This work proposes an alternative strategy to the use of a speed sensor in <span style="white-space:normal;font-size:10pt;font-family:;" "="">the implementation of active and reactive po...This work proposes an alternative strategy to the use of a speed sensor in <span style="white-space:normal;font-size:10pt;font-family:;" "="">the implementation of active and reactive power based model reference adaptive system (PQ-MRAS) estimator in order to calculate the rotor and stator resistances of an induction motor (IM) and the use of these parameters for the detection of inter-turn short circuits (ITSC) faults in the stator of this motor. The rotor and stator resistance estimation part of the IM is performed by the PQ-MRAS method in which the rotor angular velocity is reconstructed from the interconnected high gain observer (IHGO). The ITSC fault detection part is done by the derivation of stator resistance estimated by the PQ-</span><span style="white-space:normal;font-size:10pt;font-family:;" "="">MRAS estimator. In addition to the speed sensorless detection of ITSC faults of the IM, an approach to determine the number of shorted turns based on the difference between the phase current of the healthy and faulty machine is proposed. Simulation results obtained from the MATLAB/Simulink platform have shown that the PQ-MRAS estimator using an interconnected high-</span><span style="white-space:normal;font-size:10pt;font-family:;" "="">gain observer gives very similar results to those using the speed sensor. The </span><span style="white-space:normal;font-size:10pt;font-family:;" "="">estimation errors in the cases of speed variation and load torque are al</span><span style="white-space:normal;font-size:10pt;font-family:;" "="">mos</span><span style="white-space:normal;font-size:10pt;font-family:;" "="">t identical. Variations in stator and rotor resistances influence the per</span><span style="white-space:normal;font-size:10pt;font-family:;" "="">formance of the observer and lead to poor estimation of the rotor resistance. The results of ITSC fault detection using IHGO are very similar to the results in the literature using the same diagnostic approach with a speed sensor.</span>展开更多
This article proposes a multi-tiered fault detection system for series-connected lithium-ion battery modules.Improper use of batteries can lead to electrolyte decomposition,resulting in the formation of lithium dendri...This article proposes a multi-tiered fault detection system for series-connected lithium-ion battery modules.Improper use of batteries can lead to electrolyte decomposition,resulting in the formation of lithium dendrites.These dendrites may pierce the separator,leading to the failure of the insulation layer between electrodes and causing micro short circuits.When a micro short circuit occurs,the electrolyte typically undergoes exothermic reactions,leading to thermal runaway and posing a safety risk to users.Relying solely on temperature-based judgment mechanisms within the battery management system often results in delayed intervention.To address this issue,the article develops a multi-tiered fault detection algorithm for series-connected lithium-ion batteries.This algorithm can effectively diagnose micro short circuits,aging,and normal batteries using minimal battery data,thereby improving diagnostic accuracy and enhancing the flexibility of fault detection.Simulations and experiments conducted under various levels of micro short circuits validate the effectiveness of the algorithm,demonstrating its ability to distinguish between short-circuited,aged,and normal batteries under different conditions.This technology can be applied to electric vehicles and energy storage systems,enabling early warnings to ensure safety and prevent thermal runaway.展开更多
Synchronous generators are important components of power systems and are necessary to maintain its normal and stable operation.To perform the fault diagnosis of mild inter-turn short circuit in the excitation winding ...Synchronous generators are important components of power systems and are necessary to maintain its normal and stable operation.To perform the fault diagnosis of mild inter-turn short circuit in the excitation winding of a synchronous generator,a gate recurrent unit-convolutional neural network(GRU-CNN)model whose structural parameters were determined by improved particle swarm optimization(IPSO)is proposed.The outputs of the model are the excitation current and reactive power.The total offset distance,which is the fusion of the offset distance of the excitation current and offset distance of the reactive power,was selected as the fault judgment criterion.The fusion weights of the excitation current and reactive power were determined using the anti-entropy weighting method.The fault-warning threshold and fault-warning ratio were set according to the normal total offset distance,and the fault warning time was set according to the actual situation.The fault-warning time and fault-warning ratio were used to avoid misdiagnosis.The proposed method was verified experimentally.展开更多
