Nitrogen content is an important parameter for petroleum refining processes.The combined use of mid-infrared attenuated total reflection spectroscopy and multivariate calibration allows accurate determination of nitro...Nitrogen content is an important parameter for petroleum refining processes.The combined use of mid-infrared attenuated total reflection spectroscopy and multivariate calibration allows accurate determination of nitrogen content in petroleum and its products.The calibration models of nitrogen content in crude oils have been established by partial least squares(PLS)method.The results predicted by this method were very close to those determined by standard methods.Compared with standard methods,this method is provided with advantages such as high-speed,simplicity and good-repeat-ability without any needs for pretreatment.展开更多
Noninvasive,glucose-monitoring technologies using infrared spectroscopy that have been studied typically require a calibration process that involves blood collection,which renders the methods somewhat invasive.We deve...Noninvasive,glucose-monitoring technologies using infrared spectroscopy that have been studied typically require a calibration process that involves blood collection,which renders the methods somewhat invasive.We develop a truly noninvasive,glucose-monitoring technique using midinfrared spectroscopy that does not require blood collection for calibration by applying domain adaptation(DA)using deep neural networks to train a model that associates blood glucose concentration with mid-infrared spectral data without requiring a training dataset labeled with invasive blood sample measurements.For realizing DA,the distribution of unlabeled spectral data for calibration is considered through adversarial update during training networks for regression to blood glucose concentration.This calibration improved the correlation coeffcient between the true blood glucose concentrations and predicted blood glucose concentrations from 0.38 to 0.47.The result indicates that this calibration technique improves prediction accuracy for mid-infrared glucose measurements without any invasively acquired data.展开更多
This paper aims at testing oxygen and benzene contents in gasoline by mid-infrared spectroscopy.The experimental results prove that infrared spectroscopy(IR)is reliable.Compared with gas chromatography(GC)technology,t...This paper aims at testing oxygen and benzene contents in gasoline by mid-infrared spectroscopy.The experimental results prove that infrared spectroscopy(IR)is reliable.Compared with gas chromatography(GC)technology,this paper draws a conclusion that IR has several advantages,including rapid analysis,excellent repeatability and low analysis cost.展开更多
In order to monitor malt quality in the malting industry, despite yearly variations in the barley quality, 394 barley samples were analysed using conventional (moisture, protein and B-glucan content) and mid-infrare...In order to monitor malt quality in the malting industry, despite yearly variations in the barley quality, 394 barley samples were analysed using conventional (moisture, protein and B-glucan content) and mid-infrared Fourier transform spectroscopy FT-IR. The experimental dataset included barley from three harvest years, two barley species, 77 barley varieties, and two-row and six-row barley, from 16 cultivation sites. For each sample, the malt quality indices were also assessed according to European Brewing Convention (EBC) standards. Principal component analysis (PCA) was carried out on mean-centred, normalized and derivative spectra using 200/cm width spectral bands. The most informative spectral bands were observed in the 800-1,000/cm and 1,000-1,200/cm ranges. PCA revealed that barley harvested in 2010 and in 2011 had bands that were very close together, while 2009 harvest clearly displayed a difference in its quality. PCA made it possible to distinguish two species and confirmed that two-row winter barley quality was closer to two-row spring barley quality than to six-row winter barley. Results indicate that mid-infrared spectrometry (MIR) could be a very useful and rapid analytical tool to assess barley qualitative quality.展开更多
Cell wall composition in monocotyledonous grasses has been identified as a key area of research for developing better feedstocks for forage and biofuel production.Setaria viridis and its close domesticated relative Se...Cell wall composition in monocotyledonous grasses has been identified as a key area of research for developing better feedstocks for forage and biofuel production.Setaria viridis and its close domesticated relative Setaria italica have been chosen as suitable monocotyledonous models for plants possessing the C4 pathway of photosynthesis including sorghum,maize,sugarcane,switchgrass and Miscanthus×giganteus.Accurate partial least squares regression(PLSR)models to predict S.italica stem composition have been generated,based upon Fourier transform mid-infrared(FTIR)spectra and calibrated with wet chemistry determinations of ground S.italica stem material measured using a modified version of the US National Renewable Energy Laboratory(NREL)acid hydrolysis protocol.The models facilitated a high-throughput screening analysis for glucan,xylan,Klason lignin and acid soluble lignin(ASL)in a collection of 183 natural S.italica variants and clustered them into classes,some possessing unique chemotypes.The predictive models provide a highly efficient screening tool for large scale breeding programs aimed at identifying lines or mutants possessing unique cell wall chemotypes.Genes encoding key catalytic enzymes of the lignin biosynthesis pathway exhibit a high level of conservation with matching expression profiles,measured by RT-q PCR,among accessions of S.italica,which closely mirror profiles observed in the different developmental regions of an elongating internode of S.viridis by RNASeq.展开更多
A compact prototype based on mid-infrared wavelength modulation spectroscopy(WMS)is developed for the simul-taneous monitoring of NO,NO2,and NH3 in the urban area.Three quantum cascade lasers(QCLs)with central fre...A compact prototype based on mid-infrared wavelength modulation spectroscopy(WMS)is developed for the simul-taneous monitoring of NO,NO2,and NH3 in the urban area.Three quantum cascade lasers(QCLs)with central frequencies around 1900.0 cm^-1,1600.0 cm^-1,and 1103.4 cm^-1are used for NO,NO2,and NH3detections,respectively,by timedivision multiplex.An open-path multi-pass cell of 60-m optical path length is applied to the instrument for high sensitivity and reducing the response time to less than 1 s.The prototype achieves a sub-ppb detection limit for all the three target gases with an average time of about 100 s.The instrument is installed in the Jiangsu environmental monitoring center to conduct performance tests on ambient air.Continuous 24-hour measurements show good agreement with the results of a reference instrument based on the chemiluminescence technique.展开更多
