This study aimed to utilize micro-computed tomography (micro-CT) analysis to compare new bone formation in rat calvarial defects using chitosan/fibroin-hydroxyapatite (CFB-HAP) or collagen (Bio-Gide) membranes. ...This study aimed to utilize micro-computed tomography (micro-CT) analysis to compare new bone formation in rat calvarial defects using chitosan/fibroin-hydroxyapatite (CFB-HAP) or collagen (Bio-Gide) membranes. Fifty-four (54) rats were studied. A circular bony defect (8 mm diameter) was formed in the centre of the calvaria using a trephine bur. The CFB-HAP membrane was prepared by thermally induced phase separation. In the experimental group (n= 18), the CFB-HAP membrane was used to cover the bony defect, and in the control group (n= 18), a resorbable collagen membrane (Bio-Gide) was used. In the negative control group (n= 18), no membrane was used. In each group, six animals were euthanized at 2, 4 and 8 weeks after surgery. The specimens were then analysed using micro-CT. There were significant differences in bone volume (BV) and bone mineral density (BMD) (P〈O.05) between the negative control group and the membrane groups. However, there were no significant differences between the CFB-HAP group and the collagen group. We concluded that the CFB-HAP membrane has significant potential as a guided bone regeneration (GBR) membrane.展开更多
We successfully obtained 3D skeletal images of Hyla suweonensis, employing a nondestructive method by applying appropriate anesthesia and limiting the radiation dose. H. suweonensis is a tree frog endemic to Korea and...We successfully obtained 3D skeletal images of Hyla suweonensis, employing a nondestructive method by applying appropriate anesthesia and limiting the radiation dose. H. suweonensis is a tree frog endemic to Korea and is on the list of endangered species. Previous studies have employed caliper-based measurements and two-dimensional (2D) X-ray imaging for anatomical analyses of the skeletal system or bone types of H. suweonensis. In this work we reconstructed three-dimensional (3D) skeletal images of H. suweonensis, utilizing a nondestructive micro-computed tomography (micro-CT) with a short scan and low radiation dose (i.e. 4 min and 0.16 Gy). Importantly, our approach can be applied to the imaging of 3D skeletal systems of other endangered frog species, allowing both versatile and high contrast images of anatomical structures without causing any significant damages to the living animal.展开更多
The structures of solid dosage forms determine their release behaviors and are critical attributes for the design and evaluation of the solid dosage forms.Here,the 3D structures of doxazosin mesylate sustained-release...The structures of solid dosage forms determine their release behaviors and are critical attributes for the design and evaluation of the solid dosage forms.Here,the 3D structures of doxazosin mesylate sustained-release tablets were parallelly assessed by micro-computed tomography(micro-CT).There were no significant differences observed in the release profiles between the RLD and the generic formulation in the conventional dissolution,but the generic preparation released slightly faster in media with ethanol during an alcohol-induced dose-dumping test.With their 3D structures obtained via micro-CT determination,the unique release behaviors of both RLD and the generic were investigated to reveal the effects of internal fine structure on the release kinetics.The structural parameters for both preparations were similar in conventional dissolution test,while the dissolutions in ethanol media showed some distinctions between RLD and generic preparations due to their static and dynamic structures.Furthermore,the findings revealed that the presence of ethanol accelerated dissolution and induced changes in internal structure of both RLD and generic preparations.Moreover,structure parameters like volume and area of outer contour,remaining solid volume and cavity volumewere not equivalent between the two formulations in 40%ethanol.In conclusion,the structure data obtained from this study provided valuable insights into the diverse release behaviors observed in various modified-release formulations in drug development and quality control.展开更多
In order to study the microstructure characteristics of normal lunate bones, eight fresh cadaver normal lunates were scanned with micro-computed tomography. High-resolution images of the micro-structure of normal luna...In order to study the microstructure characteristics of normal lunate bones, eight fresh cadaver normal lunates were scanned with micro-computed tomography. High-resolution images of the micro-structure of normal lunates were obtained and we analyzed the nutrient foramina. Then nine regions of interest(ROI) were chosen in the central sagittal plane so that we could obtain the parameters of trabecular bones of ROIs. The distal lamellar-like compact structure had statistically significant differences when it was compared with the ROIs in the volar and dorsal ends of the distal cortex. The difference of diameter between the volar and dorsal foramina was significant(P<0.05). However, there was no significant difference regarding the number. The trabecular bones of the volar and dorsal distal ends had lower intensity than those of the distal central subchondral bone plate. The diameters of the nutrient foramina on the volar cortex were larger than those on the dorsal. This research provided more detailed information about microstructure of normal lunate and the nutrient foramina on cortex, and a reference for further study about diseased lunate.展开更多
Micro-computed tomography (MCT) encompasses two primary scanning options: ex-vivo and in-vivo imaging. Ex-vivo scanning involves the examination of extracted teeth or dental specimens, allowing for detailed analyses o...Micro-computed tomography (MCT) encompasses two primary scanning options: ex-vivo and in-vivo imaging. Ex-vivo scanning involves the examination of extracted teeth or dental specimens, allowing for detailed analyses of the microarchitecture of mineralized tissue. By analyzing the microarchitecture of dental tissues, MCT can provide valuable information about bone density, porosity, and microstructural changes, contributing to a better understanding of disease progression and treatment outcomes. Moreover, MCT facilitates the quantification of dental parameters, such as bone volume, trabecular thickness, and connectivity density, which are crucial for evaluating the efficacy of dental interventions. This present study aims to comprehensively review and explore the applications of MCT in dentistry and highlight its potential in advancing research and clinical practice. The results depicted that the quantitative approach of MCT enhances the precision and reliability of dental research. Researchers and clinicians can make evidence-based decisions regarding treatment strategies and patient management, relying on quantifiable data provided by MCT. The applications of MCT in dentistry extend beyond research, with potential clinical implications in fields such as dental implantology and endodontics. MCT is expected to play an increasingly significant role in enhancing our understanding of dental pathologies, improving treatment outcomes, and ultimately, benefiting patient care in the field of dentistry.展开更多
