Fiber optic sensing technology,with its low transmission loss,wide bandwidth,and broad dynamic range,offers significant advantages for high-sensitivity measurements.In this study,a multi-band soliton modulation system...Fiber optic sensing technology,with its low transmission loss,wide bandwidth,and broad dynamic range,offers significant advantages for high-sensitivity measurements.In this study,a multi-band soliton modulation system for stress sensing is proposed,utilizing Ti_(3)C_(2)T_(x)to generate ultrashort pulses.By applying stress to microfibers,dichromatic periodic multisoliton mode-locking at 1530 nm and 1555.2 nm is achieved.Vibrational mechanical stress further modulates cross-phase interactions between solitons,inducing higher-order bound solitons with small-amplitude oscillations.These dynamic processes reveal complex nonlinear optical behaviors and enhance sensing capabilities.Additionally,the feasibility of stable mode-locking of Ti_(3)C_(2)T_(x)in a 1µm multimode cavity is analyzed using the multimode nonlinear Schrodinger equation,and multisoliton states are experimentally demonstrated by integrating a 1µm narrow-linewidth ultrafast multimode laser with a stressed microfiber.展开更多
Spin-momentum locking is widely regarded as an inherent property of evanescent waves,where the transverse spin angular momentum is intrinsically tied to the wave's polarization.This principle is well established i...Spin-momentum locking is widely regarded as an inherent property of evanescent waves,where the transverse spin angular momentum is intrinsically tied to the wave's polarization.This principle is well established in systems such as surface plasmon polaritons,surface elastic waves,and other evanescent modes.Here,we theoretically unveil an anomalous breakdown of spin-momentum locking in evanescent electromagnetic waves at a metalgyromagnetic interface.We show that the hybrid polarization of the field induces two successive reversals of transverse spin near the interface—directly violating the conventional locking between spin and momentum.As a result,identical chiral sources placed at different heights above the interface excite evanescent waves propagating in opposite directions,defying standard expectations.This discovery challenges the presumed universality of spin-momentum locking and opens new degrees of freedom for controlling wave propagation in photonic and plasmonic systems.展开更多
As a major fault in the northeastern Qinghai-Xizang Plateau,the Haiyuan fault zone is important for understanding the regional deformation.Aiming at the differences in the slip rate and locking degree obtained from di...As a major fault in the northeastern Qinghai-Xizang Plateau,the Haiyuan fault zone is important for understanding the regional deformation.Aiming at the differences in the slip rate and locking degree obtained from different studies,this study constructs a refined block model(including Qilian,Alxa,Ordos,Xining,Haiyuan,and Lanzhou blocks)and uses the grid search and simulated annealing methods to invert GPS data for slip rate and locking degree of the Haiyuan fault zone.The results are as follows:(1)The sinistral slip rates in the western,middle,and eastern segments are 4.93-5.22 mm/a,1.52-4.94 mm/a,and 0.43-1.18 mm/a,decreasing eastward on the whole,while the compression rates are 0.45-1.26 mm/a,0.58-2.62 mm/a,and3.52-4.48 mm/a,increasing eastward on the whole.(2)The locking depth of the western segment increases from about 5 km to about 20 km eastward;the middle segment decreases and then increases eastward;the eastern segment concentrates at about 20 km(PHI is about 0.86).(3)The slip deficit is relatively higher in the Lenglongling,Jinqianghe,Maomaoshan,and Liupanshan faults(averaging about 3.42 mm/a,4.16 mm/a,4.23 mm/a,and 3.43 mm/a within 20 km).(4)The Qilian,Alxa,Xining,Lanzhou,and Haiyuan blocks rotate clockwise,while the Ordos block rotates counterclockwise.Additionally,by comparing different block models,the Haiyuan block should be considered independently.The Haiyuan fault zone adjusts surrounding block movements and uplifts Liupanshan mountain tectonically.The results can provide important references for understanding the regional earthquake risk and deformation mechanism.展开更多
A cavity magnonic oscillator uses the coupling of a planar transmission line oscillator(cavity) and spin excitations(magnons) in a ferrimagnetic material to achieve superior frequency stability and reduced phase noise...A cavity magnonic oscillator uses the coupling of a planar transmission line oscillator(cavity) and spin excitations(magnons) in a ferrimagnetic material to achieve superior frequency stability and reduced phase noise. Like many low phase noise oscillators, a cavity magnonic oscillator faces the challenge that its narrow resonance profile is not well suited for injection locking amplification. This work presents an improved design for such an oscillator configured as an injection locking amplifier(ILA) with an extended lock range. The proposed design features a two-stage architecture, consisting of a pre-amplification oscillator and a cavity magnonic oscillator, separated by an isolator to prevent backward locking.By optimizing the circuit parameters of each stage, the proposed design achieved an order of magnitude increase in lock range, when compared to its predecessors, all while preserving the phase noise quality of the input, making it well-suited for narrowband, sensitive signal amplification. Furthermore, this work provides a method for using oscillators with high spectral purity as injection locking amplifiers.展开更多
In 2018,Baige,Xizang,witnessed two consecutive large-scale landslides,causing significant damage and drawing widespread attention.From March 2011 to February 2018,the Baige landslide exhibited a 50-m displacement with...In 2018,Baige,Xizang,witnessed two consecutive large-scale landslides,causing significant damage and drawing widespread attention.From March 2011 to February 2018,the Baige landslide exhibited a 50-m displacement without complete failure,culminating in a collapse in October 2018.The mechanisms behind its resistance to failure despite substantial deformation and the influence of the complex geo-structure within the tectonic mélange belt remain unclear.To address these questions,this study utilized a multidisciplinary approach,integrating on-site geological field mapping,surface deformation monitoring,multielectrode resistivity method,and deep displacement analysis.The aim was to evaluate the impact of the intricate geo-structure within the tectonic mélange belt on the Baige landslide events.Findings reveal that the landslide's geo-structure consists of structurally fractured,mesh-like rock masses,including heterogeneous lenticular rock masses and intermittent brittle shear zones distributed around the lens-shaped rock masses.The study underscores that the inhomogeneous and weakly deformed lenticular rock masses function as natural locked segments,governing the stability of the Baige landslide.Specifically,the relatively intact and hard granodiorite porphyry play a crucial role in locking the landslide's deformation.Deep displacement analysis indicates that the brittle shear zones act as the sliding surfaces.The progressive destruction of the locked segments and the gradual penetration of brittle shear zones,driven by gravitational potential energy,contribute to the landslide occurrence.This research provides critical insights into the formation mechanisms of large-scale landslides within tectonic mélange belts.展开更多
