AIM To investigate the correlation of iodine concentration(IC) generated by spectral computed tomography(CT) with micro-vessel density(MVD) and vascular endothelial growth factor(VEGF) expression in patients with adva...AIM To investigate the correlation of iodine concentration(IC) generated by spectral computed tomography(CT) with micro-vessel density(MVD) and vascular endothelial growth factor(VEGF) expression in patients with advanced gastric carcinoma(GC).METHODS Thirty-four advanced GC patients underwent abdominal enhanced CT in the gemstone spectral imaging mode. The IC of the primary lesion in the arterial phase(AP) and venous phase(VP) were measured, and were then normalized against that in the aorta to provide the normalized IC(nI C). MVD and VEGF were detected by immunohistochemical assays, using CD34 and VEGF-A antibodies, respectively. Correlations of nI C with MVD, VEGF, and clinical-pathological features were analyzed.RESULTS Both nI Cs correlated linearly with MVD and were higher in the primary lesion site than in the normal control site, but were not correlated with VEGF expression. After stratification by clinical-pathological subtypes, nI C-AP showed a statistically significant correlation with MVD, particularly in the group with tumors at stage T4, without nodular involvement, of a mixed Lauren type, where the tumor was located at the antrum site, and occurred in female individuals. nI C-VP showed a positive correlation with MVD in the group with the tumor at stage T4 and above, had nodular involvement, was poorly differentiated, was located at the pylorus site, of a mixed and diffused Lauren subtype, and occurred in male individuals. nI C-AP and nI C-VP showed significant differences in terms of histological differentiation and Lauren subtype.CONCLUSION The IC detected by spectral CT correlated with the MVD. n IC-AP and n IC-VP can reflect angiogenesis in different pathological subgroups of advanced GC.展开更多
Objective This study explored whether thyroglobulin and thyroid disease prevalence rates were higher in pregnant Chinese women with a median urinary iodine concentration of 100-149μg/L,compared with those with a medi...Objective This study explored whether thyroglobulin and thyroid disease prevalence rates were higher in pregnant Chinese women with a median urinary iodine concentration of 100-149μg/L,compared with those with a median urinary iodine concentration of 150-249μg/L maintained through sustainable universal salt iodization.Methods This was a cross-sectional study in which 812 healthy pregnant women were enrolled to collect samples of their household edible salt,urine,and blood during their routine antenatal care in the18 counties in Fujian Province,China.The levels of salt iodine concentration,urinary iodine concentration(UIC),free triiodothyronine(FT3),free thyroid hormone(FT4),thyroid-stimulating hormone(TSH),thyroglobulin(Tg),thyroid peroxidase antibody and thyroglobulin antibody were assessed during the routine antenatal care visits.Results The median UIC(m UIC)in pregnant women was 130.8μg/L(interquartile range=91.5-198.1μg/L)in the counties with an m UIC of 100-149μg/L(Group I),and 172.0μg/L(interquartile range=123.5-244.4μg/L)in the counties with an m UIC of 150-249μg/L(Group II).Goiter prevalence and thyroid nodule detection rates showed no difference between Group I and Group II(P>0.05).Except for FT4 values,the TSH,FT4,FT3,Tg and Tg values>40(μg/L)and the thyroid diseases prevalence rate(TDR)showed no significant differences between Group I and Group II(P>0.05),whether or not iodine supplementation measures were taken.Conclusion Compared with an m UIC of 150-249μg/L,not only there was no difference in thyroid morphology,but also the Tg value,rate of Tg values>40μg/L,and TDR were not higher in pregnant women in the counties with an m UIC of 100-149μg/L achieved through sustainable universal salt iodization in Fujian Province,China.展开更多
