The Macao Science Satellite-1(known as MSS-1)is the first scientific exploration satellite that was designed to measure the Earth's low latitude magnetic field at high resolution and with high precision by collect...The Macao Science Satellite-1(known as MSS-1)is the first scientific exploration satellite that was designed to measure the Earth's low latitude magnetic field at high resolution and with high precision by collecting data in a near-equatorial orbit.Magnetic field data from MSS-1's onboard Vector Fluxgate Magnetometer(VFM),collected at a sample rate of 50 Hz,allows us to detect and investigate sources of magnetic data contamination,from DC to relevant Nyquist frequency.Here we report two types of artificial disturbances in the VFM data.One is V-shaped events concentrated at night,with frequencies sweeping from the Nyquist frequency down to zero and back up.The other is 5-Hz events(ones that exhibit a distinct 5 Hz spectrum peak);these events are always accompanied by intervals of spiky signals,and are clearly related to the attitude control of the satellite.Our analyses show that VFM noise levels in daytime are systematically lower than in nighttime.The daily average noise levels exhibit a period of about 52 days.The V-shaped events are strongly correlated with higher VFM noise levels.展开更多
High-precision magnetic field measurements are crucial for understanding Earth’s internal structure,space environment,and dynamic geomagnetic variations.Data from the Fluxgate Magnetometer (FGM) on the Macao Science ...High-precision magnetic field measurements are crucial for understanding Earth’s internal structure,space environment,and dynamic geomagnetic variations.Data from the Fluxgate Magnetometer (FGM) on the Macao Science Satellite-1A (MSS-1A),added to data from other space-based magnetometers,should increase significantly the ability of scientists to observe changes in Earth’s magnetic field over time and space.Additionally,the MSS-1A’s FGM is intended to help identify magnetic disturbances affecting the spacecraft itself.This report focuses on the in-flight calibration of the MSS-1 FGM.A scalar calibration,independent of geomagnetic field models,was performed to correct offsets,sensitivities,and misalignment angles of the FGM.Using seven months of data,we find that the in-flight calibration parameters show good stability.We determined Euler angles describing the rotational relationship between the FGM and the Advanced Stellar Compass (ASC) coordinate system using two approaches:calibration with the CHAOS-7 geomagnetic field model,and simultaneous estimation of Euler angles and Gaussian spherical harmonic coefficients through self-consistent modeling.The accuracy of Euler angles describing the rotation was better than 18 arcsec.The calibrated FGM data exhibit good agreement with the calibrated data of the Vector Field Magnetometer (VFM),which is the primary vector magnetometer of the satellite.These calibration efforts have significantly improved the accuracy of the FGM measurements,which are now providing reliable data for geomagnetic field studies that promise to advance our understanding of the Earth’s magnetic environment.展开更多
Zero-and ultralow-field nuclear magnetic resonance(ZULF NMR)has experienced rapid development and provides an excellent tool for diverse research fields ranging from materials science and quantum information processin...Zero-and ultralow-field nuclear magnetic resonance(ZULF NMR)has experienced rapid development and provides an excellent tool for diverse research fields ranging from materials science and quantum information processing to fundamental physics.The detection of ZULF NMR signals in samples with natural abundance remains a challenging endeavor,due to the limited sensitivity of NMR detectors and thermal polarization.In this work,we demonstrate a femtotesla(fT)Potassium spin-exchange relaxation-free(SERF)magnetometer designed for ZULF NMR detection.A Potassium vapor cell with high buffer gas pressure and high atomic number density is used in the magnetometer.With absorption spectroscopy and SERF effect,the key parameters of the vapor cell are characterized and applied to optimize the magnetometer sensitivity.To combine our SERF magnetometer and ZULF NMR detection,a custom-made vacuum chamber is employed to keep NMR sample close to the magnetometer cell and protect the sample from undesired heating effects.Gradiometric measurement is performed to greatly reduce the magnetic noise.With the phase calibration applied,the gradiometric measurement achieves 7-fold enhancement in magnetic-field sensitivity compared to the single channel and has a magnetic noise floor of 1.2 fT/Hz^(1/2).Our SERF magnetometer exhibits high sensitivity and is promising to realize ZULF NMR detection of samples with natural abundance.展开更多
We explore the impact of pumping beams with different transverse intensity profiles on the performance of the spinexchange relaxation-free(SERF) atomic magnetometers(AMs). We conduct experiments comparing the traditio...We explore the impact of pumping beams with different transverse intensity profiles on the performance of the spinexchange relaxation-free(SERF) atomic magnetometers(AMs). We conduct experiments comparing the traditional Gaussian optically-pumped AM with that utilizing the flat-top optically-pumped(FTOP) method. Our findings reveal that the FTOP-based approach outperforms the conventional method, exhibiting a larger response, a narrower magnetic resonance linewidth, and a superior low-frequency noise performance. Specifically, the use of FTOP method leads to a 16% enhancement in average sensitivity within 1 Hz–30 Hz frequency range. Our research emphasizes the significance of achieving transverse polarization uniformity in AMs, providing insights for future optimization efforts and sensitivity improvements in miniaturized magnetometers.展开更多
Most triaxial-vectorial magnetic field measurements with spin-exchange relaxation free(SERF)atomic magnetometer(AM)are based on the quasi-steady-state solution of the Bloch equation.However,the responding speed of the...Most triaxial-vectorial magnetic field measurements with spin-exchange relaxation free(SERF)atomic magnetometer(AM)are based on the quasi-steady-state solution of the Bloch equation.However,the responding speed of these methods is greatly limited because the frequency of the modulation signal should be slow enough to ensure the validity of the quasi-steady-state solution.In this work,a new model to describe the response of the three-axis sensitive SERF AM with high modulation frequency is presented and verified.The response of alkali-atomic spin to high-frequency modulation field is further investigated by solving the Bloch equation in a modulation-frequency-dependence manner.This solution is well verified by our experiments and can offer a reference for selection of modulation frequencies.The result shows a potential to achieve a SERF AM operating in a geomagnetic field without heavy aluminum shielding when the modulation frequencies are selected properly.展开更多
