期刊文献+
共找到196篇文章
< 1 2 10 >
每页显示 20 50 100
Preliminary Tests of a Kerma-Area Product (KAP) Meter to Be Used as a Monitor Chamber in a Conventional Diagnostic X Ray System
1
作者 Eduardo Correa Regina Medeiros +4 位作者 Maria da Penha Potiens Vitor Vivolo Nathalia Costa Camila Murata Cristina Kikuti 《Journal of Modern Physics》 2015年第4期483-489,共7页
This study presents the results of the preliminary tests performed using a kerma-area product (KAP) meter in order to verify its usefulness as a monitor chamber in a clinical X ray system, which will be used in ioniza... This study presents the results of the preliminary tests performed using a kerma-area product (KAP) meter in order to verify its usefulness as a monitor chamber in a clinical X ray system, which will be used in ionization chambers’ quality control program. The tests performed were repeatability, surface measurement uniformity, linearity with tube current, measurement variation changing the distance and field size, KAP chamber radiation attenuation, and energy dependence. The KAP meter has presented a good repeatability (a maximum variation of 0.4%);its surface has a homogeneous response (a maximum variation of 1.0% among the different irradiated regions);the response is linear with the tube current and the variation of the PKA along the distance is less than 3.43%. On the other hand, the results obtained for chamber attenuation and energy dependence show that some corrections must be applied when the measurements are made. The results have shown a good performance of the KAP meter, confirming that it is possible to use this instrument as a monitor chamber. However, it is important to highlight that some correction factors for energy dependence and chamber radiation attenuation must be considered. 展开更多
关键词 KAP METER Quality Control DIAGNOSTIC RADIOLOGY monitor chamber
暂未订购
Collection efficiency of a monitor parallel plate ionization chamber for pencil beam scanning proton therapy 被引量:9
2
作者 Rong-Cheng Han Yong-Jiang Li Yue-Hu Pu 《Nuclear Science and Techniques》 SCIE CAS CSCD 2020年第2期1-10,共10页
