期刊文献+
共找到1,123篇文章
< 1 2 57 >
每页显示 20 50 100
MXene-Based Wearable Contact Lenses: Integrating Smart Technology into Vision Care
1
作者 Arezoo Khosravi Atefeh Zarepour +1 位作者 Ali Zarrabi Siavash Iravani 《Nano-Micro Letters》 2026年第1期490-508,共19页
MXene-based smart contact lenses demonstrate a cutting-edge advancement in wearable ophthalmic technology,combining real-time biosensing,therapeutic capabilities,and user comfort in a single platform.These devices tak... MXene-based smart contact lenses demonstrate a cutting-edge advancement in wearable ophthalmic technology,combining real-time biosensing,therapeutic capabilities,and user comfort in a single platform.These devices take the advantage of the exceptional electrical conductivity,mechanical flexibility,and biocompatibility of two-dimensional MXenes to enable noninvasive,tear-based monitoring of key physiological markers such as intraocular pressure and glucose levels.Recent developments focus on the integration of transparent MXene films into the conventional lens materials,allowing multifunctional performance including photothermal therapy,antimicrobial and anti-inflammation protection,and dehydration resistance.These innovations offer promising strategies for ocular disease management and eye protection.In addition to their multifunctionality,improvements in MXene synthesis and device engineering have enhanced the stability,transparency,and wearability of these lenses.Despite these advances,challenges remain in long-term biostability,scalable production,and integration with wireless communication systems.This review summarizes the current progress,key challenges,and future directions of MXene-based smart contact lenses,highlighting their transformative potential in next-generation digital healthcare and ophthalmic care. 展开更多
关键词 MXenes Wearable contact lenses Intraocular lenses Drug delivery Wearable electronics
在线阅读 下载PDF
Red tinted contact lenses on Ishihara test error scores in color deficient subjects:a pilot study
2
作者 Haliza Abdul Mutalib Sharanjeet Sharanjeet-Kaur +3 位作者 Ong Yi Lin Bashirah Ishak MohdNorhafizun Bin Mohd Saman Mohd Izzuddin Hairol 《International Journal of Ophthalmology(English edition)》 2025年第3期462-468,共7页
AIM:To compare the Ishihara test errors scores of colour vision deficiency(CVD)subjects when wearing four different types of red-tinted contact lenses(RCL)that differ in their transmittance as determined using a spect... AIM:To compare the Ishihara test errors scores of colour vision deficiency(CVD)subjects when wearing four different types of red-tinted contact lenses(RCL)that differ in their transmittance as determined using a spectrophotometer.METHODS:Six congenital CVD subjects volunteered to participate in this study.Ishihara plates were used to determine the colour vision errors made,whereas Farnsworth-Munsell 100 Hue test was conducted to determine the total error scores(TES)and type of CVD.Four types of RCL(Types A,B,C and D)were inserted in the non-dominant eye and tested in a randomised manner by a masked operator.Errors scores in Ishihara test were determined at baseline without any contact lens and after wearing the four different RCL.The subjects were then divided into two groups based on the mean TES.RESULTS:Repeated measures ANOVA with Greenhouse-Geisser corrections showed that there was a highly significant effect of RCL type on Ishihara error score[F(2.056,10.282)=30.214,P<0.001].Error scores with RCL Type B were significantly lower than errors made when no lens was worn,and with RCL Type C and Type D(all P<0.001).Error scores with RCL Type B were also lower than those made with RCL Type A,however,they were not significantly different.For subjects with TES values less than 180,RCL type B showed the largest improvement in Ishihara error score(50%)compared to the other three RCLs.RCL type A showed the best performance in TES value of more than 180,with an improvement of 80%in Ishihara score.RCL Type A has the lowest transmittance at the confusion wavelength(450-568 nm),followed by RCL Types B,D and C.CONCLUSION:This study shows that RCL can improve Ishihara error scores.RCL with lower transmission at 450-568 nm and 90%transmittance beyond 637 nm are the most effective.Lenses which could block more light between 550-580 nm are more effective for colour defectives with more severe colour defects. 展开更多
关键词 anomalous trichromats colour vision deficiency contact lenses deutan protan
原文传递
Myopia control efficacy of peripheral defocus modifying spectacle lenses in children and adolescents:a Metaanalysis
3
作者 Hao-Bo Fan Zhi-Lin Li +4 位作者 Xue-Min Zhang Ai-Rui Xie Qiu-Mei Wei Ting-Ting Song Jun-Guo Duan 《International Journal of Ophthalmology(English edition)》 2025年第4期723-734,共12页
