期刊文献+
共找到58篇文章
< 1 2 3 >
每页显示 20 50 100
Microfluidic-directed magnetic controlling supraballs with multi-responsive anisotropic photonic crystal structures
1
作者 Lu-Wei Hao Ji-Dong Liu +7 位作者 Qing Li Ren-Kun Qing Yun-Ya He Jiazhuang Guo Ge Li Liangliang Zhu Chen Xu Su Chen 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2021年第22期203-211,共9页
The design and fabrication of anisotropic photonic crystal supraballs with multiple responses are highly desirable for versatile environmental sensing and flexible displaying.Herein,we developed an available strategy ... The design and fabrication of anisotropic photonic crystal supraballs with multiple responses are highly desirable for versatile environmental sensing and flexible displaying.Herein,we developed an available strategy to construct a series of multi-responsive magnetic colloidal photonic crystal(CPC)supraballs with Janus and molecular-analogue structures.Initially,the humidity and temperature sensitive CPC supraballs were obtained via immobilization of polyacrylamide(PAM)and polyisopropylacrylamide(PNIPAM)hydrogels into the CPC structure,respectively,and CdTe/ZnS quantum dots endow the supraballs fluorescent signal under UV light.Furthermore,Fe_(3)O_(4) nanoparticles(NPs)were served as a magnetic hemisphere to construct CPC Janus supraballs which can be subsequently assembled into three different molecular-shaped cluster particles that integrate more response types via Fe_(3)O_(4) NPs hemisphere coalescence to a magnetic coupling center,recognizing multiple responses simultaneously that correspond the environmental altering.In addition,2D polychromatic patterns with sensitive CPC pixels printed by automatic printing system were demonstrated,which could monitor the changes of temperature and humidity.The multi-responsive magnetic controlling supraballs and 2D patterns reveal the promising applications in environmental sensing,anti-counterfeiting and displaying. 展开更多
关键词 Photonic crystal Multiple responses Optical sensing Supraballs MICROFLUIDICS magnetic control
原文传递
Analysis on the Fast Excitation System of Composite Magnetic Controllable Reactor
2
作者 Cuizhi WANG 《International English Education Research》 2014年第10期40-42,共3页
The fast excitation system of a composite magnetic controllable reactor is introduced. In this excitation system, a bidirectional function (i.e. fast forward excitation and backward forcible demagnetization) is avai... The fast excitation system of a composite magnetic controllable reactor is introduced. In this excitation system, a bidirectional function (i.e. fast forward excitation and backward forcible demagnetization) is available, which can significantly improve the response speed, performances, and application scope of magnetic controllable reactor. 展开更多
关键词 COMPOSITE FAST EXCITATION magnetic control REACTOR
在线阅读 下载PDF
Bio-inspired Magnetic Helical Miniature Robots:Mechanisms,Control and Biomedical Applications
3
作者 Aoji Zhu Yangmin Li +1 位作者 Yongping Zheng Lidong Yang 《Journal of Bionic Engineering》 2025年第6期2805-2830,共26页
Inspired by bacterial motility mechanisms,Magnetic Helical Miniature Robots(MHMRs)exhibit promising applications in biomedical fields due to their efficient locomotion and compatibility with biological tissues.In this... Inspired by bacterial motility mechanisms,Magnetic Helical Miniature Robots(MHMRs)exhibit promising applications in biomedical fields due to their efficient locomotion and compatibility with biological tissues.In this review,we systematically survey the basics of MHMRs,from propulsion mechanism,magnetization and control methods to biomedical applications,aiming to provide readers with an easily understandable overview and fundamental knowledge on implementing MHMRs.The MHMRs are actuated by rotating magnetic fields,achieving steering and rotation through magnetic torque,and converting rotation into forward motion through the helical structure.Magnetization methods for MHMRs are reviewed into three types:attaching magnets,magnetic coatings,and magnetic powder doping.Additionally,this review discusses the control methods for MHMRs,covering imaging techniques,path tracking control—including classical control algorithms and increasingly popular learning-based methods,and swarm control.Subsequently,a comprehensive survey is conducted on the biomedical applications of MHMRs in the treatment of vascular diseases,drug delivery,cell delivery,and their integration with catheters.We finally provide a perspective about future challenges in MHMR research,including enhancing functional design capabilities,developing swarm-assisted independent control mechanisms,refining in vivo imaging techniques,and ensuring robust biocompatibility for safe medical use. 展开更多
