Laser spectroscopic imaging techniques have received tremendous attention in the-eld of cancer diagnosis due to their high sensitivity,high temporal resolution,and short acquisition time.However,the limited tissue pen...Laser spectroscopic imaging techniques have received tremendous attention in the-eld of cancer diagnosis due to their high sensitivity,high temporal resolution,and short acquisition time.However,the limited tissue penetration of the laser is still a challenge for the in vivo diagnosis of deep-seated lesions.Nanomaterials have been universally integrated with spectroscopic imaging techniques for deeper cancer diagnosis in vivo.The components,morphology,and sizes of nanomaterials are delicately designed,which could realize cancer diagnosis in vivo or in situ.Considering the enhanced signal emitting from the nanomaterials,we emphasized their combination with spectroscopic imaging techniques for cancer diagnosis,like the surface-enhanced Raman scattering(SERS),photoacoustic,fluorescence,and laser-induced breakdown spectroscopy(LIBS).Applications ofthe above spectroscopic techniques offer new prospectsfor cancer diagnosis.展开更多
Collinear laser spectroscopy is a powerful tool for studying the nuclear spins,electromagnetic moments,and charge radii of exotic nuclei.To study the nuclear properties of unstable nuclei at the Beijing Radioactive Io...Collinear laser spectroscopy is a powerful tool for studying the nuclear spins,electromagnetic moments,and charge radii of exotic nuclei.To study the nuclear properties of unstable nuclei at the Beijing Radioactive Ion-beam Facility(BRIF)and the future High Intensity Heavy-ion Accelerator Facility(HIAF),we developed a collinear laser spectroscopy apparatus integrated with an offline laser ablation ion source and a laser system.The overall performance of this state-of-the-art technique was evaluated,and the system was commissioned using a bunched stable ion beam.The high-resolution optical spectra for the 4s ^(2)S_(1/2)→4p^(2)P_(3/2)(D2)ionic transition of ^(40;42;44;48)Ca isotopes were successfully measured.The extracted isotope shifts relative to ^(40)Ca showed excellent agreement with the literature values.This system is now ready for use at radioactive ion beam facilities such as the BRIF and paves the way for the further development of higher-sensitivity collinear resonance ionization spectroscopy techniques.展开更多
A control and data acquisition system was implemented for the recently developed collinear laser spectroscopy setup.This system is dedicated to data recording,storage,processing,monitoring of the beam intensity and en...A control and data acquisition system was implemented for the recently developed collinear laser spectroscopy setup.This system is dedicated to data recording,storage,processing,monitoring of the beam intensity and energy,and visualization of various spectra.In comparison to the conventional resonance nuclear reaction system,the key technique is the precise synchronization of the detected counts with the actual scanning voltage(or probing laser frequency).The functions of the system were tested by measuring the hyperfine structure spectra of stable calcium(e.g.,^(40)Ca^(+))and radioactive potassium(e.g.,^(38)K)in the bunched and continuous modes,respectively.This system will be routinely applied and further improved in subsequent laser spectroscopy experiments on unstable isotopes at the Beijing Radioactive Ion-beam Facility(BRIF).展开更多
The sub-Doppler absorption laser spectroscopy at 728nm transition from the 5D5/2 state to the 6F state of cesium with linewidth near 10 MHz is first experimentally performed with indirect pumping from the ground state...The sub-Doppler absorption laser spectroscopy at 728nm transition from the 5D5/2 state to the 6F state of cesium with linewidth near 10 MHz is first experimentally performed with indirect pumping from the ground state 6S1/2 to the state 7P3/2 by a 455.5nm diode laser. Using a 455.5nm diode laser as an indirect pump laser, several excited states will be populated due to spontaneous decay from the 7P state. We first implement the sub-Doppler absorption laser spectroscopy at 728nm from the 5D5/2 state to the 6F state when Cs atoms within thermal glass cell decay to the 5D5/2 state. Due to velocity transfer effect, the hyperfine structure of 5D5/2 shows a mixed and complicated pattern but very e/ear structure when the 455.5nm pumping laser is counter-propagating (or co-propagating) with the 728nm probing laser.展开更多
Natural radiative lifetimes of five higher-lying odd-parity levels 5pTs ^3P1^0, 5p5d 1P1^0, 5p6d 3F2^0, 3D1^0 and 3F3^0 in neutral tin are measured by the time-resolved laser-induced fluorescence (TR-LIF) technique ...Natural radiative lifetimes of five higher-lying odd-parity levels 5pTs ^3P1^0, 5p5d 1P1^0, 5p6d 3F2^0, 3D1^0 and 3F3^0 in neutral tin are measured by the time-resolved laser-induced fluorescence (TR-LIF) technique and the atomic beam method. All these lifetimes are not longer than 100 ns and they are found to be shorter than the lifetimes of evenparity levels in the same energy region. The results reported in this paper provide important transition parameters for highly-excited atomic Sn, which may be useful for theoretically calculating excited heavy atoms.展开更多
We present a differential laser absorption spectroscopy(DLAS)system operating at 1550 nm for rapid and sensitive gas concentration measurements.A dual-wavelength toggling mechanism is presented,which significantly red...We present a differential laser absorption spectroscopy(DLAS)system operating at 1550 nm for rapid and sensitive gas concentration measurements.A dual-wavelength toggling mechanism is presented,which significantly reduces data processing,hence supporting a high update rate and data robustness against fast-changing environmental conditions.We showcase the ability to toggle between two wavelengths separated by 90 pm in 14μs and with minimal chirp(~1 pm),facilitating sensitive DLAS measurements at 8 kHz update rate.This performance is achieved by driving a 1550 nm diode laser with a modified square-wave current pulse,overcoming the thermal time constant limited wavelength-modulation response of the diode laser.A sensitive feedback mechanism ensures excellent long-term wavelength stability better than 1.4 pm peak-to-peak at 8 kHz toggling over 20 h,As a performance test,we measured the volumetric ratio(VMR)of hydrogen cyanide(HCN)gas in a fiber-coupled gas cell with lessthan 0.2%peak-to-peak variation over 20 h at 40 Hz.A best sensitivity in VMR of 8×10^(-6) was achieved at 25 ms integration time.The simplicity and high update rate of our system make it well-suited for gas monitoring in dynamic atmospheric and industrial environments.Further,it offers potential utility in applications requiring precise wavelength control,such as injection seeding of pulsed lasers.A simple analytical model is derived,which,in detail,supports the experimental results,hence offering a tool for future design optimization.展开更多
