This paper mainly concentrates on design of improved controller and its implementation based on single phase synchronous reference frame theory (SRFT) for Dynamic Voltage Restorer (DVR) compensating voltage sag partic...This paper mainly concentrates on design of improved controller and its implementation based on single phase synchronous reference frame theory (SRFT) for Dynamic Voltage Restorer (DVR) compensating voltage sag particularly for nonlinear load. In case of single phase distribution line with nonlinear load, the complexity of controller’s design becomes more serious issue. The present single phase and/or three phase theories applicable to DVR shows poor response to restore voltage sag in case of nonlinear load due to presence of harmonics. Hence restoration of voltage sag in single phase nonlinear load connected system has been a serious concern. Therefore, new controller for DVR has been proposed incorporating effective design concept for fundamental component extraction in case of nonlinear load. The single phase SRFT based main controller for DVR works on two separate closed path viz. feed forward path for quick transient response and feedback path for reducing the steady state error. Moreover, pre-sag mitigation strategy of DVR has been adapted through these two aforementioned paths. Complete design of proposed controller is based on phasor analysis. It also consist of proportional integral (PI) controller to reduce the error in the DC-link voltage during compensation time. The controller performance has been verified in MATLAB Simulink for both types (linear and nonlinear) of load. The results obtained indicates that the proposed controller is effective in its performance.展开更多
Rainfall is an important factor in estimating the event mean concentration (EMC) which is used to quantify the washed-off pollutant concentrations from non-point sources (NPSs). Pollutant loads could also be calcu...Rainfall is an important factor in estimating the event mean concentration (EMC) which is used to quantify the washed-off pollutant concentrations from non-point sources (NPSs). Pollutant loads could also be calculated using rainfall, catchment area and runoff coefficient. In this study, runoff quantity and quality data gathered from a 28-month monitoring conducted on the road and parking lot sites in Korea were evaluated using multiple linear regression (MLR) to develop equations for estimating pollutant loads and EMCs as a function of rainfall variables. The results revealed that total event rainfall and average rainfall intensity are possible predictors of pollutant loads. Overall, the models are indicators of the high uncertainties of NPSs; perhaps estimation of EMCs and loads could be accurately obtained by means of water quality sampling or a long term monitoring is needed to gather more data that can be used for the development of estimation models.展开更多
This paper presents an analysis to forecast the loads of an isolated area where the history of load is not available or the history may not represent the realistic demand of electricity. The analysis is done through l...This paper presents an analysis to forecast the loads of an isolated area where the history of load is not available or the history may not represent the realistic demand of electricity. The analysis is done through linear regression and based on the identification of factors on which electrical load growth depends. To determine the identification factors, areas are selected whose histories of load growth rate known and the load growth deciding factors are similar to those of the isolated area. The proposed analysis is applied to an isolated area of Bangladesh, called Swandip where a past history of electrical load demand is not available and also there is no possibility of connecting the area with the main land grid system.展开更多
<span style="font-family:Verdana;">This study presents an intelligent approach for load frequency control (LFC) of small hydropower plants (SHPs). The approach which is based on fuzzy logic (FL), takes...<span style="font-family:Verdana;">This study presents an intelligent approach for load frequency control (LFC) of small hydropower plants (SHPs). The approach which is based on fuzzy logic (FL), takes into account the non-linearity of SHPs—something which is not possible using traditional controllers. Most intelligent methods use two-</span><span style="font-family:;" "=""> </span><span style="font-family:;" "=""><span style="font-family:Verdana;">input fuzzy controllers, but because such controllers are expensive, there is </span><span style="font-family:Verdana;">economic interest in the relatively cheaper single-input controllers. A n</span><span style="font-family:Verdana;">on-</span></span><span style="font-family:;" "=""> </span><span style="font-family:Verdana;">linear control model based on one-input fuzzy logic PI (FLPI) controller was developed and applied to control the non-linear SHP. Using MATLAB/Si</span><span style="font-family:Verdana;">- </span><span style="font-family:Verdana;">mulink SimScape, the SHP was simulated with linear and non-linear plant models. The performance of the FLPI controller was investigated and compared with that of the conventional PI/PID controller. Results show that the settling time for the FLPI controller is about 8 times shorter;while the overshoot is about 15 times smaller compared to the conventional PI/PID controller. Therefore, the FLPI controller performs better than the conventional PI/PID controller not only in meeting the LFC control objective but also in ensuring increased dynamic stability of SHPs.</span>展开更多
