期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Online Identification Method of Distribution Line-to-ground Parameters and Grounding Tran-sition Conductance During Arc Suppression 被引量:1
1
作者 Zeyin Zheng Jianfeng Xu Moufa Guo 《Protection and Control of Modern Power Systems》 2025年第4期103-115,共13页
Since the effectiveness of the flexible current arc suppression method heavily relies on the accurate measurement of the distribution line-to-ground parame-ters,the suppression of single line-to-ground(SLG)fault curre... Since the effectiveness of the flexible current arc suppression method heavily relies on the accurate measurement of the distribution line-to-ground parame-ters,the suppression of single line-to-ground(SLG)fault current may deteriorate due to factors such as line switching and other disturbances during SLG fault arc suppression.Additionally,during SLG fault arc suppres-sion,promptly identifying the fault type and rapidly de-activating the flexible arc suppression device(FASD)can reduce the overvoltage risk in non-faulted phase devices.To address these issues,this paper presents a parameter identification method based on recursive least squares(RLS)while a variable forgetting factor strategy is in-troduces to enhance the RLS algorithm’s disturbance rejection capability.Simulations verify that the variable forgetting factor recursive least squares(VFF-RLS)algo-rithm can accurately identify distribution line-to-ground parameters in real time and effectively suppress SLG fault current.The online identification of grounding transition conductance is simultaneously used to deter-mine the fault type and quickly detect when the SLG fault has been cleared. 展开更多
关键词 Distribution networks single line-to-ground fault arc suppression distribution line-to-ground parameters grounding transition conduct-ance recursive least square method online identification
在线阅读 下载PDF
On-Line Fault Diagnosis and Fault-Tolerant Operation of Modular Multilevel Converters –A Comprehensive Review 被引量:11
2
作者 JiangBiao He Qichen Yang Zheng Wang 《CES Transactions on Electrical Machines and Systems》 CSCD 2020年第4期360-372,共13页
Modular multilevel converters(MMCs)have been one of the most broadly used multilevel converter topologies in industrial applications,particularly in medium-voltage motor drives and high-voltage dc power conversion sys... Modular multilevel converters(MMCs)have been one of the most broadly used multilevel converter topologies in industrial applications,particularly in medium-voltage motor drives and high-voltage dc power conversion systems.However,due to the utilization of large amount of semiconductor devices,the reliability of MMCs becomes one of the severe challenges constraining their further development and applications.In this paper,common electrical faults of the MMC have been summarized and analyzed,including open-circuit switching faults,short-circuit switching faults,dc-bus short-circuit faults,and single line-to-ground faults on the ac side.A thorough and comprehensive review of the existing online fault diagnostic methods has been conducted.In addition,fault-tolerant operation strategies for such various fault scenarios in MMCs have been presented.All the fault diagnosis and fault-tolerant operation strategies are comparatively evaluated,which aims to provide a state-of-the-art reference on the MMC reliability for future research and industrial applications. 展开更多
关键词 Modular multilevel converters switching open-circuit fault line-to-ground fault diagnosis fault tolerance
在线阅读 下载PDF
Research on Total Electric Field for DC Lines Converted from Double-Circuit AC Lines
3
作者 Xiaoqian Ma Jiayu Lu +1 位作者 Kun He Wensheng Gao 《Energy and Power Engineering》 2017年第4期598-610,共13页
With rapid growth of power demand, transmission capacity is also in urgent need of upgrading. In some cases, converting existing AC transmission lines to DC lines can Improve the transmission capacity and reduce the c... With rapid growth of power demand, transmission capacity is also in urgent need of upgrading. In some cases, converting existing AC transmission lines to DC lines can Improve the transmission capacity and reduce the construction investment. In this paper, the upstream finite element method was expanded to calculate the total electric field of same tower multi-circuit DC lines converted from double-circuit AC lines, and the validity of the algorithm was confirmed by experiments. Taking a DC line converted from a typical same tower 500 kV double-circuit AC transmission line as an example, the surface electric field and the ground total electric field in different pole conductor arrangement schemes were calculated and analyzed, and the critical height of pole conductors for DC lines in residential and non-residential area were determined. Then, the corridor width of DC and AC lines at critical height in residential and non-residential areas before and after AC-DC line transformation were compared. The results indicate that for DC lines converted from common 500 kV double-circuit AC lines, the ground total electric field can meet the requirements of corresponding standard with appropriate pole conductor arrangement schemes. 展开更多
关键词 DC LINES Converted from AC LINES Multi-Circuit DC LINE at SAME Tower Pole Conductor BUNDLES Arrangement Scheme Total Electric Field line-to-ground Distance Corridor Width
暂未订购
上一页 1 下一页 到第
使用帮助 返回顶部