High-energy photon source(HEPS) is a 6 GeV ultralow emittance storage ring light source to be built in Beijing, China. Both the horizontal and vertical beam sizes of the HEPS storage ring are below 10 lm. It is a chal...High-energy photon source(HEPS) is a 6 GeV ultralow emittance storage ring light source to be built in Beijing, China. Both the horizontal and vertical beam sizes of the HEPS storage ring are below 10 lm. It is a challenge to measure such a small beam size in both directions. To this end, measurement by a Kirkpatrick–Baez(KB) mirror imaging system was evaluated. A test KB system for the Shanghai Synchrotron Radiation Facility storage ring was designed and tested. Two crossed cylindrical mirrors were used to image the dipole source point. Both mirrors can be moved in and out so that the monitor is interchangeable with the original X-ray pinhole monitor. The aberration and point spread function, which would cause image blur, were evaluated. A beam-based calibration scheme was used by varying the beam size with different quadrupole settings and fitting them with the corresponding theoretical values.We updated the original X-ray camera with a new camera having a 5-lm-thick LuAG/Ce scintillator, and the imaging result shows greatly decreased image blur.展开更多
Offering high-brilliance X-ray beams on micrometer length scales,the μSAXS at SSRF BL16 B1 has been established with a KB mirror system for studying small sample volumes,or probing microscopic morphologies.The SAXS m...Offering high-brilliance X-ray beams on micrometer length scales,the μSAXS at SSRF BL16 B1 has been established with a KB mirror system for studying small sample volumes,or probing microscopic morphologies.The SAXS minimum q value is 0.1 nm^-1 with a flux of 1.5×10^10 photons/s.Two position-resolved scanning experimental methods,STXM and CT,are combined with μSAXS.To improve the significant smearing effect in the horizontal direction,an effective and easy-to-use desmearing procedure for two-dimensional SAXS patterns based on blind deconvolution was developed,and the deblurring results demonstrate the good restoration effect for the defocused image.Finally,a bamboo sample was used in the SAXS-CT experiment to illustrate the performance of the μSAXS method.展开更多
文摘High-energy photon source(HEPS) is a 6 GeV ultralow emittance storage ring light source to be built in Beijing, China. Both the horizontal and vertical beam sizes of the HEPS storage ring are below 10 lm. It is a challenge to measure such a small beam size in both directions. To this end, measurement by a Kirkpatrick–Baez(KB) mirror imaging system was evaluated. A test KB system for the Shanghai Synchrotron Radiation Facility storage ring was designed and tested. Two crossed cylindrical mirrors were used to image the dipole source point. Both mirrors can be moved in and out so that the monitor is interchangeable with the original X-ray pinhole monitor. The aberration and point spread function, which would cause image blur, were evaluated. A beam-based calibration scheme was used by varying the beam size with different quadrupole settings and fitting them with the corresponding theoretical values.We updated the original X-ray camera with a new camera having a 5-lm-thick LuAG/Ce scintillator, and the imaging result shows greatly decreased image blur.
基金Supported by National Natural Science Foundation of China(11505278 and 11675253)
文摘Offering high-brilliance X-ray beams on micrometer length scales,the μSAXS at SSRF BL16 B1 has been established with a KB mirror system for studying small sample volumes,or probing microscopic morphologies.The SAXS minimum q value is 0.1 nm^-1 with a flux of 1.5×10^10 photons/s.Two position-resolved scanning experimental methods,STXM and CT,are combined with μSAXS.To improve the significant smearing effect in the horizontal direction,an effective and easy-to-use desmearing procedure for two-dimensional SAXS patterns based on blind deconvolution was developed,and the deblurring results demonstrate the good restoration effect for the defocused image.Finally,a bamboo sample was used in the SAXS-CT experiment to illustrate the performance of the μSAXS method.