This paper proposed a new diagnosis model for the stator inter-turn short circuit fault in synchronous generators.Different from the past methods focused on the current or voltage signals to diagnose the electrical fa...This paper proposed a new diagnosis model for the stator inter-turn short circuit fault in synchronous generators.Different from the past methods focused on the current or voltage signals to diagnose the electrical fault,the sta-tor vibration signal analysis based on ACMD(adaptive chirp mode decomposition)and DEO3S(demodulation energy operator of symmetrical differencing)was adopted to extract the fault feature.Firstly,FT(Fourier trans-form)is applied to the vibration signal to obtain the instantaneous frequency,and PE(permutation entropy)is calculated to select the proper weighting coefficients.Then,the signal is decomposed by ACMD,with the instan-taneous frequency and weighting coefficient acquired in the former step to obtain the optimal mode.Finally,DEO3S is operated to get the envelope spectrum which is able to strengthen the characteristic frequencies of the stator inter-turn short circuit fault.The study on the simulating signal and the real experiment data indicates the effectiveness of the proposed method for the stator inter-turn short circuit fault in synchronous generators.In addition,the comparison with other methods shows the superiority of the proposed model.展开更多
The relentless down-scaling of electronics grands the modern integrated circuits(ICs)with the high speed,low power dissipation and low cost,fulfilling diverse demands of modern life.Whereas,with the semiconductor indu...The relentless down-scaling of electronics grands the modern integrated circuits(ICs)with the high speed,low power dissipation and low cost,fulfilling diverse demands of modern life.Whereas,with the semiconductor industry entering into sub-10 nm technology nodes,degrading device performance and increasing power consumption give rise to insurmountable roadblocks confronted by modern ICs that need to be conquered to sustain the Moore law's life.Bulk semiconductors like prevalent Si are plagued by seriously degraded carrier mobility as thickness thinning down to sub-5 nm,which is imperative to maintain sufficient gate electrostatic controllability to combat the increasingly degraded short channel effects.Nowadays,the emergence of two-dimensional(2D)materials opens up new gateway to eschew the hurdles laid in front of the scaling trend of modern IC,mainly ascribed to their ultimately atomic thickness,capability to maintain carrier mobility with thickness thinning down,dangling-bonds free surface,wide bandgaps tunability and feasibility to constitute diverse heterostructures.Blossoming breakthroughs in discrete electronic device,such as contact engineering,dielectric integration and vigorous channel-length scaling,or large circuits arrays,as boosted yields,improved variations and full-functioned processor fabrication,based on 2D materials have been achieved nowadays,facilitating 2D materials to step under the spotlight of IC industry to be treated as the most potential future successor or complementary counterpart of incumbent Si to further sustain the down-scaling of modern IC.展开更多
An 'Integrated Device and Circuit simulator' for thin film (0.05-0.2μm) submicron (0.5μm) and deep submicron (0.15, 0.25,0.35μm) CMOS/ SOI integrated circuit has been developed. This simulator has been used...An 'Integrated Device and Circuit simulator' for thin film (0.05-0.2μm) submicron (0.5μm) and deep submicron (0.15, 0.25,0.35μm) CMOS/ SOI integrated circuit has been developed. This simulator has been used for design and fabrication and physical library development of thin film submicron and deep submicron CMOS/ SOI integrated circuit.展开更多
We review the short-circuit testing of distribution and power transformers, and include a list of 110-220kV power transformers tested up to February 2002.
