期刊文献+
共找到155篇文章
< 1 2 8 >
每页显示 20 50 100
Ionic current rectification in asymmetric nanofluidic devices
1
作者 Yue Zhou Xuewei Liao +2 位作者 Jing Han Tingting Chen Chen Wang 《Chinese Chemical Letters》 SCIE CAS CSCD 2020年第9期2414-2422,共9页
In recent decades,the properties and behaviors of nanofluidic devices have been widely explored in varied subjects such as engineering,physics,chemistry,and biology.Among the rich properties of nanofluidics,ionic curr... In recent decades,the properties and behaviors of nanofluidic devices have been widely explored in varied subjects such as engineering,physics,chemistry,and biology.Among the rich properties of nanofluidics,ionic current rectification(ICR) is a unique phenomenon arising from asymmetric nanofluidic devices with electric double layer(EDL) overlapped.The ICR property is especially useful in applications including energy conversion,mass separation,sea water purification and bioanalysis.In this review,the ICR property in nanofluidics as well as the underlying mechanism is demonstrated.The influencing factors concerning to the ICR property are systematically summarized.The asymmetric geometry as well as the charge distribution is in charge of the ICR behavior occurring in nanofluidic devices.This review is aimed at readers who are interested in the fundamentals of mass transport in nanofluidics in general,as well as those who are willing to apply nanofluidics in various research fields. 展开更多
关键词 Nanofluidics ionic current rectification(ICR) Mass transport Electric double layer(EDL)
原文传递
The Principle of Calibration Using the Ionic Current——A New Calibration Method for Electro-Magnetic Flowmeters
2
作者 Li Bin Sheng Yu (School of Automation) 《Advances in Manufacturing》 SCIE CAS 1998年第2期38-42,共5页
An equivalent relationship between electro magnetic flowmeters (EMFs) and the Hall effect is discussed in principle and three equivalent conclusions about their measuring equations are derived. Thereby,the calibratio... An equivalent relationship between electro magnetic flowmeters (EMFs) and the Hall effect is discussed in principle and three equivalent conclusions about their measuring equations are derived. Thereby,the calibration using the ionic current (CUIC) is introduced to the calibration of EMFs in a special Hall effect system. A basic system with these equations is specially given and discussed for realizing the method. Two key points about CUIC are proved by a simple experiment. 展开更多
关键词 calibration of EMFs equivalent relationship between EMFs and Hall effect ionic current being equivalent to the real flowrate of an EMF
在线阅读 下载PDF
Exact Traveling Wave Solutions of Nano-Ionic Solitons and Nano-Ionic Current of MTs Using the exp(-φ (ξ ))-Expansion Method
3
作者 Emad H. M. Zahran 《Advances in Nanoparticles》 2015年第2期25-36,共12页