The aim of this study was to identify three-dimensional microstructural changes of trabecular bone with age and gender, using micro-computed tomography. Human trabecular bone from two disease groups, osteoporosis and ...The aim of this study was to identify three-dimensional microstructural changes of trabecular bone with age and gender, using micro-computed tomography. Human trabecular bone from two disease groups, osteoporosis and osteoarthritis was analyzed. A prior analysis of the effects of some procedure variables on the micro-CT results was performed. Preliminary micro-CT scans were performed with three voxel resolutions and two acquisition conditions. On the reconstruction step, the image segmentation was performed with three different threshold values. Samples were collected from patients, with coxarthrosis (osteoarthritis) or fragility fracture (osteoporosis). The specimens of the coxarthrosis group include twenty females and fifteen males, while the fragility fracture group was composed by twenty three females and seven males. The mean age of the population was 69 ± 11 (females) and 67 ± 10 years (males), in the coxarthrosis group, while in the fragility fracture group was 81 ± 6 (females) and 78 ± 6 (males) years. The 30 μm voxel size provided lower percentage difference for the microarchitecture parameters. Acquisition conditions with 160 μA and 60 kV permit the evaluation of all the volume’s sample, with low average values of the coefficients of variation of the microstructural parameters. No statistically significant differences were found between the two diseases groups, neither between genders. However, with aging, there is a decrease of bone volume fraction, trabecular number and fractal dimension, and an increase of structural model index and trabecular separation, for both disease groups and genders. The parameters bone specific surface, trabecular thickness and degree of anisotropy have different behaviors with age, depending on the type of disease. While in coxarthrosis patients, trabecular thickness increases with age, in the fragility fracture group, there is a decrease of trabecular thickness with increasing age. Our findings indicate that disease, age and gender do not provide significant differences in trabecular microstructure. With aging, some parameters exhibit different trends which are possibly related to different mechanisms for different diseases.展开更多
Microstructure of shale formation is the key to understanding its petrophysical and chemical properties.Optical microscopy, scanning electron microscopy and micro-computed tomography(μ-CT) have been combined for char...Microstructure of shale formation is the key to understanding its petrophysical and chemical properties.Optical microscopy, scanning electron microscopy and micro-computed tomography(μ-CT) have been combined for characterization of microstructure of Longmaxi(LMX)shale from Shizhu area, Sichan Basin. The results indicate that laminated LMX shale consists of mineral matrix-rich layers and organic matter(OM)-rich layers at micrometer scale in two and three dimensions. Mineral matrix layers,mainly consisting of interparticle pores and intraplatelet pores, are approximately parallel to the bedding plane.Pyrite-rich layer, mainly containing intercrystalline pores,shows a strong preferred orientation parallel to the bedding plane. OM-rich layer, mainly containing OM pores, seems to be discontinuous. In addition, intercrystalline pores are enriched in some layers, while OM pores are distributed irregularly in matrix layers. This vertical heterogeneity of pore microscopic structures in LMX shale is of great importance to understand its petrophysical and chemical properties.展开更多
Porosity is a major issue in solidification processing of metallic materials.In this work,wedge die casting experiments were designed to investigate the effect of cooling rate on microporosity in an aluminum alloy A35...Porosity is a major issue in solidification processing of metallic materials.In this work,wedge die casting experiments were designed to investigate the effect of cooling rate on microporosity in an aluminum alloy A356.Microstructure information including dendrites and porosity were measured and observed by optical microscopy and X-ray micro-computed tomography(XMCT).The effects of cooling rate on secondary dendrite arm spacing(SDAS)and porosity were discussed.The relationship between SDAS and cooling rate was established and validated using a mathematical model.Three-dimensional(3-D)porosity information,including porosity percentage,pore volume,and pore number,was determined by XMCT.With the cooling rate decreasing from a lower to a higher position of the wedge die,the observed pore number decreases,the porosity percentage increases,and the equivalent pore radius increases.Sphericity of the pores was discussed as an empirical criterion to distinguish the types of porosity.For different cooling rates,the larger the equivalent pore radius is,the lower the sphericity of the pores.This research suggests that XMCT is a useful tool to provide critical 3-D porosity information for integrated computational materials engineering(ICME)design and process optimization of solidification products.展开更多
The particle morphological properties,such as sphericity,concavity and convexity,of a granular assembly significantly affect its macroscopic and microscopic compressive behaviors under isotropic loading condition.Howe...The particle morphological properties,such as sphericity,concavity and convexity,of a granular assembly significantly affect its macroscopic and microscopic compressive behaviors under isotropic loading condition.However,limited studies on investigating the microscopic behavior of the granular assembly with real particle shapes under isotropic compression were reported.In this study,X-ray computed tomography(mCT)and discrete element modeling(DEM)were utilized to investigate isotropic compression behavior of the granular assembly with regard to the particle morphological properties,such as particle sphericity,concavity and interparticle frictions.The mCT was first used to extract the particle morphological parameters and then the DEM was utilized to numerically investigate the influences of the particle morphological properties on the isotropic compression behavior.The image reconstruction from mCT images indicated that the presented particle quantification algorithm was robust,and the presented microscopic analysis via the DEM simulation demonstrated that the particle surface concavity significantly affected the isotropic compression behavior.The observations of the particle connectivity and local void ratio distribution also provided insights into the granular assembly under isotropic compression.Results found that the particle concavity and interparticle friction influenced the most of the isotropic compression behavior of the granular assemblies.展开更多
AIM: To explore the potential of contrast-enhanced computed tomography(CECT) using Exi Tron nano6000 for assessment of liver lesions in mouse models.METHODS: Three mouse models of liver lesions were used: bile duct li...AIM: To explore the potential of contrast-enhanced computed tomography(CECT) using Exi Tron nano6000 for assessment of liver lesions in mouse models.METHODS: Three mouse models of liver lesions were used: bile duct ligation(BDL),lipopolysaccharide(LPS)/D-galactosamine(D-Gal N),and alcohol.After injection with the contrast agent Exi Tron nano6000,the mice were scanned with micro-CT.Liver lesions were evaluated using CECT images,hematoxylin and eosin staining,and serum aminotransferase levels.Macrophage distribution in the injury models was shown by immunohistochemical staining of CD68.The in vitro studies measured the densities of RAW264.7 under different conditions by CECT.RESULTS: In the in vitro studies,CECT provided specific and strong contrast enhancement of liver in mice.CECT could present heterogeneous images anddensities of injured livers induced by BDL,LPS/D-Gal N,and alcohol.The liver histology and immunochemistry of CD68 demonstrated that both dilated biliary tracts and necrosis in the injured livers could lead to the heterogeneous distribution of macrophages.The in vitro study showed that the RAW264.7 cell masses had higher densities after LPS activation.CONCLUSION: Micro-CT with the contrast agent Exi Tron nano6000 is feasible for detecting various liver lesions by emphasizing the heterogeneous textures and densities of CECT images.展开更多
The aim of this study was to determine whether contrast-enhanced micro-computed tomography can be used for non-invasive imaging of the early-stage changes in the vasculature of tumours that have been treated with phot...The aim of this study was to determine whether contrast-enhanced micro-computed tomography can be used for non-invasive imaging of the early-stage changes in the vasculature of tumours that have been treated with photodynamic therapy (PDT). The subjects used were C3H mice with an RIF-1 tumour implanted subcutaneously and allowed to grow for 3 weeks prior to treatment. The experimental groups were PDT-treated (150 J/cm2 and 50 J/cm2) and control (150 J/cm2 light-only and untreated). The laser light exposure was performed at 15 - 30 minutes after the administration of the photosensitizer (BPD-MA). The contrast-enhanced micro-computed tomography imaging procedure consisted of eight-second scans taking place before treatment and up to 24 hours after treatment. The 150 J/cm2 PDT group showed a significant increase in the ratio of blood volume to tumour volume at 2, 8 and 24 hours after treatment when compared to pre-treatment measurements (p 2 PDT group at 24 hours after treatment. This preliminary study indicates that micro-CT can detect compromised vasculature in tumours treated with high-fluence photodynamic therapy as early as 2 hours post treatment.展开更多