The collection efficiency of monitor parallel plate ionization chambers is the main uncertainty in the beam control of pencil beam scanning systems.Existing calculation methods for collection efficiency in photon or p... The collection efficiency of monitor parallel plate ionization chambers is the main uncertainty in the beam control of pencil beam scanning systems.Existing calculation methods for collection efficiency in photon or passive scattering proton systems have not considered the characteristics of non-uniform charge density in pencil beam scanning systems.In this study,Boag’s theory was applied to a proton pencil beam scanning system.The transverse distribution of charge density in the ionization chamber was considered to be a Gaussian function and an analytical solution was derived to calculate collection efficiency in the beam spot area.This calculation method is called the integral method and it was used to investigate the effects of beam parameters on collection efficiency.It was determined that collection efficiency is positively correlated with applied voltage,beam size,and beam energy,but negatively correlated with beam current intensity.Additionally,it was confirmed that collection efficiency is improved when the air filling the monitor parallel plate ionization chamber is replaced with nitrogen. 展开更多
关键词 Collection efficiency monitor ionization chamber Pencil beam scanning Proton therapy
暂未订购
The Calibration and Use of a New Ring-Shaped Ionization Chamber for Monitoring and Dosimetry of X-Ray Beams
3
作者 Babak Sharifi Hossein Zamani Zeinali +2 位作者 Anita Alipoor Arjang Shahvar Ali Negarestani 《World Journal of Nuclear Science and Technology》 2015年第3期200-207,共8页
Today, dosimeters are used generally for dosimetry of the diagnostic X-ray beam. Ionization chambers are appropriate instruments for monitoring and also the dosimetry of X-ray beam in medical diagnostic equipment. The... Today, dosimeters are used generally for dosimetry of the diagnostic X-ray beam. Ionization chambers are appropriate instruments for monitoring and also the dosimetry of X-ray beam in medical diagnostic equipment. The present work introduces design and investigation of a new ring-shaped monitor chamber with a PMMA body, graphite-coated PMMA windows (0.5 mm thick), a special graphite-foil central electrode (0.1 mm thick, 0.7 g/cm3 dense) that creating two sensitive volumes and a central hole for crossing the radiation beam with less attenuation. The results of performance tests