期刊文献+
共找到56篇文章
< 1 2 3 >
每页显示 20 50 100
The effect of typical seawater cations on the adhesion of mussel protein Mefp-1 based on dissipative quartz crystal microbalance
1
作者 Futao ZHANG Chengjun SUN +3 位作者 Linqing XIE Fuqian LI Fenghua JIANG Jingxi LI 《Journal of Oceanology and Limnology》 2025年第1期274-285,共12页
Mussels are common anchoring organisms that adhere to the surfaces of various substrates with their byssus.The adhesion of mussel to substrates is contingent upon the presence of mussel foot proteins,of which Mytilus ... Mussels are common anchoring organisms that adhere to the surfaces of various substrates with their byssus.The adhesion of mussel to substrates is contingent upon the presence of mussel foot proteins,of which Mytilus edulis foot protein-1(Mefp-1)has been identified as the most abundant protein.It has been found that lipids are involved in the mussel adhesion process and can facilitate Mefp-1adhesion.In this research,the adhesion behavior of Mefp-1 on various substrate surfaces under the effect of typical seawater cations with or without the presence of lipid were investigated using a quartz crystal microbalance with dissipation(QCM-D).Results indicate that the presence of cations Ca^(2+),Mg^(2+),Na^(+),and K^(+)leads to varying degrees of reduction in the adhesion performance of Mefp-1 on different substrates.The degree of this reduction,however,was much alleviated in the presence of palmitic acid,which is involved in the mussel adhesion process.Therefore,the involvement of palmitic acid is advantageous for mussel protein adhesion to the substrate surface in the marine environment.This study illustrated the significant contribution of palmitic acid to mussel adhesion,which can help to better understand biofouling mechanisms and develop biomimetic adhesive materials. 展开更多
关键词 mussel adhesion quartz crystal microbalance with dissipation(QCM-D) typical seawater cations palmitic acid Mefp-1
在线阅读 下载PDF
Nanodiamond/Ti_(3)C_(2) MXene-coated quartz crystal microbalance humidity sensor with high sensitivity and high quality factor
2
作者 Yao Yao Qiao Chen +5 位作者 Yan-Qi Li Xian-He Huang Wei-Wei Ling Zhe-MiaoXie Jia-QiWang Chang-Ming Chen 《Rare Metals》 SCIE EI CAS CSCD 2024年第6期2719-2729,共11页
To address the challenge of achieving both high sensitivity and a high quality factor in quartz crystal microbalance(QCM)humidity sensors,a nanodiamond(ND)/Ti_(3)C_(2)MXene composite-coated QCM humidity sensor was fab... To address the challenge of achieving both high sensitivity and a high quality factor in quartz crystal microbalance(QCM)humidity sensors,a nanodiamond(ND)/Ti_(3)C_(2)MXene composite-coated QCM humidity sensor was fabricated.The material characteristics of ND,Ti_(3)C_(2)MXene,and ND/Ti_(3)C_(2)MXene composite were analyzed by transmission electron microscopy(TEM)and Fourier transform infrared(FTIR)spectroscopy.The experimental results demonstrated that the hydrophilic ND nanoparticles coated on Ti_(3)C_(2) MXene nanosheet prevented the self-stacking of Ti_(3)C_(2)MXene and enhanced the sensitivity of Ti_(3)C_(2) MXene-based QCM humidity sensor.Moreover,the high mechanical modulus of Ti_(3)C_(2) MXene material helped ND/Ti_(3)C_(2)MXene composite-coated QCM humidity sensor to achieve a high quality factor(>20,000).ND/Ti_(3)C_(2)MXene compositecoated QCM humidity sensor exhibited a sensitivity of 82.45 Hz/%RH,a humidity hysteresis of 1.1%RH,fast response/recovery times,acceptable repeatability,and good stability from 11.3%RH to 97.3%RH.The response mechanism of ND/Ti_(3)C_(2) MXene composite-coated QCM humidity sensor was analyzed in combination with a bi-exponential kinetic adsorption model.Finally,the potential application of ND/Ti_(3)C_(2)MXene composite-coated QCM humidity sensor was demonstrated through its frequency response to wooden blocks with different moisture contents. 展开更多
