AIM:To evaluate and compare alterations in the effective lens position(ELP)and refractive outcomes among three distinct intraocular lens(IOL)types.METHODS:Patients with cataracts were enrolled and allocated to 3 group...AIM:To evaluate and compare alterations in the effective lens position(ELP)and refractive outcomes among three distinct intraocular lens(IOL)types.METHODS:Patients with cataracts were enrolled and allocated to 3 groups:Group A(implanted with the SN6CWS),Group B(implanted with the MI60),and Group C(implanted with the Aspira-aA).ELP measurements were obtained with swept-source optical coherence tomography(SS-OCT)at 1d,1wk,1mo,and 3mo postoperatively.Subjective refraction assessments were conducted at 1wk,1mo,and 3mo following surgery.RESULTS:The study included 189 eyes of 150 cataract patients(66 males).There were 77 eyes in Group A,55 eyes in Group B,and 57 eyes in Group C.The root mean square of the ELP(ELPRMS)within the initial 3mo was significantly lower for Group A than for Groups B and C.Refractive changes within Group A were not significant across the time points of 1wk,1mo,and 3mo.Conversely,both Group B and Group C demonstrated statistically significant shifts toward hyperopia from 1wk to 3mo postsurgery.CONCLUSION:Among the three IOLs examined,the SN6CWS IOL showes the greatest stability during the first 3mo postoperatively.Between 1wk and 3mo after surgery,notable hyperopic shifts are evident in eyes implanted with the MI60 and Aspira-aA IOLs,whereas refractive outcomes remain relatively constant in eyes implanted with SN6CWS IOLs.展开更多
AIM:To investigate age-related differences in the irislens angle(ILA)among patients with age-related cortical cataracts and elucidate the impact of age on lens stability.METHODS:A prospective observational study was c...AIM:To investigate age-related differences in the irislens angle(ILA)among patients with age-related cortical cataracts and elucidate the impact of age on lens stability.METHODS:A prospective observational study was conducted on patients with age-related cortical cataracts scheduled for phacoemulsification surgery.Preoperative ultrasound biomicroscopy(UBM)images were collected and analyzed.Initially,patients were stratified into two age groups:<60y and≥60y,with no significant intergroup differences in sex or eye laterality.For further analysis,participants were subdivided into three age strata:<60y,60-75y,and>75y.The ILA was measured in four quadrants(superior,inferior,nasal,and temporal).Intergroup differences in ILA were compared,and correlations between age and ILA parameters were analyzed using statistical methods.RESULTS:The sample data were categorized into three groups according to age,<60y(113 patients;55.8%female),60–75y(245 patients;61.0%female),and>75y(70 patients;50.2%female).The superior quadrant ILA increased progressively with age stratification(P=0.02),and the maximum ILA difference(ΔILA)was significantly higher in patients over 75y(P<0.01).Simple linear regression analysis demonstrated a positive correlation between age and ILA in the superior(Y=7.487+0.096X,R=0.191,P<0.001)and temporal(Y=10.254+0.052X,R=0.104,P=0.032)quadrants.Additionally,the mean ILA across all quadrants(ILAmean)andΔILA were positively correlated with age(ILAmean:Y=9.721+0.055X,R=0.138,P=0.004;ΔILA:Y=3.267+0.044X,R=0.006,P<0.05).CONCLUSION:In patients with age-related cortical cataracts,ILA increases with age,particularly in the superior and temporal quadrants,suggesting that advanced age is associated with greater lens deviation and decreased lens stability.UBM imaging can effectively evaluate the status of the zonule and lens stability,providing crucial evidence for personalized surgical planning based on patients’age.展开更多
MXene-based smart contact lenses demonstrate a cutting-edge advancement in wearable ophthalmic technology,combining real-time biosensing,therapeutic capabilities,and user comfort in a single platform.These devices tak...MXene-based smart contact lenses demonstrate a cutting-edge advancement in wearable ophthalmic technology,combining real-time biosensing,therapeutic capabilities,and user comfort in a single platform.These devices take the advantage of the exceptional electrical conductivity,mechanical flexibility,and biocompatibility of two-dimensional MXenes to enable noninvasive,tear-based monitoring of key physiological markers such as intraocular pressure and glucose levels.Recent developments focus on the integration of transparent MXene films into the conventional lens materials,allowing multifunctional performance including photothermal therapy,antimicrobial and anti-inflammation protection,and dehydration resistance.These innovations offer promising strategies for ocular disease management and eye protection.In addition to their multifunctionality,improvements in MXene synthesis and device engineering have enhanced the stability,transparency,and wearability of these lenses.Despite these advances,challenges remain in long-term biostability,scalable production,and integration with wireless communication systems.This review summarizes the current progress,key challenges,and future directions of MXene-based smart contact lenses,highlighting their transformative potential in next-generation digital healthcare and ophthalmic care.展开更多
AIM:To investigate the characteristics and associated factors of intraocular lens(IOL)tilt and decentration after transscleral suture-fixated IOL surgery in congenital ectopia lentis(CEL).METHODS:CEL patients undergoi...AIM:To investigate the characteristics and associated factors of intraocular lens(IOL)tilt and decentration after transscleral suture-fixated IOL surgery in congenital ectopia lentis(CEL).METHODS:CEL patients undergoing transscleral suture-fixated IOL surgery were divided into two groups based on implanted IOL type(three-piece IOL or one-piece IOL).The IOL tilt and decentration at 3-month and 1-year postoperative were measured.Multivariate regression analyses were performed to identify the associated factors of IOL tilt and decentration as well as longitudinal changes.RESULTS:The 61 CEL patients(mean age 9.07±5.05y)in three-piece IOL(M/F:14/7)group had a greater tilt than those with one-piece IOL(M/F:28/12)group both at 3-month postoperative(horizontal:P=0.024;vertical:P=0.048)and 1-year postoperative(horizontal:P=0.011;vertical:P=0.001).Three-piece IOL group had a greater longitudinal change between 3-month postoperative to 1-year postoperative in IOL tilt(horizontal:P=0.028;vertical:P=0.026)and a greater longitudinal change in horizontal IOL decentration than one-piece IOL group(P<0.05).The longer axial length(AL)was associated with the longitudinal changes in IOL tilt(P=0.039),while the three-piece IOL was associated with the longitudinal changes in horizontal IOL decentration 1-year postoperatively(P=0.011).CONCLUSION:IOL tilt is greater in the three-piece IOL group than that in the one-piece IOL group 1-year postoperatively.The three-piece IOL is associated with greater longitudinal changes of IOL decentration,while longer AL is associated with longitudinal changes of IOL tilt.For CEL patients,more stable IOL type should be selected and patients with longer AL warrant closer monitoring.展开更多
