期刊文献+
共找到883篇文章
< 1 2 45 >
每页显示 20 50 100
Corporoplasty with small soft axial prostheses (VIRILIS ) and bovine pericardial graft (HYDRIX) in Peyronie's disease 被引量:6
1
作者 Alessandro Zucchi Mauro Silvani Stefano Pecoraro 《Asian Journal of Andrology》 SCIE CAS CSCD 2013年第2期275-279,I0009,共6页
The surgical techniques used by Austoni and Egydio in the treatment of Peyronie's disease are based on geometric principles. The aim of this paper is to report our multicentric experience and technical changes to Aus... The surgical techniques used by Austoni and Egydio in the treatment of Peyronie's disease are based on geometric principles. The aim of this paper is to report our multicentric experience and technical changes to Austoni's original technique, focusing on several tips and tricks to make this technique easy to perform, even by less experienced practitioners. We performed operations in three different Italian institutions. We implanted a small soft Virilis I~ axial prostheses (Ф 7 Fr.), using a bovine pericardium collagen matrix patch (Hydrix) to cover the defect in the tunica albuginea. Sixty patients with a mean age of 58 years (range 44-76 years) underwent surgery between September 2005 and January 2010. After surgery, mean lengthening of the shaft was 2 cm (range 1.2-2.3 cm) with complete correction of penile recurvatum. Thirty-nine patients resumed sexual activity 60 days later, 14 after 90 days and 7 after 120 days. The international index of erectile function (IIEF) score was 15.5 before surgery and it improved to 23 at 12 and 24 months after surgery. Furthermore, the visual analogue scale (VAS) showed good results in terms of the recovery of natural sexual intercourse (over 80% of couples) and of the original length and girth of the penis. The soft implant we used takes advantage of erection that occurs spontaneously, using the residual erection of the spared cavernous tissue. The method is easy to learn and reproducible, and the use of pericardium speeds up the operation, while also covering large defects of the tunica albuginea that result from complex recurvatum. 展开更多
关键词 implants PENIS pericardial graft Peyronie's disease prostheses
暂未订购
Microstructure and dry wear properties of Ti-Nb alloys for dental prostheses 被引量:2
2
作者 徐丽娟 肖树龙 +2 位作者 田竟 陈玉勇 黄玉东 《中国有色金属学会会刊:英文版》 CSCD 2009年第S3期639-644,共6页
The microstructure and properties of a series of binary Ti-Nb alloys for dental prostheses with niobium contents ranging from 5% to 20% were investigated. The experimental results indicate that the crystal structure a... The microstructure and properties of a series of binary Ti-Nb alloys for dental prostheses with niobium contents ranging from 5% to 20% were investigated. The experimental results indicate that the crystal structure and morphology of Ti-Nb alloys are sensitive to their niobium contents. When Nb content is 5%, the acicular α crystal grain is observed. When Nb content is 10%, the coarse equiaxed crystal grain and the fine, acicular α crystal grain are observed. When Nb content is 15%, only the α equiaxed crystal grain is observed. When the alloy contains 20%Nb, the equiaxed and dendritic α crystal grain are observed. For Ti-Nb alloys, the increase of Nb content modifies the microstructure of Ti-Nb alloys significantly and decreases their compression elastic modulus, in which Ti-20Nb alloy shows the largest compression strength and Ti-5Nb alloy shows the best plasticity. The dry wear resistance of Ti-Nb alloys against Gr15 ball was investigated on CJS111A ball-disk wear instrument. For Ti-Nb alloys, Ti-10Nb alloy shows a smallest steady friction coefficient, Ti-5Nb alloy shows the smallest wear depth and best wear resistance, and Ti-15Nb alloy shows the largest wear depth and worst wear resistance. The phenomenon of furrow cut happens and furrows form during wear tests. 展开更多
关键词 TI-NB alloy MICROSTRUCTURE DRY WEAR resistance DENTAL prostheses material
在线阅读 下载PDF
Neural prostheses for restoring functions lost after spinal cord injury 被引量:2
3
