Background Interconnection of different power systems has a major effect on system stability.This study aims to design an optimal load frequency control(LFC)system based on a proportional-integral(PI)controller for a ...Background Interconnection of different power systems has a major effect on system stability.This study aims to design an optimal load frequency control(LFC)system based on a proportional-integral(PI)controller for a two-area power system.Methods Two areas were connected through an AC tie line in parallel with a DC link to stabilize the frequency of oscillations in both areas.The PI parameters were tuned using the cuckoo search algorithm(CSA)to minimize the integral absolute error(IAE).A state matrix was provided,and the stability of the system was verified by calculating the eigenvalues.The frequency response was investigated for load variation,changes in the generator rate constraint,the turbine time constant,and the governor time constant.Results The CSA was compared with particle swarm optimization algorithm(PSO)under identical conditions.The system was modeled based on a state-space mathematical representation and simulated using MATLAB.The results demonstrated the effectiveness of the proposed controller based on both algorithms and,it is clear that CSA is superior to PSO.Conclusion The CSA algorithm smoothens the system response,reduces ripples,decreases overshooting and settling time,and improves the overall system performance under different disturbances.展开更多
As the development of new power systems progresses,the inherent inertia of power systems continues to diminish.Centralized frequency regulation,which relies on rapid communication and real-time control,can enable inve...As the development of new power systems progresses,the inherent inertia of power systems continues to diminish.Centralized frequency regulation,which relies on rapid communication and real-time control,can enable inverter-based thermostatically controlled load(ITCL)clusters to provide virtual inertia support to the power grid.However,ITCL clusters exhibit significant discrete response characteristics,which precludes the direct integration of load-side inertia support into the synchronous unit side.To address this issue,this paper elaborates on the existing technical framework and analyzes the underlying causes of the problem.It proposes a timestamp allocation mechanism for ITCL cluster control instructions,ensuring that many ITCL terminals can be triggered at staggered times,thereby allowing the load cluster power to adhere to the inertia analog control law at any moment.Building on this foundation,the paper further examines the impact of the inertia response delay of ITCL clusters,which is based on centralized frequency regulation,on the stability of the power system.A design scheme for inertia analog control parameters is proposed,taking into account dual constraints,frequency stability and load cluster regulation capacity.Finally,the feasibility and applicability of the proposed mechanism and parameter design scheme are investigated through simulations conducted via MATLAB/Simulink.展开更多
This study develops a GWO-optimized cascaded fuzzy-PID controller with triangular membership functions for load frequency control in interconnected power systems.The controller’s effectiveness is demonstrated on ther...This study develops a GWO-optimized cascaded fuzzy-PID controller with triangular membership functions for load frequency control in interconnected power systems.The controller’s effectiveness is demonstrated on thermal–thermal and hybrid thermal–hydro–gas power systems.The controller parameters were tuned using the Integral Time Absolute Error(ITAE)objective function,which was also evaluated alongside other objective functions(IAE,ISE,and ITSE)to ensure high precision in frequency stabilization.To validate the effectiveness of the triangular membership function,comparisons were made with fuzzy-PID controllers employing trapezoidal and Gaussian membership functions.Performance metrics,including ITAE,settling time,overshoot,and undershoot of frequency deviation,as well as tie-line power deviation,were evaluated.Robustness was established through a comprehensive sensitivity analysis with T_(G),T_(T),andT_(R) parameter variations(±50%),a non-linearity analysis incorporating Generation Rate Constraint(GRC)and Governor Deadband(GDB),a random Step Load Perturbation(SLP)over 0–100 s,and also Stability analysis of the proposed scheme is conducted using multiple approaches,including frequency-domain analysis,Lyapunov stability theory,and eigenvalue analysis.Additionally,the system incorporating thermal,hydro,and gas turbines,along with advanced components like CES and HVDC links,was analysed.Comparisons were conducted against controllers optimized using Modified Grasshopper Optimization Algorithm(MGOA),Honey Badger Algorithm(HBA),Particle Swarm Optimization(PSO),Artificial Bee Colony(ABC),and Spider Monkey Optimization(SMO)algorithms.Results demonstrate that the GWO-based fuzzy-PID controller outperforms the alternatives,exhibiting superior performance across all evaluated metrics.This highlights the potential of the proposed approach as a robust solution for load frequency control in complex and dynamic power systems.展开更多
To mitigate the challenges in managing the damage level of reinforced concrete(RC)pier columns subjected to cyclic reverse loading,this study conducted a series of cyclic reverse tests on RC pier columns.By analyzing ...To mitigate the challenges in managing the damage level of reinforced concrete(RC)pier columns subjected to cyclic reverse loading,this study conducted a series of cyclic reverse tests on RC pier columns.By analyzing the outcomes of destructive testing on various specimens and fine-tuning the results with the aid of the IMK(Ibarra Medina Krawinkler)recovery model,the energy dissipation capacity coefficient of the pier columns were able to be determined.Furthermore,utilizing the calibrated damage model parameters,the damage index for each specimen were calculated.Based on the obtained damage levels,three distinct pre-damage conditions were designed for the pier columns:minor damage,moderate damage,and severe damage.The study then predicted the variations in hysteresis curves and damage indices under cyclic loading conditions.The experimental findings reveal that the displacement at the top of the pier columns can serve as a reliable indicator for controlling the damage level of pier columns post-loading.Moreover,the calibrated damage index model exhibits proficiency in accurately predicting the damage level of RC pier columns under cyclic loading.展开更多
In contemporary power systems,delving into the flexible regulation potential of demand-side resources is of paramount significance for the efficient operation of power grids.This research puts forward an innovative mu...In contemporary power systems,delving into the flexible regulation potential of demand-side resources is of paramount significance for the efficient operation of power grids.This research puts forward an innovative multivariate flexible load aggregation control approach that takes dynamic demand response into full consideration.In the initial stage,using generalized time-domain aggregation modelling for a wide array of heterogeneous flexible loads,including temperature-controlled loads,electric vehicles,and energy storage devices,a novel calculation method for their maximum adjustable capacities is devised.Distinct from conventional methods,this newly developed approach enables more precise and adaptable quantification of the load-adjusting capabilities,thereby enhancing the accuracy and flexibility of demand-side resource management.Subsequently,an SSA-BiLSTM flexible load classification prediction model is established.This model represents an innovative application in the field,effectively combining the advantages of the Sparrow Search Algorithm(SSA)and the Bidirectional Long-Short-Term Memory(BiLSTM)neural network.Furthermore,a parallel Markov chain is introduced to evaluate the switching state transfer probability of flexible loads accurately.This integration allows for a more refined determination of the maximum response capacity range of the flexible load aggregator,significantly improving the precision of capacity assessment compared to existing methods.Finally,in consonance with the intra-day scheduling plan,a newly developed diffuse filling algorithm is implemented to control the activation times of flexible loads precisely,thus achieving real-time dynamic demand response.Through in-depth case analysis and comprehensive comparative studies,the effectiveness of the proposed method is convincingly validated.With its innovative techniques and enhanced performance,it is demonstrated that this method has the potential to substantially enhance the utilization efficiency of demand-side resources in power systems,providing a novel and effective solution for optimizing power grid operation and demand-side management.展开更多