AIM:To evaluate the differences and consistency of vault measurements obtained by Scheimpflug tomography(Pentacam),anterior segment optical coherence tomography(AS-OCT,CASIA II),and ultrasound biomicroscopy(UBM)follow...AIM:To evaluate the differences and consistency of vault measurements obtained by Scheimpflug tomography(Pentacam),anterior segment optical coherence tomography(AS-OCT,CASIA II),and ultrasound biomicroscopy(UBM)following implantable collamer lens(ICL)V4c implantation.METHODS:Vault measurements were acquired using three modalities:Pentacam,CASIA II AS-OCT,and UBM.Repeated-measures analysis of variance was used to compare the vault values obtained by the three devices.The correlation and consistency of measurements among the three instruments were assessed using the Pearson correlation coefficient,intraclass correlation coefficient(ICC),and Bland-Altman plots.RESULTS:This retrospective study enrolled 210 myopic eyes of 210 patients(158 women and 52 men)who underwent ICL implantation:108 eyes had a myopic ICL V4c implanted,and 102 eyes had a toric ICL V4c implanted.The mean vault values measured by Pentacam,CASIA II,and UBM were 452.64±204.20μm,538.57±203.54μm,and 560.95±227.54μm,respectively,with statistically significant differences among the three groups(P<0.05).Pearson correlation analysis showed strong positive correlations between vault values measured by different instruments(all P<0.001).ICC results indicated good consistency among the three measurement modalities(all P<0.001).Stratified analysis revealed that when the vault value was≤250μm,the correlation and consistency of measurements across the three instruments were lower than those in the medium and high vault subgroups.CONCLUSION:Vault values measured by Pentacam are lower than those obtained by CASIA II and UBM,with UBM yielding the highest mean vault values.Measurements from the three instruments are not interchangeable but can serve as mutual references due to their significant correlation and good overall consistency.Pentacam and CASIA II demonstrate the highest consistency in vault measurement.Notably,when the vault value is≤250μm,the consistency between Pentacam and the other two instruments decreases significantly.展开更多
AIM:To investigate the long-term outcomes in acute primary angle closure(APAC)patients treated with lens extraction(LE)surgery and to identify risk factors for glaucomatous optic neuropathy(GON).METHODS:In this longit...AIM:To investigate the long-term outcomes in acute primary angle closure(APAC)patients treated with lens extraction(LE)surgery and to identify risk factors for glaucomatous optic neuropathy(GON).METHODS:In this longitudinal observational study,detailed medical histories of APAC patients and comprehensive ophthalmic examinations at final followup were collected.Logistic regression analysis was performed to identify predictors of blindness.Univariate and multivariate linear regression analyses were conducted to determine risk factors associated with visual outcomes.RESULTS:This study included 39 affected eyes of 31 subjects(26 females)with an average age of 74.1±8.0y.At 6.7±4.2y after APAC attack,2(5.7%)eyes had bestcorrected visual acuity(VA)worse than 3/60.Advanced glaucomatous visual field loss was observed in 15(39.5%)affected eyes and 5(25.0%)fellow eyes.Nine affected eyes(23.7%)had GON,and 11(28.9%)were blind.Six(15.4%)affected eyes and 2(9.1%)fellow eyes had suspicious progression.A significantly higher blindness rate in factory workers compared to office workers.Logistic regression identified that worse VA at attack(OR 10.568,95%CI 1.288-86.695;P=0.028)and worse early postoperative VA(OR 13.214,95%CI 1.157-150.881;P=0.038)were risk factors for blindness.Multivariate regression showed that longer duration of elevated intraocular pressure(P=0.004)and worse early postoperative VA(P=0.009)were associated with worse visual outcomes.CONCLUSION:Despite LE surgery,some APAC patients experience continued visual function deterioration.Lifelong monitoring is necessary.Target pressure and progression rates should be re-evaluated during follow-up.展开更多
Ice lens initiation is the core issue in understanding the dynamic process of frost heave.However,there are still limitations to find an adequate criterion for describing the formation of ice lens.A series of one-dime...Ice lens initiation is the core issue in understanding the dynamic process of frost heave.However,there are still limitations to find an adequate criterion for describing the formation of ice lens.A series of one-dimensional freezing tests is designed using the particle image velocimetry(PIV)method to monitor the frost heave and ice lens formation.The results show that the conventional parameters,such as displacement and velocity,cannot be used to track the ice lens formation,while the strain can be employed to detect the ice lens formation and investigate the freezing change patterns.This study proposes strain as a new criterion for assessing ice lens initiation,applicable across various soil types and freezing conditions(constant freezing and ramped freezing).The strain change in the region where the ice lens forms is the largest during the freezing process.Additionally,strain curves at the top of the soil samples can reveal different freezing patterns and distinguish the first and second frost heave stages.This newly developed technology enables continuous,non-destructive monitoring of ice lens initiation across diverse conditions and soil types,enhancing data visualization and three-dimensional modeling of freezing parameters while improving traditional methods by directly measuring velocity and strain in frost heave investigations.The study is expected to enhance the research of ice lens criterion and provide a new perspective for monitoring the freezing process.展开更多
The manipulation of intense shock waves to either attenuate or enhance damage has long been a key goal in the domain of impact dynamics.Effective methods for such manipulation,however,remain elusive owing to the wide ...The manipulation of intense shock waves to either attenuate or enhance damage has long been a key goal in the domain of impact dynamics.Effective methods for such manipulation,however,remain elusive owing to the wide spectrum and irreversible destructive nature of intense shock waves.This work proposes a novel approach for actively controlling intense shock waves in solids,inspired by the principles of optical and explosive lenses.Specifically,by designing a shock wave convex lens composed of a low-shock-impedance material embedded in a high-shock-impedance matrix,we prove the feasibility of transforming a planar shock into a spherically converging shock.This is based on oblique shock theory,according to which shock waves pass through an oblique interface and then undergo deflection.Both experimental and simulation results demonstrate that,as expected,the obtained local spherical shock wave has a wavefront that is nearly perfectly spherical and uniform in pressure.Thus,this work proves the possibility of generating spherical shock waves using plate-impact experiments and highlights the potential of further exploration of the manipulation of shock waves in solids.It also contributes an innovative perspective for both armor penetration technologies and shock wave mitigation strategies.展开更多
Flat lenses,including metalenses and diffractive lenses,have attracted considerable attention for enabling miniaturized optical systems.However,achieving large-scale flat lenses with both a large numerical aperture(NA...Flat lenses,including metalenses and diffractive lenses,have attracted considerable attention for enabling miniaturized optical systems.However,achieving large-scale flat lenses with both a large numerical aperture(NA)and high achromatic performance remains a significant challenge.In this work,we propose a structural height optimization method named focal phasor matching to achieve high-performance designs for large apertures.展开更多
Dear Editor,The latest Visian implantable collamer lens(ICL)with a central port design(Aquaport;model V4c)obviates the necessity for preoperative laser iridotomy or intraoperative iridectomy by allowing the free flow ...Dear Editor,The latest Visian implantable collamer lens(ICL)with a central port design(Aquaport;model V4c)obviates the necessity for preoperative laser iridotomy or intraoperative iridectomy by allowing the free flow of the aqueous humor between the sides of the intraocular lens.The design of Aquaport can also eliminate the complications associated with iridotomy and iridectomy.Therefore,the V4c ICL has the potential to significantly reduce the risk of pupillary block compared to its predecessors.展开更多