External short circuit(ESC)of lithium-ion batteries is one of the common and severe electrical failures in electric vehicles.In this study,a novel thermal modelis developed to capture the temperature behavior of batte...External short circuit(ESC)of lithium-ion batteries is one of the common and severe electrical failures in electric vehicles.In this study,a novel thermal modelis developed to capture the temperature behavior of batteries under ESC conditions.Experiments were systematically performed under different battery initial state of charge and ambient temperatures.Based on the experimental results,we employed an extreme learming machine(ELM)-based thermal(ELMT)model to depict battery temperature behavior under ESC,where a lumped-state thermal model was used to replace the activation function of conventional ELMs.To demonstrate the effectiveness of the proposed model,wecompared the ELMT model with a multi-lumped-state thermal(MLT)model parameterized by thegenetic algorithm using the experimental data from various sets of battery cells.It is shown that the ELMT model can achieve higher computa-tional efficiency than the MLT model and better fitting and prediction accuracy,where the average root mean squared error(RMSE)of the fitting is 0.65℃ for the ELMT model and 3.95℃ for the MLT model,and the RMES of the prediction under new data set is 3.97℃ for the ELMT model and 6.11℃ for the MLT model.展开更多
Internal short circuit(ISC)is the major failure problem for the safe application of lithium-ion batteries,especially for the batteries with high energy density.However,how to quantify the hazard aroused by the ISC,and...Internal short circuit(ISC)is the major failure problem for the safe application of lithium-ion batteries,especially for the batteries with high energy density.However,how to quantify the hazard aroused by the ISC,and what kinds of ISC will lead to thermal runaway are still unclear.This paper investigates the thermal-electrical coupled behaviors of ISC,using batteries with Li(Ni_(1/3)CO_(1/3)Mn_(1/3))O_(2) cathode and composite separator.The electrochemical impedance spectroscopy of customized battery that has no LiPF6 salt is utilized to standardize the resistance of ISC.Furthermore,this paper compares the thermal-electrical coupled behaviors of the above four types of ISC at different states-of-charge.There is an area expansion phenomenon for the aluminum-anode type of ISC.The expansion effect of the failure area directly links to the melting and collapse of separator,and plays an important role in further evolution of thermal runaway.This work provides guidance to the development of the ISC models,detection algorithms,and correlated countermeasures.展开更多
Aim at improving the stability of the Short-circuiting Gas Metal Arc Welding (GMAW-S) process for the enhanced speed usage, effects of current waveform parameters during short-term on the welding stability have been...Aim at improving the stability of the Short-circuiting Gas Metal Arc Welding (GMAW-S) process for the enhanced speed usage, effects of current waveform parameters during short-term on the welding stability have been investigated by experimental method. The welding power source used for the research is an inverter with a special current waveform control. It is shown that the spatter decreases at first then increases with each increase of the low current period, current increase rate and the maximum current limit. The test results are provided for welding of 1 mm and 3 mm mild steel at speed of 1.2 m/min. The stable GMA W-S process under high speed welding condition has been achieved by optimizing the parameters.展开更多
A general industrial CCD( ICCD) camera is redesigned to detect the weld pool without arc at the period of short circuiting, so that the interference of arc and spatter during CO2 short circuiting arc welding is elim...A general industrial CCD( ICCD) camera is redesigned to detect the weld pool without arc at the period of short circuiting, so that the interference of arc and spatter during CO2 short circuiting arc welding is eliminated. Through the analysis of weld pool image, both size parameters (such as weld pool area A, weld pool length L1, L2 and weld pool breadth b) and contour parameters (b, which describe the curves of weld pool boundany) ,which could indicate the shape features of weld pool, had been defined to express weld pool information quantitatively. The investigation of the relationships between weld pool shape parameters and welding process parameters may be beneficial to the quality control of CO2 welding.展开更多
Based on the chaos theory, an idea is put forward to analyze the short circuit Gas Metal Arc Welding ( GMAW-S) process. The theory of phase space reconstruction and related algorithms such as mutual information and ...Based on the chaos theory, an idea is put forward to analyze the short circuit Gas Metal Arc Welding ( GMAW-S) process. The theory of phase space reconstruction and related algorithms such as mutual information and so on, are applied to analyze the chaos of the GMAW-S process. The largest Lyapunov exponents of some current time series are calculated, and the results indicate that chaos exists in the GMAW-S process. The research of the chaos in the GMAW-S process can be help to get new knowledge of the process.展开更多
