Background:Traditional imaging approaches to keratoconus(KCN)have thus far failed to produce a standardized approach for diagnosis.While many diagnostic modalities and metrics exist,none have proven robust enough to b...Background:Traditional imaging approaches to keratoconus(KCN)have thus far failed to produce a standardized approach for diagnosis.While many diagnostic modalities and metrics exist,none have proven robust enough to be considered a gold standard.This study aims to introduce novel metrics to differentiate between KCN and healthy corneas using three-dimensional(3D)measurements of surface area and volume.Methods:This retrospective observational study examined KCN patients along with healthy control patients between the ages of 20 and 79 years old at the University of Maryland,Baltimore.The selected patients underwent a nine-line raster scan anterior segment optical coherence tomography(AS-OCT).ImageJ was used to determine the central 6 mm of each image and each corneal image was then divided into six 1 mm segments.Free-D software was then used to render the nine different images into a 3D model to calculate corneal surface area and volume.A two-tailed Mann-Whitney test was used to assess statistical significance when comparing these subsets.Results:Thirty-three eyes with KCN,along with 33 healthy control,were enrolled.There were statistically significant differences between the healthy and KCN groups in the metric of anterior corneal surface area(13.927 vs.13.991 mm^(2),P=0.046),posterior corneal surface area(14.045 vs.14.173 mm^(2),P<0.001),and volume(8.430 vs.7.773 mm3,P<0.001)within the central 6 mm.Conclusions:3D corneal models derived from AS-OCT can be used to measure anterior corneal surface area,posterior corneal surface area,and corneal volume.All three parameters are statistically different between corneas with KCN and healthy corneas.Further study and application of these parameters may yield new methodologies for the detection of KCN.展开更多
Polycrystalline CuInS2 (CIS) films were prepared by sulphurization of Cu-In films. The surface morphology and phase composition of the as-grown film, the KCN-etched film, and the annealed KCN-etched film were invest...Polycrystalline CuInS2 (CIS) films were prepared by sulphurization of Cu-In films. The surface morphology and phase composition of the as-grown film, the KCN-etched film, and the annealed KCN-etched film were investigated. During the sulphurization, the secondary CuxS phase segregated on the surface of the as-grown films. To improve the crystalline quality of CuInS2 films, a series of post-grown treatments, such as KCN-etching and vacuum annealing KCN-etched films, were performed on the as-grown films. Both as-grown and post-treated films were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), and energy dispersive spectroscopy (EDS). The results indicated that a CuxS secondary phase segregated on the surface of the as-grown film, which could be removed effectively by KCN etching. After the vacuum annealing treatment, the KCN-etched film had a sphalerite structure with (112) preferred orientation. Meanwhile, the crystalline quality of the CIS film was significantly improved, which provided a novel method to improve the performance of thin film solar cells.展开更多
In this paper,an analytical method based on a chemical reaction between KSCN and sodium dichloroisocyanurate-dihydrate in a buffer system was applied to quantify the total alkaloid in tobacco.The proposed method repla...In this paper,an analytical method based on a chemical reaction between KSCN and sodium dichloroisocyanurate-dihydrate in a buffer system was applied to quantify the total alkaloid in tobacco.The proposed method replaced the No.35 Recommended Method of CORESTA(CRM 35)with the advantage that this method is safer compared to the CRM35 which uses KCN,a highly toxic chemical.In addition,compared to the current national standard method YC/T 468一2013,the buffer solution preparation was optimized to improve the detection efficiency.The validation results indicated that the new method met the test requirements,and the results were consistent with the ones obtained from the CORESTA CRM 35 and the YC/T 468一2013 methods.展开更多
文摘Background:Traditional imaging approaches to keratoconus(KCN)have thus far failed to produce a standardized approach for diagnosis.While many diagnostic modalities and metrics exist,none have proven robust enough to be considered a gold standard.This study aims to introduce novel metrics to differentiate between KCN and healthy corneas using three-dimensional(3D)measurements of surface area and volume.Methods:This retrospective observational study examined KCN patients along with healthy control patients between the ages of 20 and 79 years old at the University of Maryland,Baltimore.The selected patients underwent a nine-line raster scan anterior segment optical coherence tomography(AS-OCT).ImageJ was used to determine the central 6 mm of each image and each corneal image was then divided into six 1 mm segments.Free-D software was then used to render the nine different images into a 3D model to calculate corneal surface area and volume.A two-tailed Mann-Whitney test was used to assess statistical significance when comparing these subsets.Results:Thirty-three eyes with KCN,along with 33 healthy control,were enrolled.There were statistically significant differences between the healthy and KCN groups in the metric of anterior corneal surface area(13.927 vs.13.991 mm^(2),P=0.046),posterior corneal surface area(14.045 vs.14.173 mm^(2),P<0.001),and volume(8.430 vs.7.773 mm3,P<0.001)within the central 6 mm.Conclusions:3D corneal models derived from AS-OCT can be used to measure anterior corneal surface area,posterior corneal surface area,and corneal volume.All three parameters are statistically different between corneas with KCN and healthy corneas.Further study and application of these parameters may yield new methodologies for the detection of KCN.
基金the National High-Tech Research and Development Program of China (No. 2006AA03Z2370)
文摘Polycrystalline CuInS2 (CIS) films were prepared by sulphurization of Cu-In films. The surface morphology and phase composition of the as-grown film, the KCN-etched film, and the annealed KCN-etched film were investigated. During the sulphurization, the secondary CuxS phase segregated on the surface of the as-grown films. To improve the crystalline quality of CuInS2 films, a series of post-grown treatments, such as KCN-etching and vacuum annealing KCN-etched films, were performed on the as-grown films. Both as-grown and post-treated films were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), and energy dispersive spectroscopy (EDS). The results indicated that a CuxS secondary phase segregated on the surface of the as-grown film, which could be removed effectively by KCN etching. After the vacuum annealing treatment, the KCN-etched film had a sphalerite structure with (112) preferred orientation. Meanwhile, the crystalline quality of the CIS film was significantly improved, which provided a novel method to improve the performance of thin film solar cells.
文摘In this paper,an analytical method based on a chemical reaction between KSCN and sodium dichloroisocyanurate-dihydrate in a buffer system was applied to quantify the total alkaloid in tobacco.The proposed method replaced the No.35 Recommended Method of CORESTA(CRM 35)with the advantage that this method is safer compared to the CRM35 which uses KCN,a highly toxic chemical.In addition,compared to the current national standard method YC/T 468一2013,the buffer solution preparation was optimized to improve the detection efficiency.The validation results indicated that the new method met the test requirements,and the results were consistent with the ones obtained from the CORESTA CRM 35 and the YC/T 468一2013 methods.