Scrap metals are typically covered with surface contaminants,such as paint,dust,and rust,which can significantly affect the emission spectrum during laser-induced breakdown spectroscopy(LIBS)based sorting.In this stud...Scrap metals are typically covered with surface contaminants,such as paint,dust,and rust,which can significantly affect the emission spectrum during laser-induced breakdown spectroscopy(LIBS)based sorting.In this study,the effects of paint layers on metal surfaces during LIBS classification were investigated.LIBS spectra were collected from metal surfaces painted with black and white paints by ablation with a nanosecond pulsed laser(wavelength=1064 nm,pulse width=7 ns).For the black-painted samples,the LIBS spectra showed a broad background emission,emission lines unrelated to the target metals,large shot-to-shot variation,and a relatively low signal intensity of the target metal,causing poor classification accuracy even at high shot numbers.Cleaning the black paint layer by ablating over a wide area prior to LIBS analysis resulted in high classification accuracy with fewer shot numbers.A method to determine the number of cleaning shots necessary to obtain high classification accuracy and high throughput is proposed on the basis of the change in LIBS signal intensity during cleaning shots.For the white-painted samples,the paint peeled off the metal surface after the first shot,and strong LIBS signals were measured after the following shot,which were attributed to the nanoparticles generated by the ablation of the paint,allowing an accurate classification after only two shots.The results demonstrate that different approaches must be employed depending on the paint color to achieve high classification accuracy with fewer shot numbers.展开更多
The measurement of the combustion characteristics of a single biomass particle is essential for studying massive biofuel energy conversion process;however,it is challenging due to the small physical scale of the bioma...The measurement of the combustion characteristics of a single biomass particle is essential for studying massive biofuel energy conversion process;however,it is challenging due to the small physical scale of the biomass particle flame.In this work,we report an investigation of the combustion behavior of single lignin and single cellulose particle through CO_(2)absorption spectroscopy and high-speed photography.The biomass samples are prepared with an initial diameter of about 1.0 mm and are ignited on a heating plate placed inside a multi-pass absorption cell.The shape and size transformation of single biomass particle are recorded through high-speed photography,and the combustion temperature and CO_(2)column densities are measured through laser absorption spectroscopy at 4.172µm.We find that the maximum combustion temperatures are 1662±38 K and 1569±26 K for lignin and cellulose particle,respectively.Besides,we find that CO_(2)generation precedes the generation of visible volatile flame for cellulose particle.While for lignin particle,the CO_(2)generation is found to be almost at the same time as its volatile combustion stage begins.The measurement technique and results presented in this work are of practical interest for biomass combustion studies and arc meaningful for the development of biomass thermal conversion mode.展开更多
We report the experimental demonstration of transform-limited sub-6 fs pulses at an optimal central wavelength by a tunable noncollinear optical parametric amplification(NOPA) source. Meanwhile, a white light contin...We report the experimental demonstration of transform-limited sub-6 fs pulses at an optimal central wavelength by a tunable noncollinear optical parametric amplification(NOPA) source. Meanwhile, a white light continuum in the near-infrared(NIR) range from 900 to 1100 nm is also successfully generated by focusing the unconverted800 nm beam during NOPA generation on a sapphire rod. Both visible-pump/visible-probe and visible-pump/NIR-probe experiments are realized using the same laser system. As examples, ultrafast photo-induced exciton dynamics inside two kinds of materials are investigated by the visible-pump/visible-probe and visible-pump/NIR-probe spectroscopy, respectively.展开更多
In this work, Laser Induced Breakdown Spectroscopy (LIBS) was used to determine the constituent of Gum Arabic (<i><span>Acacia nilotica</span></i><span>) collected from five different loc...In this work, Laser Induced Breakdown Spectroscopy (LIBS) was used to determine the constituent of Gum Arabic (<i><span>Acacia nilotica</span></i><span>) collected from five different locations in Sudan. Gum samples were irradiated with 80 mJ pulse energy of Nd-YAG laser (1064 nm) and Atomic spectra Database was used for the spectral analysis of the plasma emitted from these samples. It was found that the samples contain the elements C, O, H, S, N, P, Na, Mg, Ca, Fe, Cr, Mn, Co with different amounts. Some elements like (Ti, Br, Ar, Th, Kr, Sc and Pr) are recorded here for the first time.</span>展开更多
High-resolution atomic-beam laser spectroscopy has been performed to study Stark effect of Ba atom. Stark spectra have been observed at various electric fields for Ba highly excited states. The scalar polarizability o...High-resolution atomic-beam laser spectroscopy has been performed to study Stark effect of Ba atom. Stark spectra have been observed at various electric fields for Ba highly excited states. The scalar polarizability of the transition from 6s5d3D2 to 5d6p3F3 at 728.0 nm and the tensor polarizability of the 3F3 level have been determined for the first time, to be αs = -89.8 (12) kHz/(kV/cm)2 and αt = -133.7 (20) kHz/(kV/cm)2, respectively.展开更多