This paper proposes a new upper-limb exoskeleton to reduce worker physical strain.The proposed design is based on a novel PRRRP(P-Prismatic;R-Revolute)kinematic chain with 5 passive Degrees of Freedom(DoF).Utilizing a...This paper proposes a new upper-limb exoskeleton to reduce worker physical strain.The proposed design is based on a novel PRRRP(P-Prismatic;R-Revolute)kinematic chain with 5 passive Degrees of Freedom(DoF).Utilizing a magnetic spring,the proposed mechanism includes a specially designed locking mechanism that maintains any desired task posture.The proposed exoskeleton incorporates a balancing mechanism to alleviate discomfort and spinal torsional effects also helping in limb weight relief.This paper reports specific models and simulations to demonstrate the feasibility and effectiveness of the proposed design.An experimental characterization is performed to validate the performance of the mechanism in terms of forces and physical strain during a specific application consisting of ceiling-surface drilling tasks.The obtained results preliminarily validate the engineering feasibility and effectiveness of the proposed exoskeleton in the intended operation task thereby requiring the user to exert significantly less force than when not wearing it.展开更多
Mode locking can be effectively achieved by using the thermo-optic effects in the whispering gallery mode(WGM)optical microcavity,without the help of external equipment.Therefore,it has the advantages of small size,lo...Mode locking can be effectively achieved by using the thermo-optic effects in the whispering gallery mode(WGM)optical microcavity,without the help of external equipment.Therefore,it has the advantages of small size,low integration costs,and self-locking,which shows great potential for application.However,the conventional single-channel microcavity thermal-locking method that relies solely on internal thermal balance will inevitably be disturbed by the external environment.This limitation affects the locking time and stability.Therefore,in this paper,we propose a new method for closed-loop thermal locking of a dual-channel microcavity.The thermal locking of the signal laser and the thermal regulation of the control laser are carried out respectively by synchronously drawing a dual-path tapered fiber.The theoretical model of the thermal dynamics of the dual-channel microcavity system is established,and the influence of the control-laser power on the thermal locking of the signal laser is confirmed.The deviation between the locking voltage of the signal laser and the set point value is used as a closed-loop feedback parameter to achieve long-term and highly stable mode locking of the signal laser.The results show that in the 2.63 h thermal-locking test,the locking stability is an order of magnitude higher than that of the single tapered fiber.This solution addresses the issue of thermal locking being disrupted by the external environment,and offers new possibilities for important applications such as spectroscopy and micro-optical sensor devices.展开更多
According to the United Nations,a moderately aging society refers to a country where those aged 65 and above exceed 14%of the total population.Data released by the Ministry of Civil Affairs showed that there were 296....According to the United Nations,a moderately aging society refers to a country where those aged 65 and above exceed 14%of the total population.Data released by the Ministry of Civil Affairs showed that there were 296.97 million people aged 60 and above in China by the end of 2023,accounting for 21.1%of the total population.Among them,216.76 million were aged 65 and above,making up 15.4%of the total population.This indicates that China has officially crossed the threshold into a moderately aging society.展开更多
Independent living and housing stability are core principles of the psychiatric recovery process.Only when basic needs such as safe,affordable and permanent housing are met can individuals with serious mental illnesse...Independent living and housing stability are core principles of the psychiatric recovery process.Only when basic needs such as safe,affordable and permanent housing are met can individuals with serious mental illnesses(SMI)reintegrate into their community,consistently engage with mental health services and begin(or restart)recovery.'Yet,post-discharged individuals with SMI and their psychiatric care providers often grapple with where to go after discharge from psychiatric hospitalisation.This question is particularly central in safety-net hospitals serving people affected by severe health disparities with myriad deficits in social determinants of health(SDoH).In this commentary,we aim to shed light on post-discharge challenges related to housing often encountered by safety-net psychiatric hospitals and propose ways to address them.展开更多
The optoelectronic oscillator(OEO)is a typical time-delay system with rich nonlinear dynamical characteristics.Most of the previous research on OEOs has been focused on analyzing the properties of OEOs with a long tim...The optoelectronic oscillator(OEO)is a typical time-delay system with rich nonlinear dynamical characteristics.Most of the previous research on OEOs has been focused on analyzing the properties of OEOs with a long time delay,which makes it difficult to realize mode locking without additional phaselocking mechanisms.We have achieved,for the first time to our knowledge,a self-mode-locking OEO and generated stable microwave frequency combs by analyzing the characteristics of OEOs with an ultrashort time scale.In the experiment,the self-mode-locking OEOs with fundamental mode,second-order harmonic,and sixth-order harmonic were realized by adjusting the system parameters,all of which produced uniform square wave signals with tunable duty cycles,steep rising and falling edges,and periods of less than 20 ns.The self-fundamental-mode-locking OEOs with different time delays were also implemented and experimentally realized.Furthermore,the experiment revealed the self-hybrid mode-locking OEO,which is the coexistence and synchronization of the three measured self-locking modes in one OEO cavity,demonstrating the complex nonlinear dynamical behaviors of the OEO system and enabling the generation of periodic nonuniform hybrid square wave signals.The realization of the self-mode-locking OEO and the generation of flexible and stable square wave signals at ultrashort time scales enrich the study of OEO nonlinear dynamics in the realm of complex microwave waveform generation,offering promising applications in areas such as atomic clocks,radars,communications,and optoelectronic neural networks.展开更多