An aluminum matrix syntactic foam, incorporated with hollow-structured fly ash particles, was fabricated by pressure infiltration technique. X-ray micro-computed tomography was used to characterize its heterogeneous m...An aluminum matrix syntactic foam, incorporated with hollow-structured fly ash particles, was fabricated by pressure infiltration technique. X-ray micro-computed tomography was used to characterize its heterogeneous microstructure three dimensionally (3D). The quantification of some microstructure features, such as content and size distribution of hollow fly ash particles, was acquired in 3D. The tomographic data were exploited as a rapid method to generate a microstructurally accurate and robust 3D meshed model. The thermal transport behavior has been modeled using a commercial finite-element code to conduct steady state analyses. Simulation of the thermal conductivity showed good correlation with experimental result.展开更多
Quantitative analysis on cutting notch of tea stalk is one method to better understand shear resistance and mechanical properties of the stalk,which could improve cutting performance and efficiency for tea harvesting....Quantitative analysis on cutting notch of tea stalk is one method to better understand shear resistance and mechanical properties of the stalk,which could improve cutting performance and efficiency for tea harvesting.Optimal design of the cutter might be achieved through structural analysis of cutting notch by X-ray micro-computed tomography(micro-CT).The third inter-node of the stalks were sampled and scanned by micro-CT after they were cut at different cutting depths(0.7,1.5,2.3 mm)and cutting edge angles of cutter(30,35,40).The structural change of the cutting notch and cutting force was observed.Grey-scale histogram analysis and bimodal segmentation method were used to extract the information about cutting notch from 2D slice images.A 3D model of the stalk was established with reconstruction and volume rendering.Besides,maximum crosssectional area ratio of cutting notch(MCSARCN)and volume ratio of cutting notch(VRCN)were calculated.The results show that MCSARCN and VRCN had a closely relationship with the cutting force,cutting depth and cutting edge angle according to 3D tomographic images and 2D slice images.Both MCSARCN and VRCN increased with cutting depth,despite of cutting edge angle.For cutting edge angle of 30,35and 40at different cutting depths,MCSARCN increased from 4.89%to 9.47%,from 8.51%to 22.83%and from 4.30%to 16.87%,respectively.Meanwhile,VRCN increased from 1.59%to 2.13%,from 2.98%to 5.76%and from 3.04%to 5.01%,respectively.When cutting depth was 1.5 mm,cutting force increased but VRCN present a decreased trend with cutting edge angle.X-ray micro-CT could be used to analyze the structure on cutting notch of tea stalks which is helpful in optimizing the structural parameters of the cutter.展开更多
Background Osteoporosis (OP) is a common bone disease,which adversely affects life quality.Effective treatments are necessary to combat both the loss and fracture of bone.Recent studies indicated that caffeic acid p...Background Osteoporosis (OP) is a common bone disease,which adversely affects life quality.Effective treatments are necessary to combat both the loss and fracture of bone.Recent studies indicated that caffeic acid phenethyl ester (CAPE) is a natural chemical compound from honeybee propolis which is capable of attenuating osteoclastogenesis and bone resorption.Therefore,this study aimed to investigate the effect of CAPE on bone loss in OP mice using micro-computed tomography (CT) and histology.Methods Eighteen mice were prepared and evenly divided into three groups.The six mice in the sham+PBS group did not undergo ovariectomy and were intraperitoneally injected with PBS during the curing period.Twelve mice were ovariectomized (OVX) to induce OP.Six of them in the OVX+CAPE group were intraperitoneally injected with 0.5 mg/kg CAPE twice per week for 4 weeks after ovariectomy.The other six OVX mice in OVX+PBS group were treated with PBS.All the mice were sacrificed 4 weeks after ovariectomy.The tibias were bilaterally excised for micro-CT scan and histological analysis.The Mann-Whitney U test was used to test the statistical differences among groups.Results Bone loss occurred in OVX mice.Compared with the sham+PBS group,mice in the OVX+PBS group exhibited a significant decrease in bone mineral density (BMD,P <0.05),bone volume fraction (BV/TV,P <0.01),trabecular thickness (Tb.Th,P <0.05),and trabecular number (Tb.N,P <0.01),as well as a non-insignificant increase in the number of osteoclasts (N.Oc/B.Pm).With CAPE treatment,the microarchitecture of the tibial metaphyses was significantly improved with a reduction of osteoclast formation.Compared with the OVX+PBS group,BV/TV in the OVX+CAPE group was significantly increased by 33.9% (P <0.05).Conclusion CAPE therapy results in the protection of bone loss induced by OVX.展开更多
In line X-ray phase contrast micro-computed tomography (IL-XPCT), which can be implemented at third generation synchrotron radiation sources or by using a micro-focus X-ray tube, is a powerful technique for non-dest...In line X-ray phase contrast micro-computed tomography (IL-XPCT), which can be implemented at third generation synchrotron radiation sources or by using a micro-focus X-ray tube, is a powerful technique for non-destructive, high-resolution investigations of a broad variety of materials. At the Shanghai Synchrotron Radiation Facility (SSRF), the X-ray Imaging and Biomedical Applications Beamline was built and started regular user operation in May 2009. Both qualitative (without phase retrieval) and quantitative (with phase retrieval) three-dimensional IL-XPCT experimental techniques have been established at the beamline IL-XPCT experiments of a test sample (plastic pipes) used to evaluate the technique, and of a biological sample (locust) at the beamline are reported. Two series of images, qualitative and quantitative, including tomographic slices and three-dimensional rendering images were obtained. In qualitative images, there is a strong edge-enhancement which leads to very clear sample contours, while in quantitative images, the edge-enhancement fades but quantitative measurement of sample's phase information could be achieved. The experiments demonstrate that the combination of qualitative and quantitative images is useful for biological sample studies.展开更多
The engineering of biochars with desired morphologies and pore structures is a far-reaching objective towards sustainable pore-dependent environmental technologies,such as water and soil remediation or catalysis.We he...The engineering of biochars with desired morphologies and pore structures is a far-reaching objective towards sustainable pore-dependent environmental technologies,such as water and soil remediation or catalysis.We hereby report a series of experiments that allow the direct following of the shape and porosity of single biochar particles during pyrolysis.Particles~1-2 mm in diameter of unwashed and water-washed raw walnut shells were continuously 3D imaged during pyrolysis to 575℃at a 10 K min^(−1) in Ar to obtain time-and temperature-resolved x-ray micro computed tomographies to a 0.82μm resolution.Results showed visual evidence of a 30%and 70%v/v particle shrinkage for unwashed and washed samples,respectively.Particle swelling between 200 and 300℃in the unwashed sample provided evidence of the softening of native biopolymers associated with lignin in untreated biomass.A purpose-defined parameterΛshows the temperature-dependence of pore re-distribution towards the center of the particle to be linear for both samples.Λwas found to be 3.2×10^(−4)K^(−1) in the washed sample,approximately 3.5 times faster than in the unwashed one.Such linear dependence is significantly slower than an exponential Arrhenius-like trend thereby providing a qualitative measure of the heat and mass transport phenomena limiting the chemical reactions in the porous medium.This evidence is key to resolving the pathways to the thermochemical decomposition of biomass leading to preparation of precision-engineered biochars.展开更多