This study investigates the optical properties of sesame oil from traditional and industrial sources using a custom-designed semiconductor laser spectrometer, UV-Vis spectroscopy, and FTIR spectroscopy. Six samples we...This study investigates the optical properties of sesame oil from traditional and industrial sources using a custom-designed semiconductor laser spectrometer, UV-Vis spectroscopy, and FTIR spectroscopy. Six samples were collected from traditional presses and factories in Khartoum State and White Nile State. The spectrometer, constructed with a 680 nm semiconductor laser and various resistor values, measured the absorbance of sesame oil samples. UV-Vis spectroscopy identified absorbance peaks at 670 nm and 417 nm, corresponding to chlorophyll a and b. FTIR analysis showed nearly identical spectra among the samples, indicating similar chemical compositions. Laser spectrometer analysis revealed specific absorbance values for each sample. The results highlight the feasibility of using a 680 nm semiconductor laser for analyzing sesame oil, providing a cost-effective alternative to other wavelengths. This study demonstrates the potential of integrating traditional methods with modern spectroscopic techniques for the quality assessment of sesame oil.展开更多
The laser induced breakdown spectroscopy(LIBS) is an element analysis technique with the advantages of real time detection,simultaneous multi-element identification,and in-situ and stand-off capacities.To evaluate its...The laser induced breakdown spectroscopy(LIBS) is an element analysis technique with the advantages of real time detection,simultaneous multi-element identification,and in-situ and stand-off capacities.To evaluate its potential of ocean applications,in this paper,the time resolved laser-induced breakdown spectroscopy for calcium concentration detection in water is investigated.With the optimum experimental parameters,the plasma emission lifetime is determined to be about 500 ns with 532 nm laser excitation,and 1000 ns with 1064 nm laser excitation.The lowest detection concentration of 50 ppm is achieved for calcium detection in CaCl2 water solution using the 532 nm LIBS.Even better detection sensitivity is achieved using the 1064 nm LIBS,and the resulted lowest detection concentration of calcium is 25 ppm.The results suggest that it is feasible to develop LIBS as an on-line sensor for metal element monitoring in the sea.展开更多
Spatial confinement has great potential for Laser Induced Breakdown Spectroscopy (LIBS) instruments after it has been proven that it has the ability to enhance the LIBS signal strength and repeatability. In order to...Spatial confinement has great potential for Laser Induced Breakdown Spectroscopy (LIBS) instruments after it has been proven that it has the ability to enhance the LIBS signal strength and repeatability. In order to achieve in-situ measurement of heavy metals in farmland soils by LIBS, a hemispherical spatial confinement device is designed and used to collect plasma spectra, in which the optical fibers directly collect the breakdown spectroscopy of the soil samples. This device could effectively increase the stability of the spectrum intensity of soil. It also has other advantages, such as ease of installation, and its small and compact size. The relationship between the spectrum intensity and the laser pulse energy is studied for this device. It is found that the breakdown threshold is 160 cm-2, and when the laser fluence increases to 250 J/cm2, the spectrum intensity reaches its maximum. Four different kinds of laser pulse energy were set up and in each case the limits of detection of Cd, Cu, Ni, Pb and Zn were calculated. The results show that when the laser pulse fluence was 2.12 GW/cm2, we obtained the smallest limits of detection of these heavy metals, which are all under 10 mg/kg. This device can satisfy the needs of heavy metal in-situ detection, and in the next step it will be integrated into a portable LIBS instrument.展开更多
In this paper the spectral enhancement of laser-induced breakdown spectroscopy (LIBS) for copper plasma in the presence of a magnetic field is investigated and the temporal- and spatial-resolved plasma emission spec...In this paper the spectral enhancement of laser-induced breakdown spectroscopy (LIBS) for copper plasma in the presence of a magnetic field is investigated and the temporal- and spatial-resolved plasma emission spectra are analyzed. Experimental results show that the copper plasma atomic and ion spectra have been enhanced in the presence of the external magnetic field. In addition, the Cu I 521.82 nm spectral intensity evolution with delay time appears to have a double peak around the delay time of 2 μs, but that of Cu II 507.57 nm has a sharp decrease because of the electron-atom three body recombination process. The plasma temperature with magnetic confinement is lower than that of the case in the absence of magnetic fields. Finally, the spectral enhancement mechanisms of laser induced breakdown spectroscopy with magnetic confinement are analyzed.展开更多
Exhaust gas temperature is an important factor in NOx, THC and PM emissions of engines. Especially 2D temperature and concentration distribution plays an important role for the engine efficiency. A thermocouple is int...Exhaust gas temperature is an important factor in NOx, THC and PM emissions of engines. Especially 2D temperature and concentration distribution plays an important role for the engine efficiency. A thermocouple is intrinsically a point temperature measurement method and noncontact 2D temperature distribution cannot be attained by thermocouples. Recently, as a measurement technique with high sensitivity and high response, laser diagnostics has been developed and applied to the actual engine combustions. With these engineering developments, transient phenomena such as start-ups and load changes in engines have been gradually elucidated in various conditions. In this study, the theoretical and experimental research has been conducted in order to develop the noncontact and fast response 2D temperature and concentration distribution measurement method. The method is based on a Computed Tomography (CT) method using absorption spectra of water vapor at 1388 nm. It has been demonstrated that the method has been successfully applied to engine exhausts to measure 2D temperature distributions.展开更多
