期刊文献+
共找到976篇文章
< 1 2 49 >
每页显示 20 50 100
Robust current tracking control for three-phase grid-connected inverters with LCL filter
1
作者 LIU Wei WU Ben +2 位作者 SUN Wei-jie XUE Ying CAI Feng-huang 《控制理论与应用》 北大核心 2026年第1期41-51,共11页
This article investigates the robust current tracking control problem of three-phase grid-connected inverters with LCL filter under external disturbance by a dynamic state feedback control method.First,this paper cons... This article investigates the robust current tracking control problem of three-phase grid-connected inverters with LCL filter under external disturbance by a dynamic state feedback control method.First,this paper constructs an internal model to learn the information of the states and input of the grid-connected inverter under steady state.Second,by utilizing the internal model principle,the paper turns the tracking control problem into the robust stabilization control problem based on some appropriate coordinate transformations.Then,The paper designs a dynamics state feedback control law to deal with this robust stabilization problem,and thus the solution of the robust current tracking control problem of three-phase grid-connected inverters can be obtained.This control method can ensure the asymptotic stability of the closedloop system.Finally,the paper illustrates the effectiveness of the proposed control approach through several groups of simulations,and compares it with the feedforward control method to verify the robustness of the proposed control method to uncertain parameters. 展开更多
关键词 grid-connected inverter internal model principle current tracking disturbance suppression robust control
在线阅读 下载PDF
Characteristics of gallium oxide nMOSFET inverter
2
作者 Yixin Zhang Haifeng Chen +4 位作者 Zijie Ding Yuduo Zhang Qin Lu Xiangtai Liu Yunhe Guan 《Journal of Semiconductors》 2026年第2期45-50,共6页
β-Ga_(2)O_(3) MOS inverter should play a crucial role in β-Ga_(2)O_(3) electronic circuits. Enhancement-mode(E-mode) MOSFET was fabricated based on β-Ga_(2)O_(3) film grown by atomic layer deposition technology, an... β-Ga_(2)O_(3) MOS inverter should play a crucial role in β-Ga_(2)O_(3) electronic circuits. Enhancement-mode(E-mode) MOSFET was fabricated based on β-Ga_(2)O_(3) film grown by atomic layer deposition technology, and the β-Ga_(2)O_(3) inverter was further monolithically integrated on this basis. The β-Ga_(2)O_(3) n MOSFET exhibits excellent electrical characteristics with an on/off current ratio reaching 10^(5). The logic inverter shows outstanding voltage inversion characteristics under low-frequency from 1 to 400 Hz operation. As the frequency continues to increase to 10 K, the reverse characteristic becomes worse due to parasitic capacitance induced by processes, and the difference between the highest and lowest values of VOUT has an exponential decay relationship with the frequency. This paper provides the practice for the development of β-Ga_(2)O_(3)-based circuits. 展开更多
关键词 ultra-wide bandgap Ga_(2)O_(3) MOSFET inverter
在线阅读 下载PDF
Robust Sensor—Less PR Controller Design for 15-PUC Multilevel Inverter Topology with Low Voltage Stress for Renewable Energy Applications
3
作者 K.Naga Venkata Siva Damodhar Reddy +3 位作者 P.Krishna Murthy Kiran Kumar Pulamolu M.Dharani T.Venkatakrishnamoorthy 《Energy Engineering》 2026年第1期221-242,共22页
Conventional multilevel inverters often suffer from high harmonic distortion and increased design complexity due to the need for numerous power semiconductor components,particularly at elevated voltage levels.Addressi... Conventional multilevel inverters often suffer from high harmonic distortion and increased design complexity due to the need for numerous power semiconductor components,particularly at elevated voltage levels.Addressing these shortcomings,thiswork presents a robust 15-level PackedUCell(PUC)inverter topology designed for renewable energy and grid-connected applications.The proposed systemintegrates a sensor less proportional-resonant(PR)controller with an advanced carrier-based pulse width modulation scheme.This approach efficiently balances capacitor voltage,minimizes steady-state error,and strongly suppresses both zero and third-order harmonics resulting in reduced total harmonic distortion and enhanced voltage regulation.Additionally,a novel switching algorithm simplifies the design and implementation,further lowering voltage stress across switches.Extensive simulation results validate the performance under various resistive and resistive-inductive load conditions,demonstrating compliance with IEEE-519 THD standards and robust operation under dynamic changes.The proposed sensorless PR-controlled 15-PUC inverter thus offers a compelling,cost-effective solution for efficient power conversion in next-generation renewable energy systems. 展开更多
