancreatic head intraductal papillary mucinous neoplasm(IPMN)(main pancreatic duct type)(MD-IPMN).
文摘AIM: To investigate feasibility and accuracy of near-infrared fluorescence imaging using indocyanine green: nanocolloid for sentinel lymph node (SLN) detection in gastric cancer.METHODS: A prospective, single-institution, phase I feasibility trial was conducted. Patients suffering from gastric cancer and planned for gastrectomy were included. During surgery, a subserosal injection of 1.6 mL ICG:Nanocoll was administered around the tumor. NIR fluorescence imaging of the abdominal cavity was performed using the Mini-FLARE™ NIR fluorescence imaging system. Lymphatic pathways and SLNs were visualized. Of every detected SLN, the corresponding lymph node station, signal-to-background ratio and histopathological diagnosis was determined. Patients underwent standard-of-care gastrectomy. Detected SLNs outside the standard dissection planes were also resected and evaluated.RESULTS: Twenty-six patients were enrolled. Four patients were excluded because distant metastases were found during surgery or due to technical failure of the injection. In 21 of the remaining 22 patients, at least 1 SLN was detected by NIR Fluorescence imaging (mean 3.1 SLNs; range 1-6). In 8 of the 21 patients, tumor-positive LNs were found. Overall accuracy of the technique was 90% (70%-99%; 95%CI), which decreased by higher pT-stage (100%, 100%, 100%, 90%, 0% for respectively Tx, T1, T2, T3, T4 tumors). All NIR-negative SLNs were completely effaced by tumor. Mean fluorescence signal-to-background ratio of SLNs was 4.4 (range 1.4-19.8). In 8 of the 21 patients, SLNs outside the standard resection plane were identified, that contained malignant cells in 2 patients.CONCLUSION: This study shows successful use of ICG:Nanocoll as lymphatic tracer for SLN detection in gastric cancer. Moreover, tumor-containing LNs outside the standard dissection planes were identified.
文摘Surgery is still the primary curative treatment for gastric cancer,which includes resection of the tumor with adequate margins and extended lymphadenectomy.In order to improve the operative results and the quality of life of patients,several endeavors have been made toward precision medicine through image-guided surgery,allowing access to real-time intraoperative anatomy and accurate tumor staging.The goal of the surgeon is to achieve a more precise,individualized,and less invasive surgery without compromising oncological efficiency and safety.In this perspective,we have demonstrated the role of indocyanine green(ICG)and near-infrared(NIR)fluorescence imaging method in gastric cancer surgery.This technique may be used to improve localization of the tumor,detection of sentinel lymph nodes(SLN),real-time lymphatic mapping,and blood flow assessment(anastomosis perfusion).
基金partially sponsored by Natural Science Foundation of Hubei Province,China(No.2015CFB688)
文摘Fluorescence intraoperative cholangiography(IOC) is a potential alternative for identifying anatomical variation and preventing iatrogenic bile duct injuries by using the near-infrared probe indocyanine green(ICG). However, the dynamic process and mechanism of fluorescence IOC have not been elucidated in previous publications. Herein, the optical properties of the complex of ICG and bile, dynamic fluorescence cholangiography and iatrogenic bile duct injuries were investigated. The emission spectrum of ICG in bile peaked at 844 nm and ICG had higher tissue penetration. Extrahepatic bile ducts could fluoresce 2 min after intravenous injection, and the fluorescence intensity reached a peak at 8 min. In addition, biliary dynamics were observed owing to ICG excretion from the bile ducts into the duodenum. Quantitative analysis indicated that ICG-guided fluorescence IOC possessed a high signal to noise ratio compared to the surrounding peripheral tissue and the portal vein. Fluorescence IOC was based on rapid uptake of circulating ICG in plasma by hepatic cells, excretion of ICG into the bile and then its interaction with protein molecules in the bile. Moreover, fluorescence IOC was sensitive to detect bile duct ligation and acute bile duct perforation using ICG in rat models. All of the results indicated that fluorescence IOC using ICG is a valid alternative for the cholangiography of extrahepatic bile ducts and has potential for measurement of biliary dynamics.