In this work, the exp(-φ (ξ )) -expansion method is used for the first time to investigate the exact traveling wave solutions involving parameters of nonlinear evolution equations. When these parameters are taken to... In this work, the exp(-φ (ξ )) -expansion method is used for the first time to investigate the exact traveling wave solutions involving parameters of nonlinear evolution equations. When these parameters are taken to be special values, the solitary wave solutions are derived from the exact traveling wave solutions. The validity and reliability of the method are tested by its applications to Nano-ionic solitons wave’s propagation along microtubules in living cells and Nano-ionic currents of MTs which play an important role in biology. 展开更多
关键词 The exp(-φ )) -Expansion Method Nano-Solitons of ionic Wave’s Propagation along Microtubules in Living Cells Nano-ionic currents of MTS Traveling WAVE SOLUTIONS KINK and Anti KINK WAVE SOLUTIONS
在线阅读 下载PDF
Exact Traveling Wave Solutions for Nano-Solitons of Ionic Waves Propagation along Microtubules in Living Cells and Nano-Ionic Currents of MTs
4
作者 Emad H. M. Zahran 《World Journal of Nano Science and Engineering》 2015年第3期78-87,共10页
In this work, the extended Jacobian elliptic function expansion method is used as the first time to evaluate the exact traveling wave solutions of nonlinear evolution equations. The validity and reliability of the met... In this work, the extended Jacobian elliptic function expansion method is used as the first time to evaluate the exact traveling wave solutions of nonlinear evolution equations. The validity and reliability of the method are tested by its applications to nano-solitons of ionic waves propagation along microtubules in living cells and nano-ionic currents of MTs which play an important role in biology. 展开更多
关键词 Extended Jacobian Elliptic Function Expansion Method Nano-Solitons of ionic WAVES PROPAGATION ALONG MICROTUBULES in Living Cells Nano-ionic currents of MTS Traveling Wave Solutions
在线阅读 下载PDF
Water Dissociation Phenomena on a Bipolar Membrane──Current-voltage Curve in Relation with IonicTransport and Limiting Current Density 被引量:1
5
作者 XU Tong-wen YANG Wei-hua 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2001年第4期457-464,共8页
The water dissociation mechanism on a bipolar membrane under the electrical field was investigated and characterized in terms of ionic transport and limiting current density. It is considered that the depletion layer ... The water dissociation mechanism on a bipolar membrane under the electrical field was investigated and characterized in terms of ionic transport and limiting current density. It is considered that the depletion layer exists at the junction of a bipolar membrane, which is coincided with the viewpoint of the most literatures, but we also consider that the thickness and conductivity