This paper investigates the detection and mitigation of coordinated cyberattacks on Load Frequency Control(LFC)systems integrated with Battery Energy Storage Systems(BESS).As renewable energy sources gain greater pene...This paper investigates the detection and mitigation of coordinated cyberattacks on Load Frequency Control(LFC)systems integrated with Battery Energy Storage Systems(BESS).As renewable energy sources gain greater penetration,power grids are becoming increasingly vulnerable to cyber threats,potentially leading to frequency instability and widespread disruptions.We model two significant attack vectors:load-altering attacks(LAAs)and false data injection attacks(FDIAs)that corrupt frequency measurements.These are analyzed for their impact on grid frequency stability in both linear and nonlinear LFC models,incorporating generation rate constraints and nonlinear loads.A coordinated attack strategy is presented,combining LAAs and FDIAs to achieve stealthiness by concealing frequency deviations from system operators,thereby maximizing disruption while evading traditional detection.To counteract these threats,we propose an Unknown Input Observer(UIO)-based detection framework for linear and nonlinear LFCs.The UIO is designed using linear matrix inequalities(LMIs)to estimate system states while isolating unknown attack inputs,enabling attack detection through monitoring measurement residuals against a predefined threshold.For mitigation,we leverage BESS capabilities with two adaptive strategies:dynamic mitigation for dynamic LAAs,which tunes BESS parameters to enhance the system’s stability margin and accelerate convergence to equilibrium;and staticmitigation for static LAAs and FDIAs.Simulations show that the UIO achieves high detection accuracy,with residuals exceeding thresholds promptly under coordinated attacks,even in nonlinear models.Mitigation strategies reduce frequency deviations by up to 80%compared to unmitigated cases,restoring stability within seconds.展开更多
Load frequency control(LFC)is a critical function to balance the power consumption and generation.Thegrid frequency is a crucial indicator for maintaining balance.However,the widely used information and communication ...Load frequency control(LFC)is a critical function to balance the power consumption and generation.Thegrid frequency is a crucial indicator for maintaining balance.However,the widely used information and communication infrastructure for LFC increases the risk of being attacked by malicious actors.The dynamic load altering attack(DLAA)is a typical attack that can destabilize the power system,causing the grid frequency to deviate fromits nominal value.Therefore,in this paper,we mathematically analyze the impact of DLAA on the stability of the grid frequency and propose the network parameter regulation(NPR)to mitigate the impact.To begin with,the dynamic LFC model is constructed by highlighting the importance of the network parameter.Then,we model the DLAA and analyze its impact on LFC using the theory of second-order dynamic systems.Finally,we model the NPR and prove its effect in mitigating the DLAA.Besides,we construct a least-effort NPR considering its infrastructure cost and aim to reduce the operation cost.Finally,we carry out extensive simulations to demonstrate the impact of the DLAA and evaluate the mitigation performance of NPR.The proposed cost-benefit NPR approach can not only mitigate the impact of DLAA with 100%and also save 41.18$/MWh in terms of the operation cost.展开更多
Nanotechnology has provided thousands of novel nano-antimicrobials possessing features uncommon in clinically available antimicrobials.Here,nanocarriers loaded with conventional antimicrobials and responding to enviro...Nanotechnology has provided thousands of novel nano-antimicrobials possessing features uncommon in clinically available antimicrobials.Here,nanocarriers loaded with conventional antimicrobials and responding to environmental changes upon entry into oral biofilms are reviewed.Supra-gingival biofilms are characterized by acidic pH,the presence of bacterial enzymes,and the development of hypoxia in deeper layers.Sub-gingival biofilms are slightly alkaline,with hypoxia occurring over their entire depth.Upon entering biofilms,negatively charged,pH-and/or hypoxia-responsive nanocarriers become positively charged.This charge reversal leads to electrostatic double-layer attraction between positively charged nanocarriers towards negatively charged,waterfilled channel walls in biofilms,enhancing their accumulation in a biofilm.Degradation of bacterial enzyme-responsive nanocarriers causes in-biofilm release of antimicrobial cargo,yielding higher local antimicrobial concentrations than can be achieved through their direct,oral administration without harming soft tissues.Enhanced antibiofilm activity after in-biofilm antimicrobial release from biofilm-responsive micelles and liposomes has been demonstrated in vitro towards single-species Streptococcus mutans and Staphylococcus aureus biofilms or in vivo using specific-pathogen-free rodents inoculated with selected pathogens.This preferential antibacterial activity regulated the microbial composition of ex vivo human oral biofilm towards a more healthy microbiome composition.Although clinical confirmation is limited,the potential benefits of stimuli-responsive,antimicrobial-loaded nanocarriers for oral biofilm control and microbiome restoration are worth further investigation towards clinical translation.展开更多
To mitigate the challenges in managing the damage level of reinforced concrete(RC)pier columns subjected to cyclic reverse loading,this study conducted a series of cyclic reverse tests on RC pier columns.By analyzing ...To mitigate the challenges in managing the damage level of reinforced concrete(RC)pier columns subjected to cyclic reverse loading,this study conducted a series of cyclic reverse tests on RC pier columns.By analyzing the outcomes of destructive testing on various specimens and fine-tuning the results with the aid of the IMK(Ibarra Medina Krawinkler)recovery model,the energy dissipation capacity coefficient of the pier columns were able to be determined.Furthermore,utilizing the calibrated damage model parameters,the damage index for each specimen were calculated.Based on the obtained damage levels,three distinct pre-damage conditions were designed for the pier columns:minor damage,moderate damage,and severe damage.The study then predicted the variations in hysteresis curves and damage indices under cyclic loading conditions.The experimental findings reveal that the displacement at the top of the pier columns can serve as a reliable indicator for controlling the damage level of pier columns post-loading.Moreover,the calibrated damage index model exhibits proficiency in accurately predicting the damage level of RC pier columns under cyclic loading.展开更多
Background Interconnection of different power systems has a major effect on system stability.This study aims to design an optimal load frequency control(LFC)system based on a proportional-integral(PI)controller for a ...Background Interconnection of different power systems has a major effect on system stability.This study aims to design an optimal load frequency control(LFC)system based on a proportional-integral(PI)controller for a two-area power system.Methods Two areas were connected through an AC tie line in parallel with a DC link to stabilize the frequency of oscillations in both areas.The PI parameters were tuned using the cuckoo search algorithm(CSA)to minimize the integral absolute error(IAE).A state matrix was provided,and the stability of the system was verified by calculating the eigenvalues.The frequency response was investigated for load variation,changes in the generator rate constraint,the turbine time constant,and the governor time constant.Results The CSA was compared with particle swarm optimization algorithm(PSO)under identical conditions.The system was modeled based on a state-space mathematical representation and simulated using MATLAB.The results demonstrated the effectiveness of the proposed controller based on both algorithms and,it is clear that CSA is superior to PSO.Conclusion The CSA algorithm smoothens the system response,reduces ripples,decreases overshooting and settling time,and improves the overall system performance under different disturbances.展开更多
