期刊文献+
共找到11,241篇文章
< 1 2 250 >
每页显示 20 50 100
Learning by Comparing:Effects of Cues Focusing on Chinese-Speaking Learners’Acquisition of English Articles
1
作者 Mei Yang Qiying Guo Xiaomeng Yan 《Chinese Journal of Applied Linguistics》 2026年第1期57-75,160,共20页
This study examines whether and how cues focusing enhances Chinese-speaking English learners’engagement in comparison,thereby facilitating their acquisition of English articles within xu-based comparative continuatio... This study examines whether and how cues focusing enhances Chinese-speaking English learners’engagement in comparison,thereby facilitating their acquisition of English articles within xu-based comparative continuation writing tasks.Fifty English majors from a Chinese university were randomly assigned to three groups and each group was required to complete a comparative continuation task with one of three conditions:paired cues(cues presented in pairs),randomized cues(cues presented in random order),or implicit cues(no explicit cues provided).All participants undertook pretests,posttests,and delayed tests on English article knowledge,and ten of them volunteered to take follow-up interviews.The results indicate that:1)paired cues were more effective than randomized or implicit cues in promoting the acquisition of English articles;and 2)learners in the paired cues condition produced more target-like article usage in their continuation writings compared to those in the other two conditions.The effectiveness of paired cues is attributed to an enhanced contrast effect,which prompts learners to identify similarities and differences between cues within each pair,relates cue explanations and examples with actual article usage in the reading text,and reflects upon and compares their own article productions against those in the provided reading text.The study concludes that the process of learning through continuation is fundamentally supported by learners’capacity for comparison,reinforcing its role as a core element of xu-competence. 展开更多
关键词 comparison cues focusing acquisition of English articles xu-argument
在线阅读 下载PDF
Case studies of ion focusing in the downstream region of a modeled low Earth orbit spacecraft
2
作者 Nizam Ahmad Hideyuki Usui +4 位作者 Yohei Miyake Slamet Supriadi Hanif Fakhrurroja Hilman Syaeful Alam Harry Bangkit 《Earth and Planetary Physics》 2026年第1期136-143,共8页
The effect of plasma and charged particle interaction with spacecraft in a low Earth orbit(LEO)environment leads to ion focusing and the formation of an ion void in the downstream region as a result of charging.Simula... The effect of plasma and charged particle interaction with spacecraft in a low Earth orbit(LEO)environment leads to ion focusing and the formation of an ion void in the downstream region as a result of charging.Simulations and investigations using a fixed potential imposed on the spacecraft showed the nonsignificance of geophysical parameter changes to ion focusing.Variation of the temperature ratio(T_(r))contributed only to local ion focusing and manifested as two-ion streamers dispersed at the upper and lower edges of the spacecraft-the outermost layers of the satellite structure at the top and bottom,respectively.A simulation involving changing the ambient plasma density(N_(p))also showed the formation of local ion focusing,in which ions were more concentrated as the density increased.Furthermore,auroral electron density(N_(ae))variation had no clear impact on ion focusing,as indicated by static two-ion structures in the wake field.However,variation of the object potential(ϕ)strongly affected ion focusing formation,leading to distortion of the initial ion void region behind the spacecraft.The formation of ion focusing in this study was subject to the electric field produced by the object potential and the ambipolar electric field resulting from plasma expansion in the downstream region. 展开更多
关键词 ion focusing spacecraft potential low Earth orbit environment
在线阅读 下载PDF
Three-dimensional spatial multi-point uniform light focusing through scattering media based on feedback wavefront shaping
3
作者 Fan Yang Yang Zhao +2 位作者 Chengchao Xiang Qi Feng Yingchun Ding 《Chinese Physics B》 SCIE EI CAS CSCD 2021年第4期264-270,共7页