关键词 Humidity sensor Quartz crystal microbalance NANODIAMOND Ti_(3)C_(2)MXene High quality factor
原文传递
Self-assembled graphene oxide/polyethyleneimine films as high-performance quartz crystal microbalance humidity sensors 被引量:3
3
作者 Zhen Yuan Hui-Ling Tai +3 位作者 Yuan-Jie Su Guang-Zhong Xie Xiao-Song Du Ya-Dong Jiang 《Rare Metals》 SCIE EI CAS CSCD 2021年第6期1597-1603,共7页
As humidity is one of the most widely demanded environmental parameters,the precision of its detection is significant.An advanced humidity sensor will improve the validity of the humidity monitoring system.In this stu... As humidity is one of the most widely demanded environmental parameters,the precision of its detection is significant.An advanced humidity sensor will improve the validity of the humidity monitoring system.In this study,a facile chemical layer-by-layer self-assembly(CLS)method was developed for fabricating graphene oxide(GO)/polyethyleneimine(PEI)multilayer films.Owing to the chemical bonding between the PEI and GO,and the intrinsic stickiness of the PEI,layered films with different numbers of layers were successfully prepared using the CLS method and confirmed through ultraviolet-visible(UV-Vis)spectroscopy and the mass loading of quartz crystal microbalance(QCM).Morphological measurements revealed that the roughness and thickness of the films increased exponentially with the number of bilayers.The GO/PEI films were deposited on QCM electrodes using the CLS method to produce the humidity sensors.The humidity measurement results showed a high sensitivity(37.84 Hz/%RH)and rapid response/recovery(<5 s/8 s)of the optimal sensor,which was superior to that of recently developed QCM sensors. 展开更多
关键词 Humidity sensors Quartz crystal microbalance Graphene oxide POLYETHYLENEIMINE SELF-ASSEMBLY
原文传递
Rapid identification of spinal ventral and dorsal roots using a quartz crystal microbalance 被引量:1
4
作者 Tao Sui Jun Que +5 位作者 Dechao Kong Hao Xie Daode Wang Kun Shi Xiaojian Cao Xiang Li 《Neural Regeneration Research》 SCIE CAS CSCD 2013年第8期686-692,共7页
The fast and accurate identification of nerve tracts is critical for successful nerve anastomosis. Taking advantage of differences in acetylcholinesterase content between the spinal ventral and dorsal roots, we develo... The fast and accurate identification of nerve tracts is critical for successful nerve anastomosis. Taking advantage of differences in acetylcholinesterase content between the spinal ventral and dorsal roots, we developed a novel quartz crystal microbalance method to distinguish between these nerves based on acetylcholinesterase antibody reactivity. The acetylcholinesterase antibody was immobilized on the electrode surface of a quartz crystal microbalance and reacted with the acetylcholinesterase in sample solution. The formed antigen and antibody complexes added to the mass of the electrode inducing a change in frequency of the electrode. The spinal ventral and dorsal roots were distinguished by the change in frequency. The ventral and dorsal roots were cut into 1 to 2-mm long segments and then soaked in 250 pL PBS. Acetylcholinesterase antibody was immobilized on the quartz crystal microbalance gold electrode surface. The results revealed that in 10 minutes, both spinal ventral and dorsal roots induced a frequency change; however, the frequency change induced by the ventral roots was notably higher than that induced by the dorsal roots. No change was induced by bovine serum albumin or PBS. These results clearly demonstrate that a quartz crystal microbalance sensor can be used as a rapid, highly sensitive and accurate detection tool for the quick identification of spinal nerve roots intraoperatively. 展开更多
关键词 neural regeneration peripheral nerve injury basic research quartz crystal microbalance biosensor spinal nerve nerve tract ACETYLCHOLINESTERASE antigen-antibody reaction identification ANASTOMOSIS nerve repair grants-supported paper NEUROREGENERATION