The widespread applications of single-cell technologies have generated a large amount of single-cell data,resulting in a growing need for single-cell data analysis and interpretation methods.While methods such as mach...The widespread applications of single-cell technologies have generated a large amount of single-cell data,resulting in a growing need for single-cell data analysis and interpretation methods.While methods such as machine learning allow for single-cell data analysis,they cannot interpret the data very well.展开更多
Background: Fractures of humeral shaft in adults are common injuries. Humeral shafts non-union either from late presentation after initial treatment by traditional bone setters or failed non-operative orthodox care is...Background: Fractures of humeral shaft in adults are common injuries. Humeral shafts non-union either from late presentation after initial treatment by traditional bone setters or failed non-operative orthodox care is a major problem in this part of the world. This non-union is a major treatment challenge with increased cost of care and morbidity in this part of the world. Humeral shaft non-union can be treated with locked intra-medullary nailing (LIMN) or dynamic compression plating (DCP). Study on comparison of these methods of fixation in this part of the world is scarce in literature search, hence the reason for this study. Objective: The objectives of this study are: (1) to compare early clinical outcome following fixation of humeral shaft fracture nonunion with DCP versus LIMN;(2) to compare the time of radiologic fracture union of DCP with LIMN;(3) to compare complications following fixation of humeral shaft fracture nonunion with DCP versus LIMN. Patients and Methods: This was a randomized control study done for 2 years in which fifty adult patients with humeral shaft non-union were recruited. The patients were grouped into 2 (P = DCP & N = LIMN). Forty five of the patients completed the follow up periods of the study and then analyzed. The P group had ORIF with DCP while the N group had ORIF with LIMN. Both groups had grafting with cancellous bones. Each patient was followed up for a period of 6 months at the time which radiographic union is expected. Any patient without clinical and/or radiographic evidence of union after six months of surgery was diagnosed as having recurrent non-union. The data generated was analyzed using SPSS Version 23. The results were presented in charts and tables. The paired t-test was used while considering p value Result: Forty five patients completed follow up. There was a male preponderance (4:1), right humerus predominated (3:2). Motor vehicular accidents were the commonest cause of the fractures (62%). Most non-union fractures occurred at the level of the middle 3<sup>rd</sup> of the humeral shaft (60%). Failed TBS treatment was the commonest indication for the osteosynthesis (71%). More patients had plating (53%) compared to 47% who had LIMN. Most patients (93.4%) had union between 3 to 6 months irrespective of fixation type with no significant statistical difference between the union rate of DCP and LIMN (p value 0.06) with similar functional outcome and complication rates irrespective of the type of fixation. Conclusion: This study showed that the success rates in term of fracture union, outcome functional grades and complication rates were not directly dependent on the types of the fixation: plating or locked intra-medullary nailing.展开更多
An 8-noded locking-free degenerated isoparametric shell element is presented. A revised interpolation for shear strain terms was constructed in natural co-ordinate system such that all necessary modes (translation, ro...An 8-noded locking-free degenerated isoparametric shell element is presented. A revised interpolation for shear strain terms was constructed in natural co-ordinate system such that all necessary modes (translation, rotation and constant curvature) are preserved, which can be used to eliminate shear locking. A revised interpolation for membrane strains was produced in the local Cartesian co-ordinate system to overcome membrane locking behavior. The new 8-noded element has the proper rank, with the requisite number of zero eigenvalues each associated with a rigid mode. The element does not exhibit membrane or shear locking for large span-thickness ratio. The element does not form element mechanisms or extra spurious zero energy modes. Therefore, it can be used for both thin and thick shells.展开更多
The distal interlocking is regarded as an inherent part of the antegrade humeral nailing technique. Traditionally the distal locking of intramedullary humeral nails is achieved using a freehand technique. The humerus ...The distal interlocking is regarded as an inherent part of the antegrade humeral nailing technique. Traditionally the distal locking of intramedullary humeral nails is achieved using a freehand technique. The humerus nailing locking options in the conventional nailing systems are placed in the anterior-posterior and lateral-medial directions. It exposes both the patient and surgeon to radiation, is time consuming, and has a potential risk of damaging neurovascular structures, especially the radial and lateral cutaneous nerve when the anterior-posterior and lateral-medial locking constructs are used. We aim to present a technical tip to ease the distal locking procedure and avoid the possible neurovascular complications with the existing nailing systems.展开更多
Background: Since we are very successful in the operation of hallux valgus using a transverse sub-capital osteotomy fixated with an intramedullary angle-stable locking plate, and a tailors bunion is understood as a re...Background: Since we are very successful in the operation of hallux valgus using a transverse sub-capital osteotomy fixated with an intramedullary angle-stable locking plate, and a tailors bunion is understood as a reversed hallux valgus, we have applied the operation also for such indication. Method: The osteotomy was carried out at a straight V. metatarsal subcapitally, and in case of an outwardly curved V. metatarsal at the bending location. The intramedullary plates are available in different designs and the plate and screws disappear completely in the bone, so the soft tissues are not disturbed. The head of the plate is either straight or curved in order to shift the distal fragment sufficiently. Results: 26 patients were operated within a period of 5 years (2008-2012). 21 patients were followed up after an average of 34.4 months. The IM angle IV/V could be improved by an average of 11.76 to an average of 4.10. This is a highliy significant pre- to postoperative difference of 7.66 (t = 15.07, p < 0.001). The AOFAS score was improved by an average of 42.24 points from 55.76 points preoperatively to 98.00 points postoperative. There was no pseudo-arthrosis and no wound healing impairment. All patients were either satisfied or very satisfied with the surgery. Conclusion: This method does not have the disadvantages of the other common operations of the Tailors bunion and is applied now as a standard method in this deformity.展开更多