of this layer is not only related with the increase of the applied voltage but also with the limiting current density. Below the limiting current density, the thickness of the depletion layer keeps a constant and the conductivity decreases with the increase of the applied voltage; while above the limiting current density, the depletion thickness will increase with the increase of the applied voltage and the conductivity keeps a very low constant. Based on the data reported in the literatures and independent determinations, the limiting current density was calculated and the experimental curves Ⅰ-Ⅴ in the two directions were com 展开更多
关键词 Bipolar membrane Water dissociation ionic transport Limiting current density
在线阅读 下载PDF
Pressure Distribution Induced by Ionic Wind in Needle-to-water Corona Discharge 被引量:2
6
作者 ZHANG Yu LIU Lijuan OUYANG Jiting 《高电压技术》 EI CAS CSCD 北大核心 2013年第9期2187-2192,共6页
The negative DC corona discharge in air at atmospheric pressure was investigated in a needle-to-water system to obtain the pressure distribution of corona ionic wind.The deformation of water surface was measured and t... The negative DC corona discharge in air at atmospheric pressure was investigated in a needle-to-water system to obtain the pressure distribution of corona ionic wind.The deformation of water surface was measured and the distribution of wind pressure over the water surface was calculated.The effects of varying discharge parameters,such as applied voltage,gap spacing,tip radius of needle,and the shape of grounded electrode,on the wind pressure were studied.The measured wind pressure ranges from several Pa to several tens of Pa and up to 33 Pa over a small area;the pressure is comparatively large in the center and decreases quickly outwards.In the experiment system,a higher voltage on a 3 mm gap resulted in a stronger pressure of the ionic wind;around the onset voltage,using a needle with tip radius of 50μm obtained a larger wind pressure than using a needle with 100μm tip radius,but the latter one can produce larger pressure at higher voltages.Plus,the shape of the grounded electrode only influences the wind pressure a little. 展开更多
关键词 压力分布 电晕放电 离子风 水针 起始电压 接地电极 风压力 大气压力
原文传递
A spinal circuit model with an asymmetric cervical-lumbar layout for limb coordination and gait control in quadrupeds
7
作者 Qinghua ZHU Fang HAN Qingyun WANG 《Applied Mathematics and Mechanics(English Edition)》 2025年第8期1433-1450,I0006-I0009,共22页
