期刊文献+
共找到285篇文章
< 1 2 15 >
每页显示 20 50 100
MXene Nanosheet-enhanced Ionotronic Hydrogels for Wireless Powering and Noncontact Sensing
1
作者 Yao-Qian Han Zhou-Yue Lei Pei-Yi Wu 《Chinese Journal of Polymer Science》 2025年第4期572-580,共9页
Smart actuators and wearable and implantable devices have attracted much attention in healthcare and environmental sensing.Flexible electronic and ionic materials are the two main approaches used to construct these de... Smart actuators and wearable and implantable devices have attracted much attention in healthcare and environmental sensing.Flexible electronic and ionic materials are the two main approaches used to construct these devices.Among them,hydrogel-based ionic materials offer unique advantages,such as biocompatibility and adaptable mechanical properties.However,ionic hydrogels encounter challenges in achieving wirelessly powered and noncontact sensing.To address this,we introduce MXene nanosheets to construct ionotronic hydrogels.Leveraging the rich surface charges and electronic conductivity of MXene nanosheets,ionotronic hydrogels can harvest vibrational and electromagnetic waves as electrical energy and enable noncontact sensing.Under ultrasound,it can continuously generate voltages up to 85 V and light up lightemitting diodes,promising wireless charging of implanted devices.In addition,it achieves an absorption coefficient of 0.2 for 915 MHz electromagnetic waves,enabling noncontact sensing through radio frequency identification.Notably,the physically crosslinked network of the MXenebased hydrogels maintained structural and performance stability under ultrasonic stimulation and exhibited self-healing properties.Even when cut into two halves,the self-healing hydrogel fully regenerates its original performance.This study provides insight into the development of ionotronic hydrogels for wirelessly powered and noncontact sensing in smart actuators and wearable and implantable applications. 展开更多
关键词 HYDROGELS lonotronics MXene nanosheets Energy harvesting noncontact sensing
原文传递
Multifunctional Flexible Humidity Sensor Systems Towards Noncontact Wearable Electronics 被引量:16
2
作者 Yuyao Lu Geng Yang +2 位作者 Yajing Shen Huayong Yang Kaichen Xu 《Nano-Micro Letters》 SCIE EI CAS CSCD 2022年第9期187-220,共34页
In the past decade,the global industry and research attentions on intelligent skin-like electronics have boosted their applications in diverse fields including human healthcare,Internet of Things,human–machine interf... In the past decade,the global industry and research attentions on intelligent skin-like electronics have boosted their applications in diverse fields including human healthcare,Internet of Things,human–machine interfaces,artificial intelligence and soft robotics.Among them,flexible humidity sensors play a vital role in noncontact measurements relying on the unique property of rapid response to humidity change.This work presents an overview of recent advances in flexible humidity sensors using various active functional materials for contactless monitoring.Four categories of humidity sensors are highlighted based on resistive,capacitive,impedance-type and voltage-type working mechanisms.Furthermore,typical strategies including chemical doping,structural design and Joule heating are introduced to enhance the performance of humidity sensors.Drawing on the noncontact perception capability,human/plant healthcare management,human-machine interactions as well as integrated humidity sensor-based feedback systems are presented.The burgeoning innovations in this research field will benefit human society,especially during the COVID-19 epidemic,where cross-infection should be averted and contactless sensation is highly desired. 展开更多
关键词 Flexible electronics Flexible humidity sensors noncontact detection Healthcare monitoring Human-machine interactions COVID-19 epidemic
在线阅读 下载PDF
Wall slip behavior of cemented paste backfill slurry during pipeline based on noncontact experimental detection 被引量:3
3
作者 Zhenlin Xue Haikuan Sun +2 位作者 Deqing Gan Zepeng Yan Zhiyi Liu 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2023年第8期1515-1523,共9页
Wall slip is a microscopic phenomenon of cemented paste backfill(CPB)slurry near the pipe wall,which has an important influence on the form of slurry pipe transport flow and velocity distribution.Directly probing the ... Wall slip is a microscopic phenomenon of cemented paste backfill(CPB)slurry near the pipe wall,which has an important influence on the form of slurry pipe transport flow and velocity distribution.Directly probing the wall slip characteristics using conventional experimental methods is difficult.Therefore,this paper established a noncontact experimental platform for monitoring the microscopic slip layer of CPB pipeline transport independently based on particle image velocimetry(PIV)and analyzed the effects of slurry temperature,pipe diameter,solid concentration,and slurry flow on the wall slip