With the increasing demand for high reliability and availability in power conversion equipment within power electronics systems,the fault diagnosis of neutral-point-clamped(NPC) three-level inverters has garnered wide...With the increasing demand for high reliability and availability in power conversion equipment within power electronics systems,the fault diagnosis of neutral-point-clamped(NPC) three-level inverters has garnered widespread attention.To address the challenges of fault feature extraction,this article proposes an end-to-end diagnostic approach based on a wavelet kernel convolutional neural network (WKCNN),capable of extracting multi-scale features from current signals to significantly enhance diagnostic accuracy.This method directly uses raw three-phase current signals as input,applying wavelet kernel convolution to automatically capture frequency-domain fault features,combined with a Softmax classifier optimized by the Adam algorithm to achieve fault diagnosis for NPC threelevel inverters.Experimental results under various operating conditions demonstrate that this approach maintains robust diagnostic accuracy across multiple fault scenarios,with comparative analysis further confirming its advantages in diagnostic efficiency and performance over traditional machine learning and other deep learning methods.展开更多
The output current harmonic distortion of a three-level inverter is less than the traditional twolevel inverter.The voltage stress of the semiconductor switch is low.A neutral point potential drift control method is p...The output current harmonic distortion of a three-level inverter is less than the traditional twolevel inverter.The voltage stress of the semiconductor switch is low.A neutral point potential drift control method is proposed to solve the problem of the neutral point potential drift of the three-level inverter.The interaction mechanism between the neutral point potential and the space voltage vector is presented.The small vector output by the inverter is found to be the root cause of the midpoint potential drift.It is found that the fluctuation of the midpoint potential could be suppressed by increasing the capacitance value of the inverter bus voltage stabilizing capacitor.Furthermore,it inhibits the fluctuation of the midpoint potential.The experimental results verify the efficiency and precision of the proposed method.展开更多
This paper presents a method for estimating the parameters of DC-link capacitors in three-level NPC voltage source inverters(3L-NPC-VSI)used in grid-tied systems.The technique uses the signals generated by the intermo...This paper presents a method for estimating the parameters of DC-link capacitors in three-level NPC voltage source inverters(3L-NPC-VSI)used in grid-tied systems.The technique uses the signals generated by the intermodulation caused by the PWM strategy and converter topology interaction to estimate the capacitor parameters of the converter DC-link.It utilizes an observer-based structure consisting of a recursive noninteger sliding discrete Fourier transform(rnSDFT)and an RLS filter improved with a forgetting factor(oSDFT-RLS)to accurately estimate the capacitance and equivalent series resistance(ESR).Importantly,this method does not require additional sensors beyond those already installed in off-the-shelf 3L-NPC-VSI systems,ensuring its noninvasiveness.Furthermore,the oSDFTRLS estimates capacitor parameters in the time-frequency domain,enabling the tracking of capacitor degradation and predicting potential faults.Experimental results from the laboratory setup demonstrate the effectiveness of the proposed condition monitoring method.展开更多
中点钳位(neutral point clamped,NPC)型三电平逆变器并网工作环境恶劣,IGBT面临单管与双管同时故障的挑战,这使得故障特征之间的差异变得非常微弱,进而导致双管故障的识别精度难以有效提升。为此,提出了一种新的故障诊断方法,该方法结...中点钳位(neutral point clamped,NPC)型三电平逆变器并网工作环境恶劣,IGBT面临单管与双管同时故障的挑战,这使得故障特征之间的差异变得非常微弱,进而导致双管故障的识别精度难以有效提升。为此,提出了一种新的故障诊断方法,该方法结合了多通道的二维递归融合图和轻量化多尺度残差(lightweightmultiscale convolutional residuals,LMCR)网络。首先,通过仿真获取三相电流信号作为故障信号;再利用递归图(recurrence plot,RP)将三相电流信号分别转化为二维图并进行多通道融合,以捕捉时间序列中的周期性、突变点和趋势等特征;最后,将递归融合图作为输入,输入到LMCR模型中进行故障识别,LMCR模型整合多级Inception结构和残差网络,用于提取不同尺度的特征并融合这些特征,从而保证网络的梯度消失和爆炸。实验结果显示,该方法在IGBT故障识别中表现出色,无噪声环境下平均识别准确率达100%,噪声环境中也达到了92.53%,充分证明了该方法具有较强的特征提取能力和优异的抗噪性能。展开更多
This paper proposes a high performance three-level inverter Neutral Point Clamped (NPC) structure for photovoltaic system. The proposed configuration which can boost the low voltage of photovoltaic (PV) array, can als...This paper proposes a high performance three-level inverter Neutral Point Clamped (NPC) structure for photovoltaic system. The proposed configuration which can boost the low voltage of photovoltaic (PV) array, can also convert the photovoltaic DC power into high quality AC power. Attention has been paid to the problem of neutral point potential variation. In this way, a Direct Torque Control (DTC) technique has been applied and the estimated value of the Neutral Point Potential (NPP) is used, which is calculated by motor currents. This control strategy uses the redundancy presented by the inverter for selecting appropriate switching state through a switching table to achieve the control of NPP. This study shows the effect of the stability problem of the DC voltages and good static and dynamic performances were obtained in simulation of the proposed cascade “photovoltaic cell-three-level NPC VSI-induction motor”.展开更多
A comprehensive predictive strategy was proposed for the neutral-point balancing control of back-to-back three-level converters. The phase currents at both sides and the DC-link capacitor voltages were measured for th...A comprehensive predictive strategy was proposed for the neutral-point balancing control of back-to-back three-level converters. The phase currents at both sides and the DC-link capacitor voltages were measured for the prediction of the neutral-point current. A quality function was found to balance the neutral-point, and a metabolic on-times distribution factor was used as a predicator to minimize the quality function at each switching state. Simulation results show that the proposed method produces smaller ripples in tested signals compared with the established one, namely, 9.15% less in a total harmonic distortion(THD) of line-to-line voltage, 1.08% less in the THD of phase current, and 0.9 V less in the ripple of the neutral-point voltage. The obtained experimental results show that the main harmonics of the line-to-line voltage and the phase current in the proposed method are improved by 10 d B and 6 d B, respectively, and the ripple of neutral-point voltage is halved compared to the established one.展开更多