关键词 Biologically-inspired robots Miniature robots magnetic control Biomedical application
在线阅读 下载PDF
Carbonated soft drink for gastric preparation for magnetically controlled capsule endoscopy:An open-label randomized controlled trial
4
作者 Jia-Hui Zhu Xiao Liu +8 位作者 Wei Zhou Xiao-Nan Xu Wen-Da Sheng Yi-Lin Han Xiao-Ou Qiu Ya-Wei Liu Yang-Yang Qian Zhuan Liao Zhao-Shen Li 《World Journal of Gastroenterology》 2025年第24期85-95,共11页
BACKGROUND The clinical effectiveness of magnetically controlled capsule endoscopy(MCE)is well established.However,problems,such as abdominal distension,insufficient gastric filling,and prolonged gastric retention tim... BACKGROUND The clinical effectiveness of magnetically controlled capsule endoscopy(MCE)is well established.However,problems,such as abdominal distension,insufficient gastric filling,and prolonged gastric retention time,persist with MCE gastric preparations.AIM To compare gastric filling using a carbonated soft drink with that using pure water during MCE.METHODS We performed an open-label randomised controlled trial at the Endoscopy Centre of Changhai Hospital in Shanghai.Patients aged 18-80 years,with or without gastrointestinal symptoms,scheduled for MCE were consecutively recruited.Those who provided informed consent were randomly assigned to the carbonated soft drink group(C group)or water group(W group)in a 1:1 ratio.For patients in the W group,1000 mL of water was ingested to distend the stomach,whereas for patients in the C group,550 mL of carbonated soft drink was provided,and patients were required to drink quickly while minimising burping.The primary endpoint was the number of patients with a gastric filling score of≥4 within 5 minutes after the capsule entered the stomach.RESULTS From December 3,2020 to May 17,2021,252 patients(141 men),aged 18-77 years,were assigned to the C(n=126)and W(n=126)groups.For the primary outcome,123 patients in the C group achieved a gastric filling score of≥4(97.62%vs 80.16%,P<0.0001).More patients in the C group had the highest gastric filling scores within the first 5 min(78.57%vs 29.37%,P<0.0001)and 10 minutes(54.76%vs 13.49%,P<0.0001)after the capsule entered the stomach.More patients in the W group required extra liquid for gastric refilling(1.59%vs 16.67%,P<0.0001).Transpyloric passage of the capsule under magnetic control was successfully performed in 43 patients in the C group(P<0.0001),accompanied by a shorter gastric transit time(53.27±53.83 minutes vs 71.12±52.19 minutes,P=0.001).CONCLUSION Carbonated soft drinks demonstrated superior and more sustained gastric filling compared with those of water alone,with the potential to promote gastric emptying. 展开更多
关键词 magnetically controlled capsule endoscopy Gastric preparation Gastric filling Gastric emptying Carbon dioxide Clinical trial
暂未订购
RESEARCH ON DYNAMICAL BEHAVIOR AND DESIGN OF CONTROL PARAMETER FOR NONLINEAR MAGNETIC-CONTROL SYSTEM 被引量:1
5
作者 姚宏 徐健学 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 1999年第1期27-32,共6页
A dynamic model of magnetic levitation control system with nonlinear magnetic force and feedback control is presented. Because of nonlinear magnetic force, the complex dynamic behavior will be shown in the system (cod... A dynamic model of magnetic levitation control system with nonlinear magnetic force and feedback control is presented. Because of nonlinear magnetic force, the complex dynamic behavior will be shown in the system (codimension two bifurcation, Hopf bifurcation, heteroclinic bifurcation). By theoretical analysis, it is shown that the design of parameters has a close relation with the systems stability; the range of selected parameters is achieved when the controller system is stable, based on the condition of bifurcation parameters, bifurcation curve, bifurcation set and phase portraits. From the simulating of magnetic flywheel system, the complex dynamic behavior is shown, and the result is in correspondence with the theoretics. It is of great theoretic importance to improve design and stable control for the nonlinear magnetic levitation control system. 展开更多