As the development of new power systems progresses,the inherent inertia of power systems continues to diminish.Centralized frequency regulation,which relies on rapid communication and real-time control,can enable inve...As the development of new power systems progresses,the inherent inertia of power systems continues to diminish.Centralized frequency regulation,which relies on rapid communication and real-time control,can enable inverter-based thermostatically controlled load(ITCL)clusters to provide virtual inertia support to the power grid.However,ITCL clusters exhibit significant discrete response characteristics,which precludes the direct integration of load-side inertia support into the synchronous unit side.To address this issue,this paper elaborates on the existing technical framework and analyzes the underlying causes of the problem.It proposes a timestamp allocation mechanism for ITCL cluster control instructions,ensuring that many ITCL terminals can be triggered at staggered times,thereby allowing the load cluster power to adhere to the inertia analog control law at any moment.Building on this foundation,the paper further examines the impact of the inertia response delay of ITCL clusters,which is based on centralized frequency regulation,on the stability of the power system.A design scheme for inertia analog control parameters is proposed,taking into account dual constraints,frequency stability and load cluster regulation capacity.Finally,the feasibility and applicability of the proposed mechanism and parameter design scheme are investigated through simulations conducted via MATLAB/Simulink.展开更多
This study develops a GWO-optimized cascaded fuzzy-PID controller with triangular membership functions for load frequency control in interconnected power systems.The controller’s effectiveness is demonstrated on ther...This study develops a GWO-optimized cascaded fuzzy-PID controller with triangular membership functions for load frequency control in interconnected power systems.The controller’s effectiveness is demonstrated on thermal–thermal and hybrid thermal–hydro–gas power systems.The controller parameters were tuned using the Integral Time Absolute Error(ITAE)objective function,which was also evaluated alongside other objective functions(IAE,ISE,and ITSE)to ensure high precision in frequency stabilization.To validate the effectiveness of the triangular membership function,comparisons were made with fuzzy-PID controllers employing trapezoidal and Gaussian membership functions.Performance metrics,including ITAE,settling time,overshoot,and undershoot of frequency deviation,as well as tie-line power deviation,were evaluated.Robustness was established through a comprehensive sensitivity analysis with T_(G),T_(T),andT_(R) parameter variations(±50%),a non-linearity analysis incorporating Generation Rate Constraint(GRC)and Governor Deadband(GDB),a random Step Load Perturbation(SLP)over 0–100 s,and also Stability analysis of the proposed scheme is conducted using multiple approaches,including frequency-domain analysis,Lyapunov stability theory,and eigenvalue analysis.Additionally,the system incorporating thermal,hydro,and gas turbines,along with advanced components like CES and HVDC links,was analysed.Comparisons were conducted against controllers optimized using Modified Grasshopper Optimization Algorithm(MGOA),Honey Badger Algorithm(HBA),Particle Swarm Optimization(PSO),Artificial Bee Colony(ABC),and Spider Monkey Optimization(SMO)algorithms.Results demonstrate that the GWO-based fuzzy-PID controller outperforms the alternatives,exhibiting superior performance across all evaluated metrics.This highlights the potential of the proposed approach as a robust solution for load frequency control in complex and dynamic power systems.展开更多
This paper solves the problem of model-free dual-arm space robot maneuvering after non-cooperative target capture under high control quality requirements.The explicit system model is unavailable,and the maneuvering mi...This paper solves the problem of model-free dual-arm space robot maneuvering after non-cooperative target capture under high control quality requirements.The explicit system model is unavailable,and the maneuvering mission is disturbed by the measurement noise and the target adversarial behavior.To address these problems,a model-free Combined Adaptive-length Datadriven Predictive Controller(CADPC)is proposed.It consists of a separated subsystem identification method and a combined predictive control strategy.The subsystem identification method is composed of an adaptive data length,thereby reducing sensitivity to undetermined measurement noises and disturbances.Based on the subsystem identification,the combined predictive controller is established,reducing calculating resource.The stability of the CADPC is rigorously proven using the Input-to-State Stable(ISS)theorem and the small-gain theorem.Simulations demonstrate that CADPC effectively handles the model-free space robot post operation in the presence of significant disturbances,state measurement noise,and control input errors.It achieves improved steady-state accuracy,reduced steady-state control consumption,and minimized control input chattering.展开更多
We used hydrodynamic simulations and shock wave propagation theories to analyze the behavior of shock waves within Ti/Pt periodically modulated graded structures and their integration layers.The effects of the total n...We used hydrodynamic simulations and shock wave propagation theories to analyze the behavior of shock waves within Ti/Pt periodically modulated graded structures and their integration layers.The effects of the total number of periodic layers,the total thickness of graded materials and loading velocity on the integration layer thickness and behavior of pressure-strain rate were systematically investigated.The results reveal that,by adjusting the total number of periodically modulated layers,the total thickness of graded materials and loading velocity the pressure amplitudes of the reflected compressive and rarefaction waves at different interfaces of Ti/Pt periodically modulated graded materials can be precisely controlled.Furthermore,empirical structural design criteria for Ti/Pt periodically modulated graded materials are established.The thickness ratio variation between adjacent Ti/Pt layers in the periodic structure must exceed 0.32.After the collaborative design of the integration layer,Ti/Pt periodically modulated graded materials can achieve a controllable loading function with pressures ranging from 1.4 to 144 GPa and strain rates from 3.8×10^(4) to 1.7×10^(7) s^(–1).The outcomes of this research provide a theoretical and simulation basis for the optimized design of periodically modulated graded materials to be utilized in ramp compression experiments.展开更多
In contemporary power systems,delving into the flexible regulation potential of demand-side resources is of paramount significance for the efficient operation of power grids.This research puts forward an innovative mu...In contemporary power systems,delving into the flexible regulation potential of demand-side resources is of paramount significance for the efficient operation of power grids.This research puts forward an innovative multivariate flexible load aggregation control approach that takes dynamic demand response into full consideration.In the initial stage,using generalized time-domain aggregation modelling for a wide array of heterogeneous flexible loads,including temperature-controlled loads,electric vehicles,and energy storage devices,a novel calculation method for their maximum adjustable capacities is devised.Distinct from conventional methods,this newly developed approach enables more precise and adaptable quantification of the load-adjusting capabilities,thereby enhancing the accuracy and flexibility of demand-side resource management.Subsequently,an SSA-BiLSTM flexible load classification prediction model is established.This model represents an innovative application in the field,effectively combining the advantages of the Sparrow Search Algorithm(SSA)and the Bidirectional Long-Short-Term Memory(BiLSTM)neural network.Furthermore,a parallel Markov chain is introduced to evaluate the switching state transfer probability of flexible loads accurately.This integration allows for a more refined determination of the maximum response capacity range of the flexible load aggregator,significantly improving the precision of capacity assessment compared to existing methods.Finally,in consonance with the intra-day scheduling plan,a newly developed diffuse filling algorithm is implemented to control the activation times of flexible loads precisely,thus achieving real-time dynamic demand response.Through in-depth case analysis and comprehensive comparative studies,the effectiveness of the proposed method is convincingly validated.With its innovative techniques and enhanced performance,it is demonstrated that this method has the potential to substantially enhance the utilization efficiency of demand-side resources in power systems,providing a novel and effective solution for optimizing power grid operation and demand-side management.展开更多
