期刊文献+
共找到4,471篇文章
< 1 2 224 >
每页显示 20 50 100
Studying a kind of portable ultra-bright microfocus x-ray source
1
作者 王凯歌 王雷 牛憨笨 《Chinese Physics B》 SCIE EI CAS CSCD 2009年第5期1807-1813,共7页
This paper studies the properties of a kind of portable ultra-bright microfocus x-ray source with the Monte-Carlo method in detail. The new x-ray source consists of an electron-emission system, an electrostatic focusi... This paper studies the properties of a kind of portable ultra-bright microfocus x-ray source with the Monte-Carlo method in detail. The new x-ray source consists of an electron-emission system, an electrostatic focusing system and a metal target. A crystal Lanthanum Hexaboride cathode, a Wehnelt grid and an extracted electrode compose the triode electrode electron-gun system. Two equal radius cylinder electrodes form the focusing system. The key factors determining the focus properties of the electron beam such as the ratio Dw/H, grid bias Vg, and the properties of the extracted electrode arc numerically studied. The calculated results reveal that when Dw/H, Vg, the length of the extracted electrode, and the distance between the grid and the extracted electrode equals 5, q).6 kV, 10 mm, and 8 mm respectively, the electron beam focal spot can be concentrated down to 9 μm in radius and a reasonable focal length about 72.5 mm can be achieved, at the same time, the cathode emission currents can be as high as 30 mA. 展开更多
关键词 microfocus x-ray source high brightness micro-focal spot Monte-Carlo method
原文传递
In-line phase contrast for weakly absorbing materials with a microfocus x-ray source
2
作者 章迪 李政 +2 位作者 黄志峰 禹爱民 沙薇 《Chinese Physics B》 SCIE EI CAS CSCD 2006年第8期1731-1737,共7页
For weakly absorbing materials, image contrast can be enhanced by phase contrast in formation. The effectiveness of the in-line phase contrast technique relies on its ability to record intensity data which contain inf... For weakly absorbing materials, image contrast can be enhanced by phase contrast in formation. The effectiveness of the in-line phase contrast technique relies on its ability to record intensity data which contain information on the x- ray's phase shift. Four kinds of approaches to the relationship between intensity distribution and phase shift axe reviewed and discussed. A micro-focal x-ray source with high geometrical magnification is used to acquire phase contrast images. A great improvement on image quality is shown and geometrical parameters axe modified for comparison between different imaging positions. 展开更多
关键词 in-line phase contrast intensity distribution microfocus Fresnel diffraction
原文传递
Influence of tube voltage and current on in-line phase contrast imaging using a microfocus x-ray source
3
作者 李晨 李政 +1 位作者 禹爱民 黎成权 《Chinese Physics B》 SCIE EI CAS CSCD 2007年第8期2319-2324,共6页
In-line x-ray phase contrast imaging has attracted much attention due to two major advantages: its effectiveness in imaging weakly absorbing materials, and the simplicity of its facilities. In this paper a comprehens... In-line x-ray phase contrast imaging has attracted much attention due to two major advantages: its effectiveness in imaging weakly absorbing materials, and the simplicity of its facilities. In this paper a comprehensive theory based on Wigner distribution developed by Wu and Liu [Med. Phys. 31 2378-2384 (2004)] is reviewed. The influence of x-ray source and detector on the image is discussed. Experiments using a microfocus x-ray source and a CCD detector are conducted, which show the role of two key factors on imaging: the tube voltage and tube current. High tube current and moderate tube voltage are suggested for imaging. 展开更多
关键词 x-ray in-line phase contrast imaging Wigner distribution
原文传递
Effects of Tube Voltage on Phase-Contrast Imaging for Different Microfocus X-Ray Tubes
4
作者 Jianbao Gui Zhanli Hu +1 位作者 Peter Z. Wu Hairong Zheng 《Engineering(科研)》 2013年第10期590-594,共5页
