期刊文献+
共找到3,220篇文章
< 1 2 161 >
每页显示 20 50 100
Postoperative effective lens position and refraction changes with three different types of intraocular lens
1
作者 Xi-Xia Ding Lin-Feng Xiang +5 位作者 Wen-Tao Tong Dan-Dan Wang Hong-FangZhang Ping-Jun Chang Fu-Man Yang Yun-E Zhao 《International Journal of Ophthalmology(English edition)》 2026年第2期260-265,共6页
AIM:To evaluate and compare alterations in the effective lens position(ELP)and refractive outcomes among three distinct intraocular lens(IOL)types.METHODS:Patients with cataracts were enrolled and allocated to 3 group... AIM:To evaluate and compare alterations in the effective lens position(ELP)and refractive outcomes among three distinct intraocular lens(IOL)types.METHODS:Patients with cataracts were enrolled and allocated to 3 groups:Group A(implanted with the SN6CWS),Group B(implanted with the MI60),and Group C(implanted with the Aspira-aA).ELP measurements were obtained with swept-source optical coherence tomography(SS-OCT)at 1d,1wk,1mo,and 3mo postoperatively.Subjective refraction assessments were conducted at 1wk,1mo,and 3mo following surgery.RESULTS:The study included 189 eyes of 150 cataract patients(66 males).There were 77 eyes in Group A,55 eyes in Group B,and 57 eyes in Group C.The root mean square of the ELP(ELPRMS)within the initial 3mo was significantly lower for Group A than for Groups B and C.Refractive changes within Group A were not significant across the time points of 1wk,1mo,and 3mo.Conversely,both Group B and Group C demonstrated statistically significant shifts toward hyperopia from 1wk to 3mo postsurgery.CONCLUSION:Among the three IOLs examined,the SN6CWS IOL showes the greatest stability during the first 3mo postoperatively.Between 1wk and 3mo after surgery,notable hyperopic shifts are evident in eyes implanted with the MI60 and Aspira-aA IOLs,whereas refractive outcomes remain relatively constant in eyes implanted with SN6CWS IOLs. 展开更多
关键词 effective lens position REFRACTION intraocular lens swept-source optical coherence tomography
原文传递
Ultrasound biomicroscopy analysis of age-related trends in lens stability in cortical cataracts
2
作者 Jia-Jun Chen Ling Wang +3 位作者 Sha-Sha Xue Zhi-Ying Yu Yun-Xiao Wang Feng-Lei Wang 《International Journal of Ophthalmology(English edition)》 2026年第2期252-259,共8页
AIM:To investigate age-related differences in the irislens angle(ILA)among patients with age-related cortical cataracts and elucidate the impact of age on lens stability.METHODS:A prospective observational study was c... AIM:To investigate age-related differences in the irislens angle(ILA)among patients with age-related cortical cataracts and elucidate the impact of age on lens stability.METHODS:A prospective observational study was conducted on patients with age-related cortical cataracts scheduled for phacoemulsification surgery.Preoperative ultrasound biomicroscopy(UBM)images were collected and analyzed.Initially,patients were stratified into two age groups:<60y and≥60y,with no significant intergroup differences in sex or eye laterality.For further analysis,participants were subdivided into three age strata:<60y,60-75y,and>75y.The ILA was measured in four quadrants(superior,inferior,nasal,and temporal).Intergroup differences in ILA were compared,and correlations between age and ILA parameters were analyzed using statistical methods.RESULTS:The sample data were categorized into three groups according to age,<60y(113 patients;55.8%female),60–75y(245 patients;61.0%female),and>75y(70 patients;50.2%female).The superior quadrant ILA increased progressively with age stratification(P=0.02),and the maximum ILA difference(ΔILA)was significantly higher in patients over 75y(P<0.01).Simple linear regression analysis demonstrated a positive correlation between age and ILA in the superior(Y=7.487+0.096X,R=0.191,P<0.001)and temporal(Y=10.254+0.052X,R=0.104,P=0.032)quadrants.Additionally,the mean ILA across all quadrants(ILAmean)andΔILA were positively correlated with age(ILAmean:Y=9.721+0.055X,R=0.138,P=0.004;ΔILA:Y=3.267+0.044X,R=0.006,P<0.05).CONCLUSION:In patients with age-related cortical cataracts,ILA increases with age,particularly in the superior and temporal quadrants,suggesting that advanced age is associated with greater lens deviation and decreased lens stability.UBM imaging can effectively evaluate the status of the zonule and lens stability,providing crucial evidence for personalized surgical planning based on patients’age. 展开更多
关键词 iris-lens angle age-related cortical cataract lens stability ultrasound biomicroscopy PHACOEMULSIFICATION surgical planning
原文传递
MXene-Based Wearable Contact Lenses: Integrating Smart Technology into Vision Care
3
作者 Arezoo Khosravi Atefeh Zarepour +1 位作者 Ali Zarrabi Siavash Iravani 《Nano-Micro Letters》 2026年第1期490-508,共19页