conducted at the Nuclear Science and Technology Research Institute, AEOI in Karaj- Iran proved the high short and long-term stability, the very low leakage current, the low directional dependence and very high ion collection efficiency through the special design of the collecting electrode. Moreover, the FLUKA Monte Carlo simulations certified the negligible effect of central electrode on this new ring-shaped monitor chamber. According to the results of the performance tests, the new monitor chamber can be used as a standard dosimeter in order to monitor X-ray beam in primary standard dosimetry laboratories. 展开更多
关键词 Ring-Shaped monitor chamber Diagnostic X-RAY Beam Quality Control Tests Low DENS Graphite-Foil Central Electrode
暂未订购
新建铁路隧道超近距下穿运营高速公路施工力学特性研究
4
作者 张行 习春飞 +2 位作者 王星 黄帅 孙巍锋 《路基工程》 2026年第1期93-98,共6页
针对某在建隧道超近距下穿既有高速施工,提出φ159×9mm大直径长管棚预支护进洞,联合小洞室异步开挖+双层初期支护的施工技术方案,采用数值模拟及现场实测开展施工力学特性研究。结果表明:随施工开挖逐步推进,管棚内力自拱顶至拱肩... 针对某在建隧道超近距下穿既有高速施工,提出φ159×9mm大直径长管棚预支护进洞,联合小洞室异步开挖+双层初期支护的施工技术方案,采用数值模拟及现场实测开展施工力学特性研究。结果表明:随施工开挖逐步推进,管棚内力自拱顶至拱肩呈不断减小趋势,拱顶位置管棚应力最大,其峰值应力为11.20MPa,拱肩B、C、D位置峰值应力为10.90、8.40、4.60MPa;初支结构拱顶、拱肩、拱腰至拱底处应力均先缓慢增加,在急剧增大后趋于稳定,施工期间初支结构应力峰值稳定于1.48MPa,沉降变形量最大为10.8mm;初支结构测点峰值应力1.60MPa,拱腰位置结构应力相对较小,其峰值应力约1.00MPa,拱顶位置沉降峰值8.7mm。 展开更多
关键词 黄河沿岸 超浅埋 近接下穿 小洞室施工 异步开挖 双层支护 位移监测 变形控制
在线阅读 下载PDF
颗粒物恒温恒湿称重舱参数数字化监控系统设计
5
作者 李鸿博 彭程 《仪表技术》 2026年第1期5-8,41,共5页
针对汽车尾气颗粒物称重环境舱参数监控需求,设计并实现了一套基于软硬件协同的数字化监控系统,以解决传统方案数据可读性差、存储能力有限及功能缺失等问题。系统采用TD-4017+模拟量采集模块,通过Modbus-RTU RS-485协议实现高精度数据... 针对汽车尾气颗粒物称重环境舱参数监控需求,设计并实现了一套基于软硬件协同的数字化监控系统,以解决传统方案数据可读性差、存储能力有限及功能缺失等问题。系统采用TD-4017+模拟量采集模块,通过Modbus-RTU RS-485协议实现高精度数据采集(采样误差≤0.1%),并基于Python GUI(PySide6)开发上位机软件,集成实时监测、超限报警(声光提示)、MySQL数据库存储及PDF报告自动生成等功能。关键技术包括多线程数据采集、电压-物理量转换算法及双层级故障诊断机制。实际测试表明,系统可实现稳定数据采集、0.5 s内快速报警响应,并具备完整的历史数据追溯能力。相较于传统方案,该系统显著提升了监测精度与自动化水平,为颗粒物排放检测的合规性提供了可靠技术支撑,具有较高的工程应用与推广价值。 展开更多
关键词 颗粒物称重 环境舱监控 数据可视化
原文传递
Development of a novel system for monitoring tritium in gaseous form 被引量:1
6
作者 陈志林 彭述明 +3 位作者 陈华 常瑞敏 孟丹 穆龙 《Nuclear Science and Techniques》 SCIE CAS CSCD 2015年第2期67-70,共4页