At present,the naked-eye three-dimensional(3D)display technology still has some drawbacks,such as low brightness uniformity,high crosstalk,low light efficiency,short viewing distance,and the manufacturing is difficult...At present,the naked-eye three-dimensional(3D)display technology still has some drawbacks,such as low brightness uniformity,high crosstalk,low light efficiency,short viewing distance,and the manufacturing is difficulty.Based on the principle of naked-eye 3D display and the Fresnel optical theory,this paper designs a Fresnel lens array and the star-shaped liquid crystal display(LCD)switch of unit LCD screen to achieve low-crosstalk and high brightness uniformity for the autostereoscopic 3D display.The unit parameters of a 139.7 cm 4K model autostereoscopic 3D displayer are provided and they are optimized by the TracePro software.The results show that when the pitch of the Fresnel lens on the exit surface is 0.304 mm,the width of each serration of Fresnel lens is 0.0234 mm,the length of the Fresnel lens is 2.87 mm,and the center height of star-shaped LCD switch is 0.030 mm,the center length is 0.040 mm,the width of star-shaped LCD switch is 0.050 mm,and the image crosstalk is less than 2%when the viewing distance is 2.50 m.The problem on the brightness of the image in different positions is improved.展开更多
AIM:To assess whether the implantation of a posterior chamber phakic intraocular lens produces changes in optical coherence tomography(OCT)measurements of macular thickness(MT)and two parameters that define the struct...AIM:To assess whether the implantation of a posterior chamber phakic intraocular lens produces changes in optical coherence tomography(OCT)measurements of macular thickness(MT)and two parameters that define the structure of the optic nerve,the peripapillary nerve fiber layer(RNFL)and the Bruch’s membrane opening-minimum rim width(BMO-MRW).METHODS:This nonrandomized prospective pre-post study included 86 eyes of 48 patients(age,20-47y;axial length:23.10-28.95 mm)scheduled for myopia or myopic astigmatism correction with implantation of the implantable collamer lens(ICL).Eyes with glaucoma or any other ocular disease that could alter OCT results were excluded.RNFL,BMO-MRW and MT were measured preoperatively,and at 1 and 6mo after surgery using spectral-domain OCT.Changes between preoperative and postoperative values were evaluated.RESULTS:There was a significant increase in BMOMRW at 1mo(mean change:3.48±15.07μm,P=0.041).No significant changes were found during the rest of followup(1-6mo postop.,P=0.623).There was also a significant increase in RNFL thickness at 1mo af ter surger y(1.45±2.18μm,P<0.001),but with a significant reduction from 1 to 6mo postoperatively(P=0.002).Regarding MT,it increased significantly at 1mo(2.46±3.76μm,P<0.001),with a significant decrease afterwards(P=0.048).Measurements of the three parameters at 6mo were slightly superior to preoperative values(P<0.01).CONCLUSION:Minimal changes are induced in BMOMRW,RNFL and MT after ICL implantation in healthy eyes,confirming the safety of the surgical procedure regarding the structure of the optic nerve head and the macula,and indicating that this phakic intraocular lens seems to have a slight impact on OCT measurements.展开更多
Objective:To evaluate the performance of orthokeratology(ortho-k)lens reordering using software-designed system,so as to determine the feasibility of ortho-k lens reordering without discontinuing lens wear.Methods:Thi...Objective:To evaluate the performance of orthokeratology(ortho-k)lens reordering using software-designed system,so as to determine the feasibility of ortho-k lens reordering without discontinuing lens wear.Methods:This study is a retrospective analysis of data of ortho-k lens wearers who had a history of short-term discontinuation of lens wear.A total of 94 individuals aged over 8 years with spherical equivalent refraction ranging from-0.50 to-6.50 diopters were included.The corneal topography data at baseline(before ortho-k)and after lens wear discontinuation(cessation of ortho-k treatment)were imported separately into the lens-design software,along with corresponding refraction data.Subsequently,corneal and lens parameters were generated and compared.Intraclass correlation coefficients(ICC)were calculated,and Bland and Altman analyses were conducted.Results:All 94 children were involved in the retrospective analysis.Compared with baseline data,there was a high level of consistency between Rwo(without discontinuation)and Rwith(with discontinuation),with an ICC of 0.96(P<0.001).Furthermore,the comparison of lens parameters generated by the Easyfit software between baseline and after short-term discontinuation showed a high degree of consistency,with all of the ICC values exceeding 0.90.Similar results were obtained using the WAVE software,as both ICC values and Bland-Altman plots demonstrated a high level of consistency in lens parameters between two conditions(nearly all data points fell within the 95%LoAs).Conclusions:It is feasible to directly reorder new ortho-k lenses using software fitting approaches.However,further investigations are necessary to validate their practicability in a clinical setting.展开更多
As cataract surgery progresses from “restoration of sight” to “refractive correction”, precise prediction of intraocular lens (IOL) power is critical for enhancing postoperative visual quality in patients. IOL pow...As cataract surgery progresses from “restoration of sight” to “refractive correction”, precise prediction of intraocular lens (IOL) power is critical for enhancing postoperative visual quality in patients. IOL power calculation methods have evolved and innovated throughout time, from early theoretical and regression formulas to nonlinear formulas for estimating effective lens position (ELP), multivariable formulas, and innovative formulas that use optical principles and AI-based online formulas. This paper thoroughly discusses the development and iteration of traditional IOL calculation formulas, the emergence of new IOL calculation formulas, and the selection of IOL calculation formulas for different patients in the era of refractive cataract surgery, serving as a reference for “personalized” IOL implantation in clinical practice.展开更多
Background:The Akreos®AO60 intraocular lens(IOL)has been employed for scleral fixation in eyes without capsular support,although surgical complications,including IOL opacification,have been reported.This study ai...Background:The Akreos®AO60 intraocular lens(IOL)has been employed for scleral fixation in eyes without capsular support,although surgical complications,including IOL opacification,have been reported.This study aims to evaluate the outcomes and complications associated with scleral fixation of the Akreos®AO60 IOL in vitrectomized eyes,with a particular focus on IOL opacification.Methods:Electronic medical records of consecutive eyes that underwent scleral-fixation of the Akreos®AO60 lens using Gore-tex®sutures from 2017 to 2022 were reviewed.The following parameters were collected:age,sex,laterality,past ocular/medical history,surgical indication,pre-operative visual acuity(VA)and intraocular pressure(IOP),surgical procedure,and post-operative VA and IOP.The types of complications,onset,management,and outcomes were also documented.Descriptive statistics,Wilcoxon signed-rank test,and Fisher’s exact test were employed for statistical analysis.Results:Eighty-nine eyes of 86 patients aged 31-100 years were included.The most common surgical indication was non-traumatic IOL displacement.Retinal tears and localized choroidal hemorrhage were found intraoperatively in 7.9%and 1.1%,respectively.The most common post-operative complications were vitreous hemorrhage(13.5%),corneal edema(12.4%),ocular hypotony(11.2%),and IOL opacification(11.2%).IOL opacification was associated with intra-/post-operative exposure to air/gas[odds ratio(OR):12.24;95%confidence interval(CI),1.46-103.0;P=0.006].Mean logarithm of the minimum angle of resolution(logMAR)best-reported VA(BRVA)improved from 1.22±0.77 pre-operatively to 0.56±0.67 on latest follow-up(P<0.001).Conclusions:The majority of the complications from scleral-fixation of the Akreos®AO60 lens in vitrectomized eyes were mild and transient;however,a proportion required surgical intervention.A significant risk for opacification was found in IOLs exposed to air/gas,although VA was often maintained.展开更多