Objective: to apply low iodine concentration contrast agent in CTA examination of children with congenital heart disease, and to analyze and study its diagnostic effect. Methods: taking the period from March 2021 to M...Objective: to apply low iodine concentration contrast agent in CTA examination of children with congenital heart disease, and to analyze and study its diagnostic effect. Methods: taking the period from March 2021 to March 2022 as the study period, 80 children with suspected congenital heart disease treated in our hospital were enrolled. The routine iodine contrast agent scanning examination (370mgl/ml) was performed in group A, and the low concentration iodine contrast agent scanning examination (270mgl/ml) was performed in group B. the value of CTA images, the clarity of CTA images, and the uniformity of contrast agents in the two groups were observed and analyzed. Results: there was no significant difference in the CT value of cardiac cavity between the two groups (P > 0.05);There was no significant difference in CT value between the two groups (P > 0.05);The image clarity of group B was higher than that of group A (P;There was no significant difference in the uniformity of contrast medium between the two groups (P > 0.05). Conclusion: the application of CTA with low concentration iodine contrast agent in the diagnosis of children with congenital heart disease can not only reduce the renal burden of children, but also obtain higher definition CTA images, which is worthy of clinical promotion and application.展开更多
Iodine is an essential element for the synthesis of thyroid hormones.Iodine deficiency increases the burden on thyroid function and causes harm to health.The identification of convenient and reliable biomarkers for as...Iodine is an essential element for the synthesis of thyroid hormones.Iodine deficiency increases the burden on thyroid function and causes harm to health.The identification of convenient and reliable biomarkers for assessing iodine nutritional status is essential for evaluating iodine intake.Urinary iodine concentration(UIC)is commonly used for population level iodine status assessment but is less reliable for individuals.A 24-h urine sample is more accurate but difficult to collect[1].Thyroid volume(Tvol)and goiter rate are suitable for evaluating the long-term iodine nutritional status in populations[2].Blood indicator collection is an invasive procedure.展开更多
Objective The aim of this study was to evaluate the impact of the revised Chinese National Standard GB26878-2011 'Iodine Content in Edible Salt' on the iodine status among the Chinese population. Methods In 2011 and...Objective The aim of this study was to evaluate the impact of the revised Chinese National Standard GB26878-2011 'Iodine Content in Edible Salt' on the iodine status among the Chinese population. Methods In 2011 and 2014, the probability proportionate to size sampling(PPS) was used in each Chinese province to obtain the representative data. In each sampling unit, school children aged 8-10 years and pregnant women were selected. Key indicators included urinary iodine concentration(UIC), thyroid volume(TV), and the iodine content in edible household salt. Results The median urinary iodine concentration(MUIC) decreased between 2011 and 2014 from 238.6 to 197.9 μg/L in school-age children. The number of provinces with iodine excess decreased to zero. The proportion of children whose UIC was 〉 300 μg/L was 18.8% and decreased to 11% compared with 29.8% in 2011. There was no significant difference in UIC 〈 50 μg/L between 2014(4.3%) and 2011(3.7%)(P 〉 0.05). The MUIC among pregnant women in 2014 was more concentrated between 110 and 230 μg/L. The goiter rate among children aged 8-10 years was unchanged, both the goiter rate of 2011 and 2014 remaining below 5%, in view of the sustainable elimination of iodine deficiency disorders. Conclusion The National Standard GB26878-2011 'Iodine Content in Edible Salt' that was introduced in March 2012 resulted in an overall improvement in iodine status, reducing the risk of excessive iodine intake in the Chinese population.展开更多
Objective Studies on the relationship between iodine,vitamin A(VA),and vitamin D(VD)and thyroid function are limited.This study aimed to analyze iodine and thyroid-stimulating hormone(TSH)status and their possible rel...Objective Studies on the relationship between iodine,vitamin A(VA),and vitamin D(VD)and thyroid function are limited.This study aimed to analyze iodine and thyroid-stimulating hormone(TSH)status and their possible relationships with VA,VD,and other factors in postpartum women.Methods A total of 1,311 mothers(896 lactating and 415 non-lactating)from Hebei,Zhejiang,and Guangxi provinces were included in this study.The urinary iodine concentration(UIC),TSH,VA,and VD were measured.Results The median UIC of total and lactating participants were 142.00µg/L and 