Aqueous ruthenium was detected in real-time under ambient conditions using microwaveassisted laser-induced breakdown spectroscopy(MW-LIBS).A 10 mJ laser energy and 750 W microwave power were directed at an open liquid...Aqueous ruthenium was detected in real-time under ambient conditions using microwaveassisted laser-induced breakdown spectroscopy(MW-LIBS).A 10 mJ laser energy and 750 W microwave power were directed at an open liquid jet sample of ruthenium.It was observed that,for liquid flow,the coupling efficiency between the microwave and the laser-induced plasma was limited to 43%.The improvement in the ruthenium’s signal-to-noise ratio with MW-LIBS,with respect to LIBS,was 76-fold.Based on MW-LIBS,the limit of detection for aqueous ruthenium was determined to be 957±84 ppb.展开更多
Densities of Ar metastable states 1s5 and 1s3 are measured by using the tunable diode laser absorption spectroscopy(TDLAS) in Ar and Ar/O2 mixture dual-frequency capacitively coupled plasma(DF-CCP). We investigate...Densities of Ar metastable states 1s5 and 1s3 are measured by using the tunable diode laser absorption spectroscopy(TDLAS) in Ar and Ar/O2 mixture dual-frequency capacitively coupled plasma(DF-CCP). We investigate the effects of high-frequency(HF, 60 MHz) power, low-frequency(LF, 2 MHz) power, and working pressure on the density of Ar metastable states for three different gas components(0%, 5%, and 10% oxygen mixed in argon). The dependence of Ar metastable state density on the oxygen content is also studied at different working pressures. It is found that densities of Ar metastable states in discharges with different gas components exhibit different behaviors as HF power increases. With the increase of HF power, the metastable density increases rapidly at the initial stage, and then tends to be saturated at a higher HF power. With a small fraction(5% or 10%) of oxygen added in argon plasma, a similar change of the Ar metastable density with HF power can be observed, but the metastable density is saturated at a higher HF power than in the pure argon discharge. In the DF-CCP, the metastable density is found to be higher than in a single frequency discharge, and has weak dependence on LF power. As working pressure increases, the metastable state density first increases and then decreases,and the pressure value, at which the density maximum occurs, decreases with oxygen content increasing. Besides, adding a small fraction of oxygen into argon plasma will significantly dwindle the metastable state density as a result of quenching loss by oxygen molecules.展开更多
A metal-assisted method is proposed for the evaluation of gases’molecular abundance ratio in fiber-optic laser-induced breakdown spectroscopy(FO-LIBS).This method can reduce the laser ablation energy and make gas com...A metal-assisted method is proposed for the evaluation of gases’molecular abundance ratio in fiber-optic laser-induced breakdown spectroscopy(FO-LIBS).This method can reduce the laser ablation energy and make gas composition identification possible.The principle comes from the collision between the detected gases and the plasma produced by the laser ablation of the metal substrate.The interparticle collision in the plasma plume leads to gas molecules dissociating and sparking,which can be used to determine the gas composition.The quantitative relationship between spectral line intensity and molecular abundance ratio was developed over a large molecular abundance ratio range.The influence of laser ablation energy and substrate material on gas quantitative calibration measurement is also analyzed.The proposed metal-assisted method makes the measurement of gases’molecular abundance ratios possible with an FO-LIBS system.展开更多
At present, heavy metal pollution in food occurs frequently, which requires a novel method for rapid detection. Laser induced breakdown spectroscopy (LIBS) is a new technique for rapid and environmental friendly det...At present, heavy metal pollution in food occurs frequently, which requires a novel method for rapid detection. Laser induced breakdown spectroscopy (LIBS) is a new technique for rapid and environmental friendly detection, but it lacks high sensitivity and stability which restrict its development. In this study, Cr-polluted infant milk powder was used as experimental material to explore the feasibility of the application of LIBS technique in food safety detection. Aiming at improving the precision and accuracy of Cr detection by LIBS technique, LIBS spectra of samples were collected by a spectrometer with an intensified charge-cou- pled device (ICCD) using three gratings with different resolutions to comprehensively compare and analyze the stability, sensitivity and quantitative analysis accura- cy of LIBS detection. The results showed that average relative standard deviation (RSD) of LIBS spectral intensity was below 10%, indicating good stability. LIBS signals were collected by three gratings for quantitative analysis, and the results demonstrated that the linear correlation coefficient R2 of fitting curves was 0. 248 87, 0.903 12 and 0.992 81, respectively; the relative errors between actual and predicted concentrations were 38.23%, 8.84% and 7.43%, respectively, indicating that gratings with higher resolutions could lead to higher linear correlation coefficient and better detection accuracy. According to the results, high-resolu- tion spectrometer could significantly improve the accuracy of LIBS detection of Cr concentration in milk powder, suggesting that it is feasible to detect heavy metals in food by LIBS technique with the improvement of core device performance.展开更多
基金support from the Sichuan Science and Technology Program(2019ZDZX0036)the support from the Analytical&Testing Center of Sichuan University.