velocity of the CPB slurry,which refined the theory of the effect of wall slip characteristics on pipeline transport.The results showed that the CPB slurry had an extensive slip layer at the pipe wall with significant wall slip.High slurry temperature improved the degree of particle Brownian motion within the slurry and enhanced the wall slip effect.Increasing the pipe diameter was not conducive to the formation of the slurry slip layer and led to a transition in the CPB slurry flow pattern.The increase in the solid concentration raised the interlayer shear effect of CPB slurry flow and the slip velocity.The slip velocity value increased from 0.025 to 0.056 m·s^(-1)when the solid content improved from 55wt%to 65wt%.When slurry flow increased,the CPB slurry flocculation structure changed,which affected the slip velocity,and the best effect of slip layer resistance reduction was achieved when the transported flow rate was 1.01 m^(3)·h^(-1).The results had important theoretical significance for improving the stability and economy of the CPB slurry in the pipeline. 展开更多
关键词 particle image velocimetry cemented paste backfill noncontact experimental platform wall slip behavior pipeline transportation
在线阅读 下载PDF
Experimental study of noncontact ultrasonic motor with non-symmetrical electrode
4
作者 杨斌 刘景全 +2 位作者 陈迪 周伟民 蔡炳初 《Chinese Physics B》 SCIE EI CAS CSCD 2006年第2期454-459,共6页
We have proposed a novel noncontact ultrasonic motor based on non-syinmetrical electrode driving. The configuration of this electrode and the fabrication process of rotors are presented. Its vibration characteristics ... We have proposed a novel noncontact ultrasonic motor based on non-syinmetrical electrode driving. The configuration of this electrode and the fabrication process of rotors are presented. Its vibration characteristics are computed and analysed by using the finite element method and studied experimentally. Good agreement between them is obtained. Moreover, it is also shown that this noncontact ultrasonic motor is operated in antisymmetric radial vibration mode of B21 mode. The maximum revolution speed for three-blade and six-blade rotors are 5100 and 3700r/min at an input voltage of 20V, respectively. Also, the noncontact high-speed revolution of the rotors can be realized by the parts of Ⅰ, Ⅲ of the electrode or Ⅱ, Ⅳ of the electrode. The levitation distance between the s tator and rotor is about 140μm according to the theoretical calculation and the experimental measurement. 展开更多
关键词 non-symmetrical electrode noncontact travelling wave ultrasonic motor
原文传递
Effects of baffie and intraocular pressure on aerosols generated in the noncontact tonometer measurement during COVID-19
5
作者 Yuan Tang Yan-Yan Chen +7 位作者 Chun-Chun Li Zhang-Yan Chen Chen Chen Si-Qi Wen Xiao-Qiong Huang Jia Qu Yan-Miao Chen Ai-Ai Chen 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2022年第4期533-540,共8页
AIM: To investigate the effects of baffle and intraocular pressure(IOP) on the aerosols generated in the noncontact tonometer(NCT) measurement and provide recommendations for the standardized use of the NCT during cor... AIM: To investigate the effects of baffle and intraocular pressure(IOP) on the aerosols generated in the noncontact tonometer(NCT) measurement and provide recommendations for the standardized use of the NCT during coronavirus disease 2019(COVID-19). METHODS: This clinical trial included 252 subjects(312 eyes) in The Eye Hospital, Wenzhou Medical University from March 7, 2020, to March 28, 2020. Sixty subjects(120 eyes) with normal IOP were divided into two groups. One group used an NCT without a baffle, another group used an NCT with a baffle. Another 192 subjects(192 eyes) were divided into four groups: Group A;(without a baffle+normal IOP), Group A;(without a baffle+high IOP), Group B;(with a baffle+normal IOP) and Group B;(with a baffle+high IOP). Particulate matter(PM) 2.5 and PM10 generated by all subjects were quantified during the NCT measurement. The IOP values were recorded simultaneously. Effects of baffle and IOP on aerosols generated during the NCT measurement were analyzed.RESULTS: In the normal eye group with a baffle, the aerosol density decreased in a wave-like shape near the NCT with the increase in the number of people measured for IOP, demonstrating no cumulative effect. However, in the normal eye group without a baffle, there was a cumulative effect. PM2.5 and PM10 in Group A;were higher than Group A;(both P<0.001). The PM2.5 and PM10 in Group B;were higher than Group B;(P<0.01, P<0.001 respectively). The PM10 of Group B;was lower than Group A;(P<0.01). PM2.5 in Group B;were lower than Group A;(P<0.01). The median of per capita PM2.5 and PM10 in the combined Group A;+A;were 0.80 and 1.10 μg/m;respectively, which were higher than 0.20 and 0.60 μg/m;in the combined Group B;+B;(both P<0.01). The median of per capita PM2.5 and PM10 in the combined Group A;+B;were 0.10 and 0.20 μg/m;respectively, which were lower than 1.30 and 1.70 μg/m;in the combined Group A;+B;(both P<0.001).CONCLUSION: More aerosols could be generated in patients with high IOP. After the NCT is equipped with a baffle, per capita aerosol density generated decreased significantly near the NCT;And with the increase in the number of people measured for IOP, the aerosols gradually dissipated near the NCT, demonstrating no cumulative effect. Therefore, it is suggested that the NCT should be equipped with a baffle, especially for patients with high IOP. 展开更多