Developing precise and fast methods for short circuit detection is crucial for preventing or mitigating the risk of safety issues of lithium-ion batteries(LIBs).In this paper,we developed a Convolutional Neural Networ...Developing precise and fast methods for short circuit detection is crucial for preventing or mitigating the risk of safety issues of lithium-ion batteries(LIBs).In this paper,we developed a Convolutional Neural Networks(CNN)based model that can quickly and precisely predict the short circuit resistance of LIB cells during various working conditions.Cycling tests of cells with an external short circuit(ESC)are produced to obtain the database and generate the training/testing samples.The samples are sequences of voltage,current,charging capacity,charging energy,total charging capacity,total charging energy with a length of 120 s and frequency of 1 Hz,and their corresponding short circuit resistances.A big database with~6×10^(5)samples are generated,covering various short circuit resistances(47~470Ω),current loading modes(Constant current-constant voltage(CC-CV)and drive cycle),and electrochemical states(cycle numbers from 1 to 300).Results show that the average relative absolute error of five random sample splits is 6.75%±2.8%.Further parametric analysis indicates the accuracy estimation benefits from the appropriate model setups:the optimized input sequence length(~120 s),feature selection(at least one total capacity-related variable),and rational model design,using multiple layers with different kernel sizes.This work highlights the capabilities of machine learning algorithms and data-driven methodologies in real-time safety risk prediction for batteries.展开更多
Based on simple analytical equations, short circuit current density (Jsc) of the organic bulk heterojunction solar cells has been calculated. It is found that the optical interference effect plays a very important r...Based on simple analytical equations, short circuit current density (Jsc) of the organic bulk heterojunction solar cells has been calculated. It is found that the optical interference effect plays a very important role in the determination of Jsc; and obvious oscillatory behaviour of Jsc was observed as a function of thickness. At the same time, the influence of the carrier lifetime on Jsc also cannot be neglected. When the carrier lifetime is relatively short, Jsc only increases at the initial stage and then decreases rapidly with the increase of active layer thickness. However, for a relatively long carrier lifetime, the exciton dissociation probability must be considered, and Jsc behaves wave-like with the increase of active layer thickness. The validity of this model is confirmed by the experimental results.展开更多
A new kind of simple and flexible CO2 welding system was developed to carry out waveform control. The system consisted of IGBT inverter, PWM circuit and microprocessor unit ( MPU) , in which the output current of co...A new kind of simple and flexible CO2 welding system was developed to carry out waveform control. The system consisted of IGBT inverter, PWM circuit and microprocessor unit ( MPU) , in which the output current of constant current (CC) power supply could be changed according to transient physical state, and the variable down slope rate control could be used to ensure a stable welding process. The welding experiment results proved the effectiveness of this control approach.展开更多
Short circuit transfer involves bridging between the consumable electrode and the weld pool, associated with variations of electrical parameters which characterize the change of molten metal bridge state and are very ...Short circuit transfer involves bridging between the consumable electrode and the weld pool, associated with variations of electrical parameters which characterize the change of molten metal bridge state and are very important for the control of .spatter. In this paper, electrical process parameters and short circuit transfer images were simultaneously recorded with a LabView-based synchronous sensing and visualizing system. The arc^bridge resistance and derivatives of welding current, arc voltage and arc resistance at various instants were calculated by means of offline analysis of the welding current, arc voltage and droplet images. Parameters and their feature values indicating the onset of short circuit and the oncoming necking-down of molten metal bridge were determined. Using the calculated feature values, bridge-state-feedback control for .short circuit transfer was realized with a spatter rate less than 0. 25%.展开更多
To reduce the pressure on contacts and circuit breaker and realize the zone selective interlocking (ZSI) function above the instantaneous protection threshold (e.g., >10In), the short circuit current needs to be ea...To reduce the pressure on contacts and circuit breaker and realize the zone selective interlocking (ZSI) function above the instantaneous protection threshold (e.g., >10In), the short circuit current needs to be early detected. The state-of–art of early short circuit detection (ESCD) method is reviewed. Based on the equivalent model of the short circuit, a new method based on the current and its integration is proposed. The prospective current value can be detected in the early stage of the short circuit. According to the evaluation result, the short circuit current can be early forecasted with the proposed method.展开更多
Based on the phase space reconstruction of welding current in short-circuiting transfer arc welding under carbon dioxide, the approximate entropy of welding current and its standard deviation have been calculated and ...Based on the phase space reconstruction of welding current in short-circuiting transfer arc welding under carbon dioxide, the approximate entropy of welding current and its standard deviation have been calculated and analyzed at different welding speeds and different electrode extensions respectively. The experimental and calculated results show that at a certain arc voltage, wire feeding rate and gas flow rate, welding speed and electrode extension have significant effects not only on the approximate entropy of welding current, but also on the stability of welding process. Further analysis proves that when the welding speed and electrode extension are in an appropriate range respectively, the welding current approximate entropy attains maximum and its standard deviation minimum. Just under such circumstances, the welding process is in the most stable state.展开更多