139.95µg/L,respectively.The median TSH,VA,and VD levels in all the participants were 1.89 mIU/L,0.44μg/mL,and 24.04 ng/mL,respectively.No differences in the UIC were found between lactating and non-lactating mothers.UIC and TSH levels were significantly different among the three provinces.The rural UIC was higher than the urban UIC.Obese mothers had a higher UIC and a higher prevalence of excessive TSH.Higher UICs and TSHs levels were observed in both the VD deficiency and insufficiency groups than in the VD-sufficient group.After adjustment,no linear correlation was observed between UIC and VA/VD.No interaction was found between vitamins A/D and UIC on TSH levels.Conclusion The mothers in the present study had no iodine deficiency.Region,area type,BMI,and VD may be related to the iodine status or TSH levels.展开更多
BACKGROUND This is the first documentation of a spontaneous and nonspecific chemical reaction of an iodinated contrast media with ammonium persulfate used in As3+-Ce4+catalytic spectrophotometry for urine iodine conce...BACKGROUND This is the first documentation of a spontaneous and nonspecific chemical reaction of an iodinated contrast media with ammonium persulfate used in As3+-Ce4+catalytic spectrophotometry for urine iodine concentration(UIC)detection.CASE SUMMARY We herein report an incidental case who had a dual source computed tomography examination for papillary thyroid carcinoma diagnosis.Serial spot urine specimens were collected during her hospitalization and were measured by As3+-Ce4+catalytic spectrophotometry on a Beckman Coulter AU5800.The reacted solutions were“brownish”,and the results showed extremely high iodine concentrations despite serial dilutions.The patient claimed no dietary habit of iodized salt or iodine-containing medical history,which strongly pointed to iodinated contrast media(ICM)via intravenous injection.Even with 0.01%ICM,its interruption is still profound on the desired urine iodine reaction with ammonium persulfate,leading to inaccurate UIC and possibly inappropriate treatment.CONCLUSION The following laboratory suggestions should be considered:(1)As3+-Ce4+catalytic spectrophotometry is only suitable for UIC measurement after confirmed ICM renal clearance;(2)A mass spectrometry-based method can be applied as an alternative during the ICM clearance period;and(3)The UIC baseline can be confirmed after ICM injection by consecutive detection for at least 2 mo.展开更多
BACKGROUND Irreversible transmural intestinal necrosis(ITIN)is associated with high mortality rates in patients with acute occlusive mesenteric ischemia(AOMI).Currently,there are not many studies on the use of dual en...BACKGROUND Irreversible transmural intestinal necrosis(ITIN)is associated with high mortality rates in patients with acute occlusive mesenteric ischemia(AOMI).Currently,there are not many studies on the use of dual energy computed tomography(DECT)for evaluating ITIN.AIM To evaluate the diagnostic value of DECT for ITIN in AOMI.METHODS The cases and computed tomography(CT)images of 102 patients with clinically diagnosed AOMI(including 48 ITIN)from January 2012 to January 2022 were retrospectively collected.The CT scans included both multidetector CT and DECT.The raw data from DECT portal-venous phase were reconstructed into 120 kVp mixed energy image,50 keV virtual monoenergetic imaging,and iodine map.Two radiologists independently completed the subjective visual assessment of CT signs related to AOMI.Objective parameters,including the attenuation of the normal and_(lesion)intestinal wall segment(CT50 keV_(lesion),CT_(50 keV normal/lesion))and iodine concentrations(IC_(lesion)and I_(Cnormal/lesion)),were quantified.Furthermore,multivariate logistic regression,receiver operating characteristic curves,and area under the curve(AUC)values were used to evaluate the subjective and objective indicators in predicting ITIN.RESULTS Regarding subjective signs,logistic regression analysis revealed reduced or absent bowel wall enhancement[odds ratio(OR)=5.576,95%confidence interval(CI):1.547-20.093],bowel dilation(OR=11.613,95%CI:3.790-35.586),and parenchymatous organ infarction(OR=4.727,95%CI:1.536-14.551)were independent risk factors for the ITIN.CT subjective signs had a high diagnostic efficacy for ITIN(AUC=0.853).The two DECT objective parameters also exhibited excellent diagnostic value for ITIN,with an AUC of 0.79,a cut-off value of CT50 keV normal/_(lesion)=2.81,and