关键词 noncontact tonometry aerosol BAFFLE intraocular pressure coronavirus disease 2019
原文传递
Noncontact Driving System Using Induction-Based Method and Integrated Piezoelectric Ultrasonic Transducers
6
作者 Riichi Murayama Makiko Kobayashi +1 位作者 Kuo-Ting Wu Cheng-Kuei Jen 《Journal of Sensor Technology》 2012年第2期60-67,共8页
Integrated Ultrasonic Transducers (IUTs) have been developed for high-temperature nondestructive evaluation applications. In many field, it would be helpful if a pipe covered by a protective layer of about 10 cm thick... Integrated Ultrasonic Transducers (IUTs) have been developed for high-temperature nondestructive evaluation applications. In many field, it would be helpful if a pipe covered by a protective layer of about 10 cm thickness, which is under operation at several hundred Celsius, could be inspected from above the protective layer by an IUT. As a first step toward achieving the inspection of such a pipeline, an induction-based method using coils is presented together with IUTs. This study focuses on the effects of the separation distance (liftoff) between the coils on the ultrasonic signal strength and bandwidth of the IUTs. Ultrasonic signals were generated and received by the IUTs on a steel plate with a sufficient strength for thickness measurements when the liftoff was 20 cm. It was also shown that a ferrite disc together with the coils enhanced the received signal strength even when the liftoff was over 10 cm. 展开更多
关键词 ULTRASONIC Wave noncontact Sensing INTEGRATED ULTRASONIC TRANSDUCER Electromagnetic INDUCTION LAW
暂未订购
Performance of Array-Type Noncontact End Gripper Based on Coanda Mechanism for Gripping Garment Fabrics
7
作者 LI Hansen LI Xinrong +2 位作者 LIU Hanbang LI Xingxing LI Yuzhuo 《Journal of Donghua University(English Edition)》 CAS 2022年第5期435-440,共6页
To increase the gripping area of noncontact end grippers(NCEGs), an array-type NCEG based on the Coanda mechanism is proposed, and its performance in gripping different garment fabrics(GFs) is studied. Firstly, the st... To increase the gripping area of noncontact end grippers(NCEGs), an array-type NCEG based on the Coanda mechanism is proposed, and its performance in gripping different garment fabrics(GFs) is studied. Firstly, the structure and the working mechanism of a single Coanda-based NCEG were analyzed. Secondly, four such grippers were arranged in array to form a minimum gripping unit. Then, the structure of the connecting plate(CP) to the gripper was optimized by simulation analysis to exclude airflow interference, and the adsorption performance of GFs with different fabric parameters was measured. Finally, the experimental results were analyzed to verify the scientific validity and the feasibility of the array-type arrangement. The results show that compared with other NCEGs, the array-type ones based on the Coanda mechanism are better at gripping various large-area GFs and offer better adsorption performance. This innovation provides a new solution to the problem of insufficient gripping area in GF gripping and is very important for improving the production efficiency of garment processing. 展开更多
关键词 noncontact end gripping array-type arrangement garment fabric(GF) adsorption performance Coanda mechanism
在线阅读 下载PDF
A Single-Finger Operated Noncontact User Interface
8
作者 Hiroki Higa 《Computer Technology and Application》 2013年第3期137-143,共7页
A noncontact user interface using image processing for people with neuromuscular diseases is presented in this paper. The user interface is composed of a Web camera and a PC, and allows users to manipulate the PC usin... A noncontact user interface using image processing for people with neuromuscular diseases is presented in this paper. The user interface is composed of a Web camera and a PC, and allows users to manipulate the PC using small movements of single finger. By using image processing techniques with the Web camera, the finger is appropriately detected from the images captured by it. Control boxes for pointing and text input functions are also made. To verify performances of the interface, some tasks are experimentally performed by three able-bodied subjects and a person suffering from spinal muscular atrophy. It was clear from the experimental results that all the subjects could smoothly nerforrn the t,~k~ 展开更多
关键词 Web camera image processing noncontact user interface neuromuscular disorder.