作者 Marc Fakhoury 《Neural Regeneration Research》 SCIE CAS CSCD 2015年第10期1594-1595,共2页
Spinal cord injury(SCI)is a debilitating condition that affects more than 2.5 million individuals worldwide(Thuret et al.,2006).In addition to its devastating effects on the individual,this disease is a heavy burd... Spinal cord injury(SCI)is a debilitating condition that affects more than 2.5 million individuals worldwide(Thuret et al.,2006).In addition to its devastating effects on the individual,this disease is a heavy burden to the society in terms of health care costs, which are estimated in billions of dollars annually in most developed countries (Cadotte and Fehlings, 2011). 展开更多
关键词 MORE SCI Neural prostheses for restoring functions lost after spinal cord injury
暂未订购
Comparison of the Radial Compliance of Three Kinds of Vascular Prostheses and Pig′s Carotid Based on Dynamic-simulated Condition 被引量:4
4
作者 SHEN Gao-tian LIN Jing +1 位作者 ZHANG Hong-qi WANG Lu 《Chinese Journal of Biomedical Engineering(English Edition)》 2012年第3期104-109,共6页
There are some problems in the vascular prostheses, which influence the health of the patients. This paper aims to the radial compliance of three kinds of vascular prostheses and the pig's carotid based on the dynami... There are some problems in the vascular prostheses, which influence the health of the patients. This paper aims to the radial compliance of three kinds of vascular prostheses and the pig's carotid based on the dynamic-simulated condition. The radial compliance of knitted structure vascular prostheses with crimps ranged from 2.52% to 0.94%/100 mmHg, which was superior to e-FFFE and woven prostheses', ranged from 0.73% to 0.31%/100 mmHg and from 0.81% to 0.22%/100 mmHg. But comparing with the radial compliance of pig's carotid, ranged from 7.21% to 10.04% /100 mmHg, there was a big gap between them. And also the trend of the radial compliance of vascular prostheses was different from the real pig's carotid. There is a lot of work left to improve the radial compliance, not only to change the vascular prostheses' compliance, but also to meet with the real vascular. 展开更多
关键词 radial compliance vascular prostheses dynamic-simulated pig'scarotid
在线阅读 下载PDF
Preparation and Mechanical Performance of Blended Polyester/Silk Small Diameter Arterial Prostheses
5
作者 杨小元 王璐 +2 位作者 关国平 关颖 KING W Martin 《Journal of Donghua University(English Edition)》 EI CAS 2013年第5期356-358,共3页
Small diameter arterial prostheses were required to treat coronary and cerebrovascular arterial diseases. The diameters of the artificial blood vessels should match the diameters of the host arteries. Besides,the mech... Small diameter arterial prostheses were required to treat coronary and cerebrovascular arterial diseases. The diameters of the artificial blood vessels should match the diameters of the host arteries. Besides,the mechanical properties of the arterial prostheses should be strong enough to endure the forces in the body after implantation. In this study,silk and polyester were woven into small diameter arterial prostheses and the dimensional and mechanical properties,as well as the water permeability,were investigated. The woven samples had an inner diameter ranging from 3. 65 to 3. 94mm. The wall thickness of the samples ranged from 0. 26 to 0. 28mm. Compared with polytetrafiuoroethylene( ePTFE) commercial devices,whose probe bursting strength was measured to be 15. 64 N /mm2,the woven samples had superior strength values ranging from20. 53 to 28. 97 N /mm2. In addition,the radial compliance of the woven samples was found to lie between the ePTFE sample and the pig's carotid artery,and the water permeability of all the woven samples was less than 300 mL /( cm2·min) which indicated that these woven samples could be implanted without preclotting. 展开更多
关键词 SILK polyester woven ARTERIAL prostheses mechanical properties
在线阅读 下载PDF
New Design of Textile Vascular Prostheses for the Reconstruction of Small Diameter Vascular Blood Vessels
6