Aiming at the challenge of complex load balancing coordination for a three-phase four-leg(3P4L)based multi-ended low voltage flexible DC distribution system(M-LVDC)considering unbalanced power compensation,this paper ...Aiming at the challenge of complex load balancing coordination for a three-phase four-leg(3P4L)based multi-ended low voltage flexible DC distribution system(M-LVDC)considering unbalanced power compensation,this paper proposes a phase-split power decoupling unbalanced compensation strategy based load balancing strategy for 3P4L based M-LVDC.Firstly,the topology and operation principle of the 3P4L-based M-LVDC system is introduced,and quasi-proportional resonant(QPR)based phase-split power current control for the 3P4L converter is proposed.Secondly,a load-balancing control strategy considering unbalanced compensation for 3P4L-based MLVDC is presented,in which the control diagrams for each 3P4L-based converter are detailed.The core idea of the proposed strategy is to comprehensively consider the imbalance compensation and load rate balancing between the two areas to calculate the split-phase power and current reference values of each 3P4L converter and achieve the static error-free tracking of the reference values through the QPR current inner-loop control.These reference values are then tracked with zero steady-state error using QPR current inner-loop control.Finally,the effectiveness of the proposed control strategy is verified through a 3P4L M-LVDC case study conducted on the PSCAD/EMTDC software.Theresults indicate that the proposed method not only can reduce the three-phase imbalance degrees from>20% to<0.5%,but also achieve excellent balanced load rates,with the load-rate difference smaller than 1.5%.展开更多
This study presents the use of an innovative population-based algorithm called the Sine Cosine Algorithm and its metaheuristic form,Quasi Oppositional Sine Cosine Algorithm,to automatic generation control of a multipl...This study presents the use of an innovative population-based algorithm called the Sine Cosine Algorithm and its metaheuristic form,Quasi Oppositional Sine Cosine Algorithm,to automatic generation control of a multiple-source-based interconnected power system that consists of thermal,gas,and hydro power plants.The Proportional-Integral-Derivative controller,which is utilized for automated generation control in an interconnected hybrid power systemwith aDClink connecting two regions,has been tuned using the proposed optimization technique.An Electric Vehicle is taken into consideration only as an electrical load.The Quasi Oppositional Sine Cosinemethod’s performance and efficacy have been compared to the Sine Cosine Algorithm and optimal output feedback controller tuning performance.Applying the QOSCA optimization technique,which has only been shown in this study in the context of an LFC research thus far,makes this paper unique.The main objective has been used to assess and compare the dynamic performances of the recommended controller along with QOSCA optimisation technic.The resilience of the controller is examined using two different system parameters:B(frequency bias parameter)and R(governor speed regulation).The sensitivity analysis results demonstrate the high reliability of the QOSCA algorithm-based controller.Once optimal controller gains are established for nominal conditions,step load perturbations up to±10%&±25%in the nominal values of the systemparameters and operational load condition do not require adjustment of the controller.Ultimately,a scenario is examined whereby EVs are used for area 1,and a single PID controller is used rather than three.展开更多
Aiming to solve the steering instability and hysteresis of agricultural robots in the process of movement,a fusion PID control method of particle swarm optimization(PSO)and genetic algorithm(GA)was proposed.The fusion...Aiming to solve the steering instability and hysteresis of agricultural robots in the process of movement,a fusion PID control method of particle swarm optimization(PSO)and genetic algorithm(GA)was proposed.The fusion algorithm took advantage of the fast optimization ability of PSO to optimize the population screening link of GA.The Simulink simulation results showed that the convergence of the fitness function of the fusion algorithm was accelerated,the system response adjustment time was reduced,and the overshoot was almost zero.Then the algorithm was applied to the steering test of agricultural robot in various scenes.After modeling the steering system of agricultural robot,the steering test results in the unloaded suspended state showed that the PID control based on fusion algorithm reduced the rise time,response adjustment time and overshoot of the system,and improved the response speed and stability of the system,compared with the artificial trial and error PID control and the PID control based on GA.The actual road steering test results showed that the PID control response rise time based on the fusion algorithm was the shortest,about 4.43 s.When the target pulse number was set to 100,the actual mean value in the steady-state regulation stage was about 102.9,which was the closest to the target value among the three control methods,and the overshoot was reduced at the same time.The steering test results under various scene states showed that the PID control based on the proposed fusion algorithm had good anti-interference ability,it can adapt to the changes of environment and load and improve the performance of the control system.It was effective in the steering control of agricultural robot.This method can provide a reference for the precise steering control of other robots.展开更多
In this paper,we consider the maximal positive definite solution of the nonlinear matrix equation.By using the idea of Algorithm 2.1 in ZHANG(2013),a new inversion-free method with a stepsize parameter is proposed to ...In this paper,we consider the maximal positive definite solution of the nonlinear matrix equation.By using the idea of Algorithm 2.1 in ZHANG(2013),a new inversion-free method with a stepsize parameter is proposed to obtain the maximal positive definite solution of nonlinear matrix equation X+A^(*)X|^(-α)A=Q with the case 0<α≤1.Based on this method,a new iterative algorithm is developed,and its convergence proof is given.Finally,two numerical examples are provided to show the effectiveness of the proposed method.展开更多
To achieve the manufacturing of Thin-Wall and High-Rib Components(TWHRC)with high precision,a novel heavy load Multi-DOF Envelope Forming Press(MEFP)with Parallel Kinematic Mechanism(PKM),driven by six Permanent Magne...To achieve the manufacturing of Thin-Wall and High-Rib Components(TWHRC)with high precision,a novel heavy load Multi-DOF Envelope Forming Press(MEFP)with Parallel Kinematic Mechanism(PKM),driven by six Permanent Magnet Synchronous Motors(PMSMs),is developed.However,on account of the heavy forming load,the PMSM parameters are in great variation.Meanwhile,the PMSM is always in a transient state caused by fast time-varying forming load,resulting in low identification precision of varied PMSM parameters and control precision of PMSM under traditional parameter identification methods.To solve this problem,a novel Sliding Mode Control Method with Enhanced PMSM Parameter Identification(SMCMEPPI)for heavy load MEFP is proposed.Firstly,the kinematic model of MEFP is established.Secondly,the variation law of PMSM parameters under heavy load is revealed.Thirdly,an enhanced PMSM parameter identification method is proposed,in which the q axis current of PMSM is used to represent the changing rate of forming load and the adjustment factor is first proposed to remove improper input of PMSM parameter identification online.Fourthly,the Electromechanical Coupling Dynamic Model(ECDM)of MEFP,which includes identified PMSM parameters,is developed.Finally,based on the developed ECDM,a novel SMCMEPPI is proposed to realize the high-precision control of heavy load MEFP.The experimental results indicate that the proposed SMCMEPPI can significantly improve the control precision of heavy load MEFP.展开更多