文摘Laser spectroscopic imaging techniques have received tremendous attention in the-eld of cancer diagnosis due to their high sensitivity,high temporal resolution,and short acquisition time.However,the limited tissue penetration of the laser is still a challenge for the in vivo diagnosis of deep-seated lesions.Nanomaterials have been universally integrated with spectroscopic imaging techniques for deeper cancer diagnosis in vivo.The components,morphology,and sizes of nanomaterials are delicately designed,which could realize cancer diagnosis in vivo or in situ.Considering the enhanced signal emitting from the nanomaterials,we emphasized their combination with spectroscopic imaging techniques for cancer diagnosis,like the surface-enhanced Raman scattering(SERS),photoacoustic,fluorescence,and laser-induced breakdown spectroscopy(LIBS).Applications ofthe above spectroscopic techniques offer new prospectsfor cancer diagnosis.
基金supported by the National Natural Science Foundation of China(Nos.12027809,U1967201,11875073,11875074 and 11961141003)National Key R&D Program of China(No.2018YFA0404403)+1 种基金China National Nuclear Corporation(No.FA18000201)the State Key Laboratory of Nuclear Physics and Technology,Peking University(No.NPT2019ZZ02).
文摘Collinear laser spectroscopy is a powerful tool for studying the nuclear spins,electromagnetic moments,and charge radii of exotic nuclei.To study the nuclear properties of unstable nuclei at the Beijing Radioactive Ion-beam Facility(BRIF)and the future High Intensity Heavy-ion Accelerator Facility(HIAF),we developed a collinear laser spectroscopy apparatus integrated with an offline laser ablation ion source and a laser system.The overall performance of this state-of-the-art technique was evaluated,and the system was commissioned using a bunched stable ion beam.The high-resolution optical spectra for the 4s ^(2)S_(1/2)→4p^(2)P_(3/2)(D2)ionic transition of ^(40;42;44;48)Ca isotopes were successfully measured.The extracted isotope shifts relative to ^(40)Ca showed excellent agreement with the literature values.This system is now ready for use at radioactive ion beam facilities such as the BRIF and paves the way for the further development of higher-sensitivity collinear resonance ionization spectroscopy techniques.
基金supported by the National Natural Science Foundation of China (Nos.12027809,U1967201,11875073,11875074 and 11961141003)National Key R&D Program of China (No.2018YFA0404403)the State Key Laboratory of Nuclear Physics and Technology,Peking University (Nos.NPT2019ZZ02,NPT2020KFY17).
文摘A control and data acquisition system was implemented for the recently developed collinear laser spectroscopy setup.This system is dedicated to data recording,storage,processing,monitoring of the beam intensity and energy,and visualization of various spectra.In comparison to the conventional resonance nuclear reaction system,the key technique is the precise synchronization of the detected counts with the actual scanning voltage(or probing laser frequency).The functions of the system were tested by measuring the hyperfine structure spectra of stable calcium(e.g.,^(40)Ca^(+))and radioactive potassium(e.g.,^(38)K)in the bunched and continuous modes,respectively.This system will be routinely applied and further improved in subsequent laser spectroscopy experiments on unstable isotopes at the Beijing Radioactive Ion-beam Facility(BRIF).
基金Supported by the National Natural Science Foundation of China under Grant No 91436210
文摘The sub-Doppler absorption laser spectroscopy at 728nm transition from the 5D5/2 state to the 6F state of cesium with linewidth near 10 MHz is first experimentally performed with indirect pumping from the ground state 6S1/2 to the state 7P3/2 by a 455.5nm diode laser. Using a 455.5nm diode laser as an indirect pump laser, several excited states will be populated due to spontaneous decay from the 7P state. We first implement the sub-Doppler absorption laser spectroscopy at 728nm from the 5D5/2 state to the 6F state when Cs atoms within thermal glass cell decay to the 5D5/2 state. Due to velocity transfer effect, the hyperfine structure of 5D5/2 shows a mixed and complicated pattern but very e/ear structure when the 455.5nm pumping laser is counter-propagating (or co-propagating) with the 728nm probing laser.