作者 CHRZANOWSKA Olga STRUSZCZYK Marcin Henryk KRUCINSKA Izabella 《Journal of Donghua University(English Edition)》 EI CAS 2013年第5期401-405,共5页
The general object of research is to design new idea of the semi-biodegradable,multilayered vascular prosthesis used for the reconstruction of significantly small diameter vascular vessels( microreconstruction). The p... The general object of research is to design new idea of the semi-biodegradable,multilayered vascular prosthesis used for the reconstruction of significantly small diameter vascular vessels( microreconstruction). The paper studies the selection of appropriate sterilization technique for resorbable tubular structures made of poly( L-lactide-co-glicolide)( PLAGA) and nonbiodegradable tubular structures made of polypropylene( PP). The designed grafts are characterized by the physical properties as well as mechanical properties according to ISO 7198 ∶ 1998 Standard.Moreover,the process of the grafts fabrication will be explained considering the stages affected the critical properties of the elaborated textile implants. The increase of PLAGA melt-electrospun tubular structures mechanical properties was observed due to the thermal stabilization use. The ethylene oxide( EO) and steam sterilization had a destructive effect on the designed PLAGA meltelectrospun tubular, fibrous structures, whereas the irradiation yielded in the changes in mechanical and physical properties on the acceptable level,taking into account the future clinical applications. 展开更多
关键词 VASCULAR prostheses melt-electrospinning MELT-BLOWN STERILIZATION
在线阅读 下载PDF
Binding mechanism of interface of porous coated titanium alloy prostheses
7
作者 邹宏思 叶军 +1 位作者 唐农轩 袁存华 《Journal of Medical Colleges of PLA(China)》 CAS 1996年第1期14-17,21,共5页
In the experiment, we inserted the implants coated with TC4 fibers and particles into the bones of dogs.The histological characters of the bone ingrowth and the state of bone remodelling at interface were observed. An... In the experiment, we inserted the implants coated with TC4 fibers and particles into the bones of dogs.The histological characters of the bone ingrowth and the state of bone remodelling at interface were observed. And then the whole course of the fatigue injuries accumulation at the interface was monitored by scanning electron microscopy equipped with fatigue stage. Experiments show that the collagen fibers of bone interweave in the porosity of implants, which were strengthened by hydroxyapatite crystal. The collagen fibers were bound to the porous layer implant and the binding strength was enhanced by hydroxyapatite crystal. The remodelling state of bone in pores of implant and around the interface play a key role in determining the fatigue strength and the life span of the interface between bone and implant. Therefore, we consider that the interlocking fixation between bone and implant can be more exactly explained as binding mechanism. 展开更多
关键词 porous-coated prostheses INTERLOCKING FIXATION binding mechanism
暂未订购
Anatomical and Functional Preliminary Results of Total Non-Cemented Hip Prostheses
8
作者 A. M. Abdoul Wahab M. Koini +4 位作者 B. Dembele A. D. Sane A. N’Diaye C. Dieme N. F. Coulibaly 《Open Journal of Orthopedics》 2017年第10期329-336,共8页
The aim of this work was to assess the preliminary anatomical and functional results of patients to establish prospects. Materials and method: We report here the preliminary results of a retrospective mono-centric, ho... The aim of this work was to assess the preliminary anatomical and functional results of patients to establish prospects. Materials and method: We report here the preliminary results of a retrospective mono-centric, homogeneous and continuous series, of 21 non-cemented total hip implants, implanted from January 2011 to December 2014. The mean follow-up time was 24 months. The patients were evaluated by Harris’s hip at the last follow-up. Results: The mean age of the intervention was 30 years. In our series, we observed a male predominance (60% of cases). Clinically, the Harris score varied