关键词 magnetic control nonlinear systems dynamic characteristics BIFURCATION
在线阅读 下载PDF
Experimental Study on Characteristics of NiMnGa Magnetically Controlled Shape Memory Alloy 被引量:8
6
作者 Fengxiang WANG Wenjun LI Qingxin ZHANG Chenxi LI Xinjie WU 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2006年第1期55-58,共4页
The static and dynamic magnetic controlling characteristics of NiMnGa magnetically controlled shape memory alloy (MSMA) were experimentally studied. The results show that the characteristics of induced strain with r... The static and dynamic magnetic controlling characteristics of NiMnGa magnetically controlled shape memory alloy (MSMA) were experimentally studied. The results show that the characteristics of induced strain with respect to the magnetic field are nonlinear with saturation nature, and dependent on the temperature as well as the load applied to the MSMA. The magnetic shape memory effect can be observed only in complete martensite phase at room temperature. The magnetic permeability of MSMA is not constant and reduces with the increment of magnetic field. The relative saturation magnetic permeability of MSMA is about 1.5. 展开更多
关键词 NIMNGA magnetically controlled shape memory alloy CHARACTERISTICS Experimental study
在线阅读 下载PDF
Mathematical model and magnetic-control mechanism of the stability of rotating spray transfer 被引量:14
7
作者 殷树言 陈树君 +1 位作者 王军 徐鲁宁 《China Welding》 EI CAS 2003年第1期57-61,共5页
To realize stable rotating spray transfer in the region of high constant current is the key of realizing high deposition rate MAG welding process without helium in shielding gas and extending the welding current rang... To realize stable rotating spray transfer in the region of high constant current is the key of realizing high deposition rate MAG welding process without helium in shielding gas and extending the welding current range of traditional MAG welding process. In this paper, the magnetic control mechanism of the rotating spray transfer is stated and mathematical model is given. Theoretic basis is established, which implements high deposition rate MAG welding process with magnetic control instead of helium in shielding gas. 展开更多
关键词 magnetic control rotating spray transfer high deposition rates MAG welding process mathematical model
在线阅读 下载PDF
Real-time teleoperation of magnetic force-driven microrobots with a motion model and stable haptic force feedback for micromanipulation
8
作者 Yasin Cagatay Duygu Baijun Xie +2 位作者 Xiao Zhang Min Jun Kim Chung Hyuk Park 《Nanotechnology and Precision Engineering》 2025年第2期63-76,共14页
Microrobots powered by an external magnetic field could be used for sophisticated medical applications such as cell treatment,micromanipulation,and noninvasive surgery inside the body.Untethered microrobot application... Microrobots powered by an external magnetic field could be used for sophisticated medical applications such as cell treatment,micromanipulation,and noninvasive surgery inside the body.Untethered microrobot applications can benefit from haptic technology and telecommunication,enabling telemedical micro-manipulation.Users can manipulate the microrobots with haptic feedback by interacting with the robot operating system remotely in such applications.Artificially created haptic forces based on wirelessly transmitted data and model-based guidance can aid human operators with haptic sensations while manipulating microrobots.The system presented here includes a haptic device and a magnetic tweezer system linked together using a network-based teleoperation method with motion models in fluids.The magnetic microrobots can be controlled remotely,and the haptic interactions with the remote environment can be felt in real time.A time-domain passivity controller is applied to overcome network delay and ensure stability of communication.This study develops and tests a motion model for microrobots and evaluates two image-based 3D tracking algorithms to improve tracking accuracy in various Newtonian fluids.Additionally,it demonstrates that microrobots can group together to transport multiple larger objects,move through microfluidic channels for detailed tasks,and use a novel method for disassembly,greatly expanding their range of use in microscale operations.Remote medical treatment in multiple locations,remote delivery of medication without the need for physical penetration of the skin,and remotely controlled cell manipulations are some of the possible uses of the proposed technology. 展开更多