基金supported by the National Natural Science Foundation of China (Grant No 10574056)the program for New Century Excellent Talents in University,China (Grant No NCET-05-0302)
文摘Natural radiative lifetimes of five higher-lying odd-parity levels 5pTs ^3P1^0, 5p5d 1P1^0, 5p6d 3F2^0, 3D1^0 and 3F3^0 in neutral tin are measured by the time-resolved laser-induced fluorescence (TR-LIF) technique and the atomic beam method. All these lifetimes are not longer than 100 ns and they are found to be shorter than the lifetimes of evenparity levels in the same energy region. The results reported in this paper provide important transition parameters for highly-excited atomic Sn, which may be useful for theoretically calculating excited heavy atoms.
文摘We present a differential laser absorption spectroscopy(DLAS)system operating at 1550 nm for rapid and sensitive gas concentration measurements.A dual-wavelength toggling mechanism is presented,which significantly reduces data processing,hence supporting a high update rate and data robustness against fast-changing environmental conditions.We showcase the ability to toggle between two wavelengths separated by 90 pm in 14μs and with minimal chirp(~1 pm),facilitating sensitive DLAS measurements at 8 kHz update rate.This performance is achieved by driving a 1550 nm diode laser with a modified square-wave current pulse,overcoming the thermal time constant limited wavelength-modulation response of the diode laser.A sensitive feedback mechanism ensures excellent long-term wavelength stability better than 1.4 pm peak-to-peak at 8 kHz toggling over 20 h,As a performance test,we measured the volumetric ratio(VMR)of hydrogen cyanide(HCN)gas in a fiber-coupled gas cell with lessthan 0.2%peak-to-peak variation over 20 h at 40 Hz.A best sensitivity in VMR of 8×10^(-6) was achieved at 25 ms integration time.The simplicity and high update rate of our system make it well-suited for gas monitoring in dynamic atmospheric and industrial environments.Further,it offers potential utility in applications requiring precise wavelength control,such as injection seeding of pulsed lasers.A simple analytical model is derived,which,in detail,supports the experimental results,hence offering a tool for future design optimization.
基金supported by the R&D Center for Valuable Recycling (Global-Top R&D Program)of the Ministry of Environment (No.2016002250003)。
文摘Scrap metals are typically covered with surface contaminants,such as paint,dust,and rust,which can significantly affect the emission spectrum during laser-induced breakdown spectroscopy(LIBS)based sorting.In this study,the effects of paint layers on metal surfaces during LIBS classification were investigated.LIBS spectra were collected from metal surfaces painted with black and white paints by ablation with a nanosecond pulsed laser(wavelength=1064 nm,pulse width=7 ns).For the black-painted samples,the LIBS spectra showed a broad background emission,emission lines unrelated to the target metals,large shot-to-shot variation,and a relatively low signal intensity of the target metal,causing poor classification accuracy even at high shot numbers.Cleaning the black paint layer by ablating over a wide area prior to LIBS analysis resulted in high classification accuracy with fewer shot numbers.A method to determine the number of cleaning shots necessary to obtain high classification accuracy and high throughput is proposed on the basis of the change in LIBS signal intensity during cleaning shots.For the white-painted samples,the paint peeled off the metal surface after the first shot,and strong LIBS signals were measured after the following shot,which were attributed to the nanoparticles generated by the ablation of the paint,allowing an accurate classification after only two shots.The results demonstrate that different approaches must be employed depending on the paint color to achieve high classification accuracy with fewer shot numbers.
基金surpported by the National Natural Science Foundation of China(No.52206222,No.22227901)Aero Engine and Gas Turbine Basic Science Centre Project(P2023-B-V-002-001).
文摘The measurement of the combustion characteristics of a single biomass particle is essential for studying massive biofuel energy conversion process;however,it is challenging due to the small physical scale of the biomass particle flame.In this work,we report an investigation of the combustion behavior of single lignin and single cellulose particle through CO_(2)absorption spectroscopy and high-speed photography.The biomass samples are prepared with an initial diameter of about 1.0 mm and are ignited on a heating plate placed inside a multi-pass absorption cell.The shape and size transformation of single biomass particle are recorded through high-speed photography,and the combustion temperature and CO_(2)column densities are measured through laser absorption spectroscopy at 4.172µm.We find that the maximum combustion temperatures are 1662±38 K and 1569±26 K for lignin and cellulose particle,respectively.Besides,we find that CO_(2)generation precedes the generation of visible volatile flame for cellulose particle.While for lignin particle,the CO_(2)generation is found to be almost at the same time as its volatile combustion stage begins.The measurement technique and results presented in this work are of practical interest for biomass combustion studies and arc meaningful for the development of biomass thermal conversion mode.
基金partly financially supported by the 100 Talents Program of CASthe National Basic Research Program of China(Grant No.2011CB808101)the National Natural Science Foundation of China(Grant No.61475169,61221064)
文摘We report the experimental demonstration of transform-limited sub-6 fs pulses at an optimal central wavelength by a tunable noncollinear optical parametric amplification(NOPA) source. Meanwhile, a white light continuum in the near-infrared(NIR) range from 900 to 1100 nm is also successfully generated by focusing the unconverted800 nm beam during NOPA generation on a sapphire rod. Both visible-pump/visible-probe and visible-pump/NIR-probe experiments are realized using the same laser system. As examples, ultrafast photo-induced exciton dynamics inside two kinds of materials are investigated by the visible-pump/visible-probe and visible-pump/NIR-probe spectroscopy, respectively.