MXene-based smart contact lenses demonstrate a cutting-edge advancement in wearable ophthalmic technology,combining real-time biosensing,therapeutic capabilities,and user comfort in a single platform.These devices tak... MXene-based smart contact lenses demonstrate a cutting-edge advancement in wearable ophthalmic technology,combining real-time biosensing,therapeutic capabilities,and user comfort in a single platform.These devices take the advantage of the exceptional electrical conductivity,mechanical flexibility,and biocompatibility of two-dimensional MXenes to enable noninvasive,tear-based monitoring of key physiological markers such as intraocular pressure and glucose levels.Recent developments focus on the integration of transparent MXene films into the conventional lens materials,allowing multifunctional performance including photothermal therapy,antimicrobial and anti-inflammation protection,and dehydration resistance.These innovations offer promising strategies for ocular disease management and eye protection.In addition to their multifunctionality,improvements in MXene synthesis and device engineering have enhanced the stability,transparency,and wearability of these lenses.Despite these advances,challenges remain in long-term biostability,scalable production,and integration with wireless communication systems.This review summarizes the current progress,key challenges,and future directions of MXene-based smart contact lenses,highlighting their transformative potential in next-generation digital healthcare and ophthalmic care. 展开更多
关键词 MXenes Wearable contact lenses Intraocular lenses Drug delivery Wearable electronics
在线阅读 下载PDF
Intraocular lens tilt and decentration in congenital ectopia lentis:baseline characteristics and first-year report
4
作者 Hui-Wen Ye Xin-Xin Liu +4 位作者 Zhen-Zhen Liu Yi-Yuan Ma Xin-Yu Zhang Dan-Ying Zheng Guang-Ming Jin 《International Journal of Ophthalmology(English edition)》 2026年第3期468-474,共7页
AIM:To investigate the characteristics and associated factors of intraocular lens(IOL)tilt and decentration after transscleral suture-fixated IOL surgery in congenital ectopia lentis(CEL).METHODS:CEL patients undergoi... AIM:To investigate the characteristics and associated factors of intraocular lens(IOL)tilt and decentration after transscleral suture-fixated IOL surgery in congenital ectopia lentis(CEL).METHODS:CEL patients undergoing transscleral suture-fixated IOL surgery were divided into two groups based on implanted IOL type(three-piece IOL or one-piece IOL).The IOL tilt and decentration at 3-month and 1-year postoperative were measured.Multivariate regression analyses were performed to identify the associated factors of IOL tilt and decentration as well as longitudinal changes.RESULTS:The 61 CEL patients(mean age 9.07±5.05y)in three-piece IOL(M/F:14/7)group had a greater tilt than those with one-piece IOL(M/F:28/12)group both at 3-month postoperative(horizontal:P=0.024;vertical:P=0.048)and 1-year postoperative(horizontal:P=0.011;vertical:P=0.001).Three-piece IOL group had a greater longitudinal change between 3-month postoperative to 1-year postoperative in IOL tilt(horizontal:P=0.028;vertical:P=0.026)and a greater longitudinal change in horizontal IOL decentration than one-piece IOL group(P<0.05).The longer axial length(AL)was associated with the longitudinal changes in IOL tilt(P=0.039),while the three-piece IOL was associated with the longitudinal changes in horizontal IOL decentration 1-year postoperatively(P=0.011).CONCLUSION:IOL tilt is greater in the three-piece IOL group than that in the one-piece IOL group 1-year postoperatively.The three-piece IOL is associated with greater longitudinal changes of IOL decentration,while longer AL is associated with longitudinal changes of IOL tilt.For CEL patients,more stable IOL type should be selected and patients with longer AL warrant closer monitoring. 展开更多
关键词 ectopia lentis intraocular lens tilt intraocular lens decentration
原文传递
Comparison of three different instruments for vault measurements after implantable collamer lens implantation
5
作者 Bo-Liang Li Ming-Rui Cheng +6 位作者 Wei-Teng Chang Ya-Di Lei Guang-Han Xu Ming-Wei Li Zhi-Wei Mao Xun Chen Xiao-Ying Wang 《International Journal of Ophthalmology(English edition)》 2026年第3期475-482,共8页
AIM:To evaluate the differences and consistency of vault measurements obtained by Scheimpflug tomography(Pentacam),anterior segment optical coherence tomography(AS-OCT,CASIA II),and ultrasound biomicroscopy(UBM)follow... AIM:To evaluate the differences and consistency of vault measurements obtained by Scheimpflug tomography(Pentacam),anterior segment optical coherence tomography(AS-OCT,CASIA II),and ultrasound biomicroscopy(UBM)following implantable collamer lens(ICL)V4c implantation.METHODS:Vault measurements were acquired using three modalities:Pentacam,CASIA II AS-OCT,and UBM.Repeated-measures analysis of variance was used to compare the vault values obtained by the three devices.The correlation and consistency of measurements among the three instruments were assessed using the Pearson correlation coefficient,intraclass correlation coefficient(ICC),and Bland-Altman plots.RESULTS:This retrospective