A low-thermal-noise,small-sized,monolithic crystalline whispering-gallery-mode cavity can achieve a compact laser frequency locking system.In this study,we propose generating a Fano resonance spectrum within the cryst...A low-thermal-noise,small-sized,monolithic crystalline whispering-gallery-mode cavity can achieve a compact laser frequency locking system.In this study,we propose generating a Fano resonance spectrum within the crystalline cavity to achieve frequency locking without the need for traditional modulation techniques,aiming to further simplify the locking system.By coupling a prism with the crystalline cavity,we generate a Fano transmission spectrum to serve as the error signal for laser frequency locking.Experimental results show that our method achieves a level of noise suppression comparable to the classical Pound-Drever-Hall technique,reducing laser frequency noise to near the thermal noise limit of the crystalline cavity.It enables us to suppress the laser frequency noise to below 1 Hz^(2)∕Hz in the offset frequency range of 103-105Hz and achieve a minimum noise of0.2 Hz^(2)∕Hz.We also analyzed various unique optical noises in the Fano locking technique and found that the primary factor limiting laser frequency noise in this work is still the inherent thermal noise of the crystalline cavity.Our results indicate that the proposed Fano locking technique has significant potential to simplify laser locking systems,enhance stability,and reduce overall power consumption and cost.展开更多
AIM To compare the outcomes of displaced distal radius fractures treated with volar locking plates and with immediate postoperative mobilisation with the outcomes of these fractures treated with modalities that necess...AIM To compare the outcomes of displaced distal radius fractures treated with volar locking plates and with immediate postoperative mobilisation with the outcomes of these fractures treated with modalities that necessitate 6 wk wrist immobilisation.METHODS A prospective,randomised controlled single-centre trial was conducted with 56 patients who had a displaced radius fracture were randomised to treatment either with a volar locking plate(n=29),or another treatment modality(n=27;cast immobilisation with or without wires or external fixator).Outcomes were measured at 12 wk.Functional outcome scores measured were the Patient-Rated Wrist Evaluation(PRWE)Score;Disabilities of the Arm,Shoulder and Hand and activities of daily living(ADLs).Clinical outcomes were wrist range of motion and grip strength.Radiographic parameters were volar inclination and ulnar variance.RESULTS Patients in the volar locking plate group had significantly better PRWE scores,ADL scores,grip strength and range of extension at three months compared with the control group.All radiological parameters were significantly better in the volar locking plate group at 3 mo.CONCLUSION The present study suggests that volar locking plates produced significantly better functional and clinical outcomes at 3 mo compared with other treatment modalities.Anatomical reduction was significantly more likely to be preserved in the plating group.Level of evidence:Ⅱ.展开更多
Complex tibial plateau fractures can seriously affect quality of life and physical and mental health of patients.The anatomical relationship between the proximal tibial bone and soft tissue is complex,resulting in dif...Complex tibial plateau fractures can seriously affect quality of life and physical and mental health of patients.The anatomical relationship between the proximal tibial bone and soft tissue is complex,resulting in different types of tibial plateau fractures.Violent trauma can lead to displaced fracture,serious soft tissue injury,and potentially,dislocation of the knee joint.Therefore,tibial plateau fractures are extremely unstable.AIM To assess the use of locking compression plate(LCP)+T-type steel plate for postoperative weight bearing and functional recovery of complex tibial plateau fractures.METHODS Ninety-seven patients with complex tibial plateau fractures who underwent surgery at our hospital were selected for retrospective study.Forty-nine patients had been treated with LCP+T-type steel plate limited internal fixation(study group),and 48 patients with bilateral ordinary steel plate support(control group).The operation process index,postoperative rehabilitation related index,Rasmussen score of the knee joint,tibial plateau varus angle(TPA),tibial plateau retroversion angle(PA),and surgical complications of the two groups were compared.RESULTS The operation time and intraoperative bone graft volume in the study group were lower than those in the control group(P<0.05).There were no significant differences in surgical bleeding,anterior external incision length,postoperative drainage,hospital stay duration,and fracture healing time between the groups(P>0.05).There was no significant difference in the TPA and PA angle between the groups immediately and 18 mo after surgery(P>0.05).At 12 mo after surgery,the Rasmussen scale score was higher in the study group than in the control group(P<0.05).There was no significant difference in the Rasmussen scale score at 18 mo after surgery,and the radiology score at 12 and 18 mo after surgery,between the two groups(P>0.05).The postoperative complication rate in the study group(3.77%)was lower than that in the control group(15.09%;P<0.05).CONCLUSION LCP+T-type steel plate internal fixation has advantages in terms of minimizing trauma and enabling early postoperative functional exercise,promoting functional recovery and lower limb weight-bearing,and reducing postoperative complications.展开更多
Contact nonlinear theory was researched. Contact problem was transformed into optimization problem containing Lagrange multiplier, and unsymmetrical stiffness matrix was transformed into symmetrical stiffness matrix. ...Contact nonlinear theory was researched. Contact problem was transformed into optimization problem containing Lagrange multiplier, and unsymmetrical stiffness matrix was transformed into symmetrical stiffness matrix. A finite element analysis (FEA) model defining more than 300 contact pairs for long nut-short screw locking mechanism of a large-scale vertical gear-rack typed ship-lift was built. Using augmented Lagrange method and symmetry algorithm of contact element stiffness, the FEA model was analyzed, and the contact stress of contact interfaces and the von Mises stress of key parts were obtained. The results show that the design of the locking mechanism meets the requirement of engineering, and this method is effective for solving large stole nonlinear contact pairs.展开更多
基金supported by the National Natural Science Foundation of China(Grant Nos.12275240,12261131495,and 12475008)the Natural Science Foundation of Zhejiang Province(Grant No.LY24A050002).