在线阅读 下载PDF
Noncontact Monitoring of Relative Changes in Blood Pressure Using Microwave Radar Sensors
9
作者 Satoshi Suzuki Guanghao Sun +2 位作者 Masaaki Hoshiga Kentaro Kotani Takafumi Asao 《Journal of Biomedical Science and Engineering》 2022年第1期51-65,共15页
This study aims to confirm whether noncontact monitoring of relative changes in blood pressure can be estimated using microwave radar sensors. First, an equation to estimate blood pressure was derived, after which, th... This study aims to confirm whether noncontact monitoring of relative changes in blood pressure can be estimated using microwave radar sensors. First, an equation to estimate blood pressure was derived, after which, the effectiveness of the estimation equation was confirmed using data obtained by a noncontact method while inducing variations in blood pressure. We considered that the Bramwell-Hill equation, which contains some parameters that directly indicate changes in blood pressure, would be an appropriate reference to construct an estimation equation for the noncontact method, because measurements using microwave radar sensors can measure minute scale motion on the skin surface induced by the pulsation of blood vessels. In order to estimate relative changes in blood pressure, we considered a simple equation including the pulse transit time (PTT), amplitude of signals and body dimensions as parameters. To verify the effectiveness of the equation for estimating changes in blood pressure, two experiments were conducted: a cycling task using an ergometer, which induces blood pressure fluctuations because of changes in cardiac output, and a task using the Valsalva maneuver, which induces blood pressure fluctuations because of changes in vascular resistance. The results obtained from the two experiments suggested that the proposed equation using microwave radar sensors can accurately estimate relative changes of blood pressure. In particular, relatively favorable results were obtained for the changes in blood pressure induced by the changes in cardiac volume. Although many issues remain, this method could be expected to contribute to the continuous evaluation of cardiac function while reducing the burden on patients. 展开更多
关键词 Microwave Radar noncontact Monitoring Blood Pressure Relative Change Continuous Monitor
在线阅读 下载PDF
Noncontact photoacoustic lipid imaging by remote sensing on first overtone of the C-H bond
10
作者 Guyue Hu Qiao Ran +5 位作者 Beth Wing Lam So Mingsheng Li Jiawei Shi Xin Dong Jiqiang Kang Kenneth K.Y.Wong 《Advanced Photonics Nexus》 2023年第2期133-140,共8页
Lipid imaging by conventional photoacoustic microscopy subjects to direct contact sensing with relatively low detection bandwidth and sensitivity,which induces superficial imaging depth and low signalto-noise ratio(SN... Lipid imaging by conventional photoacoustic microscopy subjects to direct contact sensing with relatively low detection bandwidth and sensitivity,which induces superficial imaging depth and low signalto-noise ratio(SNR)in practical imaging scenarios.Herein,we present a photoacoustic remote sensing microscopy for lipid distribution mapping in bio-tissue,featuring noncontact implementation,broad detection bandwidth,deep penetration depth,and high SNR.A tailored high-energy pulsed laser source with a spectrum centered at 1750 nm is used as the excitation beam,while a cofocused 1550 nm continuous-wave beam is used as the probe signal.The pump wavelength is selected to overlap the first overtone of the C-H bond in response to the intensive absorption of lipid molecules,which introduces a much-enhanced SNR(55 dB)onto photoacoustic remote sensing(PARS)signals.Meanwhile,the optical sensing scheme of the photoacoustic signals provides broadband detection compared to the acoustic transducer and refrains the bio-samples from direct contact operations by eliminating the ultrasonic coupling medium.Taking merits of the high detection sensitivity,deep penetration depth,broadband detection,and high resolution of the PARS system,high-quality tissue scale lipid imaging is demonstrated in a model organism and brain slice. 展开更多