AIM:To evaluate the effects of microlens design of peripheral defocus modifying spectacle lenses(PDMSLs)and non-microlens design of PDMSLs on controlling myopia progression in children and adolescents.METHODS:A system... AIM:To evaluate the effects of microlens design of peripheral defocus modifying spectacle lenses(PDMSLs)and non-microlens design of PDMSLs on controlling myopia progression in children and adolescents.METHODS:A systematic search was carried out in the PubMed,Cochrane Library,Embase,CNKI,and Web of Science databases.The search targeted randomized controlled trials(RCTs)and cohort studies(CTs)that explored the effects of PDMSLs on myopia control among children and adolescents.The Cochrane risk-of-bias tool and the Newcastle-Ottawa Scale were employed to evaluate the risk of bias in the included studies.The published biases of the included studies were evaluated using Egger’s test.RESULTS:Nine studies(7 RCTs,2 CTs)were included,involving 4332 participants in the PDMSLs group and 7317 participants in the single vision lenses(SVLs)group.Metaanalysis showed that PDMSLs with microlens design had lower change in spherical equivalent refraction(SER)than SVLs at 6,12,18,and 24mo after wearing glasses,with reductions of 0.19 D(95%CI:0.14 to 0.24,P<0.00001),0.36 D(95%CI:0.25 to 0.46,P<0.00001),0.43 D(95%CI:0.32 to 0.55,P<0.00001),and 0.51 D(95%CI:0.33 to 0.69,P<0.00001),respectively.The changes in axial length(AL)were also lower in PDMSLs compared to SVLs,with reductions of-0.09 mm(95%CI:-0.13 to-0.04,P=0.0002),-0.15 mm(95%CI:-0.21 to-0.08,P<0.00001),-0.27 mm(95%CI:-0.34 to-0.20,P<0.00001),and-0.29 mm(95%CI:-0.38 to-0.20,P<0.00001),respectively.There was no significant difference between the non-microlens group and SVLs in controlling the changes of SER and AL in myopia(both P>0.05).CONCLUSION:The synthesized evidence indicates superior myopia management outcomes with microlens design of PDMSLs compared to both SVLs and nonmicrolens design of PDMSLs in children and adolescents. 展开更多
关键词 peripheral defocus spectacle lenses MYOPIA axial length META-ANALYSIS
原文传递
Impact of LED exposure on contrast sensitivity and protective efficacy of blue-blocking lenses
4
作者 Dolvin Monterio Elizebeth Olive Akansha Manoj Kumar +5 位作者 Mousumi Ghosh Radhika Poojary Judy Jose Judith Shefali Jathanna Manasa Bhandarkar Nagarajan Theruveethi 《International Journal of Ophthalmology(English edition)》 2025年第10期1944-1948,共5页
AIM:To measure the contrast sensitivity(CS)using computer-based Chart2020 software pre-and post-white light exposure with and without blue-blocking lenses(BBLs).METHODS:The study included participants aged 18 to 25y(n... AIM:To measure the contrast sensitivity(CS)using computer-based Chart2020 software pre-and post-white light exposure with and without blue-blocking lenses(BBLs).METHODS:The study included participants aged 18 to 25y(n=30 eyes),where baseline CS was measured before the experiment.Following this,the participants were exposed to two white light-emitting diodes(LEDs;450 lx each),placed at a 45-degree angle from the participant’s eye and 80 cm from the light source.All participants were randomly divided into three groups(BBL1-Placebo lens,BBL2-Crizal Prevencia,BBL3-Duravision)by sequential randomisation,which was double-blinded.Post-light exposure,the CS was measured monocularly with a calibrated computer-based CS Chart-2020 software at different log units.RESULTS:CS measured using Chart-2020 software at 0.8,1.5,6,12,and 18 cpd pre-and post-white LED exposure with and without BBLs showed a significant difference(P<0.05)in contrast threshold and log contrast at 6 cpd and 18 cpd(P<0.05)and showed no significant differences in 0.8,1.5,12 cpd(P>0.05).CONCLUSION:This study shows that exposure to white LEDs can diminish CS,while BBLs may ameliorate these negative effects. 展开更多
关键词 white light-emitting diodes circadian rhythm retinal toxicity blue-blocking lenses contrast sensitivity
原文传递
Ocular biometric parameters associated with the performance of actual near-add power in multifocal intraocular lenses
5
作者 Ying-Feng Hu Yan Wang +2 位作者 Rong Zhang Zheng Wang Xiang-Yu Ye 《International Journal of Ophthalmology(English edition)》 2025年第11期2065-2072,共8页
AIM:To evaluate the influence of ocular biometric parameters on the performance of actual near-add power in the spectacle plane of multifocal intraocular lenses(MIOLs).METHODS:This retrospective study defined predicti... AIM:To evaluate the influence of ocular biometric parameters on the performance of actual near-add power in the spectacle plane of multifocal intraocular lenses(MIOLs).METHODS:This retrospective study defined prediction error(PE)as the difference between actual postoperative near-add power and manufacturer-predicted values.Linear regression assessed PE correlations with axial length(AL),mean keratometry(K),pupil size,anterior chamber depth(ACD),lens thickness(LT),ACD+0.5×LT,and back-calculated IOL power.Differences in PE across MIOLs types,AL,K,pupil size,ACD,LT,ACD+0.5×LT,and back-calculated IOL power groups were compared.RESULTS:Totally 250 eyes of 250 patients(116 males and 134 females,mean age 56.22±12.31y)who underwent phacoemulsification with MIOL implantation were reviewed.PE showed no significant correlation with most parameters but had a weak positive correlation with LT.The mean predicted error(MPE)in the AL≤22,26–27,and 27–28 mm groups were 0.83(0.51,1.01)D,0.78(0.51,1.07)D,and 0.72(0.57,0.94)D respectively(P<0.001).The MPE in the K between the 45–46 D groups was 0.78(0.37,1.07)D(P=0.0004).The MPE in the LT between the 4.5–5.0 mm groups and≥5 mm was 0.72(0.50,1.01)D and 0.72(0.51,1.01)D respectively(P<0.001).The MPE in the back-calculated IOL power≥25 D was 0.86(0.60,1.01)D(P<0.001).CONCLUSION:Although there is no significant linear relationship between near-add power and most ocular biometry parameters,and specific segments of AL,K,LT,and IOL power have a significant impact on the near-add power of MIOLs.These factors should be taken into account in preoperative evaluations. 展开更多
