The real-time screening of biomolecules and single cells in biochips is extremely important for disease prediction and diagnosis,cellular analysis,and life science research.Barcode biochip technology,which is integrat...The real-time screening of biomolecules and single cells in biochips is extremely important for disease prediction and diagnosis,cellular analysis,and life science research.Barcode biochip technology,which is integrated with microfluidics,typically comprises barcode array,sample loading,and reaction unit array chips.Here,we present a review of microfluidics barcode biochip analytical approaches for the high-throughput screening of biomolecules and single cells,including protein biomarkers,microRNA(miRNA),circulating tumor DNA(ctDNA),single-cell secreted proteins,single-cell exosomes,and cell interactions.We begin with an overview of current high-throughput detection and analysis approaches.Following this,we outline recent improvements in microfluidic devices for biomolecule and single-cell detection,highlighting the benefits and limitations of these devices.This paper focuses on the research and development of microfluidic barcode biochips,covering their self-assembly substrate materials and their specific applications with biomolecules and single cells.Looking forward,we explore the prospects and challenges of this technology,with the aim of contributing toward the use of microfluidic barcode detection biochips in medical diagnostics and therapies,and their large-scale commercialization.展开更多
We will be concerned with the mathematical modeling, numerical simulation, and shape optimization of micro fluidic biochips that are used for various biomedical applications. A particular feature is that the fluid flo...We will be concerned with the mathematical modeling, numerical simulation, and shape optimization of micro fluidic biochips that are used for various biomedical applications. A particular feature is that the fluid flow in the fluidic network on top of the biochips is in- duced by surface acoustic waves generated by interdigital transducers. We are thus faced with a multiphysics problem that will be modeled by coupling the equations of piezoelectricity with the compressible Navier-Stokes equations. Moreover, the fluid flow exhibits a multiscale character that will be taken care of by a homogenization approach. We will discuss and analyze the mathematical models and deal with their numerical solution by space-time discretizations featuring appropriate finite element approximations with respect to hierarchies of simplicial triangulations of the underlying computational domains. Simulation results will be given for the propagation of the surface acoustic waves on top of the piezoelectric substrate and for the induced fluid flow in the microchannels of the fluidic network. The performance of the operational behavior of the biochips can be significantly improved by shape optimization. In particular, for such purposes we present a multilevel interior point method relying on a predictor-corrector strategy with an adaptive choice of the continuation steplength along the barrier path. As a specific example, we will consider the shape optimization of pressure driven capillary barriers between microchannels and reservoirs.展开更多
基金supported by the National Key Research and Development Plan of China(2023YFB3210400)the Natural Science Innovation Group Foundation of China(T2321004)+3 种基金the National Natural Science Foundation of China(62174101)Shandong University Integrated Research and Cultivation Project(2022JC001)Key Research and Development Plan of Shandong Province(Major Science and Technology Innovation Project2022CXGC020501).
文摘The real-time screening of biomolecules and single cells in biochips is extremely important for disease prediction and diagnosis,cellular analysis,and life science research.Barcode biochip technology,which is integrated with microfluidics,typically comprises barcode array,sample loading,and reaction unit array chips.Here,we present a review of microfluidics barcode biochip analytical approaches for the high-throughput screening of biomolecules and single cells,including protein biomarkers,microRNA(miRNA),circulating tumor DNA(ctDNA),single-cell secreted proteins,single-cell exosomes,and cell interactions.We begin with an overview of current high-throughput detection and analysis approaches.Following this,we outline recent improvements in microfluidic devices for biomolecule and single-cell detection,highlighting the benefits and limitations of these devices.This paper focuses on the research and development of microfluidic barcode biochips,covering their self-assembly substrate materials and their specific applications with biomolecules and single cells.Looking forward,we explore the prospects and challenges of this technology,with the aim of contributing toward the use of microfluidic barcode detection biochips in medical diagnostics and therapies,and their large-scale commercialization.
基金support by the NSF under Grants No. DMS-0511611, DMS-0707602, DMS-0810156, DMS-0811153by the German National Science Foundation DFG within the Priority Program SPP 1253
文摘We will be concerned with the mathematical modeling, numerical simulation, and shape optimization of micro fluidic biochips that are used for various biomedical applications. A particular feature is that the fluid flow in the fluidic network on top of the biochips is in- duced by surface acoustic waves generated by interdigital transducers. We are thus faced with a multiphysics problem that will be modeled by coupling the equations of piezoelectricity with the compressible Navier-Stokes equations. Moreover, the fluid flow exhibits a multiscale character that will be taken care of by a homogenization approach. We will discuss and analyze the mathematical models and deal with their numerical solution by space-time discretizations featuring appropriate finite element approximations with respect to hierarchies of simplicial triangulations of the underlying computational domains. Simulation results will be given for the propagation of the surface acoustic waves on top of the piezoelectric substrate and for the induced fluid flow in the microchannels of the fluidic network. The performance of the operational behavior of the biochips can be significantly improved by shape optimization. In particular, for such purposes we present a multilevel interior point method relying on a predictor-corrector strategy with an adaptive choice of the continuation steplength along the barrier path. As a specific example, we will consider the shape optimization of pressure driven capillary barriers between microchannels and reservoirs.