significantly from 52.6 ± 11.4 pre-operatively to 85.1 ± 5.1 during the last follow-up visit. Among the items in the score, pain was the parameter that showed the greatest improvement. Thigh pain was observed in only one patient operated on the two sides. At the level of radiology, the femoral implant showed great stability. Bone resorption was suspected in 14 cases (66.66%), and confirmed in 4 cases (19.04%) with excellent bone remodeling, illustrated by the Engh and Massin scores. A loosening and a prosthetic dislocation was observed in a patient (4.76%). Any heterotopic ossification was observed. Conclusion: Our study confirmed good clinical and radiological results of the non-cemented hip prosthesis series in young patients. The rates of aseptic loosening, acetabular edges or osteolysis are low and stable over time. 展开更多
关键词 HIP TOTAL Non-Cemented prostheses
暂未订购
Anticoagulation in Pregnant Women with Mechanical Heart Valve Prostheses: 25-Year Experience at a Tertiary Care Hospital in a Developing Country
9
作者 Ahmed Tounsi Dorra Abid +8 位作者 Doulira Louati Souad Mallek Malek Akrout Leila Abid Mohamed Abdennadher Imed Frikha Kais Chaabene Mourad Hentati Samir Kammoun 《World Journal of Cardiovascular Diseases》 2014年第6期287-293,共7页
The aim of this retrospective study was to compare the different anticoagulation regimens used in pregnant women with prosthetic heart valves. We reviewed 86 pregnancies in 57 women from 1987 to 2011. The patients wer... The aim of this retrospective study was to compare the different anticoagulation regimens used in pregnant women with prosthetic heart valves. We reviewed 86 pregnancies in 57 women from 1987 to 2011. The patients were divided into two groups: group A (39 pregnancies) had oral acenocoumarol throughout pregnancy;and in group B (47 pregnancies), acenocoumarol was replaced by subcutaneous heparin during the first trimester. Both groups received heparin at the time of delivery. The valves replaced were mitral (59.65%), aortic (12.28%), or both (28.07%). 74 pregnancies (86.04%) resulted in live births, 9 (10.46%) had stillbirths, 1 (1.16%) had spontaneous abortion and 2 (2.32%) underwent therapeutic abortions. The live birth rate was higher in women on heparin (87.23%) compared with those on acenocoumarol (84.61%). No malformations appeared in the 74 newborns, except for one case of hydrocephalus. There was one maternal death due to acute mitral valvular thrombosis while on heparin in the first trimester. Hemorrhagic complications occurred in 13 patients in the postpartum period, 4 of whom required transfusion. No anticoagulant regimen can be said to be entirely safe for use during pregnancy as there is a degree of risk with each regimen. Heparin does not offer a clear advantage over oral anticoagulation in the pregnancy outcome. 展开更多
关键词 ANTICOAGULATION Pregnancy Mechanical Heart Valve prostheses MATERNAL COMPLICATIONS HEPARIN ACENOCOUMAROL
暂未订购
Iatrogenic Oesophageal Perforations in Neoplastic Lesions: Management with Covered Self-Expanding Prostheses
10
作者 Mario Anselmi Mendez Ana MarÍA Gemmato Pascazio +1 位作者 Maximiliano Figueroa Silva Julio Salgado OyarzÚN 《Open Journal of Gastroenterology》 2021年第6期89-104,共16页
<span><span style="white-space:nowrap;font-family:Verdana;"><strong>Background:</strong></span><strong><span style="font-family:Verdana;"></span><... <span><span style="white-space:nowrap;font-family:Verdana;"><strong>Background:</strong></span><strong><span style="font-family:Verdana;"></span></strong></span><span>Perforation of the oesophagus is a serious condition. Most of them are iatrogenic and are associated with significant morbidity and mortality, especially with late diagnosis. </span><b><span style="font-family:Verdana;">Aim:</span></b><span style="font-family:Verdana;"> To prospectively analyse the results of the endoscopic management of iatrogenic perforations in oesophageal neoplasia, through the immediate insertion of a covered self-expanding prosthesis (CSES). </span><b><span style="font-family:Verdana;">Materials