文摘Fiber optic sensing technology,with its low transmission loss,wide bandwidth,and broad dynamic range,offers significant advantages for high-sensitivity measurements.In this study,a multi-band soliton modulation system for stress sensing is proposed,utilizing Ti_(3)C_(2)T_(x)to generate ultrashort pulses.By applying stress to microfibers,dichromatic periodic multisoliton mode-locking at 1530 nm and 1555.2 nm is achieved.Vibrational mechanical stress further modulates cross-phase interactions between solitons,inducing higher-order bound solitons with small-amplitude oscillations.These dynamic processes reveal complex nonlinear optical behaviors and enhance sensing capabilities.Additionally,the feasibility of stable mode-locking of Ti_(3)C_(2)T_(x)in a 1µm multimode cavity is analyzed using the multimode nonlinear Schrodinger equation,and multisoliton states are experimentally demonstrated by integrating a 1µm narrow-linewidth ultrafast multimode laser with a stressed microfiber.
基金supported by the National Natural Science Foundation of China(Grant Nos.12434016 and 12474380)Science and Technology Project of Guangdong Province(Grant No.2020B0101-90001)+1 种基金the National Key Research and Development Program of China(Grant No.2023YFA1406900)the Natural Science Foundation of Guangdong Province(Grant No.2025A1515010714)。
文摘Spin-momentum locking is widely regarded as an inherent property of evanescent waves,where the transverse spin angular momentum is intrinsically tied to the wave's polarization.This principle is well established in systems such as surface plasmon polaritons,surface elastic waves,and other evanescent modes.Here,we theoretically unveil an anomalous breakdown of spin-momentum locking in evanescent electromagnetic waves at a metalgyromagnetic interface.We show that the hybrid polarization of the field induces two successive reversals of transverse spin near the interface—directly violating the conventional locking between spin and momentum.As a result,identical chiral sources placed at different heights above the interface excite evanescent waves propagating in opposite directions,defying standard expectations.This discovery challenges the presumed universality of spin-momentum locking and opens new degrees of freedom for controlling wave propagation in photonic and plasmonic systems.
基金supported by the National Natural Science Foundation of China(42474003,42074007)the Fundamental Research Funds for the Central Universities(2042023kfyq01)。
文摘As a major fault in the northeastern Qinghai-Xizang Plateau,the Haiyuan fault zone is important for understanding the regional deformation.Aiming at the differences in the slip rate and locking degree obtained from different studies,this study constructs a refined block model(including Qilian,Alxa,Ordos,Xining,Haiyuan,and Lanzhou blocks)and uses the grid search and simulated annealing methods to invert GPS data for slip rate and locking degree of the Haiyuan fault zone.The results are as follows:(1)The sinistral slip rates in the western,middle,and eastern segments are 4.93-5.22 mm/a,1.52-4.94 mm/a,and 0.43-1.18 mm/a,decreasing eastward on the whole,while the compression rates are 0.45-1.26 mm/a,0.58-2.62 mm/a,and3.52-4.48 mm/a,increasing eastward on the whole.(2)The locking depth of the western segment increases from about 5 km to about 20 km eastward;the middle segment decreases and then increases eastward;the eastern segment concentrates at about 20 km(PHI is about 0.86).(3)The slip deficit is relatively higher in the Lenglongling,Jinqianghe,Maomaoshan,and Liupanshan faults(averaging about 3.42 mm/a,4.16 mm/a,4.23 mm/a,and 3.43 mm/a within 20 km).(4)The Qilian,Alxa,Xining,Lanzhou,and Haiyuan blocks rotate clockwise,while the Ordos block rotates counterclockwise.Additionally,by comparing different block models,the Haiyuan block should be considered independently.The Haiyuan fault zone adjusts surrounding block movements and uplifts Liupanshan mountain tectonically.The results can provide important references for understanding the regional earthquake risk and deformation mechanism.
基金funded by NSERC Discovery Grants, NSERC Discovery Accelerator Supplements, Innovation Proof-of-Concept Grant of Research Manitoba, and Faculty of Science Research Innovation and Commercialization Grant of University of Manitoba (C.-M.H.)。
文摘A cavity magnonic oscillator uses the coupling of a planar transmission line oscillator(cavity) and spin excitations(magnons) in a ferrimagnetic material to achieve superior frequency stability and reduced phase noise. Like many low phase noise oscillators, a cavity magnonic oscillator faces the challenge that its narrow resonance profile is not well suited for injection locking amplification. This work presents an improved design for such an oscillator configured as an injection locking amplifier(ILA) with an extended lock range. The proposed design features a two-stage architecture, consisting of a pre-amplification oscillator and a cavity magnonic oscillator, separated by an isolator to prevent backward locking.By optimizing the circuit parameters of each stage, the proposed design achieved an order of magnitude increase in lock range, when compared to its predecessors, all while preserving the phase noise quality of the input, making it well-suited for narrowband, sensitive signal amplification. Furthermore, this work provides a method for using oscillators with high spectral purity as injection locking amplifiers.