The computed tomography imaging of a local region inside a sample with a size larger than the field of view is particularly important for synchrotron X-ray imaging.In this letter,an improved algorithm is proposed to r...The computed tomography imaging of a local region inside a sample with a size larger than the field of view is particularly important for synchrotron X-ray imaging.In this letter,an improved algorithm is proposed to reconstruct the local structure inside a sample using almost completely local data.The algorithm significantly reduces the X-ray radiation dose and improves computational efficiency.Simulation results show that the new algorithm works well and has a higher reconstruction precision than previous methods,as confirmed by experimental results carried out at the Shanghai Synchrotron Radiation Facility.展开更多
BACKGROUND Early screening,preoperative staging,and diagnosis of lymph node metastasis are crucial for improving the prognosis of gastric cancer(GC).AIM To evaluate the diagnostic value of combined multidetector compu...BACKGROUND Early screening,preoperative staging,and diagnosis of lymph node metastasis are crucial for improving the prognosis of gastric cancer(GC).AIM To evaluate the diagnostic value of combined multidetector computed tomography(MDCT)and gastrointestinal endoscopy for GC screening,preoperative staging,and lymph node metastasis detection,thereby providing a reference for clinical diagnosis and treatment.METHODS In this retrospective study clinical and imaging data of 134 patients with suspected GC who were admitted between January 2023 and October 2024 were initially reviewed.According to the inclusion and exclusion criteria,102 patients were finally enrolled in the analysis.All enrolled patients had undergone both MDCT and gastrointestinal endoscopy examinations prior to surgical intervention.Preoperative clinical staging and lymph node metastasis findings were compared with pathological results.RESULTS The combined use of MDCT and gastrointestinal endoscopy demonstrated a sensitivity of 98.53%,specificity of 97.06%,accuracy of 98.04%,positive predictive value of 98.53%,and negative predictive value of 97.06%for diagnosing GC.These factors were all significantly higher than those of MDCT or endoscopy alone(P<0.05).The accuracy rates of the combined approach for detecting clinical T and N stages were 97.06%and 92.65%,respectively,outperforming MDCT alone(86.76% and 79.41%)and endoscopy alone(85.29% and 70.59%)(P<0.05).Among 68 patients with confirmed GC,50(73.53%)were pathologically diagnosed with lymph node metastasis.The accuracy for detecting lymph node metastasis was 66.00%with endoscopy,76.00%with MDCT,and 92.00% with the combined approach,all with statistically significant differences(P<0.05).CONCLUSION The combined application of MDCT and gastrointestinal endoscopy enhanced diagnostic accuracy for GC,provided greater consistency in preoperative staging,and improved the detection of lymph node metastasis,thereby demonstrating significant clinical utility.展开更多
AIM:To investigate the effects of chronic alcohol consumption on retinal microcirculation by comparing different alcohol-consuming groups using optical coherence tomography(OCT)and OCT angiography(OCTA).METHODS:This o...AIM:To investigate the effects of chronic alcohol consumption on retinal microcirculation by comparing different alcohol-consuming groups using optical coherence tomography(OCT)and OCT angiography(OCTA).METHODS:This observational clinical study utilized a cross-sectional and prospective design,focusing on chronic alcohol consumers alongside a non-consuming control group.OCT/OCTA imaging parameters including central retinal subfield thickness(CST),subfoveal choroidal thickness(SCT),foveal avascular zone(FAZ)and vessel density(VD)in the superficial and deep capillary plexuses in both the macular and optic disc(OD)regions were recorded.Data were analyzed using SPSS 15.0;descriptive statistics were reported,group comparisons were performed with Chisquare,Kruskal–Wallis,and Bonferroni-corrected Mann–Whitney U tests,and relationships were assessed using Spearman correlation,with statistical significance set at P<0.05.RESULTS:A total of 160 eyes of 160 participants(110 females and 50 males with mean age 38.7±9.9y)who don’t smoke were divided into five groups:never,occasional,monthly,weekly and daily drinkers.The mean CST was 216.6±14.2μm and the mean SCT was 358.9±84.5μm.There was no statistically significantly difference in CST and SCT among the groups(P=0.890,0.799).Foveal superficial capillary plexuses(SCPs)VD was higher in monthly drinkers compared to occasional drinkers(P=0.015).Foveal VD in deep capillary plexus was also higher in monthly drinkers than in never and occasional drinkers(P=0.004,0.006).Nasal SCPs VD at the OD was higher in monthly drinkers compared to never drinkers(P=0.005).There was no significant difference FAZ area among the groups(P=0.071).CONCLUSION:Both superficial and deep microvascular structures in the inferior quadrants of macula are positively correlated with frequency of alcohol use.Also in our study results is that the monthly drinker group has uniquely higher VDs in both macula and OD.This leads us to consider moderate alcohol consumption may also have protective effects on retinal microcirculation.展开更多
Although previous studies have demonstrated that transcranial focused ultrasound stimulation protects the ischemic brain,clear criteria for the stimulation time window and intensity are lacking.Electrical impedance to...Although previous studies have demonstrated that transcranial focused ultrasound stimulation protects the ischemic brain,clear criteria for the stimulation time window and intensity are lacking.Electrical impedance tomography enables real-time monitoring of changes in cerebral blood perfusion within the ischemic brain,but investigating the feasibility of using this method to assess post-stroke rehabilitation in vivo remains critical.In this study,ischemic stroke was induced in rats through middle cerebral artery occlusion surgery.Transcranial focused ultrasound stimulation was used to treat the rat model of ischemia,and electrical impedance tomography was used to measure impedance during both the acute stage of ischemia and the rehabilitation stage following the stimulation.Electrical impedance tomography results indicated that cerebral impedance increased after the onset of ischemia and decreased following transcranial focused ultrasound stimulation.Furthermore,the stimulation promoted motor function recovery,reduced cerebral infarction volume in the rat model of ischemic stroke,and induced the expression of brain-derived neurotrophic factor in the ischemic brain.Our results also revealed a significant correlation between the impedance of the ischemic brain post-intervention and improvements in behavioral scores and infarct volume.This study shows that daily administration of transcranial focused ultrasound stimulation for 20 minutes to the ischemic hemisphere 24 hours after cerebral ischemia enhanced motor recovery in a rat model of ischemia.Additionally,our findings indicate that electrical impedance tomography can serve as a valuable tool for quantitatively evaluating rehabilitation after ischemic stroke in vivo.These findings suggest the feasibility of using impedance data collected via electrical impedance tomography to clinically assess the effects of rehabilitatory interventions for patients with ischemic stroke.展开更多
文摘This study aimed to utilize micro-computed tomography (micro-CT) analysis to compare new bone formation in rat calvarial defects using chitosan/fibroin-hydroxyapatite (CFB-HAP) or collagen (Bio-Gide) membranes. Fifty-four (54) rats were studied. A circular bony defect (8 mm diameter) was formed in the centre of the calvaria using a trephine bur. The CFB-HAP membrane was prepared by thermally induced phase separation. In the experimental group (n= 18), the CFB-HAP membrane was used to cover the bony defect, and in the control group (n= 18), a resorbable collagen membrane (Bio-Gide) was used. In the negative control group (n= 18), no membrane was used. In each group, six animals were euthanized at 2, 4 and 8 weeks after surgery. The specimens were then analysed using micro-CT. There were significant differences in bone volume (BV) and bone mineral density (BMD) (P〈O.05) between the negative control group and the membrane groups. However, there were no significant differences between the CFB-HAP group and the collagen group. We concluded that the CFB-HAP membrane has significant potential as a guided bone regeneration (GBR) membrane.
