AIM: To investigate the value of magnetic resonance elastography(MRE) with regard to assessing liver functional reserve.METHODS: Data from inpatients diagnosed with a liver tumor at an interventional radiology departm...AIM: To investigate the value of magnetic resonance elastography(MRE) with regard to assessing liver functional reserve.METHODS: Data from inpatients diagnosed with a liver tumor at an interventional radiology department from July 2013 to June 2014 were analyzed. A 3.0 Tesla magnetic resonance unit was used to scan 32 patients with confirmed diagnoses of hepatocellular carcinoma(HCC); an MRE sequence was added to the protocol, and the data were reconstructed and analyzed by two attending radiologists. Regions of interest were identified in different slices of the non-tumor liver parenchyma to measure average stiffness. In addition, the indocyanine green(ICG) test was performed no more than 1 wk before or after the magnetic resonance examination for all 32 patients; the ICG retention rate at 15 min(ICGR-15) and the ICG plasma clearance rate(ICG-K) were recorded. Correlational analyses were performed between the liver stiffness values and the ICGR-15 as well as between the liver stiffness values and the ICG-K.RESULTS: Magnetic resonance imaging, including an MRE sequence and the ICG test, was performed successfully in all 32 enrolled patients. None of the patients developed complications. The mean ± SD of the elasticity values measured by the two attending radiologists were 4.7 ± 2.2 k Pa and 4.7 ± 2.1 k Pa, respectively. The average liver stiffness value of the non-tumor parenchyma measured using MRE in HCC patients was 4.7 ± 2.2 k Pa. The average ICGR-15 was 0.089 ± 0.077, and the average ICG-K was 0.19 ± 0.07. We found that the liver stiffness value of the non-tumor parenchyma was significantly and positively related to the ICGR-15(r = 0.746, P < 0.01) as well as significantly and negatively related to the ICG-K(r =-0.599, P < 0.01). The ICGR-15 was significantly and negatively related to the ICG-K(r =-0.852, P < 0.01).CONCLUSION: MRE is accurate and non-invasive; furthermore, it can be used to effectively assess the liver functional reserve of HCC patients.展开更多
基金Supported by Health and Family Planning Commission of Zhejiang Province in China(partly)
文摘AIM: To investigate the value of magnetic resonance elastography(MRE) with regard to assessing liver functional reserve.METHODS: Data from inpatients diagnosed with a liver tumor at an interventional radiology department from July 2013 to June 2014 were analyzed. A 3.0 Tesla magnetic resonance unit was used to scan 32 patients with confirmed diagnoses of hepatocellular carcinoma(HCC); an MRE sequence was added to the protocol, and the data were reconstructed and analyzed by two attending radiologists. Regions of interest were identified in different slices of the non-tumor liver parenchyma to measure average stiffness. In addition, the indocyanine green(ICG) test was performed no more than 1 wk before or after the magnetic resonance examination for all 32 patients; the ICG retention rate at 15 min(ICGR-15) and the ICG plasma clearance rate(ICG-K) were recorded. Correlational analyses were performed between the liver stiffness values and the ICGR-15 as well as between the liver stiffness values and the ICG-K.RESULTS: Magnetic resonance imaging, including an MRE sequence and the ICG test, was performed successfully in all 32 enrolled patients. None of the patients developed complications. The mean ± SD of the elasticity values measured by the two attending radiologists were 4.7 ± 2.2 k Pa and 4.7 ± 2.1 k Pa, respectively. The average liver stiffness value of the non-tumor parenchyma measured using MRE in HCC patients was 4.7 ± 2.2 k Pa. The average ICGR-15 was 0.089 ± 0.077, and the average ICG-K was 0.19 ± 0.07. We found that the liver stiffness value of the non-tumor parenchyma was significantly and positively related to the ICGR-15(r = 0.746, P < 0.01) as well as significantly and negatively related to the ICG-K(r =-0.599, P < 0.01). The ICGR-15 was significantly and negatively related to the ICG-K(r =-0.852, P < 0.01).CONCLUSION: MRE is accurate and non-invasive; furthermore, it can be used to effectively assess the liver functional reserve of HCC patients.