A dual-gas sensor system is developed for CO and CO_2 detection using a single broadband light source, pyroelectric detectors and time-division multiplexing(TDM) technique. A stepper motor based rotating system and a ...A dual-gas sensor system is developed for CO and CO_2 detection using a single broadband light source, pyroelectric detectors and time-division multiplexing(TDM) technique. A stepper motor based rotating system and a single-reflection spherical optical mirror are designed and adopted for realizing and enhancing dual-gas detection. Detailed measurements under static detection mode(without rotation) and dynamic mode(with rotation) are performed to study the performance of the sensor system for the two gas samples. The detection period is 7.9 s in one round of detection by scanning the two detectors. Based on an Allan deviation analysis, the 1σ detection limits under static operation are 3.0 parts per million(ppm) in volume and 2.6 ppm for CO and CO_2, respectively, and those under dynamic operation are 9.4 ppm and 10.8 ppm for CO and CO_2, respectively. The reported sensor has potential applications in various fields requiring CO and CO_2 detection such as in the coal mine.展开更多
Rapid and sensitive recognition of herbal pieces according to different concocted processing is crucial to quality control and pharmaceutical effect. Near-infrared (NIR) and mid-infrared (MIR) technology combined ...Rapid and sensitive recognition of herbal pieces according to different concocted processing is crucial to quality control and pharmaceutical effect. Near-infrared (NIR) and mid-infrared (MIR) technology combined with supervised pattern recognition based on partial least-squares discriminant analysis (PLSDA) was attempted to classify and recognize six different concocted processing pieces of 600 Areca catechu L. samples and the influence of fingerprint information preprocessing methods on recognition performance was also investigated in this work. Recognition rates of 99.24%, 100% and 99.49% for original fingerprint, multiple scatter correct (MSC) fingerprint and second derivative (2nd derivative) fingerprint of NIR spectra were achieved by PLSDA models, respectively. Meanwhile, a perfect recognition rate of 100% was obtained for the above three fingerprint models of MIR spectra. In conclusion, PLSDA can rapidly and effectively extract otherness of fingerprint information from NIR and MIR spectra to identify different concocted herbal pieces ofA. catechu.展开更多
Mid-infrared(MIR)-polarized thermal emission has broad applications in areas such as molecular sensing,information encryption,target detection,and optical communication.However,it is difficult for objects in nature to...Mid-infrared(MIR)-polarized thermal emission has broad applications in areas such as molecular sensing,information encryption,target detection,and optical communication.However,it is difficult for objects in nature to produce polarized thermal emission.Moreover,simultaneously generating and modulating broadband MIR thermal emission with both circular and linear polarization is even more difficult.We present a chiral plasmonic metasurface emitter(CPME)composed of asymmetric L-shaped and I-shaped antennas.The CPME consists of In_(3)SbTe_(2)(IST)phase-change material(PCM)antennas,an Al_(2)O_(3) dielectric layer,and an Au substrate.It is demonstrated that the CPME can selectively emit polarized light with different polarization states.Numerical simulations show that the CPME can achieve full Stokes parameter control of MIR thermal emission.By changing the state of the PCM IST,the spectral emissivity of 0 deg,45 deg,90 deg,and 135 deg linearly polarized(LP)lights and left-handed/right-handed circularly polarized(LCP/RCP)lights can be adjusted.In the crystalline state,the CPME exhibits the total degree of polarization(DoP)greater than 0.5 in the wavelength range of 3.4 to 5.3μm,the degree of linear polarization(DoLP)greater than 0.4 in the range of 3.0 to 5.1μm,and the degree of circular polarization(DoCP)greater than 0.4 in the range of 4.5 to 5.6μm.The physical mechanism of polarized emission has been investigated fully based on the near-field intensity distribution and power loss distribution.Finally,the potential applications of the designed CPME in infrared polarization detection and antidetection are verified through numerical calculations.展开更多
Electro-Optic Sampling(EOS)detection technique has been widely used in terahertz science and tech⁃nology,and it also can measure the field time waveform of the few-cycle laser pulse.Its frequency response and band lim...Electro-Optic Sampling(EOS)detection technique has been widely used in terahertz science and tech⁃nology,and it also can measure the field time waveform of the few-cycle laser pulse.Its frequency response and band limitation are determined directly by the electro-optic crystal and duration of the probe laser pulse.Here,we investigate the performance of the EOS with thin GaSe crystal in the measurement of the mid-infrared few-cycle la⁃ser pulse.The shift of the central frequency and change of the bandwidth induced by the EOS detection are calcu⁃lated,and then the pulse distortions induced in this detection process are discussed.It is found that this technique produces a red-shift of the central frequency and narrowing of the bandwidth.These changings decrease when the laser wavelength increases from 2μm to 10μm.This work can help to estimate the performance of the EOS de⁃tection technique in the mid-infrared band and offer a reference for the related experiment as well.展开更多
Optical frequency combbased Fourier transform spectroscopy has the features of broad spectral bandwidth,high sensitivity,andmultiplexed trace gas detection,which has valuable application potential in the fields of pre...Optical frequency combbased Fourier transform spectroscopy has the features of broad spectral bandwidth,high sensitivity,andmultiplexed trace gas detection,which has valuable application potential in the fields of precision spectroscopy and trace gas detection.Here,we report the development of a mid-infrared Fourier transform spectrometer based on an optical frequency comb combined with a Herriott-type multipass cell.Using this instrument,the broadband absorption spectra of several important molecules,including methane,acetylene,water molecules and nitrous oxide,are measured by near real-time data acquisition in the 2800-3500 cm^(-1)spectral region.The achieved minimum detectable absorption of the instrument is 4.4×10^(-8)cm^(-1)·Hz^(-1/2)per spectral element.Broadband spectra of H_(2)0 are fited using the Voigt profile multispectral fitting technique and the consistency of the concentration inversion is 1%.Our system also enables precise spectroscopic measurements,and it allows the determination of the spectral line positions and upper state constants of N_(2)O in the(0002)-(1000)band,with results in good agreement with those reported by Toth[Appl.Opt.30,5289(1991)].展开更多