关键词 PUC packed U cell MLI multilevel inverter SLC sensorless controller PR proportional resonant controller PD phase disposition THD total harmonic distortion
在线阅读 下载PDF
Novel Inverter-Fed Motor Drive System With Common-Mode Voltage Suppression and End-Surge Slew Rate Suppression Function
4
作者 Bo Gao Shunan Yuan +2 位作者 Binglei Cao Kai Liu Guangning Wu 《High Voltage》 2025年第6期1474-1485,共12页
Electric locomotives on the horizon will integrate SiC inverters,promising quicker switching and lower losses than traditional setups.However,in addition to the steep rising edge,the inverter-fed motor drive system fa... Electric locomotives on the horizon will integrate SiC inverters,promising quicker switching and lower losses than traditional setups.However,in addition to the steep rising edge,the inverter-fed motor drive system faces challenges such as high common-mode voltage(CMV)and high motor terminal surge voltage swing rate(dv/dt).To tackle these hurdles,this paper proposes a novel tailored traction control system for three-phase locomotive motors.This innovative strategy utilises nearstate space vector pulse width modulation(NSVPWM),selectively removing space vectors with high CMV to generate modulation signals.Complemented by a slew rate capacitor configuration,the aim is to reduce CMV while effectively suppressing motor-side voltage slew rate.To validate this approach,experimental waveforms from on-site inverter-fed motor drive systems have been analysed to derive high-frequency parameters of long-line cables and variable frequency motors to mimic real locomotive operating conditions better.Through experimental research and comparative simulations against traditional methods,this study reveals a significant 33.3%reduction in CMV compared to traditional systems.Furthermore,it achieves an impressive decrease in the rise/fall slope,down to 86.6%,while ensuring nearly zero electrical power consumption. 展开更多
关键词 nearstate space vector pulse width m sic inverterspromising end surge slew rate suppression traction control system common mode voltage suppression electric locomotives novel inverter fed motor drive system SiC inverters
在线阅读 下载PDF
Complementary inverter based on ZnO thin-film transistors 被引量:1
5
作者 Dunan Hu Genyuan Yu +2 位作者 Ruqi Yang Honglie Lin Jianguo Lu 《Journal of Semiconductors》 2025年第6期106-110,共5页
Complementary inverter is the basic unit for logic circuits,but the inverters based on full oxide thin-film transistors(TFTs)are still very limited.The next challenge is to realize complementary inverters using homoge... Complementary inverter is the basic unit for logic circuits,but the inverters based on full oxide thin-film transistors(TFTs)are still very limited.The next challenge is to realize complementary inverters using homogeneous oxide semiconduc-tors.Herein,we propose the design of complementary inverter based on full ZnO TFTs.Li-N dual-doped ZnO(ZnO:(Li,N))acts as the p-type channel and Al-doped ZnO(ZnO:Al)serves as the n-type channel for fabrication of TFTs,and then the complemen-tary inverter is produced with p-and n-type ZnO TFTs.The homogeneous ZnO-based complementary inverter has typical volt-age transfer characteristics with the voltage gain of 13.34 at the supply voltage of 40 V.This work may open the door for the development of oxide complementary inverters for logic circuits. 展开更多
关键词 complementary inverter thin-film transistor ZNO n-type channel p-type channel
在线阅读 下载PDF
Moving Towards the Reliability-oriented Design of Hairpin Winding for EV Traction Machines Driven by SiC Inverter 被引量:1
6
作者 Xiaowei Ju Yue Zhang +2 位作者 Zhiwei Xue Yuan Cheng Shumei Cui 《CES Transactions on Electrical Machines and Systems》 2025年第1期26-35,共10页
With the development of high-frequency and highvoltagetraction machines(TM)incorporating hairpin windings(HW)and SiC inverters for electric vehicles(EV),both theinterturn voltage stress and temperature within HW are r... With the development of high-frequency and highvoltagetraction machines(TM)incorporating hairpin windings(HW)and SiC inverters for electric vehicles(EV),both theinterturn voltage stress and temperature within HW are rising,increasing the risk of partial discharge(PD),and presentingsignificant challenges to insulation safety.Therefore,this paperaddresses this issue and proposes potential solutions.Firstly,thepaper examines an 8-pole,48-slot,6-layer HW TM to highlightthe unique characteristics of this winding structure,and explainsthe uneven distribution of interturn voltage stress andtemperature.Subsequently,a high-frequency equivalent circuitmodel of the HW TM prototype is developed.The error ofsimulation and experiment is only 5.7%,which proves theaccuracy of the model.Then,an improved HW scheme isproposed to lower the maximum voltage stress by 29.3%.Furthermore,the temperature distribution of HW TM isanalyzed to facilitate a detailed examination of the impact oftemperature on insulation PD.Finally,the partial dischargeinception voltage(PDIV)of interturn insulation,consideringtemperature effects,is calculated and verified throughexperiment.The paper proposes a reliability-oriented designmethod and process for HW TM.It demonstrates that thereliability-oriented design can achieve PD-free performance inthe design stage of HW. 展开更多