Molten salt reactors,being the only reactor type among Generation Ⅳ advanced nuclear reactors that utilize liquid fuels,offer inherent safety,high-temperature,and low-pressure operation,as well as the capability for ...Molten salt reactors,being the only reactor type among Generation Ⅳ advanced nuclear reactors that utilize liquid fuels,offer inherent safety,high-temperature,and low-pressure operation,as well as the capability for online fuel reprocessing.However,the fuel-salt flow results in the decay of delayed neutron precursors(DNPs)outside the core,causing fluctuations in the effective delayed neutron fraction and consequently impacting the reactor reactivity.Particularly in accident scenarios—such as a combined pump shutdown and the inability to rapidly scram the reactor—the sole reliance on negative temperature feedback may cause a significant increase in core temperature,posing a threat to reactor safety.To address these problems,this paper introduces an innovative design for a passive fluid-driven suspended control rod(SCR)to dynamically compensate for reactivity fluctuations caused by DNPs flowing with the fuel.The control rod operates passively by leveraging the combined effects of gravity,buoyancy,and fluid dynamic forces,thereby eliminating the need for an external drive mechanism and enabling direct integration within the active region of the core.Using a 150 MWt thorium-based molten salt reactor as the reference design,we develop a mathematical model to systematically analyze the effects of key parameters—including the geometric dimensions and density of the SCR—on its performance.We examine its motion characteristics under different core flow conditions and assess its feasibility for the dynamic compensation of reactivity changes caused by fuel flow.The results of this study demonstrate that the SCR can effectively counteract reactivity fluctuations induced by fuel flow within molten salt reactors.A sensitivity analysis reveals that the SCR’s average density exerts a profound impact on its start-up flow threshold,channel flow rate,resistance to fuel density fluctuations,and response characteristics.This underscores the critical need to optimize this parameter.Moreover,by judiciously selecting the SCR’s length,number of deployed units,and the placement we can achieve the necessary reactivity control while maintaining a favorable balance between neutron economy and heat transfer performance.Ultimately,this paper provides an innovative solution for the passive reactivity control in molten salt reactors,offering significant potential for practical engineering applications.展开更多
Studies of wave-current interactions are vital for the safe design of structures.Regular waves in the presence of uniform,linear shear,and quadratic shear currents are explored by the High-Level Green-Naghdi model in ...Studies of wave-current interactions are vital for the safe design of structures.Regular waves in the presence of uniform,linear shear,and quadratic shear currents are explored by the High-Level Green-Naghdi model in this paper.The five-point central difference method is used for spatial discretization,and the fourth-order Adams predictor-corrector scheme is employed for marching in time.The domain-decomposition method is applied for the wave-current generation and absorption.The effects of currents on the wave profile and velocity field are examined under two conditions:the same velocity of currents at the still-water level and the constant flow volume of currents.Wave profiles and velocity fields demonstrate substantial differences in three types of currents owing to the diverse vertical distribution of current velocity and vorticity.Then,loads on small-scale vertical cylinders subjected to regular waves and three types of background currents with the same flow volume are investigated.The maximum load intensity and load fluctuation amplitude in uniform,linear shear,and quadratic shear currents increase sequentially.The stretched superposition method overestimates the maximum load intensity and load fluctuation amplitude in opposing currents and underestimates these values in following currents.The stretched superposition method obtains a poor approximation for strong nonlinear waves,particularly in the case of the opposing quadratic shear current.展开更多
Modern power systems increasingly depend on interconnected microgrids to enhance reliability and renewable energy utilization.However,the high penetration of intermittent renewable sources often causes frequency devia...Modern power systems increasingly depend on interconnected microgrids to enhance reliability and renewable energy utilization.However,the high penetration of intermittent renewable sources often causes frequency deviations,voltage fluctuations,and poor reactive power coordination,posing serious challenges to grid stability.Conventional Interconnection FlowControllers(IFCs)primarily regulate active power flowand fail to effectively handle dynamic frequency variations or reactive power sharing in multi-microgrid networks.To overcome these limitations,this study proposes an enhanced Interconnection Flow Controller(e-IFC)that integrates frequency response balancing and an Interconnection Reactive Power Flow Controller(IRFC)within a unified adaptive control structure.The proposed e-IFC is implemented and analyzed in DIgSILENT PowerFactory to evaluate its performance under various grid disturbances,including frequency drops,load changes,and reactive power fluctuations.Simulation results reveal that the e-IFC achieves 27.4% higher active power sharing accuracy,19.6% lower reactive power deviation,and 18.2% improved frequency stability compared to the conventional IFC.The adaptive controller ensures seamless transitions between grid-connected and islanded modes and maintains stable operation even under communication delays and data noise.Overall,the proposed e-IFCsignificantly enhances active-reactive power coordination and dynamic stability in renewable-integrated multi-microgrid systems.Future research will focus on coupling the e-IFC with tertiary-level optimization frameworks and conducting hardware-in-the-loop validation to enable its application in large-scale smart microgrid environments.展开更多
This study establishes and validates a method for the precise quantification of aquatic microbial loads using microbial diversity absolute quantitative sequencing.By adding synthetic spike-in DNA to water samples from...This study establishes and validates a method for the precise quantification of aquatic microbial loads using microbial diversity absolute quantitative sequencing.By adding synthetic spike-in DNA to water samples from the Dahei River prior to DNA extraction and 16S rRNA gene sequencing,it generates standard curves to convert sequencing data into absolute microbial copy numbers.The method,which is proved highly accurate(R^(2)>0.99),reveals a clear contrast between the river sites:the upstream community has not only a significantly higher total microbial load but also a completely different makeup of species compared to the downstream site.This approach effectively overcomes the limitations of relative abundance analysis,providing a powerful tool for environmental monitoring,and proposes key steps for future standardization to ensure data comparability and integration.展开更多
Conventional multilevel inverters often suffer from high harmonic distortion and increased design complexity due to the need for numerous power semiconductor components,particularly at elevated voltage levels.Addressi...Conventional multilevel inverters often suffer from high harmonic distortion and increased design complexity due to the need for numerous power semiconductor components,particularly at elevated voltage levels.Addressing these shortcomings,thiswork presents a robust 15-level PackedUCell(PUC)inverter topology designed for renewable energy and grid-connected applications.The proposed systemintegrates a sensor less proportional-resonant(PR)controller with an advanced carrier-based pulse width modulation scheme.This approach efficiently balances capacitor voltage,minimizes steady-state error,and strongly suppresses both zero and third-order harmonics resulting in reduced total harmonic distortion and enhanced voltage regulation.Additionally,a novel switching algorithm simplifies the design and implementation,further lowering voltage stress across switches.Extensive simulation results validate the performance under various resistive and resistive-inductive load conditions,demonstrating compliance with IEEE-519 THD standards and robust operation under dynamic changes.The proposed sensorless PR-controlled 15-PUC inverter thus offers a compelling,cost-effective solution for efficient power conversion in next-generation renewable energy systems.展开更多
