Although inductively coupled plasma mass spectrometry(ICP-MS) retains high sensitivity and has been intensively used for the measurement of ^(99)Tc, it usually suffers from tedious, expensive, and timeconsuming sample...Although inductively coupled plasma mass spectrometry(ICP-MS) retains high sensitivity and has been intensively used for the measurement of ^(99)Tc, it usually suffers from tedious, expensive, and timeconsuming sample pretreatments due to the isobaric interferences from ^(99)Ru and ^(98)Mo^(1)H. Herein, capillary electrophoresis(CE) was applied as sample introduction system for the sensitive, and interferencefree determination of ^(99)TcO_(4)^(-) from RuO_(4)^(-), and MoO_(4)^(2-) by ICP-MS with a simple sample treatment. Compared to the conventional methods, the hyphenated CE-ICP-MS avoids the use of expensive separation resins and reduces the consumption of mineral acid, representing a simpler, more efficient and environmentally benign approach. Moreover, the proposed method exhibits higher accuracy compared with the mathematical correction method using the natural isotope ratio of ^(99)Ru and ^(101)Ru, and significantly reduces sample consumption and the amount of waste, thus remarkably alleviating the radioactive exposure to operators and the pressure of radioactive waste treatment. Under the optimized conditions, the detection limits of 25 μg/L and 0.06 μg/L were obtained for RuO_(4)^(-) and ReO_(4)^(-)(Tc was replaced by Re), respectively, with relative standard deviation(RSD) lower than 5%. In addition, efficient recoveries of RuO_(4)^(-),ReO_(4)^(-),and ^(99)TcO_(4)^(-) from simulated Hanford site groundwater were achieved. The method is expected to be a promising candidate for sensitive and accurate analysis of ^(99)Tc from contaminated environmental samples.展开更多
基金the National Natural Science Foundation of China (Nos. U1867205, 21622508, and 21575092)Study on Physical/Chemical Characteristics Related to the Migration of Key Nuclides under Simulated Disposal Conditions (Phase Ⅱ) (Contract No. KGES 2019(170), dated February 21, 2019.) for financial support。
文摘Although inductively coupled plasma mass spectrometry(ICP-MS) retains high sensitivity and has been intensively used for the measurement of ^(99)Tc, it usually suffers from tedious, expensive, and timeconsuming sample pretreatments due to the isobaric interferences from ^(99)Ru and ^(98)Mo^(1)H. Herein, capillary electrophoresis(CE) was applied as sample introduction system for the sensitive, and interferencefree determination of ^(99)TcO_(4)^(-) from RuO_(4)^(-), and MoO_(4)^(2-) by ICP-MS with a simple sample treatment. Compared to the conventional methods, the hyphenated CE-ICP-MS avoids the use of expensive separation resins and reduces the consumption of mineral acid, representing a simpler, more efficient and environmentally benign approach. Moreover, the proposed method exhibits higher accuracy compared with the mathematical correction method using the natural isotope ratio of ^(99)Ru and ^(101)Ru, and significantly reduces sample consumption and the amount of waste, thus remarkably alleviating the radioactive exposure to operators and the pressure of radioactive waste treatment. Under the optimized conditions, the detection limits of 25 μg/L and 0.06 μg/L were obtained for RuO_(4)^(-) and ReO_(4)^(-)(Tc was replaced by Re), respectively, with relative standard deviation(RSD) lower than 5%. In addition, efficient recoveries of RuO_(4)^(-),ReO_(4)^(-),and ^(99)TcO_(4)^(-) from simulated Hanford site groundwater were achieved. The method is expected to be a promising candidate for sensitive and accurate analysis of ^(99)Tc from contaminated environmental samples.