关键词 photoacoustic microscopy remote sensing lipid imaging near-infrared imaging label-free noncontact
在线阅读 下载PDF
Noncontact 3D gesture recognition enabled VR human-machine interface via electret-nanofiber-based triboelectric sensor
11
作者 Lijun Lu Jing Wu +5 位作者 Yujie Zhang Chang Liu Yun Hu Baojin Chen Yan Zhu Yanchao Mao 《Nano Research》 2025年第11期1189-1198,共10页
Virtual reality(VR)is an emerging communication means and creates extensive opportunities in interacting scenarios such as remote collaboration and metaverse.Human-machine interfaces(HMIs)play important roles in VR as... Virtual reality(VR)is an emerging communication means and creates extensive opportunities in interacting scenarios such as remote collaboration and metaverse.Human-machine interfaces(HMIs)play important roles in VR as they provide interaction platforms between users and virtual environments.However,traditional VR HMIs based on handheld devices or keyboards cannot recognize diverse three-dimensional(3D)gestures,which results in limited freedom of VR interactions.Here,we report a noncontact VR HMI enabled by an electret-nanofiber-based triboelectric sensor(ETS),which is fabricated by the electrospun polylactic acid/thermoplastic polyurethane(PLA/TPU)electret nanofiber film.The nanofiber structure of PLA/TPU electret enhanced the charge retention ability of triboelectric sensor and thus significantly improved its signal strength and stability.Integrated with a deep learning-based multilayer perceptron neural network,the ETS realizes the recognition of 18 different types of 3D gestures with a high average accuracy of 97.3%.An intelligent noncontact VR interactive system based on the ETS is further developed,which is used to manipulate game characters for performing different actions by 3D gestures.Compared with traditional VR HMIs,the proposed VR HMI based on PLA/TPU electret nanofiber film can detect various 3D gestures and offers a superior interaction freedom.This work for the first time introduces the triboelectric 3D gesture recognition method to the VR HMIs,and could make the interaction between human and virtual environments become more efficient and fascinating. 展开更多
关键词 virtual reality human-machine interfaces noncontact three-dimensional(3D)gesture recognition triboelectric sensors electret nanofiber films
原文传递
Flexible piezoelectret film sensor for noncontact mechanical signal capture by multiple transmission media 被引量:1
12
作者 Xingchen Ma Qianqian Hu +7 位作者 Lian Zhou Xinhao Xiang Yi Qin Ke Zhang Pengfei He Ying Dai Wenxin Niu Xiaoqing Zhang 《Nano Research》 SCIE EI CSCD 2024年第8期7643-7657,共15页