关键词 near-add power multifocal intraocular lenses spectacle plane
原文传递
Bibliometric and visual analysis of scleral contact lenses:global characteristics and research trends from 1976 to 2023
6
作者 Jing Gao Yao Xu 《International Journal of Ophthalmology(English edition)》 2025年第4期735-743,共9页
AIM:To gain insight into the future research directions in scleral contact lenses(SCLs)through a comprehensive bibliometrics study.METHODS:The publications related to SCLs were screened from the Web of Science Core Co... AIM:To gain insight into the future research directions in scleral contact lenses(SCLs)through a comprehensive bibliometrics study.METHODS:The publications related to SCLs were screened from the Web of Science Core Collection(WOSCC)database.All bibliographic information was extracted and used to conduct a performance analysis.CiteSpace and VOSviewer were employed to visualize annual publication counts,journals,authors,countries,institutions,collaboration networks,keywords,and references.RESULTS:A total of 498 articles were included in our analysis and the number of publications about SCLs showed a significant yearly increase.These publications predominantly emanated from 523 institutions across 38 countries,with the United States and Australia leading in frequency.Totally 1361 authors were identified,among whom Vincent J.Stephen exhibited the highest number of publications,while Jacobs S.Deborah received the most citations.Notably,the journal Contact Lens&Anterior Eye emerged as the primary publisher of studies,and it also boasted the highest citation rate.“Fluid-ventilated,gas-permeable scleral contact lens is an effective option for managing severe ocular surface disease and many corneal disorders that would otherwise require penetrating keratoplasty”was the most cited paper published in eye&contact lens in 2005.The most prevalent keywords encompassed“keratoconus”,“scleral contact lenses”,“management”,“contact lenses”,“scleral contact lens”,“ocular surface disease”,“dry eye”,and“contact lens”.CONCLUSION:Although SCLs have demonstrated significant potential in ophthalmological care,the results offer valuable insights pertinent to future research directions and clinical practice.Greater emphasis should be placed on developing enhancements in design,materials,and fitting technique,as well as on reducing the complications associated with SCLs. 展开更多
关键词 scleral contact lenses bibliometric analysis visual analysis
原文传递
Comparison of visual acuity and optical quality between higher-order aspheric monofocal and standard introcular lenses
7
作者 Andrea Janekova Martina Polachova +1 位作者 David P.Piñero Pavel Studeny 《International Journal of Ophthalmology(English edition)》 2025年第4期598-605,共8页
AIM:To compare the 12-month outcomes of visual performance and patient satisfaction of a higherorder aspheric monofocal intraocular lens(IOL)and a conventional monofocal IOL.METHODS:Prospective,randomized,comparative,... AIM:To compare the 12-month outcomes of visual performance and patient satisfaction of a higherorder aspheric monofocal intraocular lens(IOL)and a conventional monofocal IOL.METHODS:Prospective,randomized,comparative,double-blinded study including 22 patients who underwent bilateral cataract surgery with implantation of the Tecnis Eyhance ICB00 IOL in one eye(ICB00 group)and the Tecnis ZCB00 IOL in the fellow eye(ZCB00 group).Uncorrected distance(UDVA),corrected distance(CDVA),uncorrected intermediate(UIVA),distance-corrected intermediate(DCIVA),uncorrected near(UNVA),and distance-corrected near visual acuities(DCNVA)were evaluated during a 12-month follow-up.Contrast sensitivity,defocus curves,and reading text size were also evaluated.Patient satisfaction was assessed with a questionnaire at the 6-month postoperative visit.RESULTS:Mean postoperative logMAR UDVA was 0.01±0.12 and-0.02±0.10 in ICB00 and ZCB00 groups,respectively(P=0.37).Mean logMAR UIVA was 0.32±0.19 and 0.45±0.16 in ICB00 and ZCB00 groups,respectively(P=0.010).Differences between groups in UNVA did not reach statistical significance(P=0.16).The intermediate reading acuity at 66 cm(P=0.02)and 80 cm(P=0.04)was significantly better in the ICB00 group.Postoperative contrast sensitivity results did not differ significantly between groups(P>0.05).Patients reported high overall satisfaction,with 62%of patients using spectacles for reading in everyday life.CONCLUSION:The eyes of patients implanted with the enhanced monofocal IOL evaluated have significantly better visual acuity for intermediate distances with the same contrast sensitivity as a conventional monofocal IOL. 展开更多
关键词 enhanced monofocal intraocular lens Tecnis Eyhance contrast sensitivity intermediate visual acuity
原文传递
