This paper presents the basic concepts and principles,data structure and high efficient spatial index for multi_resolution image database.The database is characterized by arrangement of multi_resource image data and s...This paper presents the basic concepts and principles,data structure and high efficient spatial index for multi_resolution image database.The database is characterized by arrangement of multi_resource image data and seamless mosaic,distribution_based storage and management,integration with other spatial database software such as GeoStar and GeoGrid developed by Wuhan Technical University of Surveying and Mapping.展开更多
Considering that there is no single full reference image quality assessment method that could give the best performance in all situations, some multi-method fusion metrics were proposed. Machine learning techniques ar...Considering that there is no single full reference image quality assessment method that could give the best performance in all situations, some multi-method fusion metrics were proposed. Machine learning techniques are often involved in such multi-method fusion metrics so that its output would be more consistent with human visual perceptions. On the other hand, the robustness and generalization ability of these multi-method fusion metrics are questioned because of the scarce of images with mean opinion scores. In order to comprehensively validate whether or not the generalization ability of such multi-method fusion IQA metrics are satisfying, we construct a new image database which contains up to 60 reference images. The newly built image database is then used to test the generalization ability of different multi-method fusion IQA metrics. Cross database validation experiment indicates that in our new image database, the performances of all the multi-method fusion IQA metrics have no statistical significant different with some single-method IQA metrics such as FSIM and MAD. In the end, a thorough analysis is given to explain why the performance of multi-method fusion IQA framework drop significantly in cross database validation.展开更多
This paper introduces a multi-granularity locking model (MGL) for concurrency control in object-oriented database system briefiy, and presents a MGL model formally. Four lockingscheduling algorithms for MGL are propos...This paper introduces a multi-granularity locking model (MGL) for concurrency control in object-oriented database system briefiy, and presents a MGL model formally. Four lockingscheduling algorithms for MGL are proposed in the paper. The ideas of single queue scheduling(SQS) and dual queue scheduling (DQS) are proposed and the algorithm and the performance evaluation for these two scheduling are presented in some paper. This paper describes a new idea of thescheduling for MGL, compatible requests first (CRF). Combining the new idea with SQS and DQS,we propose two new scheduling algorithms called CRFS and CRFD. After describing the simulationmodel, this paper illustrates the comparisons of the performance among these four algorithms. Asshown in the experiments, DQS has better performance than SQS, CRFD is better than DQS, CRFSperforms better than SQS, and CRFS is the best one of these four scheduling algorithms.展开更多
This paper proposes a novel indoor positioning scheme based on visible light communication(VLC).A new indoor VLC positioning scheme using fingerprint database with multi-parameters have been raised.We conduct simulati...This paper proposes a novel indoor positioning scheme based on visible light communication(VLC).A new indoor VLC positioning scheme using fingerprint database with multi-parameters have been raised.We conduct simulation and experimental research on the illumination intensity distribution of several direction parameters.In the experiment,four LED matrixes are identified by LED-ID with room dimensions of 3.75×4.00×2.7 m^3.The results show that the mean of the location error is 0.22 m in the receiving plane,verifying the correctness and feasibility of the positioning scheme.展开更多
Quantum private query(QPQ)protocols have emerged as a pivotal innovation in quantum cryptography,offering users the ability to retrieve specific database information while preserving privacy.However,the practical impl...Quantum private query(QPQ)protocols have emerged as a pivotal innovation in quantum cryptography,offering users the ability to retrieve specific database information while preserving privacy.However,the practical implementation of these protocols faces significant security challenges,particularly from joint-measurement attacks in multi-round query scenarios.A recent study by Liu et al.addresses these vulnerabilities through a comprehensive analysis and proposes innovative solutions,marking a critical advancement in the field[1].展开更多
为提高室内定位的精度和稳定度,提出了基于无迹卡尔曼滤波(Unscented Kalman Filtering,UKF),并融合蓝牙指纹库和行人航位推算(Pedestrian Dead Reckoning,PDR)的室内定位方法。首先,收集不同位置的信号强度数据,构建蓝牙指纹库。其次,...为提高室内定位的精度和稳定度,提出了基于无迹卡尔曼滤波(Unscented Kalman Filtering,UKF),并融合蓝牙指纹库和行人航位推算(Pedestrian Dead Reckoning,PDR)的室内定位方法。首先,收集不同位置的信号强度数据,构建蓝牙指纹库。其次,利用手机内置加速度计、陀螺仪等多传感器融合进行行人航位推算。在此基础上使用UKF进行融合,克服行人航位推算易产生累计误差的缺点,从而实现高精度室内定位,具有成本低、灵敏度高、稳定性好、定位方法简便等特点。最后,仿真实验结果表明了该方法的有效性。展开更多