基金Supported by the National High Level Hospital Clinical Research Funding,No.2022-PUMCH-B-003Beijing Technology Innovation Foundation for University or College Students,No.2022zglc06062.
文摘BACKGROUND Near-infrared fluorescence imaging via using intravenous indocyanine green(ICG)has a wide range of applications in multiple surgical scenarios.In lapa-roscopic cholecystectomy(LC),it facilitates intraoperative identification of the biliary system and reduces the risk of bile duct injury.However,the usual single color fluorescence imaging(SCFI)has limitations in manifesting the fluorescence signal of the target structure when its intensity is relatively low.Moreover,sur-geons often experience visual fatigue.We hypothesized that a novel imaging stra-tegy,named multi-color fluorescence imaging(MCFI),could potentially address these issues by decreasing hepatic and background fluorescence pollution and improving biliary visualization.AIM To investigate the novel imaging strategy MCFI in LC.METHODS This was a single-center retrospective study conducted at Peking Union Medical College Hospital,Beijing,China.Patients who underwent LC from June 2022 to March 2023 by the same surgical team were enrolled.Demographic features,clinical and surgical information were collected.The clarity,visual comfort,and effectiveness of different imaging strategies were subjectively evaluated by surgeons.RESULTS A total of 155 patients were included,60 patients were in the non-ICG group in which only bright light illuminance without ICG was applied,60 patients were in the SCFI group,and 35 patients were in the MCFI group.No statist-ically significant differences were found in demographics or clinical history.Post-surgical complications were minimal in all 3 groups with no significant differences observed.MCFI improved the clarity of imaging and visual comfort.Clarity of imaging and visual comfort were improved with MCFI.CONCLUSION MCFI improves biliary visualization and reduces liver fluorescence contamination,which supports its routine use in LC.MCFI may also be a better choice than SCFI in other clinical settings.
基金supported by the Medical and Health Research Project of Zhejiang Province(2018RC008,2018KY113,and WKJ-ZJ-2125)Zhejiang Provincial Natural Science Foundation(LQ20H040011).
文摘Objective:Laparoscopic pelvic lymph node dissection(LPND),which is an effective therapy for endometrial cancer,is challenging because of the complexity of the procedure and the occurrence of postoperative complications.This study aimed to explore whether indocyanine green(ICG)-enhanced nearinfrared(NIR)fluorescence-guided LPND is superior to LPND in the context of early-stage endometrial carcinoma.Methods:In this retrospective study,we included the medical records of 190 patients with early-stage endometrioid adenocarcinoma who underwent LPND at the Department of Obstetrics and Gynecology,Sir Run Run Shaw Hospital,Zhejiang University School of Medicine between January 2019 and January 2021.Depending on whether ICG-enhanced NIR fluorescence guidance was used,the patients were assigned to the ICG group or non-ICG group.Patients were followed-up for one year after surgery.Data on demographic characteristics,pathological results,operative outcomes,and complications were collected and analyzed.Results:The baseline characteristics were comparable between the ICG group and non-ICG group,including age,BMI,pregnancy history,and preoperative hemoglobin.For surgical outcomes,the patients in ICG group had significantly lower intraoperative blood loss(50 mL vs.120 mL,p<0.001),less postoperative pelvic drainage time(4.14±1.44 d vs.5.70±1.89 d,p¼0.001),shorter duration of hospital stay(5.26±1.41 d vs.7.37±1.85 d,p¼0.003),higher number of positive pelvic lymph nodes(PLNs)(1 vs.0,p¼0.003),and more PLN-positive cases(16.0%vs.3.6%,p¼0.003)than the patients in non-ICG group.However,no significant differences were noted in blood transfusion requirement,operative time,hemoglobin level decreases,number of PLNs harvested,or the presence of lymphocysts between the two groups.Conclusion:Our study showed that ICG-enhanced NIR fluorescence-guided operation may improve the accuracy and safety of LPND.