Considerations in the management of single-piece intraocular lenses outside the capsular bag
8
作者 Anna K Junk 《World Journal of Ophthalmology》 2014年第3期87-91,共5页
AIM: To investigate the outcomes of off label singlepiece acrylic intraocular lenses(SPA-IOL) ciliary sulcus placement compared to three-piece IOL(3P-IOL). METHODS: The charts of eight consecutive eyes of patients who... AIM: To investigate the outcomes of off label singlepiece acrylic intraocular lenses(SPA-IOL) ciliary sulcus placement compared to three-piece IOL(3P-IOL). METHODS: The charts of eight consecutive eyes of patients who received sulcus-placed SPA-IOLs between 2006 and 2009 were reviewed. None of the patients underwent IOL exchange. Charts of six age-matched patients who received sulcus placed 3P-IOLs were reviewed as a control group. RESULTS: Mean follow up was 16 mo for SPA-IOL and 23 mo for 3P-IOL. Five of 8 patients in the SPA-IOL group required chronic use of IOP lowering medications at final follow up. Of these, one patient needed glaucoma implant surgery for uncontrolled IOP. One patient in the 3P-IOL group used chronic aqueous suppression pre- and postoperatively. Four of eight eyes with SPAIOL were treated with chronic topical steroids and or non-steroidal anti-inflammatory drugs for cystoid macu-la edema, chronic uveitis, pigment dispersion syndrome or a combination of the above, compared to none in the control group. Mean best-corrected visual acuity was 20/35 in the SPA-IOL group and 20/47 in the 3PIOL group.CONCLUSION: Sulcus placed SPA-IOLs are associated with increased ocular morbidity. In select cases good visual acuity may be achieved. Due to postoperative rotation of sulcus placed toric SPA-IOLs stable astigmatism correction cannot be achieved. Alternative intraocular lenses should be considered when in-the-bag placement of SPA-IOL is not possible. 展开更多
关键词 Cataract surgery Sulcus intraocular lens implant Single piece intraocular lenses Three piece intraocular lenses Posterior capsule tear Cataract surgery complication Pigment dispersion Cystoid macula edema Anterior vitrectomy
暂未订购
Zoned Zircon from Eclogite Lenses in Marbles from the Dabie-Sulu UHP Terrane,China: A Clear Record of Ultra-deep Subduction and Fast Exhumation 被引量:19
9
作者 LIU Fulai A. GERDES +2 位作者 P. T. ROBINSON XUE Huaimin YE Jianguo 《Acta Geologica Sinica(English Edition)》 SCIE CAS CSCD 2007年第2期204-225,共22页
Eclogite lenses in marbles from the Dabie-Sulu ultrahigh-pressure (UHP) terrane are deeply subducted meta-sedimentary rocks. Zircons in these rocks have been used to constrain the ages of prograde and UHP metamorphi... Eclogite lenses in marbles from the Dabie-Sulu ultrahigh-pressure (UHP) terrane are deeply subducted meta-sedimentary rocks. Zircons in these rocks have been used to constrain the ages of prograde and UHP metamorphism during subduction, and later retrograde metamorphism during exhumation. Inherited (detrital) and metamorphic zircons were distinguished on the basis of transmitted light microscopy, cathodoluminescence (CL) imaging, trace element contents and mineral inclusions. The distribution of mineral inclusions combined with CL imaging of the metamorphic zircon make it possible to relate zircon zones (domains) to different metamorphic stages. Domain 1 consists of rounded, oblong and spindly cores with dark-luminescent images, and contains quartz eclogite facies mineral inclusion assemblages, indicating formation under high-pressure (HP) metamorphic conditions of T = 571-668℃ and P =1.7-2.02 GPa. Domain 2 always surrounds domain 1 or occurs as rounded and spindly cores with white-luminescent images. It contains coesite eclogite facies mineral inclusion assemblages, indicating formation under UHP metamorphic conditions of T = 782-849℃ and P 〉 5.5 GPa. Domain 3, with gray-luminescent images, always surrounds domain 2 and occurs as the outermost zircon rim. It is characterized by low-pressure mineral inclusion assemblages, which are related to regional amphibolite facies retrograde metamorphism of T = 600- 710℃ and P = 0.7-1.2 GPa. The three metamorphic zircon domains have distinct ages; sample H1 from the Dabie terrane yielded SHRIMP ages of 245 ± 4 Ma for domain 1, 235 ± 3 Ma for domain 2 and 215± 6 Ma for domain 3, whereas sample H2 from the Sulu terrane yielded similar ages of 244 ± 4 Ma, 233 ± 4 Ma and 214 ± 5 Ma for Domains 1, 2 and 3, respectively. The mean ages of these zones suggest that subduction to UHP depths took place over 10-11 Ma and exhumation of the rocks occurred over a period of 19-20 Ma. Thus, subduction from - 55 km to 〉 160 km deep mantle depth took place at rates of approximately 9.5-10.5 km/Ma and exhumation from depths 〉160 km to the base of the crust at -30 km occurred at approximately 6.5 km/Ma. We propose a model for these rocks involving deep subduction of continental margin lithosphere followed by ultrafast exhumation driven by buoyancy forces after break-off of the UHP slab deep within the mantle. 展开更多
关键词 zoned zircon SHRIMP U-Pb dating ultra-deep subduction fast exhumation eclogite lenses in marble Dabie-Sulu UHP belt
在线阅读 下载PDF
Electrostatic-lenses position-sensitive TOF MCP detector for beam diagnostics and new scheme for mass measurements at HIAF 被引量:12