Based on the parametric resonance magnetometer(PRM)theory,this paper establishes an experimen-tal system of PRM.The experimental results are consistent with the theoretical predictions.A PRM has been developed with se...Based on the parametric resonance magnetometer(PRM)theory,this paper establishes an experimen-tal system of PRM.The experimental results are consistent with the theoretical predictions.A PRM has been developed with sensitivity of 0.5 pT/Hz^(1/2),which can detect the magnitude of residual magnetic field;furthermore,a proportion-integration-differentiation(PID)closed-loop magnetic compensation system of the residual magnetic field also has been realized.Compared with open-loop compensation,the PID closed-loop compensation reduces the average value of the residual magnetic field in the z-axis direction from 0.0244nT to-0.0023nT,and the mean-square error from 0.2083 nT to 0.0691 nT.In the same way,the average value of the residual magnetic field in the y-axis direction is reduced from 0.0816nT to-0.0042nT,and the mean-square error from 0.1316nT to 0.0461 nT.The magnitude of residual magnetic fields in both directions is decreased to the order of picotesla(pT).In addition,based on the signal waveforms of the magnetometer,a method of verifying the effect of magnetic compensation is proposed.展开更多
Quantum enhanced metrology has the potential to go beyond the standard quantum limit and eventually to the ultimate Heisenberg bound.In particular,quantum probes prepared in nonclassical coherent states have recently ...Quantum enhanced metrology has the potential to go beyond the standard quantum limit and eventually to the ultimate Heisenberg bound.In particular,quantum probes prepared in nonclassical coherent states have recently been recognized as a useful resource for metrology.Hence,there has been considerable interest in constructing magnetic quantum sensors that combine high resolution and high sensitivity.Here,we explore a nanoscale magnetometer with quantum-enhanced sensitivity,based on 123Sb(I=7/2)nuclear spin doped in silicon,that takes advantage of techniques of spin-squeezing and coherent control.With the optimal squeezed initial state,the magnetic field sensitivity may be expected to approach 6 aT·Hz^(−1/2)·cm^(−3/2) and 603 nT·Hz^(−1/2) at the single-spin level.This magnetic sensor may provide a novel sensitive and high-resolution route to microscopic mapping of magnetic fields as well as other applications.展开更多
The laser-pumped potassium spin-exchange relaxation free (SERF) magnetometer is the most sensitive detector of magnetic field and has many important applications. We present the experimental results of our potassium...The laser-pumped potassium spin-exchange relaxation free (SERF) magnetometer is the most sensitive detector of magnetic field and has many important applications. We present the experimental results of our potassium SERF magne- tometer. A pump-probe approach is used to identify the unique spin dynamics of the atomic ensemble in the SERF regime. A single channel sensitivity of 8 f.THz-1/2 is achieved with our SERF magnetometer.展开更多
Many terrestrial experiments have been designed to detect domain walls composed of axions or axionlike particles(ALPs), which are promising candidates of dark matter. When the domain wall crosses over the Earth, the p...Many terrestrial experiments have been designed to detect domain walls composed of axions or axionlike particles(ALPs), which are promising candidates of dark matter. When the domain wall crosses over the Earth, the pseudoscalar field of ALPs could couple to the atomic spins. Such exotic spin-dependent couplings can be searched for by monitoring the transient-in-time change of the atomic spin precession frequency in the presence of a magnetic field. We propose here a single-species cesium atomic comagnetometer, which measures the spin precession frequencies of atoms in different ground-state hyperfine levels, to eliminate the common-mode magnetic-field variations and search for the exotic nonmagnetic couplings solely between protons and ALPs. With the single-species atomic comagnetometer, we experimentally rule out the possibility that the decay constant of the linear pseudoscalar couplings of ALPs to protons is fp■ 3.71 ×107 Ge V. The advanced system has the potential to constrain the constant to be fp■ 10.7 × 109 Ge V, promising to improve astrophysical constraint level by at least one order of magnitude. Our system could provide a sensitive detection method for the global network of optical magnetometers to search for exotic physics.展开更多
A miniature quad-channel optically pumped atomic magnetometer(OPM) has been developed based on the spinexchange relaxation-free(SERF) mechanism. With a vapor cell of size 8 mm×8 mm×8 mm, we have incorporated...A miniature quad-channel optically pumped atomic magnetometer(OPM) has been developed based on the spinexchange relaxation-free(SERF) mechanism. With a vapor cell of size 8 mm×8 mm×8 mm, we have incorporated four SERF magnetometer channels, which provides sufficient spatial resolution for magnetoencephalography(MEG). The four channels share the same laser beam for the best cancellation of common mode noise due to laser fluctuations. With gradient measurement, the sensitivities of the four sensors are better than 6 fT/Hz^(1/2), which is also good enough for MEG measurement. The vapor cell is heated to 160℃ by a novel nonmagnetic current-heating structure. Our sensor with high spatial resolution and compact size is particularly suitable for MEG systems.展开更多