We use feedback wavefront shaping technology to realize the multi-point uniform light focusing in three-dimensional(3D) space through scattering media only by loading the optimal mask once.General 3D spatial focusing ... We use feedback wavefront shaping technology to realize the multi-point uniform light focusing in three-dimensional(3D) space through scattering media only by loading the optimal mask once.General 3D spatial focusing needs to load the optimal mask multiple times to realize the spatial movement of the focal point and the uniformity of multi-point focusing cannot be guaranteed.First,we investigate the effects of speckle axial correlation and different axial distances on 3D spatial multi-point uniform focusing and propose possible solutions.Then we use our developed non-dominated sorting genetic algorithm suitable for 3D spatial focusing(S-NSGA) to verify the experiment of multi-point focusing in 3D space.This research is expected to have potential applications in the fields of optical manipulation and optogenetics. 展开更多
关键词 wavefront shaping speckle correlation 3D spatial focusing multi-point focusing
原文传递
FOCUS 夫妻干预对不孕症患者夫妇心理状况及生育生活质量的影响
4
作者 吴姗 马瑞条 杜苓燕 《临床心身疾病杂志》 2026年第1期60-64,共5页
目的探讨FOCUS夫妻干预对不孕症患者夫妇心理状况及生育生活质量的影响。方法将96对不孕症患者及其配偶作为研究对象,随机分成研究组和对照组,各48对。对照组受试者给予常规干预措施,研究组受试者在对照组基础上给予FOCUS夫妻干预。干... 目的探讨FOCUS夫妻干预对不孕症患者夫妇心理状况及生育生活质量的影响。方法将96对不孕症患者及其配偶作为研究对象,随机分成研究组和对照组,各48对。对照组受试者给予常规干预措施,研究组受试者在对照组基础上给予FOCUS夫妻干预。干预前后,比较两组受试者心理弹性[心理弹性量表(CD-RISC)评分]、生育压力[生育压力量表(FPI)评分]、总体幸福感[总体幸福感量表(GWBS)评分]、夫妻支持应对水平[夫妻支持应对量表(DCI)评分]及生育生活质量[生育生活质量问卷评分]。结果干预后,两组患者及其配偶CD-RISC、GWBS、DCI评分较干预前升高,且研究组高于对照组(P<0.05或0.01);两组患者及其配偶FPI评分较干预前降低,且研究组低于对照组(P<0.01);两组受试者生育生活质量总优良率较干预前提高,且研究组高于对照组(P<0.05或0.01)。结论FOCUS夫妻干预应用于不孕症患者夫妇临床效果良好,可改善夫妻双方的心理状况和生育生活质量。 展开更多
关键词 不孕症 focus夫妻干预 心理状况 生育生活质量
暂未订购
Sub-diffraction-limited focusing laser pulses at ultrahigh intensity via near-critical-density hollow plasma fibers
5
作者 Tianqi Xu Zhuo Pan +12 位作者 Ying Gao Yulan Liang Shirui Xu Qingfan Wu Tan Song Yujia Zhang Haoran Chen Qihang Han Chenghao Hua Ziyang Peng Ke Chen Xuan Liu Wenjun Ma 《Advanced Photonics Nexus》 2025年第6期64-71,共8页
Ultra-intense electromagnetic fields exceeding 10^(23)W∕cm^(2)are enabling breakthroughs in compact laser-driven particle accelerators and revealing new quantum electrodynamics(QED)phenomena.However,conventional lase... Ultra-intense electromagnetic fields exceeding 10^(23)W∕cm^(2)are enabling breakthroughs in compact laser-driven particle accelerators and revealing new quantum electrodynamics(QED)phenomena.However,conventional laser-focusing methods face considerable engineering challenges and require substantial costs.Focusing schemes utilizing plasma optics can produce sub-micrometer focus spots beyond the diffraction limit and substantially enhance the peak intensity;however,owing to significant energy dissipation,they may fail to simultaneously increase the laser fluence.To address these challenges,we propose a focusing scheme employing a near-critical-density hollow plasma fiber(HPF)that utilizes graded refractive index dynamics to boost both laser peak intensity and fluence at the same time.Three-dimensional particle-in-cell simulations demonstrate the HPF’s capability to focus a 4.5-μm-diameter Gaussian beam to a sub-diffraction-limited 0.6-μm-diameter spot.The peak intensity and laser fluence can be enhanced by factors of 22 and 10,respectively,marking a substantial improvement over existing plasma-based focusing schemes.Furthermore,the proposed scheme exhibits wide-range parameter adaptation and high robustness,making it suitable for direct implementation in PW-class ultra-intense laser experiments. 展开更多
关键词 plasma optics laser focusing intensity enhancement
在线阅读 下载PDF
Energy focusing of flexural waves via algorithmically optimized coding metasurface lenses
6
作者 Zi-Rui Wang Di-Chao Chen +1 位作者 Rui Hong Da-Jian Wu 《Chinese Physics B》 2025年第9期277-282,共6页
Efficient elastic wave focusing is crucial in materials and physical engineering.Elastic coding metasurfaces,which are innovative planar artificial structures,show great potential for use in the field of wave focusing... Efficient elastic wave focusing is crucial in materials and physical engineering.Elastic coding metasurfaces,which are innovative planar artificial structures,show great potential for use in the field of wave focusing.However,elastic coding lenses(ECLs)still suffer from low focusing performance,thickness comparable to wavelength,and frequency sensitivity.Here,we consider both the structural and material properties of the coding unit,thus realizing further compression of the thickness of the ECL.We chose the simplest ECL,which consists of only two encoding units.The coding unit 0 is a straight structure constructed using a carbon fiber reinforced composite material,and the coding unit 1 is a zigzag structure constructed using an aluminum material,and the thickness of the ECL constructed using them is only 1/8 of the wavelength.Based on the theoretical design,the arrangement of coding units is further optimized using genetic algorithms,which significantly improves the focusing performance of the lens at different focus and frequencies.This study provides a more effective way to control vibration and noise in advanced structures. 展开更多