暂未订购
Development of a QCM (Quartz Crystal Microbalance) Biosensor to the Detection of Aflatoxin B1 被引量:2
5
作者 Katia Spinella Lucia Mosiello +1 位作者 Giuseppe Palleschi Fabio Vitali 《Open Journal of Applied Biosensor》 2013年第4期112-119,共8页
In this study, we have used a direct immunoassay where the simple binding between antigen and an antibody is detected. Immunoassays were performed in a drop system, monitoring the frequency decrease of the quartz-crys... In this study, we have used a direct immunoassay where the simple binding between antigen and an antibody is detected. Immunoassays were performed in a drop system, monitoring the frequency decrease of the quartz-crystal microbalance device because of mass increasing during immunoreaction. The QCM sensor was coated on both sides by gold electrodes, only one side of the crystal (liquid side) was in contact with the solution;the other side (contact side) was always dry. We tested a piezoelectric immunosensor for aflatoxin B1 (AFLA-B1) mycotoxin detection through the immo- bilization of DSP-anti-AFLAB1 antibody (AFLA-B1-Ab anti AFLAB1) on gold-coated quartz crystals (AT-cut/5 MHz). The DSP (3,3’-Dithiodipropionic-acid-di-N-hydroxysuccinimide ester) was used for the covalent attachment of the proteins. The piezoelectric crystal electrodes were pretreated by DSP for 15 min, rinsed with water and dried in a gentle flow of nitrogen gas. Then the DSP-coated crystals were installed in a sample holder and exposed to the anti-AFLAB1 antibody and to the AFLA-BI. Frequency and resistance shifts (Δf and ΔR) were measured simultaneously. Δf versus AFLA-BI concentrations in the range of 0.5 - 10 ppb exhibited a perfect linear correlation with a coefficient of above 0.998. 展开更多
关键词 IMMUNOSENSOR QUARTZ Crystal microbalance AFLATOXIN B1 ANTIBODY Gold Electrodes
暂未订购
<i>In-Situ</i>Monitoring of Chemical Vapor Deposition from Trichlorosilane Gas and Monomethylsilane Gas Using Langasite Crystal Microbalance 被引量:1
6
作者 Hitoshi Habuka Yurie Tanaka 《Journal of Surface Engineered Materials and Advanced Technology》 2013年第1期61-66,共6页
Using the langasite crystal microbalance (LCM), the trends in film thickness produced by means of the chemical vapor deposition using trichlorosilane gas, monomethylsilane gas and their mixed gas were observed at 600?... Using the langasite crystal microbalance (LCM), the trends in film thickness produced by means of the chemical vapor deposition using trichlorosilane gas, monomethylsilane gas and their mixed gas were observed at 600?C and evaluated by comparison with the information from a transmission electron microscope (TEM). The crystalline silicon film thickness from trichlorosilane gas was comparable to that of an amorphous silicon carbide film from monomethylsilane gas. The film obtained from the gas mixture was amorphous and was the thinnest in this study. Because the thickness trend obtained by the LCM agreed with that by the TEM, the LCM is shown to be a convenient evaluation tool for the behavior of various film deposition. 展开更多
关键词 Chemical Vapor Deposition IN-SITU Measurement LANGASITE CRYSTAL microbalance
暂未订购
Quartz Crystal Microbalances for Evaluating Gas Motion Differences between Dichlorosilane and Trichlorosilane in Ambient Hydrogen in a Slim Vertical Cold Wall Chemical Vapor Deposition Reactor 被引量:1
7
作者 Mana Otani Toshinori Takahashi +3 位作者 Hitoshi Habuka Yuuki Ishida Shin-Ichi Ikeda Shiro Hara 《Advances in Chemical Engineering and Science》 2020年第3期190-200,共11页