基金supported by Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Science, ICT and Future Planning (grant numbers: NRF-2015R1C1A1A01052498 and NRF2014R1A1A1006010)
文摘We successfully obtained 3D skeletal images of Hyla suweonensis, employing a nondestructive method by applying appropriate anesthesia and limiting the radiation dose. H. suweonensis is a tree frog endemic to Korea and is on the list of endangered species. Previous studies have employed caliper-based measurements and two-dimensional (2D) X-ray imaging for anatomical analyses of the skeletal system or bone types of H. suweonensis. In this work we reconstructed three-dimensional (3D) skeletal images of H. suweonensis, utilizing a nondestructive micro-computed tomography (micro-CT) with a short scan and low radiation dose (i.e. 4 min and 0.16 Gy). Importantly, our approach can be applied to the imaging of 3D skeletal systems of other endangered frog species, allowing both versatile and high contrast images of anatomical structures without causing any significant damages to the living animal.
基金This work was supported by the Key Programfor International Science and Technology Cooperation Projects of China(2020YFE0201700)State Drug Administration key laboratory project(2024HYZX04).
文摘The structures of solid dosage forms determine their release behaviors and are critical attributes for the design and evaluation of the solid dosage forms.Here,the 3D structures of doxazosin mesylate sustained-release tablets were parallelly assessed by micro-computed tomography(micro-CT).There were no significant differences observed in the release profiles between the RLD and the generic formulation in the conventional dissolution,but the generic preparation released slightly faster in media with ethanol during an alcohol-induced dose-dumping test.With their 3D structures obtained via micro-CT determination,the unique release behaviors of both RLD and the generic were investigated to reveal the effects of internal fine structure on the release kinetics.The structural parameters for both preparations were similar in conventional dissolution test,while the dissolutions in ethanol media showed some distinctions between RLD and generic preparations due to their static and dynamic structures.Furthermore,the findings revealed that the presence of ethanol accelerated dissolution and induced changes in internal structure of both RLD and generic preparations.Moreover,structure parameters like volume and area of outer contour,remaining solid volume and cavity volumewere not equivalent between the two formulations in 40%ethanol.In conclusion,the structure data obtained from this study provided valuable insights into the diverse release behaviors observed in various modified-release formulations in drug development and quality control.
文摘In order to study the microstructure characteristics of normal lunate bones, eight fresh cadaver normal lunates were scanned with micro-computed tomography. High-resolution images of the micro-structure of normal lunates were obtained and we analyzed the nutrient foramina. Then nine regions of interest(ROI) were chosen in the central sagittal plane so that we could obtain the parameters of trabecular bones of ROIs. The distal lamellar-like compact structure had statistically significant differences when it was compared with the ROIs in the volar and dorsal ends of the distal cortex. The difference of diameter between the volar and dorsal foramina was significant(P<0.05). However, there was no significant difference regarding the number. The trabecular bones of the volar and dorsal distal ends had lower intensity than those of the distal central subchondral bone plate. The diameters of the nutrient foramina on the volar cortex were larger than those on the dorsal. This research provided more detailed information about microstructure of normal lunate and the nutrient foramina on cortex, and a reference for further study about diseased lunate.
文摘Micro-computed tomography (MCT) encompasses two primary scanning options: ex-vivo and in-vivo imaging. Ex-vivo scanning involves the examination of extracted teeth or dental specimens, allowing for detailed analyses of the microarchitecture of mineralized tissue. By analyzing the microarchitecture of dental tissues, MCT can provide valuable information about bone density, porosity, and microstructural changes, contributing to a better understanding of disease progression and treatment outcomes. Moreover, MCT facilitates the quantification of dental parameters, such as bone volume, trabecular thickness, and connectivity density, which are crucial for evaluating the efficacy of dental interventions. This present study aims to comprehensively review and explore the applications of MCT in dentistry and highlight its potential in advancing research and clinical practice. The results depicted that the quantitative approach of MCT enhances the precision and reliability of dental research. Researchers and clinicians can make evidence-based decisions regarding treatment strategies and patient management, relying on quantifiable data provided by MCT. The applications of MCT in dentistry extend beyond research, with potential clinical implications in fields such as dental implantology and endodontics. MCT is expected to play an increasingly significant role in enhancing our understanding of dental pathologies, improving treatment outcomes, and ultimately, benefiting patient care in the field of dentistry.
基金the Portuguese research foundation FCT(Fundacao para a Ciencia e Tecnologia)for providing financial support(SFRH/BD/48100/2008)MFC Pereira and A Mauricio acknowledge FEDER Funds through Programa Operacional Factores de Com-petitividade-COMPETE,and FCT Project PEst-OE/CTE/UI0098/2011
文摘The aim of this study was to identify three-dimensional microstructural changes of trabecular bone with age and gender, using micro-computed tomography. Human trabecular bone from two disease groups, osteoporosis and osteoarthritis was analyzed. A prior analysis of the effects of some procedure variables on the micro-CT results was performed. Preliminary micro-CT scans were performed with three voxel resolutions and two acquisition conditions. On the reconstruction step, the image segmentation was performed with three different threshold values. Samples were collected from patients, with coxarthrosis (osteoarthritis) or fragility fracture (osteoporosis). The specimens of the coxarthrosis group include twenty females and fifteen males, while the fragility fracture group was composed by twenty three females and seven males. The mean age of the population was 69 ± 11 (females) and 67 ± 10 years (males), in the coxarthrosis group, while in the fragility fracture group was 81 ± 6 (females) and 78 ± 6 (males) years. The 30 μm voxel size provided lower percentage difference for the microarchitecture parameters. Acquisition conditions with 160 μA and 60 kV permit the evaluation of all the volume’s sample, with low average values of the coefficients of variation of the microstructural parameters. No statistically significant differences were found between the two diseases groups, neither between genders. However, with aging, there is a decrease of bone volume fraction, trabecular number and fractal dimension, and an increase of structural model index and trabecular separation, for both disease groups and genders. The parameters bone specific surface, trabecular thickness and degree of anisotropy have different behaviors with age, depending on the type of disease. While in coxarthrosis patients, trabecular thickness increases with age, in the fragility fracture group, there is a decrease of trabecular thickness with increasing age. Our findings indicate that disease, age and gender do not provide significant differences in trabecular microstructure. With aging, some parameters exhibit different trends which are possibly related to different mechanisms for different diseases.
