According to Ref.[1],four kinds of new magnet-sensitive solid-state transducers have been developed with new elements (magnetic diode couple and magnetic transistor). They are (1) single magnetic transistor transducer...According to Ref.[1],four kinds of new magnet-sensitive solid-state transducers have been developed with new elements (magnetic diode couple and magnetic transistor). They are (1) single magnetic transistor transducer,(2) magnetic diode couple transducer, (3) magnetic diode and magnetic transistor combined transducer and (4) bridge circuit of double magnetic diode couple transducer.Their practical circuits are introduced in this paper.Their performances are tested experimentally and compared in the form of experimental curves and empirical formulas.These four transducers are superior to the transducers given in Ref.[4-7] in multifunction and universality,especially in the ability to measure very low speed.展开更多
Microcapsules consisting of human serum albumin, magnetite and a prototype drug (5-fluroouracil) are obtained from emulsion by heat-stabilization. The most probable diametre of the magnet-sensitive microcapsules is 0....Microcapsules consisting of human serum albumin, magnetite and a prototype drug (5-fluroouracil) are obtained from emulsion by heat-stabilization. The most probable diametre of the magnet-sensitive microcapsules is 0.15 pm. The microcapsules satisfy the requirement of the magnetic carrier of drugs for the use of injection from the view points of size and shape. Flowing in an aqueous suspension, the microcapsules can be retained easily by the control of a magnetic field. The drug can be released gradually from the microcapsules when they are in physiological saline. The microcapsules prepared at the stabilization temperature of 200C have the least variable of permeation property. A structure model of the microcapsules has been proposed.展开更多
文摘According to Ref.[1],four kinds of new magnet-sensitive solid-state transducers have been developed with new elements (magnetic diode couple and magnetic transistor). They are (1) single magnetic transistor transducer,(2) magnetic diode couple transducer, (3) magnetic diode and magnetic transistor combined transducer and (4) bridge circuit of double magnetic diode couple transducer.Their practical circuits are introduced in this paper.Their performances are tested experimentally and compared in the form of experimental curves and empirical formulas.These four transducers are superior to the transducers given in Ref.[4-7] in multifunction and universality,especially in the ability to measure very low speed.
文摘Microcapsules consisting of human serum albumin, magnetite and a prototype drug (5-fluroouracil) are obtained from emulsion by heat-stabilization. The most probable diametre of the magnet-sensitive microcapsules is 0.15 pm. The microcapsules satisfy the requirement of the magnetic carrier of drugs for the use of injection from the view points of size and shape. Flowing in an aqueous suspension, the microcapsules can be retained easily by the control of a magnetic field. The drug can be released gradually from the microcapsules when they are in physiological saline. The microcapsules prepared at the stabilization temperature of 200C have the least variable of permeation property. A structure model of the microcapsules has been proposed.