an AUC of 0.777 with a cut-off value of I_(Cnormal/lesion)=2.39.The Delong test showed that there was no significant difference in the efficacy of subjective CT signs and objective DECT parameters(P>0.05).Importantly,we observed that I_(Cnormal/lesion)combined with subjective signs(bowel dilation and parenchymatous organ infarction)had the highest predictive performance(AUC=0.894),sensitivity(100%),and specificity(70.83%),which was statistically different from the AUC of CT subjective signs(P=0.017).CONCLUSION I_(Cnormal/lesion)(DECT-based features)combined with CT subjective signs(bowel dilatation and parenchymatous organ infarction)showed favorable predictive performance for ITIN in AOMI,which may help clinicians develop timely treatment strategies.展开更多
BACKGROUND The level of Ki-67 expression has served as a prognostic factor in gastric cancer.The quantitative parameters based on the novel dual-layer spectral detector computed tomography(DLSDCT)in discriminating the...BACKGROUND The level of Ki-67 expression has served as a prognostic factor in gastric cancer.The quantitative parameters based on the novel dual-layer spectral detector computed tomography(DLSDCT)in discriminating the Ki-67 expression status are unclear.AIM To investigate the diagnostic ability of DLSDCT-derived parameters for Ki-67 expression status in gastric carcinoma(GC).METHODS Dual-phase enhanced abdominal DLSDCT was performed preoperatively in 108 patients with gastric adenocarcinoma.Primary tumor monoenergetic CT attenuation value at 40-100 kilo electron volt(kev),the slope of the spectral curve(λ_(HU)),iodine concentration(IC),normalized IC(nIC),effective atomic number(Z^(eff))and normalized Z^(eff)(nZ^(eff))in the arterial phase(AP)and venous phase(VP)were retrospectively compared between patients with low and high Ki-67 expression in gastric adenocarcinoma.Spearman’s correlation coefficient was used to analyze the association between the above parameters and Ki-67 expression status.Receiver operating characteristic(ROC)curve analysis was performed to compare the diagnostic efficacy of the statistically significant parameters between two groups.RESULTS Thirty-seven and 71 patients were classified as having low and high Ki-67 expression,respectively.CT_(40 kev-VP),CT_(70 kev-VP),CT_(100 kev-VP),and Z^(eff)-related parameters were significantly higher,but IC-related parameters were lower in the group with low Ki-67 expression status than the group with high Ki-67 expression status,and other analyzed parameters showed no statistical difference between the two groups.Spearman’s correlation analysis showed that CT_(40 kev-VP),CT_(70 kev-VP),CT_(100 kev-VP),Z^(eff),and n Z^(eff) exhibited a negative correlation with Ki-67 status,whereas IC and nIC had positive correlation with Ki-67 status.The ROC analysis demonstrated that the multi-variable model of spectral parameters performed well in identifying the Ki-67 status[area under the curve(AUC)=0.967;sensitivity 95.77%;specificity 91.89%)].Nevertheless,the differentiating capabilities of singlevariable model were moderate(AUC value 0.630-0.835).In addition,the nZ_(VP)^(eff) and nIC_(VP)(AUC 0.835 and 0.805)showed better performance than CT_(40 kev-VP),CT_(70 kev-VP) and CT_(100 kev-VP)(AUC 0.630,0.631 and 0.662)in discriminating the Ki-67 status.CONCLUSION Quantitative spectral parameters are feasible to distinguish low and high Ki-67 expression in gastric adenocarcinoma.Z^(eff) and IC may be useful parameters for evaluating the Ki-67 expression.展开更多
<strong>Objectives:</strong> To evaluate the diagnostic performance of the quantitative iodine parameters, including Iodine Concentration (IC), Normalized Iodine Concentration (NIC), and λ<sub>HU<...<strong>Objectives:</strong> To evaluate the diagnostic performance of the quantitative iodine parameters, including Iodine Concentration (IC), Normalized Iodine Concentration (NIC), and λ<sub>HU</sub>, in distinguishing malignant and benign thyroid nodules. <strong>Methods:</strong> Relevant studies were searched from Web of Science, PubMed, Embase, Cochrane Library, China National Knowledge Infrastructure database and other complementary sources from inception to May 20, 2020. Study selection, data extraction, quality assessment, and data analyses were performed following the Cochrane standards and the PRISMA-DTA guideline. <strong>Results: </strong>Eight studies were included (595 patients with 737 thyroid nodules). The pooled sensitivity, specificity and summary diagnostic odds ratio of IC were 79% (95% CI: 69% - 86%), 76% (95% CI: 65% - 84%) and 11 (95% CI: 5 - 27) respectively;those of NIC were 78% (95% CI: 70% - 85%), 80% (95% CI: 74% - 85%) and 15 (95% CI: 9 - 24) respectively;those of λ<sub>HU</sub> were 80% (95% CI: 71% - 87%), 77% (95% CI: 70% - 83%) and 14 (95% CI: 8 - 24) respectively. <strong>Conclusion: </strong>DECT can be a potential evaluation tool for thyroid nodules. The NIC may be the most sensitive iodine parameter and could be comparable between different DECT machines in thyroid nodule assessment.展开更多