Mechanical signal capture without physical contact has emerged as a highly promising research field and attracted tremendous attention due to its prosperous applications in household medical care,lifestyle monitoring ... Mechanical signal capture without physical contact has emerged as a highly promising research field and attracted tremendous attention due to its prosperous applications in household medical care,lifestyle monitoring and remote operation,offering users high level of safety,convenience and comfort.Moreover,noncontact sensing is ideal to maximize the immersive user experience in the human–machine interaction(HMI),eliminating interference to human activities and mechanical fatigue to the sensor,simultaneously.Herein,we report a self-powered flexible sensor integrated with irradiation cross-linked polypropylene(IXPP)piezoelectret film for noncontact sensing,featuring multi-functions to detect mechanical signals transmitted through solid,liquid and gaseous media and would facilitate their versatile practical applications.The folded-structure configuration of the sensor facilitates the improvement of the noncontact sensing sensitivity.For solid media,such as the rectangular wooden stick used in this study,the sensor can detect mechanical stimulus exerted at a distance of 100 cm.A system detection sensitivity up to 57 pC/kPa with a low detection limit of 0.6 kPa is achieved at a noncontact distance of 10 cm.Even when partly or completely immersed in water,the sensor effectively traces movement signals of human bodies underwater,demonstrating great advantages for non-inductive aquatic fitness training monitoring.Furthermore,due to the low acoustic impedance of piezoelectret film,speech recognition through gaseous medium is also achieved.We further introduce application demonstrations of the developed film sensors to monitor exercise postures and physiological signals without direct contact between human body and the sensor,displaying great potential to be incorporated into future smart electronics.This study commendably expands the application scope of piezoelectret materials,which will have profound implications for exploring novel intelligent human–machine interactions. 展开更多
关键词 noncontact sensing piezoelectret multiple transmission media mechanical signal capture
原文传递
Noncontact ultrasound sensing based on Mach-Zehnder homodyne interferometer for photoacoustic imaging
13
作者 龙星 胡毅成 +1 位作者 王一冰 李长辉 《Chinese Optics Letters》 SCIE EI CAS CSCD 2024年第3期101-106,共6页
We present a novel noncontact ultrasound(US)and photoacoustic imaging(PAI)system,overcoming the limitations of traditional coupling media.Using a long coherent length laser,we employ a homodyne free-space Mach-Zehnder... We present a novel noncontact ultrasound(US)and photoacoustic imaging(PAI)system,overcoming the limitations of traditional coupling media.Using a long coherent length laser,we employ a homodyne free-space Mach-Zehnder setup with zero-crossing triggering,achieving a noise equivalent pressure of 703 Pa at 5 MHz and a-6 dB bandwidth of 1 to8.54 MHz.We address the phase uncertainty inherent in the homodyne method.Scanning the noncontact US probe enables photoacoustic computed tomography(PACT).Phantom studies demonstrate imaging performance and system stability,underscoring the potential of our system for noncontact US sensing and PAI. 展开更多
关键词 noncontact ultrasound sensing photoacoustic imaging Mach–Zehnder interferometer
原文传递
基于盲源分离的多人呼吸信号检测方法 被引量:1
14
作者 杨轩 王子颖 +2 位作者 张力 赵恒 洪弘 《雷达学报(中英文)》 北大核心 2025年第1期117-134,共18页
近年来,人们越来越关注多人环境下的呼吸监测,以及如何同时监测多人的健康状态。在多人呼吸检测的算法中,盲源分离算法因其无需先验信息并且对硬件性能依赖性较小而备受研究者关注。然而,在多人呼吸监测场景中,目前的盲源分离算法通常... 近年来,人们越来越关注多人环境下的呼吸监测,以及如何同时监测多人的健康状态。在多人呼吸检测的算法中,盲源分离算法因其无需先验信息并且对硬件性能依赖性较小而备受研究者关注。然而,在多人呼吸监测场景中,目前的盲源分离算法通常将相位信号作为源信号进行分离,该文引入FMCW雷达下距离维信号和相位信号的对比,推导出相位信号作为源信号存在近似误差,并通过仿真验证距离维信号作为源信号时分离效果更好。另外,该文提出了基于非圆复数独立成分分析的多人呼吸信号分离算法,分析了不同呼吸信号参数对分离效果的影响,仿真和实测实验表明,所提出的方法适用于天线个数不小于目标个数时多人呼吸信号的检测,并且在目标角度差为9.46°时,也能够准确分离呼吸信号。 展开更多
关键词 非接触呼吸检测 FMCW雷达 多人呼吸检测 盲源分离 复数独立成分分析
在线阅读 下载PDF
基于希尔伯特–黄变换与频谱加权重构的毫米波雷达心率检测方法
15
作者 崔昊 刘璐瑶 +1 位作者 陈浩 肖文栋 《工程科学学报》 北大核心 2025年第7期1545-1555,共11页