Tritium real-time measurement in glovebox or workplace is important to ensure safe operation of tritium. A novel tritium monitor system including an open-walled ionization chamber, an electrometer and an IPC(Industria... Tritium real-time measurement in glovebox or workplace is important to ensure safe operation of tritium. A novel tritium monitor system including an open-walled ionization chamber, an electrometer and an IPC(Industrial Personal Computer) has been developed to measure tritium in gaseous form. Using mesh walls, instead of sealed wall, the open-walled ionization chamber has less tritium absorption and lower memory effect. In addition, tritium gas can diffuse into the chamber's sensitive region without the assistant of sampling system and ion trap, which are installed at the front-end of commonly used flow-through ionization chambers. Background signal of this monitor system is about 3.7 × 105Bq/m3, and after exposed to tritium concentration at about 1011Bq/m3 for 4h, background of the monitor can recover after purging it several times with dry air. It is suitable for longtime tritium measurements in both glovebox and workplace. 展开更多
关键词 监控系统 氚气 气态 开发 工业个人计算机 监测 实时测量 电离室
在线阅读 下载PDF
Fusion Neutron Flux Monitor for ITER 被引量:2
7
作者 杨进蔚 杨青巍 +3 位作者 肖功珊 张炜 宋先瑛 李旭 《Plasma Science and Technology》 SCIE EI CAS CSCD 2008年第2期141-147,共7页
Neutron flux monitor (NFM) as an important diagnostic sub-system in ITER (international thermonuclear experimental reactor) provides a global neutron source intensity, fusion power and neutron flux in real time. T... Neutron flux monitor (NFM) as an important diagnostic sub-system in ITER (international thermonuclear experimental reactor) provides a global neutron source intensity, fusion power and neutron flux in real time. Three types of neutron flux monitor assemblies with different sensitivities and shielding materials have been designed. Through MCNP (Mante-Carlo neutral particle transport code) calculations, this extended system of NFM can detect the neutron flux in a range of 10^4 n/(cm^2.s) to 10^14 n/(cm^2.s). It is capable of providing accurate neutron yield measurements for all operational modes encountered in the ITER experiments including the in-situ calibration. Combining both the counting mode and Campbelling (MSV; Mean Square Voltage) mode in the signal processing units, the requirement of the dynamic range (107) for these NFMs and time resolution (1 ms) can be met. Based on a uncertainty analysis, the estimated absolute measurement accuracies of the total fusion neutron yield can reach the required 10% level in both the early stage of the DD-phase and the DD-phase, the absolute measurement accuracy full power DT operation mode. In the advanced would be better than 20%. 展开更多