基金Supported by the National Natural Science Foundation of China,No.81271573
文摘AIM To investigate the correlation of iodine concentration(IC) generated by spectral computed tomography(CT) with micro-vessel density(MVD) and vascular endothelial growth factor(VEGF) expression in patients with advanced gastric carcinoma(GC).METHODS Thirty-four advanced GC patients underwent abdominal enhanced CT in the gemstone spectral imaging mode. The IC of the primary lesion in the arterial phase(AP) and venous phase(VP) were measured, and were then normalized against that in the aorta to provide the normalized IC(nI C). MVD and VEGF were detected by immunohistochemical assays, using CD34 and VEGF-A antibodies, respectively. Correlations of nI C with MVD, VEGF, and clinical-pathological features were analyzed.RESULTS Both nI Cs correlated linearly with MVD and were higher in the primary lesion site than in the normal control site, but were not correlated with VEGF expression. After stratification by clinical-pathological subtypes, nI C-AP showed a statistically significant correlation with MVD, particularly in the group with tumors at stage T4, without nodular involvement, of a mixed Lauren type, where the tumor was located at the antrum site, and occurred in female individuals. nI C-VP showed a positive correlation with MVD in the group with the tumor at stage T4 and above, had nodular involvement, was poorly differentiated, was located at the pylorus site, of a mixed and diffused Lauren subtype, and occurred in male individuals. nI C-AP and nI C-VP showed significant differences in terms of histological differentiation and Lauren subtype.CONCLUSION The IC detected by spectral CT correlated with the MVD. n IC-AP and n IC-VP can reflect angiogenesis in different pathological subgroups of advanced GC.
基金sponsored by the Fujian Provincial Health Technology Project[2020CXA020]Fujian Provincial Natural Science Funding[2020J01093]Construction of Fujian Provincial Scientific and Technological Innovation Platform[2019Y2001]
文摘Objective This study explored whether thyroglobulin and thyroid disease prevalence rates were higher in pregnant Chinese women with a median urinary iodine concentration of 100-149μg/L,compared with those with a median urinary iodine concentration of 150-249μg/L maintained through sustainable universal salt iodization.Methods This was a cross-sectional study in which 812 healthy pregnant women were enrolled to collect samples of their household edible salt,urine,and blood during their routine antenatal care in the18 counties in Fujian Province,China.The levels of salt iodine concentration,urinary iodine concentration(UIC),free triiodothyronine(FT3),free thyroid hormone(FT4),thyroid-stimulating hormone(TSH),thyroglobulin(Tg),thyroid peroxidase antibody and thyroglobulin antibody were assessed during the routine antenatal care visits.Results The median UIC(m UIC)in pregnant women was 130.8μg/L(interquartile range=91.5-198.1μg/L)in the counties with an m UIC of 100-149μg/L(Group I),and 172.0μg/L(interquartile range=123.5-244.4μg/L)in the counties with an m UIC of 150-249μg/L(Group II).Goiter prevalence and thyroid nodule detection rates showed no difference between Group I and Group II(P>0.05).Except for FT4 values,the TSH,FT4,FT3,Tg and Tg values>40(μg/L)and the thyroid diseases prevalence rate(TDR)showed no significant differences between Group I and Group II(P>0.05),whether or not iodine supplementation measures were taken.Conclusion Compared with an m UIC of 150-249μg/L,not only there was no difference in thyroid morphology,but also the Tg value,rate of Tg values>40μg/L,and TDR were not higher in pregnant women in the counties with an m UIC of 100-149μg/L achieved through sustainable universal salt iodization in Fujian Province,China.