关键词 Hairpin winding INSULATION Electric-thermal stress Partial discharge SiC inverter
在线阅读 下载PDF
Fault Diagnosis Method for Photovoltaic Grid-Connected Inverters Based on MPA-VMD-PSO BiLSTM 被引量:1
7
作者 Jingxian Ni Chaomeng Wang +2 位作者 Shiqi Sun Yuxuan Sun Gang Ma 《Energy Engineering》 2025年第9期3719-3736,共18页
To improve the fault diagnosis accuracy of a PV grid-connected inverter,a PV grid-connected inverter data diagnosis method based on MPA-VMD-PSO-BiLSTM is proposed.Firstly,unlike the traditional VMD algorithm which rel... To improve the fault diagnosis accuracy of a PV grid-connected inverter,a PV grid-connected inverter data diagnosis method based on MPA-VMD-PSO-BiLSTM is proposed.Firstly,unlike the traditional VMD algorithm which relies on manual experience to set parameters(e.g.,noise tolerance,penalty parameter,number of decompositions),this paper achieves adaptive optimization of parameters through MPA algorithmto avoid the problemof feature information loss caused by manual parameter tuning,and adopts the improved VMD algorithm for feature extraction of DC-side voltage data signals of PV-grid-connected inverters;and then,adopts the PSO algorithm for theThen,the PSO algorithm is used to optimize the optimal batch size,the number of nodes in the hidden layer and the learning rate of the BiLSTM network,which significantly improves the model’s ability to capture the long-term dependent features of the PV inverter’s timing signals,to construct the PV grid-connected inverter prediction model of PSO-BiLSTM,and predict the capacitance value of the PVgrid-connected inverter.Finally,diagnostic experiments are carried out based on the expected capacitance value and the capacitance failure criterion.The results showthat compared with the traditional VMD algorithm,the MPA-optimised VMD improves the signal-to-noise ratio(SNR)of the signal decomposition from 28.5 to 33.2 dB(16.5%improvement).After combining with the PSO-BiLSTM model,the mean absolute percentage error(MAPE)of the fault diagnosis is reduced to 1.31%,and the coefficient of determination(R2)is up to 0.99.It is concluded that the present method has excellent diagnostic performance of PV grid-connected inverter data signals and effectively improves the accuracy of PV grid-connected inverter diagnosis. 展开更多
关键词 Photovoltaic grid connection inverterS signal diagnostics MPA algorithm VMD algorithm BiLSTM network
在线阅读 下载PDF
Grid-Connected/Islanded Switching Control Strategy for Photovoltaic Storage Hybrid Inverters Based on Modified Chimpanzee Optimization Algorithm
8
作者 Chao Zhou Narisu Wang +1 位作者 Fuyin Ni Wenchao Zhang 《Energy Engineering》 EI 2025年第1期265-284,共20页
Uneven power distribution,transient voltage,and frequency deviations are observed in the photovoltaic storage hybrid inverter during the switching between grid-connected and island modes.In response to these issues,th... Uneven power distribution,transient voltage,and frequency deviations are observed in the photovoltaic storage hybrid inverter during the switching between grid-connected and island modes.In response to these issues,this paper proposes a grid-connected/island switching control strategy for photovoltaic storage hybrid inverters based on the modified chimpanzee optimization algorithm.The proposed strategy incorporates coupling compensation and power differentiation elements based on the traditional droop control.Then,it combines the angular frequency and voltage amplitude adjustments provided by the phase-locked loop-free pre-synchronization control strategy.Precise pre-synchronization is achieved by regulating the virtual current to zero and aligning the photovoltaic storage hybrid inverter with the grid voltage.Additionally,two novel operators,learning and emotional behaviors are introduced to enhance the optimization precision of the chimpanzee algorithm.These operators ensure high-precision and high-reliability optimization of the droop control parameters for photovoltaic storage hybrid inverters.A Simulink model was constructed for simulation analysis,which validated the optimized control strategy’s ability to evenly distribute power under load transients.This strategy effectively mitigated transient voltage and current surges during mode transitions.Consequently,seamless and efficient switching between gridconnected and island modes was achieved for the photovoltaic storage hybrid inverter.The enhanced energy utilization efficiency,in turn,offers robust technical support for grid stability. 展开更多