study enrolled 210 myopic eyes of 210 patients(158 women and 52 men)who underwent ICL implantation:108 eyes had a myopic ICL V4c implanted,and 102 eyes had a toric ICL V4c implanted.The mean vault values measured by Pentacam,CASIA II,and UBM were 452.64±204.20μm,538.57±203.54μm,and 560.95±227.54μm,respectively,with statistically significant differences among the three groups(P<0.05).Pearson correlation analysis showed strong positive correlations between vault values measured by different instruments(all P<0.001).ICC results indicated good consistency among the three measurement modalities(all P<0.001).Stratified analysis revealed that when the vault value was≤250μm,the correlation and consistency of measurements across the three instruments were lower than those in the medium and high vault subgroups.CONCLUSION:Vault values measured by Pentacam are lower than those obtained by CASIA II and UBM,with UBM yielding the highest mean vault values.Measurements from the three instruments are not interchangeable but can serve as mutual references due to their significant correlation and good overall consistency.Pentacam and CASIA II demonstrate the highest consistency in vault measurement.Notably,when the vault value is≤250μm,the consistency between Pentacam and the other two instruments decreases significantly. 展开更多
关键词 implantable collamer lens vault measurement scheimpflug tomography anterior segment optical coherence tomography ultrasound biomicroscopy measurement consistency
原文传递
Long-term outcomes following lens extraction surgery in acute primary angle closure
6
作者 Yi-Ning Guo Jing Ding +3 位作者 Hao-Ran Ai Xin-Zuo Zhou Xue-Min Li Chun Zhang 《International Journal of Ophthalmology(English edition)》 2026年第2期281-290,共10页
AIM:To investigate the long-term outcomes in acute primary angle closure(APAC)patients treated with lens extraction(LE)surgery and to identify risk factors for glaucomatous optic neuropathy(GON).METHODS:In this longit... AIM:To investigate the long-term outcomes in acute primary angle closure(APAC)patients treated with lens extraction(LE)surgery and to identify risk factors for glaucomatous optic neuropathy(GON).METHODS:In this longitudinal observational study,detailed medical histories of APAC patients and comprehensive ophthalmic examinations at final followup were collected.Logistic regression analysis was performed to identify predictors of blindness.Univariate and multivariate linear regression analyses were conducted to determine risk factors associated with visual outcomes.RESULTS:This study included 39 affected eyes of 31 subjects(26 females)with an average age of 74.1±8.0y.At 6.7±4.2y after APAC attack,2(5.7%)eyes had bestcorrected visual acuity(VA)worse than 3/60.Advanced glaucomatous visual field loss was observed in 15(39.5%)affected eyes and 5(25.0%)fellow eyes.Nine affected eyes(23.7%)had GON,and 11(28.9%)were blind.Six(15.4%)affected eyes and 2(9.1%)fellow eyes had suspicious progression.A significantly higher blindness rate in factory workers compared to office workers.Logistic regression identified that worse VA at attack(OR 10.568,95%CI 1.288-86.695;P=0.028)and worse early postoperative VA(OR 13.214,95%CI 1.157-150.881;P=0.038)were risk factors for blindness.Multivariate regression showed that longer duration of elevated intraocular pressure(P=0.004)and worse early postoperative VA(P=0.009)were associated with worse visual outcomes.CONCLUSION:Despite LE surgery,some APAC patients experience continued visual function deterioration.Lifelong monitoring is necessary.Target pressure and progression rates should be re-evaluated during follow-up. 展开更多
关键词 acute primary angle closure lens extraction surgery long-term follow-up visual impairment glaucomatous optic neuropathy
原文传递
Measuring ice lens initiation in soils by particle image velocimetry
7
作者 Jinfeng Li Jidong Teng +3 位作者 Haosong He Wenzhang Xu Jenisha Singh Sheng Zhang 《Journal of Rock Mechanics and Geotechnical Engineering》 2026年第1期761-771,共11页
Ice lens initiation is the core issue in understanding the dynamic process of frost heave.However,there are still limitations to find an adequate criterion for describing the formation of ice lens.A series of one-dime... Ice lens initiation is the core issue in understanding the dynamic process of frost heave.However,there are still limitations to find an adequate criterion for describing the formation of ice lens.A series of one-dimensional freezing tests is designed using the particle image velocimetry(PIV)method to monitor the frost heave and ice lens formation.The results show that the conventional parameters,such as displacement and velocity,cannot be used to track the ice lens formation,while the strain can be employed to detect the ice lens formation and investigate the freezing change patterns.This study proposes strain as a new criterion for assessing ice lens initiation,applicable across various soil types and freezing conditions(constant freezing and ramped freezing).The strain change in the region where the ice lens forms is the largest during the freezing process.Additionally,strain curves at the top of the soil samples can reveal different freezing patterns and distinguish the first and second frost heave stages.This newly developed technology enables continuous,non-destructive monitoring of ice lens initiation across diverse conditions and soil types,enhancing data visualization and three-dimensional modeling of freezing parameters while improving traditional methods by directly measuring velocity and strain in frost heave investigations.The study is expected to enhance the research of ice lens criterion and provide a new perspective for monitoring the freezing process. 展开更多