10
作者 Jun-Hao Liu Zhuang Ge +7 位作者 Qian Wang Geng Wang Li-Na Sheng Wen-Wen Ge Xing Xu Peng Shuai Qi Zeng Bo Wu 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第10期63-73,共11页
A foil–microchannel plate(MCP)detector,which uses electrostatic lenses and possesses both good position and timing resolutions,has been designed and simulated for beam diagnostics and mass measurements at the next-ge... A foil–microchannel plate(MCP)detector,which uses electrostatic lenses and possesses both good position and timing resolutions,has been designed and simulated for beam diagnostics and mass measurements at the next-generation heavy-ion-beam facility HIAF in China.Characterized by low energy loss and good performances of timing and position measurements,it would be located at focal planes in fragment separator HFRS for position monitoring,beam turning,Bq measurement,and trajectory reconstruction.Moreover,it will benefit the building-up of a magnetic-rigidity–energy-loss–time-offlight(BqDETOF)method at HFRS for high-precision in-flight particle identification of radioactive isotope beams on an event-by-event basis.Most importantly,the detector can be utilized for in-ring TOF and position measurements,beam-line TOF measurements at two achromatic foci,and position measurements at a dispersive focus of HFRS,thus making it possible to use two complementary mass measurement methods[isochronous mass spectrometry at the storage ring SRing and magnetic-rigidity–time-of-flight(BqTOF)at the beam-line HFRS]in one single experimental run. 展开更多
关键词 MICROCHANNEL plate ELECTROSTATIC lenses DETECTOR POSITION-SENSITIVE TIME-OF-FLIGHT Mass measurements HIAF
暂未订购
Visual performance after implantation of two types of phakic foldable intraocular lenses for correction of high myopia 被引量:4
11
作者 Islam M.Rizk Abd-Almonem A.Al-hessy +1 位作者 Sherief E.El-Khouly Ashraf M.Sewelam 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2019年第2期284-290,共7页
AIM: To compare Visian lens(model V4 c) and Artiflex lens regarding quality(contrast sensitivity) and quantity(efficacy, predictability, safety and stability) of vision in correcting high myopia with recording and ana... AIM: To compare Visian lens(model V4 c) and Artiflex lens regarding quality(contrast sensitivity) and quantity(efficacy, predictability, safety and stability) of vision in correcting high myopia with recording and analysis of complications. METHODS: The comparative prospective study included 39 eyes of 23 patients with high myopia, 19 eyes had Visian lens implantation(model V4 c) and 20 eyes had Artiflex lens implantation. The inclusion criteria were high myopia(higher than 6.0 D) and stable refraction(<0.5 D change over one year). Outcomes included assessment of safety and efficacy indices, predictability, stability, contrast sensitivity and analysis of complications at postoperative 1 d, 1 wk and 1, 3, 6 and 12 mo. Selection of the type of phakic intraocular lens for patients was based on surgeons' preferences, which was no specific selection criteria. RESULTS: After 12 mo of follow up, difference in uncorrected and corrected distant visual acuity(CDVA) between both groups was statistically insignificant(UDVA for VisianV4 c and Artiflex lens were 0.33±0.2 logMAR and 0.37±0.2 logMAR respectively, P=0.59, CDVA for VisianV4 c and Artiflex lens were 0.155±0.1 logMAR and 0.147± 0.1 logMAR respectively, P=0.87). The efficacy index was 1.25 for VisianV4 c lens and 0.8 for Artiflex lens, 78.9% of eyes were within one diopter spherical equivalent in Visian V4 c lens group compared to 70% in the Artiflex lens group. No eye lost lines of CVDA proving a good safety index for both lenses(safety index was 1.67 for VisianV4 c lens and 1.34 for Artiflex lens). Difference in contrast sensitivity between both groups was statistically insignificant(P=0.15, 0.88, 0.27, 0.32 and 0.82 at five spatial frequencies). CONCLUSION: Both Visian ICL V4 c and Artiflex lensesare safe and effective with stable and predictable refraction and they have comparable contrast sensitivity outcomes with no vision threatening complications. 展开更多
关键词 PHAKIC INTRAOCULAR lenses IMPLANTABLE collamer Visian V4c LENS foldable Artiflex LENS
原文传递
Role of short-wavelength filtering lenses in delaying myopia progression and amelioration of asthenopia in juveniles 被引量:7
12
作者 Hai-Lan Zhao Jin Jiang +1 位作者 Jie Yu Hai-Ming Xu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第8期1261-1267,共7页