In the past decade, phase-contrast imaging (PCI) has become a hot research with an increased improvement of the image contrast with respect to conventional absorption radiography. In this paper, effects of tube voltag... In the past decade, phase-contrast imaging (PCI) has become a hot research with an increased improvement of the image contrast with respect to conventional absorption radiography. In this paper, effects of tube voltage (kVp) on propagation-based phase-contrast imaging have been investigated with two types of microfocus x-ray tubes, a conventional sealed x-ray tube with the focal spot size of 13 - 20 μm and an open x-ray tube with minimum focal spot size less than 2 μm. A cooled x-ray CCD detector with the pixel size of 24 μm was used to acquire digital images. Two thin plastic sheets with different thickness were used as radiography phantoms. Two different phenomena were observed for the two x-ray tubes. For the open tube, phase-contrast effect has a slight drop with the increasing of tube voltage, however, it is opposite for the sealed tube. A further investigation indicates that the variation of focal spot size causes the abnormal result for the sealed tube. It also shows that phase-contrast effect is more sensitive to focal spot size than tube voltage. 展开更多
关键词 PHASE-CONTRAST Imaging EDGE Enhancement x-ray TUBE VOLTAGE
暂未订购
Optical characterization of X-ray polymer refractive lenses using a microfocus X-ray grating interferometer
5
作者 Dongxu Qin Lian Xue +5 位作者 Yifan Ding Ziwen Huang Lei Yang Zhaofeng Kang Keyi Wang Shuai Zhao 《Chinese Optics Letters》 2025年第4期143-148,共6页
Two-photon polymerization lithography is a technique that provides hundreds of nanometer resolution and full geometric freedom.Several X-ray polymer refractive lenses created by this technique were characterized using... Two-photon polymerization lithography is a technique that provides hundreds of nanometer resolution and full geometric freedom.Several X-ray polymer refractive lenses created by this technique were characterized using differential phase contrast imaging(DPCI)with a microfocus X-ray grating interferometer.The beam deflection angle and wavefront phase shift of the X-ray beam through the lens were obtained.Comparative tests using synchrotron radiation sources showed that the system could measure the surface shape of X-ray refractive lenses with an accuracy of 0.4μm.This study is important for improving the fabrication process and focusing performance of X-ray refractive lenses. 展开更多
关键词 differential phase contrast imaging x-ray polymer refractive lens microfocus x-ray grating interferometer optical characterization
原文传递
MAPPING THE DAMAGED ZONE AROUND THE CRACK TIP IN HIGH DENSITY POLYETHYLENE WITH SYNCHROTRON MICROFOCUS SMALL ANGLE X-RAY SCATTERING TECHNIQUE 被引量:3
6
作者 Hans-Friedrich Enderle Dieter Lilge +3 位作者 Stephan V.Roth Rainer Gehrke Jens Rieger 门永锋 《Chinese Journal of Polymer Science》 SCIE CAS CSCD 2010年第2期165-170,共6页
The structural changes around a crack tip in a high density polyethylene were investigated by means of scanning synchrotron microfocus small-angle X-ray scattering technique. The scattering data confirm the process of... The structural changes around a crack tip in a high density polyethylene were investigated by means of scanning synchrotron microfocus small-angle X-ray scattering technique. The scattering data confirm the process of craze structure development near a crack tip based on the evolution of voids. In addition, it was found that the main stress in the plastic zone near a crack tip exhibited a gradient distribution with respect to its strength and direction. The whole damaged area showed a strain distribution indicating a flow behavior toward the crack tip. 展开更多
关键词 High density polyethylene microfocus SAXS Crack tip Voids.
