The design and fabrication of anisotropic photonic crystal supraballs with multiple responses are highly desirable for versatile environmental sensing and flexible displaying.Herein,we developed an available strategy ...The design and fabrication of anisotropic photonic crystal supraballs with multiple responses are highly desirable for versatile environmental sensing and flexible displaying.Herein,we developed an available strategy to construct a series of multi-responsive magnetic colloidal photonic crystal(CPC)supraballs with Janus and molecular-analogue structures.Initially,the humidity and temperature sensitive CPC supraballs were obtained via immobilization of polyacrylamide(PAM)and polyisopropylacrylamide(PNIPAM)hydrogels into the CPC structure,respectively,and CdTe/ZnS quantum dots endow the supraballs fluorescent signal under UV light.Furthermore,Fe_(3)O_(4) nanoparticles(NPs)were served as a magnetic hemisphere to construct CPC Janus supraballs which can be subsequently assembled into three different molecular-shaped cluster particles that integrate more response types via Fe_(3)O_(4) NPs hemisphere coalescence to a magnetic coupling center,recognizing multiple responses simultaneously that correspond the environmental altering.In addition,2D polychromatic patterns with sensitive CPC pixels printed by automatic printing system were demonstrated,which could monitor the changes of temperature and humidity.The multi-responsive magnetic controlling supraballs and 2D patterns reveal the promising applications in environmental sensing,anti-counterfeiting and displaying.展开更多
The fast excitation system of a composite magnetic controllable reactor is introduced. In this excitation system, a bidirectional function (i.e. fast forward excitation and backward forcible demagnetization) is avai...The fast excitation system of a composite magnetic controllable reactor is introduced. In this excitation system, a bidirectional function (i.e. fast forward excitation and backward forcible demagnetization) is available, which can significantly improve the response speed, performances, and application scope of magnetic controllable reactor.展开更多
Inspired by bacterial motility mechanisms,Magnetic Helical Miniature Robots(MHMRs)exhibit promising applications in biomedical fields due to their efficient locomotion and compatibility with biological tissues.In this...Inspired by bacterial motility mechanisms,Magnetic Helical Miniature Robots(MHMRs)exhibit promising applications in biomedical fields due to their efficient locomotion and compatibility with biological tissues.In this review,we systematically survey the basics of MHMRs,from propulsion mechanism,magnetization and control methods to biomedical applications,aiming to provide readers with an easily understandable overview and fundamental knowledge on implementing MHMRs.The MHMRs are actuated by rotating magnetic fields,achieving steering and rotation through magnetic torque,and converting rotation into forward motion through the helical structure.Magnetization methods for MHMRs are reviewed into three types:attaching magnets,magnetic coatings,and magnetic powder doping.Additionally,this review discusses the control methods for MHMRs,covering imaging techniques,path tracking control—including classical control algorithms and increasingly popular learning-based methods,and swarm control.Subsequently,a comprehensive survey is conducted on the biomedical applications of MHMRs in the treatment of vascular diseases,drug delivery,cell delivery,and their integration with catheters.We finally provide a perspective about future challenges in MHMR research,including enhancing functional design capabilities,developing swarm-assisted independent control mechanisms,refining in vivo imaging techniques,and ensuring robust biocompatibility for safe medical use.展开更多
BACKGROUND The clinical effectiveness of magnetically controlled capsule endoscopy(MCE)is well established.However,problems,such as abdominal distension,insufficient gastric filling,and prolonged gastric retention tim...BACKGROUND The clinical effectiveness of magnetically controlled capsule endoscopy(MCE)is well established.However,problems,such as abdominal distension,insufficient gastric filling,and prolonged gastric retention time,persist with MCE gastric preparations.AIM To compare gastric filling using a carbonated soft drink with that using pure water during MCE.METHODS We performed an open-label randomised controlled trial at the Endoscopy Centre of Changhai Hospital in Shanghai.Patients aged 18-80 years,with or without gastrointestinal symptoms,scheduled for MCE were consecutively recruited.Those who provided informed consent were randomly assigned to the carbonated soft drink group(C group)or water group(W group)in a 1:1 ratio.For patients in the W group,1000 mL of water was ingested to distend the stomach,whereas for patients in the C group,550 mL of carbonated soft drink was provided,and patients were required to drink quickly while minimising burping.The primary endpoint was the number of patients with a gastric filling score of≥4 within 5 minutes after the capsule entered the stomach.RESULTS From December 3,2020 to May 17,2021,252 patients(141 men),aged 18-77 years,were assigned to the C(n=126)and W(n=126)groups.For the primary outcome,123 patients in the C group achieved a gastric filling score of≥4(97.62%vs 80.16%,P<0.0001).More patients in the C group had the highest gastric filling scores within the first 5 min(78.57%vs 29.37%,P<0.0001)and 10 minutes(54.76%vs 13.49%,P<0.0001)after the capsule entered the stomach.More patients in the W group required extra liquid for gastric refilling(1.59%vs 16.67%,P<0.0001).Transpyloric passage of the capsule under magnetic control was successfully performed in 43 patients in the C group(P<0.0001),accompanied by a shorter gastric transit time(53.27±53.83 minutes vs 71.12±52.19 minutes,P=0.001).CONCLUSION Carbonated soft drinks demonstrated superior and more sustained gastric filling compared with those of water alone,with the potential to promote gastric emptying.展开更多
A dynamic model of magnetic levitation control system with nonlinear magnetic force and feedback control is presented. Because of nonlinear magnetic force, the complex dynamic behavior will be shown in the system (cod...A dynamic model of magnetic levitation control system with nonlinear magnetic force and feedback control is presented. Because of nonlinear magnetic force, the complex dynamic behavior will be shown in the system (codimension two bifurcation, Hopf bifurcation, heteroclinic bifurcation). By theoretical analysis, it is shown that the design of parameters has a close relation with the systems stability; the range of selected parameters is achieved when the controller system is stable, based on the condition of bifurcation parameters, bifurcation curve, bifurcation set and phase portraits. From the simulating of magnetic flywheel system, the complex dynamic behavior is shown, and the result is in correspondence with the theoretics. It is of great theoretic importance to improve design and stable control for the nonlinear magnetic levitation control system.展开更多