By means of high-speed photograph and synchronous oscillograph, the appearance and technical features of non-explosive short circuiting transfer using basic electrodes are investigated, and the conditions to form this...By means of high-speed photograph and synchronous oscillograph, the appearance and technical features of non-explosive short circuiting transfer using basic electrodes are investigated, and the conditions to form this metal transfer mode are discussed. It is shown that the metal transfer mode has its high frequency of droplet, short period of arc extinguishing and long arc igniting period. This metal transfer mode is expected for basic electrodes for its less spatter and higher deposition efficiency.展开更多
In order to detecting and tracking along the weld seam with rotating arc sensor in underwater welding,the highpressure water environment rotating arc welding hardware platform is established and welding experiments us...In order to detecting and tracking along the weld seam with rotating arc sensor in underwater welding,the highpressure water environment rotating arc welding hardware platform is established and welding experiments using rotating arc sensor is done. Different radius of rotating arc sensor is used. And the corresponding welding current and voltage is obtained,which is compared with the results of rotating arc sensor short-circuit process simulation model under high-pressure water environment established in this article. The results show that under high-pressure water environment,rotating arc radius should be optimized,otherwise the short-circuit-arcing cycle will transit to a short-circuit-arcing-abruption cycle,making the welding quality poor. At last the critical radius between the short-circuit-arcing cycle and short-circuit-arcing-abruption cycle under high-pressure water environment is obtained.展开更多
文摘This work proposes an alternative strategy to the use of a speed sensor in <span style="white-space:normal;font-size:10pt;font-family:;" "="">the implementation of active and reactive power based model reference adaptive system (PQ-MRAS) estimator in order to calculate the rotor and stator resistances of an induction motor (IM) and the use of these parameters for the detection of inter-turn short circuits (ITSC) faults in the stator of this motor. The rotor and stator resistance estimation part of the IM is performed by the PQ-MRAS method in which the rotor angular velocity is reconstructed from the interconnected high gain observer (IHGO). The ITSC fault detection part is done by the derivation of stator resistance estimated by the PQ-</span><span style="white-space:normal;font-size:10pt;font-family:;" "="">MRAS estimator. In addition to the speed sensorless detection of ITSC faults of the IM, an approach to determine the number of shorted turns based on the difference between the phase current of the healthy and faulty machine is proposed. Simulation results obtained from the MATLAB/Simulink platform have shown that the PQ-MRAS estimator using an interconnected high-</span><span style="white-space:normal;font-size:10pt;font-family:;" "="">gain observer gives very similar results to those using the speed sensor. The </span><span style="white-space:normal;font-size:10pt;font-family:;" "="">estimation errors in the cases of speed variation and load torque are al</span><span style="white-space:normal;font-size:10pt;font-family:;" "="">mos</span><span style="white-space:normal;font-size:10pt;font-family:;" "="">t identical. Variations in stator and rotor resistances influence the per</span><span style="white-space:normal;font-size:10pt;font-family:;" "="">formance of the observer and lead to poor estimation of the rotor resistance. The results of ITSC fault detection using IHGO are very similar to the results in the literature using the same diagnostic approach with a speed sensor.</span>
文摘This article proposes a multi-tiered fault detection system for series-connected lithium-ion battery modules.Improper use of batteries can lead to electrolyte decomposition,resulting in the formation of lithium dendrites.These dendrites may pierce the separator,leading to the failure of the insulation layer between electrodes and causing micro short circuits.When a micro short circuit occurs,the electrolyte typically undergoes exothermic reactions,leading to thermal runaway and posing a safety risk to users.Relying solely on temperature-based judgment mechanisms within the battery management system often results in delayed intervention.To address this issue,the article develops a multi-tiered fault detection algorithm for series-connected lithium-ion batteries.This algorithm can effectively diagnose micro short circuits,aging,and normal batteries using minimal battery data,thereby improving diagnostic accuracy and enhancing the flexibility of fault detection.Simulations and experiments conducted under various levels of micro short circuits validate the effectiveness of the algorithm,demonstrating its ability to distinguish between short-circuited,aged,and normal batteries under different conditions.This technology can be applied to electric vehicles and energy storage systems,enabling early warnings to ensure safety and prevent thermal runaway.
文摘Synchronous generators are important components of power systems and are necessary to maintain its normal and stable operation.To perform the fault diagnosis of mild inter-turn short circuit in the excitation winding of a synchronous generator,a gate recurrent unit-convolutional neural network(GRU-CNN)model whose structural parameters were determined by improved particle swarm optimization(IPSO)is proposed.The outputs of the model are the excitation current and reactive power.The total offset distance,which is the fusion of the offset distance of the excitation current and offset distance of the reactive power,was selected as the fault judgment criterion.The fusion weights of the excitation current and reactive power were determined using the anti-entropy weighting method.The fault-warning threshold and fault-warning ratio were set according to the normal total offset distance,and the fault warning time was set according to the actual situation.The fault-warning time and fault-warning ratio were used to avoid misdiagnosis.The proposed method was verified experimentally.