This article presents a near-Earth satellite orbit estimation method for pico-satellite applications with light-weight and low-power requirements. The method provides orbit information autonomously from magnetometer a...This article presents a near-Earth satellite orbit estimation method for pico-satellite applications with light-weight and low-power requirements. The method provides orbit information autonomously from magnetometer and sun sensor, with an extended Kalman filter (EKF). Real-time position/velocity parameters are estimated with attitude independently from two quantities: the measured magnitude of the Earth’s magnetic field, and the measured dot product of the magnetic field vector and the sun vector. To guarantee the filter’s effectiveness, it is recommended that the sun sensor should at least have the same level of accuracy as magnetometer. Furthermore, to reduce filter’s computation expense, simplification methods in EKF’s Jacobian calculations are introduced and testified, and a polynomial model for fast magnetic field calculation is developed. With these methods, 50% of the computation expense in dynamic model propagation and 80% of the computation burden in measurement model calculation can be reduced. Tested with simulation data and compared with original magnetometer-only methods, filter achieves faster convergence and higher accuracy by 75% and 30% respectively, and the suggested simplification methods are proved to be harmless to filter’s estimation performance.展开更多
For the vector attitude determination, the traditional optimal algorithms which are based on quaternion estimator(QUEST) measurement noise model are complicated for just two observations. In our application, the mag...For the vector attitude determination, the traditional optimal algorithms which are based on quaternion estimator(QUEST) measurement noise model are complicated for just two observations. In our application, the magnetometer and accelerometer are not two comparable kinds of sensors and both are not small field-of-view sensors as well. So in this paper a new unit measurement model is derived. According to the Wahba problem, the optimal weights for each measurement are obtained by the error variance researches. Then an improved quaternion Gauss–Newton method is presented and adopted to acquire attitude. Eventually, simulation results and experimental validation employed to test the proposed method demonstrate the usefulness of the improved algorithm.展开更多
As one of the seven scientific payloads on board the Tianwen-1 orbiter,the Mars Orbiter Magnetometer(MOMAG)will measure the magnetic fields of and surrounding Mars to study its space environment and the interaction wi...As one of the seven scientific payloads on board the Tianwen-1 orbiter,the Mars Orbiter Magnetometer(MOMAG)will measure the magnetic fields of and surrounding Mars to study its space environment and the interaction with the solar wind.The instrument consists of two identical triaxial fluxgate magnetometer sensors,mounted on a 3.19 meter-long boom with a seperation of about 90 cm.The dual-magnetometers configuration will help eliminate the magnetic field interference generated by the spacecraft platform and payloads.The sensors are controlled by an electric box mounted inside the orbiter.Each magnetometer measures the ambient vector magnetic field over a wide dynamic range(to 10,000 nT per axis)with a resolution of 1.19 pT.Both magnetometers sample the ambient magnetic field at an intrinsic frequency of 128 Hz,but will operate in a model with alternating frequency between 1 and 32 Hz to meet telemetry allocations.展开更多
Satellite attitude information is essential for pico-satellite applications requiring light-weight,low-power,and fast-computation characteristics.The objective of this study is to provide a magnetometer-only attitude ...Satellite attitude information is essential for pico-satellite applications requiring light-weight,low-power,and fast-computation characteristics.The objective of this study is to provide a magnetometer-only attitude estimation method for a low-altitude Earth orbit,bias momentum pico-satellite.Based on two assumptions,the spacecraft spherical symmetry and damping of body rates,a linear kinematics model of a bias momentum satellite's pitch axis is derived,and the linear estimation algorithm is developed.The algorithm combines the linear Kalman filter(KF) with the classic three-axis attitude determination method(TRIAD).KF is used to estimate satellite's pitch axis orientation,while TRIAD is used to obtain information concerning the satellite's three-axis attitude.Simulation tests confirmed that the algorithm is suited to the time-varying model errors resulting from both assumptions.The estimate result keeps tracking satellite attitude motion during all damping,stable,and free rotating control stages.Compared with nonlinear algorithms,such as extended Kalman filer(EKF) and square root unscented Kalman filer(SRUKF),the algorithm presented here has an almost equal performance in terms of convergence time and estimation accuracy,while the consumption of computing resources is much lower.展开更多
We observed the steady-state visually evoked potential(SSVEP) from a healthy subject using a compact quad-channel potassium spin exchange relaxation-free(SERF) optically pumped magnetometer(OPM). To this end, 30 s of ...We observed the steady-state visually evoked potential(SSVEP) from a healthy subject using a compact quad-channel potassium spin exchange relaxation-free(SERF) optically pumped magnetometer(OPM). To this end, 30 s of data were collected, and SSVEP-related magnetic responses with signal intensity ranging from 150 fT to 300 f T were observed for all four channels. The corresponding signal to noise ratio(SNR) was in the range of 3.5–5.5. We then used different channels to operate the sensor as a gradiometer. In the specific case of detecting SSVEP, we noticed that the short channel separation distance led to a strongly diminished gradiometer signal. Although not optimal for the case of SSVEP detection, this set-up can prove to be highly useful for other magnetoencephalography(MEG) paradigms that require good noise cancellation.Considering its compactness, low cost, and good performance, the K-SERF sensor has great potential for biomagnetic field measurements and brain-computer interfaces(BCI).展开更多