The static and dynamic magnetic controlling characteristics of NiMnGa magnetically controlled shape memory alloy (MSMA) were experimentally studied. The results show that the characteristics of induced strain with r...The static and dynamic magnetic controlling characteristics of NiMnGa magnetically controlled shape memory alloy (MSMA) were experimentally studied. The results show that the characteristics of induced strain with respect to the magnetic field are nonlinear with saturation nature, and dependent on the temperature as well as the load applied to the MSMA. The magnetic shape memory effect can be observed only in complete martensite phase at room temperature. The magnetic permeability of MSMA is not constant and reduces with the increment of magnetic field. The relative saturation magnetic permeability of MSMA is about 1.5.展开更多
To realize stable rotating spray transfer in the region of high constant current is the key of realizing high deposition rate MAG welding process without helium in shielding gas and extending the welding current rang...To realize stable rotating spray transfer in the region of high constant current is the key of realizing high deposition rate MAG welding process without helium in shielding gas and extending the welding current range of traditional MAG welding process. In this paper, the magnetic control mechanism of the rotating spray transfer is stated and mathematical model is given. Theoretic basis is established, which implements high deposition rate MAG welding process with magnetic control instead of helium in shielding gas.展开更多
Microrobots powered by an external magnetic field could be used for sophisticated medical applications such as cell treatment,micromanipulation,and noninvasive surgery inside the body.Untethered microrobot application...Microrobots powered by an external magnetic field could be used for sophisticated medical applications such as cell treatment,micromanipulation,and noninvasive surgery inside the body.Untethered microrobot applications can benefit from haptic technology and telecommunication,enabling telemedical micro-manipulation.Users can manipulate the microrobots with haptic feedback by interacting with the robot operating system remotely in such applications.Artificially created haptic forces based on wirelessly transmitted data and model-based guidance can aid human operators with haptic sensations while manipulating microrobots.The system presented here includes a haptic device and a magnetic tweezer system linked together using a network-based teleoperation method with motion models in fluids.The magnetic microrobots can be controlled remotely,and the haptic interactions with the remote environment can be felt in real time.A time-domain passivity controller is applied to overcome network delay and ensure stability of communication.This study develops and tests a motion model for microrobots and evaluates two image-based 3D tracking algorithms to improve tracking accuracy in various Newtonian fluids.Additionally,it demonstrates that microrobots can group together to transport multiple larger objects,move through microfluidic channels for detailed tasks,and use a novel method for disassembly,greatly expanding their range of use in microscale operations.Remote medical treatment in multiple locations,remote delivery of medication without the need for physical penetration of the skin,and remotely controlled cell manipulations are some of the possible uses of the proposed technology.展开更多
AIM To design a miniature magnetically anchored and controlled camera system to reduce the number of trocars which are required for laparoscopy.METHODS The system consists of a miniature magnetically anchored camera w...AIM To design a miniature magnetically anchored and controlled camera system to reduce the number of trocars which are required for laparoscopy.METHODS The system consists of a miniature magnetically anchored camera with a 30° downward angle, an external magnetically anchored unit, and a vision output device. The camera weighs 12 g, measures Φ10.5 mm × 55 mm and has two magnets, a vision model, a light source, and a metal hexagonal nut. To test the prototype, the camera was inserted through a 12-mm conventional trocar in an ex vivo real liver laparoscopic training system. A trocar-less laparoscopic cholecystectomy was performed 6 times using a 12-mm and a 5-mm conventional trocar. In addition, the same procedure was performed in four canine models.RESULTS Both procedures were successfully performed using only two conventional laparoscopic trocars. The cholecystectomy was completed without any major complication in 42 min(38-45 min) in vitro and in 50 min(45-53 min) using an animal model. This camera was anchored and controlled by an external unit magnetically anchored on the abdominal wall. The camera could generate excellent image. with no instrument collisions.CONCLUSION The camera system we designed provides excellent optics and can be easily maneuvered. The number of conventional trocars is reduced without adding technical difficulties.展开更多
BACKGROUND Traditional esophagogastroduodenoscopy(EGD),an invasive examination method,can cause discomfort and pain in patients.In contrast,magnetically controlled capsule endoscopy(MCE),a noninvasive method,is being ...BACKGROUND Traditional esophagogastroduodenoscopy(EGD),an invasive examination method,can cause discomfort and pain in patients.In contrast,magnetically controlled capsule endoscopy(MCE),a noninvasive method,is being applied for the detection of stomach and small intestinal diseases,but its application in treating esophageal diseases is not widespread.AIM To evaluate the safety and efficacy of detachable string MCE(ds-MCE)for the diagnosis of esophageal diseases.METHODS Fifty patients who had been diagnosed with esophageal diseases were pros-pectively recruited for this clinical study and underwent ds-MCE and conven-tional EGD.The primary endpoints included the sensitivity,specificity,positive predictive value,negative predictive value,and diagnostic accuracy of ds-MCE for patients with esophageal diseases.The secondary endpoints consisted of visualizing the esophageal and dentate lines,as well as the subjects'tolerance of the procedure.RESULTS Using EGD as the gold standard,the sensitivity,specificity,positive predictive value,negative predictive value,and diagnostic accuracy of ds-MCE for esophageal disease detection were 85.71%,86.21%,81.82%,89.29%,and 86%,respectively.ds-MCE was more comfortable and convenient than EGD was,with 80%of patients feeling that ds-MCE examination was very comfortable or comfortable and 50%of patients believing that detachable string v examination was very convenient.CONCLUSION This study revealed that ds-MCE has the same diagnostic effects as traditional EGD for esophageal diseases and is more comfortable and convenient than EGD,providing a novel noninvasive method for treating esophageal diseases.展开更多