AIM: To evaluate the positive effects of blue-violet light filtering lenses in delaying myopia and relieving asthenopia in juveniles. METHODS: Sixty ametropia juveniles (aged range, 11-15y) were randomized into t... AIM: To evaluate the positive effects of blue-violet light filtering lenses in delaying myopia and relieving asthenopia in juveniles. METHODS: Sixty ametropia juveniles (aged range, 11-15y) were randomized into two groups: the test group (30 children, 60 eyes), wearing blue-violet light filtering lenses; and the control group (30 children, 60 eyes), wearing ordinary aspherical lenses. Baseline refractive power of the affected eyes and axial length of the two groups was recorded. After 1-year, the patients underwent contrast sensitivity (glare and non-glare under bright and dark conditions), accommodation-related testing, asthenopia questionnaire assessment, and adverse reaction questionnaire assessment. RESULTS: After ly of wearing the filtering lenses, changes in refractive power and axial length were not significantly different between the two groups (P〉0.05). Under bright conditions, the contrast sensitivities at low and medium- frequency grating (vision angles of 6.3, 4.0, and 2.5) with glare in the test group were significantly higher than in the control group (P〈0.05), while the contrast sensitivity at low-frequency grating (vision angles of 6.3 and 4.0) in the absence of glare in the test group was higher than in the control group (P〈0.05). Under glare and non-glare dark conditions, the contrast sensitivities of various frequencies in the test group did not show significant differences compared with those in the control group (P〉0.05). In the test group, the amplitude of accommodation, accommodative lag, and accommodative sensitivity of patients wearing glasses for 6 and 12mo were significantly elevated (P〈0.05), while the asthenopia gratings were significantly decreased (P〈0.05). Nevertheless, in the control group,the amplitude of accommodation, accommodative lag, and accommodative sensitivity after 12mo were not significantly altered compared with baseline (P〉0.05), and the asthenopia grating was not significantly decreased (P〉0.05). In addition, after wearing glasses for 6 to 12mo, the asthenopia grating of patients in the test group decreased significantly compared with the control group (P〈0.05). At 12mo, the constituent ratio of adverse reactions did not show significant difference between the two groups (P〉0.05). CONCLUSION: A l-year follow-up reveal that compare with ordinary glasses, short-wavelength filtering lenses (blue/ violet-light filters) increase the low- and medium-frequency contrast sensitivity under bright conditions and improved accommodation. They effectively relieved asthenopia without severe adverse reactions, suggesting potential for clinical application. However, no significant advantages in terms of refractive power or axial length progression were found compared with ordinary aspheric lenses. 展开更多
关键词 short-wavelength filtering lenses ASTHENOPIA juvenile myopia
原文传递
Higher order aberration comparison between two aspherical intraocular lenses: MC6125AS and Akreos advanced optics 被引量:5
13
作者 Mohammad Taher Rajabi Sara Korouji +4 位作者 Mahgol Farjadnia Mohammad Naderan Mohammad Bagher Rajabi Bahram Khosravi Seyed Mehdi Tabatabaie 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2015年第3期565-568,共4页
AIM: To compare higher order aberrations in two aspherical intraocular lenses(IOLs): Akreos advanced optics(AO) and Dr. Schmidt Microcrystalline 6125 aspheric anterior surface(MC6125AS) with each other. METHODS: Forty... AIM: To compare higher order aberrations in two aspherical intraocular lenses(IOLs): Akreos advanced optics(AO) and Dr. Schmidt Microcrystalline 6125 aspheric anterior surface(MC6125AS) with each other. METHODS: Forty eyes of 39 patients underwent phacoemulsification and Akreos AO and MC6125 AS were implanted in their eyes in a random manner. Three months post-operatively, higher order aberrations including spherical aberration, coma aberration, and total aberrations were measured and compared.RESULTS: The total aberration was 0.24±0.17 in eyes with Dr. Schmidt and 0.20 ±0.01 in eyes with Akreos AO(P =0.361). The mean of coma aberration was 0.17 ±0.21 and 0.09 ±0.86 in Dr. Schmidt and Akreos lenses,respectively(P =0.825). Total spherical aberration was almost the same in both groups(mean: 0.05, P =0.933).Best corrected visual acuity in Akreos AO(0.10±0.68) and Dr. Schmidt(0.09±0.67) did not differ significantly(P =0.700). CONCLUSION: There is no statistically significant difference in the higher order aberrations between these two aspherical lenses. 展开更多
关键词 aspherical lenses higher order aberrations CATARACT intraocular lens
原文传递
Distance vision after bilateral implantation of AcrySof toric intraocular lenses:a randomized,controlled,prospective trial 被引量:4
14
作者 Jin-Song Zhang Jiang-Yue Zhao +1 位作者 Qi Sun and Li-Wei Ma 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2011年第2期175-178,共4页
·AIM:To evaluate the distance vision of Chinese patients with cataracts and corneal astigmatism after implantation of bilateral AcrySof toric intraocular lens (IOL) versus bilateral AcrySof spherical IOL.·ME... ·AIM:To evaluate the distance vision of Chinese patients with cataracts and corneal astigmatism after implantation of bilateral AcrySof toric intraocular lens (IOL) versus bilateral AcrySof spherical IOL.·METHODS:This study randomized 60 patients into equal groups to receive toric IOL or spherical IOL.IOL powers targeting emmetropia were selected for 93% of toric IOL patients and for 90% of spherical IOL patients.Assessments included monocular and binocular distance vision,with and without best correction.Patients also completed surveys about their distance vision.