To address the issue of instability or even imbalance in the orientation and attitude control of quadrotor unmanned aerial vehicles(QUAVs)under random disturbances,this paper proposes a distributed antidisturbance dat...To address the issue of instability or even imbalance in the orientation and attitude control of quadrotor unmanned aerial vehicles(QUAVs)under random disturbances,this paper proposes a distributed antidisturbance data-driven event-triggered fusion control method,which achieves efficient fault diagnosis while suppressing random disturbances and mitigating communication conflicts within the QUAV swarm.First,the impact of random disturbances on the UAV swarm is analyzed,and a model for orientation and attitude control of QUAVs under stochastic perturbations is established,with the disturbance gain threshold determined.Second,a fault diagnosis system based on a high-gain observer is designed,constructing a fault gain criterion by integrating orientation and attitude information from QUAVs.Subsequently,a model-free dynamic linearization-based data modeling(MFDLDM)framework is developed using model-free adaptive control,which efficiently fits the nonlinear control model of the QUAV swarm while reducing temporal constraints on control data.On this basis,this paper constructs a distributed data-driven event-triggered controller based on the staggered communication mechanism,which consists of an equivalent QUAV controller and an event-triggered controller,and is able to reduce the communication conflicts while suppressing the influence of random interference.Finally,by incorporating random disturbances into the controller,comparative experiments and physical validations are conducted on the QUAV platforms,fully demonstrating the strong adaptability and robustness of the proposed distributed event-triggered fault-tolerant control system.展开更多
Grid-Forming(GFM)converters are prone to fault-induced overcurrent and power angle instability during grid fault-induced voltage sags.To address this,this paper develops a multi-loop coordinated fault ridethrough(FRT)...Grid-Forming(GFM)converters are prone to fault-induced overcurrent and power angle instability during grid fault-induced voltage sags.To address this,this paper develops a multi-loop coordinated fault ridethrough(FRT)control strategy based on a power outer loop and voltage-current inner loops,aiming to enhance the stability and current-limiting capability of GFM converters during grid fault conditions.During voltage sags,the GFM converter’s voltage source behavior is maintained by dynamically adjusting the reactive power reference to provide voltage support,thereby effectively suppressing the steady-state component of the fault current.To address the active power imbalance induced by voltage sags,a dynamic active power reference correction method based on apparent power is designed to mitigate power angle oscillations and limit transient current.Moreover,an adaptive virtual impedance loop is implemented to enhance dynamic transient current-limiting performance during the fault initiation phase.This approach improves the responsiveness of the inner loop and ensures safe system operation under various fault severities.Under asymmetric fault conditions,a negative-sequence reactive current compensation strategy is incorporated to further suppress negative-sequence voltage and improve voltage symmetry.The proposed control scheme enables coordinated operation of multiple control objectives,including voltage support,current suppression,and power angle stability,across different fault scenarios.Finally,MATLAB/Simulink simulation results validate the effectiveness of the proposed strategy,showcasing its superior performance in current limiting and power angle stability,thereby significantly enhancing the system’s fault ride-through capability.展开更多
Understanding water chemistry in karst regions is crucial for improving global water resource management and deepening our knowledge of the biogeochemical cycles shaping these sensitive environments.Despite advance-me...Understanding water chemistry in karst regions is crucial for improving global water resource management and deepening our knowledge of the biogeochemical cycles shaping these sensitive environments.Despite advance-ments in karst hydrology,significant gaps remain in long-term trends,underlying processes,and quantitative effects of environmental changes.This is especially true in areas like the Wujiang River(WJ)in China,where human activities such as reservoir construction and land use/cover changes have accelerated hydrochemical changes.We combined recent and historical monitoring data to provide a detailed analysis of the spatial and temporal characteristics,evolution,and controlling factors of major ions in WJ.These findings are important for local water management and contribute to global efforts to manage similar karst systems facing human-induced pressures.Our research shows clear seasonal differences in solute concentrations,with higher levels during the dry season.WJ’s water is rich in calcium,with Ca-HCO_(3) ion pairs being the most common.Reservoir monitor-ing stations show much higher levels of NO_(3)^(−)and SO_(4)^(2−)compared to river-type stations,likely due to longer hydraulic retention time and increased acid deposition.The study confirms the significant role of pH and water temperature in rock weathering processes.Land use/cover changes were identified as the primary drivers of solute variations(46.37%),followed by lithology(13.92%)and temperature(8.35%).Over the past two decades,in-tense carbonate weathering has been observed,especially during wet seasons.Among karstic provinces,Guizhou Province stands out with the highest ion concentrations,indicative of its extensive karst coverage and heightened weathering processes.展开更多
In wind power transmission via modular multilevel converter based high voltage direct current(MMCHVDC)systems,under traditional control strategies,MMC-HVDCcannot provide inertia support to the receiving-end grid(REG)d...In wind power transmission via modular multilevel converter based high voltage direct current(MMCHVDC)systems,under traditional control strategies,MMC-HVDCcannot provide inertia support to the receiving-end grid(REG)during disturbances.Moreover,due to the frequency decoupling between the two ends of the MMCHVDC,the sending-end wind farm(SEWF)cannot obtain the frequency variation information of the REG to provide inertia response.Therefore,this paper proposes a novel coordinated source-network-storage inertia control strategy based on wind power transmission via MMC-HVDC system.First,the grid-side MMC station(GS-MMC)maps the frequency variations of the REG to direct current(DC)voltage variations through the frequency mapping control,and uses submodule capacitor energy to provide inertial power.Then,the wind farm-side MMC station(WF-MMC)restores the DC voltage variations to frequency variations through the frequency restoration control and power loss compensation,providing real-time frequency information for the wind farm.Finally,based on real-time frequency information,thewind farmutilizes the rotor kinetic energy and energy storage to provide fast and lasting power support through the wind-storage coordinated inertia control strategy.Meanwhile,when the wind turbines withdraw from the inertia response phase,the energy storage can increase the power output to compensate for the power deficit,preventing secondary frequency drops.Furthermore,this paper uses small-signal analysis to determine the appropriate values for the key parameters of the proposed control strategy.A simulation model of the wind power transmission via MMCHVDC system is built in MATLAB/Simulink environment to validate and evaluate the proposed method.The results show that the proposed coordinated control strategy can effectively improve the system inertia level and avoid the secondary frequency drop under the load sudden increase condition.展开更多
Quantum control allows a wide range of quantum operations employed in molecular physics,nuclear magnetic resonance and quantum information processing.Thanks to the existing microelectronics industry,semiconducting qub...Quantum control allows a wide range of quantum operations employed in molecular physics,nuclear magnetic resonance and quantum information processing.Thanks to the existing microelectronics industry,semiconducting qubits,where quantum information is encoded in spin or charge degree freedom of electrons or nuclei in semiconductor quantum dots,constitute a highly competitive candidate for scalable solid-state quantum technologies.In quantum information processing,advanced control techniques are needed to realize quantum manipulations with both high precision and noise resilience.In this review,we first introduce the basics of various widely-used control methods,including resonant excitation,adabatic passage,shortcuts to adiabaticity,composite pulses,and quantum optimal control.Then we review the practical aspects in applying these methods to realize accurate and robust quantum gates for single semiconductor qubits,such as Loss–DiVincenzo spin qubit,spinglet-triplet qubit,exchange-only qubit and charge qubit.展开更多
基金Supported by the Russian Science Foundation(Agreement 23-41-10001,https://rscf.ru/project/23-41-10001/).