基金supported by the National Major Scientific Instruments and Equipment Development Projects of China(No.41827808)the Major Program of the National Natural Science Foundation of China(No.42090055)Supported by Science and Technology Projects of Xizang Autonomous Region,China(No.XZ202402ZD0001)。
文摘In 2018,Baige,Xizang,witnessed two consecutive large-scale landslides,causing significant damage and drawing widespread attention.From March 2011 to February 2018,the Baige landslide exhibited a 50-m displacement without complete failure,culminating in a collapse in October 2018.The mechanisms behind its resistance to failure despite substantial deformation and the influence of the complex geo-structure within the tectonic mélange belt remain unclear.To address these questions,this study utilized a multidisciplinary approach,integrating on-site geological field mapping,surface deformation monitoring,multielectrode resistivity method,and deep displacement analysis.The aim was to evaluate the impact of the intricate geo-structure within the tectonic mélange belt on the Baige landslide events.Findings reveal that the landslide's geo-structure consists of structurally fractured,mesh-like rock masses,including heterogeneous lenticular rock masses and intermittent brittle shear zones distributed around the lens-shaped rock masses.The study underscores that the inhomogeneous and weakly deformed lenticular rock masses function as natural locked segments,governing the stability of the Baige landslide.Specifically,the relatively intact and hard granodiorite porphyry play a crucial role in locking the landslide's deformation.Deep displacement analysis indicates that the brittle shear zones act as the sliding surfaces.The progressive destruction of the locked segments and the gradual penetration of brittle shear zones,driven by gravitational potential energy,contribute to the landslide occurrence.This research provides critical insights into the formation mechanisms of large-scale landslides within tectonic mélange belts.
基金supported by the European Regional Development Fund and the Romanian Government through the Competitiveness Operational Programme 2014-2020project APOLLO,MySMIS code 155988,contract no.9/1.2.1-PTIap.2/23.02.2023.
文摘This paper proposes a new upper-limb exoskeleton to reduce worker physical strain.The proposed design is based on a novel PRRRP(P-Prismatic;R-Revolute)kinematic chain with 5 passive Degrees of Freedom(DoF).Utilizing a magnetic spring,the proposed mechanism includes a specially designed locking mechanism that maintains any desired task posture.The proposed exoskeleton incorporates a balancing mechanism to alleviate discomfort and spinal torsional effects also helping in limb weight relief.This paper reports specific models and simulations to demonstrate the feasibility and effectiveness of the proposed design.An experimental characterization is performed to validate the performance of the mechanism in terms of forces and physical strain during a specific application consisting of ceiling-surface drilling tasks.The obtained results preliminarily validate the engineering feasibility and effectiveness of the proposed exoskeleton in the intended operation task thereby requiring the user to exert significantly less force than when not wearing it.
基金Project supported by the National Key Research and Development Program of China(Grant No.2022YFB3203400)the National Natural Science Foundation of China(Grant Nos.U21A20141,62273314,and 51821003)+1 种基金the Fundamental Research Program of Shanxi Province(Grant No.202303021223001)Shanxi Province Key Laboratory of Quantum Sensing and Precision Measurement(Grant No.201905D121001)。
文摘Mode locking can be effectively achieved by using the thermo-optic effects in the whispering gallery mode(WGM)optical microcavity,without the help of external equipment.Therefore,it has the advantages of small size,low integration costs,and self-locking,which shows great potential for application.However,the conventional single-channel microcavity thermal-locking method that relies solely on internal thermal balance will inevitably be disturbed by the external environment.This limitation affects the locking time and stability.Therefore,in this paper,we propose a new method for closed-loop thermal locking of a dual-channel microcavity.The thermal locking of the signal laser and the thermal regulation of the control laser are carried out respectively by synchronously drawing a dual-path tapered fiber.The theoretical model of the thermal dynamics of the dual-channel microcavity system is established,and the influence of the control-laser power on the thermal locking of the signal laser is confirmed.The deviation between the locking voltage of the signal laser and the set point value is used as a closed-loop feedback parameter to achieve long-term and highly stable mode locking of the signal laser.The results show that in the 2.63 h thermal-locking test,the locking stability is an order of magnitude higher than that of the single tapered fiber.This solution addresses the issue of thermal locking being disrupted by the external environment,and offers new possibilities for important applications such as spectroscopy and micro-optical sensor devices.
文摘According to the United Nations,a moderately aging society refers to a country where those aged 65 and above exceed 14%of the total population.Data released by the Ministry of Civil Affairs showed that there were 296.97 million people aged 60 and above in China by the end of 2023,accounting for 21.1%of the total population.Among them,216.76 million were aged 65 and above,making up 15.4%of the total population.This indicates that China has officially crossed the threshold into a moderately aging society.
文摘Independent living and housing stability are core principles of the psychiatric recovery process.Only when basic needs such as safe,affordable and permanent housing are met can individuals with serious mental illnesses(SMI)reintegrate into their community,consistently engage with mental health services and begin(or restart)recovery.'Yet,post-discharged individuals with SMI and their psychiatric care providers often grapple with where to go after discharge from psychiatric hospitalisation.This question is particularly central in safety-net hospitals serving people affected by severe health disparities with myriad deficits in social determinants of health(SDoH).In this commentary,we aim to shed light on post-discharge challenges related to housing often encountered by safety-net psychiatric hospitals and propose ways to address them.
基金supported by the National Natural Science Foundation of China(Grant No.62301495)the Project of the National Key Laboratory of Microwave Photonics(Nanjing University of Aeronautics and Astronautics),Ministry of Education(Grant No.NJ20220007).