在线阅读 下载PDF
Scanning Microfocus Small Angle X-ray Scattering Study of the Avian Eggshell
7
作者 D. Lammie M. M. Bain +1 位作者 S. E. Solomon T. J. Wess 《Journal of Bionic Engineering》 SCIE EI CSCD 2006年第1期11-18,共8页
Synchrotron microfocus small angle X-ray scattering was used to investigate the nanostructure and microscopic variation of eggshells. It uses a microbeam allowing the ability to probe interactions between the organic ... Synchrotron microfocus small angle X-ray scattering was used to investigate the nanostructure and microscopic variation of eggshells. It uses a microbeam allowing the ability to probe interactions between the organic and inorganic components at nanometer level and is ideal for mapping over small areas to obtain a detailed analysis of structural variations. Thin sections of eggshells were scanned from the shell membrane (inner) to the cuticle (outer) surface. The data collected was used to produce two-dimensional maps showing microscopic changes within the different layers of the eggshell. The structural alterations ap- parently could have implications at the macroscopic level of the resulting eggshell. As the organic matrix is embedded within the eggshell this may contribute to the variations observed in calcite crystal form and texture, Structural information obtained about a biomaterial at different length scales is important in relating the structure to its functional properties. This knowledge and the principles behind the formation of biomaterials could be used in the attempt of bioengineering new systems. 展开更多
关键词 biomaterial EGGSHELL NANOSTRUCTURE microfocus small angle x-ray scattering
在线阅读 下载PDF
Lattice Anchoring Stabilizesα-FAPbI_(3) Perovskite for High-Performance X-Ray Detectors
8
作者 Yu-Hua Huang Su-Yan Zou +5 位作者 Cong-Yi Sheng Yu-Chuang Fang Xu-Dong Wang Wei Wei Wen-Guang Li Dai-Bin Kuang 《Nano-Micro Letters》 2026年第1期337-354,共18页
Formamidinium lead iodide(FAPbI_(3))perovskite exhibits an impressive X-ray absorption coefficient and a large carrier mobility-lifetime product(μτ),making it as a highly promising candidate for X-ray detection appl... Formamidinium lead iodide(FAPbI_(3))perovskite exhibits an impressive X-ray absorption coefficient and a large carrier mobility-lifetime product(μτ),making it as a highly promising candidate for X-ray detection application.However,the presence of larger FA^(+)cation induces to an expansion of the Pb-I octahedral framework,which unfortunately affects both the stability and charge carrier mobility of the corresponding devices.To address this challenge,we develop a novel low-dimensional(HtrzT)PbI_(3) perovskite featuring a conjugated organic cation(1H-1,2,4-Triazole-3-thiol,HtrzT^(+))which matches well with theα-FAPbI_(3) lattices in two-dimensional plane.Benefiting from the matched lattice between(HtrzT)PbI_(3) andα-FAPbI_(3),the anchored lattice enhances the Pb-I bond strength and effectively mitigates the inherent tensile strain of theα-FAPbI_(3) crystal lattice.The X-ray detector based on(HtrzT)PbI_(3)(1.0)/FAPbI_(3) device achieves a remarkable sensitivity up to 1.83×10^(5)μC Gy_(air)^(−1) cm^(−2),along with a low detection limit of 27.6 nGy_(air) s^(−1),attributed to the release of residual stress,and the enhancement in carrier mobility-lifetime product.Furthermore,the detector exhibits outstanding stability under X-ray irradiation with tolerating doses equivalent to nearly 1.17×10^(6) chest imaging doses. 展开更多
关键词 α-FAPbI_(3)perovskite Conjugated organic cation Lattice anchoring Phase stability x-ray detectors
在线阅读 下载PDF
基于高光谱和X-ray CT的苹果水心病无损检测方法
9
作者 于心圆 王振杰 +6 位作者 尤思聪 屠康 兰维杰 彭菁 朱丽霞 陈涛 潘磊庆 《智慧农业(中英文)》 2025年第4期108-118,共11页
[目的/意义]苹果“冰糖心”又称水心病,是一种常见的果实病害,严重的水心病果会随着储藏时间的增加发生霉变,造成食品安全隐患。为实现不同等级水心病苹果快速无损检测,本研究旨在构建有效的分级与可溶性固形物(Soluble Solids Content,... [目的/意义]苹果“冰糖心”又称水心病,是一种常见的果实病害,严重的水心病果会随着储藏时间的增加发生霉变,造成食品安全隐患。为实现不同等级水心病苹果快速无损检测,本研究旨在构建有效的分级与可溶性固形物(Soluble Solids Content,SSC)预测模型。[方法]本研究选取了230个富士苹果,其中正常、轻度、中度、重度水心苹果数量分别为113、61、47和9个,分别采集了400~1000 nm范围的反射光谱和X射线计算机断层成像(X-ray Computed Tomography,X-ray CT)数据,并测定了SSC含量。[结果和讨论]SSC随水心程度加剧呈上升趋势,重度水心苹果呈现更高的光谱反射率,X-ray CT扫描成像观察到水心区域的组织体积平均密度高于健康组织,基于三维重建算法实现不同等级水心苹果内部水心组织可视化分布。基于偏最小二乘判别分析(Partial Least Squares Discriminant Analysis,PLSDA)构建的不同水心程度苹果果实分级模型建模集和测试集准确率分别为98.7%和95.9%;构建不同水心程度苹果果实SSC回归模型,校正集决定系数(Correlation Coefficient of Calibration,R_(C)^(2))为0.962,均方根误差(Root Mean Squares Error of Calibration,RMSEC)为0.264,测试集决定系数(Correlation Coefficient of Prediction,R_(P)^(2))为0.879,均方根误差(Root Mean Squares Error of Prediction,RMSEP)为0.435。[结论]该研究构建的不同水心程度苹果果实分级模型能够实现苹果不同等级水心病的预测,构建的不同水心程度苹果果实SSC回归模型能够较好地预测苹果果实的SSC,为苹果水心病无损检测和品质评估提供了有效方法。 展开更多