Mid-infrared(MIR)spectral imaging enables precise target identification and analysis by capturing rich chemical fingerprints,which calls for high-sensitivity broadband MIR imagers at room temperature.Here,we devise an...Mid-infrared(MIR)spectral imaging enables precise target identification and analysis by capturing rich chemical fingerprints,which calls for high-sensitivity broadband MIR imagers at room temperature.Here,we devise and implement a continuous-wave pumping MIR upconversion imaging system based on externalcavity enhancement,which favors a large field of view,a low cavity loss,and a high spectral resolution.The involved optical cavity is constructed in an integrated fashion by utilizing one crystal facet as a cavity mirror,which allows a 43-fold power enhancement for the single-longitudinal-mode pump at 1064 nm.In combination with the chirped-poling crystal design,high-fidelity and wide-field spectral imaging mapping is permitted to facilitate an acceptance angle of up to 28.5 deg over a spectral coverage of 2.5 to 5μm.Moreover,a thermal locking approach is used to stabilize the cavity at high-power operation,eliminating active feedback and ensuring long-term stability.A proof-of-principle demonstration is presented to showcase real-time observation of CO_(2)gas injection dynamics.The implemented MIR upconversion imager features wide-field operation,high detection sensitivity,and compact footprint,which would benefit subsequent applications,including environment monitoring,gas leakage inspection,and medical diagnostics.展开更多
Tunable mid-infrared lasers are essential for optical sensing and imaging.Existing technologies,however,face challenges in simultaneously achieving broadband spectral tunability and ultra-rapid scan rates,limiting the...Tunable mid-infrared lasers are essential for optical sensing and imaging.Existing technologies,however,face challenges in simultaneously achieving broadband spectral tunability and ultra-rapid scan rates,limiting their utility in dynamic scenarios such as real-time characterization of multiple molecular absorption bands.We present a high-speed approach for broadband wavelength sweeping in the mid-infrared region,leveraging spectral focusing via difference-frequency generation between a chirped fiber laser and an asynchronous,frequency-modulated electro-optic comb.This method enables pulse-to-pulse spectral tuning at a speed of 5.6 THz∕μs with 380 elements.Applied to spectroscopic sensing,our technique achieves broad spectral coverage(2600 to 3780 cm−1)with moderate spectral resolution(8 cm−1)and rapid acquisition time(-6.3μs).Notably,the controllable electro-optic comb facilitates high scan rates of up to 2 Mscans∕s across the full spectral range(corresponding to a speed of 60 THz∕μs),with trade-offs in number of elements(-30)and spectral point spacing or resolution(33 cm−1).Nevertheless,these capabilities make our platform highly promising for applications such as flow cytometry,chemical reaction monitoring,and mid-infrared ranging and imaging.展开更多
In this paper,a tunable metamaterial absorber based on a Dirac semimetal is proposed.It consists of three different structures,from top to bottom,namely a double semicircular Dirac semimetal resonator,a silicon dioxid...In this paper,a tunable metamaterial absorber based on a Dirac semimetal is proposed.It consists of three different structures,from top to bottom,namely a double semicircular Dirac semimetal resonator,a silicon dioxide substrate and a continuous vanadium dioxide(VO_(2))reflector layer.When the Fermi energy level of the Dirac semimetal is 10 meV,the absorber absorbs more than 90%in the 39.06-84.76 THz range.Firstly,taking advantage of the tunability of the conductivity of the Dirac semimetal,dynamic tuning of the absorption frequency can be achieved by changing the Fermi energy level of the Dirac semimetal without the need to optimise the geometry and remanufacture the structure.Secondly,the structure has been improved by the addition of the phase change material VO_(2),resulting in a much higher absorption performance of the absorber.Since VO_(2)is a temperature-sensitive metal oxide with an insulating phase below the phase transition temperature(about 68℃)and a metallic phase above the phase transition temperature,this paper also analyses the effect of VO_(2)on the absorptive performance at different temperatures,with the aim of further improving absorber performance.展开更多
The Savitzky-Golay(SG)filter,which employs polynomial least-squares approximations to smooth data and estimate derivatives,is widely used for processing noisy data.However,noise suppression by the SG filter is recogni...The Savitzky-Golay(SG)filter,which employs polynomial least-squares approximations to smooth data and estimate derivatives,is widely used for processing noisy data.However,noise suppression by the SG filter is recognized to be limited at data boundaries and high frequencies,which can significantly reduce the signal-to-noise ratio(SNR).To solve this problem,a novel method synergistically integrating Principal Component Analysis(PCA)with SG filtering is proposed in this paper.This approach avoids the is-sue of excessive smoothing associated with larger window sizes.The proposed PCA-SG filtering algorithm was applied to a CO gas sensing system based on Cavity Ring-Down Spectroscopy(CRDS).The perform-ance of the PCA-SG filtering algorithm is demonstrated through comparison with Moving Average Filtering(MAF),Wavelet Transformation(WT),Kalman Filtering(KF),and the SG filter.The results demonstrate that the proposed algorithm exhibits superior noise reduction capabilities compared to the other algorithms evaluated.The SNR of the ring-down signal was improved from 11.8612 dB to 29.0913 dB,and the stand-ard deviation of the extracted ring-down time constant was reduced from 0.037μs to 0.018μs.These results confirm that the proposed PCA-SG filtering algorithm effectively improves the smoothness of the ring-down curve data,demonstrating its feasibility.展开更多
Exploring cost-effective and efficient catalysts for oxygen reduction reaction(ORR)poses a significant challenge,espe-cially in the pursuit of alternatives to precious metals like platinum.Significant advancements hav...Exploring cost-effective and efficient catalysts for oxygen reduction reaction(ORR)poses a significant challenge,espe-cially in the pursuit of alternatives to precious metals like platinum.Significant advancements have driven electrochem-ists to develop efficient ORR catalysts using abundant materials,particularly iron(Fe)-based,known for their exceptional performance in ORR.While the crucial function of Fe in boosting ORR catalytic activity is recognized,the connection between material attributes and catalytic performance remains enigmatic.Understanding the dynamic processes involved in oxygen electrocatalysis is paramount for designing precious-metals-free ORR electrocatalysts.Mössbauer spectroscopy stands out as a powerful technique for deciphering the structural characteristics of Fe species in catalysis,facilitating the identification of active sites and the clarification of catalytic mechanisms.By showcasing noteworthy case studies within this review,we demonstrate the application of in-situ/operando 57Fe Mössbauer spectroscopy across diverse Fe-involved materials in ORR catalysis.This sheds light on various aspects of ORR catalysis,such as identifying active sites,assessing stability,and understanding the reaction mechanism.Our inquiry drives towards the opportunities and hurdles associ-ated with Mössbauer spectroscopy,unveiling potential breakthroughs and avenues for enhancement within this pivotal research realm.展开更多