and Methods:</span></b><span style="font-family:Verdana;"> Between 01.01.2006 and 12.30.2016, a series of 19 consecutive patients attended the Teaching Unit of Endoscopic Surgery of the Regional de Concepción Hospital, Chile, with the diagnosis of oesophageal neoplasia confirmed by biopsy were prospectively studied. All were subjected to a prior evaluation by the oncology team and subsequently referred for endoscopic palliative management of dysphagia. The average age was 77 ± 9.3 years, 8 (42.1%) were female and 11 (57.9%) were male. In 17 patients (89.5%) the stenosis compromised the oesophagus, in 2 (10.5%) the gastro-oesophageal junction, 16 had a squamous carcinoma (84.2%) and 3 an adenocarcinoma (15.8%). </span><b><span style="font-family:Verdana;">Results: </span></b><span style="font-family:Verdana;">Perforation was diagnosed during the procedure in 18 patients (94.7%) and in 1 (5.3%) 22 hours later. Follow-up was done for a minimum of 90 days or until death. The prostheses were inserted successfully in all cases. The immediate evolution was satisfactory in 12 patients (63.2%). In the rest (36.8%), 18 complications appeared. The most frequent were retrosternal pain, subcutaneous emphysema and fever. The early evolution was satisfactory in 12/19 cases (63.2%). Complication was evidenced in 7 (36.8%), the most frequent was retrosternal pain (36.8%). Fever occurred in 3 (15.8%), pleural effusion in 3 (15.8%) and mediastinitis in 2 of these. The prosthesis was kept in situ as a definitive palliation method for neoplas</span><span><span style="font-family:Verdana;">tic dysphagia. In 10 of the 18 cases that survived more than a month, there were late complications (55.6%), none of them associated with the perforation itself. The only death (5.3%) was due to an oesophagus-pleural fistula, associated with an early prosthetic migration. Recovery of the oral intake occurred, on average, at 3.7 days. The hospital stay averaged 9.6 days. </span><b><span style="font-family:Verdana;">Conclusion: </span></b><span style="font-family:Verdana;">The use of CSES for the treatment of iatrogenic oesophageal perforations in the context of neoplasia, is a safe and effective method, with low morbidity, adequate recovery of the oral intake and prompt discharge from hospital.</span></span> 展开更多
关键词 Iatrogenic Oesophageal Perforations Self-Expanding prostheses Oesophageal Cancer
暂未订购
Testicular prostheses-impact on quality of life and sexual function
11
作者 Ana Sofia Araujo Sara Anacleto +4 位作者 Ricardo Rodrigues Catarina Tinoco Andreia Cardoso Carlos Oliveira Ricardo Leao 《Asian Journal of Andrology》 SCIE CAS CSCD 2024年第2期160-164,共5页
Orchiectomy is the recommended treatment for many testicular conditions.However,testicular prosthesis placement is not always performed for different reasons.In this study,we aimed to evaluate patients'opinions an... Orchiectomy is the recommended treatment for many testicular conditions.However,testicular prosthesis placement is not always performed for different reasons.In this study,we aimed to evaluate patients'opinions and the impact on sexual function and quality of life.This retrospective observational single-center study included patients who underwent orchiectomy between January 2014 and December 2020 at the Department of Urology,Braga's Hospital(Braga,Portugal),where testicular implants were always available and the decision to undergo the procedure was made fully independent of cost.Patients completed four questionnaires that assessed demographic data,satisfaction,self-esteem,and sexual function.Of the 96 patients who underwent orchidectomy,59 replied to the questionnaires,and of these patients,86.4%decided to undergo silicone-based testicular prostheses implantation.The remaining 13.6%refused the implant based on concerns about complications(37.5%),because they felt that it was unnecessary(37.5%),or because it was not offered by the doctor(25.0%).Overall,96.1%of these patients were satisfied with the implant;however,25.5%classified it