基金supported by the Strategic Priority Research Program of the Chinese Academy of Sciences(No.XDB1002010)the Major Program for the Fundamental Research of Shanghai Committee of Science and Technology(No.12JC1410400)the National Natural Science Foundation of China for Distinguished Young Scholars(No.41325016)
文摘Microstructure of shale formation is the key to understanding its petrophysical and chemical properties.Optical microscopy, scanning electron microscopy and micro-computed tomography(μ-CT) have been combined for characterization of microstructure of Longmaxi(LMX)shale from Shizhu area, Sichan Basin. The results indicate that laminated LMX shale consists of mineral matrix-rich layers and organic matter(OM)-rich layers at micrometer scale in two and three dimensions. Mineral matrix layers,mainly consisting of interparticle pores and intraplatelet pores, are approximately parallel to the bedding plane.Pyrite-rich layer, mainly containing intercrystalline pores,shows a strong preferred orientation parallel to the bedding plane. OM-rich layer, mainly containing OM pores, seems to be discontinuous. In addition, intercrystalline pores are enriched in some layers, while OM pores are distributed irregularly in matrix layers. This vertical heterogeneity of pore microscopic structures in LMX shale is of great importance to understand its petrophysical and chemical properties.
文摘Porosity is a major issue in solidification processing of metallic materials.In this work,wedge die casting experiments were designed to investigate the effect of cooling rate on microporosity in an aluminum alloy A356.Microstructure information including dendrites and porosity were measured and observed by optical microscopy and X-ray micro-computed tomography(XMCT).The effects of cooling rate on secondary dendrite arm spacing(SDAS)and porosity were discussed.The relationship between SDAS and cooling rate was established and validated using a mathematical model.Three-dimensional(3-D)porosity information,including porosity percentage,pore volume,and pore number,was determined by XMCT.With the cooling rate decreasing from a lower to a higher position of the wedge die,the observed pore number decreases,the porosity percentage increases,and the equivalent pore radius increases.Sphericity of the pores was discussed as an empirical criterion to distinguish the types of porosity.For different cooling rates,the larger the equivalent pore radius is,the lower the sphericity of the pores.This research suggests that XMCT is a useful tool to provide critical 3-D porosity information for integrated computational materials engineering(ICME)design and process optimization of solidification products.
基金the Universidad Nacional de San Agustín(UNSA)through the joint Center for Mining Sustainability with the Colorado School of Mines is highly acknowledged.
文摘The particle morphological properties,such as sphericity,concavity and convexity,of a granular assembly significantly affect its macroscopic and microscopic compressive behaviors under isotropic loading condition.However,limited studies on investigating the microscopic behavior of the granular assembly with real particle shapes under isotropic compression were reported.In this study,X-ray computed tomography(mCT)and discrete element modeling(DEM)were utilized to investigate isotropic compression behavior of the granular assembly with regard to the particle morphological properties,such as particle sphericity,concavity and interparticle frictions.The mCT was first used to extract the particle morphological parameters and then the DEM was utilized to numerically investigate the influences of the particle morphological properties on the isotropic compression behavior.The image reconstruction from mCT images indicated that the presented particle quantification algorithm was robust,and the presented microscopic analysis via the DEM simulation demonstrated that the particle surface concavity significantly affected the isotropic compression behavior.The observations of the particle connectivity and local void ratio distribution also provided insights into the granular assembly under isotropic compression.Results found that the particle concavity and interparticle friction influenced the most of the isotropic compression behavior of the granular assemblies.
基金Supported by National Natural Science Fund,No.81270558
文摘AIM: To explore the potential of contrast-enhanced computed tomography(CECT) using Exi Tron nano6000 for assessment of liver lesions in mouse models.METHODS: Three mouse models of liver lesions were used: bile duct ligation(BDL),lipopolysaccharide(LPS)/D-galactosamine(D-Gal N),and alcohol.After injection with the contrast agent Exi Tron nano6000,the mice were scanned with micro-CT.Liver lesions were evaluated using CECT images,hematoxylin and eosin staining,and serum aminotransferase levels.Macrophage distribution in the injury models was shown by immunohistochemical staining of CD68.The in vitro studies measured the densities of RAW264.7 under different conditions by CECT.RESULTS: In the in vitro studies,CECT provided specific and strong contrast enhancement of liver in mice.CECT could present heterogeneous images anddensities of injured livers induced by BDL,LPS/D-Gal N,and alcohol.The liver histology and immunochemistry of CD68 demonstrated that both dilated biliary tracts and necrosis in the injured livers could lead to the heterogeneous distribution of macrophages.The in vitro study showed that the RAW264.7 cell masses had higher densities after LPS activation.CONCLUSION: Micro-CT with the contrast agent Exi Tron nano6000 is feasible for detecting various liver lesions by emphasizing the heterogeneous textures and densities of CECT images.
文摘The aim of this study was to determine whether contrast-enhanced micro-computed tomography can be used for non-invasive imaging of the early-stage changes in the vasculature of tumours that have been treated with photodynamic therapy (PDT). The subjects used were C3H mice with an RIF-1 tumour implanted subcutaneously and allowed to grow for 3 weeks prior to treatment. The experimental groups were PDT-treated (150 J/cm2 and 50 J/cm2) and control (150 J/cm2 light-only and untreated). The laser light exposure was performed at 15 - 30 minutes after the administration of the photosensitizer (BPD-MA). The contrast-enhanced micro-computed tomography imaging procedure consisted of eight-second scans taking place before treatment and up to 24 hours after treatment. The 150 J/cm2 PDT group showed a significant increase in the ratio of blood volume to tumour volume at 2, 8 and 24 hours after treatment when compared to pre-treatment measurements (p 2 PDT group at 24 hours after treatment. This preliminary study indicates that micro-CT can detect compromised vasculature in tumours treated with high-fluence photodynamic therapy as early as 2 hours post treatment.