In quadrupeds,the cervical and lumbar circuits work together to achieve the speed-dependent gait expression.While most studies have focused on how local lumbar circuits regulate limb coordination and gaits,relatively ... In quadrupeds,the cervical and lumbar circuits work together to achieve the speed-dependent gait expression.While most studies have focused on how local lumbar circuits regulate limb coordination and gaits,relatively few studies are known about cervical circuits and even less about locomotor gaits.We use the previously published models by Danner et al.(DANNER,S.M.,SHEVTSOVA,N.A.,FRIGON,A.,and RYBAK,I.A.Computational modeling of spinal circuits controlling limb coordination and gaits in quadrupeds.e Life,6,e31050(2017))as a basis,and modify it by proposing an asymmetric organization of cervical and lumbar circuits.First,the model reproduces the typical speed-dependent gait expression in mice and more biologically appropriate locomotor parameters,including the gallop gait,locomotor frequencies,and limb coordination of the forelimbs.Then,the model replicates the locomotor features regulated by the M-current.The walk frequency increases with the M-current without affecting the interlimb coordination or gaits.Furthermore,the model reveals the interaction mechanism between the brainstem drive and ionic currents in regulating quadrupedal locomotion.Finally,the model demonstrates the dynamical properties of locomotor gaits.Trot and bound are identified as attractor gaits,walk as a semi-attractor gait,and gallop as a transitional gait,with predictable transitions between these gaits.The model suggests that cervical-lumbar circuits are asymmetrically recruited during quadrupedal locomotion,thereby providing new insights into the neural control of speed-dependent gait expression. 展开更多
关键词 locomotor control cervical-lumbar asymmetrical spinal circuit computational modeling ionic current GAIT
在线阅读 下载PDF
Bipolar nanofluidic channel:from rectifier to capacitor
8
作者 Baobei Li Guanghua Du +11 位作者 Hu Zhang Jinlong Guo Wenjing Liu Can Zhao Ruqun Wu Wenchang Zhou Huijun Yao Hongjin Mou Cheng Shen Chenyu Li Muhammad Jahangeer Linyan Fu 《Acta Mechanica Sinica》 2025年第8期14-22,共9页
A systematic understanding of the mechanism in the rectification and capacitance of nanochannels and their regulation with the electrolyte concentration and electrical bias is pivotal for its wide applications to nano... A systematic understanding of the mechanism in the rectification and capacitance of nanochannels and their regulation with the electrolyte concentration and electrical bias is pivotal for its wide applications to nanofluidic electronics,ion separation,energy storage,and molecule sensing.Single unipolar and bipolar cylindrical nanochannels through polymer film were fabricated using single ion bombardment and track etching.Cyclic voltammetry results show that the bipolar nanochannel switches from rectification to capacitance as the electrolyte concentration decreases.Electrochemical impedance spectroscopy revealed that the capacitive impedance fraction in the bipolar nanochannel is regulated by electrolyte concentration and voltage.The switch from rectification to capacitance in