关键词 coding metasurface elastic wave focusing genetic algorithm
原文传递
Dynamically Tunable THz Focusing via Mechanically Rotatable Cascaded Metasurfaces With Polarization Multiplexing
7
作者 Hui Li Wenhui Xu +5 位作者 Hang Xu Jie Li Chunyu Song Qun Ren Yang Ren Jianquan Yao 《SmartSys》 2025年第3期1-9,共9页
Dynamically tunable terahertz(THz)beam focusing plays a critical role in emerging applications including reconfigurable imaging,localized spectral analysis,and micro-machining.Conventional methods,however,frequently e... Dynamically tunable terahertz(THz)beam focusing plays a critical role in emerging applications including reconfigurable imaging,localized spectral analysis,and micro-machining.Conventional methods,however,frequently employ complex wavefront modulators and external control algorithms,resulting in increased system footprint and limited tuning efficiency.In this work,we present an all-silicon mechanically rotatable cascaded metasurface capable of dynamic THz beam focusing.By independently adjusting the relative rotation angles between the two metasurface layers,real-time repositioning of the focal spot is achieved for orthogonal circular polarization channels.The proposed design facilitates polarization-division multiplexing without requiring external algorithms or active materials while preserving high focusing efficiency and beam quality across a predefined focal plane.Numerical simulations reveal a quasi-linear shift of the focal position with the rotation angle,with stable focusing efficiency and full-width at half-maximum observed in both polarization channels.This strategy offers an efficient and reliable approach to dynamic wavefront control for compact,reconfigurable THz imaging,sensing,and communication systems. 展开更多
关键词 cascaded metasurface dynamic beam focusing polarization-division multiplexing TERAHERTZ wavefront control
在线阅读 下载PDF
A tunable acoustic metasurface via one-dimensional mechanical adjustment for real-time focusing
8
作者 Jie Hu Mengqi Jiang +1 位作者 Rui Zang Yuhang Qian 《Chinese Physics B》 2025年第10期399-404,共6页
Adjustable or programmable metamaterials offer versatile functions,while the complex multi-dimensional regulation increases workload,and hinders their applications in practical scenarios.To address these challenges,we... Adjustable or programmable metamaterials offer versatile functions,while the complex multi-dimensional regulation increases workload,and hinders their applications in practical scenarios.To address these challenges,we present a mechanically programmable acoustic metamaterial for real-time focal tuning via one-dimensional phase-gradient modulation in this paper.The device integrates a phase gradient structure with concave cavity channels and an x-shaped telescopic mechanical framework,enabling dynamic adjustment of inter-unit spacing(1 mm-3 mm)through a microcontroller-driven motor.By modulating the spacing between adjacent channels,the phase gradient is precisely controlled,allowing continuous focal shift from 50 mm to 300 mm along the x-axis at 7500 Hz.Broadband focusing is also discussed in the range6800 Hz-8100 Hz,with transmission coefficients exceeding 0.5,ensuring high efficiency and robust performance.Experimental results align closely with simulations,validating the design's effectiveness and adaptability.Unlike conventional programmable metamaterials requiring multi-dimensional parameter optimization,this approach simplifies real-time control through single-axis mechanical adjustment,significantly reducing operational complexity.Due to the advantages of broadband focusing,simple control mode,real-time monitoring,and so on,the device may have extensive applications in the fields of acoustic imaging,nondestructive testing,ultrasound medical treatment,etc. 展开更多
关键词 phase gradient structure one-dimensional mechanical adjustment adjustable focusing
原文传递
Plume focusing characteristics and optimal design of Hall thruster with large height-radius ratio
9
作者 Haotian FAN Yewei ZHANG +1 位作者 Huixin YANG Yongjie DING 《Chinese Journal of Aeronautics》 2025年第11期18-27,共10页