近年来国内外健康问题十分严峻,心率作为评估人体健康状况的重要生命体征指标,对其进行无扰、低负荷检测已成为社会迫切需求.雷达技术的发展使非接触式心率检测成为可能,然而,由于心跳引起的胸腔振动极其微弱,很容易被呼吸谐波、环境杂... 近年来国内外健康问题十分严峻,心率作为评估人体健康状况的重要生命体征指标,对其进行无扰、低负荷检测已成为社会迫切需求.雷达技术的发展使非接触式心率检测成为可能,然而,由于心跳引起的胸腔振动极其微弱,很容易被呼吸谐波、环境杂波噪声淹没,如何克服检测过程中未知环境噪声与呼吸谐波干扰是当前面临的两大严峻挑战.为此,本文提出一种基于希尔伯特–黄变换(Hilbert–Huang transform,HHT)与频谱加权重构的毫米波雷达心率检测方法,实现心率的无扰准确检测.该方法主要由微动目标定位和心跳信号重构估计两种策略组成.其中,微动目标定位策略通过自适应恒虚警率(Constant false alarm rate,CFAR)动态阈值分析,提高动态未知噪声场景下微弱信号目标的定位精度;心跳信号重构估计策略首先通过HHT进行自适应时频局部化分析,提取对应心率区间的本征模态函数,并对其频谱能量进行加权重构,从而进一步抑制心跳信号中的呼吸谐波和噪声干扰,提高心率检测的分辨率.对不同受试个体在不同心率、距离、角度条件下进行实验,结果表明,与现有常用方法相比,本文所提方法可有效抑制呼吸谐波、环境噪声杂波干扰,显著提高人体心率检测精度. 展开更多
关键词 毫米波雷达 非接触式心率检测 自适应恒虚警率 希尔伯特–黄变换 频谱加权重构
在线阅读 下载PDF
弹丸弧形部曲率半径非接触式测量方法研究
16
作者 李家根 王宇航 +1 位作者 张晖 冯进良 《长春理工大学学报(自然科学版)》 2025年第2期78-83,共6页
针对弹丸弧形部曲率半径测量精度低的问题,提出了一种基于光电非接触测量的高精度弧形部曲率半径测量方法。采用卧式测量方案,保证测量轴与弹丸回转轴方向一致,利用激光位移传感器沿轴向对弹丸弧形部进行扫描,将弹丸弧形部的轮廓信息与... 针对弹丸弧形部曲率半径测量精度低的问题,提出了一种基于光电非接触测量的高精度弧形部曲率半径测量方法。采用卧式测量方案,保证测量轴与弹丸回转轴方向一致,利用激光位移传感器沿轴向对弹丸弧形部进行扫描,将弹丸弧形部的轮廓信息与轴向位移相关联,然后经最小二乘拟合,得到其轮廓曲线,继而得到弧形部曲率半径。对测量系统进行了精度分析,以此为依据设计了系统结构。实际测量结果表明,该方法可有效对实际弹丸弧形部曲率半径进行测量,ΔR≤0.1 mm,为弹丸弧形部曲率半径测量提供了一种全新技术手段。 展开更多
关键词 曲率半径 光电非接触测量 扫描 最小二乘拟合
在线阅读 下载PDF
On-Surface Stereochemical Characterization of a Highly Curved Chiral Nanographene by Noncontact Atomic Force Microscopy and Scanning Tunneling Microscopy 被引量:2
17
作者 Qigang Zhong Viktor Barat +8 位作者 Daniel Csokas Kaifeng Niu Marcin Gorecki Animesh Ghosh Jonas Bjork Daniel Ebeling Lifeng Chi Andre Schirmeisen Mihaiela C.Stuparu 《CCS Chemistry》 CSCD 2023年第12期2888-2896,共9页
A highly distorted chiral nanographene structure composed of triple corannulene-fused[5]helicenes is prepared with the help of the Heck reaction and oxidative photocyclization with an overall isolated yield of 28%.The... A highly distorted chiral nanographene structure composed of triple corannulene-fused[5]helicenes is prepared with the help of the Heck reaction and oxidative photocyclization with an overall isolated yield of 28%.The complex three-dimensional(3D)structure of the bowl-helix hybrid nanostructure is studied by a combination of noncontact atomic force microscopy(AFM)and scanning tunneling microscopy(STM)on the Cu(111)surface,density functional theory calculations,AFM/STM simulations,and high-performance liquid chromatography-electronic circular dichroism analysis.This examination reveals a molecular structure in which the three bowl-shaped corannulene bladesd position themselves in a C3-symmetric fashion around a highly twisted triphenylene core.The molecule appears to be shaped like a propeller in which the concave side of the bowls face away from the connected[5]helicene motif.The chirality of the nanostructure is confirmed by the direct visualization of both MMM and PPP enantiomers at the single-molecule level by scanning probe microscopies.These results underline that submolecular resolution imaging by AFM/STM is a powerful real-space tool for the stereochemical characterization of 3D curved chiral nanographene structures. 展开更多
关键词 chirality at surfaces noncontact atomic force microscopy scanning tunnelling microscopy submolecular resolution imaging single-bond resolution curved nanographenes multiple helicenes chiral nanostructures bowl-helix hybrids scanning probe microscopy
在线阅读 下载PDF
Two-sided ultrasonic surface rolling process of aeroengine blades based on on-machine noncontact measurement 被引量:1
18
作者 Shulei YAO Xian CAO +4 位作者 Shuang LIU Congyang GONG Kaiming ZHANG Chengcheng ZHANG Xiancheng ZHANG 《Frontiers of Mechanical Engineering》 SCIE CSCD 2020年第2期240-255,共16页