文摘Background Interconnection of different power systems has a major effect on system stability.This study aims to design an optimal load frequency control(LFC)system based on a proportional-integral(PI)controller for a two-area power system.Methods Two areas were connected through an AC tie line in parallel with a DC link to stabilize the frequency of oscillations in both areas.The PI parameters were tuned using the cuckoo search algorithm(CSA)to minimize the integral absolute error(IAE).A state matrix was provided,and the stability of the system was verified by calculating the eigenvalues.The frequency response was investigated for load variation,changes in the generator rate constraint,the turbine time constant,and the governor time constant.Results The CSA was compared with particle swarm optimization algorithm(PSO)under identical conditions.The system was modeled based on a state-space mathematical representation and simulated using MATLAB.The results demonstrated the effectiveness of the proposed controller based on both algorithms and,it is clear that CSA is superior to PSO.Conclusion The CSA algorithm smoothens the system response,reduces ripples,decreases overshooting and settling time,and improves the overall system performance under different disturbances.
基金supported by the Key Scientific and Technological Projects(2024KJGG27)of Tianfu Yongxing Laboratorythe Experimental Platform Open Innovation Funding(209042025003)of Sichuan Energy Internet Research Institute,Tsinghua University.
文摘As the development of new power systems progresses,the inherent inertia of power systems continues to diminish.Centralized frequency regulation,which relies on rapid communication and real-time control,can enable inverter-based thermostatically controlled load(ITCL)clusters to provide virtual inertia support to the power grid.However,ITCL clusters exhibit significant discrete response characteristics,which precludes the direct integration of load-side inertia support into the synchronous unit side.To address this issue,this paper elaborates on the existing technical framework and analyzes the underlying causes of the problem.It proposes a timestamp allocation mechanism for ITCL cluster control instructions,ensuring that many ITCL terminals can be triggered at staggered times,thereby allowing the load cluster power to adhere to the inertia analog control law at any moment.Building on this foundation,the paper further examines the impact of the inertia response delay of ITCL clusters,which is based on centralized frequency regulation,on the stability of the power system.A design scheme for inertia analog control parameters is proposed,taking into account dual constraints,frequency stability and load cluster regulation capacity.Finally,the feasibility and applicability of the proposed mechanism and parameter design scheme are investigated through simulations conducted via MATLAB/Simulink.
文摘This study develops a GWO-optimized cascaded fuzzy-PID controller with triangular membership functions for load frequency control in interconnected power systems.The controller’s effectiveness is demonstrated on thermal–thermal and hybrid thermal–hydro–gas power systems.The controller parameters were tuned using the Integral Time Absolute Error(ITAE)objective function,which was also evaluated alongside other objective functions(IAE,ISE,and ITSE)to ensure high precision in frequency stabilization.To validate the effectiveness of the triangular membership function,comparisons were made with fuzzy-PID controllers employing trapezoidal and Gaussian membership functions.Performance metrics,including ITAE,settling time,overshoot,and undershoot of frequency deviation,as well as tie-line power deviation,were evaluated.Robustness was established through a comprehensive sensitivity analysis with T_(G),T_(T),andT_(R) parameter variations(±50%),a non-linearity analysis incorporating Generation Rate Constraint(GRC)and Governor Deadband(GDB),a random Step Load Perturbation(SLP)over 0–100 s,and also Stability analysis of the proposed scheme is conducted using multiple approaches,including frequency-domain analysis,Lyapunov stability theory,and eigenvalue analysis.Additionally,the system incorporating thermal,hydro,and gas turbines,along with advanced components like CES and HVDC links,was analysed.Comparisons were conducted against controllers optimized using Modified Grasshopper Optimization Algorithm(MGOA),Honey Badger Algorithm(HBA),Particle Swarm Optimization(PSO),Artificial Bee Colony(ABC),and Spider Monkey Optimization(SMO)algorithms.Results demonstrate that the GWO-based fuzzy-PID controller outperforms the alternatives,exhibiting superior performance across all evaluated metrics.This highlights the potential of the proposed approach as a robust solution for load frequency control in complex and dynamic power systems.
基金supported by National Natural Science Foundation of China(Project No.51878156)EPC Innovation Consulting Project for Longkou Nanshan LNG Phase I Receiving Terminal(Z2000LGENT0399).
文摘To mitigate the challenges in managing the damage level of reinforced concrete(RC)pier columns subjected to cyclic reverse loading,this study conducted a series of cyclic reverse tests on RC pier columns.By analyzing the outcomes of destructive testing on various specimens and fine-tuning the results with the aid of the IMK(Ibarra Medina Krawinkler)recovery model,the energy dissipation capacity coefficient of the pier columns were able to be determined.Furthermore,utilizing the calibrated damage model parameters,the damage index for each specimen were calculated.Based on the obtained damage levels,three distinct pre-damage conditions were designed for the pier columns:minor damage,moderate damage,and severe damage.The study then predicted the variations in hysteresis curves and damage indices under cyclic loading conditions.The experimental findings reveal that the displacement at the top of the pier columns can serve as a reliable indicator for controlling the damage level of pier columns post-loading.Moreover,the calibrated damage index model exhibits proficiency in accurately predicting the damage level of RC pier columns under cyclic loading.
基金the Science and Technology Project of State Grid Shanxi Electric Power Co.,Ltd.,with the project number 52051L240001.
文摘In contemporary power systems,delving into the flexible regulation potential of demand-side resources is of paramount significance for the efficient operation of power grids.This research puts forward an innovative multivariate flexible load aggregation control approach that takes dynamic demand response into full consideration.In the initial stage,using generalized time-domain aggregation modelling for a wide array of heterogeneous flexible loads,including temperature-controlled loads,electric vehicles,and energy storage devices,a novel calculation method for their maximum adjustable capacities is devised.Distinct from conventional methods,this newly developed approach enables more precise and adaptable quantification of the load-adjusting capabilities,thereby enhancing the accuracy and flexibility of demand-side resource management.Subsequently,an SSA-BiLSTM flexible load classification prediction model is established.This model represents an innovative application in the field,effectively combining the advantages of the Sparrow Search Algorithm(SSA)and the Bidirectional Long-Short-Term Memory(BiLSTM)neural network.Furthermore,a parallel Markov chain is introduced to evaluate the switching state transfer probability of flexible loads accurately.This integration allows for a more refined determination of the maximum response capacity range of the flexible load aggregator,significantly improving the precision of capacity assessment compared to existing methods.Finally,in consonance with the intra-day scheduling plan,a newly developed diffuse filling algorithm is implemented to control the activation times of flexible loads precisely,thus achieving real-time dynamic demand response.Through in-depth case analysis and comprehensive comparative studies,the effectiveness of the proposed method is convincingly validated.With its innovative techniques and enhanced performance,it is demonstrated that this method has the potential to substantially enhance the utilization efficiency of demand-side resources in power systems,providing a novel and effective solution for optimizing power grid operation and demand-side management.