基金Funded by the National Natural Science Foundation of China (No. 51001037)the Fundamental Research Funds for the Central Universities (No. HIT.NSRIF.2013003)
文摘An aluminum matrix syntactic foam, incorporated with hollow-structured fly ash particles, was fabricated by pressure infiltration technique. X-ray micro-computed tomography was used to characterize its heterogeneous microstructure three dimensionally (3D). The quantification of some microstructure features, such as content and size distribution of hollow fly ash particles, was acquired in 3D. The tomographic data were exploited as a rapid method to generate a microstructurally accurate and robust 3D meshed model. The thermal transport behavior has been modeled using a commercial finite-element code to conduct steady state analyses. Simulation of the thermal conductivity showed good correlation with experimental result.
基金The authors acknowledge Eric R.Kent and Jizhang Wang for assistance with editing the manuscript.This work was supported by Six Talent Peaks Program in Jiangsu Province(2015-ZBZZ-021)Key R&D Program of Jiangsu Province(BE2016354)Priority Academic Program Development of Jiangsu Higher Education Institutions.
文摘Quantitative analysis on cutting notch of tea stalk is one method to better understand shear resistance and mechanical properties of the stalk,which could improve cutting performance and efficiency for tea harvesting.Optimal design of the cutter might be achieved through structural analysis of cutting notch by X-ray micro-computed tomography(micro-CT).The third inter-node of the stalks were sampled and scanned by micro-CT after they were cut at different cutting depths(0.7,1.5,2.3 mm)and cutting edge angles of cutter(30,35,40).The structural change of the cutting notch and cutting force was observed.Grey-scale histogram analysis and bimodal segmentation method were used to extract the information about cutting notch from 2D slice images.A 3D model of the stalk was established with reconstruction and volume rendering.Besides,maximum crosssectional area ratio of cutting notch(MCSARCN)and volume ratio of cutting notch(VRCN)were calculated.The results show that MCSARCN and VRCN had a closely relationship with the cutting force,cutting depth and cutting edge angle according to 3D tomographic images and 2D slice images.Both MCSARCN and VRCN increased with cutting depth,despite of cutting edge angle.For cutting edge angle of 30,35and 40at different cutting depths,MCSARCN increased from 4.89%to 9.47%,from 8.51%to 22.83%and from 4.30%to 16.87%,respectively.Meanwhile,VRCN increased from 1.59%to 2.13%,from 2.98%to 5.76%and from 3.04%to 5.01%,respectively.When cutting depth was 1.5 mm,cutting force increased but VRCN present a decreased trend with cutting edge angle.X-ray micro-CT could be used to analyze the structure on cutting notch of tea stalks which is helpful in optimizing the structural parameters of the cutter.
基金This study was partially supported by an Endeavour Research Fellowship Award awarded to Dr. Wang Qing, and grants from National Natural Science Foundation of China (No. 31340010 and No. 31271033), Science Foundation of Ministry of Education of China (No. 20121417120004), Natural Science Foundation of Shanxi Province (No. 2013021036-3), and Special Funds for Talent Introduction in Guang Dong Universities.
文摘Background Osteoporosis (OP) is a common bone disease,which adversely affects life quality.Effective treatments are necessary to combat both the loss and fracture of bone.Recent studies indicated that caffeic acid phenethyl ester (CAPE) is a natural chemical compound from honeybee propolis which is capable of attenuating osteoclastogenesis and bone resorption.Therefore,this study aimed to investigate the effect of CAPE on bone loss in OP mice using micro-computed tomography (CT) and histology.Methods Eighteen mice were prepared and evenly divided into three groups.The six mice in the sham+PBS group did not undergo ovariectomy and were intraperitoneally injected with PBS during the curing period.Twelve mice were ovariectomized (OVX) to induce OP.Six of them in the OVX+CAPE group were intraperitoneally injected with 0.5 mg/kg CAPE twice per week for 4 weeks after ovariectomy.The other six OVX mice in OVX+PBS group were treated with PBS.All the mice were sacrificed 4 weeks after ovariectomy.The tibias were bilaterally excised for micro-CT scan and histological analysis.The Mann-Whitney U test was used to test the statistical differences among groups.Results Bone loss occurred in OVX mice.Compared with the sham+PBS group,mice in the OVX+PBS group exhibited a significant decrease in bone mineral density (BMD,P <0.05),bone volume fraction (BV/TV,P <0.01),trabecular thickness (Tb.Th,P <0.05),and trabecular number (Tb.N,P <0.01),as well as a non-insignificant increase in the number of osteoclasts (N.Oc/B.Pm).With CAPE treatment,the microarchitecture of the tibial metaphyses was significantly improved with a reduction of osteoclast formation.Compared with the OVX+PBS group,BV/TV in the OVX+CAPE group was significantly increased by 33.9% (P <0.05).Conclusion CAPE therapy results in the protection of bone loss induced by OVX.
基金Supported by the Major Research Plan of the National Natural Science Foundation of China (No.2010CB834301)the National Natural Science Foundation of China (Nos.10805071 and 10705020)+2 种基金the Chinese Academy of Sciences Key Project of International Co-operation (No.GJHZ09058)the Shanghai Key Project of Basic Research (No.08JC1411900)supported by ICTP TRIL Programme
文摘In line X-ray phase contrast micro-computed tomography (IL-XPCT), which can be implemented at third generation synchrotron radiation sources or by using a micro-focus X-ray tube, is a powerful technique for non-destructive, high-resolution investigations of a broad variety of materials. At the Shanghai Synchrotron Radiation Facility (SSRF), the X-ray Imaging and Biomedical Applications Beamline was built and started regular user operation in May 2009. Both qualitative (without phase retrieval) and quantitative (with phase retrieval) three-dimensional IL-XPCT experimental techniques have been established at the beamline IL-XPCT experiments of a test sample (plastic pipes) used to evaluate the technique, and of a biological sample (locust) at the beamline are reported. Two series of images, qualitative and quantitative, including tomographic slices and three-dimensional rendering images were obtained. In qualitative images, there is a strong edge-enhancement which leads to very clear sample contours, while in quantitative images, the edge-enhancement fades but quantitative measurement of sample's phase information could be achieved. The experiments demonstrate that the combination of qualitative and quantitative images is useful for biological sample studies.
文摘The engineering of biochars with desired morphologies and pore structures is a far-reaching objective towards sustainable pore-dependent environmental technologies,such as water and soil remediation or catalysis.We hereby report a series of experiments that allow the direct following of the shape and porosity of single biochar particles during pyrolysis.Particles~1-2 mm in diameter of unwashed and water-washed raw walnut shells were continuously 3D imaged during pyrolysis to 575℃at a 10 K min^(−1) in Ar to obtain time-and temperature-resolved x-ray micro computed tomographies to a 0.82μm resolution.Results showed visual evidence of a 30%and 70%v/v particle shrinkage for unwashed and washed samples,respectively.Particle swelling between 200 and 300℃in the unwashed sample provided evidence of the softening of native biopolymers associated with lignin in untreated biomass.A purpose-defined parameterΛshows the temperature-dependence of pore re-distribution towards the center of the particle to be linear for both samples.Λwas found to be 3.2×10^(−4)K^(−1) in the washed sample,approximately 3.5 times faster than in the unwashed one.Such linear dependence is significantly slower than an exponential Arrhenius-like trend thereby providing a qualitative measure of the heat and mass transport phenomena limiting the chemical reactions in the porous medium.This evidence is key to resolving the pathways to the thermochemical decomposition of biomass leading to preparation of precision-engineered biochars.