Exploration of deep mineralization,particularly where the mineralization of interest is covered by a conductive overburden,is still a challenge for the conventional transient electromagnetic(TEM)method,which measures ...Exploration of deep mineralization,particularly where the mineralization of interest is covered by a conductive overburden,is still a challenge for the conventional transient electromagnetic(TEM)method,which measures TEM response using induction coils as the sensor.However,sensors such as fluxgate and superconductive quantum interfere device(SQUID)magnetometers can measure the B-field directly,which can provide more reliable deep information for mineralization exploration.In this paper,we report on the research and development of our newly developed high-temperature su-perconductor(HTS)SQUID magnetometer,which is cooled by liquid nitrogen at 77 K,and its applica-tion in TEM measurement for deep exploration in a gold deposit in China.This improved SQUID magnetometer version has a good performance with noise(60 fT/√Hz),slew rate(0.8 mT/S),dynamic range(100 dB),sensitivity(6.25 mV/nT),and bandwidth(DC-20 kHz).To find deep and peripheral ore in the Baiyun gold deposit located in Liaoning Province,NE China,both the SQUID magnetometer and induction coil were used for TEM data acquisition.Results show that TEM can detect the distribution of local strata and the faults contained within them.Results also indicate that the SQUID magnetome-ter has superior response performance for response over geological targets with slower decay time when compared to the induction coil signals.The SQUID magnetometer is more sensitive at observing the induced-polarization effect which is closely related to the ore-controlling faults.展开更多
The space-borne fluxgate magnetometer(FGM)requires regular in-flight calibration to obtain its zero offset.Recently,Wang GQ and Pan ZH(2021a)developed a new method for the zero offset calibration based on the properti...The space-borne fluxgate magnetometer(FGM)requires regular in-flight calibration to obtain its zero offset.Recently,Wang GQ and Pan ZH(2021a)developed a new method for the zero offset calibration based on the properties of Alfvén waves.They found that an optimal offset line(OOL)exists in the offset cube for a pure Alfvén wave and that the zero offset can be determined by the intersection of at least two nonparallel OOLs.Because no pure Alfvén waves exist in the interplanetary magnetic field,calculation of the zero offset relies on the selection of highly Alfvénic fluctuation events.Here,we propose an automatic procedure to find highly Alfvénic fluctuations in the solar wind and calculate the zero offset.This procedure includes three parts:(1)selecting potential Alfvénic fluctuation events,(2)obtaining the OOL,and(3)determining the zero offset.We tested our automatic procedure by applying it to the magnetic field data measured by the FGM onboard the Venus Express.The tests revealed that our automatic procedure was able to achieve results as good as those determined by the Davis-Smith method.One advantage of our procedure is that the selection criteria and the process for selecting the highly Alfvénic fluctuation events are simpler.Our automatic procedure could also be applied to find fluctuation events for the Davis-Smith method.展开更多
Four levels of the data from the search coil magnetometer(SCM) onboard the China Seismo-Electromagnetic Satellite(CSES)are defined and described. The data in different levels all contain three components of the wavefo...Four levels of the data from the search coil magnetometer(SCM) onboard the China Seismo-Electromagnetic Satellite(CSES)are defined and described. The data in different levels all contain three components of the waveform and/or spectrum of the induced magnetic field around the orbit in the frequency range of 10 Hz to 20 kHz; these are divided into an ultra-low-frequency band(ULF,10–200 Hz), an extremely low frequency band(ELF, 200–2200 Hz), and a very low frequency band(VLF, 1.8–20 kHz). Examples of data products for Level-2, Level-3, and Level-4 are presented. The initial results obtained in the commission test phase demonstrated that the SCM was in a normal operational status and that the data are of high enough quality to reliably capture most space weather events related to low-frequency geomagnetic disturbances.展开更多
A transverse relaxation determination of spin-exchange relaxation free (SERF) magnetometer based on polarization modulation technique is proposed. Compared with the radio-frequency (RF) excitation and light intens...A transverse relaxation determination of spin-exchange relaxation free (SERF) magnetometer based on polarization modulation technique is proposed. Compared with the radio-frequency (RF) excitation and light intensity excitation meth- ods used in SERF magnetometer, the light polarization modulation method has a high stability in low-frequency range, which indicates a more accurate transverse relaxation measurement.展开更多
In a pico-satellite with small volume, measurements from on-board three-axis magnetometer (TAM) are not accurate, as it can be easily disturbed by other electronic systems. To improve its accuracy, a scheme of compe...In a pico-satellite with small volume, measurements from on-board three-axis magnetometer (TAM) are not accurate, as it can be easily disturbed by other electronic systems. To improve its accuracy, a scheme of compensation methods is introduced in this article. The scheme is based on an improved meast, rement model of pico-satellite TAM, and it mainly consists of three steps. First, in satellite design stage, several techniques are recommended to simplify the afterwards compensations. Then after satellite assembly, TAM ground tests and pre-launch calibration with least-square batch filter are introduced to improve magnetometer performance. At the end, a post-launch calibration with unscented Kalman filter (UKF) is implemented with in-orbit data. The compensation scheme is used in the development of Chinese pico-satellite ZDPS-1A made by Zhejiang University. Results show that with the introduced compensation scheme, the maximum error of ZDPS-1A TAM can be reduced from 80 mG to 6 naG (1 G=10^-4T).展开更多
基金supported by the National Key R&D Program of China(Grant2022YFF0503700)the National Natural Science Foundation of China(42474200 and 42174186)。
文摘The Macao Science Satellite-1(known as MSS-1)is the first scientific exploration satellite that was designed to measure the Earth's low latitude magnetic field at high resolution and with high precision by collecting data in a near-equatorial orbit.Magnetic field data from MSS-1's onboard Vector Fluxgate Magnetometer(VFM),collected at a sample rate of 50 Hz,allows us to detect and investigate sources of magnetic data contamination,from DC to relevant Nyquist frequency.Here we report two types of artificial disturbances in the VFM data.One is V-shaped events concentrated at night,with frequencies sweeping from the Nyquist frequency down to zero and back up.The other is 5-Hz events(ones that exhibit a distinct 5 Hz spectrum peak);these events are always accompanied by intervals of spiky signals,and are clearly related to the attitude control of the satellite.Our analyses show that VFM noise levels in daytime are systematically lower than in nighttime.The daily average noise levels exhibit a period of about 52 days.The V-shaped events are strongly correlated with higher VFM noise levels.