文摘In this work, Laser Induced Breakdown Spectroscopy (LIBS) was used to determine the constituent of Gum Arabic (<i><span>Acacia nilotica</span></i><span>) collected from five different locations in Sudan. Gum samples were irradiated with 80 mJ pulse energy of Nd-YAG laser (1064 nm) and Atomic spectra Database was used for the spectral analysis of the plasma emitted from these samples. It was found that the samples contain the elements C, O, H, S, N, P, Na, Mg, Ca, Fe, Cr, Mn, Co with different amounts. Some elements like (Ti, Br, Ar, Th, Kr, Sc and Pr) are recorded here for the first time.</span>
文摘High-resolution atomic-beam laser spectroscopy has been performed to study Stark effect of Ba atom. Stark spectra have been observed at various electric fields for Ba highly excited states. The scalar polarizability of the transition from 6s5d3D2 to 5d6p3F3 at 728.0 nm and the tensor polarizability of the 3F3 level have been determined for the first time, to be αs = -89.8 (12) kHz/(kV/cm)2 and αt = -133.7 (20) kHz/(kV/cm)2, respectively.
文摘This study investigates the optical properties of sesame oil from traditional and industrial sources using a custom-designed semiconductor laser spectrometer, UV-Vis spectroscopy, and FTIR spectroscopy. Six samples were collected from traditional presses and factories in Khartoum State and White Nile State. The spectrometer, constructed with a 680 nm semiconductor laser and various resistor values, measured the absorbance of sesame oil samples. UV-Vis spectroscopy identified absorbance peaks at 670 nm and 417 nm, corresponding to chlorophyll a and b. FTIR analysis showed nearly identical spectra among the samples, indicating similar chemical compositions. Laser spectrometer analysis revealed specific absorbance values for each sample. The results highlight the feasibility of using a 680 nm semiconductor laser for analyzing sesame oil, providing a cost-effective alternative to other wavelengths. This study demonstrates the potential of integrating traditional methods with modern spectroscopic techniques for the quality assessment of sesame oil.
基金supported by the National High Technology Research and Development Program of China (No.2006AA09Z243)the Natural Science Foundation of Shandong Province (No.Y2006A26)
文摘The laser induced breakdown spectroscopy(LIBS) is an element analysis technique with the advantages of real time detection,simultaneous multi-element identification,and in-situ and stand-off capacities.To evaluate its potential of ocean applications,in this paper,the time resolved laser-induced breakdown spectroscopy for calcium concentration detection in water is investigated.With the optimum experimental parameters,the plasma emission lifetime is determined to be about 500 ns with 532 nm laser excitation,and 1000 ns with 1064 nm laser excitation.The lowest detection concentration of 50 ppm is achieved for calcium detection in CaCl2 water solution using the 532 nm LIBS.Even better detection sensitivity is achieved using the 1064 nm LIBS,and the resulted lowest detection concentration of calcium is 25 ppm.The results suggest that it is feasible to develop LIBS as an on-line sensor for metal element monitoring in the sea.
文摘Spatial confinement has great potential for Laser Induced Breakdown Spectroscopy (LIBS) instruments after it has been proven that it has the ability to enhance the LIBS signal strength and repeatability. In order to achieve in-situ measurement of heavy metals in farmland soils by LIBS, a hemispherical spatial confinement device is designed and used to collect plasma spectra, in which the optical fibers directly collect the breakdown spectroscopy of the soil samples. This device could effectively increase the stability of the spectrum intensity of soil. It also has other advantages, such as ease of installation, and its small and compact size. The relationship between the spectrum intensity and the laser pulse energy is studied for this device. It is found that the breakdown threshold is 160 cm-2, and when the laser fluence increases to 250 J/cm2, the spectrum intensity reaches its maximum. Four different kinds of laser pulse energy were set up and in each case the limits of detection of Cd, Cu, Ni, Pb and Zn were calculated. The results show that when the laser pulse fluence was 2.12 GW/cm2, we obtained the smallest limits of detection of these heavy metals, which are all under 10 mg/kg. This device can satisfy the needs of heavy metal in-situ detection, and in the next step it will be integrated into a portable LIBS instrument.
基金supported by National Natural Science Foundation of China(No.61178022)the Natural Science Foundation of Jilin Province,China(No.201215132)the Doctoral Program of High Education of China(No.20112216120006)
文摘In this paper the spectral enhancement of laser-induced breakdown spectroscopy (LIBS) for copper plasma in the presence of a magnetic field is investigated and the temporal- and spatial-resolved plasma emission spectra are analyzed. Experimental results show that the copper plasma atomic and ion spectra have been enhanced in the presence of the external magnetic field. In addition, the Cu I 521.82 nm spectral intensity evolution with delay time appears to have a double peak around the delay time of 2 μs, but that of Cu II 507.57 nm has a sharp decrease because of the electron-atom three body recombination process. The plasma temperature with magnetic confinement is lower than that of the case in the absence of magnetic fields. Finally, the spectral enhancement mechanisms of laser induced breakdown spectroscopy with magnetic confinement are analyzed.