Steady speed control of agricultural machinery can improve operating quality and efficiency.To address the impact of farmland slope variations on the speed stability of unmanned operation agricultural machinery,a hybr...Steady speed control of agricultural machinery can improve operating quality and efficiency.To address the impact of farmland slope variations on the speed stability of unmanned operation agricultural machinery,a hybrid control method was proposed.This method included a hybrid controller composed of a slope-based controller and a proportional-integral-derivative(PID)controller.The speed of agricultural machinery was influenced by longitudinal forces,which were divided into two parts:one part was slope-related forces and conventional resistance,and the other was hard-to-estimate forces,such as sliding friction.For the first part,a slope-based controller was designed;for the second part,a PID controller was implemented.By combining these two controllers,the system can dynamically adjust the throttle opening and the brake master cylinder pressure,ensuring steady speed travel on sloping farmland.Simulation tests at a target speed of 7 km/h demonstrated that the proposed controller maintained a stable speed,achieving a root mean square error of 0.13 km/h and a mean absolute percentage error of 1.6%.Field tests on a practical experimental platform validated the method’s effectiveness,with results showing consistent control performance across varying slope conditions.The proposed controller demonstrated superior control performance.Experimental data verified that this method can achieve precise control of the agricultural machinery’s movement speed,meeting the stability requirements for agricultural operations.展开更多
This study investigates prescribed-time position tracking control for electromagnetic satellite formations subject to model uncertainties and external disturbances.Using the Clohessy-Wiltshire equations as the relativ...This study investigates prescribed-time position tracking control for electromagnetic satellite formations subject to model uncertainties and external disturbances.Using the Clohessy-Wiltshire equations as the relative motion dynamics model,a prescribed time output feedback control strategy is proposed.A prescribed-time extended state observer is designed to estimate the relative velocity and external disturbances.The disturbance estimates are then used as the feedforward component of the controller.Building on this framework,a novel prescribed-time active disturbance rejection control strategy for position tracking is developed via a backstepping control design.The convergence of the extended state observer and the stability of the closed-loop system are rigorously analyzed using Lyapunov stability theory.Numerical simulations are performed to validate the effectiveness of the proposed controller.展开更多
Aiming at the challenge of complex load balancing coordination for a three-phase four-leg(3P4L)based multi-ended low voltage flexible DC distribution system(M-LVDC)considering unbalanced power compensation,this paper ...Aiming at the challenge of complex load balancing coordination for a three-phase four-leg(3P4L)based multi-ended low voltage flexible DC distribution system(M-LVDC)considering unbalanced power compensation,this paper proposes a phase-split power decoupling unbalanced compensation strategy based load balancing strategy for 3P4L based M-LVDC.Firstly,the topology and operation principle of the 3P4L-based M-LVDC system is introduced,and quasi-proportional resonant(QPR)based phase-split power current control for the 3P4L converter is proposed.Secondly,a load-balancing control strategy considering unbalanced compensation for 3P4L-based MLVDC is presented,in which the control diagrams for each 3P4L-based converter are detailed.The core idea of the proposed strategy is to comprehensively consider the imbalance compensation and load rate balancing between the two areas to calculate the split-phase power and current reference values of each 3P4L converter and achieve the static error-free tracking of the reference values through the QPR current inner-loop control.These reference values are then tracked with zero steady-state error using QPR current inner-loop control.Finally,the effectiveness of the proposed control strategy is verified through a 3P4L M-LVDC case study conducted on the PSCAD/EMTDC software.Theresults indicate that the proposed method not only can reduce the three-phase imbalance degrees from>20% to<0.5%,but also achieve excellent balanced load rates,with the load-rate difference smaller than 1.5%.展开更多
This study presents the use of an innovative population-based algorithm called the Sine Cosine Algorithm and its metaheuristic form,Quasi Oppositional Sine Cosine Algorithm,to automatic generation control of a multipl...This study presents the use of an innovative population-based algorithm called the Sine Cosine Algorithm and its metaheuristic form,Quasi Oppositional Sine Cosine Algorithm,to automatic generation control of a multiple-source-based interconnected power system that consists of thermal,gas,and hydro power plants.The Proportional-Integral-Derivative controller,which is utilized for automated generation control in an interconnected hybrid power systemwith aDClink connecting two regions,has been tuned using the proposed optimization technique.An Electric Vehicle is taken into consideration only as an electrical load.The Quasi Oppositional Sine Cosinemethod’s performance and efficacy have been compared to the Sine Cosine Algorithm and optimal output feedback controller tuning performance.Applying the QOSCA optimization technique,which has only been shown in this study in the context of an LFC research thus far,makes this paper unique.The main objective has been used to assess and compare the dynamic performances of the recommended controller along with QOSCA optimisation technic.The resilience of the controller is examined using two different system parameters:B(frequency bias parameter)and R(governor speed regulation).The sensitivity analysis results demonstrate the high reliability of the QOSCA algorithm-based controller.Once optimal controller gains are established for nominal conditions,step load perturbations up to±10%&±25%in the nominal values of the systemparameters and operational load condition do not require adjustment of the controller.Ultimately,a scenario is examined whereby EVs are used for area 1,and a single PID controller is used rather than three.展开更多
This article investigates the robust current tracking control problem of three-phase grid-connected inverters with LCL filter under external disturbance by a dynamic state feedback control method.First,this paper cons...This article investigates the robust current tracking control problem of three-phase grid-connected inverters with LCL filter under external disturbance by a dynamic state feedback control method.First,this paper constructs an internal model to learn the information of the states and input of the grid-connected inverter under steady state.Second,by utilizing the internal model principle,the paper turns the tracking control problem into the robust stabilization control problem based on some appropriate coordinate transformations.Then,The paper designs a dynamics state feedback control law to deal with this robust stabilization problem,and thus the solution of the robust current tracking control problem of three-phase grid-connected inverters can be obtained.This control method can ensure the asymptotic stability of the closedloop system.Finally,the paper illustrates the effectiveness of the proposed control approach through several groups of simulations,and compares it with the feedforward control method to verify the robustness of the proposed control method to uncertain parameters.展开更多