文摘High-precision magnetic field measurements are crucial for understanding Earth’s internal structure,space environment,and dynamic geomagnetic variations.Data from the Fluxgate Magnetometer (FGM) on the Macao Science Satellite-1A (MSS-1A),added to data from other space-based magnetometers,should increase significantly the ability of scientists to observe changes in Earth’s magnetic field over time and space.Additionally,the MSS-1A’s FGM is intended to help identify magnetic disturbances affecting the spacecraft itself.This report focuses on the in-flight calibration of the MSS-1 FGM.A scalar calibration,independent of geomagnetic field models,was performed to correct offsets,sensitivities,and misalignment angles of the FGM.Using seven months of data,we find that the in-flight calibration parameters show good stability.We determined Euler angles describing the rotational relationship between the FGM and the Advanced Stellar Compass (ASC) coordinate system using two approaches:calibration with the CHAOS-7 geomagnetic field model,and simultaneous estimation of Euler angles and Gaussian spherical harmonic coefficients through self-consistent modeling.The accuracy of Euler angles describing the rotation was better than 18 arcsec.The calibrated FGM data exhibit good agreement with the calibrated data of the Vector Field Magnetometer (VFM),which is the primary vector magnetometer of the satellite.These calibration efforts have significantly improved the accuracy of the FGM measurements,which are now providing reliable data for geomagnetic field studies that promise to advance our understanding of the Earth’s magnetic environment.
基金supported by National Science Foundation of China(Grant Nos.T2388102,11927811,92476204,12150014,12205296,12274395,and 12261160569)Innovation Program for Quantum Science and Technology(Grant No.2021ZD0303205)+1 种基金Youth Innovation Promotion Association(Grant No.2023474)Chinese Academy of Sciences Magnetic Resonance Technology Alliance Research Instrument and Equipment Development/Functional Development(Grant No.2022GZL003).
文摘Zero-and ultralow-field nuclear magnetic resonance(ZULF NMR)has experienced rapid development and provides an excellent tool for diverse research fields ranging from materials science and quantum information processing to fundamental physics.The detection of ZULF NMR signals in samples with natural abundance remains a challenging endeavor,due to the limited sensitivity of NMR detectors and thermal polarization.In this work,we demonstrate a femtotesla(fT)Potassium spin-exchange relaxation-free(SERF)magnetometer designed for ZULF NMR detection.A Potassium vapor cell with high buffer gas pressure and high atomic number density is used in the magnetometer.With absorption spectroscopy and SERF effect,the key parameters of the vapor cell are characterized and applied to optimize the magnetometer sensitivity.To combine our SERF magnetometer and ZULF NMR detection,a custom-made vacuum chamber is employed to keep NMR sample close to the magnetometer cell and protect the sample from undesired heating effects.Gradiometric measurement is performed to greatly reduce the magnetic noise.With the phase calibration applied,the gradiometric measurement achieves 7-fold enhancement in magnetic-field sensitivity compared to the single channel and has a magnetic noise floor of 1.2 fT/Hz^(1/2).Our SERF magnetometer exhibits high sensitivity and is promising to realize ZULF NMR detection of samples with natural abundance.
基金Project supported by the National Natural Science Foundation of China (Grant No. 62303029)the China Postdoctoral Science Foundation (Grant No. 2022M720364)the Innovation Program for Quantum Science and Technology (Grant Nos. 2021ZD0300500 and 2021ZD0300503)。
文摘We explore the impact of pumping beams with different transverse intensity profiles on the performance of the spinexchange relaxation-free(SERF) atomic magnetometers(AMs). We conduct experiments comparing the traditional Gaussian optically-pumped AM with that utilizing the flat-top optically-pumped(FTOP) method. Our findings reveal that the FTOP-based approach outperforms the conventional method, exhibiting a larger response, a narrower magnetic resonance linewidth, and a superior low-frequency noise performance. Specifically, the use of FTOP method leads to a 16% enhancement in average sensitivity within 1 Hz–30 Hz frequency range. Our research emphasizes the significance of achieving transverse polarization uniformity in AMs, providing insights for future optimization efforts and sensitivity improvements in miniaturized magnetometers.
基金Project supported by the National Natural Science Foundation of China(Grant No.42074216).
文摘Most triaxial-vectorial magnetic field measurements with spin-exchange relaxation free(SERF)atomic magnetometer(AM)are based on the quasi-steady-state solution of the Bloch equation.However,the responding speed of these methods is greatly limited because the frequency of the modulation signal should be slow enough to ensure the validity of the quasi-steady-state solution.In this work,a new model to describe the response of the three-axis sensitive SERF AM with high modulation frequency is presented and verified.The response of alkali-atomic spin to high-frequency modulation field is further investigated by solving the Bloch equation in a modulation-frequency-dependence manner.This solution is well verified by our experiments and can offer a reference for selection of modulation frequencies.The result shows a potential to achieve a SERF AM operating in a geomagnetic field without heavy aluminum shielding when the modulation frequencies are selected properly.