We study the lensing phenomena of the strong gravity regime of five-dimensional charged,equally rotating black holes with a cosmological constant,familiarly known as the Cvetic–Lu–Pope(CLP)black holes.These black ho...We study the lensing phenomena of the strong gravity regime of five-dimensional charged,equally rotating black holes with a cosmological constant,familiarly known as the Cvetic–Lu–Pope(CLP)black holes.These black holes are characterized by three observable parameters,the mass M,the charge Q and the angular momentum J,in addition to the cosmological constant.We investigate the strong gravitational lensing observables,mainly the photon sphere radius,the minimum impact parameter,the deflection angle,the angular size,and the magnification of the relativistic images.We model the M87 and SgrA*for these observables.We also focus on the relativistic time delay effect in the strong-field regime of gravity and the impact of the observable on it.The analytical expressions for the observables of the relativistic images with vanishing angular momentum(j=0)are discussed in some detail.We shed a light on the gravitational time delay effect by incorporating the lensing observables.The gravitational time delay has a direct consequence on the photon sphere radius and hence on the quasinormal modes.展开更多
AIM:To compare the clinical outcomes of extended depth-of-focus intraocular lenses(EDOF IOLs)using either micromonovision implantation or mixed implantation of EDOF and diffractive bifocal IOLs.METHODS:This retrospect...AIM:To compare the clinical outcomes of extended depth-of-focus intraocular lenses(EDOF IOLs)using either micromonovision implantation or mixed implantation of EDOF and diffractive bifocal IOLs.METHODS:This retrospective clinical trial included 130 patients(260 eyes),who were divided into two groups.Group RR comprised 70 patients(140 eyes)bilaterally implanted with ZXR00 IOLs(Tecnis ZXR00,where one target was-0.5 D to-0.75 D and the other was 0 to-0.25 D).Group RM comprised 60 patients(120 eyes)unilaterally implanted with both ZXR00 and ZMB00 IOLs(Tecnis ZMB00,0 to-0.25 D).Postoperative outcomes were compared after 3 mo,including visual acuity,defocus curves,stereoacuity,modulation transfer functions(MTFs),higher-order aberrations,and Visual Function-14(VF-14)questionnaire responses.RESULTS:Group RR had superior bilateral intermediate vision,while the group RM had superior bilateral near vision(both P<0.05).Group RM also exhibited superior MTFs and reduced higher-order aberrations(both P<0.05).Stereoacuity and VF-14 questionnaire results showed no statistically significant difference between groups(P>0.05).CONCLUSION:The implantation of micromonovision has significantly improved near vision.IOLs and their collocation can be customized according to individual patient needs to achieve precise treatment and provide cataract patients with high-quality vision.展开更多
AIM:To evaluate the visual and refractive outcomes in cases after sutured scleral fixation of existing subluxated or dislocated acrylic one-piece intraocular lenses(IOLs).METHODS:This study retrospectively enrolled a ...AIM:To evaluate the visual and refractive outcomes in cases after sutured scleral fixation of existing subluxated or dislocated acrylic one-piece intraocular lenses(IOLs).METHODS:This study retrospectively enrolled a consecutive series of patients who underwent a surgery of sutured existing subluxated or dislocated IOLs from October 2018 to June 2020.All patients underwent comprehensive preoperative and postoperative ophthalmologic examination,and data were collected including age,sex,surgical indications,best-corrected visual acuity,refractive error,intraocular pressure.Presence of intraoperative and postoperative surgical complications was documented.RESULTS:A total of 20 consecutive cases were enrolled for analysis with mean final follow-up period 9.8±5.3mo.Visual acuity improved from a mean of 0.35(0.46±0.32 logMAR)preoperatively to 0.61(0.21±0.18 logMAR)at the 3-month follow-up(P=0.002).The mean amount of preoperative keratometric astigmatism and total postoperative refractive astigmatism was-1.24±0.80 diopters(D)and-1.42±0.97 D,respectively.There was no statistically significant difference between preoperative and postoperative astigmatism(P=0.156).The mean IOL-induced astigmatism was-0.23±0.53 D.The mean spherical equivalent at the 3-month follow-up was-0.1±0.94 D.No major complications were noted during the follow-up period.CONCLUSION:Surgical techniques using sutured scleral fixation of existing subluxated or dislocated acrylic one-piece IOLs result in favorable visual and refractive outcomes without major complications.展开更多
AIM:To assess visual outcomes and satisfaction of a non-diffractive extended depth of focus(EDOF)intraocular lens(IOL)in individuals with ocular hypertension(OHT)and well-controlled mild glaucoma undergoing cataract s...AIM:To assess visual outcomes and satisfaction of a non-diffractive extended depth of focus(EDOF)intraocular lens(IOL)in individuals with ocular hypertension(OHT)and well-controlled mild glaucoma undergoing cataract surgery.METHODS:An investigator-initiated,single-center,prospective,interventional,noncomparative study conducted in Montreal,Canada.The study enrolled 31 patients(55 eyes)with OHT or mild glaucoma who received a non-diffractive EDOF IOL(Acrysof IQ Vivity).Participants underwent sequential cataract surgery with the Vivity IOL.Follow-up evaluations occurred at 1d,1,and 3mo postoperatively,assessing uncorrected distance,intermediate,and near visual acuity.Questionnaires(QUVID:Questionnaire for visual disturbances and IOLSAT:Intraocular lens satisfaction)were administered pre and post-operatively to measure visual disturbances and spectacle independence in various lighting.Safety parameters included intraocular pressure(IOP),glaucoma medications,spherical equivalence,mean deviation and pattern standard deviation or square root of lost variance on Octopus visual field.RESULTS:At 1 and 3mo postoperatively,significant improvements were observed in uncorrected distance and intermediate visual acuity.Spectacle independence was enhanced for distance and intermediate vision,especially in bright light settings.Spectacle-free intermediate vision was improved even in dim lighting.Visual disturbances,particularly glare symptoms,were reduced,and there was a notable decrease in IOP and glaucoma medication burden at 3mo.There was more hazy vision postoperatively with no impact on visual acuity and visual satisfaction.CONCLUSION:The non-diffractive EDOF lens improves distance and intermediate spectacle-free visual function in patients with OHT and well-controlled glaucoma.The findings highlight significant improvements in visual acuity,reduced glare,enhanced spectacle independence,and improved visual performance in different lighting conditions.展开更多
Concentrated solar thermal power generation has been experimentally tested in advanced countries for a period of time.This paper demonstrates how this technology can be improved by using water molecules as a medium to...Concentrated solar thermal power generation has been experimentally tested in advanced countries for a period of time.This paper demonstrates how this technology can be improved by using water molecules as a medium to drive traditional generator sets for energy conversion,thereby simultaneously improving the energy conversion rate.Additionally,a novel contribution is made by incorporating a magic number 4 to enhance the focusing efficiency of Fresnel lenses,which drives improvements in power generation output and QE(Quantum Efficiency).展开更多
基金Supported by the Zhejiang Medical Health Science and Technology Project(No.2021KY217)the Basic Public Welfare Research Project of Wenzhou Municipal Science and Technology Bureau(No.2024Y1221).