Aiming to solve the steering instability and hysteresis of agricultural robots in the process of movement,a fusion PID control method of particle swarm optimization(PSO)and genetic algorithm(GA)was proposed.The fusion...Aiming to solve the steering instability and hysteresis of agricultural robots in the process of movement,a fusion PID control method of particle swarm optimization(PSO)and genetic algorithm(GA)was proposed.The fusion algorithm took advantage of the fast optimization ability of PSO to optimize the population screening link of GA.The Simulink simulation results showed that the convergence of the fitness function of the fusion algorithm was accelerated,the system response adjustment time was reduced,and the overshoot was almost zero.Then the algorithm was applied to the steering test of agricultural robot in various scenes.After modeling the steering system of agricultural robot,the steering test results in the unloaded suspended state showed that the PID control based on fusion algorithm reduced the rise time,response adjustment time and overshoot of the system,and improved the response speed and stability of the system,compared with the artificial trial and error PID control and the PID control based on GA.The actual road steering test results showed that the PID control response rise time based on the fusion algorithm was the shortest,about 4.43 s.When the target pulse number was set to 100,the actual mean value in the steady-state regulation stage was about 102.9,which was the closest to the target value among the three control methods,and the overshoot was reduced at the same time.The steering test results under various scene states showed that the PID control based on the proposed fusion algorithm had good anti-interference ability,it can adapt to the changes of environment and load and improve the performance of the control system.It was effective in the steering control of agricultural robot.This method can provide a reference for the precise steering control of other robots.展开更多
Mode shift is a special mechanism for a power-split hybrid electric vehicle(HEV)to realise electrically variable transmission,but the sudden change of equivalent inertia caused by topological configuration recombinati...Mode shift is a special mechanism for a power-split hybrid electric vehicle(HEV)to realise electrically variable transmission,but the sudden change of equivalent inertia caused by topological configuration recombination during mode shift induces a significant torque shock.Therefore,a smooth transient process,among other concerns,typically associated with this category of vehicles,is of great importance.The present research aims to introduce a novel control strategy to manage the dynamic torque of multiple power sources and therefore im-prove ride comfort.To this end,a dynamic model of the objective power-split HEV is first built.To resolve the contention between vehicle jerk and clutch friction loss,a model predictive control(MPC)combined with control allocation(CA)is then designed for the clutch-engaged phase.To reduce the torque fluctuation caused by the inertia torques of multiple power sources,a dynamic compensation control strategy(DCcs)that coordinates motorgenerator torque to compensate for the transition torque is proposed for the brake-disengaged phase.Finally,the proposed control strategy is validated by simulation and bench test,and results show great potential in reducing shift duration,torque variation,vehicle jerk and friction loss(the simulation results show decreases of 22%,39%,83%and 53%,and the experimental results show decreases of 21%,74%,77%,and 59%,re-spectively),thereby improving shift quality.展开更多
To solve the problem of in-flight actuator faults and parameter uncertainties for multiple Unmanned Aerial Vehicles(UAVs),and reduce the communication and computational resource consumption of multiple UAVs,a Fraction...To solve the problem of in-flight actuator faults and parameter uncertainties for multiple Unmanned Aerial Vehicles(UAVs),and reduce the communication and computational resource consumption of multiple UAVs,a Fraction-Order(FO)sliding-mode Fault-Tolerant Cooperative Control(FTCC)strategy is proposed for multiple UAVs based on Event-Triggered Communication Mechanism(ET-COM-M)and Event-Triggered Control Mechanism(ET-CON-M).First,by considering the limited communication bandwidth of multiple UAVs in formation,an ET-COM-M is designed to significantly reduce communication times.Then,a distributed observer is skillfully constructed to estimate the reference signals for follower UAVs.Moreover,the adaptive strategy is incorporated into the Radial Basis Function Neural Network(RBFNN)to learn the lumped unknown terms for handling bias actuator faults and parameter uncertainties.Besides,the Nussbaum method is used to deal with the loss-of-effectiveness faults.To further achieve the refined control performance against faults,FO calculus is artfully integrated into the sliding-mode control protocol with ET-CON-M.Finally,Zeno behavior is excluded by rigorous theoretical analysis and Lyapunov stability is proved to show the effectiveness of the designed FTCC strategy.Simulation results show that the designed FTCC strategy with Event-Triggered Mechanism(ETM)can guarantee the safety of multiple UAVs and simultaneously reduce the communication and control frequencies,making the developed control scheme applicable in engineering.展开更多
In this paper,we consider the maximal positive definite solution of the nonlinear matrix equation.By using the idea of Algorithm 2.1 in ZHANG(2013),a new inversion-free method with a stepsize parameter is proposed to ...In this paper,we consider the maximal positive definite solution of the nonlinear matrix equation.By using the idea of Algorithm 2.1 in ZHANG(2013),a new inversion-free method with a stepsize parameter is proposed to obtain the maximal positive definite solution of nonlinear matrix equation X+A^(*)X|^(-α)A=Q with the case 0<α≤1.Based on this method,a new iterative algorithm is developed,and its convergence proof is given.Finally,two numerical examples are provided to show the effectiveness of the proposed method.展开更多
As an important resource in data link,time slots should be strategically allocated to enhance transmission efficiency and resist eavesdropping,especially considering the tremendous increase in the number of nodes and ...As an important resource in data link,time slots should be strategically allocated to enhance transmission efficiency and resist eavesdropping,especially considering the tremendous increase in the number of nodes and diverse communication needs.It is crucial to design control sequences with robust randomness and conflict-freeness to properly address differentiated access control in data link.In this paper,we propose a hierarchical access control scheme based on control sequences to achieve high utilization of time slots and differentiated access control.A theoretical bound of the hierarchical control sequence set is derived to characterize the constraints on the parameters of the sequence set.Moreover,two classes of optimal hierarchical control sequence sets satisfying the theoretical bound are constructed,both of which enable the scheme to achieve maximum utilization of time slots.Compared with the fixed time slot allocation scheme,our scheme reduces the symbol error rate by up to 9%,which indicates a significant improvement in anti-interference and eavesdropping capabilities.展开更多
基金supported by the Natural Science Foundation of China No.62303126the project Major Scientific and Technological Special Project of Guizhou Province([2024]014).