A theoretical rigid-plastic analysis for the dynamic shear failure of beams under impulsive loading is presented when using a travelling plastic shear hinge model which tabes into account material strain hardening. Th...A theoretical rigid-plastic analysis for the dynamic shear failure of beams under impulsive loading is presented when using a travelling plastic shear hinge model which tabes into account material strain hardening. The maximum dynamic shear strain and shear strain-rate can be predicted in addition to the permanent transverse deflections and other parameters. The conditions for the three modes of shear failure, i.e., excess deflection failure, excess shear strain failure and adiabatic shear failure are analyzed. The special case of an infinitesimally small plastic zone is discussed and compared with Nonaka's solution for a rigid, perfectly plastic material. The results can also be generalized to examine the dynamic response of fibre-reinforced beams.展开更多
The non-linear dynamic behaviors of thermoelastic circular plate with varying thickness subjected to radially uniformly distributed follower forces are considered. Two coupled non-linear differential equations of moti...The non-linear dynamic behaviors of thermoelastic circular plate with varying thickness subjected to radially uniformly distributed follower forces are considered. Two coupled non-linear differential equations of motion for this problem are derived in terms of the transverse deflection and radial displacement component of the mid-plane of the plate. Using the Kantorovich averaging method, the differential equation of mode shape of the plate is derived, and the eigenvalue problem is solved by using shooting method. The eigencurves for frequencies and critical loads of the circular plate with unmovable simply supported edge and clamped edge are obtained. The effects of the variation of thickness and temperature on the frequencies and critical loads of the thermoelastic circular plate subjected to radially uniformly distributed follower forces are then discussed.展开更多
为提高微电网的供电可靠率和能源利用率,提出一种计及分时电价的日前经济优化调度方法。首先建立光伏、储能(energy storage system,ESS)、电动汽车(electric vehicles,EV)等主体的功率或能量模型,然后分别采用光伏功率模型及双向长短...为提高微电网的供电可靠率和能源利用率,提出一种计及分时电价的日前经济优化调度方法。首先建立光伏、储能(energy storage system,ESS)、电动汽车(electric vehicles,EV)等主体的功率或能量模型,然后分别采用光伏功率模型及双向长短期记忆(bidirectional long short term memory,Bi-LSTM)模型预测日内光伏及常规负荷功率。结合EV的柔性负荷特性,以最小化系统运维总成本(包括设备运维成本、外网取电成本、储能电池衰减成本等)及EV充电成本建立目标函数。考虑优化问题的多目标、高维特性,选用线性规划求解器求解目标函数。最后选取含光-储-充的某工业园区微电网2021年全年的历史运行数据,首先测试了本文提出的常规负荷及光伏功率预测模型,进而根据光伏出力与常规负荷的匹配差异,选取4种典型日场景测试本文提出的调控算法。结果证明所提功率预测模型及经济调度算法的有效性。展开更多
提出了一种基于改进线性扩张状态观测器(linear extended state observer,LESO)的电力电子负载自抗扰控制策略,解决了传统控制方法动态性能较差、对系统参数依赖等问题。建立LCL(line current loop)变换器在α-β坐标系下的数学模型,分...提出了一种基于改进线性扩张状态观测器(linear extended state observer,LESO)的电力电子负载自抗扰控制策略,解决了传统控制方法动态性能较差、对系统参数依赖等问题。建立LCL(line current loop)变换器在α-β坐标系下的数学模型,分析线性自抗扰控制(linear active disturbance rejection control,LADRC)中LESO的误差,对观测器控制输出部分的结构进行改进,以减小观测值中来自控制输出信号的误差。通过LESO求取指令电流微分,引入线性误差反馈控制率中,减小传统LADRC的固有误差。分析系统的频域特性,研究参数和控制策略对系统的影响。通过仿真和半实物仿真,验证了改进策略能明显改善传统LADRC跟踪动态信号时的波形畸变、相位滞后等问题,使变换器实现对各类负载的精确模拟。展开更多
文摘This paper mainly concentrates on design of improved controller and its implementation based on single phase synchronous reference frame theory (SRFT) for Dynamic Voltage Restorer (DVR) compensating voltage sag particularly for nonlinear load. In case of single phase distribution line with nonlinear load, the complexity of controller’s design becomes more serious issue. The present single phase and/or three phase theories applicable to DVR shows poor response to restore voltage sag in case of nonlinear load due to presence of harmonics. Hence restoration of voltage sag in single phase nonlinear load connected system has been a serious concern. Therefore, new controller for DVR has been proposed incorporating effective design concept for fundamental component extraction in case of nonlinear load. The single phase SRFT based main controller for DVR works on two separate closed path viz. feed forward path for quick transient response and feedback path for reducing the steady state error. Moreover, pre-sag mitigation strategy of DVR has been adapted through these two aforementioned paths. Complete design of proposed controller is based on phasor analysis. It also consist of proportional integral (PI) controller to reduce the error in the DC-link voltage during compensation time. The controller performance has been verified in MATLAB Simulink for both types (linear and nonlinear) of load. The results obtained indicates that the proposed controller is effective in its performance.
基金provided by the Korean Ministry of Environment and Eco Star Project
文摘Rainfall is an important factor in estimating the event mean concentration (EMC) which is used to quantify the washed-off pollutant concentrations from non-point sources (NPSs). Pollutant loads could also be calculated using rainfall, catchment area and runoff coefficient. In this study, runoff quantity and quality data gathered from a 28-month monitoring conducted on the road and parking lot sites in Korea were evaluated using multiple linear regression (MLR) to develop equations for estimating pollutant loads and EMCs as a function of rainfall variables. The results revealed that total event rainfall and average rainfall intensity are possible predictors of pollutant loads. Overall, the models are indicators of the high uncertainties of NPSs; perhaps estimation of EMCs and loads could be accurately obtained by means of water quality sampling or a long term monitoring is needed to gather more data that can be used for the development of estimation models.