This paper describes the design and performance of the tender energy spectroscopy beamline(BL16U1),a phase Ⅱ beamline,at the Shanghai Synchrotron Radiation Facility.The beamline,based on an in-vacuum undulator source...This paper describes the design and performance of the tender energy spectroscopy beamline(BL16U1),a phase Ⅱ beamline,at the Shanghai Synchrotron Radiation Facility.The beamline,based on an in-vacuum undulator source with 26 mm period,provides an operable energy range between 2.1 keV and 16 keV,covering the K-edges of P to Rb and L3-edges of Zr to Bi.The principal optical elements of the beamline are a toroidal mirror,a liquid nitrogen-cooled double-crystal monochromator,a high-harmonic-rejection mirror,and two pairs of Kirkpatrick–Baez(KB)mirrors.Three end-stations,including non-focusing,microprobe,and sub-microprobe types,are installed on the beamline.X-ray fluorescence(XRF)and X-ray absorption spectroscopy(XAS),including X-ray absorption near-edge structure(XANES)and extended X-ray absorption fine structure(EXAFS),are performed under vacuum or He atmosphere at the non-focusing end-station(with a beam spot size of∼670μm×710μm).Using two KB mirrors systems,micro-XRF(μXRF)mapping and micro-XANES(μXANES)studies can be performed with a spot size of approximately∼3.3μm×1.3μm at the microprobe end-station and with a smaller spot size of∼0.5μm×0.25μm at the sub-microprobe end-station.The non-focusing end-station was officially opened to users in January 2024.The microprobe and sub-microprobe end-stations will be opened to users in the near future.This paper presents the characteristics,short-term technical developments,and early experimental results of this new beamline.展开更多
With the development of mid-infrared (MIR) photoelectric devices, mid-infrared spectroscopy has become one of the important methods for non-invasive detection of blood glucose. The mid-infrared region (4000 - 400 cm&l...With the development of mid-infrared (MIR) photoelectric devices, mid-infrared spectroscopy has become one of the important methods for non-invasive detection of blood glucose. The mid-infrared region (4000 - 400 cm<sup>-1</sup>) has the well-known fingerprint region (1200 - 800 cm<sup>-1</sup>) of glucose, which has clearer characteristic absorption peaks and better specificity. There is a lot of molecular information about glucose in the MIR. The non-invasive detection of blood glucose by mid-infrared spectroscopy needs to achieve certain accuracy, and the quantitative model is an important factor affecting the accuracy of glucose detection. In this paper, the samples of imitation solution containing only glucose and the samples of imitation mixed solution are taken as the research objects, and the mid-infrared spectral data of the samples are collected. The full spectrum partial least squares Regression (PLSR) model, SNV + Ctr-PLSR model, MSC + Ctr-PLSR model, and convolutional neural networks (CNN) model of 3000 - 900 cm<sup>-1</sup> band were constructed. Full spectrum PLS model and CNN model of 1200 - 900 cm<sup>-1</sup> band were constructed. The experimental results show that the optimal model of the two bands is CNN, then the correlation coefficient of prediction set (Rp) of 3000 - 900 cm<sup>-1</sup> band is 0.95, and the root mean square error of pre-diction set (RMSEP) value is 22.10. The Rp of 1200 - 900 cm<sup>-1</sup> band is 0.95, and the RMSEP value is 22.54. The research results show that CNN is a promising method, which has higher accuracy than PLSR, and is especially suitable for modeling human complex environment. In addition, the study provides a theoretical and practical basis for CNN in feature selection and model interpretation.展开更多
The formation of copper deposits is closely related to hydrothermal processes.Understanding the migration of copper in hydrothermal fluids aids in reconstructing mineralization processes and deciphering deposit genesi...The formation of copper deposits is closely related to hydrothermal processes.Understanding the migration of copper in hydrothermal fluids aids in reconstructing mineralization processes and deciphering deposit genesis.Copper primarily exists as Cu^(+)and Cu^(2+)in hydrothermal solutions,with redox conditions governing their interconversion.In chloride-rich geological fluids,Cu-Cl complexes are considered critical for copper transport.However,the specific types and valence transitions of Cu-Cl complexes under varying hydrothermal conditions remain poorly understood.This study employed in situ Raman spectroscopy to systematically analyze Cu+HCl and CuCl_(2)+K_(2)S_(2)O_(3)/H_(2) systems under saturated vapor pressure at 25-300℃,elucidating the effects of temperature,Cl^(-)concentration,and redox conditions on copper speciation.In the Cu^(+)HCl system,copper dissolved as monovalent Cu-Cl complexes.At high temperatures(>200℃),[CuCl_(2)]^(-)is the dominated species,whereas[CuCl_(3)]^(2-)becomes prevalent at lower temperatures and higher HCl concentrations.For the Cu^(2+)-Cl system,the dominant species transitioned from[Cu(H_(2)O)n]^(2+)(<50℃)to[CuCl_(4)]^(2-)(100℃)and further to[CuCl]^(+)and[CuCl_(2)]^(0) at 300℃.The introduction of reducing agents(K_(2)S_(2)O_(3)/H_(2))facilitated Cu^(2+)→Cu^(+)reduction,thereby stabilizing Cu^(+)-Cl complexes and inducing partial copper precipitation.The behavior of copper in chloriderich hydrothermal fluids observed in this study indicates that high-temperature oxidizing fluids facilitate Cu mobilization,while cooling and redox changes promote deposition and ore minerals formation.展开更多
A RadioFrequency Quadrupole(RFQ)cooler-buncher system was developed and implemented in a collinear laser spectroscopy setup.This system converts a continuous ion beam into short bunches while enhancing the beam qualit...A RadioFrequency Quadrupole(RFQ)cooler-buncher system was developed and implemented in a collinear laser spectroscopy setup.This system converts a continuous ion beam into short bunches while enhancing the beam quality and reducing the energy spread.The functionality of the RFQ cooler buncher was verified through offline tests with stable rubidium and indium beams delivered from a surface ion source and a laser ablation ion source,respectively.Bunched ion beams with a full width at half maximum of approximately 2μs in the time-of-flight spectrum were successfully achieved with a transmission efficiency exceeding 60%.The implementation of the RFQ cooler-buncher system also significantly improved the overall transmission efficiency of the collinear laser spectroscopy setup.展开更多
文摘Nitrogen content is an important parameter for petroleum refining processes.The combined use of mid-infrared attenuated total reflection spectroscopy and multivariate calibration allows accurate determination of nitrogen content in petroleum and its products.The calibration models of nitrogen content in crude oils have been established by partial least squares(PLS)method.The results predicted by this method were very close to those determined by standard methods.Compared with standard methods,this method is provided with advantages such as high-speed,simplicity and good-repeat-ability without any needs for pretreatment.