Hall thrusters with large height-radius ratio,owing to their unique advantages in compactness,lightweight,and high performance,have progressively emerged as a preferred choice for diverse space propulsion applications... Hall thrusters with large height-radius ratio,owing to their unique advantages in compactness,lightweight,and high performance,have progressively emerged as a preferred choice for diverse space propulsion applications in the future.However,the amplification of the annular effect in structures with a large height-radius ratio poses a practical problem of plume over-focusing,which seriously restricts the further improvement of Hall thruster performance and the extension of its life.In this study,the formation mechanism of over-focused plume is deeply investigated,and it is ascertained that an intensified radial electric field directed towards the inner wall within the channel serves as a key contributing factor.This phenomenon is fundamentally attributed to structural characteristics of large height-radius ratio that induce pronounced inward inclination of field lines within strong magnetic field zone.Based on this,the design concept of focused magnetic field is proposed,wherein straight magnetic field lines are established within the strong magnetic field zone to generate a quasi-axial accelerating electric field.Simultaneously,the symmetrical magnetic field inside the channel ensures ionization concentration near the channel center,thereby achieving optimal matching between the ionization zone and accelerating field.Experimental results demonstrate that employing a focused magnetic field significantly reduces the divergence half-angle of the plume and yields an excellently barrel-shaped focusing plume morphology in HEP-1350PM.Consequently,the total efficiency of the thruster surpasses 60%,while erosion belt on the inner wall is shortened by nearly 50%.These advancements effectively enhance thruster performance and prolong its operational lifespan.This study can not only resolve practical problems associated with plume over-focusing,but also provide a fundamental guiding principle for magnetic field design of Hall thrusters. 展开更多
关键词 Electric propulsion Hall thruster Large height-radius ratio Magnetic field design Plume focusing characteristics
原文传递
Experimental analysis of internal flow and spray characteristics of flow focusing/blurring nozzle
10
作者 Jin Zhao Zhi Ning +1 位作者 Ming Lv Xu He 《Chinese Journal of Chemical Engineering》 2025年第7期111-124,共14页
This study utilizes a visualization nozzle and spray experimental platform to experimentally investigate the flow focusing/blurring nozzle.It is found that the working mode of the nozzle transitions from flow focusing... This study utilizes a visualization nozzle and spray experimental platform to experimentally investigate the flow focusing/blurring nozzle.It is found that the working mode of the nozzle transitions from flow focusing to flow transition and eventually to flow blurring as the gas flow rate increases or the tube hole distance decreases.Conversely,an increase in liquid flow rate only facilitates the transition from flow focusing to flow transition.Changes in the gas/liquid flow rate or tube hole distance influence the gas shear effect and the gas inertial impact effect inside the nozzle,which in turn alters the working mode.An increase in gas flow rate results in a shift of the droplet size distribution towards smaller particle sizes in the flow blurring mode,whereas an increase in liquid flow rate produces the opposite effect.Notably,the impact of the gas flow rate on these changes is more pronounced than that of the liquid flow rate. 展开更多
关键词 Flow focusing/blurring nozzle Working mode Gaseliquid flow Multiphase flow Particle size distribution
在线阅读 下载PDF
Therapeutic effects of low-intensity transcranial focused ultrasound stimulation on ischemic stroke in rats:An in vivo evaluation using electrical impedance tomography
11
作者 Jiecheng Guo Sixuan He +4 位作者 Li Yan Lei Wang Xuetao Shi Huijing Hu Le Li 《Neural Regeneration Research》 2026年第3期1183-1190,共8页
Although previous studies have demonstrated that transcranial focused ultrasound stimulation protects the ischemic brain,clear criteria for the stimulation time window and intensity are lacking.Electrical impedance to... Although previous studies have demonstrated that transcranial focused ultrasound stimulation protects the ischemic brain,clear criteria for the stimulation time window and intensity are lacking.Electrical impedance tomography enables real-time monitoring of changes in cerebral blood perfusion within the ischemic brain,but investigating the feasibility of using this method to assess post-stroke rehabilitation in vivo remains critical.In this study,ischemic stroke was induced in rats through middle cerebral artery occlusion surgery.Transcranial focused ultrasound stimulation was used to treat the rat model of ischemia,and electrical impedance tomography was used to measure impedance during both the acute