关键词 neutron flux monitor international thermonuclear experimental reactor(ITER) assembly of fission chamber
在线阅读 下载PDF
高低温试验箱数字孪生系统构建方法
8
作者 陈清华 梁作友 +2 位作者 关维娟 季家东 刘萍 《系统仿真学报》 北大核心 2025年第6期1400-1411,共12页
针对高低温试验箱数字孪生系统构建需求,采用以MQTT为通信协议的EMQX服务器进行数据传输,在实时数据驱动下,实现物理实体和虚拟模型实时动态交互映射,并利用神经网络模型和遗传算法对设备运行状态进行评估、预测及提供系统调整策略,实... 针对高低温试验箱数字孪生系统构建需求,采用以MQTT为通信协议的EMQX服务器进行数据传输,在实时数据驱动下,实现物理实体和虚拟模型实时动态交互映射,并利用神经网络模型和遗传算法对设备运行状态进行评估、预测及提供系统调整策略,实现工作人员全气候、全寿命、全工况了解设备运行状态,有效保障高低温试验箱的安全可靠运行。 展开更多
关键词 数字孪生 高低温试验箱 动态映射 虚实交互 综合监测
原文传递
核电站流出液γ核素在线监测系统优化设计
9
作者 田锦 赵修良 +2 位作者 屈国普 魏岐桉 贺三军 《核电子学与探测技术》 北大核心 2025年第8期1173-1178,共6页
利用MCNP优化设计核电站γ放射性核素在线监测系统。综合考虑环境本底、探测效率、测量时间及经济性确定了取样容器和屏蔽铅室等相关参数,通过代入优化后的参数计算得到6 h测量时间下系统对水体常见核素131I、137Cs、60Co、40K的探测下... 利用MCNP优化设计核电站γ放射性核素在线监测系统。综合考虑环境本底、探测效率、测量时间及经济性确定了取样容器和屏蔽铅室等相关参数,通过代入优化后的参数计算得到6 h测量时间下系统对水体常见核素131I、137Cs、60Co、40K的探测下限,结果分别为4.56×10^(-4) Bq/L、5.63×10^(-4) Bq/L、3.97×10^(-3) Bq/L、4.48×10^(-2) Bq/L。仿真结果表明该系统在中低能γ核素监测方面性能优异且能够达到更低探测下限,可为高灵敏度核电站废水排放监测提供参考。 展开更多
关键词 核电站流出液 Γ放射性核素 核素监测 取样容器 屏蔽室
在线阅读 下载PDF
基于数字孪生的船舶发动机燃烧室故障检测系统
10
作者 陆旭昇 翁胜伟 +1 位作者 杜守志 王忠诚 《舰船科学技术》 北大核心 2025年第21期183-189,共7页
随着船舶设备复杂度的增加,为提高船舶运营安全性和效率,基于数字孪生技术开发发动机燃烧室状态监测和故障检测系统,采用微服务器架构和前后端分离模式开发。前端以HTML、Vue.js搭建用户交互界面,业务逻辑层用Java开发,同时用Blender软... 随着船舶设备复杂度的增加,为提高船舶运营安全性和效率,基于数字孪生技术开发发动机燃烧室状态监测和故障检测系统,采用微服务器架构和前后端分离模式开发。前端以HTML、Vue.js搭建用户交互界面,业务逻辑层用Java开发,同时用Blender软件创建船舶柴油发动机的数字孪生映射结构模型,通过WebGL展示其3D模型、运行状态和相关数据。系统集成多种传感器,实时采集发动机温度、压力、振动等数据,运用大数据分析与迁移学习算法进行故障模式识别,结合历史数据与实时信息预测潜在故障并预警。试验验证显示,该系统能有效提升船舶设备的安全性和可靠性,为船舶智能化管理提供技术支撑。 展开更多
关键词 数字孪生 船舶燃烧室 状态监测 故障检测 迁移学习
在线阅读 下载PDF
连掘工作面移变硐室设计安装应用研究
11
作者 刘兆祥 卞涛 《中国矿业》 北大核心 2025年第S2期584-587,共4页
为了规范现代化大型矿井掘进工作面移变硐室的安装与布置,统一提高移变硐室安装标准,本文研究了神东煤炭集团补连塔煤矿连掘工作面移变硐室各类开关的选型与安装、监测监控系统的设计安装、智能矿山的设计安装及图牌板要求。研究结果表... 为了规范现代化大型矿井掘进工作面移变硐室的安装与布置,统一提高移变硐室安装标准,本文研究了神东煤炭集团补连塔煤矿连掘工作面移变硐室各类开关的选型与安装、监测监控系统的设计安装、智能矿山的设计安装及图牌板要求。研究结果表明,矿井连掘工作面移变硐室的规范安装尤为重要,移变、馈电、风机开关的选型、位置安装都有严格要求,监测监控系统必须满足国家安全规定,智能化矿山4G与数据上传须标准化安装,一个规范标准的移变硐室有利于安全用电,推动煤矿安全发展。 展开更多
关键词 移变硐室 智能化 监测监控 供电 标准化安装
在线阅读 下载PDF
内外置电极ECT传感器激励方式研究
12
作者 马敏 李斌洲 《计量学报》 北大核心 2025年第7期1012-1020,共9页