关键词 Photovoltaic storage hybrid inverters modified chimpanzee optimization algorithm droop control seamless switching
在线阅读 下载PDF
Fault Diagnosis Method for Open-circuit Faults in NPC Three-level Inverter based on WKCNN
9
作者 Guozheng Zhang Menghui Li +1 位作者 Xin Gu Wei Chen 《CES Transactions on Electrical Machines and Systems》 2025年第2期234-245,共12页
With the increasing demand for high reliability and availability in power conversion equipment within power electronics systems,the fault diagnosis of neutral-point-clamped(NPC) three-level inverters has garnered wide... With the increasing demand for high reliability and availability in power conversion equipment within power electronics systems,the fault diagnosis of neutral-point-clamped(NPC) three-level inverters has garnered widespread attention.To address the challenges of fault feature extraction,this article proposes an end-to-end diagnostic approach based on a wavelet kernel convolutional neural network (WKCNN),capable of extracting multi-scale features from current signals to significantly enhance diagnostic accuracy.This method directly uses raw three-phase current signals as input,applying wavelet kernel convolution to automatically capture frequency-domain fault features,combined with a Softmax classifier optimized by the Adam algorithm to achieve fault diagnosis for NPC threelevel inverters.Experimental results under various operating conditions demonstrate that this approach maintains robust diagnostic accuracy across multiple fault scenarios,with comparative analysis further confirming its advantages in diagnostic efficiency and performance over traditional machine learning and other deep learning methods. 展开更多
关键词 NPC three-level inverter Open-circuit fault Wavelet transform Convolutional neural network END-TO-END
在线阅读 下载PDF
Fault-Tolerant Control of Current Measurement Circuits for Three-Phase Grid-Connected Inverters
10
作者 Fatma Ben Youssef Ahlem Ben Youssef +1 位作者 Mohamed Naoui Lassaad Sbita 《Journal of Dynamics, Monitoring and Diagnostics》 2025年第4期308-317,共10页
Three-phase grid-connected inverters(GCIs)are essential components in distributed generation systems,where the accuracy of current measurement circuits is fundamental for reliable closed-loop operation.Nevertheless,th... Three-phase grid-connected inverters(GCIs)are essential components in distributed generation systems,where the accuracy of current measurement circuits is fundamental for reliable closed-loop operation.Nevertheless,the presence of a DC offset in the measured current can disrupt the regulation of grid currents and significantly degrade system performance.In this work,a fault-tolerant control approach is introduced to counteract the impact of such offset faults through a dedicated current compensation mechanism.The proposed solution is built around two main stages:(i)detecting and isolating DC offset faults that may appear in one or multiple phases of the measured grid currents,and(ii)estimating the fault magnitude and reconstructing the corrected current signal.The offset magnitude is obtained analytically by examining the grid current projected onto the synchronous d-axis at the grid angular frequency,eliminating the need for any additional sensing hardware.Simulation and experimental investigations conducted under several fault scenarios confirm the robustness of the proposed strategy and highlight significant improvements in detection speed and diagnostic accuracy. 展开更多
关键词 fault detection grid-connected inverter fault isolation fault-tolerant control sensing circuit
在线阅读 下载PDF
Power Balance Control Strategy of Cascaded H-Bridge Multilevel Inverter Based on Improved Harmonic Injection
11
作者 Feng Zhao Haonan Xu +1 位作者 Xiaoqiang Chen Ying Wang 《Energy Engineering》 2025年第12期4987-5000,共14页
The cascaded H-bridge(CHB)multilevel inverter has become one of the most widely used PV inverter topologies due to its high voltage processing capability and high quality output power.Grid-connected PV system due to e... The cascaded H-bridge(CHB)multilevel inverter has become one of the most widely used PV inverter topologies due to its high voltage processing capability and high quality output power.Grid-connected PV system due to external conditions such as PV panel shading,PV component damage,can lead to PV output power imbalance,triggering the system over-modulation phenomenon,which in turn leads to grid-connected current waveform distortion.To this end,an improved power balance control strategy is proposed in this paper.Firstly,according to the different modulation ratios of each H-bridge module,a suitable harmonic injection method is used to keep the peak value of the modulating waveform always at 1;then an inverse triangular trapezoidal waveform is injected to optimize the modulating waveform,which further improves the output voltage waveform,reduces the THD value of the grid-connected currents,and maintains the stability of power inside the CHB system.Purpose.Simulation verifies the effectiveness and feasibility of this power balance control strategy. 展开更多