文摘AIM:To evaluate and compare alterations in the effective lens position(ELP)and refractive outcomes among three distinct intraocular lens(IOL)types.METHODS:Patients with cataracts were enrolled and allocated to 3 groups:Group A(implanted with the SN6CWS),Group B(implanted with the MI60),and Group C(implanted with the Aspira-aA).ELP measurements were obtained with swept-source optical coherence tomography(SS-OCT)at 1d,1wk,1mo,and 3mo postoperatively.Subjective refraction assessments were conducted at 1wk,1mo,and 3mo following surgery.RESULTS:The study included 189 eyes of 150 cataract patients(66 males).There were 77 eyes in Group A,55 eyes in Group B,and 57 eyes in Group C.The root mean square of the ELP(ELPRMS)within the initial 3mo was significantly lower for Group A than for Groups B and C.Refractive changes within Group A were not significant across the time points of 1wk,1mo,and 3mo.Conversely,both Group B and Group C demonstrated statistically significant shifts toward hyperopia from 1wk to 3mo postsurgery.CONCLUSION:Among the three IOLs examined,the SN6CWS IOL showes the greatest stability during the first 3mo postoperatively.Between 1wk and 3mo after surgery,notable hyperopic shifts are evident in eyes implanted with the MI60 and Aspira-aA IOLs,whereas refractive outcomes remain relatively constant in eyes implanted with SN6CWS IOLs.
文摘AIM:To investigate age-related differences in the irislens angle(ILA)among patients with age-related cortical cataracts and elucidate the impact of age on lens stability.METHODS:A prospective observational study was conducted on patients with age-related cortical cataracts scheduled for phacoemulsification surgery.Preoperative ultrasound biomicroscopy(UBM)images were collected and analyzed.Initially,patients were stratified into two age groups:<60y and≥60y,with no significant intergroup differences in sex or eye laterality.For further analysis,participants were subdivided into three age strata:<60y,60-75y,and>75y.The ILA was measured in four quadrants(superior,inferior,nasal,and temporal).Intergroup differences in ILA were compared,and correlations between age and ILA parameters were analyzed using statistical methods.RESULTS:The sample data were categorized into three groups according to age,<60y(113 patients;55.8%female),60–75y(245 patients;61.0%female),and>75y(70 patients;50.2%female).The superior quadrant ILA increased progressively with age stratification(P=0.02),and the maximum ILA difference(ΔILA)was significantly higher in patients over 75y(P<0.01).Simple linear regression analysis demonstrated a positive correlation between age and ILA in the superior(Y=7.487+0.096X,R=0.191,P<0.001)and temporal(Y=10.254+0.052X,R=0.104,P=0.032)quadrants.Additionally,the mean ILA across all quadrants(ILAmean)andΔILA were positively correlated with age(ILAmean:Y=9.721+0.055X,R=0.138,P=0.004;ΔILA:Y=3.267+0.044X,R=0.006,P<0.05).CONCLUSION:In patients with age-related cortical cataracts,ILA increases with age,particularly in the superior and temporal quadrants,suggesting that advanced age is associated with greater lens deviation and decreased lens stability.UBM imaging can effectively evaluate the status of the zonule and lens stability,providing crucial evidence for personalized surgical planning based on patients’age.
文摘MXene-based smart contact lenses demonstrate a cutting-edge advancement in wearable ophthalmic technology,combining real-time biosensing,therapeutic capabilities,and user comfort in a single platform.These devices take the advantage of the exceptional electrical conductivity,mechanical flexibility,and biocompatibility of two-dimensional MXenes to enable noninvasive,tear-based monitoring of key physiological markers such as intraocular pressure and glucose levels.Recent developments focus on the integration of transparent MXene films into the conventional lens materials,allowing multifunctional performance including photothermal therapy,antimicrobial and anti-inflammation protection,and dehydration resistance.These innovations offer promising strategies for ocular disease management and eye protection.In addition to their multifunctionality,improvements in MXene synthesis and device engineering have enhanced the stability,transparency,and wearability of these lenses.Despite these advances,challenges remain in long-term biostability,scalable production,and integration with wireless communication systems.This review summarizes the current progress,key challenges,and future directions of MXene-based smart contact lenses,highlighting their transformative potential in next-generation digital healthcare and ophthalmic care.
基金Supported by the National Natural Science Foundation of China(No.81900841)the Guangzhou Major Difficult and Rare Diseases Project(No.2024MDRD05)+2 种基金the Guangdong Basic and Applied Basic Research Foundation(No.2021A1515011673No.2022A1515011181)the Guangzhou Basic Research Program,City&University(Institute)Joint Funding Project(No.SL2023A03J00514).
文摘AIM:To investigate the characteristics and associated factors of intraocular lens(IOL)tilt and decentration after transscleral suture-fixated IOL surgery in congenital ectopia lentis(CEL).METHODS:CEL patients undergoing transscleral suture-fixated IOL surgery were divided into two groups based on implanted IOL type(three-piece IOL or one-piece IOL).The IOL tilt and decentration at 3-month and 1-year postoperative were measured.Multivariate regression analyses were performed to identify the associated factors of IOL tilt and decentration as well as longitudinal changes.RESULTS:The 61 CEL patients(mean age 9.07±5.05y)in three-piece IOL(M/F:14/7)group had a greater tilt than those with one-piece IOL(M/F:28/12)group both at 3-month postoperative(horizontal:P=0.024;vertical:P=0.048)and 1-year postoperative(horizontal:P=0.011;vertical:P=0.001).Three-piece IOL group had a greater longitudinal change between 3-month postoperative to 1-year postoperative in IOL tilt(horizontal:P=0.028;vertical:P=0.026)and a greater longitudinal change in horizontal IOL decentration than one-piece IOL group(P<0.05).The longer axial length(AL)was associated with the longitudinal changes in IOL tilt(P=0.039),while the three-piece IOL was associated with the longitudinal changes in horizontal IOL decentration 1-year postoperatively(P=0.011).CONCLUSION:IOL tilt is greater in the three-piece IOL group than that in the one-piece IOL group 1-year postoperatively.The three-piece IOL is associated with greater longitudinal changes of IOL decentration,while longer AL is associated with longitudinal changes of IOL tilt.For CEL patients,more stable IOL type should be selected and patients with longer AL warrant closer monitoring.