基金the Shanghai Aerospace Advanced Technology Joint Research Fund(No.USCAST2019-23)the Oceanic Interdisciplinary Program of Shanghai Jiao Tong University(No.SL2021ZD202)。
文摘Based on the parametric resonance magnetometer(PRM)theory,this paper establishes an experimen-tal system of PRM.The experimental results are consistent with the theoretical predictions.A PRM has been developed with sensitivity of 0.5 pT/Hz^(1/2),which can detect the magnitude of residual magnetic field;furthermore,a proportion-integration-differentiation(PID)closed-loop magnetic compensation system of the residual magnetic field also has been realized.Compared with open-loop compensation,the PID closed-loop compensation reduces the average value of the residual magnetic field in the z-axis direction from 0.0244nT to-0.0023nT,and the mean-square error from 0.2083 nT to 0.0691 nT.In the same way,the average value of the residual magnetic field in the y-axis direction is reduced from 0.0816nT to-0.0042nT,and the mean-square error from 0.1316nT to 0.0461 nT.The magnitude of residual magnetic fields in both directions is decreased to the order of picotesla(pT).In addition,based on the signal waveforms of the magnetometer,a method of verifying the effect of magnetic compensation is proposed.
基金the National Natural Science Foundation of China(Grant Nos.1212200199,12122506,12004165,12275117,and 12204230)Guangdong Basic and Applied Basic Research Foundation(Grant Nos.2021B1515020070 and 2022B1515020074)+1 种基金Guangdong Provincial Key Laboratory(Grant No.2019B121203002)Shen-zhen Science and Technology Program(Grant Nos.KQTD20200820113010023,RCBS20200714114820298,and RCYX20200714114522109).
文摘Quantum enhanced metrology has the potential to go beyond the standard quantum limit and eventually to the ultimate Heisenberg bound.In particular,quantum probes prepared in nonclassical coherent states have recently been recognized as a useful resource for metrology.Hence,there has been considerable interest in constructing magnetic quantum sensors that combine high resolution and high sensitivity.Here,we explore a nanoscale magnetometer with quantum-enhanced sensitivity,based on 123Sb(I=7/2)nuclear spin doped in silicon,that takes advantage of techniques of spin-squeezing and coherent control.With the optimal squeezed initial state,the magnetic field sensitivity may be expected to approach 6 aT·Hz^(−1/2)·cm^(−3/2) and 603 nT·Hz^(−1/2) at the single-spin level.This magnetic sensor may provide a novel sensitive and high-resolution route to microscopic mapping of magnetic fields as well as other applications.
基金supported by the National Natural Science Foundation of China(Grant No.61227902)
文摘The laser-pumped potassium spin-exchange relaxation free (SERF) magnetometer is the most sensitive detector of magnetic field and has many important applications. We present the experimental results of our potassium SERF magne- tometer. A pump-probe approach is used to identify the unique spin dynamics of the atomic ensemble in the SERF regime. A single channel sensitivity of 8 f.THz-1/2 is achieved with our SERF magnetometer.
基金the National Natural Science Foundation of China(Grant No.62071012)the National Science Fund for Distinguished Young Scholars of China(Grant No.61225003)National Hi-Tech Research and Development Program of China.
文摘Many terrestrial experiments have been designed to detect domain walls composed of axions or axionlike particles(ALPs), which are promising candidates of dark matter. When the domain wall crosses over the Earth, the pseudoscalar field of ALPs could couple to the atomic spins. Such exotic spin-dependent couplings can be searched for by monitoring the transient-in-time change of the atomic spin precession frequency in the presence of a magnetic field. We propose here a single-species cesium atomic comagnetometer, which measures the spin precession frequencies of atoms in different ground-state hyperfine levels, to eliminate the common-mode magnetic-field variations and search for the exotic nonmagnetic couplings solely between protons and ALPs. With the single-species atomic comagnetometer, we experimentally rule out the possibility that the decay constant of the linear pseudoscalar couplings of ALPs to protons is fp■ 3.71 ×107 Ge V. The advanced system has the potential to constrain the constant to be fp■ 10.7 × 109 Ge V, promising to improve astrophysical constraint level by at least one order of magnitude. Our system could provide a sensitive detection method for the global network of optical magnetometers to search for exotic physics.
基金Project supported by the National Key Research and Development Program of China(Grant Nos.2016YFA0300600 and 2016YFA0301500)the Strategic Priority Research Program of the Chinese Academy of Sciences(Grant No.XDB07030000)the National Natural Science Foundation of China(Grant No.11474347)
文摘A miniature quad-channel optically pumped atomic magnetometer(OPM) has been developed based on the spinexchange relaxation-free(SERF) mechanism. With a vapor cell of size 8 mm×8 mm×8 mm, we have incorporated four SERF magnetometer channels, which provides sufficient spatial resolution for magnetoencephalography(MEG). The four channels share the same laser beam for the best cancellation of common mode noise due to laser fluctuations. With gradient measurement, the sensitivities of the four sensors are better than 6 fT/Hz^(1/2), which is also good enough for MEG measurement. The vapor cell is heated to 160℃ by a novel nonmagnetic current-heating structure. Our sensor with high spatial resolution and compact size is particularly suitable for MEG systems.