The effect of the axial static magnetic field(ASMF)on cleanliness and microstructure in magnetically controlled electroslag remelted GCr15 bearing steel ingots was investigated experimentally.The results show that a m...The effect of the axial static magnetic field(ASMF)on cleanliness and microstructure in magnetically controlled electroslag remelted GCr15 bearing steel ingots was investigated experimentally.The results show that a magnetically controlled spin-vibration induced by the interaction of the ASMFs and the remelting current exists at the consumable electrode tip,resulting in thinner liquid melt film and smaller droplets.With the increase in magnetic flux density,the optimization effect of ASMFs on electroslag remelting process increases and reaches the peak with a 40 mT ASMF,then decreases.The cleanliness of the ingots was improved,and the count of inclusions larger than 5μm was reduced.The microstructure of the ingots processed with a 40 mT ASMF was significantly refined.The depth of the metallic molten pool was reduced from 45.2 to 17.5 mm with the application of 40 mT ASMF.The tensile strength,impact toughness,and Rockwell hardness of the ingots obtained under the 40 mT ASMF were significantly improved.The mechanisms of the spin-vibration occurring at the electrode tip end were interpreted in detail to elucidate the effect of ASMFs.展开更多
Objective:Magnetically controlled capsule gastroscopy(MCCG)is an effective method for screening gastric diseases;however,its performance may be affected by gastric cleanliness.We aimed to explore the correlation betwe...Objective:Magnetically controlled capsule gastroscopy(MCCG)is an effective method for screening gastric diseases;however,its performance may be affected by gastric cleanliness.We aimed to explore the correlation between Helicobacter pylori infection and the degree of gastric cleanliness in the MCCG.Methods:This retrospective study enrolled 297 participants from October 2020 to April 2024 at Sir Run Run Shaw Hospital,Zhejiang University School of Medicine.Participant characteristics,MCCG examination results,and(13)C-urea breath test(C13-UBT)results were collected.The gastric cleanliness in MCCG examinations was assessed using a gastric cleanliness score.Binary logistic regression was used to analyze the relationships among participant characteristics,H.pylori infection,and gastric cleanliness.Chi-square tests and Fisher's exact tests were used to analyze the relationships among gastric lesions,H.pylori infection,and gastric cleanliness.Results:Among the participants,24.2%had H.pylori infection,and 17.5%had poor gastric cleanliness.Hypertension(odds ratio[OR]:2.63;95%confidence interval[CI]:1.36e5.09;p?0.004)was associated with a greater likelihood of H.pylori infection.H.pylori infection(OR:3.76;95%CI:1.99e7.09;p<0.001)was an independent risk factor for poor gastric cleanliness in the MCCG.A significant disparity was noted in the prevalence of focal erosions(p<0.001),gastric ulcers(p?0.001),and positive gastric lesions(p?0.027)between the 2 groups with and without H.pylori infection.The proportion of positive gastric lesions was not significantly different between the good gastric cleanliness group and the poor gastric cleanliness group(25.7%vs.21.2%;p?0.490).Conclusion:The findings of this study revealed that H.pylori infection was associated with hypertension.H.pylori infection may lead to poor gastric cleanliness.Institutions are advised to perform C13-UBT before MCCG,and participants should be informed of the risk of poor gastric cleanliness if the results are positive.The decision to perform H.pylori eradication before MCCG should take into account patient willingness and the benefit-to-risk ratio.展开更多
Magnetite (Fe3O4) nanoparticles with different sizes and shapes are synthesized by the thermal decomposition method. Two approaches, non-injection one-pot and hot-injection methods, are designed to investigate the g...Magnetite (Fe3O4) nanoparticles with different sizes and shapes are synthesized by the thermal decomposition method. Two approaches, non-injection one-pot and hot-injection methods, are designed to investigate the growth mechanism in detail. It is found that the size and shape of nanoparticles are determined by adjusting the precursor concentration and duration time, which can be well explained by the mechanism based on the LaMer model in our synthetic system. The monodisperse Fe3O4 nanoparticles have a mean diameter from 5nm to 16nm, and shape evolution from spherical to triangular and cubic. The magnetic properties are size-dependent, and Fe3O4 nanoparticles in small size about 5 nm exhibit superparamagnetie properties at room temperature and maximum saturation magnetization approaches to 78 emu/g, whereas Fe3O4 nanoparticles develop ferromagnetic properties when the diameter increases to about 16nm.展开更多
As the most important style of reactive power compensation system, the research and design control system of static synchronous compensator (STATCOM) is an important aspect of keeping stable and normal operation. This...As the most important style of reactive power compensation system, the research and design control system of static synchronous compensator (STATCOM) is an important aspect of keeping stable and normal operation. This paper analyzes the influences of bias magnetic to STATCOM, and proposes an effective magnetic bias control method and program realization, so reduced to producing two harmonics. It improves the quality and reliability of STATCOM output voltage;Finally, the tests are conducted in the ±500 kVar STATCOM, and the results show the validity and necessity of this compensation method.展开更多
Pressure-preserved coring is an effective means to develop deep resources. However, due to the complexity of existing pressure-preserved technology, the average success rate of pressure-preserved coring is low. In res...Pressure-preserved coring is an effective means to develop deep resources. However, due to the complexity of existing pressure-preserved technology, the average success rate of pressure-preserved coring is low. In response, a novel in situ magnetically controlled self-sealing pressure-preserved coring technology for deep reserves has been proposed and validated. This innovative technology distinguishes itself from conventional methods by employing noncontact forces to replace traditional pretensioning mechanisms, thereby enhancing the mechanical design of pressure-preserved coring equipment and significantly boosting the fault tolerance of the technology. Here, we report on the design,theoretical calculations, experimental validation, and industrial testing of this technology. Through theoretical and simulation calculations, the self-sealing composite magnetic field of the pressure controller was optimized. The initial pre-tensioning force of the optimal magnetic field was 13.05 N. The reliability of the magnetically controlled self-sealing pressure-preserved coring technology was verified using a self-developed self-sealing pressure performance testing platform, confirming the accuracy of the composite magnetic field calculation theory. Subsequently, a magnetically controlled self-triggering pressure-preserved coring device was designed. Field pressure-preserved coring was then conducted,preliminarily verifying the technology's effective self-sealing performance in industrial applications.Furthermore, the technology was analyzed and verified to be adaptable to complex reservoir environments with pressures up to 30 MPa, temperatures up to 80℃, and p H values ranging from 1 to 14. These research results provide technical support for multidirectional pressure-preserved coring, thus paving a new technical route for deep energy exploration through coring.展开更多