基金Supported by the National Natural Science Foundation of China(No.82171095)the Project of Shanghai Science and Technology(No.23XD1400500)the Research Fund of Sichuan Academy of Medical Sciences and Sichuan Provincial People’s Hospital(No.24QNPY049).
文摘AIM:To evaluate the differences and consistency of vault measurements obtained by Scheimpflug tomography(Pentacam),anterior segment optical coherence tomography(AS-OCT,CASIA II),and ultrasound biomicroscopy(UBM)following implantable collamer lens(ICL)V4c implantation.METHODS:Vault measurements were acquired using three modalities:Pentacam,CASIA II AS-OCT,and UBM.Repeated-measures analysis of variance was used to compare the vault values obtained by the three devices.The correlation and consistency of measurements among the three instruments were assessed using the Pearson correlation coefficient,intraclass correlation coefficient(ICC),and Bland-Altman plots.RESULTS:This retrospective study enrolled 210 myopic eyes of 210 patients(158 women and 52 men)who underwent ICL implantation:108 eyes had a myopic ICL V4c implanted,and 102 eyes had a toric ICL V4c implanted.The mean vault values measured by Pentacam,CASIA II,and UBM were 452.64±204.20μm,538.57±203.54μm,and 560.95±227.54μm,respectively,with statistically significant differences among the three groups(P<0.05).Pearson correlation analysis showed strong positive correlations between vault values measured by different instruments(all P<0.001).ICC results indicated good consistency among the three measurement modalities(all P<0.001).Stratified analysis revealed that when the vault value was≤250μm,the correlation and consistency of measurements across the three instruments were lower than those in the medium and high vault subgroups.CONCLUSION:Vault values measured by Pentacam are lower than those obtained by CASIA II and UBM,with UBM yielding the highest mean vault values.Measurements from the three instruments are not interchangeable but can serve as mutual references due to their significant correlation and good overall consistency.Pentacam and CASIA II demonstrate the highest consistency in vault measurement.Notably,when the vault value is≤250μm,the consistency between Pentacam and the other two instruments decreases significantly.
文摘AIM:To investigate the long-term outcomes in acute primary angle closure(APAC)patients treated with lens extraction(LE)surgery and to identify risk factors for glaucomatous optic neuropathy(GON).METHODS:In this longitudinal observational study,detailed medical histories of APAC patients and comprehensive ophthalmic examinations at final followup were collected.Logistic regression analysis was performed to identify predictors of blindness.Univariate and multivariate linear regression analyses were conducted to determine risk factors associated with visual outcomes.RESULTS:This study included 39 affected eyes of 31 subjects(26 females)with an average age of 74.1±8.0y.At 6.7±4.2y after APAC attack,2(5.7%)eyes had bestcorrected visual acuity(VA)worse than 3/60.Advanced glaucomatous visual field loss was observed in 15(39.5%)affected eyes and 5(25.0%)fellow eyes.Nine affected eyes(23.7%)had GON,and 11(28.9%)were blind.Six(15.4%)affected eyes and 2(9.1%)fellow eyes had suspicious progression.A significantly higher blindness rate in factory workers compared to office workers.Logistic regression identified that worse VA at attack(OR 10.568,95%CI 1.288-86.695;P=0.028)and worse early postoperative VA(OR 13.214,95%CI 1.157-150.881;P=0.038)were risk factors for blindness.Multivariate regression showed that longer duration of elevated intraocular pressure(P=0.004)and worse early postoperative VA(P=0.009)were associated with worse visual outcomes.CONCLUSION:Despite LE surgery,some APAC patients experience continued visual function deterioration.Lifelong monitoring is necessary.Target pressure and progression rates should be re-evaluated during follow-up.
基金supported by the National Natural Science Foundation of China(Grant No.52178376)National Key R&D Program of China(Grant No.2022YFB2603301)Science and Technology Research and Development Program of China Railway Group Limited(Grant No.2022-ZD-13).
文摘Ice lens initiation is the core issue in understanding the dynamic process of frost heave.However,there are still limitations to find an adequate criterion for describing the formation of ice lens.A series of one-dimensional freezing tests is designed using the particle image velocimetry(PIV)method to monitor the frost heave and ice lens formation.The results show that the conventional parameters,such as displacement and velocity,cannot be used to track the ice lens formation,while the strain can be employed to detect the ice lens formation and investigate the freezing change patterns.This study proposes strain as a new criterion for assessing ice lens initiation,applicable across various soil types and freezing conditions(constant freezing and ramped freezing).The strain change in the region where the ice lens forms is the largest during the freezing process.Additionally,strain curves at the top of the soil samples can reveal different freezing patterns and distinguish the first and second frost heave stages.This newly developed technology enables continuous,non-destructive monitoring of ice lens initiation across diverse conditions and soil types,enhancing data visualization and three-dimensional modeling of freezing parameters while improving traditional methods by directly measuring velocity and strain in frost heave investigations.The study is expected to enhance the research of ice lens criterion and provide a new perspective for monitoring the freezing process.
基金supported by the National Key R&D Program of China(Grant No.2021YFB3802303)the National Natural Science Foundation of China(Grant Nos.12302493 and 12525211).
文摘The manipulation of intense shock waves to either attenuate or enhance damage has long been a key goal in the domain of impact dynamics.Effective methods for such manipulation,however,remain elusive owing to the wide spectrum and irreversible destructive nature of intense shock waves.This work proposes a novel approach for actively controlling intense shock waves in solids,inspired by the principles of optical and explosive lenses.Specifically,by designing a shock wave convex lens composed of a low-shock-impedance material embedded in a high-shock-impedance matrix,we prove the feasibility of transforming a planar shock into a spherically converging shock.This is based on oblique shock theory,according to which shock waves pass through an oblique interface and then undergo deflection.Both experimental and simulation results demonstrate that,as expected,the obtained local spherical shock wave has a wavefront that is nearly perfectly spherical and uniform in pressure.Thus,this work proves the possibility of generating spherical shock waves using plate-impact experiments and highlights the potential of further exploration of the manipulation of shock waves in solids.It also contributes an innovative perspective for both armor penetration technologies and shock wave mitigation strategies.
基金National Natural Science Foundation of China(62125504,62405288)Natural Science Foundation of Zhejiang Province(LQN25F050005)National Key Research and Development Program of China(2021YFF0502700)。
文摘Flat lenses,including metalenses and diffractive lenses,have attracted considerable attention for enabling miniaturized optical systems.However,achieving large-scale flat lenses with both a large numerical aperture(NA)and high achromatic performance remains a significant challenge.In this work,we propose a structural height optimization method named focal phasor matching to achieve high-performance designs for large apertures.