·RESULTS:Preoperatively,the two study groups were similar in age,in distance visual acuity,and in the magnitude of corneal astigmatism.At 6 months postoperative,binocular uncorrected distance vision was 0.06?à0.14 logMAR in the AcrySof toric IOL group,significantly better than the 0.14?à0.11 logMAR in the spherical IOL group (P<0.05).For eyes with emmetropia as a target,the equivalent of 20/20 uncorrected vision was more likely (P<0.001) in the toric IOL group (36% of eyes) than in the spherical IOL group (4% of eyes).No patients in the emmetropia/toric IOL group used distance glasses,as compared to 52% of patients in the emmetropia/spherical IOL group.All patients were satisfied or highly satisfied.Quality of distance vision was rated higher by toric IOL patients than by spherical IOL patients (P<0.05).·CONCLUSION:Bilateral AcrySof toric IOL is superior to bilateral spherical IOL in providing uncorrected distance vision to cataract patients with corneal astigmatism.· 展开更多
关键词 ASTIGMATISM cataract extraction lenses INTRAOCULAR PSEUDOPHAKIA
原文传递
Study on the surface properties of surface modified silicone intraocular lenses 被引量:3
15
作者 Gui-Qin Wang Han-Qing Gu and Xiu-Jun Peng 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2012年第1期84-87,共4页
AIM: To prepare a new-type soft intraocular lens (IOL) that silicone intraocular lenses (IOLs) were modified by surface modification technique to assess IOLs biocompatibility. METHODS: With the technique of ion beam c... AIM: To prepare a new-type soft intraocular lens (IOL) that silicone intraocular lenses (IOLs) were modified by surface modification technique to assess IOLs biocompatibility. METHODS: With the technique of ion beam combined with low temperature and low pressure plasma, the surface characteristics of the IOLs including physical and optical properties were determined by the instruments of IOLs resolution, UV/VIS scanning spectrophotometer, contact angle measurement system, electron spectroscopy for chemical analysis (ESCA) and scanning electron microscope (SEM). RESULTS: The color of titanium (Ti) modified IOLs was light yellow and that of titanium nitride (TiN) modified IOLs was light brown. The absorptive degree of ultraviolet rays and the hydrophilicity of the surfaces of modified IOLs were increased, and appeared suitable chemical compositions. The resolution of unmodified and modified IOLs reached normal standard. The surfaces of unmodified and Ti-modified IOLs appeared uniform. The surfaces of TIN-modified IOLs presented fine porcelain structure. CONCLUSION: The optical properties of all IOLs and the surface morphology of the modified IOLs were not affected by modification processes. The surface properties of the modified IOLs were improved. 展开更多
关键词 SILICONE intraocular lenses surface modification technique surface property BIOCOMPATIBILITY
原文传递
Effectiveness of peripheral defocus spectacle lenses in myopia control: a Meta-analysis and systematic review 被引量:3
16
作者 Ji-Xian Ma Si-Wen Tian Qiu-Ping Liu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2022年第10期1699-1706,共8页
AIM: To evaluate the effectiveness of peripheral defocus spectacle lenses(PDLs) in myopia control. METHODS: Literature retrieval on Pub Med, Cochrane Library, Embase, and Web of Science databases, and the search time ... AIM: To evaluate the effectiveness of peripheral defocus spectacle lenses(PDLs) in myopia control. METHODS: Literature retrieval on Pub Med, Cochrane Library, Embase, and Web of Science databases, and the search time limit was from the establishment of each database to December 29, 2021 were conducted. Change of spherical equivalent refraction(SER) and axial change(AL) were extracted from the literatures that met the inclusion criteria, and Rev Man5.3 software was used for Meta-analysis. RESULTS: A total of 4 randomized controlled trials(RCTs) were included in this Meta-analysis, involving 770 myopic children. The results showed that PDLs could delay the progression of myopia in children with myopia compared with single vision spectacle lenses(SVLs;WMD=0.21 D, 95%CI: 0.01, 0.41, P=0.04). However, there was no significant difference in controlling the growth of axial length(AL) in myopic children(WMD=-0.10 mm, 95%CI:-0.21, 0.01, P=0.07). The results of the effectiveness of myopia control between the two spectacle lenses showed that PDLs were more effective in controlling the progression of myopia(OR=5.73, 95%CI: 2.58, 12.70, P<0.001) and delaying the growth of AL(OR=44.25, 95%CI: 8.84, 221.58, P<0.001) than SVLs, and the differences were statistically significant. CONCLUSION: PDLs can control the progression of myopia compared with SVLs, but cannot delay the growth of AL, and the effectiveness of PDLs in myopia control better than SVLs. 展开更多
关键词 META-ANALYSIS peripheral defocus spectacle lenses hyperopia defocus myopia defocus myopia control
原文传递
F-heparin modified intraocular lenses in Rhesus monkeys 被引量:2
17
作者 Gui-Qin Wang Han-Qing Gu +2 位作者 Jia-Qin Yuan Hui-Min Sun and Yan-Shan Xu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2010年第2期141-144,共4页
AIMIn order to improve the biocompatibility of intraocular lenses (IOL), the polymethylmethacrylate (PMMA) IOL was modified with F-heparin.