关键词 Cascaded H-bridge inverter harmonic injection inverse triangular trapezoidal waveform power balance control
在线阅读 下载PDF
Integrated paralleling of NPC inverters with suppressed circulating current for high-power renewable energy conversion
12
作者 Weiwei Li Guoxiang Hua +1 位作者 Xing Huang Xueguang Zhang 《Global Energy Interconnection》 2025年第1期134-142,共9页
The development of renewable energy power generation for carbon neutrality and energy transition has been increasing worldwide,leading to an increasing demand for high-power conversion.Compared with traditional interl... The development of renewable energy power generation for carbon neutrality and energy transition has been increasing worldwide,leading to an increasing demand for high-power conversion.Compared with traditional interleaved paralleling,the integrated paralleling of three-level inverters can further reduce the output harmonics.Moreover,a well-designed switching sequence ensures that the average circulating current is zero,which provides a superior and feasible solution to satisfy the demands of high-power operations.However,a large instantaneous loop current exists between shunt converters,which leads to disadvantages such as higher switching device stress and loss.In this study,by utilizing the state-distribution redundancy provided by the integrated modulation process,a new design for switch-ing sequences is suggested for the integrated modulation of shunt three-level converters.This design aims to reduce the circulating current while better preserving the same output current harmonics than traditional parallel methods.The proposal includes an in-depth analysis and explanation of the implementation process.Finally,the proposed method is validated through simulations and prototype experi-ments.The results indicate that compared with traditional methods,the adoption of the improved switching sequence presented in this study leads to an average reduction of 3.2%in the total harmonic distortion of the inverter’s output and an average decrease of 32%in the amplitude of the circulating current.Both the output harmonics and circulating currents are significantly suppressed across various modulation indices. 展开更多
关键词 Circulating current Neutral point clamped Parallel operating inverters Space vector modulation
在线阅读 下载PDF
Coordinated control between a grid forming inverter and grid following inverters suppling power in a standalone microgrid 被引量:1
13
作者 Junichi Arai Yasuhiro Taguchi 《Global Energy Interconnection》 EI CAS CSCD 2022年第3期259-265,共7页
Battery energy storage systems,fuel cells,and photovoltaic generators are being adopted in distribution networks to achieve CO;emission reduction.These power sources require inverters to connect to AC networks.However... Battery energy storage systems,fuel cells,and photovoltaic generators are being adopted in distribution networks to achieve CO;emission reduction.These power sources require inverters to connect to AC networks.However,sub-networks,such as a microgrids containing inverter power sources,may be disconnected from the utility network and operated in a standalone mode during extended blackouts.This study focuses on a standalone microgrid supplied by inverter power sources without a synchronous generator and proposes a new microgrid inverter control.In this inverter control,a single grid forming inverter is operated as a master power source to determine frequency and voltage,and other inverters,called grid following inverters,are operated as subordinate power sources with active and reactive power control.The necessary functions in the energy management system are examined,and the coordinated operation of all inverters in the microgrid is demonstrated via simulation. 展开更多
关键词 inverter control MICROGRID Standalone operation Energy management system Grid forming inverter Grid following inverter
在线阅读 下载PDF
RELIABLE HYSTERESIS CURRENT CONTROLLED DUAL BUCK HALF BRIDGE INVERTER 被引量:6
14
作者 刘军 严仰光 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2003年第1期67-72,共6页