基金supported by the key technology project of China Southern Power Grid Corporation(GZKJXM20220041)partly by theNational Key Research and Development Plan(2022YFE0205300).
文摘Aiming at the challenge of complex load balancing coordination for a three-phase four-leg(3P4L)based multi-ended low voltage flexible DC distribution system(M-LVDC)considering unbalanced power compensation,this paper proposes a phase-split power decoupling unbalanced compensation strategy based load balancing strategy for 3P4L based M-LVDC.Firstly,the topology and operation principle of the 3P4L-based M-LVDC system is introduced,and quasi-proportional resonant(QPR)based phase-split power current control for the 3P4L converter is proposed.Secondly,a load-balancing control strategy considering unbalanced compensation for 3P4L-based MLVDC is presented,in which the control diagrams for each 3P4L-based converter are detailed.The core idea of the proposed strategy is to comprehensively consider the imbalance compensation and load rate balancing between the two areas to calculate the split-phase power and current reference values of each 3P4L converter and achieve the static error-free tracking of the reference values through the QPR current inner-loop control.These reference values are then tracked with zero steady-state error using QPR current inner-loop control.Finally,the effectiveness of the proposed control strategy is verified through a 3P4L M-LVDC case study conducted on the PSCAD/EMTDC software.Theresults indicate that the proposed method not only can reduce the three-phase imbalance degrees from>20% to<0.5%,but also achieve excellent balanced load rates,with the load-rate difference smaller than 1.5%.
文摘This study presents the use of an innovative population-based algorithm called the Sine Cosine Algorithm and its metaheuristic form,Quasi Oppositional Sine Cosine Algorithm,to automatic generation control of a multiple-source-based interconnected power system that consists of thermal,gas,and hydro power plants.The Proportional-Integral-Derivative controller,which is utilized for automated generation control in an interconnected hybrid power systemwith aDClink connecting two regions,has been tuned using the proposed optimization technique.An Electric Vehicle is taken into consideration only as an electrical load.The Quasi Oppositional Sine Cosinemethod’s performance and efficacy have been compared to the Sine Cosine Algorithm and optimal output feedback controller tuning performance.Applying the QOSCA optimization technique,which has only been shown in this study in the context of an LFC research thus far,makes this paper unique.The main objective has been used to assess and compare the dynamic performances of the recommended controller along with QOSCA optimisation technic.The resilience of the controller is examined using two different system parameters:B(frequency bias parameter)and R(governor speed regulation).The sensitivity analysis results demonstrate the high reliability of the QOSCA algorithm-based controller.Once optimal controller gains are established for nominal conditions,step load perturbations up to±10%&±25%in the nominal values of the systemparameters and operational load condition do not require adjustment of the controller.Ultimately,a scenario is examined whereby EVs are used for area 1,and a single PID controller is used rather than three.
文摘Aiming to solve the steering instability and hysteresis of agricultural robots in the process of movement,a fusion PID control method of particle swarm optimization(PSO)and genetic algorithm(GA)was proposed.The fusion algorithm took advantage of the fast optimization ability of PSO to optimize the population screening link of GA.The Simulink simulation results showed that the convergence of the fitness function of the fusion algorithm was accelerated,the system response adjustment time was reduced,and the overshoot was almost zero.Then the algorithm was applied to the steering test of agricultural robot in various scenes.After modeling the steering system of agricultural robot,the steering test results in the unloaded suspended state showed that the PID control based on fusion algorithm reduced the rise time,response adjustment time and overshoot of the system,and improved the response speed and stability of the system,compared with the artificial trial and error PID control and the PID control based on GA.The actual road steering test results showed that the PID control response rise time based on the fusion algorithm was the shortest,about 4.43 s.When the target pulse number was set to 100,the actual mean value in the steady-state regulation stage was about 102.9,which was the closest to the target value among the three control methods,and the overshoot was reduced at the same time.The steering test results under various scene states showed that the PID control based on the proposed fusion algorithm had good anti-interference ability,it can adapt to the changes of environment and load and improve the performance of the control system.It was effective in the steering control of agricultural robot.This method can provide a reference for the precise steering control of other robots.
基金Supported in part by Natural Science Foundation of Guangxi(2023GXNSFAA026246)in part by the Central Government's Guide to Local Science and Technology Development Fund(GuikeZY23055044)in part by the National Natural Science Foundation of China(62363003)。
文摘In this paper,we consider the maximal positive definite solution of the nonlinear matrix equation.By using the idea of Algorithm 2.1 in ZHANG(2013),a new inversion-free method with a stepsize parameter is proposed to obtain the maximal positive definite solution of nonlinear matrix equation X+A^(*)X|^(-α)A=Q with the case 0<α≤1.Based on this method,a new iterative algorithm is developed,and its convergence proof is given.Finally,two numerical examples are provided to show the effectiveness of the proposed method.
基金the National Science and Technology Major Project of China(No.2019-Ⅶ-0017-0158)the National Natural Science Foundation of China(Nos.U2037204,U21A20131)the Innovative Research Team Development Program of Ministry of Education of China(No.IRT17R83)for the support given to this research。
文摘To achieve the manufacturing of Thin-Wall and High-Rib Components(TWHRC)with high precision,a novel heavy load Multi-DOF Envelope Forming Press(MEFP)with Parallel Kinematic Mechanism(PKM),driven by six Permanent Magnet Synchronous Motors(PMSMs),is developed.However,on account of the heavy forming load,the PMSM parameters are in great variation.Meanwhile,the PMSM is always in a transient state caused by fast time-varying forming load,resulting in low identification precision of varied PMSM parameters and control precision of PMSM under traditional parameter identification methods.To solve this problem,a novel Sliding Mode Control Method with Enhanced PMSM Parameter Identification(SMCMEPPI)for heavy load MEFP is proposed.Firstly,the kinematic model of MEFP is established.Secondly,the variation law of PMSM parameters under heavy load is revealed.Thirdly,an enhanced PMSM parameter identification method is proposed,in which the q axis current of PMSM is used to represent the changing rate of forming load and the adjustment factor is first proposed to remove improper input of PMSM parameter identification online.Fourthly,the Electromechanical Coupling Dynamic Model(ECDM)of MEFP,which includes identified PMSM parameters,is developed.Finally,based on the developed ECDM,a novel SMCMEPPI is proposed to realize the high-precision control of heavy load MEFP.The experimental results indicate that the proposed SMCMEPPI can significantly improve the control precision of heavy load MEFP.
基金supported by Youth Innovation Promotion Association of Chinese Academy of Sciences(No.2020261)Strategic Priority Research Program of Chinese Academy of Sciences(No.XDA02010000)the Young Potential Program of Shanghai Institute of Applied Physics,Chinese Academy of Sciences(No.SINAP-YXJH-202412).