关键词 MICROROBOT magnetic control Haptic force-feedback Microrobot motion model Telemanipulation
在线阅读 下载PDF
Miniature magnetically anchored and controlled camera system for trocar-less laparoscopy 被引量:8
9
作者 ding-hui dong hao-yang zhu +5 位作者 yu luo hong-ke zhang jun-xi xiang fei xue rong-qian wu yi lv 《World Journal of Gastroenterology》 SCIE CAS 2017年第12期2168-2174,共7页
AIM To design a miniature magnetically anchored and controlled camera system to reduce the number of trocars which are required for laparoscopy.METHODS The system consists of a miniature magnetically anchored camera w... AIM To design a miniature magnetically anchored and controlled camera system to reduce the number of trocars which are required for laparoscopy.METHODS The system consists of a miniature magnetically anchored camera with a 30° downward angle, an external magnetically anchored unit, and a vision output device. The camera weighs 12 g, measures Φ10.5 mm × 55 mm and has two magnets, a vision model, a light source, and a metal hexagonal nut. To test the prototype, the camera was inserted through a 12-mm conventional trocar in an ex vivo real liver laparoscopic training system. A trocar-less laparoscopic cholecystectomy was performed 6 times using a 12-mm and a 5-mm conventional trocar. In addition, the same procedure was performed in four canine models.RESULTS Both procedures were successfully performed using only two conventional laparoscopic trocars. The cholecystectomy was completed without any major complication in 42 min(38-45 min) in vitro and in 50 min(45-53 min) using an animal model. This camera was anchored and controlled by an external unit magnetically anchored on the abdominal wall. The camera could generate excellent image. with no instrument collisions.CONCLUSION The camera system we designed provides excellent optics and can be easily maneuvered. The number of conventional trocars is reduced without adding technical difficulties. 展开更多
关键词 Trocar-less laparoscopy magnetically anchored and controlled camera Minimally invasive surgery
暂未订购
Detachable string magnetically controlled capsule endoscopy for the noninvasive diagnosis of esophageal diseases:A prospective,blind clinical study 被引量:2
10
作者 Yan-Ling Yang Huang-Wen Qin +5 位作者 Zhao-Yu Chen Hui-Ning Fan Yi Yu Wei Da Jin-Shui Zhu Jing Zhang 《World Journal of Gastroenterology》 SCIE CAS 2024年第9期1121-1131,共11页
BACKGROUND Traditional esophagogastroduodenoscopy(EGD),an invasive examination method,can cause discomfort and pain in patients.In contrast,magnetically controlled capsule endoscopy(MCE),a noninvasive method,is being ... BACKGROUND Traditional esophagogastroduodenoscopy(EGD),an invasive examination method,can cause discomfort and pain in patients.In contrast,magnetically controlled capsule endoscopy(MCE),a noninvasive method,is being applied for the detection of stomach and small intestinal diseases,but its application in treating esophageal diseases is not widespread.AIM To evaluate the safety and efficacy of detachable string MCE(ds-MCE)for the diagnosis of esophageal diseases.METHODS Fifty patients who had been diagnosed with esophageal diseases were pros-pectively recruited for this clinical study and underwent ds-MCE and conven-tional EGD.The primary endpoints included the sensitivity,specificity,positive predictive value,negative predictive value,and diagnostic accuracy of ds-MCE for patients with esophageal diseases.The secondary endpoints consisted of visualizing the esophageal and dentate lines,as well as the subjects'tolerance of the procedure.RESULTS Using EGD as the gold standard,the sensitivity,specificity,positive predictive value,negative predictive value,and diagnostic accuracy of ds-MCE for esophageal disease detection were 85.71%,86.21%,81.82%,89.29%,and 86%,respectively.ds-MCE was more comfortable and convenient than EGD was,with 80%of patients feeling that ds-MCE examination was very comfortable or comfortable and 50%of patients believing that detachable string v examination was very convenient.CONCLUSION This study revealed that ds-MCE has the same diagnostic effects as traditional EGD for esophageal diseases and is more comfortable and convenient than EGD,providing a novel noninvasive method for treating esophageal diseases. 展开更多