A dichlorosilane gas and a trichlorosilane gas in ambient hydrogen were evaluated to show their different gas flow motions in a slim vertical cold wall chemical vapor deposition reactor for the Minimal Fab system. Thi... A dichlorosilane gas and a trichlorosilane gas in ambient hydrogen were evaluated to show their different gas flow motions in a slim vertical cold wall chemical vapor deposition reactor for the Minimal Fab system. This evaluation was performed for improving and controlling the film qualities and the productivities, using two quartz crystal microbalances (QCM) installed at the </span><span style="font-family:Verdana;">inlet and exhaust of the chamber by taking into account that the QCM frequency corresponds to the real time changes in the gas properties.</span><span style="font-family:Verdana;"> Typically, the time period approaching from the inlet to the exhaust was shorter for the trichlorosilane gas than that for the dichlorosilane gas. The trichlorosilane gas was shown to move like plug flow, while the dichlorosilane gas seemed to be well mixed in the entire chamber. 展开更多
关键词 Minimal Fab Chemical Vapor Deposition Reactor Quartz Crystal microbalance Silicon Epitaxial Growth TRICHLOROSILANE DICHLOROSILANE
在线阅读 下载PDF
Determination of Paclitaxel Solubility in Carbon Dioxide Using Quartz Crystal Microbalance
8
作者 焦真 陈志明 +1 位作者 吴有庭 马少玲 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2011年第2期227-231,共5页
A quartz crystal microbalance (QCM) is used to determine the phase equilibrium of paclitaxel-carbon dioxide system in the pressure range of 0-11 MPa and at temperatures of 35 °C,40 °C and 45 °C.The ex... A quartz crystal microbalance (QCM) is used to determine the phase equilibrium of paclitaxel-carbon dioxide system in the pressure range of 0-11 MPa and at temperatures of 35 °C,40 °C and 45 °C.The experimental results indicated that gaseous CO2 could be absorbed poorly into paclitaxel.The swelling of paclitaxel film in CO2 was observed before paclitaxel dissolved into supercritical carbon dioxide (ScCO2) with the increase of pressure.It was found that ScCO2 was not a good solvent for paclitaxel.The mole fraction of paclitaxel in ScCO2 was in the range of (4.5×10-9)-(7.8×10-9) under all our experimental conditions.Therefore,a much higher pressure than the CO2 supercritical point and/or a cosolvent must be used in any processes wherever paclitaxel dissolution in ScCO2 is required. 展开更多
关键词 PACLITAXEL carbon dioxide phase behavior quartz crystal microbalance
在线阅读 下载PDF
Quartz Crystal Microbalance Sensor Deposited with LB Films of Functional Polymers for the Detection of Phenols in Vapour Phase
9
作者 YAN Li and ZHOU Xi chun (New Materials Plant, Central China Normal University, Wuhan, 430079 Department of Environmental Science & Natural Resource , Wuhan University, Wuhan, 430072) 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 1998年第4期85-89,共5页
IntroductionInrecentyearsanincreasingdemandforenvironmentalmonitoringhasstimulatedana-lyticalchemiststomakeg... IntroductionInrecentyearsanincreasingdemandforenvironmentalmonitoringhasstimulatedana-lyticalchemiststomakegreaterefortstodev... 展开更多
关键词 Quartz crystal microbalance Chemical sensor Langmuir Blodgett film PHENOL Environmental monitoring
在线阅读 下载PDF
Electrochemical Quartz Crystal Microbalance(EQCM) Characterization of Electrodeposition and Catalytic Activity of Pd-based Electrocatalysts for Ethanol Oxidation
10
作者 KE Xi DENG Lu-lu +1 位作者 SHEN Pei-kang CUI Guo-feng 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2010年第3期443-448,共6页
Pd was electrochemically deposited on gold-coated quartz crystals at nanogram-level. The coulombic efficiency and initial nucleation and growth mechanism of potentiostatic Pd deposition were investigated via in situ e... Pd was electrochemically deposited on gold-coated quartz crystals at nanogram-level. The coulombic efficiency and initial nucleation and growth mechanism of potentiostatic Pd deposition were investigated via in situ electrochemical quartz crystal microbalance(EQCM). The coulombic efficieneies are 84%, 93% and 95% for Pd deposition at 0.3, 0.2 and 0.1 V(vs. SCE), respectively. The results of chronoamperometric measurements show that the Pd deposition proceeded by an instantaneous nucleation(at 0.3 V) or progressive nucleation(at 0.2 and 0.1 V) in a three-dimensional(3D) growth mode. The catalytic activity of Pd-based electrocatalyst for ethanol oxidation was characterized in an alkaline solution. It was found that the highest mass activity for ethanol oxidation on Pd-based electrocatalyst is 1.8× 10^4 A/(g Pd) deposited at 0.3 V for 5 s. 展开更多