文摘Noninvasive,glucose-monitoring technologies using infrared spectroscopy that have been studied typically require a calibration process that involves blood collection,which renders the methods somewhat invasive.We develop a truly noninvasive,glucose-monitoring technique using midinfrared spectroscopy that does not require blood collection for calibration by applying domain adaptation(DA)using deep neural networks to train a model that associates blood glucose concentration with mid-infrared spectral data without requiring a training dataset labeled with invasive blood sample measurements.For realizing DA,the distribution of unlabeled spectral data for calibration is considered through adversarial update during training networks for regression to blood glucose concentration.This calibration improved the correlation coeffcient between the true blood glucose concentrations and predicted blood glucose concentrations from 0.38 to 0.47.The result indicates that this calibration technique improves prediction accuracy for mid-infrared glucose measurements without any invasively acquired data.
文摘This paper aims at testing oxygen and benzene contents in gasoline by mid-infrared spectroscopy.The experimental results prove that infrared spectroscopy(IR)is reliable.Compared with gas chromatography(GC)technology,this paper draws a conclusion that IR has several advantages,including rapid analysis,excellent repeatability and low analysis cost.
文摘In order to monitor malt quality in the malting industry, despite yearly variations in the barley quality, 394 barley samples were analysed using conventional (moisture, protein and B-glucan content) and mid-infrared Fourier transform spectroscopy FT-IR. The experimental dataset included barley from three harvest years, two barley species, 77 barley varieties, and two-row and six-row barley, from 16 cultivation sites. For each sample, the malt quality indices were also assessed according to European Brewing Convention (EBC) standards. Principal component analysis (PCA) was carried out on mean-centred, normalized and derivative spectra using 200/cm width spectral bands. The most informative spectral bands were observed in the 800-1,000/cm and 1,000-1,200/cm ranges. PCA revealed that barley harvested in 2010 and in 2011 had bands that were very close together, while 2009 harvest clearly displayed a difference in its quality. PCA made it possible to distinguish two species and confirmed that two-row winter barley quality was closer to two-row spring barley quality than to six-row winter barley. Results indicate that mid-infrared spectrometry (MIR) could be a very useful and rapid analytical tool to assess barley qualitative quality.
文摘Cell wall composition in monocotyledonous grasses has been identified as a key area of research for developing better feedstocks for forage and biofuel production.Setaria viridis and its close domesticated relative Setaria italica have been chosen as suitable monocotyledonous models for plants possessing the C4 pathway of photosynthesis including sorghum,maize,sugarcane,switchgrass and Miscanthus×giganteus.Accurate partial least squares regression(PLSR)models to predict S.italica stem composition have been generated,based upon Fourier transform mid-infrared(FTIR)spectra and calibrated with wet chemistry determinations of ground S.italica stem material measured using a modified version of the US National Renewable Energy Laboratory(NREL)acid hydrolysis protocol.The models facilitated a high-throughput screening analysis for glucan,xylan,Klason lignin and acid soluble lignin(ASL)in a collection of 183 natural S.italica variants and clustered them into classes,some possessing unique chemotypes.The predictive models provide a highly efficient screening tool for large scale breeding programs aimed at identifying lines or mutants possessing unique cell wall chemotypes.Genes encoding key catalytic enzymes of the lignin biosynthesis pathway exhibit a high level of conservation with matching expression profiles,measured by RT-q PCR,among accessions of S.italica,which closely mirror profiles observed in the different developmental regions of an elongating internode of S.viridis by RNASeq.
基金Project supported by the National Key Scientific Instrument and Equipment Development,China(Grant No.2014YQ060537)the National Key Research and Development Program,China(Grant No.2016YFC0201103)
文摘A compact prototype based on mid-infrared wavelength modulation spectroscopy(WMS)is developed for the simul-taneous monitoring of NO,NO2,and NH3 in the urban area.Three quantum cascade lasers(QCLs)with central frequencies around 1900.0 cm^-1,1600.0 cm^-1,and 1103.4 cm^-1are used for NO,NO2,and NH3detections,respectively,by timedivision multiplex.An open-path multi-pass cell of 60-m optical path length is applied to the instrument for high sensitivity and reducing the response time to less than 1 s.The prototype achieves a sub-ppb detection limit for all the three target gases with an average time of about 100 s.The instrument is installed in the Jiangsu environmental monitoring center to conduct performance tests on ambient air.Continuous 24-hour measurements show good agreement with the results of a reference instrument based on the chemiluminescence technique.
基金supported by the National Key R&D Program of China(Nos.2016YFD0700101 and 2016YFC0303902)the National Natural Science Foundation of China(Nos.61775079,61627823 and 61307124)+3 种基金the Science and Technology Planning Project of Guangdong Province,China(No.2017A020216011)the Science and Technology Development Program of Jilin Province,China(No.20140307014SF)the Industrial Innovation Program of Jilin Province,China(No.2017C027)Changchun Municipal Science and Technology Bureau,China(No.14KG022)
文摘A dual-gas sensor system is developed for CO and CO_2 detection using a single broadband light source, pyroelectric detectors and time-division multiplexing(TDM) technique. A stepper motor based rotating system and a single-reflection spherical optical mirror are designed and adopted for realizing and enhancing dual-gas detection. Detailed measurements under static detection mode(without rotation) and dynamic mode(with rotation) are performed to study the performance of the sensor system for the two gas samples. The detection period is 7.9 s in one round of detection by scanning the two detectors. Based on an Allan deviation analysis, the 1σ detection limits under static operation are 3.0 parts per million(ppm) in volume and 2.6 ppm for CO and CO_2, respectively, and those under dynamic operation are 9.4 ppm and 10.8 ppm for CO and CO_2, respectively. The reported sensor has potential applications in various fields requiring CO and CO_2 detection such as in the coal mine.