关键词 Clinical trial Detachable string magnetically controlled capsule endoscopy ESOPHAGOGASTRODUODENOSCOPY Noninvasive diagnosis Esophageal diseases
暂未订购
Effect of axial static magnetic field on cleanliness and microstructure in magnetically controlled electroslag remelted bearing steel 被引量:1
11
作者 Qiang Li Zhi-bin Xia +4 位作者 Yi-feng Guo Zhe Shen Tian-xiang Zheng Biao Ding Yun-bo Zhong 《Journal of Iron and Steel Research International》 SCIE EI CSCD 2021年第12期1562-1573,共12页
The effect of the axial static magnetic field(ASMF)on cleanliness and microstructure in magnetically controlled electroslag remelted GCr15 bearing steel ingots was investigated experimentally.The results show that a m... The effect of the axial static magnetic field(ASMF)on cleanliness and microstructure in magnetically controlled electroslag remelted GCr15 bearing steel ingots was investigated experimentally.The results show that a magnetically controlled spin-vibration induced by the interaction of the ASMFs and the remelting current exists at the consumable electrode tip,resulting in thinner liquid melt film and smaller droplets.With the increase in magnetic flux density,the optimization effect of ASMFs on electroslag remelting process increases and reaches the peak with a 40 mT ASMF,then decreases.The cleanliness of the ingots was improved,and the count of inclusions larger than 5μm was reduced.The microstructure of the ingots processed with a 40 mT ASMF was significantly refined.The depth of the metallic molten pool was reduced from 45.2 to 17.5 mm with the application of 40 mT ASMF.The tensile strength,impact toughness,and Rockwell hardness of the ingots obtained under the 40 mT ASMF were significantly improved.The mechanisms of the spin-vibration occurring at the electrode tip end were interpreted in detail to elucidate the effect of ASMFs. 展开更多
关键词 magnetically controlled electroslag remelting Axial static magnetic field Inclusion removal Molten pool Alternating Lorentz force CLEANLINESS GCr15 bearing steel
原文传递
Helicobacter pylori infection may result in poor gastric cleanliness in magnetically controlled capsule gastroscopy examination: A singlecenter retrospective study 被引量:1
12
作者 Jingjing Xia Jie Fang +2 位作者 Liying Chen Yange Meng Lin Su 《Laparoscopic, Endoscopic and Robotic Surgery》 2024年第4期147-154,共8页
Objective:Magnetically controlled capsule gastroscopy(MCCG)is an effective method for screening gastric diseases;however,its performance may be affected by gastric cleanliness.We aimed to explore the correlation betwe... Objective:Magnetically controlled capsule gastroscopy(MCCG)is an effective method for screening gastric diseases;however,its performance may be affected by gastric cleanliness.We aimed to explore the correlation between Helicobacter pylori infection and the degree of gastric cleanliness in the MCCG.Methods:This retrospective study enrolled 297 participants from October 2020 to April 2024 at Sir Run Run Shaw Hospital,Zhejiang University School of Medicine.Participant characteristics,MCCG examination results,and(13)C-urea breath test(C13-UBT)results were collected.The gastric cleanliness in MCCG examinations was assessed using a gastric cleanliness score.Binary logistic regression was used to analyze the relationships among participant characteristics,H.pylori infection,and gastric cleanliness.Chi-square tests and Fisher's exact tests were used to analyze the relationships among gastric lesions,H.pylori infection,and gastric cleanliness.Results:Among the participants,24.2%had H.pylori infection,and 17.5%had poor gastric cleanliness.Hypertension(odds ratio[OR]:2.63;95%confidence interval[CI]:1.36e5.09;p?0.004)was associated with a greater likelihood of H.pylori infection.H.pylori infection(OR:3.76;95%CI:1.99e7.09;p<0.001)was an independent risk factor for poor gastric cleanliness in the MCCG.A significant disparity was noted in the prevalence of focal erosions(p<0.001),gastric ulcers(p?0.001),and positive gastric lesions(p?0.027)between the 2 groups with and without H.pylori infection.The proportion of positive gastric lesions was not significantly different between the good gastric cleanliness group and the poor gastric cleanliness group(25.7%vs.21.2%;p?0.490).Conclusion:The findings of this study revealed that H.pylori infection was associated with hypertension.H.pylori infection may lead to poor gastric cleanliness.Institutions are advised to perform C13-UBT before MCCG,and participants should be informed of the risk of poor gastric cleanliness if the results are positive.The decision to perform H.pylori eradication before MCCG should take into account patient willingness and the benefit-to-risk ratio. 展开更多
