A large-span steel–concrete composite beam with precast hollow core slabs(CBHCSs)is a relatively new floor structure that can be applied to various long-span structures.However,human-induced vibrations may present se...A large-span steel–concrete composite beam with precast hollow core slabs(CBHCSs)is a relatively new floor structure that can be applied to various long-span structures.However,human-induced vibrations may present serviceability issues in such structures.To alleviate vibrations,both the walking forces excited by humans and the associated floor responses must be elucidated.In this study,150 load–time histories of walking,excited by 25 test participants,are obtained using a force measuring plate.The dynamic loading factors and phase angles in the Fourier series functions for one-step walking are determined.Subsequently,walking tests are performed on seven CBHCS specimens to capture the essential dynamic properties of mode shapes,natural frequencies,damping ratios,and acceleration time histories.The CBHCS floor system generally exhibits a high frequency(>10 Hz)and low damping(damping ratio<2%).Sensitivity studies using the finite element method are conducted to investigate the vibration performance of the CBHCS floor system,where the floor thickness,steel beam type,contact time,and human weight are considered.Finally,analytical expressions derived for the fundamental frequency and peak acceleration agree well with the experimental results and are hence proposed for practical use.展开更多
Gaussian beam migration (GBM) is an effec- tive and robust depth seismic imaging method, which overcomes the disadvantage of Kirchhoff migration in imaging multiple arrivals and has no steep-dip limitation of one-wa...Gaussian beam migration (GBM) is an effec- tive and robust depth seismic imaging method, which overcomes the disadvantage of Kirchhoff migration in imaging multiple arrivals and has no steep-dip limitation of one-way wave equation migration. However, its imaging quality depends on the initial beam parameters, which can make the beam width increase and wave-front spread with the propagation of the central ray, resulting in poor migration accuracy at depth, especially for exploration areas with complex geological structures. To address this problem, we present an adaptive focused beam method for shot-domain prestack depth migration. Using the infor- mation of the input smooth velocity field, we first derive an adaptive focused parameter, which makes a seismic beam focused along the whole central ray to enhance the wave- field construction accuracy in both the shallow and deep regions. Then we introduce this parameter into the GBM, which not only improves imaging quality of deep reflectors but also makes the shallow small-scale geological struc- tures well-defined. As well, using the amplitude-preserved extrapolation operator and deconvolution imaging condi- tion, the concept of amplitude-preserved imaging has been included in our method. Typical numerical examples and the field data processing results demonstrate the validity and adaptability of our method.展开更多
The applications of carbon ion beam in tumor therapy have attracted more attention in recent years.Monte Carlo simulation is an important approach to obtain accurate radiotherapy parameters. In this work, a400 Me V/u ...The applications of carbon ion beam in tumor therapy have attracted more attention in recent years.Monte Carlo simulation is an important approach to obtain accurate radiotherapy parameters. In this work, a400 Me V/u carbon ion beam incident on water phantom was simulated with Gate/Geant4 tools. In methods, the authors set up a carbon ion beam source according to the experiment parameters of Haettner, defined the geometries and materials, set up the physics processes, and designed the means of information collection. In results,the authors obtained the longitudinal dose distribution, the lateral dose distribution, and the relative uncertainty of dose. The dose contributions of all kinds of fragments were calculated detailedly and compared with the Francis results. This work is helpful for people's understanding of the dose distributions produced by carbon ion beam and fragments in water. The simulation method is also significative for radiotherapy treatment planning of carbon ion beam, and it is easy to extend. For obtaining a special result, we may change the particle energy, particle type,target material, target geometry, physics process, detector,etc.展开更多
基金The authors acknowledge the financial support provided by the National Natural Science Foundation of China(51890902 and 51708058).
文摘A large-span steel–concrete composite beam with precast hollow core slabs(CBHCSs)is a relatively new floor structure that can be applied to various long-span structures.However,human-induced vibrations may present serviceability issues in such structures.To alleviate vibrations,both the walking forces excited by humans and the associated floor responses must be elucidated.In this study,150 load–time histories of walking,excited by 25 test participants,are obtained using a force measuring plate.The dynamic loading factors and phase angles in the Fourier series functions for one-step walking are determined.Subsequently,walking tests are performed on seven CBHCS specimens to capture the essential dynamic properties of mode shapes,natural frequencies,damping ratios,and acceleration time histories.The CBHCS floor system generally exhibits a high frequency(>10 Hz)and low damping(damping ratio<2%).Sensitivity studies using the finite element method are conducted to investigate the vibration performance of the CBHCS floor system,where the floor thickness,steel beam type,contact time,and human weight are considered.Finally,analytical expressions derived for the fundamental frequency and peak acceleration agree well with the experimental results and are hence proposed for practical use.
文摘Gaussian beam migration (GBM) is an effec- tive and robust depth seismic imaging method, which overcomes the disadvantage of Kirchhoff migration in imaging multiple arrivals and has no steep-dip limitation of one-way wave equation migration. However, its imaging quality depends on the initial beam parameters, which can make the beam width increase and wave-front spread with the propagation of the central ray, resulting in poor migration accuracy at depth, especially for exploration areas with complex geological structures. To address this problem, we present an adaptive focused beam method for shot-domain prestack depth migration. Using the infor- mation of the input smooth velocity field, we first derive an adaptive focused parameter, which makes a seismic beam focused along the whole central ray to enhance the wave- field construction accuracy in both the shallow and deep regions. Then we introduce this parameter into the GBM, which not only improves imaging quality of deep reflectors but also makes the shallow small-scale geological struc- tures well-defined. As well, using the amplitude-preserved extrapolation operator and deconvolution imaging condi- tion, the concept of amplitude-preserved imaging has been included in our method. Typical numerical examples and the field data processing results demonstrate the validity and adaptability of our method.
基金supported by the National Natural Science Foundation of China(No.H1809)
文摘The applications of carbon ion beam in tumor therapy have attracted more attention in recent years.Monte Carlo simulation is an important approach to obtain accurate radiotherapy parameters. In this work, a400 Me V/u carbon ion beam incident on water phantom was simulated with Gate/Geant4 tools. In methods, the authors set up a carbon ion beam source according to the experiment parameters of Haettner, defined the geometries and materials, set up the physics processes, and designed the means of information collection. In results,the authors obtained the longitudinal dose distribution, the lateral dose distribution, and the relative uncertainty of dose. The dose contributions of all kinds of fragments were calculated detailedly and compared with the Francis results. This work is helpful for people's understanding of the dose distributions produced by carbon ion beam and fragments in water. The simulation method is also significative for radiotherapy treatment planning of carbon ion beam, and it is easy to extend. For obtaining a special result, we may change the particle energy, particle type,target material, target geometry, physics process, detector,etc.