文摘The optoelectronic oscillator(OEO)is a typical time-delay system with rich nonlinear dynamical characteristics.Most of the previous research on OEOs has been focused on analyzing the properties of OEOs with a long time delay,which makes it difficult to realize mode locking without additional phaselocking mechanisms.We have achieved,for the first time to our knowledge,a self-mode-locking OEO and generated stable microwave frequency combs by analyzing the characteristics of OEOs with an ultrashort time scale.In the experiment,the self-mode-locking OEOs with fundamental mode,second-order harmonic,and sixth-order harmonic were realized by adjusting the system parameters,all of which produced uniform square wave signals with tunable duty cycles,steep rising and falling edges,and periods of less than 20 ns.The self-fundamental-mode-locking OEOs with different time delays were also implemented and experimentally realized.Furthermore,the experiment revealed the self-hybrid mode-locking OEO,which is the coexistence and synchronization of the three measured self-locking modes in one OEO cavity,demonstrating the complex nonlinear dynamical behaviors of the OEO system and enabling the generation of periodic nonuniform hybrid square wave signals.The realization of the self-mode-locking OEO and the generation of flexible and stable square wave signals at ultrashort time scales enrich the study of OEO nonlinear dynamics in the realm of complex microwave waveform generation,offering promising applications in areas such as atomic clocks,radars,communications,and optoelectronic neural networks.
文摘The widespread applications of single-cell technologies have generated a large amount of single-cell data,resulting in a growing need for single-cell data analysis and interpretation methods.While methods such as machine learning allow for single-cell data analysis,they cannot interpret the data very well.
文摘Background: Fractures of humeral shaft in adults are common injuries. Humeral shafts non-union either from late presentation after initial treatment by traditional bone setters or failed non-operative orthodox care is a major problem in this part of the world. This non-union is a major treatment challenge with increased cost of care and morbidity in this part of the world. Humeral shaft non-union can be treated with locked intra-medullary nailing (LIMN) or dynamic compression plating (DCP). Study on comparison of these methods of fixation in this part of the world is scarce in literature search, hence the reason for this study. Objective: The objectives of this study are: (1) to compare early clinical outcome following fixation of humeral shaft fracture nonunion with DCP versus LIMN;(2) to compare the time of radiologic fracture union of DCP with LIMN;(3) to compare complications following fixation of humeral shaft fracture nonunion with DCP versus LIMN. Patients and Methods: This was a randomized control study done for 2 years in which fifty adult patients with humeral shaft non-union were recruited. The patients were grouped into 2 (P = DCP & N = LIMN). Forty five of the patients completed the follow up periods of the study and then analyzed. The P group had ORIF with DCP while the N group had ORIF with LIMN. Both groups had grafting with cancellous bones. Each patient was followed up for a period of 6 months at the time which radiographic union is expected. Any patient without clinical and/or radiographic evidence of union after six months of surgery was diagnosed as having recurrent non-union. The data generated was analyzed using SPSS Version 23. The results were presented in charts and tables. The paired t-test was used while considering p value Result: Forty five patients completed follow up. There was a male preponderance (4:1), right humerus predominated (3:2). Motor vehicular accidents were the commonest cause of the fractures (62%). Most non-union fractures occurred at the level of the middle 3<sup>rd</sup> of the humeral shaft (60%). Failed TBS treatment was the commonest indication for the osteosynthesis (71%). More patients had plating (53%) compared to 47% who had LIMN. Most patients (93.4%) had union between 3 to 6 months irrespective of fixation type with no significant statistical difference between the union rate of DCP and LIMN (p value 0.06) with similar functional outcome and complication rates irrespective of the type of fixation. Conclusion: This study showed that the success rates in term of fracture union, outcome functional grades and complication rates were not directly dependent on the types of the fixation: plating or locked intra-medullary nailing.
文摘An 8-noded locking-free degenerated isoparametric shell element is presented. A revised interpolation for shear strain terms was constructed in natural co-ordinate system such that all necessary modes (translation, rotation and constant curvature) are preserved, which can be used to eliminate shear locking. A revised interpolation for membrane strains was produced in the local Cartesian co-ordinate system to overcome membrane locking behavior. The new 8-noded element has the proper rank, with the requisite number of zero eigenvalues each associated with a rigid mode. The element does not exhibit membrane or shear locking for large span-thickness ratio. The element does not form element mechanisms or extra spurious zero energy modes. Therefore, it can be used for both thin and thick shells.
文摘The distal interlocking is regarded as an inherent part of the antegrade humeral nailing technique. Traditionally the distal locking of intramedullary humeral nails is achieved using a freehand technique. The humerus nailing locking options in the conventional nailing systems are placed in the anterior-posterior and lateral-medial directions. It exposes both the patient and surgeon to radiation, is time consuming, and has a potential risk of damaging neurovascular structures, especially the radial and lateral cutaneous nerve when the anterior-posterior and lateral-medial locking constructs are used. We aim to present a technical tip to ease the distal locking procedure and avoid the possible neurovascular complications with the existing nailing systems.