基金supported by the National Natural Science Foundation of China(Nos.21205145,21276006,21036009)the Open Funds of State Key Laboratory of Chemo/Biosensing and Chemometrics of Hunan University(No.201111)+1 种基金the Special Fund for Basic Scientific Research of Central Colleges,South-Central University for Nationalities(Nos.CZZ10005 and CZQ11012)the 'Five-twelfth' National Science and Technology Support Program (No.2012BAI27B00)
文摘Rapid and sensitive recognition of herbal pieces according to different concocted processing is crucial to quality control and pharmaceutical effect. Near-infrared (NIR) and mid-infrared (MIR) technology combined with supervised pattern recognition based on partial least-squares discriminant analysis (PLSDA) was attempted to classify and recognize six different concocted processing pieces of 600 Areca catechu L. samples and the influence of fingerprint information preprocessing methods on recognition performance was also investigated in this work. Recognition rates of 99.24%, 100% and 99.49% for original fingerprint, multiple scatter correct (MSC) fingerprint and second derivative (2nd derivative) fingerprint of NIR spectra were achieved by PLSDA models, respectively. Meanwhile, a perfect recognition rate of 100% was obtained for the above three fingerprint models of MIR spectra. In conclusion, PLSDA can rapidly and effectively extract otherness of fingerprint information from NIR and MIR spectra to identify different concocted herbal pieces ofA. catechu.
基金supported by the National Natural Science Foundation of China(Grant No.61775050).
文摘Mid-infrared(MIR)-polarized thermal emission has broad applications in areas such as molecular sensing,information encryption,target detection,and optical communication.However,it is difficult for objects in nature to produce polarized thermal emission.Moreover,simultaneously generating and modulating broadband MIR thermal emission with both circular and linear polarization is even more difficult.We present a chiral plasmonic metasurface emitter(CPME)composed of asymmetric L-shaped and I-shaped antennas.The CPME consists of In_(3)SbTe_(2)(IST)phase-change material(PCM)antennas,an Al_(2)O_(3) dielectric layer,and an Au substrate.It is demonstrated that the CPME can selectively emit polarized light with different polarization states.Numerical simulations show that the CPME can achieve full Stokes parameter control of MIR thermal emission.By changing the state of the PCM IST,the spectral emissivity of 0 deg,45 deg,90 deg,and 135 deg linearly polarized(LP)lights and left-handed/right-handed circularly polarized(LCP/RCP)lights can be adjusted.In the crystalline state,the CPME exhibits the total degree of polarization(DoP)greater than 0.5 in the wavelength range of 3.4 to 5.3μm,the degree of linear polarization(DoLP)greater than 0.4 in the range of 3.0 to 5.1μm,and the degree of circular polarization(DoCP)greater than 0.4 in the range of 4.5 to 5.6μm.The physical mechanism of polarized emission has been investigated fully based on the near-field intensity distribution and power loss distribution.Finally,the potential applications of the designed CPME in infrared polarization detection and antidetection are verified through numerical calculations.
基金Supported by the National Natural Science Foundation of China(12064028)Jiangxi Provincial Natural Science Foundation(20232BAB201045).
文摘Electro-Optic Sampling(EOS)detection technique has been widely used in terahertz science and tech⁃nology,and it also can measure the field time waveform of the few-cycle laser pulse.Its frequency response and band limitation are determined directly by the electro-optic crystal and duration of the probe laser pulse.Here,we investigate the performance of the EOS with thin GaSe crystal in the measurement of the mid-infrared few-cycle la⁃ser pulse.The shift of the central frequency and change of the bandwidth induced by the EOS detection are calcu⁃lated,and then the pulse distortions induced in this detection process are discussed.It is found that this technique produces a red-shift of the central frequency and narrowing of the bandwidth.These changings decrease when the laser wavelength increases from 2μm to 10μm.This work can help to estimate the performance of the EOS de⁃tection technique in the mid-infrared band and offer a reference for the related experiment as well.
基金supported by the National Natural Science Foundation China(No.42022051,No.U21A2028)Youth Innovation Promotion Association of the Chinese Academy of Sciences(No.Y202089)the HFIPS Director's Fund(No.YZJJ202101,No.BJPY2023A02).
文摘Optical frequency combbased Fourier transform spectroscopy has the features of broad spectral bandwidth,high sensitivity,andmultiplexed trace gas detection,which has valuable application potential in the fields of precision spectroscopy and trace gas detection.Here,we report the development of a mid-infrared Fourier transform spectrometer based on an optical frequency comb combined with a Herriott-type multipass cell.Using this instrument,the broadband absorption spectra of several important molecules,including methane,acetylene,water molecules and nitrous oxide,are measured by near real-time data acquisition in the 2800-3500 cm^(-1)spectral region.The achieved minimum detectable absorption of the instrument is 4.4×10^(-8)cm^(-1)·Hz^(-1/2)per spectral element.Broadband spectra of H_(2)0 are fited using the Voigt profile multispectral fitting technique and the consistency of the concentration inversion is 1%.Our system also enables precise spectroscopic measurements,and it allows the determination of the spectral line positions and upper state constants of N_(2)O in the(0002)-(1000)band,with results in good agreement with those reported by Toth[Appl.Opt.30,5289(1991)].