文摘This paper investigates the detection and mitigation of coordinated cyberattacks on Load Frequency Control(LFC)systems integrated with Battery Energy Storage Systems(BESS).As renewable energy sources gain greater penetration,power grids are becoming increasingly vulnerable to cyber threats,potentially leading to frequency instability and widespread disruptions.We model two significant attack vectors:load-altering attacks(LAAs)and false data injection attacks(FDIAs)that corrupt frequency measurements.These are analyzed for their impact on grid frequency stability in both linear and nonlinear LFC models,incorporating generation rate constraints and nonlinear loads.A coordinated attack strategy is presented,combining LAAs and FDIAs to achieve stealthiness by concealing frequency deviations from system operators,thereby maximizing disruption while evading traditional detection.To counteract these threats,we propose an Unknown Input Observer(UIO)-based detection framework for linear and nonlinear LFCs.The UIO is designed using linear matrix inequalities(LMIs)to estimate system states while isolating unknown attack inputs,enabling attack detection through monitoring measurement residuals against a predefined threshold.For mitigation,we leverage BESS capabilities with two adaptive strategies:dynamic mitigation for dynamic LAAs,which tunes BESS parameters to enhance the system’s stability margin and accelerate convergence to equilibrium;and staticmitigation for static LAAs and FDIAs.Simulations show that the UIO achieves high detection accuracy,with residuals exceeding thresholds promptly under coordinated attacks,even in nonlinear models.Mitigation strategies reduce frequency deviations by up to 80%compared to unmitigated cases,restoring stability within seconds.
基金supported by the project Major Scientific and Technological Special Project of Guizhou Province([2024]014).
文摘Load frequency control(LFC)is a critical function to balance the power consumption and generation.Thegrid frequency is a crucial indicator for maintaining balance.However,the widely used information and communication infrastructure for LFC increases the risk of being attacked by malicious actors.The dynamic load altering attack(DLAA)is a typical attack that can destabilize the power system,causing the grid frequency to deviate fromits nominal value.Therefore,in this paper,we mathematically analyze the impact of DLAA on the stability of the grid frequency and propose the network parameter regulation(NPR)to mitigate the impact.To begin with,the dynamic LFC model is constructed by highlighting the importance of the network parameter.Then,we model the DLAA and analyze its impact on LFC using the theory of second-order dynamic systems.Finally,we model the NPR and prove its effect in mitigating the DLAA.Besides,we construct a least-effort NPR considering its infrastructure cost and aim to reduce the operation cost.Finally,we carry out extensive simulations to demonstrate the impact of the DLAA and evaluate the mitigation performance of NPR.The proposed cost-benefit NPR approach can not only mitigate the impact of DLAA with 100%and also save 41.18$/MWh in terms of the operation cost.
基金supported by the National Science Fund for Excellent Young Scholars (32322044)the CQMU Program for Youth Innovation in Future Medicine (W0077)+1 种基金the Program for Scientific and Technological Innovation Leader of Chongqing (CQYC20220303655)the Young Scientists Fund of the National Natural Science Foundation of China (82301144)。
文摘Nanotechnology has provided thousands of novel nano-antimicrobials possessing features uncommon in clinically available antimicrobials.Here,nanocarriers loaded with conventional antimicrobials and responding to environmental changes upon entry into oral biofilms are reviewed.Supra-gingival biofilms are characterized by acidic pH,the presence of bacterial enzymes,and the development of hypoxia in deeper layers.Sub-gingival biofilms are slightly alkaline,with hypoxia occurring over their entire depth.Upon entering biofilms,negatively charged,pH-and/or hypoxia-responsive nanocarriers become positively charged.This charge reversal leads to electrostatic double-layer attraction between positively charged nanocarriers towards negatively charged,waterfilled channel walls in biofilms,enhancing their accumulation in a biofilm.Degradation of bacterial enzyme-responsive nanocarriers causes in-biofilm release of antimicrobial cargo,yielding higher local antimicrobial concentrations than can be achieved through their direct,oral administration without harming soft tissues.Enhanced antibiofilm activity after in-biofilm antimicrobial release from biofilm-responsive micelles and liposomes has been demonstrated in vitro towards single-species Streptococcus mutans and Staphylococcus aureus biofilms or in vivo using specific-pathogen-free rodents inoculated with selected pathogens.This preferential antibacterial activity regulated the microbial composition of ex vivo human oral biofilm towards a more healthy microbiome composition.Although clinical confirmation is limited,the potential benefits of stimuli-responsive,antimicrobial-loaded nanocarriers for oral biofilm control and microbiome restoration are worth further investigation towards clinical translation.
基金supported by National Natural Science Foundation of China(Project No.51878156)EPC Innovation Consulting Project for Longkou Nanshan LNG Phase I Receiving Terminal(Z2000LGENT0399).
文摘To mitigate the challenges in managing the damage level of reinforced concrete(RC)pier columns subjected to cyclic reverse loading,this study conducted a series of cyclic reverse tests on RC pier columns.By analyzing the outcomes of destructive testing on various specimens and fine-tuning the results with the aid of the IMK(Ibarra Medina Krawinkler)recovery model,the energy dissipation capacity coefficient of the pier columns were able to be determined.Furthermore,utilizing the calibrated damage model parameters,the damage index for each specimen were calculated.Based on the obtained damage levels,three distinct pre-damage conditions were designed for the pier columns:minor damage,moderate damage,and severe damage.The study then predicted the variations in hysteresis curves and damage indices under cyclic loading conditions.The experimental findings reveal that the displacement at the top of the pier columns can serve as a reliable indicator for controlling the damage level of pier columns post-loading.Moreover,the calibrated damage index model exhibits proficiency in accurately predicting the damage level of RC pier columns under cyclic loading.
基金Supported by the Russian Science Foundation(Agreement 23-41-10001,https://rscf.ru/project/23-41-10001/).