基金supported in part by the National Natural Science Foundation of China(52177042)Natural Science Foundation of Hebei Province(E2020502031)+1 种基金the Fundamental Research Funds for the Central Universities(2017MS151),Suzhou Social Developing Innovation Project of Science and Technology(SS202134)the Top Youth Talent Support Program of Hebei Province([2018]-27).
文摘This paper proposed a new diagnosis model for the stator inter-turn short circuit fault in synchronous generators.Different from the past methods focused on the current or voltage signals to diagnose the electrical fault,the sta-tor vibration signal analysis based on ACMD(adaptive chirp mode decomposition)and DEO3S(demodulation energy operator of symmetrical differencing)was adopted to extract the fault feature.Firstly,FT(Fourier trans-form)is applied to the vibration signal to obtain the instantaneous frequency,and PE(permutation entropy)is calculated to select the proper weighting coefficients.Then,the signal is decomposed by ACMD,with the instan-taneous frequency and weighting coefficient acquired in the former step to obtain the optimal mode.Finally,DEO3S is operated to get the envelope spectrum which is able to strengthen the characteristic frequencies of the stator inter-turn short circuit fault.The study on the simulating signal and the real experiment data indicates the effectiveness of the proposed method for the stator inter-turn short circuit fault in synchronous generators.In addition,the comparison with other methods shows the superiority of the proposed model.
基金supported by start-up capital of Ningbo Eastern Institute of technology。
文摘The relentless down-scaling of electronics grands the modern integrated circuits(ICs)with the high speed,low power dissipation and low cost,fulfilling diverse demands of modern life.Whereas,with the semiconductor industry entering into sub-10 nm technology nodes,degrading device performance and increasing power consumption give rise to insurmountable roadblocks confronted by modern ICs that need to be conquered to sustain the Moore law's life.Bulk semiconductors like prevalent Si are plagued by seriously degraded carrier mobility as thickness thinning down to sub-5 nm,which is imperative to maintain sufficient gate electrostatic controllability to combat the increasingly degraded short channel effects.Nowadays,the emergence of two-dimensional(2D)materials opens up new gateway to eschew the hurdles laid in front of the scaling trend of modern IC,mainly ascribed to their ultimately atomic thickness,capability to maintain carrier mobility with thickness thinning down,dangling-bonds free surface,wide bandgaps tunability and feasibility to constitute diverse heterostructures.Blossoming breakthroughs in discrete electronic device,such as contact engineering,dielectric integration and vigorous channel-length scaling,or large circuits arrays,as boosted yields,improved variations and full-functioned processor fabrication,based on 2D materials have been achieved nowadays,facilitating 2D materials to step under the spotlight of IC industry to be treated as the most potential future successor or complementary counterpart of incumbent Si to further sustain the down-scaling of modern IC.
文摘An 'Integrated Device and Circuit simulator' for thin film (0.05-0.2μm) submicron (0.5μm) and deep submicron (0.15, 0.25,0.35μm) CMOS/ SOI integrated circuit has been developed. This simulator has been used for design and fabrication and physical library development of thin film submicron and deep submicron CMOS/ SOI integrated circuit.
文摘We review the short-circuit testing of distribution and power transformers, and include a list of 110-220kV power transformers tested up to February 2002.
基金support by the National Key Researchand Development Program of China(2018YFBO104100).
文摘External short circuit(ESC)of lithium-ion batteries is one of the common and severe electrical failures in electric vehicles.In this study,a novel thermal modelis developed to capture the temperature behavior of batteries under ESC conditions.Experiments were systematically performed under different battery initial state of charge and ambient temperatures.Based on the experimental results,we employed an extreme learming machine(ELM)-based thermal(ELMT)model to depict battery temperature behavior under ESC,where a lumped-state thermal model was used to replace the activation function of conventional ELMs.To demonstrate the effectiveness of the proposed model,wecompared the ELMT model with a multi-lumped-state thermal(MLT)model parameterized by thegenetic algorithm using the experimental data from various sets of battery cells.It is shown that the ELMT model can achieve higher computa-tional efficiency than the MLT model and better fitting and prediction accuracy,where the average root mean squared error(RMSE)of the fitting is 0.65℃ for the ELMT model and 3.95℃ for the MLT model,and the RMES of the prediction under new data set is 3.97℃ for the ELMT model and 6.11℃ for the MLT model.