关键词 Frost heave Ice lens initiation Particle image velocimetry(PIV) STRAIN
在线阅读 下载PDF
Generation of spherically converging shock wave based on shock wave lens
8
作者 Qi-Guang He Dun Wu +3 位作者 Yuying Yu Hang Zhang Qiang Wu Jianbo Hu 《Matter and Radiation at Extremes》 2025年第6期75-85,共11页
The manipulation of intense shock waves to either attenuate or enhance damage has long been a key goal in the domain of impact dynamics.Effective methods for such manipulation,however,remain elusive owing to the wide ... The manipulation of intense shock waves to either attenuate or enhance damage has long been a key goal in the domain of impact dynamics.Effective methods for such manipulation,however,remain elusive owing to the wide spectrum and irreversible destructive nature of intense shock waves.This work proposes a novel approach for actively controlling intense shock waves in solids,inspired by the principles of optical and explosive lenses.Specifically,by designing a shock wave convex lens composed of a low-shock-impedance material embedded in a high-shock-impedance matrix,we prove the feasibility of transforming a planar shock into a spherically converging shock.This is based on oblique shock theory,according to which shock waves pass through an oblique interface and then undergo deflection.Both experimental and simulation results demonstrate that,as expected,the obtained local spherical shock wave has a wavefront that is nearly perfectly spherical and uniform in pressure.Thus,this work proves the possibility of generating spherical shock waves using plate-impact experiments and highlights the potential of further exploration of the manipulation of shock waves in solids.It also contributes an innovative perspective for both armor penetration technologies and shock wave mitigation strategies. 展开更多
关键词 designing shock wave convex lens controlling intense shock waves impact dynamicseffective optical explosive lensesspecificallyby enhance damage shock wave lens intense shock wavesthis manipulation intense shock waves
在线阅读 下载PDF
High-efficiency,large-scale,high-numerical-aperture achromatic flat lens via focal phasor matching
9
作者 YUNING YE MENGDI LUO +3 位作者 JISEN WEN DAZHAO ZHU CUIFANG KUANG XU LIU 《Photonics Research》 2025年第12期3431-3443,共13页
Flat lenses,including metalenses and diffractive lenses,have attracted considerable attention for enabling miniaturized optical systems.However,achieving large-scale flat lenses with both a large numerical aperture(NA... Flat lenses,including metalenses and diffractive lenses,have attracted considerable attention for enabling miniaturized optical systems.However,achieving large-scale flat lenses with both a large numerical aperture(NA)and high achromatic performance remains a significant challenge.In this work,we propose a structural height optimization method named focal phasor matching to achieve high-performance designs for large apertures. 展开更多
关键词 flat lensesincluding focal phasor matching diffractive lenseshave high efficiency structural height optimization method flat lenses structural height optimization miniaturized optical systemshoweverachieving
原文传递
Diagnosis and treatment of pupillary block glaucoma following implantable collamer lens surgery:a case report
10
作者 Bei-Bei Wang Ying-Ying Zou +2 位作者 Dong-Mei Liu Fang Sha Hong-Sheng Bi 《International Journal of Ophthalmology(English edition)》 2025年第6期1173-1177,共5页
Dear Editor,The latest Visian implantable collamer lens(ICL)with a central port design(Aquaport;model V4c)obviates the necessity for preoperative laser iridotomy or intraoperative iridectomy by allowing the free flow ... Dear Editor,The latest Visian implantable collamer lens(ICL)with a central port design(Aquaport;model V4c)obviates the necessity for preoperative laser iridotomy or intraoperative iridectomy by allowing the free flow of the aqueous humor between the sides of the intraocular lens.The design of Aquaport can also eliminate the complications associated with iridotomy and iridectomy.Therefore,the V4c ICL has the potential to significantly reduce the risk of pupillary block compared to its predecessors. 展开更多
关键词 implantable collamer lens surgery laser iridotomy Visian ICL visian implantable collamer lens icl diagnosis pupillary block glaucoma pupillary block aqueous humor