文摘Background Interconnection of different power systems has a major effect on system stability.This study aims to design an optimal load frequency control(LFC)system based on a proportional-integral(PI)controller for a two-area power system.Methods Two areas were connected through an AC tie line in parallel with a DC link to stabilize the frequency of oscillations in both areas.The PI parameters were tuned using the cuckoo search algorithm(CSA)to minimize the integral absolute error(IAE).A state matrix was provided,and the stability of the system was verified by calculating the eigenvalues.The frequency response was investigated for load variation,changes in the generator rate constraint,the turbine time constant,and the governor time constant.Results The CSA was compared with particle swarm optimization algorithm(PSO)under identical conditions.The system was modeled based on a state-space mathematical representation and simulated using MATLAB.The results demonstrated the effectiveness of the proposed controller based on both algorithms and,it is clear that CSA is superior to PSO.Conclusion The CSA algorithm smoothens the system response,reduces ripples,decreases overshooting and settling time,and improves the overall system performance under different disturbances.
基金supported by the Key Scientific and Technological Projects(2024KJGG27)of Tianfu Yongxing Laboratorythe Experimental Platform Open Innovation Funding(209042025003)of Sichuan Energy Internet Research Institute,Tsinghua University.
文摘As the development of new power systems progresses,the inherent inertia of power systems continues to diminish.Centralized frequency regulation,which relies on rapid communication and real-time control,can enable inverter-based thermostatically controlled load(ITCL)clusters to provide virtual inertia support to the power grid.However,ITCL clusters exhibit significant discrete response characteristics,which precludes the direct integration of load-side inertia support into the synchronous unit side.To address this issue,this paper elaborates on the existing technical framework and analyzes the underlying causes of the problem.It proposes a timestamp allocation mechanism for ITCL cluster control instructions,ensuring that many ITCL terminals can be triggered at staggered times,thereby allowing the load cluster power to adhere to the inertia analog control law at any moment.Building on this foundation,the paper further examines the impact of the inertia response delay of ITCL clusters,which is based on centralized frequency regulation,on the stability of the power system.A design scheme for inertia analog control parameters is proposed,taking into account dual constraints,frequency stability and load cluster regulation capacity.Finally,the feasibility and applicability of the proposed mechanism and parameter design scheme are investigated through simulations conducted via MATLAB/Simulink.
文摘This study develops a GWO-optimized cascaded fuzzy-PID controller with triangular membership functions for load frequency control in interconnected power systems.The controller’s effectiveness is demonstrated on thermal–thermal and hybrid thermal–hydro–gas power systems.The controller parameters were tuned using the Integral Time Absolute Error(ITAE)objective function,which was also evaluated alongside other objective functions(IAE,ISE,and ITSE)to ensure high precision in frequency stabilization.To validate the effectiveness of the triangular membership function,comparisons were made with fuzzy-PID controllers employing trapezoidal and Gaussian membership functions.Performance metrics,including ITAE,settling time,overshoot,and undershoot of frequency deviation,as well as tie-line power deviation,were evaluated.Robustness was established through a comprehensive sensitivity analysis with T_(G),T_(T),andT_(R) parameter variations(±50%),a non-linearity analysis incorporating Generation Rate Constraint(GRC)and Governor Deadband(GDB),a random Step Load Perturbation(SLP)over 0–100 s,and also Stability analysis of the proposed scheme is conducted using multiple approaches,including frequency-domain analysis,Lyapunov stability theory,and eigenvalue analysis.Additionally,the system incorporating thermal,hydro,and gas turbines,along with advanced components like CES and HVDC links,was analysed.Comparisons were conducted against controllers optimized using Modified Grasshopper Optimization Algorithm(MGOA),Honey Badger Algorithm(HBA),Particle Swarm Optimization(PSO),Artificial Bee Colony(ABC),and Spider Monkey Optimization(SMO)algorithms.Results demonstrate that the GWO-based fuzzy-PID controller outperforms the alternatives,exhibiting superior performance across all evaluated metrics.This highlights the potential of the proposed approach as a robust solution for load frequency control in complex and dynamic power systems.
基金supported by the National Natural Science Foundation of China(No.12372045)the National Key Research and the Development Program of China(Nos.2023YFC2205900,2023YFC2205901)。
文摘This paper solves the problem of model-free dual-arm space robot maneuvering after non-cooperative target capture under high control quality requirements.The explicit system model is unavailable,and the maneuvering mission is disturbed by the measurement noise and the target adversarial behavior.To address these problems,a model-free Combined Adaptive-length Datadriven Predictive Controller(CADPC)is proposed.It consists of a separated subsystem identification method and a combined predictive control strategy.The subsystem identification method is composed of an adaptive data length,thereby reducing sensitivity to undetermined measurement noises and disturbances.Based on the subsystem identification,the combined predictive controller is established,reducing calculating resource.The stability of the CADPC is rigorously proven using the Input-to-State Stable(ISS)theorem and the small-gain theorem.Simulations demonstrate that CADPC effectively handles the model-free space robot post operation in the presence of significant disturbances,state measurement noise,and control input errors.It achieves improved steady-state accuracy,reduced steady-state control consumption,and minimized control input chattering.
基金Funded by the Guangdong Major Project of Basic and Applied Basic Research(No.2021B0301030001)the Foundation of National Key Laboratory of Shock Wave and Detonation Physics(No.JCKYS2022212004)。
文摘We used hydrodynamic simulations and shock wave propagation theories to analyze the behavior of shock waves within Ti/Pt periodically modulated graded structures and their integration layers.The effects of the total number of periodic layers,the total thickness of graded materials and loading velocity on the integration layer thickness and behavior of pressure-strain rate were systematically investigated.The results reveal that,by adjusting the total number of periodically modulated layers,the total thickness of graded materials and loading velocity the pressure amplitudes of the reflected compressive and rarefaction waves at different interfaces of Ti/Pt periodically modulated graded materials can be precisely controlled.Furthermore,empirical structural design criteria for Ti/Pt periodically modulated graded materials are established.The thickness ratio variation between adjacent Ti/Pt layers in the periodic structure must exceed 0.32.After the collaborative design of the integration layer,Ti/Pt periodically modulated graded materials can achieve a controllable loading function with pressures ranging from 1.4 to 144 GPa and strain rates from 3.8×10^(4) to 1.7×10^(7) s^(–1).The outcomes of this research provide a theoretical and simulation basis for the optimized design of periodically modulated graded materials to be utilized in ramp compression experiments.
基金the Science and Technology Project of State Grid Shanxi Electric Power Co.,Ltd.,with the project number 52051L240001.