the polymer nanochannel is well explained through a fluidic p-n junction model with a variable ion depletion layer regulated by the applied bias voltage,which is supported by the multi-physics simulation using Poisson-Nernst-Planck and Navier-Stokes solution.This work provides a mechanistic insight into the ionic current rectification and ionic capacitance in complex ionic nanochannels and paves the way for biomimetic nanofluidic electronics design. 展开更多
关键词 Bipolar nanochannel Nanofluidic device ionic capacitance ionic current rectification Ion depletion layer
原文传递
基于循环伏安法的热充电超级电容器数值研究
9
作者 卞时刚 孟婷婷 杨理理 《发电技术》 2025年第6期1176-1183,共8页
【目的】热充电超级电容器在储能领域的应用受到电解质离子特性的限制。为探究电解质离子特性对器件电容性能和功率密度的影响,基于循环伏安法测试原理,采用多物理场数值模拟方法构建了热充电超级电容器数值模型。【方法】分析了离子尺... 【目的】热充电超级电容器在储能领域的应用受到电解质离子特性的限制。为探究电解质离子特性对器件电容性能和功率密度的影响,基于循环伏安法测试原理,采用多物理场数值模拟方法构建了热充电超级电容器数值模型。【方法】分析了离子尺寸比、离子类型对电容性能、功率密度的影响,并总结了给定温差下电极固液界面处的阳离子浓度变化规律。【结果】在低扫描速率下,热充电超级电容器的电流密度与比电容随离子尺寸比的增大而减小。此时,功率密度主要受离子尺寸比的影响,其随着离子尺寸比的增大而减小。而在高扫描速率下,功率密度主要受离子类型影响。【结论】该研究提出了电解质离子特性优化策略,对热充电超级电容器的数值建模和理论分析有重要意义。 展开更多
关键词 余热发电技术 超级电容器 循环伏安法 数值模型 离子特性 电流密度 功率密度 电容性能
在线阅读 下载PDF
不同电流类型对电沉积铝镀层微观结构的影响机理
10
作者 滕心跃 刘超男 +2 位作者 张东勋 王振卫 文锋 《核技术》 北大核心 2025年第1期115-121,共7页
电镀铝+热处理扩散工艺是制备阻氚涂层的常用方法,铝镀层表面微观形貌影响后续热处理效果,进而对阻氚性能有着重要影响。在AlCl_(3)-1-乙基-3-甲基咪唑(1-Ethyl-3-methylimidazolium Chloride,EMIC)离子液体中,采用不同工艺参数在316L... 电镀铝+热处理扩散工艺是制备阻氚涂层的常用方法,铝镀层表面微观形貌影响后续热处理效果,进而对阻氚性能有着重要影响。在AlCl_(3)-1-乙基-3-甲基咪唑(1-Ethyl-3-methylimidazolium Chloride,EMIC)离子液体中,采用不同工艺参数在316L不锈钢基体表面制备铝镀层。利用X射线衍射(X-ray Diffraction,XRD)、扫描电子显微镜(Scanning Electron Microscopy,SEM)等手段,分析不同工艺参数对铝镀层相结构及内部微观形貌的影响机理。XRD结果表明:所有镀层成分均为单质铝;SEM结果表明:镀层表面部分晶粒随直流电流密度而增大,较优电流密度范围为10~20 mA·cm^(-2);与直流电沉积工艺相比,单向脉冲电流波形电沉积所得铝镀层厚度最大,双向脉冲电流形成铝镀层晶粒和厚度最小,晶粒大小均匀。主要原因在于,单向脉冲模式下瞬时峰值电流较大,促进镀层晶粒生长,厚度变厚;双向脉冲模式中的反向电流可溶解掉部分镀层,明显抑制镀层内较大晶粒长大,导致所形成镀层晶粒均匀细小。 展开更多
关键词 阻氚涂层 AlCl3-EMIC离子液体 室温电镀铝 电流类型 微观结构
原文传递
LED显示屏“毛毛虫”现象失效分析与机理研究
11
作者 周小霍 冯学亮 +2 位作者 刘兴龙 曾志卫 吴冰冰 《电子质量》 2025年第10期67-71,共5页
发光二极管(LED)灯珠凭借其高效率、长寿命与低成本等优势,已广泛应用于家用显示、新能源车机/车灯及户外大屏等领域。然而,在使用过程中,因吸湿导致的漏电问题已成为影响产品可靠性的行业共性难题。基于LED显示屏的工作原理,结合典型... 发光二极管(LED)灯珠凭借其高效率、长寿命与低成本等优势,已广泛应用于家用显示、新能源车机/车灯及户外大屏等领域。然而,在使用过程中,因吸湿导致的漏电问题已成为影响产品可靠性的行业共性难题。基于LED显示屏的工作原理,结合典型“毛毛虫”失效案例,系统开展失效分析工作:首先,通过万用表、晶体管特性图示仪进行电性能验证,明确漏电现象;其次,借助锁相热红外显微镜、X射线进行无损检测与定位,锁定异常区域;然后,通过切片与扫描电子显微镜观察,在微观层面确认了导电阳极丝的存在,从而完整揭示了因印制电路板离子迁移引发漏电的失效机理与根本原因;最后,提出有针对性的分析方案与管控对策,对于提升电子产品的可靠性与使用寿命具有积极的工程指导意义。 展开更多
关键词 发光二极管 显示屏 漏电 离子迁移 失效分析
在线阅读 下载PDF
Electrophoresis of poly(dT)_(20) through α-hemolysin nanopore in high concentration potassium chloride solution
12
作者 司伟 杨浩杰 +4 位作者 纪安平 李堃 沙菁 刘磊 陈云飞 《Journal of Southeast University(English Edition)》 EI CAS 2016年第4期496-501,共6页