关键词 水心病 高光谱成像技术 x-ray CT成像技术 可溶性固形物
在线阅读 下载PDF
Tests of Solar X-Ray Image Reconstruction:A New Index for Assessing Image Quality 被引量:1
10
作者 Zhen-Tong Li Wen-Hui Yu +2 位作者 Yang Su Wei Chen Wei-Qun Gan 《Research in Astronomy and Astrophysics》 2025年第3期76-89,共14页
Indirect X-ray modulation imaging has been adopted in a number of solar missions and provided reconstructed X-ray images of solar flares that are of great scientific importance.However,the assessment of the image qual... Indirect X-ray modulation imaging has been adopted in a number of solar missions and provided reconstructed X-ray images of solar flares that are of great scientific importance.However,the assessment of the image quality of the reconstruction is still difficult,which is particularly useful for scheme design of X-ray imaging systems,testing and improvement of imaging algorithms,and scientific research of X-ray sources.Currently,there is no specified method to quantitatively evaluate the quality of X-ray image reconstruction and the point-spread function(PSF)of an X-ray imager.In this paper,we propose percentage proximity degree(PPD)by considering the imaging characteristics of X-ray image reconstruction and in particular,sidelobes and their effects on imaging quality.After testing a variety of imaging quality assessments in six aspects,we utilized the technique for order preference by similarity to ideal solution to the indices that meet the requirements.Then we develop the final quality index for X-ray image reconstruction,QuIX,which consists of the selected indices and the new PPD.QuIX performs well in a series of tests,including assessment of instrument PSF and simulation tests under different grid configurations,as well as imaging tests with RHESSI data.It is also a useful tool for testing of imaging algorithms,and determination of imaging parameters for both RHESSI and ASO-S/Hard X-ray Imager,such as field of view,beam width factor,and detector selection. 展开更多
关键词 SUN flares-Sun x-rays gamma-rays-techniques image processing
在线阅读 下载PDF
Tests of Solar X-Ray Image Reconstruction:Study of X-Ray Imaging Algorithms and Reconstruction Parameters 被引量:1
11
作者 Wenhui Yu Yang Su +2 位作者 Zhentong Li Wei Chen Weiqun Gan 《Research in Astronomy and Astrophysics》 2025年第3期90-110,共21页
Imaging observations of solar X-ray bursts can reveal details of the energy release process and particle acceleration in flares.Most hard X-ray imagers make use of the modulation-based Fourier transform imaging method... Imaging observations of solar X-ray bursts can reveal details of the energy release process and particle acceleration in flares.Most hard X-ray imagers make use of the modulation-based Fourier transform imaging method,an indirect imaging technique that requires algorithms to reconstruct and optimize images.During the last decade,a variety of algorithms have been developed and improved.However,it is difficult to quantitatively evaluate the image quality of different solutions without a true,reference image of observation.How to choose the values of imaging parameters for these algorithms to get the best performance is also an open question.In this study,we present a detailed test of the characteristics of these algorithms,imaging dynamic range and a crucial parameter for the CLEAN method,clean beam width factor(CBWF).We first used SDO/AIA EUV images to compute DEM maps and calculate thermal X-ray maps.Then these realistic sources and several types of simulated sources are used as the ground truth in the imaging simulations for both RHESSI and ASO-S/HXI.The different solutions are evaluated quantitatively by a number of means.The overall results suggest that EM,PIXON,and CLEAN are exceptional methods for sidelobe elimination,producing images with clear source details.Although MEM_GE,MEM_NJIT,VIS_WV and VIS_CS possess fast imaging processes and generate good images,they too possess associated imperfections unique to each method.The two forward fit algorithms,VF and FF,perform differently,and VF appears to be more robust and useful.We also demonstrated the imaging capability of HXI and available HXI algorithms.Furthermore,the effect of CBWF on image quality was investigated,and the optimal settings for both RHESSI and HXI were proposed. 展开更多