As crucial parts of an aeroengine,blades are vulnerable to damage from long-term operation in harsh environments.The ultrasonic surface rolling process(USRP)is a novel surface treatment technique that can highly impro... As crucial parts of an aeroengine,blades are vulnerable to damage from long-term operation in harsh environments.The ultrasonic surface rolling process(USRP)is a novel surface treatment technique that can highly improve the mechanical behavior of blades.During secondary machining,the nominal blade model cannot be used for secondary machining path generation due to the deviation between the actual and nominal blades.The clamping error of the blade also affects the precision of secondary machining.This study presents a two-sided USRP(TS-USRP)machining for aeroengine blades on the basis of on-machine noncontact measurement.First,a TS-USRP machining system for blade is developed.Second,a 3D scanning system is used to obtain the point cloud of the blade,and a series of point cloud processing steps is performed.A local point cloud automatic extraction algorithm is introduced to extract the point cloud of the strengthened region of the blade.Then,the tool path is designed on the basis of the extracted point cloud.Finally,an experiment is conducted on an actual blade,with results showing that the proposed method is effective and efficient. 展开更多
关键词 aeroengine blades on-machine noncontact measurement point cloud processing path planning surface strengthening
原文传递
High-performance optical noncontact controlling system based on broadband PtTex/Si heterojunction photodetectors for human-machine interaction 被引量:1
19
作者 Zhexin Li Wenhao Ran +3 位作者 Yongxu Yan Linlin Li Zheng Lou Guozhen Shen 《InfoMat》 SCIE CAS 2022年第1期142-154,共13页
Noncontact interaction systems have attracted considerable research attention in recent years because of convenient operation,sterility,and injury prevention.However,the insufficient sensing distance and weak robustne... Noncontact interaction systems have attracted considerable research attention in recent years because of convenient operation,sterility,and injury prevention.However,the insufficient sensing distance and weak robustness of noncontact interaction systems for complex environments limit their practical applications.Here,we designed an integrated optical noncontact controlling system(ONCS)based on PtTe_(x)/Si optoelectronic heterojunction array.Broadband sensitive photoresponse is realized at zero bias voltage,with excellent detectivity and responsivity,boosting the noncontact sensing distance to at least 150 mm.Consequently,the system can perform noncontact detection,encoding,and control by recognizing shadow-induced spatiotemporal sequence changes in heterojunction array photocurrents.As a proof of concept,different interactive functions have been demonstrated with good accuracy and robustness by encoding finger movement above the ONCS.This study provides a new perspective for constructing high-performance noncontact interaction systems. 展开更多
关键词 human-machine interaction optical noncontact controlling PtTex/Si heterostructure self-powered photodetector
原文传递
预制拼装桥梁UHPC接缝受拉和受弯试验研究
20
作者 詹秋迎 《山西交通科技》 2025年第5期128-132,共5页
为验证钢筋非接触搭接布置形式UHPC湿接缝在受拉和受弯方面的性能,选取了UHPC接缝长度、纵筋埋置深度、纵筋搭接长度、纵筋间距、纵筋直径、有无横筋等6个试验参数,开展了UHPC接缝试件受拉和受弯试验,分析了试件的荷载位移曲线、破坏模... 为验证钢筋非接触搭接布置形式UHPC湿接缝在受拉和受弯方面的性能,选取了UHPC接缝长度、纵筋埋置深度、纵筋搭接长度、纵筋间距、纵筋直径、有无横筋等6个试验参数,开展了UHPC接缝试件受拉和受弯试验,分析了试件的荷载位移曲线、破坏模式和受力性能。试验结果表明:UHPC接缝纵筋埋置深度和搭接长度增加均有利于UHPC接缝内部承载能力的提高;纵筋间距显著影响UHPC接缝极限荷载,极限荷载随着纵筋间距增加先减小后增加;横向钢筋对接缝内部延性的提升起到较大作用,但对极限荷载的提高效果有限;UHPC接缝钢筋受弯情况下需要的锚固长度低于受拉时的锚固长度。 展开更多
关键词 钢筋非接触搭接 UHPC接缝 破坏模式 受拉和受弯试验 参数分析
在线阅读 下载PDF
上一页 1 2 15 下一页 到第
使用帮助 返回顶部