Experiments of poly(dT)20 electrophoresis throughα-hemolysin nanopores were performed to unveil the electrophoretic transport mechanism of DNA through nanopores in high concentration potassium chloride solution. It... Experiments of poly(dT)20 electrophoresis throughα-hemolysin nanopores were performed to unveil the electrophoretic transport mechanism of DNA through nanopores in high concentration potassium chloride solution. It is found that there are two obvious current blockades induced by poly(dT)20 translocation and collision events. Both blockade currents increase linearly with the applied bias voltage. However, the normalized blockade currents are almost kept the same although variable bias voltages are applied. The collision time of poly(dT)20 in the luminal site of the pore remains constant for different voltages. The translocation speed of poly(dT)20through the nanopore decreases with the increase of bias voltage. It is because as the potential increases, the drag force on the homopolymer helps it to crumple into a cluster much easier due to the poor stacking of thymine residues compared with homopolymers consisting of other nucleotides. Molecular dynamics simulations further confirm the experimental results. Increasing the applied bias voltage can slowdown the translocation velocity of the flexible poly(dT)20, which favors increasing the precision of single molecule detection by using nanopores. 展开更多
关键词 NANOPORE transport speed ionic current ELECTROPHORESIS
在线阅读 下载PDF
火花塞离子电流传感器在发动机敲缸探测上的应用 被引量:11
13
作者 吴筱敏 李福明 +1 位作者 蒋德明 王子延 《西安交通大学学报》 EI CAS CSCD 北大核心 2000年第9期25-27,共3页
提出了一种直接利用火花塞作为检测传感器测量发动机爆震的新方法 .通过在火花塞电极两端加偏置电压 ,测量燃烧过程中流经火花塞的离子电流 ,从而判断发动机是否爆震 .在DA4 62 -A四缸汽油机上进行了大量的试验研究 ,采集出了爆震与非... 提出了一种直接利用火花塞作为检测传感器测量发动机爆震的新方法 .通过在火花塞电极两端加偏置电压 ,测量燃烧过程中流经火花塞的离子电流 ,从而判断发动机是否爆震 .在DA4 62 -A四缸汽油机上进行了大量的试验研究 ,采集出了爆震与非爆震时的离子电流信号 ,发现有爆震时会出现一定频率的高频信号叠加在离子电流信号上 .对所采集的信号进行快速傅里叶变换 (FFT) ,确定试验用发动机爆震的特征频域为 1 0~ 1 1kHz .试验结果证明 ,火花塞作为离子电流传感器是探测火花点火发动机爆震的有效便捷方法 . 展开更多
关键词 火花塞 爆震 离子电流传感器 敲缸探测
在线阅读 下载PDF
高压直流双回输电线路合成电场与离子流的计算 被引量:38
14
作者 田冀焕 邹军 +1 位作者 刘杰 袁建生 《电网技术》 EI CSCD 北大核心 2008年第2期61-65,70,共6页
高压直流双回输电线路在我国尚无设计与运行经验。为此,文章对双回直流线路电晕效应产生的离子流与综合电场强度进行了计算,分析了导线不同的布置方式以及线路间距、对地高度、导线分裂数、导线半径等结构参数对地表离子流和场强的影响... 高压直流双回输电线路在我国尚无设计与运行经验。为此,文章对双回直流线路电晕效应产生的离子流与综合电场强度进行了计算,分析了导线不同的布置方式以及线路间距、对地高度、导线分裂数、导线半径等结构参数对地表离子流和场强的影响。结果表明,两回线路上下排布方式的地表合成场强与离子流密度较小;在相同导线尺寸与同等架设高度下,合理排布的双回线路的地表场强与离子流远小于单回线路,且双回线间距越小地表场强与离子流越小;同塔双回线路的电磁环境要优于单回线路。 展开更多
关键词 高压直流(HVDC) 双回输电线路 合成场强 离子流
在线阅读 下载PDF
氧自由基致豚鼠心室肌细胞跨膜电位变化的离子电流基础 被引量:9
15
作者 徐长庆 李玉荣 +4 位作者 杨宝峰 单宏丽 孙可青 李全凤 朱世军 《中国应用生理学杂志》 CAS CSCD 2000年第2期121-124,共4页
目的 :旨在揭示氧自由基参与缺血 /再灌注性心律失常发生的离子电流基础。方法 :采用膜片钳全细胞式记录技术 ,观察H2 O2 ( 1mmol/L)对豚鼠心室肌细胞跨膜电位和相关离子电流的影响。结果 :H2 O2 使豚鼠心肌单细胞的静息电位 (RP)降低 ... 目的 :旨在揭示氧自由基参与缺血 /再灌注性心律失常发生的离子电流基础。方法 :采用膜片钳全细胞式记录技术 ,观察H2 O2 ( 1mmol/L)对豚鼠心室肌细胞跨膜电位和相关离子电流的影响。结果 :H2 O2 使豚鼠心肌单细胞的静息电位 (RP)降低 ,动作电位时程 (APD)显著缩短 ,对动作电位幅度 (APA)和超射 (OS)及钠电流的峰值 (INa)均无明显影响 ;明显抑制内向整流钾电流 (IK1) ,尤其在超极化时 ;增强延迟外向钾电流 (IK) ,尤其快组分 (IKr)增加显著 ,而慢组分 (IKs)增加不十分显著 ;抑制或取消L 型钙电流 (ICa)。结论 :活性氧所致心室细胞跨膜电位的变化具有明显的离子电流基础 。 展开更多