In the video-based surveillance application, moving shadows can affect the correct localization and detection of moving objects. This paper aims to present a method for shadow detection and suppression used for moving...In the video-based surveillance application, moving shadows can affect the correct localization and detection of moving objects. This paper aims to present a method for shadow detection and suppression used for moving visual object detection. The major novelty of the shadow suppression is the integration of several features including photometric invariant color feature, motion edge feature, and spatial feature etc. By modifying process for false shadow detected, the averaging detection rate of moving object reaches above 90% in the test of Hall-Monitor sequence.展开更多
The Large Sky Area Multi-Object Fiber Spectroscopic Telescope (LAMOST, also called the Guo Shou Jing Telescope) is a special reflecting Schmidt telescope. LAMOST’s special design allows both a large aperture (effecti...The Large Sky Area Multi-Object Fiber Spectroscopic Telescope (LAMOST, also called the Guo Shou Jing Telescope) is a special reflecting Schmidt telescope. LAMOST’s special design allows both a large aperture (effective aperture of 3.6 m–4.9 m) and a wide field of view (FOV) (5°). It has an innovative active reflecting Schmidt configuration which continuously changes the mirror’s surface that adjusts during the observation process and combines thin deformable mirror active optics with segmented active optics. Its primary mirror (6.67m×6.05 m) and active Schmidt mirror (5.74m×4.40 m) are both segmented, and composed of 37 and 24 hexagonal sub-mirrors respectively. By using a parallel controllable fiber positioning technique, the focal surface of 1.75 m in diameter can accommodate 4000 optical fibers. Also, LAMOST has 16 spectrographs with 32 CCD cameras. LAMOST will be the telescope with the highest rate of spectral acquisition. As a national large scientific project, the LAMOST project was formally proposed in 1996, and approved by the Chinese government in 1997. The construction started in 2001, was completed in 2008 and passed the official acceptance in June 2009. The LAMOST pilot survey was started in October 2011 and the spectroscopic survey will launch in September 2012. Up to now, LAMOST has released more than 480 000 spectra of objects. LAMOST will make an important contribution to the study of the large-scale structure of the Universe, structure and evolution of the Galaxy, and cross-identification of multiwaveband properties in celestial objects.展开更多
Objective To compare the acute hemodynamic effects of five different pacing modes in patients with cardiac function NYHA class Ⅰ to Ⅱ without bundle branch block (BBB). Methods This study included 12 patients (SSS ...Objective To compare the acute hemodynamic effects of five different pacing modes in patients with cardiac function NYHA class Ⅰ to Ⅱ without bundle branch block (BBB). Methods This study included 12 patients (SSS 7, Ⅲ°AVB 5) undergoing pacemaker implantation. Right ventricular apex (RVA), right ventricular outflow tract (RVOT), right ventricular bifocal (RV-Bi), left ventricular base (LVB) and bi -ventricular (Bi-Ⅴ) pacing at 60 -80 ppm were done in VVI mode prior to implantation of DDD pacemaker. The cardiac index (CI), mean pulmonary artery pressure (mPAP) and pulmonary capillary wedge pressure (PCWP) were measured with Swan - Ganz thermodilution catheter after 5 minutes of each pacing mode. Results (1) Comparing to pacing at RVA (CI: 2. 41± 0. 38 L/min per m2, PCWP: 16. 7 ±3.3 mmHg), the CI increased and the PCWP decreased significantly in pacing at RVOT(CI: 2. 63 ± 0.46, PCWP: 13. 8±2. 3), LVB(CI: 2. 78±0.52, PCWP: 14. 4±3.1), RV-Bi(CI: 2. 83±0.57, PCWP: 12. 8± 2. 5) and Bi -Ⅴ pacing (CI: 2. 94± 0.60, PCWP: 12. 7±2. 5), P < 0. 01, respectively. (2) The CI of RV-Bi and Bi-Ⅴ pacing was higher than that of RVOT and LVB pacing, the PCWP was lower, P < 0. 05, respectively. (3) There was no significant difference between RV - Bi pacing and Bi-Ⅴ pacing in CI and PCWP. Conclusion There is no significant difference between RV - Bi pacing and Bi -V pacing in the acute hemodynamic effects; however,dual - site pacing is much better than single site pacing in that aspect for patients with cardiac function NYHA class Ⅰ to Ⅱ without BBB. Among single site pacing, the RVOT and LVB pacing is better than RVA pacing in cardiac function.展开更多
文摘This paper presents the basic concepts and principles,data structure and high efficient spatial index for multi_resolution image database.The database is characterized by arrangement of multi_resource image data and seamless mosaic,distribution_based storage and management,integration with other spatial database software such as GeoStar and GeoGrid developed by Wuhan Technical University of Surveying and Mapping.