关键词 Helicobacter pylori Gastric cleanliness C-urea breath test Hypertension magnetically controlled capsule gastroscopy
原文传递
Controllable Synthesis and Magnetic Properties of Monodisperse Fe_3O_4 Nanoparticles 被引量:1
13
作者 王朱良 马慧 +3 位作者 王芳 李敏 张利国 许小红 《Chinese Physics Letters》 SCIE CAS CSCD 2016年第10期107-111,共5页
Magnetite (Fe3O4) nanoparticles with different sizes and shapes are synthesized by the thermal decomposition method. Two approaches, non-injection one-pot and hot-injection methods, are designed to investigate the g... Magnetite (Fe3O4) nanoparticles with different sizes and shapes are synthesized by the thermal decomposition method. Two approaches, non-injection one-pot and hot-injection methods, are designed to investigate the growth mechanism in detail. It is found that the size and shape of nanoparticles are determined by adjusting the precursor concentration and duration time, which can be well explained by the mechanism based on the LaMer model in our synthetic system. The monodisperse Fe3O4 nanoparticles have a mean diameter from 5nm to 16nm, and shape evolution from spherical to triangular and cubic. The magnetic properties are size-dependent, and Fe3O4 nanoparticles in small size about 5 nm exhibit superparamagnetie properties at room temperature and maximum saturation magnetization approaches to 78 emu/g, whereas Fe3O4 nanoparticles develop ferromagnetic properties when the diameter increases to about 16nm. 展开更多
关键词 FE acac in IS on of controllable Synthesis and magnetic Properties of Monodisperse Fe3O4 Nanoparticles
原文传递
Research of Magnetic Bias Control System Based on STATCOM 被引量:1
14
作者 Zongqiang Zheng 《World Journal of Engineering and Technology》 2016年第3期9-15,共7页
As the most important style of reactive power compensation system, the research and design control system of static synchronous compensator (STATCOM) is an important aspect of keeping stable and normal operation. This... As the most important style of reactive power compensation system, the research and design control system of static synchronous compensator (STATCOM) is an important aspect of keeping stable and normal operation. This paper analyzes the influences of bias magnetic to STATCOM, and proposes an effective magnetic bias control method and program realization, so reduced to producing two harmonics. It improves the quality and reliability of STATCOM output voltage;Finally, the tests are conducted in the ±500 kVar STATCOM, and the results show the validity and necessity of this compensation method. 展开更多
关键词 Static Synchronous Compensator (STATCOM) magnetic Bias control Harmonic Suppression
在线阅读 下载PDF
Magnetically controlled self-sealing pressure-preserved coring technology
15
作者 Gui-Kang Liu He-Ping Xie +4 位作者 Cong Li Zhen-Xi You Xiao-Jun Shi Jian-Jun Hu Ming-Zhong Gao 《Petroleum Science》 SCIE EI CAS CSCD 2024年第5期3464-3481,共18页
Pressure-preserved coring is an effective means to develop deep resources. However, due to the complexity of existing pressure-preserved technology, the average success rate of pressure-preserved coring is low. In res... Pressure-preserved coring is an effective means to develop deep resources. However, due to the complexity of existing pressure-preserved technology, the average success rate of pressure-preserved coring is low. In response, a novel in situ magnetically controlled self-sealing pressure-preserved coring technology for deep reserves has been proposed and validated. This innovative technology distinguishes itself from conventional methods by employing noncontact forces to replace traditional pretensioning mechanisms, thereby enhancing the mechanical design of pressure-preserved coring equipment and significantly boosting the fault tolerance of the technology. Here, we report on the design,theoretical calculations, experimental validation, and industrial testing of this technology. Through theoretical and simulation calculations, the self-sealing composite magnetic field of the pressure controller was optimized. The