关键词 Coulombic efficiency Nucleation and growth mechanism Electrochemical quartz crystal microbalance PALLADIUM Ethanol oxidation
在线阅读 下载PDF
Charge Transport Processes of Immobilized Heteropolyanions at Self-assembled Monolayer Modified Gold Electrode by Electrochemical Quartz Crystal Microbalance Measurement
11
作者 BU Xin-yuan JIAO Lian-sheng +1 位作者 HAN Dong-xue YANG Gui-fu 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2009年第4期537-542,共6页
The in situ electrochemical quartz crystal microbalance(EQCM) technique was used to investigate the ion transport of immobilized heteropolyanions at a self-assembled monolayer(SAM) modified gold electrode during e... The in situ electrochemical quartz crystal microbalance(EQCM) technique was used to investigate the ion transport of immobilized heteropolyanions at a self-assembled monolayer(SAM) modified gold electrode during electrochemical redox process.A mixed transfer method was presented to analyse the abnormal change of resonant frequency based on the simultaneous insertion/extraction of different ions.The results indicate that the migration of HSO4-anions was indispensable in the redox process of the heteropolyanions in a 1 mol/L H2SO4 solution and played a key role in the abnormal change of the resonant frequency.Such a change was attributed to different packing densities derived by means of differently immobilized methods. 展开更多
关键词 HETEROPOLYANION Charge transport Self-assembled monolayer Electrochemical quartz crystal microbalance
在线阅读 下载PDF
Real-Time Characterization of Fibrinogen Interaction with Modified Titanium Dioxide Film by Quartz Crystal Microbalance with Dissipation
12
作者 An-sha Zhao Zhao Wang +2 位作者 Xiao-hua Zhu Manfred F. Maitz Nan Huang 《Chinese Journal of Chemical Physics》 SCIE CAS CSCD 2014年第3期355-360,共6页
The adsorption of fibrinogen can be used as a quick indicator of surface haemocompatibility because of its prominent role in coagulation and platelet adhesion. In this work the molecular interaction between fibrinogen... The adsorption of fibrinogen can be used as a quick indicator of surface haemocompatibility because of its prominent role in coagulation and platelet adhesion. In this work the molecular interaction between fibrinogen and a modified titanium oxide surface/platelet has been studied by quartz crystal microbalanee with dissipation (QCM-D) in situ. In order to further characterize the conformation of adsorbed fibrinogen, αC and γ-chain antibody were used to check the orientation and denaturation of fibrinogen on solid surface. QCM-D investiga- tions revealed the fibrinogen have the trend to adsorb on hydropllilic surface in a side-on orientation by positively charged αC domains, which would reduce the exposure of platelet bonding site on γ chain and enable less platelet adhesion and be activated. These obser- vations suggest that certain conformations of adsorbed fibrinogen are less platelet adhesive than others, which opens a possibility for creating a non-platelet adhesive substrates. 展开更多
关键词 Quartz crystal microbalance with dissipation Fibrinogen adsorption Confor- mation change Blood platelet
在线阅读 下载PDF
In situ Investigation on Layer-by-Layer Deposition of Polyelectrolytes by Quartz Crystal Microbalance
13
作者 Yun-fengYan Guang-ming Liu +1 位作者 Ye-cang Tang Guang-zhao Zhang 《Chinese Journal of Chemical Physics》 SCIE CAS CSCD 北大核心 2008年第3期291-294,共4页