基金supported in part by Zhejiang Provincial“Pioneer”and“Leading Goose”R&D Program of China under Grant 2024C01014the National Natural Science Foundation of China under Grant52177055。
文摘With the increasing demand for high reliability and availability in power conversion equipment within power electronics systems,the fault diagnosis of neutral-point-clamped(NPC) three-level inverters has garnered widespread attention.To address the challenges of fault feature extraction,this article proposes an end-to-end diagnostic approach based on a wavelet kernel convolutional neural network (WKCNN),capable of extracting multi-scale features from current signals to significantly enhance diagnostic accuracy.This method directly uses raw three-phase current signals as input,applying wavelet kernel convolution to automatically capture frequency-domain fault features,combined with a Softmax classifier optimized by the Adam algorithm to achieve fault diagnosis for NPC threelevel inverters.Experimental results under various operating conditions demonstrate that this approach maintains robust diagnostic accuracy across multiple fault scenarios,with comparative analysis further confirming its advantages in diagnostic efficiency and performance over traditional machine learning and other deep learning methods.
基金the National Natural Science Foundation of China(No.51407007)。
文摘The output current harmonic distortion of a three-level inverter is less than the traditional twolevel inverter.The voltage stress of the semiconductor switch is low.A neutral point potential drift control method is proposed to solve the problem of the neutral point potential drift of the three-level inverter.The interaction mechanism between the neutral point potential and the space voltage vector is presented.The small vector output by the inverter is found to be the root cause of the midpoint potential drift.It is found that the fluctuation of the midpoint potential could be suppressed by increasing the capacitance value of the inverter bus voltage stabilizing capacitor.Furthermore,it inhibits the fluctuation of the midpoint potential.The experimental results verify the efficiency and precision of the proposed method.
基金funded by the Brazilian National Council for Scientific and Technological Development—CNPq(CNPq grant number 405997/2022-1)supported by the EMBRAPII VIRTUS Competence Center in Intelligent Hardware for Industry—VIRTUS-CC(MCTI grant number 055/2023).
文摘This paper presents a method for estimating the parameters of DC-link capacitors in three-level NPC voltage source inverters(3L-NPC-VSI)used in grid-tied systems.The technique uses the signals generated by the intermodulation caused by the PWM strategy and converter topology interaction to estimate the capacitor parameters of the converter DC-link.It utilizes an observer-based structure consisting of a recursive noninteger sliding discrete Fourier transform(rnSDFT)and an RLS filter improved with a forgetting factor(oSDFT-RLS)to accurately estimate the capacitance and equivalent series resistance(ESR).Importantly,this method does not require additional sensors beyond those already installed in off-the-shelf 3L-NPC-VSI systems,ensuring its noninvasiveness.Furthermore,the oSDFTRLS estimates capacitor parameters in the time-frequency domain,enabling the tracking of capacitor degradation and predicting potential faults.Experimental results from the laboratory setup demonstrate the effectiveness of the proposed condition monitoring method.
文摘This paper proposes a high performance three-level inverter Neutral Point Clamped (NPC) structure for photovoltaic system. The proposed configuration which can boost the low voltage of photovoltaic (PV) array, can also convert the photovoltaic DC power into high quality AC power. Attention has been paid to the problem of neutral point potential variation. In this way, a Direct Torque Control (DTC) technique has been applied and the estimated value of the Neutral Point Potential (NPP) is used, which is calculated by motor currents. This control strategy uses the redundancy presented by the inverter for selecting appropriate switching state through a switching table to achieve the control of NPP. This study shows the effect of the stability problem of the DC voltages and good static and dynamic performances were obtained in simulation of the proposed cascade “photovoltaic cell-three-level NPC VSI-induction motor”.
基金Project(61074018)supported by the National Natural Science Foundation of ChinaProject(2012kfjj06)supported by Hunan Province Key Laboratory of Smart Grids Operation and Control(Changsha University of Science and Technology),China
文摘A comprehensive predictive strategy was proposed for the neutral-point balancing control of back-to-back three-level converters. The phase currents at both sides and the DC-link capacitor voltages were measured for the prediction of the neutral-point current. A quality function was found to balance the neutral-point, and a metabolic on-times distribution factor was used as a predicator to minimize the quality function at each switching state. Simulation results show that the proposed method produces smaller ripples in tested signals compared with the established one, namely, 9.15% less in a total harmonic distortion(THD) of line-to-line voltage, 1.08% less in the THD of phase current, and 0.9 V less in the ripple of the neutral-point voltage. The obtained experimental results show that the main harmonics of the line-to-line voltage and the phase current in the proposed method are improved by 10 d B and 6 d B, respectively, and the ripple of neutral-point voltage is halved compared to the established one.