stage of ischemia and the rehabilitation stage following the stimulation.Electrical impedance tomography results indicated that cerebral impedance increased after the onset of ischemia and decreased following transcranial focused ultrasound stimulation.Furthermore,the stimulation promoted motor function recovery,reduced cerebral infarction volume in the rat model of ischemic stroke,and induced the expression of brain-derived neurotrophic factor in the ischemic brain.Our results also revealed a significant correlation between the impedance of the ischemic brain post-intervention and improvements in behavioral scores and infarct volume.This study shows that daily administration of transcranial focused ultrasound stimulation for 20 minutes to the ischemic hemisphere 24 hours after cerebral ischemia enhanced motor recovery in a rat model of ischemia.Additionally,our findings indicate that electrical impedance tomography can serve as a valuable tool for quantitatively evaluating rehabilitation after ischemic stroke in vivo.These findings suggest the feasibility of using impedance data collected via electrical impedance tomography to clinically assess the effects of rehabilitatory interventions for patients with ischemic stroke. 展开更多
关键词 animal model brain stimulation electrical impedance tomography evaluation impedance noninvasive treatment real-time monitoring REHABILITATION STROKE transcranial focused ultrasound stimulation
暂未订购
DETONATION INITIATION INDUCED BY FLAME IMPLOSION AND SHOCK WAVE FOCUSING 被引量:2
12
作者 秦亚欣 于军力 高歌 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2011年第1期57-65,共9页
Computational simulations on structurally different detonation generator are carried out to study the phenomena,the mechanism and the gas dynamics characteristics of flame implosion and shock wave focusing.Two-dimensi... Computational simulations on structurally different detonation generator are carried out to study the phenomena,the mechanism and the gas dynamics characteristics of flame implosion and shock wave focusing.Two-dimensional axisymmetric and unsteady Navier-Stokes equations are numerically solved and detailed chemical reaction kinetics of hydrogen/air mixture is used.The simulation results show that the laminar flame generated by low energy spark in the jet flame burner is accelerated under the narrow channel,the jet flame impinging on the axis strengthens shock wave and the shock wave enhances flame acceleration.Under the function of multiple shock waves and flame,a number of hot spots appear between the wave and the surface.The spots enlarge rapidly,thus forming an over-drive detonation with high pressure,and then declining to stable detonation.Through calculation and analysis,the length of detonation initiation and stable detonation are obtained,thus providing the useful information for further experimental investigations. 展开更多
关键词 DETONATION shock wave focusing flame implosion deflagration-to-detonation
在线阅读 下载PDF
NUMERICAL INVESTIGATION OF TOROIDAL SHOCK WAVES FOCUSING USING DISCONTINUOUS GALERKIN FINITE ELEMENT METHOD 被引量:2
13
作者 陈二云 赵改平 +1 位作者 卓文涛 杨爱玲 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2012年第1期9-15,共7页
A numerical simulation of the toroidal shock wave focusing in a co-axial cylindrical shock tube is inves- tigated by using discontinuous Galerkin (DG) finite element method to solve the axisymmetric Euler equations.... A numerical simulation of the toroidal shock wave focusing in a co-axial cylindrical shock tube is inves- tigated by using discontinuous Galerkin (DG) finite element method to solve the axisymmetric Euler equations. For validating the numerical method, the shock-tube problem with exact solution is computed, and the computed results agree well with the exact cases. Then, several cases with higher incident Mach numbers varying from 2.0 to 5.0 are simulated. Simulation results show that complicated flow-field structures of toroidal shock wave diffraction, reflection, and focusing in a co-axial cylindrical shock tube can be obtained at different incident Mach numbers and the numerical solutions appear steep gradients near the focusing point, which illustrates the DG method has higher accuracy and better resolution near the discontinuous point. Moreover, the focusing peak pres- sure with different grid scales is compared. 展开更多
关键词 shock wave focusing spherical double Math reflection discontinuous galerkin finite element method
在线阅读 下载PDF
Physical Investigation of Directional Wave Focusing and Breaking Waves in Wave Basin 被引量:14
14
作者 柳淑学 Keyyong HONG 《China Ocean Engineering》 SCIE EI 2005年第1期21-35,共15页