基金Supported by the National Key Research and Development Program(No.2019YFC1710200)the Shandong Province Pharmaceutical Technology Development Project(No.202107020970).
文摘Dear Editor,The latest Visian implantable collamer lens(ICL)with a central port design(Aquaport;model V4c)obviates the necessity for preoperative laser iridotomy or intraoperative iridectomy by allowing the free flow of the aqueous humor between the sides of the intraocular lens.The design of Aquaport can also eliminate the complications associated with iridotomy and iridectomy.Therefore,the V4c ICL has the potential to significantly reduce the risk of pupillary block compared to its predecessors.
基金supported by the 2022 Fujian Provincial Young and Middle-aged Teacher Education and Research Project(Science and Technology)(No.JAT220468)the Xiamen Natural Science Foundation(No.3502Z20227334).
文摘At present,the naked-eye three-dimensional(3D)display technology still has some drawbacks,such as low brightness uniformity,high crosstalk,low light efficiency,short viewing distance,and the manufacturing is difficulty.Based on the principle of naked-eye 3D display and the Fresnel optical theory,this paper designs a Fresnel lens array and the star-shaped liquid crystal display(LCD)switch of unit LCD screen to achieve low-crosstalk and high brightness uniformity for the autostereoscopic 3D display.The unit parameters of a 139.7 cm 4K model autostereoscopic 3D displayer are provided and they are optimized by the TracePro software.The results show that when the pitch of the Fresnel lens on the exit surface is 0.304 mm,the width of each serration of Fresnel lens is 0.0234 mm,the length of the Fresnel lens is 2.87 mm,and the center height of star-shaped LCD switch is 0.030 mm,the center length is 0.040 mm,the width of star-shaped LCD switch is 0.050 mm,and the image crosstalk is less than 2%when the viewing distance is 2.50 m.The problem on the brightness of the image in different positions is improved.
文摘AIM:To assess whether the implantation of a posterior chamber phakic intraocular lens produces changes in optical coherence tomography(OCT)measurements of macular thickness(MT)and two parameters that define the structure of the optic nerve,the peripapillary nerve fiber layer(RNFL)and the Bruch’s membrane opening-minimum rim width(BMO-MRW).METHODS:This nonrandomized prospective pre-post study included 86 eyes of 48 patients(age,20-47y;axial length:23.10-28.95 mm)scheduled for myopia or myopic astigmatism correction with implantation of the implantable collamer lens(ICL).Eyes with glaucoma or any other ocular disease that could alter OCT results were excluded.RNFL,BMO-MRW and MT were measured preoperatively,and at 1 and 6mo after surgery using spectral-domain OCT.Changes between preoperative and postoperative values were evaluated.RESULTS:There was a significant increase in BMOMRW at 1mo(mean change:3.48±15.07μm,P=0.041).No significant changes were found during the rest of followup(1-6mo postop.,P=0.623).There was also a significant increase in RNFL thickness at 1mo af ter surger y(1.45±2.18μm,P<0.001),but with a significant reduction from 1 to 6mo postoperatively(P=0.002).Regarding MT,it increased significantly at 1mo(2.46±3.76μm,P<0.001),with a significant decrease afterwards(P=0.048).Measurements of the three parameters at 6mo were slightly superior to preoperative values(P<0.01).CONCLUSION:Minimal changes are induced in BMOMRW,RNFL and MT after ICL implantation in healthy eyes,confirming the safety of the surgical procedure regarding the structure of the optic nerve head and the macula,and indicating that this phakic intraocular lens seems to have a slight impact on OCT measurements.
基金supported by the National Natural Science Foundation of China(82371089).
文摘Objective:To evaluate the performance of orthokeratology(ortho-k)lens reordering using software-designed system,so as to determine the feasibility of ortho-k lens reordering without discontinuing lens wear.Methods:This study is a retrospective analysis of data of ortho-k lens wearers who had a history of short-term discontinuation of lens wear.A total of 94 individuals aged over 8 years with spherical equivalent refraction ranging from-0.50 to-6.50 diopters were included.The corneal topography data at baseline(before ortho-k)and after lens wear discontinuation(cessation of ortho-k treatment)were imported separately into the lens-design software,along with corresponding refraction data.Subsequently,corneal and lens parameters were generated and compared.Intraclass correlation coefficients(ICC)were calculated,and Bland and Altman analyses were conducted.Results:All 94 children were involved in the retrospective analysis.Compared with baseline data,there was a high level of consistency between Rwo(without discontinuation)and Rwith(with discontinuation),with an ICC of 0.96(P<0.001).Furthermore,the comparison of lens parameters generated by the Easyfit software between baseline and after short-term discontinuation showed a high degree of consistency,with all of the ICC values exceeding 0.90.Similar results were obtained using the WAVE software,as both ICC values and Bland-Altman plots demonstrated a high level of consistency in lens parameters between two conditions(nearly all data points fell within the 95%LoAs).Conclusions:It is feasible to directly reorder new ortho-k lenses using software fitting approaches.However,further investigations are necessary to validate their practicability in a clinical setting.
文摘As cataract surgery progresses from “restoration of sight” to “refractive correction”, precise prediction of intraocular lens (IOL) power is critical for enhancing postoperative visual quality in patients. IOL power calculation methods have evolved and innovated throughout time, from early theoretical and regression formulas to nonlinear formulas for estimating effective lens position (ELP), multivariable formulas, and innovative formulas that use optical principles and AI-based online formulas. This paper thoroughly discusses the development and iteration of traditional IOL calculation formulas, the emergence of new IOL calculation formulas, and the selection of IOL calculation formulas for different patients in the era of refractive cataract surgery, serving as a reference for “personalized” IOL implantation in clinical practice.
文摘Background:The Akreos®AO60 intraocular lens(IOL)has been employed for scleral fixation in eyes without capsular support,although surgical complications,including IOL opacification,have been reported.This study aims to evaluate the outcomes and complications associated with scleral fixation of the Akreos®AO60 IOL in vitrectomized eyes,with a particular focus on IOL opacification.Methods:Electronic medical records of consecutive eyes that underwent scleral-fixation of the Akreos®AO60 lens using Gore-tex®sutures from 2017 to 2022 were reviewed.The following parameters were collected:age,sex,laterality,past ocular/medical history,surgical indication,pre-operative visual acuity(VA)and intraocular pressure(IOP),surgical procedure,and post-operative VA and IOP.The types of complications,onset,management,and outcomes were also documented.Descriptive statistics,Wilcoxon signed-rank test,and Fisher’s exact test were employed for statistical analysis.Results:Eighty-nine eyes of 86 patients aged 31-100 years were included.The most common surgical indication was non-traumatic IOL displacement.Retinal tears and localized choroidal hemorrhage were found intraoperatively in 7.9%and 1.1%,respectively.The most common post-operative complications were vitreous hemorrhage(13.5%),corneal edema(12.4%),ocular hypotony(11.2%),and IOL opacification(11.2%).IOL opacification was associated with intra-/post-operative exposure to air/gas[odds ratio(OR):12.24;95%confidence interval(CI),1.46-103.0;P=0.006].Mean logarithm of the minimum angle of resolution(logMAR)best-reported VA(BRVA)improved from 1.22±0.77 pre-operatively to 0.56±0.67 on latest follow-up(P<0.001).Conclusions:The majority of the complications from scleral-fixation of the Akreos®AO60 lens in vitrectomized eyes were mild and transient;however,a proportion required surgical intervention.A significant risk for opacification was found in IOLs exposed to air/gas,although VA was often maintained.