The martensitic transformation for Co50Ni20Ga30 ribbon synthesized by the melt-spinning technique was studied by means of X-ray diffraction and ac magnetic susceptibility. The Co50Ni20Ga30 ribbon, having bcc phase wit...The martensitic transformation for Co50Ni20Ga30 ribbon synthesized by the melt-spinning technique was studied by means of X-ray diffraction and ac magnetic susceptibility. The Co50Ni20Ga30 ribbon, having bcc phase with calculated lattice parameters of a=0.57431 nm at 313 K. It exhibits a structure transition from parent phase to martensite during cooling. The martensitic phase in Co50Ni20Ga30 ribbon is tetragonal structure with lattice parameters of a=b=0.5422 nm and c=0.6401 nm. (c/a>1). According to the changing of diffraction intensity for martensite and the change of ac magnetic susceptibility, the process of the martensitic transformation can be divided into three parts during cooling from 283 K to 213 K. When the temperature decreasing sequentially from 193 K to 110 K, the structure of the martensite has a change in which the a-axis decreases and c-axis increases. The morphologies of selfaccommodation were observeds. The parallelogram morphology, the diamond morphology and the fork morphology were found.展开更多
Voltage control magnetism has been widely studied due to its potential applications in the next generation of information technology.PMN-PT,as a single crystal ferroelectric substrate,has been widely used in the study...Voltage control magnetism has been widely studied due to its potential applications in the next generation of information technology.PMN-PT,as a single crystal ferroelectric substrate,has been widely used in the study of voltage control magnetism because of its excellent piezoelectric properties.However,most of the research based on PMN-PT only studies the influence of a single tensile(or compressive)stress on the magnetic properties due to the asymmetry of strain.In this work,we show the effect of different strains on the magnetic anisotropy of an Fe_(19)Ni_(81)/(011)PMN-PT heterojunction.More importantly,the(011)cut PMN-PT generates non-volatile strain,which provides an advantage when investigating the voltage manipulation of RF/microwave magnetic devices.As a result,a ferromagnetic resonance field tunability of 70 Oe is induced in our sample by the non-volatile strain.Our results provide new possibilities for novel voltage adjustable RF/microwave magnetic devices and spintronic devices.展开更多
To enhance the system damping,a permanent magnet set which served as an eddy current damper was added to the magnetic levitation positioning stage which consists of a moving table,four Halbach permanent magnetic array...To enhance the system damping,a permanent magnet set which served as an eddy current damper was added to the magnetic levitation positioning stage which consists of a moving table,four Halbach permanent magnetic arrays,four stators and displacement sensors.The dynamics model of this stage was a complex nonlinear,strong coupling system which made the control strategy to be a focus research.The nonlinear controller of the system was proposed based on the theory of differential geometry.Both simulation and experimental results show that either the decoupling control of the movement can be realized in horizontal and vertical directions,and the control performance was improved by the damper,verifying the validity and efficiency of this method.展开更多
The control strategy is presented using passive and active hybrid magnetically suspended flywheels(P&A MSFWs),which can help meet the requirements of high precision and high stability for earth-observation satellit...The control strategy is presented using passive and active hybrid magnetically suspended flywheels(P&A MSFWs),which can help meet the requirements of high precision and high stability for earth-observation satellites.Compared with the conventional flywheel,P&A MSFW has more rotation degrees of freedom(DOFs)since the rotor is suspended by magnetic bearings,and thus requires more efficient controllers.A modified sliding mode control law(SMC)to our novel nonlinear and coupled system is presented,which is interrupted by inertia matrix uncertainties and external disturbances.SMC law via Lyapunov method is improved,and a fuzzy control scheme is used to attenuate the chatting and control attitude accuracy and maintain the robustness of SMC.Simulation results are provided to illustrate the efficiency of our model by using our control law.展开更多
Soft robots capable of navigating complex environments hold promise for minimally invasive medical procedures and micromanipulation tasks.Here,we present a magnetically controlled multi-legged soft robot inspired by g...Soft robots capable of navigating complex environments hold promise for minimally invasive medical procedures and micromanipulation tasks.Here,we present a magnetically controlled multi-legged soft robot inspired by green sea turtle locomotion.Our designed robot,featuring six magnetized feet,demonstrates stable motion within a magnetic field strength range of 1.84–6.44 mT.Locomotion displacement scales linearly with field strength,while velocity correlates with frequency,reaching approximately 25 mm/s at 10 Hz.The robot navigates dry,semi-submerged,and fully submerged conditions,climbs slopes up to 30°,and maneuvers through U-shaped bends.Additionally,we demonstrate the robot's capability to smoothly transition between terrestrial and aquatic environments,demonstrating its amphibious locomotion performance.This adaptability to diverse environments,coupled with precise magnetic control,opens new possibilities for soft robotics in confined and complex spaces.Our findings provide a framework for designing highly maneuverable small-scale soft robots with potential applications ranging from targeted drug delivery to environmental sensing in challenging terrains.展开更多
基金This work was supported by National Natural Science Foundation of China(21736006,21908103,21908104,81671390)Natural Science Foundation of Jiangsu Province(BK20190672,BK20190673,BK20201254)+2 种基金China Postdoctoral Science Foundation(2018M642235)Fund of State Key Laboratory of MaterialsOriented Chemical Engineering(ZK201704,ZK201810,KL20-10)Priority Academic Program Development of Jiangsu Higher Education Institutions(PAPD)。
文摘The design and fabrication of anisotropic photonic crystal supraballs with multiple responses are highly desirable for versatile environmental sensing and flexible displaying.Herein,we developed an available strategy to construct a series of multi-responsive magnetic colloidal photonic crystal(CPC)supraballs with Janus and molecular-analogue structures.Initially,the humidity and temperature sensitive CPC supraballs were obtained via immobilization of polyacrylamide(PAM)and polyisopropylacrylamide(PNIPAM)hydrogels into the CPC structure,respectively,and CdTe/ZnS quantum dots endow the supraballs fluorescent signal under UV light.Furthermore,Fe_(3)O_(4) nanoparticles(NPs)were served as a magnetic hemisphere to construct CPC Janus supraballs which can be subsequently assembled into three different molecular-shaped cluster particles that integrate more response types via Fe_(3)O_(4) NPs hemisphere coalescence to a magnetic coupling center,recognizing multiple responses simultaneously that correspond the environmental altering.In addition,2D polychromatic patterns with sensitive CPC pixels printed by automatic printing system were demonstrated,which could monitor the changes of temperature and humidity.The multi-responsive magnetic controlling supraballs and 2D patterns reveal the promising applications in environmental sensing,anti-counterfeiting and displaying.