基金New Century Program for Excellent Talents of Minis-try of Education of China (NCET-06-0514)China Postdoctoral Science Foundation (20081458, 20080431306)
文摘This article presents a near-Earth satellite orbit estimation method for pico-satellite applications with light-weight and low-power requirements. The method provides orbit information autonomously from magnetometer and sun sensor, with an extended Kalman filter (EKF). Real-time position/velocity parameters are estimated with attitude independently from two quantities: the measured magnitude of the Earth’s magnetic field, and the measured dot product of the magnetic field vector and the sun vector. To guarantee the filter’s effectiveness, it is recommended that the sun sensor should at least have the same level of accuracy as magnetometer. Furthermore, to reduce filter’s computation expense, simplification methods in EKF’s Jacobian calculations are introduced and testified, and a polynomial model for fast magnetic field calculation is developed. With these methods, 50% of the computation expense in dynamic model propagation and 80% of the computation burden in measurement model calculation can be reduced. Tested with simulation data and compared with original magnetometer-only methods, filter achieves faster convergence and higher accuracy by 75% and 30% respectively, and the suggested simplification methods are proved to be harmless to filter’s estimation performance.
文摘For the vector attitude determination, the traditional optimal algorithms which are based on quaternion estimator(QUEST) measurement noise model are complicated for just two observations. In our application, the magnetometer and accelerometer are not two comparable kinds of sensors and both are not small field-of-view sensors as well. So in this paper a new unit measurement model is derived. According to the Wahba problem, the optimal weights for each measurement are obtained by the error variance researches. Then an improved quaternion Gauss–Newton method is presented and adopted to acquire attitude. Eventually, simulation results and experimental validation employed to test the proposed method demonstrate the usefulness of the improved algorithm.
基金supported by the Chinese National Space Administration,and the science team of MOMAG is supported by the Strategic Priority Program(Grant No.XDB41000000)the key Research Program of Frontier Sciences(No.QYZDB-SSW-DQC015)of the Chinese Academy of Sciences.
文摘As one of the seven scientific payloads on board the Tianwen-1 orbiter,the Mars Orbiter Magnetometer(MOMAG)will measure the magnetic fields of and surrounding Mars to study its space environment and the interaction with the solar wind.The instrument consists of two identical triaxial fluxgate magnetometer sensors,mounted on a 3.19 meter-long boom with a seperation of about 90 cm.The dual-magnetometers configuration will help eliminate the magnetic field interference generated by the spacecraft platform and payloads.The sensors are controlled by an electric box mounted inside the orbiter.Each magnetometer measures the ambient vector magnetic field over a wide dynamic range(to 10,000 nT per axis)with a resolution of 1.19 pT.Both magnetometers sample the ambient magnetic field at an intrinsic frequency of 128 Hz,but will operate in a model with alternating frequency between 1 and 32 Hz to meet telemetry allocations.
基金supported by the Program for New Century Excellent Talents in University (No. NCET-06-0514),Chinathe Postdoctoral Science Foundation of China (Nos. 20081458 and 20080431306)
文摘Satellite attitude information is essential for pico-satellite applications requiring light-weight,low-power,and fast-computation characteristics.The objective of this study is to provide a magnetometer-only attitude estimation method for a low-altitude Earth orbit,bias momentum pico-satellite.Based on two assumptions,the spacecraft spherical symmetry and damping of body rates,a linear kinematics model of a bias momentum satellite's pitch axis is derived,and the linear estimation algorithm is developed.The algorithm combines the linear Kalman filter(KF) with the classic three-axis attitude determination method(TRIAD).KF is used to estimate satellite's pitch axis orientation,while TRIAD is used to obtain information concerning the satellite's three-axis attitude.Simulation tests confirmed that the algorithm is suited to the time-varying model errors resulting from both assumptions.The estimate result keeps tracking satellite attitude motion during all damping,stable,and free rotating control stages.Compared with nonlinear algorithms,such as extended Kalman filer(EKF) and square root unscented Kalman filer(SRUKF),the algorithm presented here has an almost equal performance in terms of convergence time and estimation accuracy,while the consumption of computing resources is much lower.
基金Project supported by the National Key Research and Development Program of China(Grant Nos.2016YFA0300600 and 2016YFA0301500)the Strategic Priority Research Program of Chinese Academy of Sciences(Grant Nos.XDB07030000 and XDBS32000000)+1 种基金the National Natural Science Foundation of China(Grant Nos.11474347 and 31730039)the Fund from the Ministry of Science and Technology of China(Grant No.2015CB351701)
文摘We observed the steady-state visually evoked potential(SSVEP) from a healthy subject using a compact quad-channel potassium spin exchange relaxation-free(SERF) optically pumped magnetometer(OPM). To this end, 30 s of data were collected, and SSVEP-related magnetic responses with signal intensity ranging from 150 fT to 300 f T were observed for all four channels. The corresponding signal to noise ratio(SNR) was in the range of 3.5–5.5. We then used different channels to operate the sensor as a gradiometer. In the specific case of detecting SSVEP, we noticed that the short channel separation distance led to a strongly diminished gradiometer signal. Although not optimal for the case of SSVEP detection, this set-up can prove to be highly useful for other magnetoencephalography(MEG) paradigms that require good noise cancellation.Considering its compactness, low cost, and good performance, the K-SERF sensor has great potential for biomagnetic field measurements and brain-computer interfaces(BCI).
基金This study was supported by the National Key Research and Development Project of China(No.2018YFC0603803)Fundamental Research Funds of Chinese Academy of Geological Sciences(Nos.AS2020Y01,AS2020P01).