as"too firm".No statistically significant differences were found in sexual function(all P>0.05).However,it can be observed that there are more patients with prostheses presenting normal sexual activity compared to patients without prostheses(74.0%vs 50.0%),and none of them reported severe erectile dysfunction(0 vs 16.7%).Regarding self-esteem,both patients with and without prostheses present very similar average scores with no statistically significant differences.The present study highlights the highest level of satisfaction among patients who received testicular prostheses.Testicular prostheses implantation is a safe procedure that does not hamper sexual function after orchiectomy. 展开更多
关键词 ORCHIECTOMY patient satisfaction quality of life sexual dysfunction sexual health testicular prostheses
原文传递
Influence of Ni and Cr Content on Corrosion Resistance of Ni-Cr-Mo Alloys for Fixed Dental Prostheses in 0.05% NaF Aqueous Solution
12
作者 Nilo A. S. Sampaio José W. J. Silva +3 位作者 Heloisa A. Acciari Roberto Z. Nakazato Eduardo N. Codaro Hamilton de Felipe 《Materials Sciences and Applications》 2010年第6期369-372,共4页
The Ni-Cr-Mo alloys have been used as dental prostheses because they own a good mechanical strength, high corrosion resistance and even to be economically viable. These alloys corrosion protection against in salt solu... The Ni-Cr-Mo alloys have been used as dental prostheses because they own a good mechanical strength, high corrosion resistance and even to be economically viable. These alloys corrosion protection against in salt solutions typical of physiological media is due to passivation phenomenon with an oxide surface layer formation, mainly chromium oxides. This protective film, subjected to a mechanical stress in a corrosive environment, can partially dissolve by releasing ions, which have deleterious effects in a human body. Fluoride ions, existing in hygiene products, change the buccal environment and their presence may enable a localized corrosion process initiation. The aim of this work has been to investigate the chemical composition influence of three alloys in corrosion resistance to: A (Ni-73% Cr-14% Mo-8.5% Be-1.8% Al-1.8%), B (Ni-61% Cr-25% Mo-10.5% Si-1.5%) and C (Ni-65% Cr-22.5% Mo-9.5%) in media containing fluorides that simulate mouthwashes solution. The study has been done in a 0.05% NaF solution, pH 6, at 37°C using electrochemical techniques. The alloy with the highest nickel and the lowest chromium content is not passive in the middle studied, showing a continuous increase in current density with the potential increasing, while the other alloys show passivation range of 600 mV and passive current density of about 10-6 A/cm2. 展开更多
关键词 NI-CR-MO ALLOYS DENTAL prostheses Corrosion
暂未订购
Visual prostheses, optogenetics, stem cell and gene therapies: splitting the cake
13
作者 Alejandro Barriga-Rivera Gregg J.Suaning 《Neural Regeneration Research》 SCIE CAS CSCD 2018年第5期805-806,共2页
The size of the blind population in 2015 was estimated to be approximately 36 million(Bourne et al.,2017).According to the predictions by Bourne and co-workers,the number of the visually impaired is expected to reac... The size of the blind population in 2015 was estimated to be approximately 36 million(Bourne et al.,2017).According to the predictions by Bourne and co-workers,the number of the visually impaired is expected to reach nearly 100 million by 2050. 展开更多
关键词 stem cell and gene therapies Visual prostheses OPTOGENETICS splitting the cake
暂未订购
Implant-Supported Full Fixed Prostheses with a Removable Oro-Nasal Obturator for the Edentulous Maxilla with Palatal Fistula due to Surgical Procedures for Oral Cancer
14
作者 Akifumi Enomoto Takeshi Shimoide +4 位作者 Eri Morikage Kazuhide Matsunaga Takao Mukai Takayuki Uchihashi Suguru Hamada 《Surgical Science》 2016年第10期443-452,共10页