基金supported by the Ministry of Science and Technology of China under the contract No.2019YFE0100200the National Natural Science Foundation of China(grant Nos.51706117,52076121)funded by the Tsinghua Scholarship for Overseas Graduate Studies。
文摘Internal short circuit(ISC)is the major failure problem for the safe application of lithium-ion batteries,especially for the batteries with high energy density.However,how to quantify the hazard aroused by the ISC,and what kinds of ISC will lead to thermal runaway are still unclear.This paper investigates the thermal-electrical coupled behaviors of ISC,using batteries with Li(Ni_(1/3)CO_(1/3)Mn_(1/3))O_(2) cathode and composite separator.The electrochemical impedance spectroscopy of customized battery that has no LiPF6 salt is utilized to standardize the resistance of ISC.Furthermore,this paper compares the thermal-electrical coupled behaviors of the above four types of ISC at different states-of-charge.There is an area expansion phenomenon for the aluminum-anode type of ISC.The expansion effect of the failure area directly links to the melting and collapse of separator,and plays an important role in further evolution of thermal runaway.This work provides guidance to the development of the ISC models,detection algorithms,and correlated countermeasures.
文摘Aim at improving the stability of the Short-circuiting Gas Metal Arc Welding (GMAW-S) process for the enhanced speed usage, effects of current waveform parameters during short-term on the welding stability have been investigated by experimental method. The welding power source used for the research is an inverter with a special current waveform control. It is shown that the spatter decreases at first then increases with each increase of the low current period, current increase rate and the maximum current limit. The test results are provided for welding of 1 mm and 3 mm mild steel at speed of 1.2 m/min. The stable GMA W-S process under high speed welding condition has been achieved by optimizing the parameters.
基金This project is supported by National 863 project( No.412-9913-02)and National Natural Science Foundation of China(No.599750
文摘A general industrial CCD( ICCD) camera is redesigned to detect the weld pool without arc at the period of short circuiting, so that the interference of arc and spatter during CO2 short circuiting arc welding is eliminated. Through the analysis of weld pool image, both size parameters (such as weld pool area A, weld pool length L1, L2 and weld pool breadth b) and contour parameters (b, which describe the curves of weld pool boundany) ,which could indicate the shape features of weld pool, had been defined to express weld pool information quantitatively. The investigation of the relationships between weld pool shape parameters and welding process parameters may be beneficial to the quality control of CO2 welding.
基金The work was supported by National Natural Science Foundation of China (No 50375053,50575077)
文摘Based on the chaos theory, an idea is put forward to analyze the short circuit Gas Metal Arc Welding ( GMAW-S) process. The theory of phase space reconstruction and related algorithms such as mutual information and so on, are applied to analyze the chaos of the GMAW-S process. The largest Lyapunov exponents of some current time series are calculated, and the results indicate that chaos exists in the GMAW-S process. The research of the chaos in the GMAW-S process can be help to get new knowledge of the process.
基金supported by the U.S.Department of Energy’s Office on Energy Efficiency and Renewable Energy(EERE)under the Advanced Manufacturing Office,award number DE-EE0009111。
文摘Developing precise and fast methods for short circuit detection is crucial for preventing or mitigating the risk of safety issues of lithium-ion batteries(LIBs).In this paper,we developed a Convolutional Neural Networks(CNN)based model that can quickly and precisely predict the short circuit resistance of LIB cells during various working conditions.Cycling tests of cells with an external short circuit(ESC)are produced to obtain the database and generate the training/testing samples.The samples are sequences of voltage,current,charging capacity,charging energy,total charging capacity,total charging energy with a length of 120 s and frequency of 1 Hz,and their corresponding short circuit resistances.A big database with~6×10^(5)samples are generated,covering various short circuit resistances(47~470Ω),current loading modes(Constant current-constant voltage(CC-CV)and drive cycle),and electrochemical states(cycle numbers from 1 to 300).Results show that the average relative absolute error of five random sample splits is 6.75%±2.8%.Further parametric analysis indicates the accuracy estimation benefits from the appropriate model setups:the optimized input sequence length(~120 s),feature selection(at least one total capacity-related variable),and rational model design,using multiple layers with different kernel sizes.This work highlights the capabilities of machine learning algorithms and data-driven methodologies in real-time safety risk prediction for batteries.