The effect of salt concentration on layer-by-layer deposition of poly(sodium 4-styrene sulfonate) (PSSS)/poly(vinylbenzyl trimethylammonium chloride) (PVTC) was investigated by use of quartz crystal microbalan... The effect of salt concentration on layer-by-layer deposition of poly(sodium 4-styrene sulfonate) (PSSS)/poly(vinylbenzyl trimethylammonium chloride) (PVTC) was investigated by use of quartz crystal microbalance with dissipation (QCM-D). The changes in frequency and dissipation demonstrate that the addition of NaC1 leads the thickness of PSSS/PVTC multilayer to increase. The deposition of PSSS/PVTC is dominated by surface charge overcompensation level at lower salt concentrations. However, it is mainly determined by the interpenetration of polyelectrolytes at a higher salt concentration, as reflected in the oscillation of dissipation change. 展开更多
关键词 POLYELECTROLYTE Layer-by-layer deposition Quartz crystal microbalance
在线阅读 下载PDF
Hybrid temperature effect on a quartz crystal microbalance resonator in aqueous solutions
14
作者 李强 谷宇 谢斌 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第6期411-416,共6页
The quartz crystal microbalance(QCM) is an important tool that can sense nanogram changes in mass. The hybrid temperature effect on a QCM resonator in aqueous solutions leads to unconvincing detection results. Contr... The quartz crystal microbalance(QCM) is an important tool that can sense nanogram changes in mass. The hybrid temperature effect on a QCM resonator in aqueous solutions leads to unconvincing detection results. Control of the temperature effect is one of the keys when using the QCM for high precision measurements. Based on the Sauerbrey's and Kanazawa's theories, we proposed a method for enhancing the accuracy of the QCM measurement, which takes into account not only the thermal variations of viscosity and density but also the thermal behavior of the QCM resonator. We presented an improved Sauerbrey equation that can be used to effectively compensate the drift of the QCM resonator. These results will play a significant role when applying the QCM at the room temperature. 展开更多
关键词 quartz crystal microbalance hybrid temperature effect aqueous solution
原文传递
Fabrication and evaluation of a portable and reproducible quartz crystal microbalance immunochip for label-free detection ofβ-lactoglobulin allergen in milk products
15
作者 Mingfei Pan Liping Hong +3 位作者 Jingying Yang Xiaoqian Xie Kaixin Liu Shuo Wang 《Food Science and Human Wellness》 SCIE 2022年第5期1315-1321,共7页
In this study,a label-free,portable and reproducible immunochip based on quartz crystal microbalance(QCM)was developed for the qualitative detection ofβ-lactoglobulin(β-LG),an allergen,in milk products.Experimental ... In this study,a label-free,portable and reproducible immunochip based on quartz crystal microbalance(QCM)was developed for the qualitative detection ofβ-lactoglobulin(β-LG),an allergen,in milk products.Experimental parameters in the fabrication and regeneration procedure such as pH of the coupling microenvironment,amount of anti-β-LG antibody and regeneration reagent were optimized in detail.Under optimal conditions,the proposed QCM immunochip exhibited good recognition of β-LG,with a calibration curve of ΔF=12.877 C_(β-LG)^(0.4809)(R^(2)=0.9982)and limit of detection of 0.04μg/mL.Additionally,this portable QCM immunochip had good stability,high specificity,and no obvious cross-reaction to three other milk proteins(α-casein,α-lactalbumin,and lactoferrin).It could compete a qualitative measurement within5 min,and could be reused at least ten times.In the β-LG analysis of actual milk samples,the developed QCM immunochip yielded reliable and accurate results,which correlated strongly with those from the standard HPLC method(R^(2)=0.9969).Thus,the portable,stable,and reproducible QCM immunochip developed in this study allowed the rapid,cost-effectively and sensitively measure theβ-LG in milk products. 展开更多
关键词 β-Lactoglobulin allergen Quartz crystal microbalance Immunochip Milk products