基金supported by the National Key Research and Development Program of China (No.2016YFA0201400)National Natural Science Foundation of China (No. 81671431)
文摘Objective: To evaluate the imaging potential of a novel near-infrared(NIR) probe conjugated to COC183 B2 monoclonal antibodies(MAb) in ovarian cancer(OC).Methods: The expression of OC183 B2 antigen in OC was determined by immunohistochemical(IHC) staining using tissue microarrays with the H-score system and immunofluorescence(IF) staining of tumor cell lines.Imaging probes with the NIR fluorescent dye cyanine 7(Cy7) conjugated to COC183 B2 Mab were chemically engineered. OC183 B2-positive human OC cells(SKOV3-Luc) were injected subcutaneously into BALB/c nude mice. Bioluminescent imaging(BLI) was performed to detect tumor location and growth. COC183 B2-Cy7 at 1.1,3.3, 10, or 30 μg were used for in vivo fluorescence imaging, and phosphate-buffered saline(PBS), free Cy7 dye and mouse isotype immunoglobulin G(IgG)-Cy7(delivered at the same doses as COC183 B2-Cy7) were used as controls.Results: The expression of OC183 B2 with a high H-score was more prevalent in OC tissue than fallopian tube(FT) tissue. Among 417 OC patients, the expression of OC183 B2 was significantly correlated with the histological subtype, histological grade, residual tumor size, relapse state and survival status. IF staining demonstrated that COC183 B2 specifically expressed in SKOV3 cells but not HeLa cells. In vivo NIR fluorescence imaging indicated that COC183 B2-Cy7 was mainly distributed in the xenograft and liver with optimal tumor-to-background(T/B)ratios in the xenograft at 30 μg dose. The highest fluorescent signals in the tumor were observed at 96 h postinjection(hpi). Ex vivo fluorescence imaging revealed the fluorescent signals mainly from the tumor and liver. IHC analysis confirmed that xenografts were OC183 B2 positive.Conclusions: COC183 B2 is a good candidate for NIR fluorescence imaging and imaging-guided surgery in OC.
基金supported financially by the National Natural Science Foundation of China (Nos. 21421005, 21576038)the Fundamental Research Funds for the Central Universities of China (No. DUT16TD21)Science Program of Dalian City (Nos. 2014J11JH133, 2015J12JH207)
文摘Imaging hypoxia using fluorescence probes for nitroreductase(NTR) have attracted much attention in last decade. At least three different linkers have been commonly used to connect the recognition unit and reporting unit in reported probes for NTR. Meanwhile, the linker is known to be a key factor for achieving best sensing performance. In this work, three near-infrared fluorescence probes CyNP-1, CyNP-2 and CyNP-3 were designed and synthesized from an aminocyanine dye CyNP. The three probes have the same recognition unit and same fluorescence reporting unit, but different linkers. CyNP-1 was found to have the best sensing performance for NTR with 40-fold of fluorescence enhancement. It is well investigated how the difference of the linkers brings out the different sensing performance by HPLC, MS and docking calculations. In the end, CyNP-1 was found to have good selectivity for NTR and used to imaging hypoxia in Hela cells.
基金Supported by (in part) NIH grant R01-CA-115296the Dutch Cancer Society grant UL2010-4732the Center for Trans-lational Molecular Medicine, project MUSIS (grant 03O-202)
文摘A 67-year-old female presented with unexplained abdominal pain. A contrast-enhanced computed tomography scan of the abdomen incidentally revealed a mass in the uncinate process of the pancreas. This mass was resected and based on histopathological findings, diagnosed as a solitary fibrous tumor (SFT) of the pancreas. A SFT is an extremely rare benign mesenchymal tumor that in 65% of cases affects the visceral pleura but can also affect extra-pleural sites. The intraoperative demarcation of pancreatic tumors, such as SFTs, can bechallenging. In this report, the first clear intraoperative identification of a SFT of the pancreas in a human was shown using near-infrared fluorescence and methylene blue.