文摘In contemporary power systems,delving into the flexible regulation potential of demand-side resources is of paramount significance for the efficient operation of power grids.This research puts forward an innovative multivariate flexible load aggregation control approach that takes dynamic demand response into full consideration.In the initial stage,using generalized time-domain aggregation modelling for a wide array of heterogeneous flexible loads,including temperature-controlled loads,electric vehicles,and energy storage devices,a novel calculation method for their maximum adjustable capacities is devised.Distinct from conventional methods,this newly developed approach enables more precise and adaptable quantification of the load-adjusting capabilities,thereby enhancing the accuracy and flexibility of demand-side resource management.Subsequently,an SSA-BiLSTM flexible load classification prediction model is established.This model represents an innovative application in the field,effectively combining the advantages of the Sparrow Search Algorithm(SSA)and the Bidirectional Long-Short-Term Memory(BiLSTM)neural network.Furthermore,a parallel Markov chain is introduced to evaluate the switching state transfer probability of flexible loads accurately.This integration allows for a more refined determination of the maximum response capacity range of the flexible load aggregator,significantly improving the precision of capacity assessment compared to existing methods.Finally,in consonance with the intra-day scheduling plan,a newly developed diffuse filling algorithm is implemented to control the activation times of flexible loads precisely,thus achieving real-time dynamic demand response.Through in-depth case analysis and comprehensive comparative studies,the effectiveness of the proposed method is convincingly validated.With its innovative techniques and enhanced performance,it is demonstrated that this method has the potential to substantially enhance the utilization efficiency of demand-side resources in power systems,providing a novel and effective solution for optimizing power grid operation and demand-side management.
文摘Steady speed control of agricultural machinery can improve operating quality and efficiency.To address the impact of farmland slope variations on the speed stability of unmanned operation agricultural machinery,a hybrid control method was proposed.This method included a hybrid controller composed of a slope-based controller and a proportional-integral-derivative(PID)controller.The speed of agricultural machinery was influenced by longitudinal forces,which were divided into two parts:one part was slope-related forces and conventional resistance,and the other was hard-to-estimate forces,such as sliding friction.For the first part,a slope-based controller was designed;for the second part,a PID controller was implemented.By combining these two controllers,the system can dynamically adjust the throttle opening and the brake master cylinder pressure,ensuring steady speed travel on sloping farmland.Simulation tests at a target speed of 7 km/h demonstrated that the proposed controller maintained a stable speed,achieving a root mean square error of 0.13 km/h and a mean absolute percentage error of 1.6%.Field tests on a practical experimental platform validated the method’s effectiveness,with results showing consistent control performance across varying slope conditions.The proposed controller demonstrated superior control performance.Experimental data verified that this method can achieve precise control of the agricultural machinery’s movement speed,meeting the stability requirements for agricultural operations.
文摘This study investigates prescribed-time position tracking control for electromagnetic satellite formations subject to model uncertainties and external disturbances.Using the Clohessy-Wiltshire equations as the relative motion dynamics model,a prescribed time output feedback control strategy is proposed.A prescribed-time extended state observer is designed to estimate the relative velocity and external disturbances.The disturbance estimates are then used as the feedforward component of the controller.Building on this framework,a novel prescribed-time active disturbance rejection control strategy for position tracking is developed via a backstepping control design.The convergence of the extended state observer and the stability of the closed-loop system are rigorously analyzed using Lyapunov stability theory.Numerical simulations are performed to validate the effectiveness of the proposed controller.
基金supported by the key technology project of China Southern Power Grid Corporation(GZKJXM20220041)partly by theNational Key Research and Development Plan(2022YFE0205300).
文摘Aiming at the challenge of complex load balancing coordination for a three-phase four-leg(3P4L)based multi-ended low voltage flexible DC distribution system(M-LVDC)considering unbalanced power compensation,this paper proposes a phase-split power decoupling unbalanced compensation strategy based load balancing strategy for 3P4L based M-LVDC.Firstly,the topology and operation principle of the 3P4L-based M-LVDC system is introduced,and quasi-proportional resonant(QPR)based phase-split power current control for the 3P4L converter is proposed.Secondly,a load-balancing control strategy considering unbalanced compensation for 3P4L-based MLVDC is presented,in which the control diagrams for each 3P4L-based converter are detailed.The core idea of the proposed strategy is to comprehensively consider the imbalance compensation and load rate balancing between the two areas to calculate the split-phase power and current reference values of each 3P4L converter and achieve the static error-free tracking of the reference values through the QPR current inner-loop control.These reference values are then tracked with zero steady-state error using QPR current inner-loop control.Finally,the effectiveness of the proposed control strategy is verified through a 3P4L M-LVDC case study conducted on the PSCAD/EMTDC software.Theresults indicate that the proposed method not only can reduce the three-phase imbalance degrees from>20% to<0.5%,but also achieve excellent balanced load rates,with the load-rate difference smaller than 1.5%.
文摘This study presents the use of an innovative population-based algorithm called the Sine Cosine Algorithm and its metaheuristic form,Quasi Oppositional Sine Cosine Algorithm,to automatic generation control of a multiple-source-based interconnected power system that consists of thermal,gas,and hydro power plants.The Proportional-Integral-Derivative controller,which is utilized for automated generation control in an interconnected hybrid power systemwith aDClink connecting two regions,has been tuned using the proposed optimization technique.An Electric Vehicle is taken into consideration only as an electrical load.The Quasi Oppositional Sine Cosinemethod’s performance and efficacy have been compared to the Sine Cosine Algorithm and optimal output feedback controller tuning performance.Applying the QOSCA optimization technique,which has only been shown in this study in the context of an LFC research thus far,makes this paper unique.The main objective has been used to assess and compare the dynamic performances of the recommended controller along with QOSCA optimisation technic.The resilience of the controller is examined using two different system parameters:B(frequency bias parameter)and R(governor speed regulation).The sensitivity analysis results demonstrate the high reliability of the QOSCA algorithm-based controller.Once optimal controller gains are established for nominal conditions,step load perturbations up to±10%&±25%in the nominal values of the systemparameters and operational load condition do not require adjustment of the controller.Ultimately,a scenario is examined whereby EVs are used for area 1,and a single PID controller is used rather than three.
基金Supported by the Fundamental Research Funds for the Central Universities(2024ZYGXZR047)the National Natural Science Foundation of China(62373156)the Guangdong Basic and Applied Basic Research Foundation(2024A1515011736)。
文摘This article investigates the robust current tracking control problem of three-phase grid-connected inverters with LCL filter under external disturbance by a dynamic state feedback control method.First,this paper constructs an internal model to learn the information of the states and input of the grid-connected inverter under steady state.Second,by utilizing the internal model principle,the paper turns the tracking control problem into the robust stabilization control problem based on some appropriate coordinate transformations.Then,The paper designs a dynamics state feedback control law to deal with this robust stabilization problem,and thus the solution of the robust current tracking control problem of three-phase grid-connected inverters can be obtained.This control method can ensure the asymptotic stability of the closedloop system.Finally,the paper illustrates the effectiveness of the proposed control approach through several groups of simulations,and compares it with the feedforward control method to verify the robustness of the proposed control method to uncertain parameters.