关键词 intraocular lenses F-heparin surface modification BIOCOMPATIBILITY Rhesus monkeys
原文传递
Numerical simulation of cyclic behavior of double sand lenses and corresponding liquefaction-induced soil settlement 被引量:2
18
作者 Y.PASHANG PISHEH S.M.MIR MOHAMMAD HOSSEINI 《Journal of Central South University》 SCIE EI CAS 2010年第3期593-602,共10页
A two-dimensional numerical model was used to explain the liquefaction mechanism of double sand lenses and the corresponding soil deformation due to the cyclic loading. Moreover, in order to investigate the influences... A two-dimensional numerical model was used to explain the liquefaction mechanism of double sand lenses and the corresponding soil deformation due to the cyclic loading. Moreover, in order to investigate the influences of the soil characteristics and input loading data a parametric study was carried out on the essential parameters affecting the soil settlement, and so the variation of these parameters with the corresponding displacements was mainly examined. At last, the results obtained from the numerical analyses of double sand lenses and a continuous sand layer with similar characteristics were compared with those of an estimating method proposed by ISHIHARA and YOSHIMINE. The comparisons show that the settlements due to liquefaction of the continuous sand layer in both numerical and the estimating method are in a good agreement with and are obviously greater than those of double sand lenses. 展开更多
关键词 LIQUEFACTION ground failure cyclic loading double sand lenses DEFORMATION
在线阅读 下载PDF
Objective assessment of the effect of pupil size upon the power distribution of multifocal contact lenses 被引量:2
19
作者 Eleni Papadatou Antonio J.Del Aguila-Carrasco +2 位作者 Jose J.Esteve-Taboada David Madrid-Costa Alejandro Cervino-Exposito 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第1期103-108,共6页
AIM: To analytically assess the effect of pupil size upon the refractive power distributions of different designs of multifocal contact lenses.METHODS: Two multifocal contact lenses of center-near design and one mul... AIM: To analytically assess the effect of pupil size upon the refractive power distributions of different designs of multifocal contact lenses.METHODS: Two multifocal contact lenses of center-near design and one multifocal contact lens of center-distance design were used in this study. Their power profiles were measured using the NIMO TR1504 device (LAMBDA-X, Belgium). Based on their power profiles, the power distribution was assessed as a function of pupil size. For the high addition lenses, the resulting refractive power as a function of viewing distance (far, intermediate, and near) and pupil size was also analyzed.RESULTS: The power distribution of the lenses was affected by pupil size differently. One of the lenses showed a significant spread in refractive power distribution, from about ?3 D to 0 D. Generally, the power distribution of the lenses expanded as the pupil diameter became greater. The surface of the lens dedicated for each distance varied substantially with the design of the lens.CONCLUSION: In an experimental basis, our results show how the lenses power distribution is affected by the pupil size and underlined the necessity of careful evaluation of the patient’s visual needs and the optical properties of a multifocal contact lens for achieving the optimal visual outcome. 展开更多
关键词 multifocal contact lenses pupil size power profiles refractive power distribution
原文传递
Effectivity and safety of trifocal intraocular lenses and capsular tension rings implantation for cataract patients with axial high myopia 被引量:2
20
作者 Shan Hua Qiu-Xia Xie +1 位作者 Hu Wang Jing-Xiang Zhong 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第3期499-508,共10页
●AIM:To assess effectivity and safety of trifocal intraocular lenses(IOLs)and capsular tension rings in treating cataract patients with axial high myopia.●METHODS:A prospective nonrandomized controlled clinical tria... ●AIM:To assess effectivity and safety of trifocal intraocular lenses(IOLs)and capsular tension rings in treating cataract patients with axial high myopia.●METHODS:A prospective nonrandomized controlled clinical trial was conducted.Totally 98 eyes(74 patients)who underwent femtosecond laser-assisted cataract surgery(FLACS)with trifocal IOLs were enrolled in the study and followed up for 2y after surgery:46 eyes(33 patients)with capsular tension ring implantation in the long axial lengths(AL)group(26<AL<29 mm)and 52 eyes(41 patients)in the normal AL group(22<AL<24.5 mm).Postoperative outcomes about effectivity and safety,including the subjective and objective visual quality,and postoperative complications were assessed.●RESULTS:Uncorrected distance visual acuity at 5 m and uncorrected intermediate visual acuity at 60 and 80 cm in the long AL group were significantly worse than those in the normal AL group at 3mo postoperatively(P<0.05).The differences in reading speed,spectacle independence and potential visual complaints between the two groups were not statistically significant(P>0.05).The dysfunctional lens index and total modulation transfer function(MTF)average height were similar between the two groups.The postoperative internal coma aberrations in the axial high myopia eyes were significantly higher than that in the normal AL group(P<0.05).The total satisfaction score in the long AL group(91.32±2.76)was slightly higher than that in the normal AL group(90.36±3.47),but there was no difference(P=0.136).A statistically negative correlation was found between corrected distance visual acuity(CDVA)and dysfunctional lens index(r=-0.382,P=0.009),and between CDVA and the total MTF average height(r=-0.374,P=0.01).But there was no significant correlation between CDVA and total satisfaction score(r=0.059,P=0.696).Postoperative complications mainly presented as posterior capsular opacity(PCO),retinal detachment and cystoid macular edema.There was no difference in the incidence of fundus disease(6.5%vs 3.8%,P=0.663)or PCO(17.4%vs 7.7%,P=0.217)between the two groups at two years.●CONCLUSION:The utilization of trifocal IOL and capsular tension ring implantation is beneficial for cataract patients with axial high myopia undergoing FLACS.This approach not only ensures excellent subjective feelings and objective visual quality,but also does not increase the incidence of postoperative complications. 展开更多
关键词 trifocal intraocular lenses capsular tension ring axial high myopia CATARACT visual quality
原文传递
上一页 1 2 57 下一页 到第
使用帮助 返回顶部