文摘Objective: to apply low iodine concentration contrast agent in CTA examination of children with congenital heart disease, and to analyze and study its diagnostic effect. Methods: taking the period from March 2021 to March 2022 as the study period, 80 children with suspected congenital heart disease treated in our hospital were enrolled. The routine iodine contrast agent scanning examination (370mgl/ml) was performed in group A, and the low concentration iodine contrast agent scanning examination (270mgl/ml) was performed in group B. the value of CTA images, the clarity of CTA images, and the uniformity of contrast agents in the two groups were observed and analyzed. Results: there was no significant difference in the CT value of cardiac cavity between the two groups (P > 0.05);There was no significant difference in CT value between the two groups (P > 0.05);The image clarity of group B was higher than that of group A (P;There was no significant difference in the uniformity of contrast medium between the two groups (P > 0.05). Conclusion: the application of CTA with low concentration iodine contrast agent in the diagnosis of children with congenital heart disease can not only reduce the renal burden of children, but also obtain higher definition CTA images, which is worthy of clinical promotion and application.
基金supported by the National Natural Science Foundation of China(Grant numbers 82204041)Gansu Provincial Science and Technology Program Funded Projects(Grant numbers 22JR11RA184).
文摘Iodine is an essential element for the synthesis of thyroid hormones.Iodine deficiency increases the burden on thyroid function and causes harm to health.The identification of convenient and reliable biomarkers for assessing iodine nutritional status is essential for evaluating iodine intake.Urinary iodine concentration(UIC)is commonly used for population level iodine status assessment but is less reliable for individuals.A 24-h urine sample is more accurate but difficult to collect[1].Thyroid volume(Tvol)and goiter rate are suitable for evaluating the long-term iodine nutritional status in populations[2].Blood indicator collection is an invasive procedure.
文摘Objective The aim of this study was to evaluate the impact of the revised Chinese National Standard GB26878-2011 'Iodine Content in Edible Salt' on the iodine status among the Chinese population. Methods In 2011 and 2014, the probability proportionate to size sampling(PPS) was used in each Chinese province to obtain the representative data. In each sampling unit, school children aged 8-10 years and pregnant women were selected. Key indicators included urinary iodine concentration(UIC), thyroid volume(TV), and the iodine content in edible household salt. Results The median urinary iodine concentration(MUIC) decreased between 2011 and 2014 from 238.6 to 197.9 μg/L in school-age children. The number of provinces with iodine excess decreased to zero. The proportion of children whose UIC was 〉 300 μg/L was 18.8% and decreased to 11% compared with 29.8% in 2011. There was no significant difference in UIC 〈 50 μg/L between 2014(4.3%) and 2011(3.7%)(P 〉 0.05). The MUIC among pregnant women in 2014 was more concentrated between 110 and 230 μg/L. The goiter rate among children aged 8-10 years was unchanged, both the goiter rate of 2011 and 2014 remaining below 5%, in view of the sustainable elimination of iodine deficiency disorders. Conclusion The National Standard GB26878-2011 'Iodine Content in Edible Salt' that was introduced in March 2012 resulted in an overall improvement in iodine status, reducing the risk of excessive iodine intake in the Chinese population.
基金funded by the National Health Commission of People’s Republic of China Medical Reform Major Program‘2016-2017 National Nutrition and Health Surveillance of Children and Lactating Women’Major Public Health Project‘Survey and Evaluation of Iodine Nutrition and Thyroid Diseases of Chinese Population’[131031107000160007].
文摘Objective Studies on the relationship between iodine,vitamin A(VA),and vitamin D(VD)and thyroid function are limited.This study aimed to analyze iodine and thyroid-stimulating hormone(TSH)status and their possible relationships with VA,VD,and other factors in postpartum women.Methods A total of 1,311 mothers(896 lactating and 415 non-lactating)from Hebei,Zhejiang,and Guangxi provinces were included in this study.The urinary iodine concentration(UIC),TSH,VA,and VD were measured.Results The median UIC of total and lactating participants were 142.00µg/L and 139.95µg/L,respectively.The median TSH,VA,and VD levels in all the participants were 1.89 mIU/L,0.44μg/mL,and 24.04 ng/mL,respectively.No differences in the UIC were found between lactating and non-lactating mothers.UIC and TSH levels were significantly different among the three provinces.The rural UIC was higher than the urban UIC.Obese mothers had a higher UIC and a higher prevalence of excessive TSH.Higher UICs and TSHs levels were observed in both the VD deficiency and insufficiency groups than in the VD-sufficient group.After adjustment,no linear correlation was observed between UIC and VA/VD.No interaction was found between vitamins A/D and UIC on TSH levels.Conclusion The mothers in the present study had no iodine deficiency.Region,area type,BMI,and VD may be related to the iodine status or TSH levels.