基金supported by “the Fundamental Research Funds for the Central Universities” No.2018CUCTJ081
文摘Considering that there is no single full reference image quality assessment method that could give the best performance in all situations, some multi-method fusion metrics were proposed. Machine learning techniques are often involved in such multi-method fusion metrics so that its output would be more consistent with human visual perceptions. On the other hand, the robustness and generalization ability of these multi-method fusion metrics are questioned because of the scarce of images with mean opinion scores. In order to comprehensively validate whether or not the generalization ability of such multi-method fusion IQA metrics are satisfying, we construct a new image database which contains up to 60 reference images. The newly built image database is then used to test the generalization ability of different multi-method fusion IQA metrics. Cross database validation experiment indicates that in our new image database, the performances of all the multi-method fusion IQA metrics have no statistical significant different with some single-method IQA metrics such as FSIM and MAD. In the end, a thorough analysis is given to explain why the performance of multi-method fusion IQA framework drop significantly in cross database validation.
文摘This paper introduces a multi-granularity locking model (MGL) for concurrency control in object-oriented database system briefiy, and presents a MGL model formally. Four lockingscheduling algorithms for MGL are proposed in the paper. The ideas of single queue scheduling(SQS) and dual queue scheduling (DQS) are proposed and the algorithm and the performance evaluation for these two scheduling are presented in some paper. This paper describes a new idea of thescheduling for MGL, compatible requests first (CRF). Combining the new idea with SQS and DQS,we propose two new scheduling algorithms called CRFS and CRFD. After describing the simulationmodel, this paper illustrates the comparisons of the performance among these four algorithms. Asshown in the experiments, DQS has better performance than SQS, CRFD is better than DQS, CRFSperforms better than SQS, and CRFS is the best one of these four scheduling algorithms.
基金supported by ZTE Industry-Academia-Research Cooperation Funds under Grant No.2014ZTE02-12
文摘This paper proposes a novel indoor positioning scheme based on visible light communication(VLC).A new indoor VLC positioning scheme using fingerprint database with multi-parameters have been raised.We conduct simulation and experimental research on the illumination intensity distribution of several direction parameters.In the experiment,four LED matrixes are identified by LED-ID with room dimensions of 3.75×4.00×2.7 m^3.The results show that the mean of the location error is 0.22 m in the receiving plane,verifying the correctness and feasibility of the positioning scheme.
文摘Quantum private query(QPQ)protocols have emerged as a pivotal innovation in quantum cryptography,offering users the ability to retrieve specific database information while preserving privacy.However,the practical implementation of these protocols faces significant security challenges,particularly from joint-measurement attacks in multi-round query scenarios.A recent study by Liu et al.addresses these vulnerabilities through a comprehensive analysis and proposes innovative solutions,marking a critical advancement in the field[1].