An experimental scheme for the generation of directional focusing waves in a wave basin is established in this paper. The effects of the directional range, frequency width and center frequency on the wave focusing are... An experimental scheme for the generation of directional focusing waves in a wave basin is established in this paper. The effects of the directional range, frequency width and center frequency on the wave focusing are studied. The distribution of maximum amplitude and the evolution of time series and spectra during wave packet propagation and the variation of water surface parameters are extensively investigated. The results reveal that the characteristics of focusing waves are significantly influenced by wave directionality and that the breaking criteria for directional waves are distinctly different from those for unidirectional waves. 展开更多
关键词 wave focusing breaking waves directional spreading
在线阅读 下载PDF
A method of laser focusing control in microlaser-induced breakdown spectroscopy 被引量:6
15
作者 Wei WANG Lanxiang SUN +3 位作者 Peng ZHANG Liming ZHENG Lifeng QI Wei DONG 《Plasma Science and Technology》 SCIE EI CAS CSCD 2019年第3期31-39,共9页
This paper presents a method for the automatic adjustment of the laser defocusing amount in micro-laser-induced breakdown spectroscopy. A microscopic optical imaging system consisting of a CCD camera and a 20× ob... This paper presents a method for the automatic adjustment of the laser defocusing amount in micro-laser-induced breakdown spectroscopy. A microscopic optical imaging system consisting of a CCD camera and a 20× objective lens was adopted to realize the method. The real-time auto-focusing of the system was achieved by detecting the effective pixels of the light spot generated by the laser pointer. The focusing accuracy of the method could achieve 3 μm. The element concentrations of Mn and Ni in low-alloy steels were analyzed at a crater diameter of about 35 μm using the presented method. After using the presented method, the determination coefficients of Mn and Ni both exceeded 0.997, with the root-mean-square errors being 0.0133 and 0.0395, respectively. Scanning analysis was performed on the inclined plane and the curved surface by means of focusing control and non-focusing control. Ten characteristic spectral lines of Fe were selected as the analysis lines. With the focusing control, the average relative standard deviations obtained on the inclined plane and curved surface were both less than 5%, and much less than the values without focusing control, 14.6% and 40.39%. 展开更多
关键词 LIBS MICROANALYSIS ablation CRATER focusing control
在线阅读 下载PDF
Efficient Focusing Models for Generation of Freak Waves 被引量:11
16
作者 赵西增 孙昭晨 梁书秀 《China Ocean Engineering》 SCIE EI 2009年第3期429-440,共12页
Four focusing models for generation of freak waves are presented. An extreme wave focusing model is presented on the basis of the enhanced High-Order Spectral (HOS) method and the importance of the nonlinear wave-wa... Four focusing models for generation of freak waves are presented. An extreme wave focusing model is presented on the basis of the enhanced High-Order Spectral (HOS) method and the importance of the nonlinear wave-wave interaction is evaluated by comparison of the calculated results with experimental and theoretical data. Based on the modification of the Longuet-Higgins model, four wave models for generation of freak waves (a. extreme wave model + random wave model; b. extreme wave model + regular wave model; e. phase interval modulation wave focusing model; d. number modulation wave focusing model with the same phase) are proposed. By use of different energy distribution techniques in the four models, freak wave events are obtained with different Hmax/Hs in finite space and time. 展开更多
关键词 High-Order-Spectral HOS freak wave wave focusing Longuet-Higgins model phase modulation
在线阅读 下载PDF
Numerical Study of Two-Dimensional Focusing Waves 被引量:5
17
作者 李金宣 柳淑学 洪起庸 《China Ocean Engineering》 SCIE EI 2008年第2期253-266,共14页
Two-dimensional focusing waves are generated and investigated by numerical method. The numerical model is developed by introducing the wave maker boundary on the high-order spectral (HOS) method proposed by Dommermu... Two-dimensional focusing waves are generated and investigated by numerical method. The numerical model is developed by introducing the wave maker boundary on the high-order spectral (HOS) method proposed by Dommermuth and Yue in 1987 and verified by theoretical and experimental data. Some cases of focusing waves considering different parameters such as assumed focusing amplitudes, frequency bandwidth, central frequency and frequency spectrum are generated. Characteristics of the focusing wave including surface elevations, the maximum crest, shift of focusing points and frequency spectra are discussed. The results show that the focusing wave characteristics are strongly affected by focusing amplitudes, frequency bandwidth, central frequency and frequency spectrum. 展开更多