关键词 techniques image processing-Sun flares-Sun x-rays gamma rays
在线阅读 下载PDF
Role of post-operative X-rays in distal-radius fractures among pediatric patients 被引量:1
12
作者 Ammar K Alomran Bandar A Alzahrani +4 位作者 Dana S Alamoud Layan S Alsultan Meshail M AlSaud Raneem G Althobaiti Badriah S Alruwaili 《World Journal of Orthopedics》 2025年第5期51-60,共10页
BACKGROUND In pediatric age group patients(<18 years old)treated operatively for distal radius/both bone fractures extending imaging beyond the initial postoperative period-particularly in uncomplicated cases-appea... BACKGROUND In pediatric age group patients(<18 years old)treated operatively for distal radius/both bone fractures extending imaging beyond the initial postoperative period-particularly in uncomplicated cases-appears to provide limited additional benefit.AIM To determine the necessary number of follow-up X-rays to use resources efficiently.METHODS Participants included in this study are pediatric age group patients who were treated operatively for distal radius/both bone fractures and were identified from a prospected collected data from the operating room database between the years 2009 and 2017.The data in the study included patients who had distal radius fractures and underwent fixation surgery(n=88).RESULTS When assessing the difference in the odds of conducting 1 or less X-ray compared to 2 or more X-rays in regard to the type of fixation,the only significant difference is the closed reduction fixation method.Patients who underwent closed reduction method procedure have significantly lower odds of having 2 more X-rays compared to those who didn’t have closed reduction method.Open reduction,internal fixation,and other fixation methods(close reduction and internal fixation,debridement,or epiphysiodesis)have higher odds of having two or more X-rays compared to patients who did not receive these methods;however,these odds are not statistically significant.CONCLUSION The findings of this study reveal notable absence of a statistically significant association between the frequency of postoperative X-rays and the outcome of children with distal radius fractures. 展开更多
关键词 x-ray Distal radius fractures PEDIATRICS ORTHOPEDIC FRACTURES
暂未订购
Diagnostics of temperature and blue-shifted velocity using soft X-ray spectra from the Macao Science Satellite-1 被引量:2
13
作者 JianPing Li Xu Yang +6 位作者 Dong Li JinHua Shen Lei Yang Ya Wang LianSheng Li YongQiang Shi HaiSheng Ji 《Earth and Planetary Physics》 2025年第3期740-751,共12页
Using the new soft X-ray data from the Macao Science Satellite-1,we studied a solar flare that occurred on 22 June 2023.We found that the centroids of the Ca(around 3.9 keV)and Fe(around 6.7 keV)line features exhibit ... Using the new soft X-ray data from the Macao Science Satellite-1,we studied a solar flare that occurred on 22 June 2023.We found that the centroids of the Ca(around 3.9 keV)and Fe(around 6.7 keV)line features exhibit a rapid shift toward higher energy channels during the flare's rising phase,followed by a gradual decrease during the decay phase.Through precise energy calibration,the centroids are determined with high accuracy.Temperature and velocity are then self-consistently derived by comparing the centroids with those calculated from the synthesized line features using the latest CHIANTI atomic database(ver.10.1).The calculated maximum velocity reaches up to 710±60 km s-1,which significantly exceeds the previously reported values.Our results suggest that the entire shift of soft X-ray lines may occur during the process of chromospheric evaporation. 展开更多
关键词 Macao Science Satellite-1 solar flares soft x-ray lines chromospheric evaporation