基金"Kom op tegen Kanker"(Stand up to Cancer),the Flemish cancer society
文摘BACKGROUND After an esophagectomy, the stomach is most commonly used to restore continuity of the upper gastrointestinal tract. These esophago-gastric anastomoses are prone to serious complications such as leakage associated with high morbidity and mortality. Graft perfusion is considered to be an important predictor for anastomotic integrity. Based on the current literature we believe Indocyanine green fluorescence angiography(ICGA) is an easy assessment tool for gastric tube(GT) perfusion, and it might predict anastomotic leakage(AL).AIM To evaluate feasibility and effectiveness of ICGA in GT perfusion assessment and as a predictor of AL.METHODS This study was designed according to the PRISMA guidelines and registered in the PROSPERO database. PubMed and EMBASE were independently searched by 2 reviewers for studies presenting data on intraoperative ICGA GT perfusion assessment during esophago-gastric reconstruction after esophagectomy.Relevant outcomes such as feasibility, complications, intraoperative surgical changes based on ICGA findings, quantification attempts, anatomical data and the impact of ICGA on postoperative anastomotic complications, were collected by 2 independent researchers. The quality of the included articles was assessed based on the Methodological Index for Non-Randomized Studies. The 19 included studies presented data on 1192 esophagectomy patients, in 758 patients ICGA was used perioperative to guide esophageal reconstruction.RESULTS The 19 included studies for qualitative analyses all described ICGA as a safe and easy method to evaluate gastric graft perfusion. AL occurred in 13.8% of the entire cohort, 10% in the ICG guided group and 20.6% in the control group(P <0.001). When poorly perfused cases are excluded from the analyses, the difference in AL was even larger(AL well-perfused group 6.3% vs control group 20.5%, P <0.001). The AL rate in the group with an altered surgical plan based on the ICG image was 6.5%, similar to the well perfused group(6.3%) and significantly less than the poorly perfused group(47.8%)(P < 0.001), suggesting that the technique is able to identify and alter a potential bad outcome.CONCLUSION ICGA is a safe, feasible and promising method for perfusion assessment. The lower AL rate in the well perfused group suggest that a good fluorescent signal predicts a good outcome.
文摘Near-infrared fluorescence(NIRF)is a technique of augmented reality that,when applied in the operating theatre,allows the colorectal surgeon to visualize and assess bowel vascularization,to identify lymph nodes draining a cancer site and to identify ureters.Herein,we review the literature regarding NIRF in colorectal surgery.
基金supported by the National Natural Science Foundation of China(Nos.21927811,91753111,22074083,21907061)the Key Research and Development Program of Shandong Province(No.2018YFJH0502)the National Major Scientific and Technological Special Project for"Significant New Drugs Development"(No.2017ZX09301030004).
文摘Nonalcoholic fatty liver disease(NAFLD)can cause serious liver damage.Early diagnosis and effective treatment of NAFLD can greatly improve treatment rates.The initiation and development of NAFLD has been closely linked to endoplasmic reticulum(ER)stress,which might cause ER viscosity variations.Therefore,if the internal relationship between ER viscosity and NAFLD is clarified,an effective approach for early diagnosis may result.Herein,we fabricated a novel near-infrared(NIR)fluorescence imaging probe,Er-V,for monitoring ER viscosity through a molecular rotor strategy.Er-V exhibited a strong NIR fluorescence signal(at 626 nm)when the environmental viscosity hindered the rotation of the malononitrile group.Using Er-V,we successfully observed a significant enhancement in viscosity in the liver of mice with NAFLD.Therefore,this imaging method based on Er-V is expected to provide a new approach for early detection and diagnosis of NAFLD.
文摘Background: Even though NIR fluorescence imaging has many advantages in SLN mapping and cancer detection, NIR fluorescence imaging shows a serious drawback that NIR cannot be detected by the naked eye without any detectors. This limitation further disturbs accurate SLN detection and adequate tumor resection resulting in the presence of cancerous cells near the boundaries of surgically removed tissues. Materials and methods: To overcome the drawback of the conventional NIR imaging method, we suggest a novel NIR imaging system which can make the NIR fluorescence image visible to the naked eye as NIR fluorescence image detected by a video camera is processed by a computer and then projected back onto the NIR fluorescence excitation position with a projector using conspicuous color light. Image processing techniques were used for projection onto the exact position of the NIR fluorescence image. Also, we implemented a phantom experiment to evaluate the performance of the developed NIR fluorescence projection system by use of the ICG. Results: The developed NIR fluorescence projection system was applied in normal mouse model to confirm the usefulness of the system in the clinical field. A BALB/c nude mouse was prepared to be applied in normal mouse model and 0.25 mg/ml stock solution of the ICG was injected through a tail vein of the mouse. From the application in normal mouse model, we could confirm that the injected ICG stayed in the liver of the mouse and verify that the projection system projected the ICG fluorescence image at the exact location of the ICG by performing laparotomy of the mouse. Conclusions: From the application in normal mouse model, we could verify that the ICG fluorescence image was precisely projected back on the site where ICG fluorescence generated. It can be demonstrated that the NIR fluorescence projection system can make it possible to visualize the invisible NIR fluorescence image and to realize that SLN mapping and cancer detection in clinical surgery.