在线阅读 下载PDF
Monitoring the Growth Rate of HAp Crystal on the Surface of Ti/TiO_2 in SCS by a Quartz Crystal Microbalance
16
作者 Zhi-Hong ZHU~1 Xin-Yu SHEN~1 Peng WAN~1 Shan-Shan LIU~1 Hua TONG~(1,2Δ) Ji-Ming HU~11(Institute of Analytical and Biomedical Science, Collage of Chemistry and Molecular Science,Wuhan University, Wuhan 430072,China)2(Center of Nano-Sciences and Nano-Technology Reseach, Wuhan University, Wuhan 430072,China) 《生物医学工程学杂志》 EI CAS CSCD 北大核心 2005年第S1期55-56,共2页
关键词 Monitoring the Growth Rate of HAp Crystal on the Surface of Ti/TiO2 in SCS by a Quartz Crystal microbalance SCS TIO
暂未订购
Gravimetric Studies of Ni Electrodeposition with Additives from Deep Eutectic Solvents Using Electrochemical Quartz Crystal Microbalance EQCM
17
作者 K. Elttaib A. Benhmid 《Open Journal of Physical Chemistry》 2020年第2期87-98,共12页
The gravimetric analysis of electrodeposited nickel is demonstrated using electrochemical quartz crystal microbalance (EQCM) where the nickel coatings come from a solution of the metal chloride salt separately in eith... The gravimetric analysis of electrodeposited nickel is demonstrated using electrochemical quartz crystal microbalance (EQCM) where the nickel coatings come from a solution of the metal chloride salt separately in either a1choline chloride: 2 ethylene glycol (ethaline) or 1 choline chloride: 2 urea (reline) based ionic liquid. The possibility of adapting the Quartz Crystal Microbalance EQCM (which measures the mass attached to the electrode) to probe kinetics of electrochemically-driven solid state phase transformations has been explored in a Ni electrodeposition in absence and presence of complexing agents ethylene diamine en and acetylacetonate acac from both electrolytes ethaline and reline. The study shows that the current efficiency and the rate of deposition of nickel coatings obtained from ethaline and reline baths in absence of brighteners en and acac are different, and the addition of en and acac to both ionic liquid solutions results in a significant decrease current. And the associated growth rate will also be decreased, suggesting that the en acac stops the formation and growth of Ni nuclei. This suggests that the mechanism of growth is changed. 展开更多
关键词 ELECTRODEPOSITION Quartz Crystal microbalance Ethaline Reline Eth-ylene DIAMINE ACETYLACETONATE Current Efficiency IONIC Liquids
在线阅读 下载PDF
Application of Nanoparticles in Quartz Crystal Microbalance Biosensors
18
作者 Somayeh Heydari Gholam Hossein Haghayegh 《Journal of Sensor Technology》 2014年第2期81-100,共20页
Nanoparticles are playing an increasingly important role in the development of biosensors. The sensitivity and performance of biosensors are being improved by using Nanoparticles for their construction. The use of the... Nanoparticles are playing an increasingly important role in the development of biosensors. The sensitivity and performance of biosensors are being improved by using Nanoparticles for their construction. The use of these Nanoparticles has allowed the introduction of many new signal transduction technologies in biosensors. In this report, a comprehensive review of application of nanoparticles in Quartz Crystal Microbalance biosensors is presented. The main advantages of QCM in sensing fields include high sensitivity, high stability, fast response and low cost. In addition, it provides label-free detection capability for bio-sensing applications. Firstly, basic QCM’s design and characterization are described. Next, QCM biosensors based on modification of quartz substrate structure and their applications are digested. Nanoparticles and their utilizationin analysis are then illustrated. These include Nanoparticles in bio applications that cover Nanoparticles in Quartz Crystal Microbalance biosensors. 展开更多
关键词 NANOPARTICLES QUARTZ CRYSTAL microbalance QCM Biosensors REVIEW
在线阅读 下载PDF