基金supported by the National Natural Science Foundation of China under Grants Nos.12475056,12347177,and 12247101,the 111 Project under Grant No.B20063Lanzhou City's scientific research funding subsidy to Lanzhou Universitythe Gansu Province Major Scientific and Technological Special Project。
文摘We study the lensing phenomena of the strong gravity regime of five-dimensional charged,equally rotating black holes with a cosmological constant,familiarly known as the Cvetic–Lu–Pope(CLP)black holes.These black holes are characterized by three observable parameters,the mass M,the charge Q and the angular momentum J,in addition to the cosmological constant.We investigate the strong gravitational lensing observables,mainly the photon sphere radius,the minimum impact parameter,the deflection angle,the angular size,and the magnification of the relativistic images.We model the M87 and SgrA*for these observables.We also focus on the relativistic time delay effect in the strong-field regime of gravity and the impact of the observable on it.The analytical expressions for the observables of the relativistic images with vanishing angular momentum(j=0)are discussed in some detail.We shed a light on the gravitational time delay effect by incorporating the lensing observables.The gravitational time delay has a direct consequence on the photon sphere radius and hence on the quasinormal modes.
文摘AIM:To compare the clinical outcomes of extended depth-of-focus intraocular lenses(EDOF IOLs)using either micromonovision implantation or mixed implantation of EDOF and diffractive bifocal IOLs.METHODS:This retrospective clinical trial included 130 patients(260 eyes),who were divided into two groups.Group RR comprised 70 patients(140 eyes)bilaterally implanted with ZXR00 IOLs(Tecnis ZXR00,where one target was-0.5 D to-0.75 D and the other was 0 to-0.25 D).Group RM comprised 60 patients(120 eyes)unilaterally implanted with both ZXR00 and ZMB00 IOLs(Tecnis ZMB00,0 to-0.25 D).Postoperative outcomes were compared after 3 mo,including visual acuity,defocus curves,stereoacuity,modulation transfer functions(MTFs),higher-order aberrations,and Visual Function-14(VF-14)questionnaire responses.RESULTS:Group RR had superior bilateral intermediate vision,while the group RM had superior bilateral near vision(both P<0.05).Group RM also exhibited superior MTFs and reduced higher-order aberrations(both P<0.05).Stereoacuity and VF-14 questionnaire results showed no statistically significant difference between groups(P>0.05).CONCLUSION:The implantation of micromonovision has significantly improved near vision.IOLs and their collocation can be customized according to individual patient needs to achieve precise treatment and provide cataract patients with high-quality vision.
文摘AIM:To evaluate the visual and refractive outcomes in cases after sutured scleral fixation of existing subluxated or dislocated acrylic one-piece intraocular lenses(IOLs).METHODS:This study retrospectively enrolled a consecutive series of patients who underwent a surgery of sutured existing subluxated or dislocated IOLs from October 2018 to June 2020.All patients underwent comprehensive preoperative and postoperative ophthalmologic examination,and data were collected including age,sex,surgical indications,best-corrected visual acuity,refractive error,intraocular pressure.Presence of intraoperative and postoperative surgical complications was documented.RESULTS:A total of 20 consecutive cases were enrolled for analysis with mean final follow-up period 9.8±5.3mo.Visual acuity improved from a mean of 0.35(0.46±0.32 logMAR)preoperatively to 0.61(0.21±0.18 logMAR)at the 3-month follow-up(P=0.002).The mean amount of preoperative keratometric astigmatism and total postoperative refractive astigmatism was-1.24±0.80 diopters(D)and-1.42±0.97 D,respectively.There was no statistically significant difference between preoperative and postoperative astigmatism(P=0.156).The mean IOL-induced astigmatism was-0.23±0.53 D.The mean spherical equivalent at the 3-month follow-up was-0.1±0.94 D.No major complications were noted during the follow-up period.CONCLUSION:Surgical techniques using sutured scleral fixation of existing subluxated or dislocated acrylic one-piece IOLs result in favorable visual and refractive outcomes without major complications.
文摘AIM:To assess visual outcomes and satisfaction of a non-diffractive extended depth of focus(EDOF)intraocular lens(IOL)in individuals with ocular hypertension(OHT)and well-controlled mild glaucoma undergoing cataract surgery.METHODS:An investigator-initiated,single-center,prospective,interventional,noncomparative study conducted in Montreal,Canada.The study enrolled 31 patients(55 eyes)with OHT or mild glaucoma who received a non-diffractive EDOF IOL(Acrysof IQ Vivity).Participants underwent sequential cataract surgery with the Vivity IOL.Follow-up evaluations occurred at 1d,1,and 3mo postoperatively,assessing uncorrected distance,intermediate,and near visual acuity.Questionnaires(QUVID:Questionnaire for visual disturbances and IOLSAT:Intraocular lens satisfaction)were administered pre and post-operatively to measure visual disturbances and spectacle independence in various lighting.Safety parameters included intraocular pressure(IOP),glaucoma medications,spherical equivalence,mean deviation and pattern standard deviation or square root of lost variance on Octopus visual field.RESULTS:At 1 and 3mo postoperatively,significant improvements were observed in uncorrected distance and intermediate visual acuity.Spectacle independence was enhanced for distance and intermediate vision,especially in bright light settings.Spectacle-free intermediate vision was improved even in dim lighting.Visual disturbances,particularly glare symptoms,were reduced,and there was a notable decrease in IOP and glaucoma medication burden at 3mo.There was more hazy vision postoperatively with no impact on visual acuity and visual satisfaction.CONCLUSION:The non-diffractive EDOF lens improves distance and intermediate spectacle-free visual function in patients with OHT and well-controlled glaucoma.The findings highlight significant improvements in visual acuity,reduced glare,enhanced spectacle independence,and improved visual performance in different lighting conditions.
文摘Concentrated solar thermal power generation has been experimentally tested in advanced countries for a period of time.This paper demonstrates how this technology can be improved by using water molecules as a medium to drive traditional generator sets for energy conversion,thereby simultaneously improving the energy conversion rate.Additionally,a novel contribution is made by incorporating a magic number 4 to enhance the focusing efficiency of Fresnel lenses,which drives improvements in power generation output and QE(Quantum Efficiency).