在线阅读 下载PDF
Investigation of bubbles escape behavior from low basicity mold flux for high-Mn high-Al steels using 3D X-ray microscope
14
作者 Qiang Liu Xiang Li +3 位作者 Shen Du Ming Gao Yanbin Yin Jiongming Zhang 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS 2025年第1期102-110,共9页
During the continuous casting process of high-Mn high-Al steels,various types of gases such as Ar need to escape through the top of the mold.In which,the behavior of bubbles traversing the liquid slag serves as a rest... During the continuous casting process of high-Mn high-Al steels,various types of gases such as Ar need to escape through the top of the mold.In which,the behavior of bubbles traversing the liquid slag serves as a restrictive link,closely associated with viscosity and the thickness of liquid slag.In contrast to two-dimensional surface observation,three-dimensional(3D)analysis method can offer a more intuitive,accurate,and comprehensive information.Therefore,this study employs a 3D X-ray microscope(3D-XRM)to obtained spatial distribution and 3D morphological characteristics of residual bubbles in mold flux under different basicity of liquid slag,different temperatures,and different holding times.The results indicate that as basicity of slag increases from 0.52 to 1.03,temperature increases from 1423 to 1573 K,the viscosity of slag decreases,the floating rate of bubbles increases.In addition,when holding time increases from 10 to 30 s,the bubbles floating distance increases,and the volume fraction and average equivalent sphere diameter of the bubbles solidified in the mold flux gradually decreases.In one word,increasing the basicity,temperature,and holding time leading to an increase in the removal rate of bubbles especially for the large.These findings of bubbles escape behavior provide valuable insights into optimizing low basicity mold flux for high-Mn high-Al steels. 展开更多
关键词 mold flux low basicity BUBBLES three-dimensional x-ray microscope VISCOSITY
在线阅读 下载PDF
CMOS direct conversion X-ray detector coupled with fluorinated liquid 被引量:1
15
作者 Shi-Hua Liu Chao-Song Gao +5 位作者 Xin Zhang Xiang-Ming Sun Meng Wu Zhi-Hui Han Tong Wan Yong-Shuai Ge 《Nuclear Science and Techniques》 2025年第1期59-68,共10页
X-ray detectors show potential applications in medical imaging,materials science,and nuclear energy.To achieve high detection efficiency and spatial resolution,many conventional semiconductor materials,such as amorpho... X-ray detectors show potential applications in medical imaging,materials science,and nuclear energy.To achieve high detection efficiency and spatial resolution,many conventional semiconductor materials,such as amorphous selenium,cadmium telluride zinc,and perovskites,have been utilized in direct conversion X-ray detectors.However,these semiconductor materials are susceptible to temperature-induced performance degradation,crystallization,delamination,uneven lattice growth,radiation damage,and high dark current.This study explores a new approach by coupling an FC40 electronic fluorinated liquid with a specialized high-resolution and high-readout-speed complementary metal-oxide-semiconductor(CMOS)pixel array,specifically the Topmetal II−chip,to fabricate a direct conversion X-ray detector.The fluorinated liquid FC40(molecular formula:C_(21)F_(48)N_(2))is an electronic medium that is minimally affected by temperature and displays no issues with uniform conductivity.It exhibits a low dark current and minimal radiation damage and enables customizable thickness in X-ray absorption.This addresses the limitations inherent in conventional semiconductor-based detectors.In this study,simple X-ray detector imaging tests were conducted,demonstrating the excellent coupling capability between FC40 electronic fluorinated liquid and CMOS chips by the X-ray detector.A spatial resolution of 4.0 lp/mm was measured using a striped line par card,and a relatively clear image of a cockroach was displayed in the digital radiography imaging results.Preliminary test results indicated the feasibility of fabricating an X-ray detector by combining FC40 electronic fluorinated liquid and CMOS chips.Owing to the absence of issues related to chip-material coupling,a high spatial resolution could be achieved by reducing the chip pixel size.This method presents a new avenue for studies on novel liquid-based direct conversion X-ray detectors. 展开更多