文摘Exhaust gas temperature is an important factor in NOx, THC and PM emissions of engines. Especially 2D temperature and concentration distribution plays an important role for the engine efficiency. A thermocouple is intrinsically a point temperature measurement method and noncontact 2D temperature distribution cannot be attained by thermocouples. Recently, as a measurement technique with high sensitivity and high response, laser diagnostics has been developed and applied to the actual engine combustions. With these engineering developments, transient phenomena such as start-ups and load changes in engines have been gradually elucidated in various conditions. In this study, the theoretical and experimental research has been conducted in order to develop the noncontact and fast response 2D temperature and concentration distribution measurement method. The method is based on a Computed Tomography (CT) method using absorption spectra of water vapor at 1388 nm. It has been demonstrated that the method has been successfully applied to engine exhausts to measure 2D temperature distributions.
文摘Aqueous ruthenium was detected in real-time under ambient conditions using microwaveassisted laser-induced breakdown spectroscopy(MW-LIBS).A 10 mJ laser energy and 750 W microwave power were directed at an open liquid jet sample of ruthenium.It was observed that,for liquid flow,the coupling efficiency between the microwave and the laser-induced plasma was limited to 43%.The improvement in the ruthenium’s signal-to-noise ratio with MW-LIBS,with respect to LIBS,was 76-fold.Based on MW-LIBS,the limit of detection for aqueous ruthenium was determined to be 957±84 ppb.
基金supported by the National Natural Science Foundation of China(Grant Nos.11335004,11722541,11675039,and 11747153)the Important National Science and Technology Specific Project,China(Grant No.2011ZX02403-001)
文摘Densities of Ar metastable states 1s5 and 1s3 are measured by using the tunable diode laser absorption spectroscopy(TDLAS) in Ar and Ar/O2 mixture dual-frequency capacitively coupled plasma(DF-CCP). We investigate the effects of high-frequency(HF, 60 MHz) power, low-frequency(LF, 2 MHz) power, and working pressure on the density of Ar metastable states for three different gas components(0%, 5%, and 10% oxygen mixed in argon). The dependence of Ar metastable state density on the oxygen content is also studied at different working pressures. It is found that densities of Ar metastable states in discharges with different gas components exhibit different behaviors as HF power increases. With the increase of HF power, the metastable density increases rapidly at the initial stage, and then tends to be saturated at a higher HF power. With a small fraction(5% or 10%) of oxygen added in argon plasma, a similar change of the Ar metastable density with HF power can be observed, but the metastable density is saturated at a higher HF power than in the pure argon discharge. In the DF-CCP, the metastable density is found to be higher than in a single frequency discharge, and has weak dependence on LF power. As working pressure increases, the metastable state density first increases and then decreases,and the pressure value, at which the density maximum occurs, decreases with oxygen content increasing. Besides, adding a small fraction of oxygen into argon plasma will significantly dwindle the metastable state density as a result of quenching loss by oxygen molecules.
基金supported by the National Key R&D Program of China(No.2017YFC1200400)the Development Fund of Institute of Fluid Physics,China Academy of Engineering Physics(No.SFZ20150302)。
文摘A metal-assisted method is proposed for the evaluation of gases’molecular abundance ratio in fiber-optic laser-induced breakdown spectroscopy(FO-LIBS).This method can reduce the laser ablation energy and make gas composition identification possible.The principle comes from the collision between the detected gases and the plasma produced by the laser ablation of the metal substrate.The interparticle collision in the plasma plume leads to gas molecules dissociating and sparking,which can be used to determine the gas composition.The quantitative relationship between spectral line intensity and molecular abundance ratio was developed over a large molecular abundance ratio range.The influence of laser ablation energy and substrate material on gas quantitative calibration measurement is also analyzed.The proposed metal-assisted method makes the measurement of gases’molecular abundance ratios possible with an FO-LIBS system.
文摘At present, heavy metal pollution in food occurs frequently, which requires a novel method for rapid detection. Laser induced breakdown spectroscopy (LIBS) is a new technique for rapid and environmental friendly detection, but it lacks high sensitivity and stability which restrict its development. In this study, Cr-polluted infant milk powder was used as experimental material to explore the feasibility of the application of LIBS technique in food safety detection. Aiming at improving the precision and accuracy of Cr detection by LIBS technique, LIBS spectra of samples were collected by a spectrometer with an intensified charge-cou- pled device (ICCD) using three gratings with different resolutions to comprehensively compare and analyze the stability, sensitivity and quantitative analysis accura- cy of LIBS detection. The results showed that average relative standard deviation (RSD) of LIBS spectral intensity was below 10%, indicating good stability. LIBS signals were collected by three gratings for quantitative analysis, and the results demonstrated that the linear correlation coefficient R2 of fitting curves was 0. 248 87, 0.903 12 and 0.992 81, respectively; the relative errors between actual and predicted concentrations were 38.23%, 8.84% and 7.43%, respectively, indicating that gratings with higher resolutions could lead to higher linear correlation coefficient and better detection accuracy. According to the results, high-resolu- tion spectrometer could significantly improve the accuracy of LIBS detection of Cr concentration in milk powder, suggesting that it is feasible to detect heavy metals in food by LIBS technique with the improvement of core device performance.