文摘The fast excitation system of a composite magnetic controllable reactor is introduced. In this excitation system, a bidirectional function (i.e. fast forward excitation and backward forcible demagnetization) is available, which can significantly improve the response speed, performances, and application scope of magnetic controllable reactor.
基金the financial support from the Research Institute for Advanced Manufacturing(RIAM)of The Hong Kong Polytechnic University(project Nos.1-CD9F and 1-CDK3)the Research Grants Council(RGC)of Hong Kong(project Nos.25200424 and 15206223)+2 种基金the GuangDong Basic and Applied Basic Research Foundation(project No.2023A1515110709)the Startup fund(project No.1-BE9L)of the Hong Kong Polytechnic Universitysupported by grant from the Research Committee of the Hong Kong Polytechnic University under student account code RN5Y.
文摘Inspired by bacterial motility mechanisms,Magnetic Helical Miniature Robots(MHMRs)exhibit promising applications in biomedical fields due to their efficient locomotion and compatibility with biological tissues.In this review,we systematically survey the basics of MHMRs,from propulsion mechanism,magnetization and control methods to biomedical applications,aiming to provide readers with an easily understandable overview and fundamental knowledge on implementing MHMRs.The MHMRs are actuated by rotating magnetic fields,achieving steering and rotation through magnetic torque,and converting rotation into forward motion through the helical structure.Magnetization methods for MHMRs are reviewed into three types:attaching magnets,magnetic coatings,and magnetic powder doping.Additionally,this review discusses the control methods for MHMRs,covering imaging techniques,path tracking control—including classical control algorithms and increasingly popular learning-based methods,and swarm control.Subsequently,a comprehensive survey is conducted on the biomedical applications of MHMRs in the treatment of vascular diseases,drug delivery,cell delivery,and their integration with catheters.We finally provide a perspective about future challenges in MHMR research,including enhancing functional design capabilities,developing swarm-assisted independent control mechanisms,refining in vivo imaging techniques,and ensuring robust biocompatibility for safe medical use.
基金Supported by Shanghai Municipal Hospital Emerging Frontier Technology Joint Project,No.SHDC12019105Shanghai Science and Technology Development Funds,No.24YF2758200National Natural Science Foundation of China,No.82100699.
文摘BACKGROUND The clinical effectiveness of magnetically controlled capsule endoscopy(MCE)is well established.However,problems,such as abdominal distension,insufficient gastric filling,and prolonged gastric retention time,persist with MCE gastric preparations.AIM To compare gastric filling using a carbonated soft drink with that using pure water during MCE.METHODS We performed an open-label randomised controlled trial at the Endoscopy Centre of Changhai Hospital in Shanghai.Patients aged 18-80 years,with or without gastrointestinal symptoms,scheduled for MCE were consecutively recruited.Those who provided informed consent were randomly assigned to the carbonated soft drink group(C group)or water group(W group)in a 1:1 ratio.For patients in the W group,1000 mL of water was ingested to distend the stomach,whereas for patients in the C group,550 mL of carbonated soft drink was provided,and patients were required to drink quickly while minimising burping.The primary endpoint was the number of patients with a gastric filling score of≥4 within 5 minutes after the capsule entered the stomach.RESULTS From December 3,2020 to May 17,2021,252 patients(141 men),aged 18-77 years,were assigned to the C(n=126)and W(n=126)groups.For the primary outcome,123 patients in the C group achieved a gastric filling score of≥4(97.62%vs 80.16%,P<0.0001).More patients in the C group had the highest gastric filling scores within the first 5 min(78.57%vs 29.37%,P<0.0001)and 10 minutes(54.76%vs 13.49%,P<0.0001)after the capsule entered the stomach.More patients in the W group required extra liquid for gastric refilling(1.59%vs 16.67%,P<0.0001).Transpyloric passage of the capsule under magnetic control was successfully performed in 43 patients in the C group(P<0.0001),accompanied by a shorter gastric transit time(53.27±53.83 minutes vs 71.12±52.19 minutes,P=0.001).CONCLUSION Carbonated soft drinks demonstrated superior and more sustained gastric filling compared with those of water alone,with the potential to promote gastric emptying.