关键词 FC40 electronic fluorinated liquid CMOS pixel chip x-ray detector Spatial resolution
在线阅读 下载PDF
Experimental Observing Damage Evolution in Cement Pastes Exposed to External Sulfate Attack by in situ X-ray Computed Tomography
16
作者 WU Min CAO Kailei +4 位作者 XIAO Weirong YU Zetai CAO Jierong DING Qingjun LI Jinhui 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2025年第1期164-170,共7页
The paper presents experimental investigation results of crack pattern change in cement pastes caused by external sulfate attack(ESA).To visualize the formation and development of cracks in cement pastes under ESA,an ... The paper presents experimental investigation results of crack pattern change in cement pastes caused by external sulfate attack(ESA).To visualize the formation and development of cracks in cement pastes under ESA,an X-ray computed tomography(X-ray CT)was used,i e,the tomography system of Zeiss Xradia 510 versa.The results indicate that X-CT can monitor the development process and distribution characteristics of the internal cracks of cement pastes under ESA with attack time.In addition,the C3A content in the cement significantly affects the damage mode of cement paste specimens during sulfate erosion.The damage of ordinary Portland cement(OPC)pastes subjected to sulfate attack with high C3A content are severe,while the damage of sulfate resistant Portland cement(SRPC)pastes is much smaller than that of OPC pastes.Furthermore,a quadratic function describes the correlation between the crack volume fraction and development depth for two cement pastes immermed in sulfate solution. 展开更多
关键词 CONCRETE external sulfate attack damage evolution situ x-ray computed tomography
原文传递
耐张线夹X-ray无损探伤机器人设计及应用
17
作者 姜传霏 尚鑫 +3 位作者 张欣伟 黄志建 莫剑波 陈翠珠 《机床与液压》 北大核心 2025年第17期85-91,共7页
为提高高压输电线路耐张线夹无损探伤作业的效率和安全性,增加电力系统的稳定性,针对带电作业的电磁环境进行分析,自主设计X-ray无损探伤机器人。基于功能模块分解实现自上线机构、线路行走机构、X光检测机械臂及电磁兼容系统的设计,开... 为提高高压输电线路耐张线夹无损探伤作业的效率和安全性,增加电力系统的稳定性,针对带电作业的电磁环境进行分析,自主设计X-ray无损探伤机器人。基于功能模块分解实现自上线机构、线路行走机构、X光检测机械臂及电磁兼容系统的设计,开展核心零部件和等电位过程的电磁仿真分析,初步完成探伤机器人样机研制并进行220 kV带电作业实验。开发的无损探伤机器人具有轻量化设计、结构紧凑、操控简单、精准高效以及位姿灵活等特点,可实现带电线路一键自动上下线、快速跨越障碍物、保持通信流畅、实时成像等功能,在高压输电线路无损探伤作业领域具有广阔的应用前景。 展开更多
关键词 机器人 耐张线夹 x-ray无损探伤
在线阅读 下载PDF
Laboratory-based tender X-ray spectrometer for X-ray absorption fine structure measurements
18
作者 Hai-Sheng Yu Jian-Qiu Zhu +6 位作者 Jia-Xing Wu Yao-Tian Guo Song Li Yan Zhang Xiao-Xu Qian Jian-Qiang Wang Lin-Juan Zhang 《Nuclear Science and Techniques》 2025年第8期58-66,共9页
This study describes the design and performance of a laboratory-based tender X-ray spectrometer for X-ray absorption spectroscopy.The system enables effective absorption spectra to be measured within the 2.0-9.0 keV r... This study describes the design and performance of a laboratory-based tender X-ray spectrometer for X-ray absorption spectroscopy.The system enables effective absorption spectra to be measured within the 2.0-9.0 keV range using Rowland circle geometry;it covers the K edge of 3d transition metals,the L edge of lanthanides,and the M edge of actinides.The spectrometer is configured with a Rowland circle with a diameter of 500 mm and integrates a 250 W liquid metal jet X-ray source,spherical bent crystal analyzer,and energy-resolving silicon drift detector.The X-ray source is installed outside the vacuum chamber and remains fixed,while the analyzer crystals and detector are adjusted to change the Bragg angle,maintaining the Rowland condition.The energy resolution is 0.36-1.30 eV at 2.0-9.0 keV,and the monochromatic flux is approximately 5×10^(5) counts/s at 7040 eV.This study highlights the primary characteristics of the spectrometer and demon-strates its capabilities using selected experimental examples.The successful development of this spectrometer can facilitate research on actinide elements,which are often constrained in synchrotron radiation experiments owing to their radioactivity,thus fostering advancements in related nuclear energy fields. 展开更多