基金Supported by the“The Six Top Talent Project”of Jiangsu Province,No.WSW-004the Key Laboratory for Laboratory Medicine of Jiangsu Province of China,No.ZDXKB2016005。
文摘BACKGROUND This is the first documentation of a spontaneous and nonspecific chemical reaction of an iodinated contrast media with ammonium persulfate used in As3+-Ce4+catalytic spectrophotometry for urine iodine concentration(UIC)detection.CASE SUMMARY We herein report an incidental case who had a dual source computed tomography examination for papillary thyroid carcinoma diagnosis.Serial spot urine specimens were collected during her hospitalization and were measured by As3+-Ce4+catalytic spectrophotometry on a Beckman Coulter AU5800.The reacted solutions were“brownish”,and the results showed extremely high iodine concentrations despite serial dilutions.The patient claimed no dietary habit of iodized salt or iodine-containing medical history,which strongly pointed to iodinated contrast media(ICM)via intravenous injection.Even with 0.01%ICM,its interruption is still profound on the desired urine iodine reaction with ammonium persulfate,leading to inaccurate UIC and possibly inappropriate treatment.CONCLUSION The following laboratory suggestions should be considered:(1)As3+-Ce4+catalytic spectrophotometry is only suitable for UIC measurement after confirmed ICM renal clearance;(2)A mass spectrometry-based method can be applied as an alternative during the ICM clearance period;and(3)The UIC baseline can be confirmed after ICM injection by consecutive detection for at least 2 mo.
基金Supported by The Project of Nantong City Health Committee,No.MS2023027 and WKZL2018017The“333”Talent Funding Project of Jiangsu Province,No.BRA2020198+1 种基金The Project of Jiangsu Provincial Health Commission,No.ZD2021059The Youth Research Fund of Nantong Municipal Health Commission,No.QNZ2023027.
文摘BACKGROUND Irreversible transmural intestinal necrosis(ITIN)is associated with high mortality rates in patients with acute occlusive mesenteric ischemia(AOMI).Currently,there are not many studies on the use of dual energy computed tomography(DECT)for evaluating ITIN.AIM To evaluate the diagnostic value of DECT for ITIN in AOMI.METHODS The cases and computed tomography(CT)images of 102 patients with clinically diagnosed AOMI(including 48 ITIN)from January 2012 to January 2022 were retrospectively collected.The CT scans included both multidetector CT and DECT.The raw data from DECT portal-venous phase were reconstructed into 120 kVp mixed energy image,50 keV virtual monoenergetic imaging,and iodine map.Two radiologists independently completed the subjective visual assessment of CT signs related to AOMI.Objective parameters,including the attenuation of the normal and_(lesion)intestinal wall segment(CT50 keV_(lesion),CT_(50 keV normal/lesion))and iodine concentrations(IC_(lesion)and I_(Cnormal/lesion)),were quantified.Furthermore,multivariate logistic regression,receiver operating characteristic curves,and area under the curve(AUC)values were used to evaluate the subjective and objective indicators in predicting ITIN.RESULTS Regarding subjective signs,logistic regression analysis revealed reduced or absent bowel wall enhancement[odds ratio(OR)=5.576,95%confidence interval(CI):1.547-20.093],bowel dilation(OR=11.613,95%CI:3.790-35.586),and parenchymatous organ infarction(OR=4.727,95%CI:1.536-14.551)were independent risk factors for the ITIN.CT subjective signs had a high diagnostic efficacy for ITIN(AUC=0.853).The two DECT objective parameters also exhibited excellent diagnostic value for ITIN,with an AUC of 0.79,a cut-off value of CT50 keV normal/_(lesion)=2.81,and an AUC of 0.777 with a cut-off value of I_(Cnormal/lesion)=2.39.The Delong test showed that there was no significant difference in the efficacy of subjective CT signs and objective DECT parameters(P>0.05).Importantly,we observed that I_(Cnormal/lesion)combined with subjective signs(bowel dilation and parenchymatous organ infarction)had the highest predictive performance(AUC=0.894),sensitivity(100%),and specificity(70.83%),which was statistically different from the AUC of CT subjective signs(P=0.017).CONCLUSION I_(Cnormal/lesion)(DECT-based features)combined with CT subjective signs(bowel dilatation and parenchymatous organ infarction)showed favorable predictive performance for ITIN in AOMI,which may help clinicians develop timely treatment strategies.