文摘为提高室内定位的精度和稳定度,提出了基于无迹卡尔曼滤波(Unscented Kalman Filtering,UKF),并融合蓝牙指纹库和行人航位推算(Pedestrian Dead Reckoning,PDR)的室内定位方法。首先,收集不同位置的信号强度数据,构建蓝牙指纹库。其次,利用手机内置加速度计、陀螺仪等多传感器融合进行行人航位推算。在此基础上使用UKF进行融合,克服行人航位推算易产生累计误差的缺点,从而实现高精度室内定位,具有成本低、灵敏度高、稳定性好、定位方法简便等特点。最后,仿真实验结果表明了该方法的有效性。
文摘In the video-based surveillance application, moving shadows can affect the correct localization and detection of moving objects. This paper aims to present a method for shadow detection and suppression used for moving visual object detection. The major novelty of the shadow suppression is the integration of several features including photometric invariant color feature, motion edge feature, and spatial feature etc. By modifying process for false shadow detected, the averaging detection rate of moving object reaches above 90% in the test of Hall-Monitor sequence.
文摘The Large Sky Area Multi-Object Fiber Spectroscopic Telescope (LAMOST, also called the Guo Shou Jing Telescope) is a special reflecting Schmidt telescope. LAMOST’s special design allows both a large aperture (effective aperture of 3.6 m–4.9 m) and a wide field of view (FOV) (5°). It has an innovative active reflecting Schmidt configuration which continuously changes the mirror’s surface that adjusts during the observation process and combines thin deformable mirror active optics with segmented active optics. Its primary mirror (6.67m×6.05 m) and active Schmidt mirror (5.74m×4.40 m) are both segmented, and composed of 37 and 24 hexagonal sub-mirrors respectively. By using a parallel controllable fiber positioning technique, the focal surface of 1.75 m in diameter can accommodate 4000 optical fibers. Also, LAMOST has 16 spectrographs with 32 CCD cameras. LAMOST will be the telescope with the highest rate of spectral acquisition. As a national large scientific project, the LAMOST project was formally proposed in 1996, and approved by the Chinese government in 1997. The construction started in 2001, was completed in 2008 and passed the official acceptance in June 2009. The LAMOST pilot survey was started in October 2011 and the spectroscopic survey will launch in September 2012. Up to now, LAMOST has released more than 480 000 spectra of objects. LAMOST will make an important contribution to the study of the large-scale structure of the Universe, structure and evolution of the Galaxy, and cross-identification of multiwaveband properties in celestial objects.
文摘Objective To compare the acute hemodynamic effects of five different pacing modes in patients with cardiac function NYHA class Ⅰ to Ⅱ without bundle branch block (BBB). Methods This study included 12 patients (SSS 7, Ⅲ°AVB 5) undergoing pacemaker implantation. Right ventricular apex (RVA), right ventricular outflow tract (RVOT), right ventricular bifocal (RV-Bi), left ventricular base (LVB) and bi -ventricular (Bi-Ⅴ) pacing at 60 -80 ppm were done in VVI mode prior to implantation of DDD pacemaker. The cardiac index (CI), mean pulmonary artery pressure (mPAP) and pulmonary capillary wedge pressure (PCWP) were measured with Swan - Ganz thermodilution catheter after 5 minutes of each pacing mode. Results (1) Comparing to pacing at RVA (CI: 2. 41± 0. 38 L/min per m2, PCWP: 16. 7 ±3.3 mmHg), the CI increased and the PCWP decreased significantly in pacing at RVOT(CI: 2. 63 ± 0.46, PCWP: 13. 8±2. 3), LVB(CI: 2. 78±0.52, PCWP: 14. 4±3.1), RV-Bi(CI: 2. 83±0.57, PCWP: 12. 8± 2. 5) and Bi -Ⅴ pacing (CI: 2. 94± 0.60, PCWP: 12. 7±2. 5), P < 0. 01, respectively. (2) The CI of RV-Bi and Bi-Ⅴ pacing was higher than that of RVOT and LVB pacing, the PCWP was lower, P < 0. 05, respectively. (3) There was no significant difference between RV - Bi pacing and Bi-Ⅴ pacing in CI and PCWP. Conclusion There is no significant difference between RV - Bi pacing and Bi -V pacing in the acute hemodynamic effects; however,dual - site pacing is much better than single site pacing in that aspect for patients with cardiac function NYHA class Ⅰ to Ⅱ without BBB. Among single site pacing, the RVOT and LVB pacing is better than RVA pacing in cardiac function.