目前,航空发动机燃烧室的内部状态尚无有效的监测方法。为此,探索利用电容层析成像技术(ECT)实现对航空发动机燃烧室内部状态进行监测这一难题。针对燃烧室环形空间,设计了内外置电极ECT传感器,提出了6种激励测量方式,以灵敏场的均匀性... 目前,航空发动机燃烧室的内部状态尚无有效的监测方法。为此,探索利用电容层析成像技术(ECT)实现对航空发动机燃烧室内部状态进行监测这一难题。针对燃烧室环形空间,设计了内外置电极ECT传感器,提出了6种激励测量方式,以灵敏场的均匀性等5个指标作为评价标准,寻求最佳激励策略的同时研究了双电极激励中激励电极间距对测量过程和成像结果的影响。实验结果表明,间隔1电极激励方式图像相关系数最高可达0.9645,整体效果最优,为下一步传感器激励方式的选择提供了依据。 展开更多
关键词 电容层析成像 燃烧室监测 图像重建 内外置电极 火焰测量 激励策略
在线阅读 下载PDF
高能X射线FLASH放射治疗:基于低气压电离室的束流监视器物理及性能
13
作者 赵继荣 羊奕伟 +2 位作者 张毅 王诗岚 冯松 《物理学报》 北大核心 2025年第14期360-368,共9页
超高剂量率X射线(简称XFLASH)的剂量实时准确监测在XFLASH放射治疗临床前后都起着关键作用.本文研究了一种用于XFLASH放射治疗剂量在线监测的低气压电离室(LPIC),并将其作为XFLASH束流的监视器.开展了电离室物理设计,两个独立腔室分别... 超高剂量率X射线(简称XFLASH)的剂量实时准确监测在XFLASH放射治疗临床前后都起着关键作用.本文研究了一种用于XFLASH放射治疗剂量在线监测的低气压电离室(LPIC),并将其作为XFLASH束流的监视器.开展了电离室物理设计,两个独立腔室分别放置高压极、收集极和保护极.高压极与收集极电极间距为1 mm,腔室气压约5 kPa.实验分析了该监视器的坪曲线、剂量重复性、剂量线性等性能.测试结果表明,研制的低气压电离室表现出优异的剂量线性(R^(2)>0.999)和剂量重复性(变异系数小于0.5%),被证明是一种可靠的剂量监视器,其性能满足国家标准对放射治疗剂量监视系统的要求. 展开更多
关键词 FLASH放射治疗 低气压电离室 束流监视器 性能测试
暂未订购
地下井室可燃气体监测仪性能检测分析 被引量:1
14
作者 时丽艳 翟羽佳 +2 位作者 李尧 王欣新 韩江振 《仪表技术》 2025年第3期53-56,60,共5页
针对地下井室可燃气体监测仪的性能评价,选取了6台设备,从示值误差、报警点示值误差、重复性、静电放电抗扰性、环境适应性、辐射电磁场抗扰性及响应时间等7个方面进行系统性检测研究。检测结果表明,该类监测仪在各项性能指标上均符合... 针对地下井室可燃气体监测仪的性能评价,选取了6台设备,从示值误差、报警点示值误差、重复性、静电放电抗扰性、环境适应性、辐射电磁场抗扰性及响应时间等7个方面进行系统性检测研究。检测结果表明,该类监测仪在各项性能指标上均符合地下井室可燃气体监测的技术要求,能够为安全生产提供可靠保障。研究结果不仅验证了监测仪的实际应用性能,还为其计量溯源提供了科学依据和技术支持。 展开更多
关键词 地下井室 可燃气体 监测仪 计量溯源 性能检测
原文传递
国控大气辐射环境自动监测站测量设备现场校准
15
作者 李少婷 肖李翔 +2 位作者 江淑瑜 代传波 郑文祥 《中国辐射卫生》 2025年第3期402-407,共6页
目的 对国控大气辐射环境自动连续监测站中的高压电离室和NaI(Tl) γ谱仪进行现场校准,验证辐射环境在线监测系统的可靠性。方法 采用^(137)Cs、^(60)Co、^(241)Am作为γ参考辐射源,对湖北省内9个国控大气辐射环境自动监测站高压电离室... 目的 对国控大气辐射环境自动连续监测站中的高压电离室和NaI(Tl) γ谱仪进行现场校准,验证辐射环境在线监测系统的可靠性。方法 采用^(137)Cs、^(60)Co、^(241)Am作为γ参考辐射源,对湖北省内9个国控大气辐射环境自动监测站高压电离室的本底、响应和重复性等计量性能进行测量,并将剂量率与湿度进行了相关性分析,对NaI(Tl) γ谱仪能量分辨力和活度响应等计量性能进行测试。结果 测试的9个国控大气辐射环境自动监测站中,高压电离室本底范围在58.2~82.6 nGy/h之间,响应结果范围在0.94~1.08之间,满足通常为1.0±0.2的要求;重复性在0.43%~3.80%之间,满足不超过10%的要求;剂量率与湿度显著相关,相关系数为0.447 6;NaI(Tl) γ谱仪能量分辨力范围在6.8%~7.9%之间,满足对137Cs核素661.7 keV能量分辨力不超过9%的要求;NaI(Tl) γ谱仪对241Am活度响应在(1.4%~1.8%) s^(-1)·Bq^(-1)之间,对60Co活度响应在(6.6‰~8.4‰)s^(-1)·Bq^(-1)之间。结论 9个国控大气辐射环境自动监测站在线监测系统稳定可靠,可为公众了解辐射环境状况提供辐射环境监测信息。 展开更多
关键词 自动监测站 高压电离室 NaI(Tl)谱仪 现场校准
原文传递
核电厂控制室可居留监测电离室与保护功能设计优化
16
作者 李中 《核电子学与探测技术》 北大核心 2025年第11期1722-1727,共6页