文摘BACKGROUND The level of Ki-67 expression has served as a prognostic factor in gastric cancer.The quantitative parameters based on the novel dual-layer spectral detector computed tomography(DLSDCT)in discriminating the Ki-67 expression status are unclear.AIM To investigate the diagnostic ability of DLSDCT-derived parameters for Ki-67 expression status in gastric carcinoma(GC).METHODS Dual-phase enhanced abdominal DLSDCT was performed preoperatively in 108 patients with gastric adenocarcinoma.Primary tumor monoenergetic CT attenuation value at 40-100 kilo electron volt(kev),the slope of the spectral curve(λ_(HU)),iodine concentration(IC),normalized IC(nIC),effective atomic number(Z^(eff))and normalized Z^(eff)(nZ^(eff))in the arterial phase(AP)and venous phase(VP)were retrospectively compared between patients with low and high Ki-67 expression in gastric adenocarcinoma.Spearman’s correlation coefficient was used to analyze the association between the above parameters and Ki-67 expression status.Receiver operating characteristic(ROC)curve analysis was performed to compare the diagnostic efficacy of the statistically significant parameters between two groups.RESULTS Thirty-seven and 71 patients were classified as having low and high Ki-67 expression,respectively.CT_(40 kev-VP),CT_(70 kev-VP),CT_(100 kev-VP),and Z^(eff)-related parameters were significantly higher,but IC-related parameters were lower in the group with low Ki-67 expression status than the group with high Ki-67 expression status,and other analyzed parameters showed no statistical difference between the two groups.Spearman’s correlation analysis showed that CT_(40 kev-VP),CT_(70 kev-VP),CT_(100 kev-VP),Z^(eff),and n Z^(eff) exhibited a negative correlation with Ki-67 status,whereas IC and nIC had positive correlation with Ki-67 status.The ROC analysis demonstrated that the multi-variable model of spectral parameters performed well in identifying the Ki-67 status[area under the curve(AUC)=0.967;sensitivity 95.77%;specificity 91.89%)].Nevertheless,the differentiating capabilities of singlevariable model were moderate(AUC value 0.630-0.835).In addition,the nZ_(VP)^(eff) and nIC_(VP)(AUC 0.835 and 0.805)showed better performance than CT_(40 kev-VP),CT_(70 kev-VP) and CT_(100 kev-VP)(AUC 0.630,0.631 and 0.662)in discriminating the Ki-67 status.CONCLUSION Quantitative spectral parameters are feasible to distinguish low and high Ki-67 expression in gastric adenocarcinoma.Z^(eff) and IC may be useful parameters for evaluating the Ki-67 expression.
文摘<strong>Objectives:</strong> To evaluate the diagnostic performance of the quantitative iodine parameters, including Iodine Concentration (IC), Normalized Iodine Concentration (NIC), and λ<sub>HU</sub>, in distinguishing malignant and benign thyroid nodules. <strong>Methods:</strong> Relevant studies were searched from Web of Science, PubMed, Embase, Cochrane Library, China National Knowledge Infrastructure database and other complementary sources from inception to May 20, 2020. Study selection, data extraction, quality assessment, and data analyses were performed following the Cochrane standards and the PRISMA-DTA guideline. <strong>Results: </strong>Eight studies were included (595 patients with 737 thyroid nodules). The pooled sensitivity, specificity and summary diagnostic odds ratio of IC were 79% (95% CI: 69% - 86%), 76% (95% CI: 65% - 84%) and 11 (95% CI: 5 - 27) respectively;those of NIC were 78% (95% CI: 70% - 85%), 80% (95% CI: 74% - 85%) and 15 (95% CI: 9 - 24) respectively;those of λ<sub>HU</sub> were 80% (95% CI: 71% - 87%), 77% (95% CI: 70% - 83%) and 14 (95% CI: 8 - 24) respectively. <strong>Conclusion: </strong>DECT can be a potential evaluation tool for thyroid nodules. The NIC may be the most sensitive iodine parameter and could be comparable between different DECT machines in thyroid nodule assessment.