关键词 Laboratory x-ray spectroscopy XANES EXAFS Tender x-ray
在线阅读 下载PDF
Study on X-ray and electron-excited fluorescence spectroscopy of tungsten using TES
19
作者 Bing-Jun Wu Jing-Kai Xia +5 位作者 Shuo Zhang Robin Cantor Wen-Tao Wu Jin-Hua Li Xiao-Ming Xie Zhi Liu 《Nuclear Science and Techniques》 2025年第4期119-126,共8页
In the exploration of celestial bodies,such as Mars,the Moon,and asteroids,X-ray fluorescence analysis has emerged as a critical tool for elemental analysis.However,the varying selection rules and excitation sources i... In the exploration of celestial bodies,such as Mars,the Moon,and asteroids,X-ray fluorescence analysis has emerged as a critical tool for elemental analysis.However,the varying selection rules and excitation sources introduce complexity.Specifically,these discrepancies can cause variations in the intensities of the characteristic spectral lines emitted by identical elements.These variations,compounded by the minimal energy spacing between these spectral lines,pose substantial challenges for conventional silicon drift detectors(SDD),hindering their ability to accurately differentiate these lines and provide detailed insights into the material structure.To overcome this challenge,a cryogenic X-ray spectrometer based on transition-edge sensor(TES)detector arrays is required to achieve precise measurements.This study measured and analyzed the K-edge characteristic lines of copper and the diverse L-edge characteristic lines of tungsten using a comparative analysis of the electron and X-ray excitation processes.For the electron excitation experiments,copper and tungsten targets were employed as X-ray sources,as they emit distinctive X-ray spectra upon electron-beam bombardment.In the photon excitation experiments,a molybdenum target was used to produce a continuous spectrum with the prominent Mo Kαlines to emit pure copper and tungsten samples.TES detectors were used for the comparative spectroscopic analysis.The initial comparison revealed no substantial differences in the Kαand Kβlines of copper across different excitation sources.Similarly,the Lαlines of tungsten exhibited uniformity under different excitation sources.However,this investigation revealed pronounced differences within the Lβline series.The study found that XRF spectra preferentially excite outer-shell electrons,in contrast to intrinsic spectra,owing to different photon and electron interaction mechanisms.Photon interactions are selection-ruledependent and involve a single electron,whereas electron interactions can involve multiple electrons without such limitations.This leads to varied excitation transitions,as evidenced in the observed Lβline series. 展开更多
关键词 x-ray spectra x-ray emission spectra and fluorescence Superconducting transition-edge sensor x-ray γ-ray spectrometers
在线阅读 下载PDF
Improvement of Lattice Parameter Accuracy in Single Crystal XRD Based on a Laser-Induced X-Ray Source
20
作者 LIU Jin WANG Qiannan LI Jiangtao 《高压物理学报》 北大核心 2025年第4期9-15,共7页
The lattice parameter,measured with sufficient accuracy,can be utilized to evaluate the quality of single crystals and to determine the equation of state for materials.We propose an iterative method for obtaining more... The lattice parameter,measured with sufficient accuracy,can be utilized to evaluate the quality of single crystals and to determine the equation of state for materials.We propose an iterative method for obtaining more precise lattice parameters using the interaction points for the pseudo-Kossel pattern obtained from laser-induced X-ray diffraction(XRD).This method has been validated by the analysis of an XRD experiment conducted on iron single crystals.Furthermore,the method was used to calculate the compression ratio and rotated angle of an LiF sample under high pressure loading.This technique provides a robust tool for in-situ characterization of structural changes in single crystals under extreme conditions.It has significant implications for studying the equation of state and phase transitions. 展开更多
关键词 lattice parameter measurement accuracy single crystal x-ray diffraction iterative algorithm high pressure ratio of compression
在线阅读 下载PDF
上一页 1 2 224 下一页 到第
使用帮助 返回顶部