Open oro-nasal defects resulting after oral tumor resection need structural and functional rehabilitation using dental prostheses. Conventional removable prostheses have usually been indicated and performed for prosth... Open oro-nasal defects resulting after oral tumor resection need structural and functional rehabilitation using dental prostheses. Conventional removable prostheses have usually been indicated and performed for prosthodontics. When the patient has an edentulous maxilla, the unfavorable stability of the prosthesis will cause dysfunction of mastication and pronunciation. To achieve improvement of the impaired functional situation, implant-supported full fixed prostheses (IPSPs) for the edentulous maxilla with a removable obturator offer a reasonable solution. We present herein the case of a 70-year-old Japanese man who has presented with oro-nasal defect due to surgical procedures for oral cancer. He was treated with implant-supported full fixed prostheses in a conventional two-step procedure. After prosthesis treatment, a palatal obturator was set. The patient has shown no clinical or radiological evidence of failure as of 24 months after the end of treatment. Functional evaluation of mastication and pronunciation showed dramatic improvements. For a patient with an edentulous maxilla and palatal fistula, full-arch fixed prostheses supported by a combination of axially and non-axially positioned implants and a removable oro-nasal obturator, using the anterior alveolar bone, without bone transplantation or maxillary sinus elevation, could offer an effective, minimally invasive treatment alternative. 展开更多
关键词 Implant-Supported Full Fixed prostheses Oro-Nasal Obturator Oral Tumor
暂未订购
Towards Long-Life Replacement Joint Prostheses - A Surface Engineering Approach
15
作者 HanshanDong 《材料热处理学报》 EI CAS CSCD 北大核心 2004年第05B期1287-1290,共4页
How to improve the wear resistance of bearing surfaces, hereby achieving long life of orthopaedic joint prostheses has long been a technical challenge with much fundamental interest and social and economic impacts. Su... How to improve the wear resistance of bearing surfaces, hereby achieving long life of orthopaedic joint prostheses has long been a technical challenge with much fundamental interest and social and economic impacts. Surface engineering has been emerging as one of the most promising technologies to improve the tribological properties of biomedical materials. A current area of research within the Birmingham Surface Engineering Group has been directed at developing novel surface engineering technologies for biomedical materials towards long-life joint prostheses. Following a brief introduction, the author reports their recent progress in the surface engineering of biomedical materials particular for joint prosthesis. The potential of these innovative surface engineering technologies in enhancing the performance of oral and maxillofacial implants and surgical devices is also discussed. 展开更多
关键词 表面工程 生物材料 等离子合金 离子束 陶瓷转化
在线阅读 下载PDF
Myoelectric prostheses for special stumps
16
作者 Luo Yong-Zhao(Shanghai Institute of Physiology Chinese Academy of Sciences,Shanghai 200031,PR.China) 《Chinese Journal of Biomedical Engineering(English Edition)》 1999年第3期4-4,共1页
关键词 Myoelectric prostheses for special stumps
暂未订购
Comparison between MatriX and mAXIS titanium prosthesis in stapedotomy:prospective study and review of the literature
17
作者 Angelo Immordino Pollarolo Marco +4 位作者 Francesco Lorusso Federico Sireci Palmira Immordino Salvatore Gallina Francesco Dispenza 《Journal of Otology》 2025年第2期93-102,共10页
Background:Stapes prostheses play a crucial role in improving auditory performance and facilitating the patient's reintegration into social life.However,determining the ideal characteristics of a prosthesis and id... Background:Stapes prostheses play a crucial role in improving auditory performance and facilitating the patient's reintegration into social life.However,determining the ideal characteristics of a prosthesis and identifying the best commercially available option remain challenging.This study aims to compare the outcomes of two different types of prostheses:the MatriX Stapes Prosthesis and the new mAXIS Stapes