文摘Based on simple analytical equations, short circuit current density (Jsc) of the organic bulk heterojunction solar cells has been calculated. It is found that the optical interference effect plays a very important role in the determination of Jsc; and obvious oscillatory behaviour of Jsc was observed as a function of thickness. At the same time, the influence of the carrier lifetime on Jsc also cannot be neglected. When the carrier lifetime is relatively short, Jsc only increases at the initial stage and then decreases rapidly with the increase of active layer thickness. However, for a relatively long carrier lifetime, the exciton dissociation probability must be considered, and Jsc behaves wave-like with the increase of active layer thickness. The validity of this model is confirmed by the experimental results.
基金Supported by Research Project of Henan Science and Technology Foundation(0124110209,0211061900).
文摘A new kind of simple and flexible CO2 welding system was developed to carry out waveform control. The system consisted of IGBT inverter, PWM circuit and microprocessor unit ( MPU) , in which the output current of constant current (CC) power supply could be changed according to transient physical state, and the variable down slope rate control could be used to ensure a stable welding process. The welding experiment results proved the effectiveness of this control approach.
基金This work is supported by Shandong Natural Science Foundation ( Key Project) under contract No. ZR2010EZ005.
文摘Short circuit transfer involves bridging between the consumable electrode and the weld pool, associated with variations of electrical parameters which characterize the change of molten metal bridge state and are very important for the control of .spatter. In this paper, electrical process parameters and short circuit transfer images were simultaneously recorded with a LabView-based synchronous sensing and visualizing system. The arc^bridge resistance and derivatives of welding current, arc voltage and arc resistance at various instants were calculated by means of offline analysis of the welding current, arc voltage and droplet images. Parameters and their feature values indicating the onset of short circuit and the oncoming necking-down of molten metal bridge were determined. Using the calculated feature values, bridge-state-feedback control for .short circuit transfer was realized with a spatter rate less than 0. 25%.
文摘To reduce the pressure on contacts and circuit breaker and realize the zone selective interlocking (ZSI) function above the instantaneous protection threshold (e.g., >10In), the short circuit current needs to be early detected. The state-of–art of early short circuit detection (ESCD) method is reviewed. Based on the equivalent model of the short circuit, a new method based on the current and its integration is proposed. The prospective current value can be detected in the early stage of the short circuit. According to the evaluation result, the short circuit current can be early forecasted with the proposed method.
基金Supported by Project of the National Natural Science Foundation of China(50375053,50575077)
文摘Based on the phase space reconstruction of welding current in short-circuiting transfer arc welding under carbon dioxide, the approximate entropy of welding current and its standard deviation have been calculated and analyzed at different welding speeds and different electrode extensions respectively. The experimental and calculated results show that at a certain arc voltage, wire feeding rate and gas flow rate, welding speed and electrode extension have significant effects not only on the approximate entropy of welding current, but also on the stability of welding process. Further analysis proves that when the welding speed and electrode extension are in an appropriate range respectively, the welding current approximate entropy attains maximum and its standard deviation minimum. Just under such circumstances, the welding process is in the most stable state.
文摘By means of high-speed photograph and synchronous oscillograph, the appearance and technical features of non-explosive short circuiting transfer using basic electrodes are investigated, and the conditions to form this metal transfer mode are discussed. It is shown that the metal transfer mode has its high frequency of droplet, short period of arc extinguishing and long arc igniting period. This metal transfer mode is expected for basic electrodes for its less spatter and higher deposition efficiency.
基金supported by the National Natural Science Foundation of China(Grant No.51665016)founded by the China Scholarship Council(Grant No.201508360113)
文摘In order to detecting and tracking along the weld seam with rotating arc sensor in underwater welding,the highpressure water environment rotating arc welding hardware platform is established and welding experiments using rotating arc sensor is done. Different radius of rotating arc sensor is used. And the corresponding welding current and voltage is obtained,which is compared with the results of rotating arc sensor short-circuit process simulation model under high-pressure water environment established in this article. The results show that under high-pressure water environment,rotating arc radius should be optimized,otherwise the short-circuit-arcing cycle will transit to a short-circuit-arcing-abruption cycle,making the welding quality poor. At last the critical radius between the short-circuit-arcing cycle and short-circuit-arcing-abruption cycle under high-pressure water environment is obtained.