基金supported by the Shanghai Pilot Program for Basic Research (Grant No. TQ20220104)the National Natural Science Foundation of China (Grant Nos. 62175064, 62235019, and 62035005)+4 种基金the Innovation Program for Quantum Science and Technology (Grant No. 2023ZD0301000)the Shanghai Municipal Science and Technology Major Project (Grant No. 2019SHZDZX01)the Natural Science Foundation of Chongqing (Grant Nos. CSTB2023NSCQ-JQX0011 and CSTB2022TIAD-DEX0036)the Fundamental Research Funds for the Central Universitiesthe China Postdoctoral Science Foundation (Grant No. 2024M760918)
文摘Mid-infrared(MIR)spectral imaging enables precise target identification and analysis by capturing rich chemical fingerprints,which calls for high-sensitivity broadband MIR imagers at room temperature.Here,we devise and implement a continuous-wave pumping MIR upconversion imaging system based on externalcavity enhancement,which favors a large field of view,a low cavity loss,and a high spectral resolution.The involved optical cavity is constructed in an integrated fashion by utilizing one crystal facet as a cavity mirror,which allows a 43-fold power enhancement for the single-longitudinal-mode pump at 1064 nm.In combination with the chirped-poling crystal design,high-fidelity and wide-field spectral imaging mapping is permitted to facilitate an acceptance angle of up to 28.5 deg over a spectral coverage of 2.5 to 5μm.Moreover,a thermal locking approach is used to stabilize the cavity at high-power operation,eliminating active feedback and ensuring long-term stability.A proof-of-principle demonstration is presented to showcase real-time observation of CO_(2)gas injection dynamics.The implemented MIR upconversion imager features wide-field operation,high detection sensitivity,and compact footprint,which would benefit subsequent applications,including environment monitoring,gas leakage inspection,and medical diagnostics.
基金supported by the Innovation Program for Quantum Science and Technology(Grant No.2023ZD0301000)the Chongqing Technology Innovation and Application Develop-ment Project(Grant No.CSTB2022TIAD-DEX0031).
文摘Tunable mid-infrared lasers are essential for optical sensing and imaging.Existing technologies,however,face challenges in simultaneously achieving broadband spectral tunability and ultra-rapid scan rates,limiting their utility in dynamic scenarios such as real-time characterization of multiple molecular absorption bands.We present a high-speed approach for broadband wavelength sweeping in the mid-infrared region,leveraging spectral focusing via difference-frequency generation between a chirped fiber laser and an asynchronous,frequency-modulated electro-optic comb.This method enables pulse-to-pulse spectral tuning at a speed of 5.6 THz∕μs with 380 elements.Applied to spectroscopic sensing,our technique achieves broad spectral coverage(2600 to 3780 cm−1)with moderate spectral resolution(8 cm−1)and rapid acquisition time(-6.3μs).Notably,the controllable electro-optic comb facilitates high scan rates of up to 2 Mscans∕s across the full spectral range(corresponding to a speed of 60 THz∕μs),with trade-offs in number of elements(-30)and spectral point spacing or resolution(33 cm−1).Nevertheless,these capabilities make our platform highly promising for applications such as flow cytometry,chemical reaction monitoring,and mid-infrared ranging and imaging.
文摘In this paper,a tunable metamaterial absorber based on a Dirac semimetal is proposed.It consists of three different structures,from top to bottom,namely a double semicircular Dirac semimetal resonator,a silicon dioxide substrate and a continuous vanadium dioxide(VO_(2))reflector layer.When the Fermi energy level of the Dirac semimetal is 10 meV,the absorber absorbs more than 90%in the 39.06-84.76 THz range.Firstly,taking advantage of the tunability of the conductivity of the Dirac semimetal,dynamic tuning of the absorption frequency can be achieved by changing the Fermi energy level of the Dirac semimetal without the need to optimise the geometry and remanufacture the structure.Secondly,the structure has been improved by the addition of the phase change material VO_(2),resulting in a much higher absorption performance of the absorber.Since VO_(2)is a temperature-sensitive metal oxide with an insulating phase below the phase transition temperature(about 68℃)and a metallic phase above the phase transition temperature,this paper also analyses the effect of VO_(2)on the absorptive performance at different temperatures,with the aim of further improving absorber performance.
文摘The Savitzky-Golay(SG)filter,which employs polynomial least-squares approximations to smooth data and estimate derivatives,is widely used for processing noisy data.However,noise suppression by the SG filter is recognized to be limited at data boundaries and high frequencies,which can significantly reduce the signal-to-noise ratio(SNR).To solve this problem,a novel method synergistically integrating Principal Component Analysis(PCA)with SG filtering is proposed in this paper.This approach avoids the is-sue of excessive smoothing associated with larger window sizes.The proposed PCA-SG filtering algorithm was applied to a CO gas sensing system based on Cavity Ring-Down Spectroscopy(CRDS).The perform-ance of the PCA-SG filtering algorithm is demonstrated through comparison with Moving Average Filtering(MAF),Wavelet Transformation(WT),Kalman Filtering(KF),and the SG filter.The results demonstrate that the proposed algorithm exhibits superior noise reduction capabilities compared to the other algorithms evaluated.The SNR of the ring-down signal was improved from 11.8612 dB to 29.0913 dB,and the stand-ard deviation of the extracted ring-down time constant was reduced from 0.037μs to 0.018μs.These results confirm that the proposed PCA-SG filtering algorithm effectively improves the smoothness of the ring-down curve data,demonstrating its feasibility.
基金financially supported by the National Natural Science Foundation of China (22350410386,W2412116,22375200,U22A202175,21961142006)。
文摘Exploring cost-effective and efficient catalysts for oxygen reduction reaction(ORR)poses a significant challenge,espe-cially in the pursuit of alternatives to precious metals like platinum.Significant advancements have driven electrochem-ists to develop efficient ORR catalysts using abundant materials,particularly iron(Fe)-based,known for their exceptional performance in ORR.While the crucial function of Fe in boosting ORR catalytic activity is recognized,the connection between material attributes and catalytic performance remains enigmatic.Understanding the dynamic processes involved in oxygen electrocatalysis is paramount for designing precious-metals-free ORR electrocatalysts.Mössbauer spectroscopy stands out as a powerful technique for deciphering the structural characteristics of Fe species in catalysis,facilitating the identification of active sites and the clarification of catalytic mechanisms.By showcasing noteworthy case studies within this review,we demonstrate the application of in-situ/operando 57Fe Mössbauer spectroscopy across diverse Fe-involved materials in ORR catalysis.This sheds light on various aspects of ORR catalysis,such as identifying active sites,assessing stability,and understanding the reaction mechanism.Our inquiry drives towards the opportunities and hurdles associ-ated with Mössbauer spectroscopy,unveiling potential breakthroughs and avenues for enhancement within this pivotal research realm.