Prosthesis.Methods:A prospective study was conducted on patients diagnosed with suspected otosclerosis who underwent stapedotomy,receiving either the MatriX or m AXIS prosthesis randomly during surgery.Postoperative follow-ups were conducted for at least one year.Audiometric evaluations were analyzed using statistical tests.Additionally,a systematic review was conducted according to the Preferred Reporting Items for Systematic Reviews and Metaanalyses(PRISMA)statement.Results:The prospective study included 84 patients,divided into two groups(G1:MatriX,G2:mAXIS).The auditory results were satisfactory for both prostheses,demonstrating their effectiveness in improving hearing thresholds.We observed a gain for air conduction threshold of 26.2 dB vs 21.2 dB with an ABG closure of 20.7 dB vs and 21.2 dB in G1 and G2 respectively.The literature review encompassed 15studies,revealing overall positive outcomes with different prosthetic materials.Conclusions:The study revealed effective auditory improvement with both prostheses,yet no statistically significant differences in air-bone gap closure or average hearing gain.Titanium emerged as the preferred material due to its biocompatibility,lightweight nature,and stability under magnetic resonance imaging.The mAXIS prosthesis is introduced as a cost-effective alternative with favorable intraoperative features. 展开更多
关键词 STAPEDOTOMY stapes surgery stapes prostheses systematic review
暂未订购
Mobi-C人工颈椎间盘置换术对颈椎曲度的影响 被引量:5
18
作者 鲍达 陈兴 +2 位作者 李力韬 于龙 马远征 《中国骨与关节损伤杂志》 2018年第7期673-675,共3页
目的探讨采用Mobi-C人工颈椎间盘置换术治疗颈椎退行性疾病术后对患者颈椎曲度的影响。方法回顾性分析自2009-01—2010-12经前路行椎间盘切除减压、Mobi-C人工颈椎间盘置换术治疗的25例颈椎退行性疾病,并进行了5年以上的随访观察。比较... 目的探讨采用Mobi-C人工颈椎间盘置换术治疗颈椎退行性疾病术后对患者颈椎曲度的影响。方法回顾性分析自2009-01—2010-12经前路行椎间盘切除减压、Mobi-C人工颈椎间盘置换术治疗的25例颈椎退行性疾病,并进行了5年以上的随访观察。比较术前、术后即刻、末次随访时置换节段脊柱功能单位(FSU)曲度。结果 25例均获得随访,随访时间平均62.5(60~65)个月。术前FSU曲度为(0.28±4.69)°,术后即刻为(2.09±4.15)°,末次随访时为(1.97±4.10)°;手术前后FSU曲度差异有统计学意义(F=3.187,P=0.003),且术后即刻FSU曲度较术前明显改善(P=0.003),但末次随访时FSU曲度与术后即刻比较差异无统计学意义(P=0.044)。术前2例FSU后凸>10°(即FSU曲度<-10°),术后置换节段仍存在后凸畸形。结论采用Mobi-C假体行人工椎间盘置换术治疗颈椎退行性疾病可以部分矫正置换节段的后凸畸形,术后置换节段曲度维持良好,但对于术前FSU后凸>10°的颈椎退行性疾病患者不建议行该手术。 展开更多
关键词 颈椎退行性疾病 人工椎间盘置换术 mobi-c假体 脊柱后凸畸形
原文传递
Mobi-C人工颈椎间盘临床应用初步报告 被引量:5
19
作者 鲍达 马远征 +3 位作者 陈兴 李宏伟 胡明 高天君 《中国修复重建外科杂志》 CAS CSCD 北大核心 2011年第1期70-73,共4页
目的探讨采用Mobi-C人工颈椎间盘假体在颈椎前路椎间盘切除减压、人工椎间盘置换术(artificial disc replacement,ADR)中的临床应用价值。方法 2009年1月-6月,收治符合颈椎间盘置换指征的颈椎退行性疾病患者20例。其中男8例,女12例;年... 目的探讨采用Mobi-C人工颈椎间盘假体在颈椎前路椎间盘切除减压、人工椎间盘置换术(artificial disc replacement,ADR)中的临床应用价值。方法 2009年1月-6月,收治符合颈椎间盘置换指征的颈椎退行性疾病患者20例。其中男8例,女12例;年龄29~54岁,平均45.2岁。颈椎间盘突出症13例,神经根型颈椎病7例。病程4d~5年,平均1.2年。病变节段:C3、41例,C4、52例,C5、67例,C6、75例,C4、5合并C5、62例,C5、6合并C6、73例。术前常规行颈椎正侧位、动力位X线片及MRI检查。均行经前路椎间盘切除减压、Mobi-C人工颈椎间盘假体ADR,共植入Mobi-C人工颈椎间盘假体25枚。所有患者术后定期摄X线片测量置换节段活动度(range of motion,ROM);采用北京大学第三医院40分(COA)评分系统评价患者术前及末次随访时的颈脊髓功能;采用颈椎残障功能量表(NDI)评分及疼痛视觉模拟评分(VAS)评价患者生活质量。结果所有患者术后切口均Ⅰ期愈合,术中、术后未出现手术相关并发症。20例均获随访,随访时间14~18个月,平均16.5个月。术前及末次随访时置换节段ROM比较差异无统计学意义(t=0.808,P=0.440)。随访期内未见异位骨化。术前及末次随访时COA评分分别为(32.10±2.96)分和(38.20±1.14)分,差异有统计学意义(t=9.278,P=0.000);末次随访时改善率为77.2%±5.4%。术前及末次随访时VAS评分分别为(5.10±1.29)分和(3.20±1.23)分,差异有统计学意义(t=10.585,P=0.000);NDI评分分别为(39.20±3.80)分和(29.40±4.55)分,差异有统计学意义(t=16.039,P=0.000)。结论在合理选择适应证的前提下,采用Mobi-C人工颈椎间盘假体行ADR治疗退行性颈椎疾患,近期临床疗效满意。 展开更多
关键词 人工椎间盘置换术 mobi-c人工颈椎间假体 颈椎间盘突出症 神经根型颈椎病
原文传递
单节段Mobi-C人工间盘置换术后颈椎活动度的变化 被引量:4
20
作者 田天 谭荣 +3 位作者 陈晓明 张晔 崔凯 刘涛 《颈腰痛杂志》 2017年第1期18-21,共4页
目的观察单节段Mobi-C人工间盘置换术后颈椎曲度、活动度的变化。方法 2012-07-2015-01我院行22例单节段Mobi-C人工间盘置换术,年龄27-55岁,平均42.3岁,置换节段C_(4-5)5例,C_(5-6)10例,C_(6-7)7例。测量术前及末次随访时颈椎曲度和活... 目的观察单节段Mobi-C人工间盘置换术后颈椎曲度、活动度的变化。方法 2012-07-2015-01我院行22例单节段Mobi-C人工间盘置换术,年龄27-55岁,平均42.3岁,置换节段C_(4-5)5例,C_(5-6)10例,C_(6-7)7例。测量术前及末次随访时颈椎曲度和活动度。结果随访时间3-26个月,平均9.3个月。术后颈椎整体曲度和置换节段局部曲度均较术前改善:颈椎整体曲度术前(0.91±9.77)°,术后(4.91±10.67)°,脊柱功能单位角术前(0.23±5.17)°,术后(5.73±4.45)°,置换节段前柱高度术前(34.07±3.29)mm,术后(35.73±3.46)mm,差异均具有统计学意义(P<0.05)。末次随访时,颈椎整体活动度、置换节段活动度、相邻节段活动度较术前差异均无统计学意义。结论Mobi-C置换术后颈椎整体曲度和置换节段局部曲度均较术前改善,保留了置换节段活动度,相邻节段活动度无明显增大。 展开更多
关键词 人工椎间盘 mobi-c 活动度
暂未订购
上一页 1 2 45 下一页 到第
使用帮助 返回顶部