A highly efficient and re liable topology-dual buck half bridge inverter (DBI) is introduced. The existenc e of discontinuous conduction mode (DCM) operation state requires the bias of in du ctor current for DBI imple... A highly efficient and re liable topology-dual buck half bridge inverter (DBI) is introduced. The existenc e of discontinuous conduction mode (DCM) operation state requires the bias of in du ctor current for DBI implemented with linear controllers like ramp comparison SP WM (RCSPWM) controllers. A novel operation scheme for DBI and a hysteresis curre nt controlled dual buck half bridge inverter (HCDBI) are proposed. The bias curr ent required by RCSPWM DBI is eliminated and conduction losses are dramatically reduced. HCDBI has greatly improved the modulation performance in DCM region for the benefit of its excellent command tracking capability. The operational schem e and control strategy are presented. Power losses of the conventional half brid ge inverter (CHBI) and HCDBI are compared with mathematical computation, and exp erimental verification is also executed. Both calculational and experimental res ults verify that HCDBI has a superior switching performance over CHBI. Its exce llent high frequency operational capacity provides another access to realize high fre quency operation of inverters. 展开更多
关键词 high frequency switch ing inverterS hysteresis current control half bridge
在线阅读 下载PDF
Minimization of Switching Devices and Driver Circuits in Multilevel Inverter
15
作者 S. Jawahar P. Ramamoorthy 《Circuits and Systems》 2016年第10期3371-3383,共13页
The various configurations of multilevel inverter involve the use of more numbers of switching devices, energy storage devices and/or unidirectional devices. Each switching unit necessitates the add-on driver circuit ... The various configurations of multilevel inverter involve the use of more numbers of switching devices, energy storage devices and/or unidirectional devices. Each switching unit necessitates the add-on driver circuit for proper functionality. Cascaded H-Bridge Multilevel Inverter requires overlapped switching pulses for the switching devices in positive and negative arms of the bridge which may lead to short circuit during the device failure. This work addresses the problems in different configurations of multilevel inverter by using reduced number of switching and energy storage devices and driver circuits. In the present approach Single Switch is used for each stair case positive output and single H-Bridge for phase reversal. Driver circuits are reduced by using the property of body diode of the MOSFET. Switching pulses are generated by Arduino Development Board. The circuit is simulated using Matlab. More so, through experimental means, it is physically tested and results are analyzed for the 5-step inverter and thereby simulation is fully validated. Consequently, cycloconverter operation of the circuit is simulated using Matlab. Moreover, half bridge configuration of the multilevel inverter is also analyzed for high frequency induction heating applications. 展开更多
关键词 H-Bridge Multilevel inverter Single Switch Multilevel inverter Body Diode Switching Angle THD CYCLOCONVERTER Half Bridge Multilevel inverter
在线阅读 下载PDF
Capacitor Pattern H-Bridge Multilevel Inverter (CPHMLI) Using Phase Diposition Pulse Width Modulation for Grid Applications
16
作者 M. S. Saravanan R. Jeyabharath 《Circuits and Systems》 2016年第10期3310-3319,共10页
This work presents an implementation of an innovative single phase multilevel inverter using capacitors with reduced switches. The proposed Capacitor pattern H-bridge Multilevel Inverter (CPHMLI) topology consists of ... This work presents an implementation of an innovative single phase multilevel inverter using capacitors with reduced switches. The proposed Capacitor pattern H-bridge Multilevel Inverter (CPHMLI) topology consists of a proper number of Capacitor connected with switches and power sources. The advanced switching control supplied by Pulse Width Modulation (PDPWM) to attain mixed staircase switching state. The charging and discharging mode are achieved by calculating the voltage error at the load. Furthermore, to accomplish the higher voltage levels at the output with less number of semiconductors switches and simple commutation designed using CPHMLI topology. To prove the performance and effectiveness of the proposed approach, a set of experiments performed under various load conditions using MATLAB tool. 展开更多
关键词 Switched Capacitor Multilevel inverter Phase Diposition Pulse Width Modulation Capacitor Pattern Based Multilevel inverter Total Harmonic Distortion Cascaded H-Bridge 17-Level inverter
在线阅读 下载PDF
Research on a Novel Inverter Based on DC/DC Converter Topology 被引量:1
17
作者 谢少军 樊英 周大可 《Journal of Southeast University(English Edition)》 EI CAS 2002年第4期341-345,共5页