文摘Molten salt reactors,being the only reactor type among Generation Ⅳ advanced nuclear reactors that utilize liquid fuels,offer inherent safety,high-temperature,and low-pressure operation,as well as the capability for online fuel reprocessing.However,the fuel-salt flow results in the decay of delayed neutron precursors(DNPs)outside the core,causing fluctuations in the effective delayed neutron fraction and consequently impacting the reactor reactivity.Particularly in accident scenarios—such as a combined pump shutdown and the inability to rapidly scram the reactor—the sole reliance on negative temperature feedback may cause a significant increase in core temperature,posing a threat to reactor safety.To address these problems,this paper introduces an innovative design for a passive fluid-driven suspended control rod(SCR)to dynamically compensate for reactivity fluctuations caused by DNPs flowing with the fuel.The control rod operates passively by leveraging the combined effects of gravity,buoyancy,and fluid dynamic forces,thereby eliminating the need for an external drive mechanism and enabling direct integration within the active region of the core.Using a 150 MWt thorium-based molten salt reactor as the reference design,we develop a mathematical model to systematically analyze the effects of key parameters—including the geometric dimensions and density of the SCR—on its performance.We examine its motion characteristics under different core flow conditions and assess its feasibility for the dynamic compensation of reactivity changes caused by fuel flow.The results of this study demonstrate that the SCR can effectively counteract reactivity fluctuations induced by fuel flow within molten salt reactors.A sensitivity analysis reveals that the SCR’s average density exerts a profound impact on its start-up flow threshold,channel flow rate,resistance to fuel density fluctuations,and response characteristics.This underscores the critical need to optimize this parameter.Moreover,by judiciously selecting the SCR’s length,number of deployed units,and the placement we can achieve the necessary reactivity control while maintaining a favorable balance between neutron economy and heat transfer performance.Ultimately,this paper provides an innovative solution for the passive reactivity control in molten salt reactors,offering significant potential for practical engineering applications.
基金Supported by the Development and Application Project of Ship CAE Software.
文摘Studies of wave-current interactions are vital for the safe design of structures.Regular waves in the presence of uniform,linear shear,and quadratic shear currents are explored by the High-Level Green-Naghdi model in this paper.The five-point central difference method is used for spatial discretization,and the fourth-order Adams predictor-corrector scheme is employed for marching in time.The domain-decomposition method is applied for the wave-current generation and absorption.The effects of currents on the wave profile and velocity field are examined under two conditions:the same velocity of currents at the still-water level and the constant flow volume of currents.Wave profiles and velocity fields demonstrate substantial differences in three types of currents owing to the diverse vertical distribution of current velocity and vorticity.Then,loads on small-scale vertical cylinders subjected to regular waves and three types of background currents with the same flow volume are investigated.The maximum load intensity and load fluctuation amplitude in uniform,linear shear,and quadratic shear currents increase sequentially.The stretched superposition method overestimates the maximum load intensity and load fluctuation amplitude in opposing currents and underestimates these values in following currents.The stretched superposition method obtains a poor approximation for strong nonlinear waves,particularly in the case of the opposing quadratic shear current.
基金the Deanship of Scientific Research at Northern Border University,Arar,Saudi Arabia,for funding this research work through the project number“NBU-FFR-2025-3623-11”.
文摘Modern power systems increasingly depend on interconnected microgrids to enhance reliability and renewable energy utilization.However,the high penetration of intermittent renewable sources often causes frequency deviations,voltage fluctuations,and poor reactive power coordination,posing serious challenges to grid stability.Conventional Interconnection FlowControllers(IFCs)primarily regulate active power flowand fail to effectively handle dynamic frequency variations or reactive power sharing in multi-microgrid networks.To overcome these limitations,this study proposes an enhanced Interconnection Flow Controller(e-IFC)that integrates frequency response balancing and an Interconnection Reactive Power Flow Controller(IRFC)within a unified adaptive control structure.The proposed e-IFC is implemented and analyzed in DIgSILENT PowerFactory to evaluate its performance under various grid disturbances,including frequency drops,load changes,and reactive power fluctuations.Simulation results reveal that the e-IFC achieves 27.4% higher active power sharing accuracy,19.6% lower reactive power deviation,and 18.2% improved frequency stability compared to the conventional IFC.The adaptive controller ensures seamless transitions between grid-connected and islanded modes and maintains stable operation even under communication delays and data noise.Overall,the proposed e-IFCsignificantly enhances active-reactive power coordination and dynamic stability in renewable-integrated multi-microgrid systems.Future research will focus on coupling the e-IFC with tertiary-level optimization frameworks and conducting hardware-in-the-loop validation to enable its application in large-scale smart microgrid environments.
基金supported by the National Natural Science Foundation of China(Grant No.32160172)the Key Science-Technology Project of Inner Mongolia(2023KYPT0010)+1 种基金the Natural Science Foundation of Inner Mongolia Autonomous Region of China(Grant No.2025QN03006)the 2023 Inner Mongolia Public Institution High-level Talent Introduction Scientific Research Support Project.
文摘This study establishes and validates a method for the precise quantification of aquatic microbial loads using microbial diversity absolute quantitative sequencing.By adding synthetic spike-in DNA to water samples from the Dahei River prior to DNA extraction and 16S rRNA gene sequencing,it generates standard curves to convert sequencing data into absolute microbial copy numbers.The method,which is proved highly accurate(R^(2)>0.99),reveals a clear contrast between the river sites:the upstream community has not only a significantly higher total microbial load but also a completely different makeup of species compared to the downstream site.This approach effectively overcomes the limitations of relative abundance analysis,providing a powerful tool for environmental monitoring,and proposes key steps for future standardization to ensure data comparability and integration.
文摘Conventional multilevel inverters often suffer from high harmonic distortion and increased design complexity due to the need for numerous power semiconductor components,particularly at elevated voltage levels.Addressing these shortcomings,thiswork presents a robust 15-level PackedUCell(PUC)inverter topology designed for renewable energy and grid-connected applications.The proposed systemintegrates a sensor less proportional-resonant(PR)controller with an advanced carrier-based pulse width modulation scheme.This approach efficiently balances capacitor voltage,minimizes steady-state error,and strongly suppresses both zero and third-order harmonics resulting in reduced total harmonic distortion and enhanced voltage regulation.Additionally,a novel switching algorithm simplifies the design and implementation,further lowering voltage stress across switches.Extensive simulation results validate the performance under various resistive and resistive-inductive load conditions,demonstrating compliance with IEEE-519 THD standards and robust operation under dynamic changes.The proposed sensorless PR-controlled 15-PUC inverter thus offers a compelling,cost-effective solution for efficient power conversion in next-generation renewable energy systems.