文摘This paper presents an analysis to forecast the loads of an isolated area where the history of load is not available or the history may not represent the realistic demand of electricity. The analysis is done through linear regression and based on the identification of factors on which electrical load growth depends. To determine the identification factors, areas are selected whose histories of load growth rate known and the load growth deciding factors are similar to those of the isolated area. The proposed analysis is applied to an isolated area of Bangladesh, called Swandip where a past history of electrical load demand is not available and also there is no possibility of connecting the area with the main land grid system.
文摘<span style="font-family:Verdana;">This study presents an intelligent approach for load frequency control (LFC) of small hydropower plants (SHPs). The approach which is based on fuzzy logic (FL), takes into account the non-linearity of SHPs—something which is not possible using traditional controllers. Most intelligent methods use two-</span><span style="font-family:;" "=""> </span><span style="font-family:;" "=""><span style="font-family:Verdana;">input fuzzy controllers, but because such controllers are expensive, there is </span><span style="font-family:Verdana;">economic interest in the relatively cheaper single-input controllers. A n</span><span style="font-family:Verdana;">on-</span></span><span style="font-family:;" "=""> </span><span style="font-family:Verdana;">linear control model based on one-input fuzzy logic PI (FLPI) controller was developed and applied to control the non-linear SHP. Using MATLAB/Si</span><span style="font-family:Verdana;">- </span><span style="font-family:Verdana;">mulink SimScape, the SHP was simulated with linear and non-linear plant models. The performance of the FLPI controller was investigated and compared with that of the conventional PI/PID controller. Results show that the settling time for the FLPI controller is about 8 times shorter;while the overshoot is about 15 times smaller compared to the conventional PI/PID controller. Therefore, the FLPI controller performs better than the conventional PI/PID controller not only in meeting the LFC control objective but also in ensuring increased dynamic stability of SHPs.</span>
文摘A theoretical rigid-plastic analysis for the dynamic shear failure of beams under impulsive loading is presented when using a travelling plastic shear hinge model which tabes into account material strain hardening. The maximum dynamic shear strain and shear strain-rate can be predicted in addition to the permanent transverse deflections and other parameters. The conditions for the three modes of shear failure, i.e., excess deflection failure, excess shear strain failure and adiabatic shear failure are analyzed. The special case of an infinitesimally small plastic zone is discussed and compared with Nonaka's solution for a rigid, perfectly plastic material. The results can also be generalized to examine the dynamic response of fibre-reinforced beams.
基金Natural Science Research Project of Education Department of Shaanxi Province,China(No.08JK394).
文摘The non-linear dynamic behaviors of thermoelastic circular plate with varying thickness subjected to radially uniformly distributed follower forces are considered. Two coupled non-linear differential equations of motion for this problem are derived in terms of the transverse deflection and radial displacement component of the mid-plane of the plate. Using the Kantorovich averaging method, the differential equation of mode shape of the plate is derived, and the eigenvalue problem is solved by using shooting method. The eigencurves for frequencies and critical loads of the circular plate with unmovable simply supported edge and clamped edge are obtained. The effects of the variation of thickness and temperature on the frequencies and critical loads of the thermoelastic circular plate subjected to radially uniformly distributed follower forces are then discussed.
文摘为提高微电网的供电可靠率和能源利用率,提出一种计及分时电价的日前经济优化调度方法。首先建立光伏、储能(energy storage system,ESS)、电动汽车(electric vehicles,EV)等主体的功率或能量模型,然后分别采用光伏功率模型及双向长短期记忆(bidirectional long short term memory,Bi-LSTM)模型预测日内光伏及常规负荷功率。结合EV的柔性负荷特性,以最小化系统运维总成本(包括设备运维成本、外网取电成本、储能电池衰减成本等)及EV充电成本建立目标函数。考虑优化问题的多目标、高维特性,选用线性规划求解器求解目标函数。最后选取含光-储-充的某工业园区微电网2021年全年的历史运行数据,首先测试了本文提出的常规负荷及光伏功率预测模型,进而根据光伏出力与常规负荷的匹配差异,选取4种典型日场景测试本文提出的调控算法。结果证明所提功率预测模型及经济调度算法的有效性。
文摘提出了一种基于改进线性扩张状态观测器(linear extended state observer,LESO)的电力电子负载自抗扰控制策略,解决了传统控制方法动态性能较差、对系统参数依赖等问题。建立LCL(line current loop)变换器在α-β坐标系下的数学模型,分析线性自抗扰控制(linear active disturbance rejection control,LADRC)中LESO的误差,对观测器控制输出部分的结构进行改进,以减小观测值中来自控制输出信号的误差。通过LESO求取指令电流微分,引入线性误差反馈控制率中,减小传统LADRC的固有误差。分析系统的频域特性,研究参数和控制策略对系统的影响。通过仿真和半实物仿真,验证了改进策略能明显改善传统LADRC跟踪动态信号时的波形畸变、相位滞后等问题,使变换器实现对各类负载的精确模拟。