Study of physisorption of volatile anesthetics on phos-pholipid monolayers using a highly sensitive quartz crystal microbalance (HS-QCM)
19
作者 Yasushi Yamamoto Zameer Shervani +6 位作者 Takatsugu Shimoaki Daisuke Yoshida Takashi Yokoyama Tadayoshi Yoshida Keijiro Taga Hiroshi Kamaya Issaku Ueda 《Journal of Biophysical Chemistry》 2011年第2期68-74,共7页
We have investigated the interactions between phospholipid monolayers and volatile anest-hatics. Two monolayers (dihexadecyl phosphate (DHP) and dipalmitoyl phosphatidyl choline (DPPC) and two anesthetics (halothane a... We have investigated the interactions between phospholipid monolayers and volatile anest-hatics. Two monolayers (dihexadecyl phosphate (DHP) and dipalmitoyl phosphatidyl choline (DPPC) and two anesthetics (halothane and enflurane) were used to observe these interac-tions using a highly sensitive quartz crystal microbalance (HS-QCM). The concentration of each anesthetic in aqueous solution was kept at 4 mM. The frequency of QCM showed no change when halothane was added to the DHP monolayer, however, it responded and de-creased when interaction occurred with DPPC monolayer. In case of enflurane addition the frequency decreased in both the monolayers of DHP and DPPC. The frequency change followed the following order of monolayer-anesthetic interactions: DHP-halothane <DPPC-halothane <DHP-enflurane <DPPC-enflurane. These re-sults showed that the response of anesthetics to the monolayers i.e. the physisorption not only depends on the anesthetic structure, the type of anesthetic hydrate formed, but also the hydrophilic polar group structure of the monolayer or the monolayer/water interface had an important role in physisorption. 展开更多
关键词 PHYSISORPTION PHOSPHOLIPID Monolayers Quartz Crystal microbalance (QCM) ANESTHETIC HYDRATE Monolayer-Water Interface
在线阅读 下载PDF
Quantitative measurement of p53-p53 antibody interactions by quartz crystal microbalance: A modelsystem for immunochemical calibration
20
作者 Donald H. Atha Vytas Reipa 《Journal of Biophysical Chemistry》 2012年第3期211-220,共10页
We are developing methods to quantify antibody interactions that include a quartz crystal microbalance (QCM) system to measure, on a molecular basis, the interaction of p53 and anti-p53 antibodies. Previously, as a mo... We are developing methods to quantify antibody interactions that include a quartz crystal microbalance (QCM) system to measure, on a molecular basis, the interaction of p53 and anti-p53 antibodies. Previously, as a model system, we developed a measurement device consisting of p53 protein (human wild type), characterized by mass spectroscopy and immobilized at various concentrations on a glass slide. The device is designed as a control to be used with immunohistochemical (IHC) assays that incorporate commercially available anti-p53 antibodies and probes. In the current study, p53 protein is covalently immobilized on a silicon dioxide-coated quartz crystal and the resonance frequency shift is followed in-situ. The functionalized sensor is then incubated with the anti-p53 antibody, which provides a direct gravimetric measure of the antibody-antigen binding. This previously described method allows the comparison of the surface immobilized protein concentrations with estimates obtained by fluorescence measurement. The p53 functionalized QCM system offers an independent measure of surface immobilized protein concentration and is essential in development of our IHC calibration prototypes. These results provide a benchmark for comparing antibody systems that may be used in developing other molecular diagnostic assays such as immunocytochemical analysis and the detection of biomarker proteins in blood and urine. 展开更多
关键词 Quartz Crystal microbalance (QCM) Antibody Characterization P53 Immobilized Protein IMMUNOCHEMISTRY Immunohistochemistry (IHC) IMMUNOCYTOCHEMISTRY
暂未订购
上一页 1 2 3 下一页 到第
使用帮助 返回顶部