基金supported in part by the National Natural Science Foundation of China,Grant/Award Number:62003267the Key Research and Development Program of Shaanxi Province,Grant/Award Number:2023-GHZD-33Open Project of the State Key Laboratory of Intelligent Game,Grant/Award Number:ZBKF-23-05。
文摘To address the issue of instability or even imbalance in the orientation and attitude control of quadrotor unmanned aerial vehicles(QUAVs)under random disturbances,this paper proposes a distributed antidisturbance data-driven event-triggered fusion control method,which achieves efficient fault diagnosis while suppressing random disturbances and mitigating communication conflicts within the QUAV swarm.First,the impact of random disturbances on the UAV swarm is analyzed,and a model for orientation and attitude control of QUAVs under stochastic perturbations is established,with the disturbance gain threshold determined.Second,a fault diagnosis system based on a high-gain observer is designed,constructing a fault gain criterion by integrating orientation and attitude information from QUAVs.Subsequently,a model-free dynamic linearization-based data modeling(MFDLDM)framework is developed using model-free adaptive control,which efficiently fits the nonlinear control model of the QUAV swarm while reducing temporal constraints on control data.On this basis,this paper constructs a distributed data-driven event-triggered controller based on the staggered communication mechanism,which consists of an equivalent QUAV controller and an event-triggered controller,and is able to reduce the communication conflicts while suppressing the influence of random interference.Finally,by incorporating random disturbances into the controller,comparative experiments and physical validations are conducted on the QUAV platforms,fully demonstrating the strong adaptability and robustness of the proposed distributed event-triggered fault-tolerant control system.
文摘Grid-Forming(GFM)converters are prone to fault-induced overcurrent and power angle instability during grid fault-induced voltage sags.To address this,this paper develops a multi-loop coordinated fault ridethrough(FRT)control strategy based on a power outer loop and voltage-current inner loops,aiming to enhance the stability and current-limiting capability of GFM converters during grid fault conditions.During voltage sags,the GFM converter’s voltage source behavior is maintained by dynamically adjusting the reactive power reference to provide voltage support,thereby effectively suppressing the steady-state component of the fault current.To address the active power imbalance induced by voltage sags,a dynamic active power reference correction method based on apparent power is designed to mitigate power angle oscillations and limit transient current.Moreover,an adaptive virtual impedance loop is implemented to enhance dynamic transient current-limiting performance during the fault initiation phase.This approach improves the responsiveness of the inner loop and ensures safe system operation under various fault severities.Under asymmetric fault conditions,a negative-sequence reactive current compensation strategy is incorporated to further suppress negative-sequence voltage and improve voltage symmetry.The proposed control scheme enables coordinated operation of multiple control objectives,including voltage support,current suppression,and power angle stability,across different fault scenarios.Finally,MATLAB/Simulink simulation results validate the effectiveness of the proposed strategy,showcasing its superior performance in current limiting and power angle stability,thereby significantly enhancing the system’s fault ride-through capability.
基金supported by Guangdong Basic and Applied Basic Research Foundation(Nos.2023A1515110824 and 2025A1515011839)Shenzhen Science and Technology Program(No.RCBS20231211090638066).
文摘Understanding water chemistry in karst regions is crucial for improving global water resource management and deepening our knowledge of the biogeochemical cycles shaping these sensitive environments.Despite advance-ments in karst hydrology,significant gaps remain in long-term trends,underlying processes,and quantitative effects of environmental changes.This is especially true in areas like the Wujiang River(WJ)in China,where human activities such as reservoir construction and land use/cover changes have accelerated hydrochemical changes.We combined recent and historical monitoring data to provide a detailed analysis of the spatial and temporal characteristics,evolution,and controlling factors of major ions in WJ.These findings are important for local water management and contribute to global efforts to manage similar karst systems facing human-induced pressures.Our research shows clear seasonal differences in solute concentrations,with higher levels during the dry season.WJ’s water is rich in calcium,with Ca-HCO_(3) ion pairs being the most common.Reservoir monitor-ing stations show much higher levels of NO_(3)^(−)and SO_(4)^(2−)compared to river-type stations,likely due to longer hydraulic retention time and increased acid deposition.The study confirms the significant role of pH and water temperature in rock weathering processes.Land use/cover changes were identified as the primary drivers of solute variations(46.37%),followed by lithology(13.92%)and temperature(8.35%).Over the past two decades,in-tense carbonate weathering has been observed,especially during wet seasons.Among karstic provinces,Guizhou Province stands out with the highest ion concentrations,indicative of its extensive karst coverage and heightened weathering processes.
基金funded by State Grid Corporation of China Central Branch Technology Project(52140024000C).
文摘In wind power transmission via modular multilevel converter based high voltage direct current(MMCHVDC)systems,under traditional control strategies,MMC-HVDCcannot provide inertia support to the receiving-end grid(REG)during disturbances.Moreover,due to the frequency decoupling between the two ends of the MMCHVDC,the sending-end wind farm(SEWF)cannot obtain the frequency variation information of the REG to provide inertia response.Therefore,this paper proposes a novel coordinated source-network-storage inertia control strategy based on wind power transmission via MMC-HVDC system.First,the grid-side MMC station(GS-MMC)maps the frequency variations of the REG to direct current(DC)voltage variations through the frequency mapping control,and uses submodule capacitor energy to provide inertial power.Then,the wind farm-side MMC station(WF-MMC)restores the DC voltage variations to frequency variations through the frequency restoration control and power loss compensation,providing real-time frequency information for the wind farm.Finally,based on real-time frequency information,thewind farmutilizes the rotor kinetic energy and energy storage to provide fast and lasting power support through the wind-storage coordinated inertia control strategy.Meanwhile,when the wind turbines withdraw from the inertia response phase,the energy storage can increase the power output to compensate for the power deficit,preventing secondary frequency drops.Furthermore,this paper uses small-signal analysis to determine the appropriate values for the key parameters of the proposed control strategy.A simulation model of the wind power transmission via MMCHVDC system is built in MATLAB/Simulink environment to validate and evaluate the proposed method.The results show that the proposed coordinated control strategy can effectively improve the system inertia level and avoid the secondary frequency drop under the load sudden increase condition.
基金support by the National Natural Science Foundation of China(Nos.12174379,E31Q02BG)the Chinese Academy of Sciences(Nos.E0SEBB11,E27RBB11)+1 种基金the Innovation Program for Quantum Science and Technology(No.2021ZD0302300)Chinese Academy of Sciences Project for Young Scientists in Basic Research(No.YSBR-090)。
文摘Quantum control allows a wide range of quantum operations employed in molecular physics,nuclear magnetic resonance and quantum information processing.Thanks to the existing microelectronics industry,semiconducting qubits,where quantum information is encoded in spin or charge degree freedom of electrons or nuclei in semiconductor quantum dots,constitute a highly competitive candidate for scalable solid-state quantum technologies.In quantum information processing,advanced control techniques are needed to realize quantum manipulations with both high precision and noise resilience.In this review,we first introduce the basics of various widely-used control methods,including resonant excitation,adabatic passage,shortcuts to adiabaticity,composite pulses,and quantum optimal control.Then we review the practical aspects in applying these methods to realize accurate and robust quantum gates for single semiconductor qubits,such as Loss–DiVincenzo spin qubit,spinglet-triplet qubit,exchange-only qubit and charge qubit.