The conventional inverters have the shortcomings of straightway conduction in transistors and the difficulty of realizing soft swit ̄ching. A novel inverter based on the DC/DC converter topology is presented. The inve... The conventional inverters have the shortcomings of straightway conduction in transistors and the difficulty of realizing soft swit ̄ching. A novel inverter based on the DC/DC converter topology is presented. The inverter is comprised of a combined Buck/Boost DC/DC converter and a bridge circuit. The front stage converter is controlled to output variable DC voltage and the bridge circuit is used to convert the DC voltage to AC output. The energy feedback technology and one circle control scheme are used t... 展开更多
关键词 inverter DC/DC converter PWM one circle control soft switching
在线阅读 下载PDF
Applications of cascade multilevel inverters 被引量:3
18
作者 彭方正 钱照明 《Journal of Zhejiang University Science》 EI CSCD 2003年第6期658-665,共8页
Cascade multilevel inverters have been developed for electric utility applications. A cascade M level inverter consists of (M 1)/2 H bridges in which each bridge's dc voltage is supported by its own dc capacito... Cascade multilevel inverters have been developed for electric utility applications. A cascade M level inverter consists of (M 1)/2 H bridges in which each bridge's dc voltage is supported by its own dc capacitor. The new inverter can: (1) generate almost sinusoidal waveform voltage while only switching one time per fundamental cycle; (2) dispense with multi pulse inverters' transformers used in conventional utility interfaces and static var compensators; (3) enables direct parallel or series transformer less connection to medium and high voltage power systems. In short, the cascade inverter is much more efficient and suitable for utility applications than traditional multi pulse and pulse width modulation (PWM) inverters. The authors have experimentally demonstrated the superiority of the new inverter for power supply, (hybrid) electric vehicle (EV) motor drive, reactive power (var) and harmonic compensation. This paper summarizes the features, feasibility, and control schemes of the cascade inverter for utility applications including utility interface of renewable energy, voltage regulation, var compensation, and harmonic filtering in power systems. Analytical, simulated, and experimental results demonstrated the superiority of the new inverters. 展开更多
关键词 Cascade inverter Multilevel inverter Utility application Power supply
在线阅读 下载PDF
THREE-PHASE BRIDGE INVERTER FOR 9kW DOUBLY SALIENT PERMANENT MAGNET MOTOR
19
作者 黄伟君 秦海鸿 +1 位作者 王慧贞 严仰光 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2006年第1期27-33,共7页
The three-phase bridge inverter is used as the converter topology in the power controller for a 9 kW doubly salient permanent magnet (DSPM) motor. Compared with common three-phase bridge inverters, the proposed inve... The three-phase bridge inverter is used as the converter topology in the power controller for a 9 kW doubly salient permanent magnet (DSPM) motor. Compared with common three-phase bridge inverters, the proposed inverter works under more complicated conditions with different principles for special winding back EMFs, position signals of hall sensors, and the given mode of switches. The ideal steady driving principles of the inverter for the motor are given. The working state with asymmetric winding back EMFs, inaccurate position signals of hall sensors, and the changing input voltage is analyzed. Finally, experimental results vertify that the given anal ysis is correct. 展开更多
关键词 doubly salient permanent magnet motor three-phase bridge inverter winding back EMF position signal of hall sensor input voltage
在线阅读 下载PDF
DC LOOP-CURRENT DETECTING AND RESTRAINING METHODS FOR PARALLEL INVERTER SYSTEM
20
作者 陈良亮 肖岚 严仰光 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2004年第1期1-6,共6页
DC component is contained in inverter output voltage due to many reasons such as the zero-point deviation of operational amplifiers and the differences between power switching transistors′ characteristics. For the pa... DC component is contained in inverter output voltage due to many reasons such as the zero-point deviation of operational amplifiers and the differences between power switching transistors′ characteristics. For the parallel inverter system without output isolation transformers, the difference of DC components of the output voltage can cause large DC loop-current among modular inverters. Aiming at this problem, this paper studies several DC loop-current detecting and restraining methods. By digital adjustment with high precision on the DC components of reference sine wave, the DC components of inverter′s output voltage can be adjusted to restrain DC loop-current. Experimental results prove that the DC loop-current detecting and restraining methods have a good performance. 展开更多
关键词 DC loop-current DETECT digital adjustment parallel inverter
在线阅读 下载PDF