原文传递
Design of Fresnel lens for autostereoscopic 3D display with optimized crosstalk and brightness uniformity
11
作者 LAI Liping GAo Lizhen +1 位作者 LIU Kang XU Zhankun 《Optoelectronics Letters》 2025年第11期655-660,共6页
At present,the naked-eye three-dimensional(3D)display technology still has some drawbacks,such as low brightness uniformity,high crosstalk,low light efficiency,short viewing distance,and the manufacturing is difficult... At present,the naked-eye three-dimensional(3D)display technology still has some drawbacks,such as low brightness uniformity,high crosstalk,low light efficiency,short viewing distance,and the manufacturing is difficulty.Based on the principle of naked-eye 3D display and the Fresnel optical theory,this paper designs a Fresnel lens array and the star-shaped liquid crystal display(LCD)switch of unit LCD screen to achieve low-crosstalk and high brightness uniformity for the autostereoscopic 3D display.The unit parameters of a 139.7 cm 4K model autostereoscopic 3D displayer are provided and they are optimized by the TracePro software.The results show that when the pitch of the Fresnel lens on the exit surface is 0.304 mm,the width of each serration of Fresnel lens is 0.0234 mm,the length of the Fresnel lens is 2.87 mm,and the center height of star-shaped LCD switch is 0.030 mm,the center length is 0.040 mm,the width of star-shaped LCD switch is 0.050 mm,and the image crosstalk is less than 2%when the viewing distance is 2.50 m.The problem on the brightness of the image in different positions is improved. 展开更多
关键词 naked eye D display fresnel optical theorythis d display fresnel lens array star shaped LCD switch Fresnel lens brightness uniformity CROSSTALK
原文传递
Implantation of a posterior chamber phakic intraocular lens on Bruch’s membrane opening-minimum rim width,retinal nerve fiber layer,and macular thickness
12
作者 Josefina Reñones Humberto Carreras +4 位作者 Alfonso Antón-López Ángel García-García Rafael Melián Juan Francisco Loro-Ferrer David P Piñero 《International Journal of Ophthalmology(English edition)》 2025年第9期1658-1664,共7页
AIM:To assess whether the implantation of a posterior chamber phakic intraocular lens produces changes in optical coherence tomography(OCT)measurements of macular thickness(MT)and two parameters that define the struct... AIM:To assess whether the implantation of a posterior chamber phakic intraocular lens produces changes in optical coherence tomography(OCT)measurements of macular thickness(MT)and two parameters that define the structure of the optic nerve,the peripapillary nerve fiber layer(RNFL)and the Bruch’s membrane opening-minimum rim width(BMO-MRW).METHODS:This nonrandomized prospective pre-post study included 86 eyes of 48 patients(age,20-47y;axial length:23.10-28.95 mm)scheduled for myopia or myopic astigmatism correction with implantation of the implantable collamer lens(ICL).Eyes with glaucoma or any other ocular disease that could alter OCT results were excluded.RNFL,BMO-MRW and MT were measured preoperatively,and at 1 and 6mo after surgery using spectral-domain OCT.Changes between preoperative and postoperative values were evaluated.RESULTS:There was a significant increase in BMOMRW at 1mo(mean change:3.48±15.07μm,P=0.041).No significant changes were found during the rest of followup(1-6mo postop.,P=0.623).There was also a significant increase in RNFL thickness at 1mo af ter surger y(1.45±2.18μm,P<0.001),but with a significant reduction from 1 to 6mo postoperatively(P=0.002).Regarding MT,it increased significantly at 1mo(2.46±3.76μm,P<0.001),with a significant decrease afterwards(P=0.048).Measurements of the three parameters at 6mo were slightly superior to preoperative values(P<0.01).CONCLUSION:Minimal changes are induced in BMOMRW,RNFL and MT after ICL implantation in healthy eyes,confirming the safety of the surgical procedure regarding the structure of the optic nerve head and the macula,and indicating that this phakic intraocular lens seems to have a slight impact on OCT measurements. 展开更多
关键词 implantable collamer lens phakic intraocular lens posterior chamber macular thickness macular edema optical coherence tomography
原文传递
Feasibility of utilizing a software-based fitting system for orthokeratology lens recordering without short-term discontinuation of lens wear
13
作者 Mingxin Lu Shengsong Xu +6 位作者 Jinyun Jiang Zhouyue Li Ling Jin Hongmei Tan Weiyin Chen Cong Li Xiao Yang 《Eye Science》 2025年第3期248-265,共18页