文摘Exploration of deep mineralization,particularly where the mineralization of interest is covered by a conductive overburden,is still a challenge for the conventional transient electromagnetic(TEM)method,which measures TEM response using induction coils as the sensor.However,sensors such as fluxgate and superconductive quantum interfere device(SQUID)magnetometers can measure the B-field directly,which can provide more reliable deep information for mineralization exploration.In this paper,we report on the research and development of our newly developed high-temperature su-perconductor(HTS)SQUID magnetometer,which is cooled by liquid nitrogen at 77 K,and its applica-tion in TEM measurement for deep exploration in a gold deposit in China.This improved SQUID magnetometer version has a good performance with noise(60 fT/√Hz),slew rate(0.8 mT/S),dynamic range(100 dB),sensitivity(6.25 mV/nT),and bandwidth(DC-20 kHz).To find deep and peripheral ore in the Baiyun gold deposit located in Liaoning Province,NE China,both the SQUID magnetometer and induction coil were used for TEM data acquisition.Results show that TEM can detect the distribution of local strata and the faults contained within them.Results also indicate that the SQUID magnetome-ter has superior response performance for response over geological targets with slower decay time when compared to the induction coil signals.The SQUID magnetometer is more sensitive at observing the induced-polarization effect which is closely related to the ore-controlling faults.
基金financially supported by the Shenzhen Science and Technology Research Program(grant no.JCYJ2021032412141-2034)the National Natural Science Foundation of China(grant nos.41804157,41774171,41774167,41974205,41804157,and 41904156)+3 种基金financial support from the pre-research Project on Civil Aerospace Technologies(grant no.D020103)funded by the China National Space Administrationthe 111 Project(grant no.B18017)the Chinese Academy of Sciences Center for Excellence in Comparative Planetologythe Macao Foundation.
文摘The space-borne fluxgate magnetometer(FGM)requires regular in-flight calibration to obtain its zero offset.Recently,Wang GQ and Pan ZH(2021a)developed a new method for the zero offset calibration based on the properties of Alfvén waves.They found that an optimal offset line(OOL)exists in the offset cube for a pure Alfvén wave and that the zero offset can be determined by the intersection of at least two nonparallel OOLs.Because no pure Alfvén waves exist in the interplanetary magnetic field,calculation of the zero offset relies on the selection of highly Alfvénic fluctuation events.Here,we propose an automatic procedure to find highly Alfvénic fluctuations in the solar wind and calculate the zero offset.This procedure includes three parts:(1)selecting potential Alfvénic fluctuation events,(2)obtaining the OOL,and(3)determining the zero offset.We tested our automatic procedure by applying it to the magnetic field data measured by the FGM onboard the Venus Express.The tests revealed that our automatic procedure was able to achieve results as good as those determined by the Davis-Smith method.One advantage of our procedure is that the selection criteria and the process for selecting the highly Alfvénic fluctuation events are simpler.Our automatic procedure could also be applied to find fluctuation events for the Davis-Smith method.
基金supported by the State Key R&D Project (Grant No. 2016YFE0122200)the Civil Aerospace Scientific Research Project “Data calibration and validation for CSES, ”the Central-Level Public Welfare Research Projects of the Institute of Crustal Dynamics Institute, China Earthquake Administration (Grant No. ZDJ2017-21)
文摘Four levels of the data from the search coil magnetometer(SCM) onboard the China Seismo-Electromagnetic Satellite(CSES)are defined and described. The data in different levels all contain three components of the waveform and/or spectrum of the induced magnetic field around the orbit in the frequency range of 10 Hz to 20 kHz; these are divided into an ultra-low-frequency band(ULF,10–200 Hz), an extremely low frequency band(ELF, 200–2200 Hz), and a very low frequency band(VLF, 1.8–20 kHz). Examples of data products for Level-2, Level-3, and Level-4 are presented. The initial results obtained in the commission test phase demonstrated that the SCM was in a normal operational status and that the data are of high enough quality to reliably capture most space weather events related to low-frequency geomagnetic disturbances.
基金Project supported by the National Natural Science Foundation of China(Grant No.61227902)the National Key R&D Program of China(Grant No.2017YFB0503100)the Natural Science Foundation of Beijing Municipality,China(Grant No.4162038)
文摘A transverse relaxation determination of spin-exchange relaxation free (SERF) magnetometer based on polarization modulation technique is proposed. Compared with the radio-frequency (RF) excitation and light intensity excitation meth- ods used in SERF magnetometer, the light polarization modulation method has a high stability in low-frequency range, which indicates a more accurate transverse relaxation measurement.
基金Program for New Century Excellent Talents in University (NCET-06-0514)China Postdoctoral Science Foundation (20081458, 20080431306)
文摘In a pico-satellite with small volume, measurements from on-board three-axis magnetometer (TAM) are not accurate, as it can be easily disturbed by other electronic systems. To improve its accuracy, a scheme of compensation methods is introduced in this article. The scheme is based on an improved meast, rement model of pico-satellite TAM, and it mainly consists of three steps. First, in satellite design stage, several techniques are recommended to simplify the afterwards compensations. Then after satellite assembly, TAM ground tests and pre-launch calibration with least-square batch filter are introduced to improve magnetometer performance. At the end, a post-launch calibration with unscented Kalman filter (UKF) is implemented with in-orbit data. The compensation scheme is used in the development of Chinese pico-satellite ZDPS-1A made by Zhejiang University. Results show that with the introduced compensation scheme, the maximum error of ZDPS-1A TAM can be reduced from 80 mG to 6 naG (1 G=10^-4T).