基金supported by the National Basic Research Program of China(No.2010CB834301)the National Natural Science Foundation of China(No.U1232205 and 11105213)the CAS-CSIRO cooperation research project(No.GJHZ1303)
文摘The computed tomography imaging of a local region inside a sample with a size larger than the field of view is particularly important for synchrotron X-ray imaging.In this letter,an improved algorithm is proposed to reconstruct the local structure inside a sample using almost completely local data.The algorithm significantly reduces the X-ray radiation dose and improves computational efficiency.Simulation results show that the new algorithm works well and has a higher reconstruction precision than previous methods,as confirmed by experimental results carried out at the Shanghai Synchrotron Radiation Facility.
文摘BACKGROUND Early screening,preoperative staging,and diagnosis of lymph node metastasis are crucial for improving the prognosis of gastric cancer(GC).AIM To evaluate the diagnostic value of combined multidetector computed tomography(MDCT)and gastrointestinal endoscopy for GC screening,preoperative staging,and lymph node metastasis detection,thereby providing a reference for clinical diagnosis and treatment.METHODS In this retrospective study clinical and imaging data of 134 patients with suspected GC who were admitted between January 2023 and October 2024 were initially reviewed.According to the inclusion and exclusion criteria,102 patients were finally enrolled in the analysis.All enrolled patients had undergone both MDCT and gastrointestinal endoscopy examinations prior to surgical intervention.Preoperative clinical staging and lymph node metastasis findings were compared with pathological results.RESULTS The combined use of MDCT and gastrointestinal endoscopy demonstrated a sensitivity of 98.53%,specificity of 97.06%,accuracy of 98.04%,positive predictive value of 98.53%,and negative predictive value of 97.06%for diagnosing GC.These factors were all significantly higher than those of MDCT or endoscopy alone(P<0.05).The accuracy rates of the combined approach for detecting clinical T and N stages were 97.06%and 92.65%,respectively,outperforming MDCT alone(86.76% and 79.41%)and endoscopy alone(85.29% and 70.59%)(P<0.05).Among 68 patients with confirmed GC,50(73.53%)were pathologically diagnosed with lymph node metastasis.The accuracy for detecting lymph node metastasis was 66.00%with endoscopy,76.00%with MDCT,and 92.00% with the combined approach,all with statistically significant differences(P<0.05).CONCLUSION The combined application of MDCT and gastrointestinal endoscopy enhanced diagnostic accuracy for GC,provided greater consistency in preoperative staging,and improved the detection of lymph node metastasis,thereby demonstrating significant clinical utility.
文摘AIM:To investigate the effects of chronic alcohol consumption on retinal microcirculation by comparing different alcohol-consuming groups using optical coherence tomography(OCT)and OCT angiography(OCTA).METHODS:This observational clinical study utilized a cross-sectional and prospective design,focusing on chronic alcohol consumers alongside a non-consuming control group.OCT/OCTA imaging parameters including central retinal subfield thickness(CST),subfoveal choroidal thickness(SCT),foveal avascular zone(FAZ)and vessel density(VD)in the superficial and deep capillary plexuses in both the macular and optic disc(OD)regions were recorded.Data were analyzed using SPSS 15.0;descriptive statistics were reported,group comparisons were performed with Chisquare,Kruskal–Wallis,and Bonferroni-corrected Mann–Whitney U tests,and relationships were assessed using Spearman correlation,with statistical significance set at P<0.05.RESULTS:A total of 160 eyes of 160 participants(110 females and 50 males with mean age 38.7±9.9y)who don’t smoke were divided into five groups:never,occasional,monthly,weekly and daily drinkers.The mean CST was 216.6±14.2μm and the mean SCT was 358.9±84.5μm.There was no statistically significantly difference in CST and SCT among the groups(P=0.890,0.799).Foveal superficial capillary plexuses(SCPs)VD was higher in monthly drinkers compared to occasional drinkers(P=0.015).Foveal VD in deep capillary plexus was also higher in monthly drinkers than in never and occasional drinkers(P=0.004,0.006).Nasal SCPs VD at the OD was higher in monthly drinkers compared to never drinkers(P=0.005).There was no significant difference FAZ area among the groups(P=0.071).CONCLUSION:Both superficial and deep microvascular structures in the inferior quadrants of macula are positively correlated with frequency of alcohol use.Also in our study results is that the monthly drinker group has uniquely higher VDs in both macula and OD.This leads us to consider moderate alcohol consumption may also have protective effects on retinal microcirculation.
基金supported by the Fundamental Research Funds for the Central Universities,Nos.G2021KY05107,G2021KY05101the National Natural Science Foundation of China,Nos.32071316,32211530049+1 种基金the Natural Science Foundation of Shaanxi Province,No.2022-JM482the Education and Teaching Reform Funds for the Central Universities,No.23GZ230102(all to LL and HH).
文摘Although previous studies have demonstrated that transcranial focused ultrasound stimulation protects the ischemic brain,clear criteria for the stimulation time window and intensity are lacking.Electrical impedance tomography enables real-time monitoring of changes in cerebral blood perfusion within the ischemic brain,but investigating the feasibility of using this method to assess post-stroke rehabilitation in vivo remains critical.In this study,ischemic stroke was induced in rats through middle cerebral artery occlusion surgery.Transcranial focused ultrasound stimulation was used to treat the rat model of ischemia,and electrical impedance tomography was used to measure impedance during both the acute stage of ischemia and the rehabilitation stage following the stimulation.Electrical impedance tomography results indicated that cerebral impedance increased after the onset of ischemia and decreased following transcranial focused ultrasound stimulation.Furthermore,the stimulation promoted motor function recovery,reduced cerebral infarction volume in the rat model of ischemic stroke,and induced the expression of brain-derived neurotrophic factor in the ischemic brain.Our results also revealed a significant correlation between the impedance of the ischemic brain post-intervention and improvements in behavioral scores and infarct volume.This study shows that daily administration of transcranial focused ultrasound stimulation for 20 minutes to the ischemic hemisphere 24 hours after cerebral ischemia enhanced motor recovery in a rat model of ischemia.Additionally,our findings indicate that electrical impedance tomography can serve as a valuable tool for quantitatively evaluating rehabilitation after ischemic stroke in vivo.These findings suggest the feasibility of using impedance data collected via electrical impedance tomography to clinically assess the effects of rehabilitatory interventions for patients with ischemic stroke.