基金supported by the National Key R&D Program of China(No.2021YFA1601003)the financial support of the SSRF PhaseⅡproject.
文摘This paper describes the design and performance of the tender energy spectroscopy beamline(BL16U1),a phase Ⅱ beamline,at the Shanghai Synchrotron Radiation Facility.The beamline,based on an in-vacuum undulator source with 26 mm period,provides an operable energy range between 2.1 keV and 16 keV,covering the K-edges of P to Rb and L3-edges of Zr to Bi.The principal optical elements of the beamline are a toroidal mirror,a liquid nitrogen-cooled double-crystal monochromator,a high-harmonic-rejection mirror,and two pairs of Kirkpatrick–Baez(KB)mirrors.Three end-stations,including non-focusing,microprobe,and sub-microprobe types,are installed on the beamline.X-ray fluorescence(XRF)and X-ray absorption spectroscopy(XAS),including X-ray absorption near-edge structure(XANES)and extended X-ray absorption fine structure(EXAFS),are performed under vacuum or He atmosphere at the non-focusing end-station(with a beam spot size of∼670μm×710μm).Using two KB mirrors systems,micro-XRF(μXRF)mapping and micro-XANES(μXANES)studies can be performed with a spot size of approximately∼3.3μm×1.3μm at the microprobe end-station and with a smaller spot size of∼0.5μm×0.25μm at the sub-microprobe end-station.The non-focusing end-station was officially opened to users in January 2024.The microprobe and sub-microprobe end-stations will be opened to users in the near future.This paper presents the characteristics,short-term technical developments,and early experimental results of this new beamline.
文摘With the development of mid-infrared (MIR) photoelectric devices, mid-infrared spectroscopy has become one of the important methods for non-invasive detection of blood glucose. The mid-infrared region (4000 - 400 cm<sup>-1</sup>) has the well-known fingerprint region (1200 - 800 cm<sup>-1</sup>) of glucose, which has clearer characteristic absorption peaks and better specificity. There is a lot of molecular information about glucose in the MIR. The non-invasive detection of blood glucose by mid-infrared spectroscopy needs to achieve certain accuracy, and the quantitative model is an important factor affecting the accuracy of glucose detection. In this paper, the samples of imitation solution containing only glucose and the samples of imitation mixed solution are taken as the research objects, and the mid-infrared spectral data of the samples are collected. The full spectrum partial least squares Regression (PLSR) model, SNV + Ctr-PLSR model, MSC + Ctr-PLSR model, and convolutional neural networks (CNN) model of 3000 - 900 cm<sup>-1</sup> band were constructed. Full spectrum PLS model and CNN model of 1200 - 900 cm<sup>-1</sup> band were constructed. The experimental results show that the optimal model of the two bands is CNN, then the correlation coefficient of prediction set (Rp) of 3000 - 900 cm<sup>-1</sup> band is 0.95, and the root mean square error of pre-diction set (RMSEP) value is 22.10. The Rp of 1200 - 900 cm<sup>-1</sup> band is 0.95, and the RMSEP value is 22.54. The research results show that CNN is a promising method, which has higher accuracy than PLSR, and is especially suitable for modeling human complex environment. In addition, the study provides a theoretical and practical basis for CNN in feature selection and model interpretation.
基金jointly funded by the Strategic Priority Research Program of the Chinese Academy of Sciences(grant No.XDA0430301)the National Natural Science Foundation of China(grant Nos.42130109,41973059)。
文摘The formation of copper deposits is closely related to hydrothermal processes.Understanding the migration of copper in hydrothermal fluids aids in reconstructing mineralization processes and deciphering deposit genesis.Copper primarily exists as Cu^(+)and Cu^(2+)in hydrothermal solutions,with redox conditions governing their interconversion.In chloride-rich geological fluids,Cu-Cl complexes are considered critical for copper transport.However,the specific types and valence transitions of Cu-Cl complexes under varying hydrothermal conditions remain poorly understood.This study employed in situ Raman spectroscopy to systematically analyze Cu+HCl and CuCl_(2)+K_(2)S_(2)O_(3)/H_(2) systems under saturated vapor pressure at 25-300℃,elucidating the effects of temperature,Cl^(-)concentration,and redox conditions on copper speciation.In the Cu^(+)HCl system,copper dissolved as monovalent Cu-Cl complexes.At high temperatures(>200℃),[CuCl_(2)]^(-)is the dominated species,whereas[CuCl_(3)]^(2-)becomes prevalent at lower temperatures and higher HCl concentrations.For the Cu^(2+)-Cl system,the dominant species transitioned from[Cu(H_(2)O)n]^(2+)(<50℃)to[CuCl_(4)]^(2-)(100℃)and further to[CuCl]^(+)and[CuCl_(2)]^(0) at 300℃.The introduction of reducing agents(K_(2)S_(2)O_(3)/H_(2))facilitated Cu^(2+)→Cu^(+)reduction,thereby stabilizing Cu^(+)-Cl complexes and inducing partial copper precipitation.The behavior of copper in chloriderich hydrothermal fluids observed in this study indicates that high-temperature oxidizing fluids facilitate Cu mobilization,while cooling and redox changes promote deposition and ore minerals formation.
基金supported by the National Natural Science Foundation of China(Nos.12027809,12350007)National Key R&D Program of China(Nos.2022YFA1605100,2023YFA1606403,and 2023YFE0101600)+1 种基金New Cornerstone Science Foundation through the XPLORER PRIZEfunding from the European Research Council(ERC)under the European Union’s Horizon 2020 research and innovation program under grant agreement No.679038.
文摘A RadioFrequency Quadrupole(RFQ)cooler-buncher system was developed and implemented in a collinear laser spectroscopy setup.This system converts a continuous ion beam into short bunches while enhancing the beam quality and reducing the energy spread.The functionality of the RFQ cooler buncher was verified through offline tests with stable rubidium and indium beams delivered from a surface ion source and a laser ablation ion source,respectively.Bunched ion beams with a full width at half maximum of approximately 2μs in the time-of-flight spectrum were successfully achieved with a transmission efficiency exceeding 60%.The implementation of the RFQ cooler-buncher system also significantly improved the overall transmission efficiency of the collinear laser spectroscopy setup.