期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
小瞳孔白内障超声乳化手术中应用MalyuginRing瞳孔扩张器的效果 被引量:1
1
作者 王进达 张景尚 +5 位作者 熊瑛 李婧 李晓霞 赵晶 朱谷雨 万修华 《中华眼视光学与视觉科学杂志》 CAS CSCD 2017年第8期502-506,共5页
目的:评价小瞳孔白内障超声乳化手术中应用MalyuginRing瞳孔扩张器的效果。方法:前瞻性病例对照研究。收集临床工作中的小瞳孔白内障患者27例(32眼),分为2组,其中术中采用2把器械瞳孔撕开操作21眼(Ⅰ组),采用MalyuginRing瞳孔... 目的:评价小瞳孔白内障超声乳化手术中应用MalyuginRing瞳孔扩张器的效果。方法:前瞻性病例对照研究。收集临床工作中的小瞳孔白内障患者27例(32眼),分为2组,其中术中采用2把器械瞳孔撕开操作21眼(Ⅰ组),采用MalyuginRing瞳孔扩张器扩张瞳孔11眼(Ⅱ组)。所有病例均行3.2mm透明角膜切口超声乳化白内障吸除IOL植入术,术后1周,1、3、6个月随访,比较手术前后最佳矫正视力(BCVA)、眼压(10P)、平均角膜曲率、角膜内皮细胞计数、瞳孔大小变化。采用独立样本t检验进行统计分析。结果:所有手术均由同一医师顺利完成,人工晶状体(IOL)100%囊袋内植入,无手术并发症发生。手术前与术后6个月比较:BCVA(LogMAR):Ⅰ组1.15±0.75w.0.30±0.21,Ⅱ组1.42±1.16W0.30±0.31;IOP:Ⅰ组(14.7±4.6)mmHgw.(14.1±6.4)mmHg,Ⅱ组(16.1±5.1)mmHg vs.(12.4±2.2)mmHg;平均角膜曲率:Ⅰ组(44.55±1.83)D vs.(44.94±2.70)D,Ⅱ组(44.72±1.55)D vs.(45.37±1.25)D;角膜内皮细胞计数:Ⅰ组(2490±498)/mm2 vs.(1486±612)/mm2,Ⅱ组(2620±989)/mm2vs(2089±729)/mm2;瞳孔直径:Ⅰ组(2.0±0.6)mm vs.(3.3±1.2)/mm,Ⅱ组(2.2±0.8)mnlⅧ.(3.5±1.2)mm。2组间手术前后参数比较,术后角膜内皮细胞计数差异具有统计学意义(t=-2.352,P=0.038),其他参数比较差异均无统计学意义。结论:小瞳孔白内障超声乳化手术时使用MalyuginRing瞳孔扩张器辅助不影响术后视力恢复和IOP及角膜曲率情况。术后瞳孔较术前扩大,MalyuginRing有助于减少术中角膜内皮细胞丢失。 展开更多
关键词 白内障 小瞳孔 瞳孔扩张器
原文传递
Series of cataract surgeries with I-ring pupil expansion ring
2
作者 Kenneth Lu Martin Garcia +1 位作者 Jack Tian Rustum Karanjia 《World Journal of Ophthalmology》 2019年第1期1-6,共6页
BACKGROUND The retrospective review of I-ring pupil expansion ring use is designed to examine the patient characteristics and associated surgical challenges in a clinical practice.The hypothesis is that I-ring provide... BACKGROUND The retrospective review of I-ring pupil expansion ring use is designed to examine the patient characteristics and associated surgical challenges in a clinical practice.The hypothesis is that I-ring provides a necessary additive tool in dealing with challenging cataract surgeries with small pupils.AIM To document the safety profile and use of I-ring pupil expansion ring in a clinical practice.METHODS A retrospective chart review of 12 consecutive cases within the same year(2016)of cataract surgeries employing I-ring pupil expansion ring(Beaver-Visitec,International)by a single surgeon at the same ambulatory surgical center was conducted.Demographic,pre-op,intra-op,and post-op data were recorded.Total number of cataract cases performed was also recorded.RESULTS 8 of 12 cases were planned I-ring cases.1 case was decided intraoperatively when femtosecond laser caused the pupil to shrink.The other 3 cases were also decided upon intraoperatively when pupil was deemed to be small.7 patients had IFIS from Flomax use.2 patients had pseudoexfoliation syndrome as the cause of small pupil.2 patients had narrow angles with brunescent cataracts.2 patients had pre-op partial zonular dehiscence.1 patient had 360o of posterior synechiae.2 cases had ruptured posterior capsule that required anterior vitrectomy.No complications were attributed to the pupil expansion ring.A total of 296 cataract surgeries were performed that year by the surgeon,making the rate of pupil ring use 4.1%.CONCLUSION Small pupil requiring pupil expansion ring during cataract surgery is often associated with other challenges,such as brunescent cataract,zonular weakness,and posterior synechiae in this series.I-ring helped to reduce at least one challenge in these difficult cases. 展开更多
关键词 malyugin RING I-ring Small PUPIL PSEUDOEXFOLIATION syndrome CATARACT Iris retraction IFIS Zonular dehiscence Challenging CATARACT surgeries PUPIL EXPANSION device
暂未订购
上一页 1 下一页 到第
使用帮助 返回顶部