文摘A dynamic model of magnetic levitation control system with nonlinear magnetic force and feedback control is presented. Because of nonlinear magnetic force, the complex dynamic behavior will be shown in the system (codimension two bifurcation, Hopf bifurcation, heteroclinic bifurcation). By theoretical analysis, it is shown that the design of parameters has a close relation with the systems stability; the range of selected parameters is achieved when the controller system is stable, based on the condition of bifurcation parameters, bifurcation curve, bifurcation set and phase portraits. From the simulating of magnetic flywheel system, the complex dynamic behavior is shown, and the result is in correspondence with the theoretics. It is of great theoretic importance to improve design and stable control for the nonlinear magnetic levitation control system.
基金This work was supported by the National Natural Science Foundation of China under grant No.50177019by the Education Department of China under grant No.20040142004.
文摘The static and dynamic magnetic controlling characteristics of NiMnGa magnetically controlled shape memory alloy (MSMA) were experimentally studied. The results show that the characteristics of induced strain with respect to the magnetic field are nonlinear with saturation nature, and dependent on the temperature as well as the load applied to the MSMA. The magnetic shape memory effect can be observed only in complete martensite phase at room temperature. The magnetic permeability of MSMA is not constant and reduces with the increment of magnetic field. The relative saturation magnetic permeability of MSMA is about 1.5.
文摘To realize stable rotating spray transfer in the region of high constant current is the key of realizing high deposition rate MAG welding process without helium in shielding gas and extending the welding current range of traditional MAG welding process. In this paper, the magnetic control mechanism of the rotating spray transfer is stated and mathematical model is given. Theoretic basis is established, which implements high deposition rate MAG welding process with magnetic control instead of helium in shielding gas.
基金supported by National Science Foundation Grant No.2123824.
文摘Microrobots powered by an external magnetic field could be used for sophisticated medical applications such as cell treatment,micromanipulation,and noninvasive surgery inside the body.Untethered microrobot applications can benefit from haptic technology and telecommunication,enabling telemedical micro-manipulation.Users can manipulate the microrobots with haptic feedback by interacting with the robot operating system remotely in such applications.Artificially created haptic forces based on wirelessly transmitted data and model-based guidance can aid human operators with haptic sensations while manipulating microrobots.The system presented here includes a haptic device and a magnetic tweezer system linked together using a network-based teleoperation method with motion models in fluids.The magnetic microrobots can be controlled remotely,and the haptic interactions with the remote environment can be felt in real time.A time-domain passivity controller is applied to overcome network delay and ensure stability of communication.This study develops and tests a motion model for microrobots and evaluates two image-based 3D tracking algorithms to improve tracking accuracy in various Newtonian fluids.Additionally,it demonstrates that microrobots can group together to transport multiple larger objects,move through microfluidic channels for detailed tasks,and use a novel method for disassembly,greatly expanding their range of use in microscale operations.Remote medical treatment in multiple locations,remote delivery of medication without the need for physical penetration of the skin,and remotely controlled cell manipulations are some of the possible uses of the proposed technology.
基金Supported by National Natural Science Foundation of China(Major Instrumental Program)No.81127005the Science and Technology Innovation Project of Shaanxi Province,China,No.S2016TNGY0119
文摘AIM To design a miniature magnetically anchored and controlled camera system to reduce the number of trocars which are required for laparoscopy.METHODS The system consists of a miniature magnetically anchored camera with a 30° downward angle, an external magnetically anchored unit, and a vision output device. The camera weighs 12 g, measures Φ10.5 mm × 55 mm and has two magnets, a vision model, a light source, and a metal hexagonal nut. To test the prototype, the camera was inserted through a 12-mm conventional trocar in an ex vivo real liver laparoscopic training system. A trocar-less laparoscopic cholecystectomy was performed 6 times using a 12-mm and a 5-mm conventional trocar. In addition, the same procedure was performed in four canine models.RESULTS Both procedures were successfully performed using only two conventional laparoscopic trocars. The cholecystectomy was completed without any major complication in 42 min(38-45 min) in vitro and in 50 min(45-53 min) using an animal model. This camera was anchored and controlled by an external unit magnetically anchored on the abdominal wall. The camera could generate excellent image. with no instrument collisions.CONCLUSION The camera system we designed provides excellent optics and can be easily maneuvered. The number of conventional trocars is reduced without adding technical difficulties.
基金the Science and Technology Commission of Shanghai,No.18DZ1930309.
文摘BACKGROUND Traditional esophagogastroduodenoscopy(EGD),an invasive examination method,can cause discomfort and pain in patients.In contrast,magnetically controlled capsule endoscopy(MCE),a noninvasive method,is being applied for the detection of stomach and small intestinal diseases,but its application in treating esophageal diseases is not widespread.AIM To evaluate the safety and efficacy of detachable string MCE(ds-MCE)for the diagnosis of esophageal diseases.METHODS Fifty patients who had been diagnosed with esophageal diseases were pros-pectively recruited for this clinical study and underwent ds-MCE and conven-tional EGD.The primary endpoints included the sensitivity,specificity,positive predictive value,negative predictive value,and diagnostic accuracy of ds-MCE for patients with esophageal diseases.The secondary endpoints consisted of visualizing the esophageal and dentate lines,as well as the subjects'tolerance of the procedure.RESULTS Using EGD as the gold standard,the sensitivity,specificity,positive predictive value,negative predictive value,and diagnostic accuracy of ds-MCE for esophageal disease detection were 85.71%,86.21%,81.82%,89.29%,and 86%,respectively.ds-MCE was more comfortable and convenient than EGD was,with 80%of patients feeling that ds-MCE examination was very comfortable or comfortable and 50%of patients believing that detachable string v examination was very convenient.CONCLUSION This study revealed that ds-MCE has the same diagnostic effects as traditional EGD for esophageal diseases and is more comfortable and convenient than EGD,providing a novel noninvasive method for treating esophageal diseases.