针对核电厂控制室通风系统中原辐射仪表故障率高、误报警频繁触发应急通风等问题,分析原电离室仪表设计原理,从电离室探测器、前置放大电路、信号处理算法及DCS保护逻辑等方面,提出相应优化设计方案。目前武汉厂家高气压电离室产品已在... 针对核电厂控制室通风系统中原辐射仪表故障率高、误报警频繁触发应急通风等问题,分析原电离室仪表设计原理,从电离室探测器、前置放大电路、信号处理算法及DCS保护逻辑等方面,提出相应优化设计方案。目前武汉厂家高气压电离室产品已在部分电厂替代原仪表,田湾核电实施保护逻辑优化后运行稳定。 展开更多
关键词 电离室 剂量率监测 保护逻辑 优化
在线阅读 下载PDF
考虑多传感融合的跳汰机空气室水位在线监测
17
作者 兰小进 牛超 +2 位作者 陈飞云 许瑞鹏 于子一 《洁净煤技术》 北大核心 2025年第S1期926-930,共5页
为了能够实时且精准监测跳汰机空气室水位的变化情况,提出一种考虑多传感融合的跳汰机空气室水位在线监测方法。首先,在跳汰机空气室展开水位监测传感器部署。其次,通过卡尔曼滤波算法的状态估计特性和相关历史信息,使状态的估计值更加... 为了能够实时且精准监测跳汰机空气室水位的变化情况,提出一种考虑多传感融合的跳汰机空气室水位在线监测方法。首先,在跳汰机空气室展开水位监测传感器部署。其次,通过卡尔曼滤波算法的状态估计特性和相关历史信息,使状态的估计值更加逼近真实值,完成多传感动态数据融合。考虑到传感器数据出现严重冲突时,造成数据融合结果偏离真实值。引入D-S理论,通过冲突因子量化数据间的不一致性,采用改进的组合规则重新分配冲突数据权重,在决策层对卡尔曼滤波的初步融合结果展开仲裁,实现冲突数据决策。最后,应用改进随机森林算法完成跳汰机空气室水位在线监测。实验研究表明,应用所提方法可以获取更加准确的跳汰机空气室水位在线监测结果。 展开更多
关键词 多传感融合 跳汰机空气室 水位 在线监测
在线阅读 下载PDF
基于CNN-LSTM-Attention模型的超大型船坞坞室基坑围护变形预测分析 被引量:1
18
作者 闫瑞海 《岩土工程技术》 2025年第6期854-864,共11页
某超大型船坞坞室基坑采用锚碇式组合钢板桩围护体系。为研究基坑变形规律,对坞墙承台、组合钢板桩、锚碇墙等围护结构进行沉降、水平位移和受力监测,分析其变化趋势、原因及时空关联性。结果表明,采用无内支撑组合钢板桩的船坞坞室围... 某超大型船坞坞室基坑采用锚碇式组合钢板桩围护体系。为研究基坑变形规律,对坞墙承台、组合钢板桩、锚碇墙等围护结构进行沉降、水平位移和受力监测,分析其变化趋势、原因及时空关联性。结果表明,采用无内支撑组合钢板桩的船坞坞室围护设计,受软土特性和降水影响,其围护结构顶部沉降和水平位移、组合钢板桩深层水平位移在开挖过程中变形较大,各监测项目数据变化具有较强的时空关联效应。建立了一种可以提取监测时序数据关键特征的CNN-LSTM-Attention组合神经网络模型,以不同监测项目的监测数据作为模型输入,经过CNN神经网络卷积运算、LSTM神经网络回归预测、Attention注意力权重分配、全连接层等操作输出预测值,并与实测数据对比分析。根据试验结果,引入注意力机制的CNN-LSTM-Attention的组合模型,比LSTM模型和BiLSTM模型预测精度更高,且在相邻监测点的预测中,该模型适用性良好,验证了监测点数据变化趋势具有较强的空间相关性。 展开更多
关键词 船坞坞室 组合钢板桩 变形监测 特性分析 预测模型
在线阅读 下载PDF
浅析输气管道阀室常见供电方案
19
作者 王静 尹贻功 +1 位作者 马雪莉 刘建春 《石油工业技术监督》 2025年第7期52-56,共5页
随着长输管道安全管理要求的提高和企业自动化运营管理模式的升级,普通阀室已不能满足管道沿线数据采集和监控管理需求,越来越多的阀室被改造为监视阀室和监控阀室。通过立足监视、监控阀室的功能定位,开展了阀室负荷分析,综合比选了外... 随着长输管道安全管理要求的提高和企业自动化运营管理模式的升级,普通阀室已不能满足管道沿线数据采集和监控管理需求,越来越多的阀室被改造为监视阀室和监控阀室。通过立足监视、监控阀室的功能定位,开展了阀室负荷分析,综合比选了外部电网供电、太阳能供电、燃气发电机供电等3种供电方案,并给出了比选建议。 展开更多
关键词 长输管道 阀室 监视 监控 供电方案
在线阅读 下载PDF
融合多传感特征的中压SF_(6)环网柜气室局部放电诊断及定位方法 被引量:1
20
作者 林贞荣 《电工技术》 2025年第6期84-86,93,共4页
中压SF_(6)环网柜气室中存在各种电磁噪声,在监测过程中可能会将其误判为局部放电信号,产生误报。通过布设多个传感器对环网柜多源的数据进行采集,并将采集到的数据进行局部放电信号特征提取,以此实现中压SF_(6)环网柜气室局部放电的实... 中压SF_(6)环网柜气室中存在各种电磁噪声,在监测过程中可能会将其误判为局部放电信号,产生误报。通过布设多个传感器对环网柜多源的数据进行采集,并将采集到的数据进行局部放电信号特征提取,以此实现中压SF_(6)环网柜气室局部放电的实时监测。测试结果表明,所提方法的误报率和漏报率能够控制在1%以内,证明所提方法能够及时发现局部放电现象,提高中压SF_(6)环网柜的安全性。 展开更多
关键词 中压 SF_(6)气体 环网柜 气室 局部放电 实时监测
在线阅读 下载PDF
上一页 1 2 10 下一页 到第