initial pre-tensioning force of the optimal magnetic field was 13.05 N. The reliability of the magnetically controlled self-sealing pressure-preserved coring technology was verified using a self-developed self-sealing pressure performance testing platform, confirming the accuracy of the composite magnetic field calculation theory. Subsequently, a magnetically controlled self-triggering pressure-preserved coring device was designed. Field pressure-preserved coring was then conducted,preliminarily verifying the technology's effective self-sealing performance in industrial applications.Furthermore, the technology was analyzed and verified to be adaptable to complex reservoir environments with pressures up to 30 MPa, temperatures up to 80℃, and p H values ranging from 1 to 14. These research results provide technical support for multidirectional pressure-preserved coring, thus paving a new technical route for deep energy exploration through coring. 展开更多
关键词 In situ pressure-preserved coring magnetically controlled SELF-SEALING magnetic design Deep earth exploration
原文传递
Martensitic Transformation in Magnetically Controlled Shape Memory Alloys Co_(50)Ni_(20)Ga_(30)
16
作者 FanbinMENG YangxianLI +4 位作者 HeyanLIU JingpingQU MingZHANG JinglanCHEN GuanghengWU 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2004年第6期697-700,共4页
The martensitic transformation for Co50Ni20Ga30 ribbon synthesized by the melt-spinning technique was studied by means of X-ray diffraction and ac magnetic susceptibility. The Co50Ni20Ga30 ribbon, having bcc phase wit... The martensitic transformation for Co50Ni20Ga30 ribbon synthesized by the melt-spinning technique was studied by means of X-ray diffraction and ac magnetic susceptibility. The Co50Ni20Ga30 ribbon, having bcc phase with calculated lattice parameters of a=0.57431 nm at 313 K. It exhibits a structure transition from parent phase to martensite during cooling. The martensitic phase in Co50Ni20Ga30 ribbon is tetragonal structure with lattice parameters of a=b=0.5422 nm and c=0.6401 nm. (c/a>1). According to the changing of diffraction intensity for martensite and the change of ac magnetic susceptibility, the process of the martensitic transformation can be divided into three parts during cooling from 283 K to 213 K. When the temperature decreasing sequentially from 193 K to 110 K, the structure of the martensite has a change in which the a-axis decreases and c-axis increases. The morphologies of selfaccommodation were observeds. The parallelogram morphology, the diamond morphology and the fork morphology were found. 展开更多
关键词 magnetically controlled Shape memory alloys Martensitic transformation
在线阅读 下载PDF
Voltage control magnetism and ferromagnetic resonance in an Fe_(19)Ni_(81)/PMN-PT heterostructure by strain
17
作者 Jun Ren Junming Li +5 位作者 Sheng Zhang Jun Li Wenxia Su Dunhui Wang Qingqi Cao Youwei Du 《Chinese Physics B》 SCIE EI CAS CSCD 2022年第7期544-548,共5页
Voltage control magnetism has been widely studied due to its potential applications in the next generation of information technology.PMN-PT,as a single crystal ferroelectric substrate,has been widely used in the study... Voltage control magnetism has been widely studied due to its potential applications in the next generation of information technology.PMN-PT,as a single crystal ferroelectric substrate,has been widely used in the study of voltage control magnetism because of its excellent piezoelectric properties.However,most of the research based on PMN-PT only studies the influence of a single tensile(or compressive)stress on the magnetic properties due to the asymmetry of strain.In this work,we show the effect of different strains on the magnetic anisotropy of an Fe_(19)Ni_(81)/(011)PMN-PT heterojunction.More importantly,the(011)cut PMN-PT generates non-volatile strain,which provides an advantage when investigating the voltage manipulation of RF/microwave magnetic devices.As a result,a ferromagnetic resonance field tunability of 70 Oe is induced in our sample by the non-volatile strain.Our results provide new possibilities for novel voltage adjustable RF/microwave magnetic devices and spintronic devices. 展开更多
关键词 voltage control magnetism magnetoelectric coupling magnetic anisotropy ferromagnetic resonance
原文传递
Control of magnetic levitation positioning stage with an eddy current damper
18