文摘Aiming to solve the steering instability and hysteresis of agricultural robots in the process of movement,a fusion PID control method of particle swarm optimization(PSO)and genetic algorithm(GA)was proposed.The fusion algorithm took advantage of the fast optimization ability of PSO to optimize the population screening link of GA.The Simulink simulation results showed that the convergence of the fitness function of the fusion algorithm was accelerated,the system response adjustment time was reduced,and the overshoot was almost zero.Then the algorithm was applied to the steering test of agricultural robot in various scenes.After modeling the steering system of agricultural robot,the steering test results in the unloaded suspended state showed that the PID control based on fusion algorithm reduced the rise time,response adjustment time and overshoot of the system,and improved the response speed and stability of the system,compared with the artificial trial and error PID control and the PID control based on GA.The actual road steering test results showed that the PID control response rise time based on the fusion algorithm was the shortest,about 4.43 s.When the target pulse number was set to 100,the actual mean value in the steady-state regulation stage was about 102.9,which was the closest to the target value among the three control methods,and the overshoot was reduced at the same time.The steering test results under various scene states showed that the PID control based on the proposed fusion algorithm had good anti-interference ability,it can adapt to the changes of environment and load and improve the performance of the control system.It was effective in the steering control of agricultural robot.This method can provide a reference for the precise steering control of other robots.
基金Supported by National Natural Science Foundation of China(Grant Nos.52005039,51575043,51975048,U1764257).
文摘Mode shift is a special mechanism for a power-split hybrid electric vehicle(HEV)to realise electrically variable transmission,but the sudden change of equivalent inertia caused by topological configuration recombination during mode shift induces a significant torque shock.Therefore,a smooth transient process,among other concerns,typically associated with this category of vehicles,is of great importance.The present research aims to introduce a novel control strategy to manage the dynamic torque of multiple power sources and therefore im-prove ride comfort.To this end,a dynamic model of the objective power-split HEV is first built.To resolve the contention between vehicle jerk and clutch friction loss,a model predictive control(MPC)combined with control allocation(CA)is then designed for the clutch-engaged phase.To reduce the torque fluctuation caused by the inertia torques of multiple power sources,a dynamic compensation control strategy(DCcs)that coordinates motorgenerator torque to compensate for the transition torque is proposed for the brake-disengaged phase.Finally,the proposed control strategy is validated by simulation and bench test,and results show great potential in reducing shift duration,torque variation,vehicle jerk and friction loss(the simulation results show decreases of 22%,39%,83%and 53%,and the experimental results show decreases of 21%,74%,77%,and 59%,re-spectively),thereby improving shift quality.
基金supported in part by National Natural Science Foundation of China(Nos.62373188,62003162)the Natural Science Foundation of Jiangsu Province of China(Nos.BK20240182,BK20222012)+2 种基金the Industry-University Research Innovation Foundation for the Chinese Ministry of Education(No.2021ZYA02005)the Aeronautical Science Foundation of China(Nos.20220007052003,20200007018001)the Fundamental Research Funds for the Central Universities,China(Nos.NE2024004,NI2024001)。
文摘To solve the problem of in-flight actuator faults and parameter uncertainties for multiple Unmanned Aerial Vehicles(UAVs),and reduce the communication and computational resource consumption of multiple UAVs,a Fraction-Order(FO)sliding-mode Fault-Tolerant Cooperative Control(FTCC)strategy is proposed for multiple UAVs based on Event-Triggered Communication Mechanism(ET-COM-M)and Event-Triggered Control Mechanism(ET-CON-M).First,by considering the limited communication bandwidth of multiple UAVs in formation,an ET-COM-M is designed to significantly reduce communication times.Then,a distributed observer is skillfully constructed to estimate the reference signals for follower UAVs.Moreover,the adaptive strategy is incorporated into the Radial Basis Function Neural Network(RBFNN)to learn the lumped unknown terms for handling bias actuator faults and parameter uncertainties.Besides,the Nussbaum method is used to deal with the loss-of-effectiveness faults.To further achieve the refined control performance against faults,FO calculus is artfully integrated into the sliding-mode control protocol with ET-CON-M.Finally,Zeno behavior is excluded by rigorous theoretical analysis and Lyapunov stability is proved to show the effectiveness of the designed FTCC strategy.Simulation results show that the designed FTCC strategy with Event-Triggered Mechanism(ETM)can guarantee the safety of multiple UAVs and simultaneously reduce the communication and control frequencies,making the developed control scheme applicable in engineering.
基金Supported in part by Natural Science Foundation of Guangxi(2023GXNSFAA026246)in part by the Central Government's Guide to Local Science and Technology Development Fund(GuikeZY23055044)in part by the National Natural Science Foundation of China(62363003)。
文摘In this paper,we consider the maximal positive definite solution of the nonlinear matrix equation.By using the idea of Algorithm 2.1 in ZHANG(2013),a new inversion-free method with a stepsize parameter is proposed to obtain the maximal positive definite solution of nonlinear matrix equation X+A^(*)X|^(-α)A=Q with the case 0<α≤1.Based on this method,a new iterative algorithm is developed,and its convergence proof is given.Finally,two numerical examples are provided to show the effectiveness of the proposed method.
基金supported by the National Science Foundation of China(No.62171387)the Science and Technology Program of Sichuan Province(No.2024NSFSC0468)the China Postdoctoral Science Foundation(No.2019M663475).
文摘As an important resource in data link,time slots should be strategically allocated to enhance transmission efficiency and resist eavesdropping,especially considering the tremendous increase in the number of nodes and diverse communication needs.It is crucial to design control sequences with robust randomness and conflict-freeness to properly address differentiated access control in data link.In this paper,we propose a hierarchical access control scheme based on control sequences to achieve high utilization of time slots and differentiated access control.A theoretical bound of the hierarchical control sequence set is derived to characterize the constraints on the parameters of the sequence set.Moreover,two classes of optimal hierarchical control sequence sets satisfying the theoretical bound are constructed,both of which enable the scheme to achieve maximum utilization of time slots.Compared with the fixed time slot allocation scheme,our scheme reduces the symbol error rate by up to 9%,which indicates a significant improvement in anti-interference and eavesdropping capabilities.