基金financially supported by National Natural Science Foundation of China(No.21525206)
文摘Difluoroboronβ-diketonate(BF2bdk)complexes have attracted much attention due to their outstanding photophysical properties.However,BF2bdk with near-infrared fluorescence usually suffer from emission quenching in solid state due to theπ-πstacking in aggregation.Herein,we report a BF2bdk dye exhibiting donor-acceptor(D-A)structure with the difluoroboron moiety acting as the electron acceptor and the aminonaphthalene as the electron donor.It processes intense molar extinction coefficient,large Stokes shift and strong fluorescence in red/NIR region in both solution and aggregations.It was used for NIR imaging in living cells.
基金supported by the National Natural Science Foundation of China(Grant Nos.21807062 and 21976099)the Shandong Provincial Natural Science Foundation(ZR2018BB014)+3 种基金the Department of Science and Technology of Shan-dong Province(2019GGX102020)the Source In-novation Project of Qingdao(171183jch)Qingdao Postdoctoral Applied Research Project(2018111)National College Students Innovation and En-trepreneurship Training Program(201910429007)
文摘The absorption,scattering,and autofluorescence of biological tissues in short-wave infrared re-gion(SWIR,900-1700 nm)are relatively low,so SWIR fluorescence usually has deeper pene-tration into living tissues,and can show a higher signal-to-noise ratio when used for imaging in vivo.However,there are few types of organic SWIR fluorescent materials currently.In this work,p-azaquinodimethane(p-AQM)with a quinoid structure is used as the acceptor unit,and car-bazole or fluorene with sp3 hybridization are used as the donor units,two conjugated polymers were synthesized.The quinone structure is conducive to the redshift of absorption and fluores-cence spectra,and the sp3 hybridization structure is conducive to weakening the aggregation quenching of polymer fluorescence.PF and PCz exhibited absorption peaks of 492 nm and 508 nm,respectively.The emission peaks of the two polymers are 920 nm and 950 nm,respec-tively,both in the short-wave near infrared region.The quantum yield(QY)of PF and PCz is 0.4%and 0.3%,respectively.
文摘Near infrared fluorescence using indocyanine green is beneficial for visual assessment of blood vessels,blood flow,and tissue perfusion,sentinel lymph node biopsy,lymph node road mapping,identification of the vascular system round the major vessels,and the detection of ureters in order to reduce the risk of iatrogenic ureteral lesions in colorectal surgery.
文摘Introduction: Near-infrared fluorescence imaging is a technique that will establish itself in the short term at the international level because it is recognized for its potential to improve the performance of surgical interventions, its moderate investment and operating costs and its portability. Although the technology is now mature, there is currently the problem of the availability of contrast agents to be injected IV. The aim of this methodology article is to propose an alternative solution to the need for contrast agents for clinical research, particularly in oncology. Methodology: They consist of coupling a fluorescent marker in the form of an NHS derivative, such as IR DYE manufactured in compliance with GMP, with therapeutic monoclonal antibodies having marketing authorization for molecular imaging. For a given antibody, the marking procedure must be the subject of a validation file on the final preparation filtered on a sterilizing membrane at 0.22 μm. Once the procedure has been validated, it would be unnecessary to repeat the tests before each clinical research examination. A check of the marking by thin-layer chromatography (TLC) and place it in a sample bank at +4˚C for 1 month of each injected formulation would be sufficient for additional tests if necessary. Conclusion: Molecular near-infrared fluorescence imaging is experiencing development, the process of which could be accelerated by greater availability of clinical contrast agents. Alternative solutions are therefore necessary to promote clinical research in this area. These methods must be shared to make it easier for researchers.