基金This work is supported by the National Key Research and Development Program of China under Grant numbers of 2016YFB0300401,2018YFF0109404,and 2016YFB0301401the National Natural Science Foundation of China under Grant numbers of U1860202,U1732276,50134010,51704193,51904184,and 52004156the Users with Excellence Program of Hefei Science Center CAS under Grant number of 2019HSC-UE010,and the Changjiang Scholar Program of Chinese Ministry of Education.
文摘The effect of the axial static magnetic field(ASMF)on cleanliness and microstructure in magnetically controlled electroslag remelted GCr15 bearing steel ingots was investigated experimentally.The results show that a magnetically controlled spin-vibration induced by the interaction of the ASMFs and the remelting current exists at the consumable electrode tip,resulting in thinner liquid melt film and smaller droplets.With the increase in magnetic flux density,the optimization effect of ASMFs on electroslag remelting process increases and reaches the peak with a 40 mT ASMF,then decreases.The cleanliness of the ingots was improved,and the count of inclusions larger than 5μm was reduced.The microstructure of the ingots processed with a 40 mT ASMF was significantly refined.The depth of the metallic molten pool was reduced from 45.2 to 17.5 mm with the application of 40 mT ASMF.The tensile strength,impact toughness,and Rockwell hardness of the ingots obtained under the 40 mT ASMF were significantly improved.The mechanisms of the spin-vibration occurring at the electrode tip end were interpreted in detail to elucidate the effect of ASMFs.
基金supported by the General Research Project of the Department of Education of Zhejiang Province,China(No.Y202351338)the Soft Science Project of the Department of Science and Technology of Zhejiang Province,China(No.2024C35054).
文摘Objective:Magnetically controlled capsule gastroscopy(MCCG)is an effective method for screening gastric diseases;however,its performance may be affected by gastric cleanliness.We aimed to explore the correlation between Helicobacter pylori infection and the degree of gastric cleanliness in the MCCG.Methods:This retrospective study enrolled 297 participants from October 2020 to April 2024 at Sir Run Run Shaw Hospital,Zhejiang University School of Medicine.Participant characteristics,MCCG examination results,and(13)C-urea breath test(C13-UBT)results were collected.The gastric cleanliness in MCCG examinations was assessed using a gastric cleanliness score.Binary logistic regression was used to analyze the relationships among participant characteristics,H.pylori infection,and gastric cleanliness.Chi-square tests and Fisher's exact tests were used to analyze the relationships among gastric lesions,H.pylori infection,and gastric cleanliness.Results:Among the participants,24.2%had H.pylori infection,and 17.5%had poor gastric cleanliness.Hypertension(odds ratio[OR]:2.63;95%confidence interval[CI]:1.36e5.09;p?0.004)was associated with a greater likelihood of H.pylori infection.H.pylori infection(OR:3.76;95%CI:1.99e7.09;p<0.001)was an independent risk factor for poor gastric cleanliness in the MCCG.A significant disparity was noted in the prevalence of focal erosions(p<0.001),gastric ulcers(p?0.001),and positive gastric lesions(p?0.027)between the 2 groups with and without H.pylori infection.The proportion of positive gastric lesions was not significantly different between the good gastric cleanliness group and the poor gastric cleanliness group(25.7%vs.21.2%;p?0.490).Conclusion:The findings of this study revealed that H.pylori infection was associated with hypertension.H.pylori infection may lead to poor gastric cleanliness.Institutions are advised to perform C13-UBT before MCCG,and participants should be informed of the risk of poor gastric cleanliness if the results are positive.The decision to perform H.pylori eradication before MCCG should take into account patient willingness and the benefit-to-risk ratio.
基金Supported by the National Natural Science Foundation of China under Grant Nos 51571135,11274214 and 61434002the Special Funds of Shanxi Scholars Program under Grant No IRT1156+1 种基金Collaborative Innovation Center for Shanxi Advanced Permanent Materials and Technologythe Special Funds of the Ministry of Education of China under Grant No 20121404130001
文摘Magnetite (Fe3O4) nanoparticles with different sizes and shapes are synthesized by the thermal decomposition method. Two approaches, non-injection one-pot and hot-injection methods, are designed to investigate the growth mechanism in detail. It is found that the size and shape of nanoparticles are determined by adjusting the precursor concentration and duration time, which can be well explained by the mechanism based on the LaMer model in our synthetic system. The monodisperse Fe3O4 nanoparticles have a mean diameter from 5nm to 16nm, and shape evolution from spherical to triangular and cubic. The magnetic properties are size-dependent, and Fe3O4 nanoparticles in small size about 5 nm exhibit superparamagnetie properties at room temperature and maximum saturation magnetization approaches to 78 emu/g, whereas Fe3O4 nanoparticles develop ferromagnetic properties when the diameter increases to about 16nm.
文摘As the most important style of reactive power compensation system, the research and design control system of static synchronous compensator (STATCOM) is an important aspect of keeping stable and normal operation. This paper analyzes the influences of bias magnetic to STATCOM, and proposes an effective magnetic bias control method and program realization, so reduced to producing two harmonics. It improves the quality and reliability of STATCOM output voltage;Finally, the tests are conducted in the ±500 kVar STATCOM, and the results show the validity and necessity of this compensation method.