关键词 high-order spectral method focusing wave monerical method
在线阅读 下载PDF
Numerical simulation of flow focusing pattern and morphological changes in two-phase flow inside nozzle 被引量:2
18
作者 Jin Zhao Zhi Ning +1 位作者 Ming Lü Geng Wang 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2019年第1期63-71,共9页
The flow focusing nozzle is a new type of nozzle that performs effective atomization of the discrete phase by means of high-speed motion of the continuous phase.The flow pattern and its morphological changes have a si... The flow focusing nozzle is a new type of nozzle that performs effective atomization of the discrete phase by means of high-speed motion of the continuous phase.The flow pattern and its morphological changes have a significant effect on the atomization, but the influence of different parameters on the morphological change of the flow pattern remains unclear.The flow focusing pattern and morphological changes in the two-phase flow inside the nozzle were simulated numerically, based on the volume of fluid method.The results demonstrate that the ratio of the nozzle-to-capillary distance and capillary diameter, the gas–liquid velocity ratio, and capillary diameter have significant effects on the flow pattern.When the ratio of the nozzle-to-capillary distance H and capillary diameter D increases, or the capillary diameter D increases, the flow pattern tends to transform into a laminar form; however, when the gas–liquid velocity ratio V increases, the flow pattern tends to transform into a turbulence form.Furthermore, we define the cone-shaped expansion rate, cone-shaped focusing rate,and cone angle in order to study the morphological changes in the cone shape inside the nozzle.The results indicate that the morphological change of the cone shape and flow pattern transformation is interrelated.When the cone shape tends to be unstable, the flow pattern changes towards flow blurring, whereas, a stable cone indicates that the flow tends to exhibit a droplet pattern. 展开更多
关键词 Flow focusing PATTERN TRANSFORMATION MORPHOLOGICAL changes Numerical simulation
在线阅读 下载PDF
Polycapillary X-ray lens for the secondary focusing Beijing synchrotron radiation source 被引量:3
19
作者 李玉德 林晓燕 +4 位作者 刘世岗 何金龙 郭非 孙天希 刘鹏 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第4期248-252,共5页
According to intensity distribution of the synchrotron radiation source focused by a toroidal mirror at the Beijing synchrotron radiation biological macromolecule station, theoretical modeling of the Beijing synchrotr... According to intensity distribution of the synchrotron radiation source focused by a toroidal mirror at the Beijing synchrotron radiation biological macromolecule station, theoretical modeling of the Beijing synchrotron radiation source is developed for capillary optics. Using this theoretical modeling, the influences of the configuration curve of the polycapillary X-ray lens on transmission efficiency and working distance are analyzed. The experimental results of the transmission efficiency and working distance at the biological macromolecule station are in good agreement with the theoretical results. 展开更多
关键词 Beijing synchrotron radiation facility polycapillary X-ray lens secondary focusing
原文传递
Small-Scale Self-Focusing of Intense Laser Beams In the Presence of Vector Effect 被引量:8
20
作者 WEN Shuang-Chun FAN Dian-yuan 《Chinese Physics Letters》 SCIE CAS CSCD 2000年第10期731-733,共3页
We extend Bespalov-Talanov (B-T) theory on small-scale self-focusing (SSSF) to include vector effect of a very narrow intense laser beam with application of the vector self-focusing model. The gain spectrum for pertur... We extend Bespalov-Talanov (B-T) theory on small-scale self-focusing (SSSF) to include vector effect of a very narrow intense laser beam with application of the vector self-focusing model. The gain spectrum for perturbations is obtained by using the standard linear instability analysis. It is shown that the influence on SSSF of vector effect is closely related to the beam width. For a very narrow beam, the role played by vector effect becomes significant, it reduces the fastest growing frequency and the maximum growth rate, and shortens the frequency range for perturbation growing, and thus deviates the gain spectrum from that of B-T theory. 展开更多
关键词 focus SMALL PRESENCE
原文传递
上一页 1 2 250 下一页 到第
使用帮助 返回顶部