Objective:To evaluate the performance of orthokeratology(ortho-k)lens reordering using software-designed system,so as to determine the feasibility of ortho-k lens reordering without discontinuing lens wear.Methods:Thi... Objective:To evaluate the performance of orthokeratology(ortho-k)lens reordering using software-designed system,so as to determine the feasibility of ortho-k lens reordering without discontinuing lens wear.Methods:This study is a retrospective analysis of data of ortho-k lens wearers who had a history of short-term discontinuation of lens wear.A total of 94 individuals aged over 8 years with spherical equivalent refraction ranging from-0.50 to-6.50 diopters were included.The corneal topography data at baseline(before ortho-k)and after lens wear discontinuation(cessation of ortho-k treatment)were imported separately into the lens-design software,along with corresponding refraction data.Subsequently,corneal and lens parameters were generated and compared.Intraclass correlation coefficients(ICC)were calculated,and Bland and Altman analyses were conducted.Results:All 94 children were involved in the retrospective analysis.Compared with baseline data,there was a high level of consistency between Rwo(without discontinuation)and Rwith(with discontinuation),with an ICC of 0.96(P<0.001).Furthermore,the comparison of lens parameters generated by the Easyfit software between baseline and after short-term discontinuation showed a high degree of consistency,with all of the ICC values exceeding 0.90.Similar results were obtained using the WAVE software,as both ICC values and Bland-Altman plots demonstrated a high level of consistency in lens parameters between two conditions(nearly all data points fell within the 95%LoAs).Conclusions:It is feasible to directly reorder new ortho-k lenses using software fitting approaches.However,further investigations are necessary to validate their practicability in a clinical setting. 展开更多
关键词 lens wear discontinuation ORTHOKERATOLOGY corneal topography SOFTWARE lens reorder
暂未订购
Research and Application Progress of Intraocular Lens Power Calculation Formulas in the Era of Refractive Cataract Surgery
14
作者 Bowei Liang Jinhua Wang +1 位作者 Yao Chen Pan Liu 《Journal of Biosciences and Medicines》 2025年第2期348-356,共9页
As cataract surgery progresses from “restoration of sight” to “refractive correction”, precise prediction of intraocular lens (IOL) power is critical for enhancing postoperative visual quality in patients. IOL pow... As cataract surgery progresses from “restoration of sight” to “refractive correction”, precise prediction of intraocular lens (IOL) power is critical for enhancing postoperative visual quality in patients. IOL power calculation methods have evolved and innovated throughout time, from early theoretical and regression formulas to nonlinear formulas for estimating effective lens position (ELP), multivariable formulas, and innovative formulas that use optical principles and AI-based online formulas. This paper thoroughly discusses the development and iteration of traditional IOL calculation formulas, the emergence of new IOL calculation formulas, and the selection of IOL calculation formulas for different patients in the era of refractive cataract surgery, serving as a reference for “personalized” IOL implantation in clinical practice. 展开更多
关键词 Cataract Surgery Intraocular lens Power Calculation Formula Refractive Cataract lens Power Calculation
在线阅读 下载PDF
Scleral-fixation of the Akreos^(R)AO60 lens in vitrectomized eyes:a retrospective analysis of outcomes and complications with emphasis on intraocular lens opacification
15
作者 Corrina P.Azarcon Carmina Tricia A.Raralio +1 位作者 Martin D.Hyrcza Amin Kherani 《Annals of Eye Science》 2025年第3期62-72,共11页
Background:The Akreos®AO60 intraocular lens(IOL)has been employed for scleral fixation in eyes without capsular support,although surgical complications,including IOL opacification,have been reported.This study ai... Background:The Akreos®AO60 intraocular lens(IOL)has been employed for scleral fixation in eyes without capsular support,although surgical complications,including IOL opacification,have been reported.This study aims to evaluate the outcomes and complications associated with scleral fixation of the Akreos®AO60 IOL in vitrectomized eyes,with a particular focus on IOL opacification.Methods:Electronic medical records of consecutive eyes that underwent scleral-fixation of the Akreos®AO60 lens using Gore-tex®sutures from 2017 to 2022 were reviewed.The following parameters were collected:age,sex,laterality,past ocular/medical history,surgical indication,pre-operative visual acuity(VA)and intraocular pressure(IOP),surgical procedure,and post-operative VA and IOP.The types of complications,onset,management,and outcomes were also documented.Descriptive statistics,Wilcoxon signed-rank test,and Fisher’s exact test were employed for statistical analysis.Results:Eighty-nine eyes of 86 patients aged 31-100 years were included.The most common surgical indication was non-traumatic IOL displacement.Retinal tears and localized choroidal hemorrhage were found intraoperatively in 7.9%and 1.1%,respectively.The most common post-operative complications were vitreous hemorrhage(13.5%),corneal edema(12.4%),ocular hypotony(11.2%),and IOL opacification(11.2%).IOL opacification was associated with intra-/post-operative exposure to air/gas[odds ratio(OR):12.24;95%confidence interval(CI),1.46-103.0;P=0.006].Mean logarithm of the minimum angle of resolution(logMAR)best-reported VA(BRVA)improved from 1.22±0.77 pre-operatively to 0.56±0.67 on latest follow-up(P<0.001).Conclusions:The majority of the complications from scleral-fixation of the Akreos®AO60 lens in vitrectomized eyes were mild and transient;however,a proportion required surgical intervention.A significant risk for opacification was found in IOLs exposed to air/gas,although VA was often maintained. 展开更多