关键词 心肌细胞 跨膜电位 离子电流 氧自由基 心律失常
暂未订购
不同运行方式下特高压直流输电线路的地面电场与离子流分布 被引量:15
16
作者 王毅 孙成秋 +2 位作者 汤涛 郎需军 罗栋梁 《电网技术》 EI CSCD 北大核心 2008年第2期29-33,共5页
以向家坝—上海±800kV特高压直流输电线路工程为背景,针对特高压直流输电线路可能存在的4种运行方式,计算和分析了上述输电线路下方地面电场与离子流密度的分布情况,研究了工程投运后特高压直流输电线路产生的电磁环境问题。结果表... 以向家坝—上海±800kV特高压直流输电线路工程为背景,针对特高压直流输电线路可能存在的4种运行方式,计算和分析了上述输电线路下方地面电场与离子流密度的分布情况,研究了工程投运后特高压直流输电线路产生的电磁环境问题。结果表明:在双极运行方式下,地面场强与离子流密度均满足标准要求;并联导线带有相同极性的高电压,同性排斥作用既加强了地面电场强度,又增加了离子流密度,因此单极–双导线并联大地回线运行方式下的地面场强与离子流密度最大,应在实际工程中尽量避免采取这种运行方式。 展开更多
关键词 特高压直流输电线路 双极运行方式 单极运行方式 电场强度 离子流密度
在线阅读 下载PDF
离子电流法测量CH_4/H_2混合气燃烧火焰传播速度的实验研究 被引量:8
17
作者 刘兵 李春艳 +3 位作者 孙天旗 段浩 高忠权 吴筱敏 《西安交通大学学报》 EI CAS CSCD 北大核心 2015年第1期40-45,共6页
在定容燃烧弹上布置一对测量电极,运用离子电流法、根据燃烧火焰在接触测量电极时刻的离子电流信号值,对不同工况下CH4/空气及其掺氢混合气的平均火焰传播速度进行了计算,并与传统光学纹影法测得的火焰速度进行了对比。结果表明:对于C... 在定容燃烧弹上布置一对测量电极,运用离子电流法、根据燃烧火焰在接触测量电极时刻的离子电流信号值,对不同工况下CH4/空气及其掺氢混合气的平均火焰传播速度进行了计算,并与传统光学纹影法测得的火焰速度进行了对比。结果表明:对于CH4/空气混合气预混燃烧火焰,在过量空气系数分别为0.75、0.8、0.85、0.9、1、1.1时,利用离子电流法测得的火焰传播速度分别为1.714、1.935、2.195、2.250、2.045、1.538 m/s,相对纹影法误差分别为1.32%、2.09%、4.65%、3.48%、3.64%、7.06%;对于过量空气系数为0.8的CH4/H2燃料,在掺氢比为0%-80%(10%递增)的情况下,离子电流法测得的火焰传播速度相对于纹影法的误差均在5%之内。该结果为离子电流法的层流火焰传播速度测量提供了理论、实验依据,测量方法简单易行、快捷准确、可行性高。 展开更多
关键词 火焰传播速度 离子电流 定容燃烧弹 天然气掺氢
在线阅读 下载PDF
干扰及偏置电压对火花塞检测信号影响的试验研究 被引量:6
18
作者 吴筱敏 李福明 余鹏 《内燃机工程》 EI CAS CSCD 北大核心 2001年第4期55-57,61,共4页
研究了在用火花塞作为传感器直接测量发动机燃烧状态的检测电路中 ,各种干扰以及电路中所加偏置电压对检测信号的影响。对由火花点火的高频信号和交流工频信号所产生的干扰进行了试验研究 ,提出了具体的解决措施和方案 ;另外在研究中还... 研究了在用火花塞作为传感器直接测量发动机燃烧状态的检测电路中 ,各种干扰以及电路中所加偏置电压对检测信号的影响。对由火花点火的高频信号和交流工频信号所产生的干扰进行了试验研究 ,提出了具体的解决措施和方案 ;另外在研究中还发现 ,当偏置电压不同时 ,通过火花塞所产生的离子电流的幅值和持续时间不同 ,在检测信号中出现单峰和双峰现象 ,由点火所产生的离子电流信号与偏置电压的值关系较大 ,而燃烧后期所产生的离子电流信号与缸内的压力温度有直接关系 ;通过对DA4 6 2 A型发动机的试验研究 ,获得了较为理想的火花塞检测电路和离子电流信号曲线 ,为用火花塞作为传感器实现汽油发动机缸内燃烧信号的检测奠定了试验研究基础。 展开更多
关键词 火花塞 离子电流 干扰 偏置电压 汽车 发动机 检测信号 试验研究
在线阅读 下载PDF
新生大鼠心肌细胞培养及电生理特性观察 被引量:5
19
作者 张颖 郑燕倩 +3 位作者 王红卫 杨智昉 刘远谋 李慈珍 《上海交通大学学报(医学版)》 CAS CSCD 北大核心 2007年第4期398-400,414,共4页
目的应用原代细胞培养技术,以获取大量具有正常电生理特性的心肌细胞。方法用胶原酶溶液处理1 d龄SD大鼠的心脏,差速贴壁法纯化获得的单个心肌细胞,CO2培养箱中培养8 d后,以膜片钳技术记录心肌细胞的动作电位和各跨膜离子流。结果细胞... 目的应用原代细胞培养技术,以获取大量具有正常电生理特性的心肌细胞。方法用胶原酶溶液处理1 d龄SD大鼠的心脏,差速贴壁法纯化获得的单个心肌细胞,CO2培养箱中培养8 d后,以膜片钳技术记录心肌细胞的动作电位和各跨膜离子流。结果细胞培养中,改进了酶溶液的成分、浓度和经典的差速贴壁法作用时间,获得了大量的高纯度单个心肌细胞。在此细胞上,采用电流钳技术,可引导出心室肌动作电位。运用心肌细胞离子通道的电压依赖性和特异阻断剂,在不同的钳制电位和指令电位下,可记录到INa,ICa,Ito,IK等多种离子流。结论改进的细胞培养技术可获得大量的具有正常电生理特性的心肌细胞。 展开更多
关键词 心肌细胞 细胞培养 膜片钳 离子流
在线阅读 下载PDF
一种新型发动机失火检测方法的探讨 被引量:14
20
作者 汪映 吴筱敏 关勇 《内燃机学报》 EI CAS CSCD 北大核心 2002年第1期46-48,共3页
讨论了一种新型的发动机失火检测方法。利用发动机本身的火花塞作为传感器 ,通过外加一个偏置电压 ,在火花塞两极之间形成稳定的离子电流 ,失火时火花塞间离子电流的幅值发生变化。通过监测幅值的变化就可实现失火的检测。试验时通过增... 讨论了一种新型的发动机失火检测方法。利用发动机本身的火花塞作为传感器 ,通过外加一个偏置电压 ,在火花塞两极之间形成稳定的离子电流 ,失火时火花塞间离子电流的幅值发生变化。通过监测幅值的变化就可实现失火的检测。试验时通过增大火花塞间隙、增加火花塞电极间积碳和断电三种方法产生失火 ,同时记录检测离子电流失火信号。试验结果表明用离子电流法检测失火准确 ,直观 ,便捷。 展开更多
关键词 发动机 离子电流法 失火检测方法
在线阅读 下载PDF
上一页 1 2 8 下一页 到第
使用帮助 返回顶部