作者 王伟明 闪明才 +1 位作者 马树元 唐水源 《Journal of Beijing Institute of Technology》 EI CAS 2012年第3期315-320,共6页
To enhance the system damping,a permanent magnet set which served as an eddy current damper was added to the magnetic levitation positioning stage which consists of a moving table,four Halbach permanent magnetic array... To enhance the system damping,a permanent magnet set which served as an eddy current damper was added to the magnetic levitation positioning stage which consists of a moving table,four Halbach permanent magnetic arrays,four stators and displacement sensors.The dynamics model of this stage was a complex nonlinear,strong coupling system which made the control strategy to be a focus research.The nonlinear controller of the system was proposed based on the theory of differential geometry.Both simulation and experimental results show that either the decoupling control of the movement can be realized in horizontal and vertical directions,and the control performance was improved by the damper,verifying the validity and efficiency of this method. 展开更多
关键词 magnetic levitation(maglev) positioning stage eddy current damper nonlinear control feedback linearization
在线阅读 下载PDF
Earth-observation satellite attitude control using passive and active hybrid magnetically suspended flywheels
19
作者 杨照华 杨宁宁 余远金 《Journal of Beijing Institute of Technology》 EI CAS 2014年第2期226-234,共9页
The control strategy is presented using passive and active hybrid magnetically suspended flywheels(P&A MSFWs),which can help meet the requirements of high precision and high stability for earth-observation satellit... The control strategy is presented using passive and active hybrid magnetically suspended flywheels(P&A MSFWs),which can help meet the requirements of high precision and high stability for earth-observation satellites.Compared with the conventional flywheel,P&A MSFW has more rotation degrees of freedom(DOFs)since the rotor is suspended by magnetic bearings,and thus requires more efficient controllers.A modified sliding mode control law(SMC)to our novel nonlinear and coupled system is presented,which is interrupted by inertia matrix uncertainties and external disturbances.SMC law via Lyapunov method is improved,and a fuzzy control scheme is used to attenuate the chatting and control attitude accuracy and maintain the robustness of SMC.Simulation results are provided to illustrate the efficiency of our model by using our control law. 展开更多
关键词 attitude control passive and active hybrid magnetically suspended flywheels(P&A MSFWs) modeling and analyzing sliding mode control(SMC) fuzzy control
在线阅读 下载PDF
Sea Turtle-inspired Magnetic Soft Robot Demonstrates Versatile Land-to-Submerged Locomotion
20
作者 Yida Guo Jia Zhu +7 位作者 Yutong Wang Lei Zhang Shichuan Wang Binhong Dou Shenghao Yang Bing Li Fuzhou Niu Chonglei Hao 《Journal of Bionic Engineering》 2025年第3期1039-1048,共10页
Soft robots capable of navigating complex environments hold promise for minimally invasive medical procedures and micromanipulation tasks.Here,we present a magnetically controlled multi-legged soft robot inspired by g... Soft robots capable of navigating complex environments hold promise for minimally invasive medical procedures and micromanipulation tasks.Here,we present a magnetically controlled multi-legged soft robot inspired by green sea turtle locomotion.Our designed robot,featuring six magnetized feet,demonstrates stable motion within a magnetic field strength range of 1.84–6.44 mT.Locomotion displacement scales linearly with field strength,while velocity correlates with frequency,reaching approximately 25 mm/s at 10 Hz.The robot navigates dry,semi-submerged,and fully submerged conditions,climbs slopes up to 30°,and maneuvers through U-shaped bends.Additionally,we demonstrate the robot's capability to smoothly transition between terrestrial and aquatic environments,demonstrating its amphibious locomotion performance.This adaptability to diverse environments,coupled with precise magnetic control,opens new possibilities for soft robotics in confined and complex spaces.Our findings provide a framework for designing highly maneuverable small-scale soft robots with potential applications ranging from targeted drug delivery to environmental sensing in challenging terrains. 展开更多
关键词 Bio-inspiration Soft robot Terrestrial-aquatic locomotion magnetically controlled robot
在线阅读 下载PDF
上一页 1 2 3 下一页 到第
使用帮助 返回顶部