关键词 Scleral-fixated intraocular lens(scleral-fixated IOL) COMPLICATIONS intraocular lens opacification(IOL opacification) VITRECTOMY
暂未订购
Strong gravitational lensing of a fivedimensional charged,equally rotating black hole with a cosmological constant
16
作者 Md Sabir Ali Shagun Kaushal Yu-Xiao Liu 《Communications in Theoretical Physics》 2025年第7期153-170,共18页
We study the lensing phenomena of the strong gravity regime of five-dimensional charged,equally rotating black holes with a cosmological constant,familiarly known as the Cvetic–Lu–Pope(CLP)black holes.These black ho... We study the lensing phenomena of the strong gravity regime of five-dimensional charged,equally rotating black holes with a cosmological constant,familiarly known as the Cvetic–Lu–Pope(CLP)black holes.These black holes are characterized by three observable parameters,the mass M,the charge Q and the angular momentum J,in addition to the cosmological constant.We investigate the strong gravitational lensing observables,mainly the photon sphere radius,the minimum impact parameter,the deflection angle,the angular size,and the magnification of the relativistic images.We model the M87 and SgrA*for these observables.We also focus on the relativistic time delay effect in the strong-field regime of gravity and the impact of the observable on it.The analytical expressions for the observables of the relativistic images with vanishing angular momentum(j=0)are discussed in some detail.We shed a light on the gravitational time delay effect by incorporating the lensing observables.The gravitational time delay has a direct consequence on the photon sphere radius and hence on the quasinormal modes. 展开更多
关键词 black hole strong lensing phenomena time delay effect M87 and SgrA^(*) lensing observables
原文传递
Comparison of bilateral implantation of extended depth-of-focus intraocular lens and mix-and-match implantation of extended depth-of-focus intraocular lens with a diffractive bifocal intraocular lens 被引量:1
17
作者 Li Tong Li Zhuoya +2 位作者 Guo Rong Hu Xiaomin Zhang Hui 《国际眼科杂志》 2025年第3期337-343,共7页
AIM:To compare the clinical outcomes of extended depth-of-focus intraocular lenses(EDOF IOLs)using either micromonovision implantation or mixed implantation of EDOF and diffractive bifocal IOLs.METHODS:This retrospect... AIM:To compare the clinical outcomes of extended depth-of-focus intraocular lenses(EDOF IOLs)using either micromonovision implantation or mixed implantation of EDOF and diffractive bifocal IOLs.METHODS:This retrospective clinical trial included 130 patients(260 eyes),who were divided into two groups.Group RR comprised 70 patients(140 eyes)bilaterally implanted with ZXR00 IOLs(Tecnis ZXR00,where one target was-0.5 D to-0.75 D and the other was 0 to-0.25 D).Group RM comprised 60 patients(120 eyes)unilaterally implanted with both ZXR00 and ZMB00 IOLs(Tecnis ZMB00,0 to-0.25 D).Postoperative outcomes were compared after 3 mo,including visual acuity,defocus curves,stereoacuity,modulation transfer functions(MTFs),higher-order aberrations,and Visual Function-14(VF-14)questionnaire responses.RESULTS:Group RR had superior bilateral intermediate vision,while the group RM had superior bilateral near vision(both P<0.05).Group RM also exhibited superior MTFs and reduced higher-order aberrations(both P<0.05).Stereoacuity and VF-14 questionnaire results showed no statistically significant difference between groups(P>0.05).CONCLUSION:The implantation of micromonovision has significantly improved near vision.IOLs and their collocation can be customized according to individual patient needs to achieve precise treatment and provide cataract patients with high-quality vision. 展开更多
关键词 extended depth-of-focus(EDOF)intraocular lens Tecnis ZMB00 defocus curve micromonovision mix-and-match vision
暂未订购
Sutured scleral fixation of existing subluxated/dislocated acrylic one-piece intraocular lenses
18
作者 Wei-Yu Huang Yung-Jen Chen 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第4期665-669,共5页