基金supported by the National Natural Science Foundation of China (52225403, 52304146)the Sichuan Science and Technology Program (2023NSFSC0919, 2023NSFSC0790)the China Postdoctoral Science Foundation (2023M742460)。
文摘Pressure-preserved coring is an effective means to develop deep resources. However, due to the complexity of existing pressure-preserved technology, the average success rate of pressure-preserved coring is low. In response, a novel in situ magnetically controlled self-sealing pressure-preserved coring technology for deep reserves has been proposed and validated. This innovative technology distinguishes itself from conventional methods by employing noncontact forces to replace traditional pretensioning mechanisms, thereby enhancing the mechanical design of pressure-preserved coring equipment and significantly boosting the fault tolerance of the technology. Here, we report on the design,theoretical calculations, experimental validation, and industrial testing of this technology. Through theoretical and simulation calculations, the self-sealing composite magnetic field of the pressure controller was optimized. The initial pre-tensioning force of the optimal magnetic field was 13.05 N. The reliability of the magnetically controlled self-sealing pressure-preserved coring technology was verified using a self-developed self-sealing pressure performance testing platform, confirming the accuracy of the composite magnetic field calculation theory. Subsequently, a magnetically controlled self-triggering pressure-preserved coring device was designed. Field pressure-preserved coring was then conducted,preliminarily verifying the technology's effective self-sealing performance in industrial applications.Furthermore, the technology was analyzed and verified to be adaptable to complex reservoir environments with pressures up to 30 MPa, temperatures up to 80℃, and p H values ranging from 1 to 14. These research results provide technical support for multidirectional pressure-preserved coring, thus paving a new technical route for deep energy exploration through coring.
基金This study was supported by the National Natural Science Foundation of China grant No.50271023 the Natural Science Foundation of Hebei Province(No.503031).
文摘The martensitic transformation for Co50Ni20Ga30 ribbon synthesized by the melt-spinning technique was studied by means of X-ray diffraction and ac magnetic susceptibility. The Co50Ni20Ga30 ribbon, having bcc phase with calculated lattice parameters of a=0.57431 nm at 313 K. It exhibits a structure transition from parent phase to martensite during cooling. The martensitic phase in Co50Ni20Ga30 ribbon is tetragonal structure with lattice parameters of a=b=0.5422 nm and c=0.6401 nm. (c/a>1). According to the changing of diffraction intensity for martensite and the change of ac magnetic susceptibility, the process of the martensitic transformation can be divided into three parts during cooling from 283 K to 213 K. When the temperature decreasing sequentially from 193 K to 110 K, the structure of the martensite has a change in which the a-axis decreases and c-axis increases. The morphologies of selfaccommodation were observeds. The parallelogram morphology, the diamond morphology and the fork morphology were found.
文摘Voltage control magnetism has been widely studied due to its potential applications in the next generation of information technology.PMN-PT,as a single crystal ferroelectric substrate,has been widely used in the study of voltage control magnetism because of its excellent piezoelectric properties.However,most of the research based on PMN-PT only studies the influence of a single tensile(or compressive)stress on the magnetic properties due to the asymmetry of strain.In this work,we show the effect of different strains on the magnetic anisotropy of an Fe_(19)Ni_(81)/(011)PMN-PT heterojunction.More importantly,the(011)cut PMN-PT generates non-volatile strain,which provides an advantage when investigating the voltage manipulation of RF/microwave magnetic devices.As a result,a ferromagnetic resonance field tunability of 70 Oe is induced in our sample by the non-volatile strain.Our results provide new possibilities for novel voltage adjustable RF/microwave magnetic devices and spintronic devices.
基金Supported by the National Natural Science Foundation of China (60674052)
文摘To enhance the system damping,a permanent magnet set which served as an eddy current damper was added to the magnetic levitation positioning stage which consists of a moving table,four Halbach permanent magnetic arrays,four stators and displacement sensors.The dynamics model of this stage was a complex nonlinear,strong coupling system which made the control strategy to be a focus research.The nonlinear controller of the system was proposed based on the theory of differential geometry.Both simulation and experimental results show that either the decoupling control of the movement can be realized in horizontal and vertical directions,and the control performance was improved by the damper,verifying the validity and efficiency of this method.
文摘The control strategy is presented using passive and active hybrid magnetically suspended flywheels(P&A MSFWs),which can help meet the requirements of high precision and high stability for earth-observation satellites.Compared with the conventional flywheel,P&A MSFW has more rotation degrees of freedom(DOFs)since the rotor is suspended by magnetic bearings,and thus requires more efficient controllers.A modified sliding mode control law(SMC)to our novel nonlinear and coupled system is presented,which is interrupted by inertia matrix uncertainties and external disturbances.SMC law via Lyapunov method is improved,and a fuzzy control scheme is used to attenuate the chatting and control attitude accuracy and maintain the robustness of SMC.Simulation results are provided to illustrate the efficiency of our model by using our control law.
基金supported by Shenzhen Science and Technology Program(nos.JCYJ20210324132810026,GXWD20220811164014001 and KQTD20210811090146075)the National Natural Science Foundation of China(no.52375175)+3 种基金Guangdong Basic and Applied Basic Research Foundation(no.2024A1515240015)Jiangsu Provincial Outstanding Youth Program(no.BK20230072)Suzhou Industrial Foresight and Key Core Technology Project(no.SYC2022044)grants from Jiangsu QingLan Project and Jiangsu 333 high-level talents.
文摘Soft robots capable of navigating complex environments hold promise for minimally invasive medical procedures and micromanipulation tasks.Here,we present a magnetically controlled multi-legged soft robot inspired by green sea turtle locomotion.Our designed robot,featuring six magnetized feet,demonstrates stable motion within a magnetic field strength range of 1.84–6.44 mT.Locomotion displacement scales linearly with field strength,while velocity correlates with frequency,reaching approximately 25 mm/s at 10 Hz.The robot navigates dry,semi-submerged,and fully submerged conditions,climbs slopes up to 30°,and maneuvers through U-shaped bends.Additionally,we demonstrate the robot's capability to smoothly transition between terrestrial and aquatic environments,demonstrating its amphibious locomotion performance.This adaptability to diverse environments,coupled with precise magnetic control,opens new possibilities for soft robotics in confined and complex spaces.Our findings provide a framework for designing highly maneuverable small-scale soft robots with potential applications ranging from targeted drug delivery to environmental sensing in challenging terrains.