文摘Background: Since we are very successful in the operation of hallux valgus using a transverse sub-capital osteotomy fixated with an intramedullary angle-stable locking plate, and a tailors bunion is understood as a reversed hallux valgus, we have applied the operation also for such indication. Method: The osteotomy was carried out at a straight V. metatarsal subcapitally, and in case of an outwardly curved V. metatarsal at the bending location. The intramedullary plates are available in different designs and the plate and screws disappear completely in the bone, so the soft tissues are not disturbed. The head of the plate is either straight or curved in order to shift the distal fragment sufficiently. Results: 26 patients were operated within a period of 5 years (2008-2012). 21 patients were followed up after an average of 34.4 months. The IM angle IV/V could be improved by an average of 11.76 to an average of 4.10. This is a highliy significant pre- to postoperative difference of 7.66 (t = 15.07, p < 0.001). The AOFAS score was improved by an average of 42.24 points from 55.76 points preoperatively to 98.00 points postoperative. There was no pseudo-arthrosis and no wound healing impairment. All patients were either satisfied or very satisfied with the surgery. Conclusion: This method does not have the disadvantages of the other common operations of the Tailors bunion and is applied now as a standard method in this deformity.
基金National Natural Science Foundation of China(62305136,62035007,61805112)。
文摘A low-thermal-noise,small-sized,monolithic crystalline whispering-gallery-mode cavity can achieve a compact laser frequency locking system.In this study,we propose generating a Fano resonance spectrum within the crystalline cavity to achieve frequency locking without the need for traditional modulation techniques,aiming to further simplify the locking system.By coupling a prism with the crystalline cavity,we generate a Fano transmission spectrum to serve as the error signal for laser frequency locking.Experimental results show that our method achieves a level of noise suppression comparable to the classical Pound-Drever-Hall technique,reducing laser frequency noise to near the thermal noise limit of the crystalline cavity.It enables us to suppress the laser frequency noise to below 1 Hz^(2)∕Hz in the offset frequency range of 103-105Hz and achieve a minimum noise of0.2 Hz^(2)∕Hz.We also analyzed various unique optical noises in the Fano locking technique and found that the primary factor limiting laser frequency noise in this work is still the inherent thermal noise of the crystalline cavity.Our results indicate that the proposed Fano locking technique has significant potential to simplify laser locking systems,enhance stability,and reduce overall power consumption and cost.
文摘AIM To compare the outcomes of displaced distal radius fractures treated with volar locking plates and with immediate postoperative mobilisation with the outcomes of these fractures treated with modalities that necessitate 6 wk wrist immobilisation.METHODS A prospective,randomised controlled single-centre trial was conducted with 56 patients who had a displaced radius fracture were randomised to treatment either with a volar locking plate(n=29),or another treatment modality(n=27;cast immobilisation with or without wires or external fixator).Outcomes were measured at 12 wk.Functional outcome scores measured were the Patient-Rated Wrist Evaluation(PRWE)Score;Disabilities of the Arm,Shoulder and Hand and activities of daily living(ADLs).Clinical outcomes were wrist range of motion and grip strength.Radiographic parameters were volar inclination and ulnar variance.RESULTS Patients in the volar locking plate group had significantly better PRWE scores,ADL scores,grip strength and range of extension at three months compared with the control group.All radiological parameters were significantly better in the volar locking plate group at 3 mo.CONCLUSION The present study suggests that volar locking plates produced significantly better functional and clinical outcomes at 3 mo compared with other treatment modalities.Anatomical reduction was significantly more likely to be preserved in the plating group.Level of evidence:Ⅱ.
文摘Complex tibial plateau fractures can seriously affect quality of life and physical and mental health of patients.The anatomical relationship between the proximal tibial bone and soft tissue is complex,resulting in different types of tibial plateau fractures.Violent trauma can lead to displaced fracture,serious soft tissue injury,and potentially,dislocation of the knee joint.Therefore,tibial plateau fractures are extremely unstable.AIM To assess the use of locking compression plate(LCP)+T-type steel plate for postoperative weight bearing and functional recovery of complex tibial plateau fractures.METHODS Ninety-seven patients with complex tibial plateau fractures who underwent surgery at our hospital were selected for retrospective study.Forty-nine patients had been treated with LCP+T-type steel plate limited internal fixation(study group),and 48 patients with bilateral ordinary steel plate support(control group).The operation process index,postoperative rehabilitation related index,Rasmussen score of the knee joint,tibial plateau varus angle(TPA),tibial plateau retroversion angle(PA),and surgical complications of the two groups were compared.RESULTS The operation time and intraoperative bone graft volume in the study group were lower than those in the control group(P<0.05).There were no significant differences in surgical bleeding,anterior external incision length,postoperative drainage,hospital stay duration,and fracture healing time between the groups(P>0.05).There was no significant difference in the TPA and PA angle between the groups immediately and 18 mo after surgery(P>0.05).At 12 mo after surgery,the Rasmussen scale score was higher in the study group than in the control group(P<0.05).There was no significant difference in the Rasmussen scale score at 18 mo after surgery,and the radiology score at 12 and 18 mo after surgery,between the two groups(P>0.05).The postoperative complication rate in the study group(3.77%)was lower than that in the control group(15.09%;P<0.05).CONCLUSION LCP+T-type steel plate internal fixation has advantages in terms of minimizing trauma and enabling early postoperative functional exercise,promoting functional recovery and lower limb weight-bearing,and reducing postoperative complications.
基金Supported by the Key Research Project of StatePower Corporation (SPKJ 0l6-06)the Key Scientific ResearchProject of Hubei Province ( 2004AC101D31)
文摘Contact nonlinear theory was researched. Contact problem was transformed into optimization problem containing Lagrange multiplier, and unsymmetrical stiffness matrix was transformed into symmetrical stiffness matrix. A finite element analysis (FEA) model defining more than 300 contact pairs for long nut-short screw locking mechanism of a large-scale vertical gear-rack typed ship-lift was built. Using augmented Lagrange method and symmetry algorithm of contact element stiffness, the FEA model was analyzed, and the contact stress of contact interfaces and the von Mises stress of key parts were obtained. The results show that the design of the locking mechanism meets the requirement of engineering, and this method is effective for solving large stole nonlinear contact pairs.