AIM:To evaluate the visual and refractive outcomes in cases after sutured scleral fixation of existing subluxated or dislocated acrylic one-piece intraocular lenses(IOLs).METHODS:This study retrospectively enrolled a ... AIM:To evaluate the visual and refractive outcomes in cases after sutured scleral fixation of existing subluxated or dislocated acrylic one-piece intraocular lenses(IOLs).METHODS:This study retrospectively enrolled a consecutive series of patients who underwent a surgery of sutured existing subluxated or dislocated IOLs from October 2018 to June 2020.All patients underwent comprehensive preoperative and postoperative ophthalmologic examination,and data were collected including age,sex,surgical indications,best-corrected visual acuity,refractive error,intraocular pressure.Presence of intraoperative and postoperative surgical complications was documented.RESULTS:A total of 20 consecutive cases were enrolled for analysis with mean final follow-up period 9.8±5.3mo.Visual acuity improved from a mean of 0.35(0.46±0.32 logMAR)preoperatively to 0.61(0.21±0.18 logMAR)at the 3-month follow-up(P=0.002).The mean amount of preoperative keratometric astigmatism and total postoperative refractive astigmatism was-1.24±0.80 diopters(D)and-1.42±0.97 D,respectively.There was no statistically significant difference between preoperative and postoperative astigmatism(P=0.156).The mean IOL-induced astigmatism was-0.23±0.53 D.The mean spherical equivalent at the 3-month follow-up was-0.1±0.94 D.No major complications were noted during the follow-up period.CONCLUSION:Surgical techniques using sutured scleral fixation of existing subluxated or dislocated acrylic one-piece IOLs result in favorable visual and refractive outcomes without major complications. 展开更多
关键词 intraocular lens dislocation intraocular lens subluxation lens dislocation lens subluxation scleral fixation
原文传递
Outcomes of a non-diffractive extended depth of focus intraocular lens in patients with well-controlled glaucoma and ocular hypertension
19
作者 Jia-Ru Liu Andrei-Alexandru Szigiato Paul Harasymowycz 《International Journal of Ophthalmology(English edition)》 2025年第1期79-85,共7页
AIM:To assess visual outcomes and satisfaction of a non-diffractive extended depth of focus(EDOF)intraocular lens(IOL)in individuals with ocular hypertension(OHT)and well-controlled mild glaucoma undergoing cataract s... AIM:To assess visual outcomes and satisfaction of a non-diffractive extended depth of focus(EDOF)intraocular lens(IOL)in individuals with ocular hypertension(OHT)and well-controlled mild glaucoma undergoing cataract surgery.METHODS:An investigator-initiated,single-center,prospective,interventional,noncomparative study conducted in Montreal,Canada.The study enrolled 31 patients(55 eyes)with OHT or mild glaucoma who received a non-diffractive EDOF IOL(Acrysof IQ Vivity).Participants underwent sequential cataract surgery with the Vivity IOL.Follow-up evaluations occurred at 1d,1,and 3mo postoperatively,assessing uncorrected distance,intermediate,and near visual acuity.Questionnaires(QUVID:Questionnaire for visual disturbances and IOLSAT:Intraocular lens satisfaction)were administered pre and post-operatively to measure visual disturbances and spectacle independence in various lighting.Safety parameters included intraocular pressure(IOP),glaucoma medications,spherical equivalence,mean deviation and pattern standard deviation or square root of lost variance on Octopus visual field.RESULTS:At 1 and 3mo postoperatively,significant improvements were observed in uncorrected distance and intermediate visual acuity.Spectacle independence was enhanced for distance and intermediate vision,especially in bright light settings.Spectacle-free intermediate vision was improved even in dim lighting.Visual disturbances,particularly glare symptoms,were reduced,and there was a notable decrease in IOP and glaucoma medication burden at 3mo.There was more hazy vision postoperatively with no impact on visual acuity and visual satisfaction.CONCLUSION:The non-diffractive EDOF lens improves distance and intermediate spectacle-free visual function in patients with OHT and well-controlled glaucoma.The findings highlight significant improvements in visual acuity,reduced glare,enhanced spectacle independence,and improved visual performance in different lighting conditions. 展开更多
关键词 extended depth of focus refractive GLAUCOMA ocular hypertension CATARACT intraocular lens
原文传递
Optical-Focused Fresnel Lens for Generating Electricity Output Using Multiple Layers of Heated Disks with Water as a Medium
20
作者 Hung-Te Henry Su Po-Han Lee 《Journal of Environmental Science and Engineering(B)》 2025年第2期76-80,共5页
Concentrated solar thermal power generation has been experimentally tested in advanced countries for a period of time.This paper demonstrates how this technology can be improved by using water molecules as a medium to... Concentrated solar thermal power generation has been experimentally tested in advanced countries for a period of time.This paper demonstrates how this technology can be improved by using water molecules as a medium to drive traditional generator sets for energy conversion,thereby simultaneously improving the energy conversion rate.Additionally,a novel contribution is made by incorporating a magic number 4 to enhance the focusing efficiency of Fresnel lenses,which drives improvements in power generation output and QE(Quantum Efficiency). 展开更多
关键词 Energy conversion rate Fresnel lens generator sets solar power volume factors magic number 4 QE
在线阅读 下载PDF
上一页 1 2 161 下一页 到第
使用帮助 返回顶部