期刊文献+
共找到74篇文章
< 1 2 4 >
每页显示 20 50 100
Nuclear Magnetic Resonance Measurements of Original Water Saturation and Mobile Water Saturation in Low Permeability Sandstone Gas 被引量:9
1
作者 高树生 叶礼友 +2 位作者 熊伟 郭和坤 胡志明 《Chinese Physics Letters》 SCIE CAS CSCD 2010年第12期217-218,共2页
We use nuclear magnetic resonance (NMR) and centrifugation to measure the original water saturation and mobile water saturation of cores from the Xujiahe low permeability sandstone gas reservoir, and compare the NMR... We use nuclear magnetic resonance (NMR) and centrifugation to measure the original water saturation and mobile water saturation of cores from the Xujiahe low permeability sandstone gas reservoir, and compare the NMR results with the corresponding field data. It is shown that the NMR water saturation after 300psi centrifugation effectively represents the original water saturation measured by weighing fresh cores. There is a good correlation between mobile water saturation and the water production performance of the corresponding gas wells. The critical mobile water saturation whether reservoir produces water of the Xujiahe low permeability sandstone gas is 6%. The higher the mobile water saturation, the greater the water production rate of gas well. This indicates that well's water production performance can be forecasted by mobile water saturation of cores. 展开更多
关键词 Instrumentation and measurement Plasma physics
原文传递
生产率损失测量工具的比较研究 被引量:2
2
作者 周沛宇 席晓宇 《中国卫生资源》 北大核心 2022年第5期570-576,共7页
目的 比较可用于卫生技术评估中的生产率损失测量工具,厘清可用于卫生技术评估中的生产率损失测量工具的应用条件,以期为相关研究者在选择生产率损失的测量工具时提供参考。方法 检索PubMed、Web of Science、中国知网、万方、维普等中... 目的 比较可用于卫生技术评估中的生产率损失测量工具,厘清可用于卫生技术评估中的生产率损失测量工具的应用条件,以期为相关研究者在选择生产率损失的测量工具时提供参考。方法 检索PubMed、Web of Science、中国知网、万方、维普等中外数据库,检索时间从数据库建库至2021年11月,由2名研究者按照纳入与排除标准独立筛选文献、识别生产率损失测量工具、提取资料。结果 共识别出5种可用于卫生技术评估领域中的生产率损失测量工具,包括工作能力和活动受损量表(work productivity activity and impairment,WPAI)、工作能力局限调查问卷(work limitations questionnaire,WLQ)、健康与工作绩效问卷(Health and Work Performance Questionnaire,HPQ)、损失产能的估值(Valuation of Lost Productivity Questionnaire,VOLP)和医疗技术评估研究院(Institute for Medical Technology Assessment,IMTA)的生产力成本问卷(IMTA Productivity Questionnaire,IPCQ)。其中WPAI和WLQ是测量属性证据最为充足的工具;VOLP是成本涵盖最全的工具;WLQ是数据敏感性最强的工具;IPCQ是货币转化方法最多的工具;WPAI是获取使用最方便的工具。结论 对于卫生技术评估中的生产率损失测量的标准工具尚未存在统一共识,研究者可根据自身研究选取生产率损失测量工具。 展开更多
关键词 生产率损失productivity loss 间接成本indirect cost 测量工具measure instrument 卫生技术评估health technology assessment
暂未订购
Methodological quality(risk of bias)assessment tools for primary and secondary medical studies:What are they and which is better? 被引量:60
3
作者 Lin-Lu Ma Yun-Yun Wang +3 位作者 Zhi-Hua Yang Di Huang Hong Weng Xian-Tao Zeng 《Military Medical Research》 SCIE CAS CSCD 2020年第3期359-370,共12页
Methodological quality(risk of bias)assessment is an important step before study initiation usage.Therefore,accurately judging study type is the first priority,and the choosing proper tool is also important.In this re... Methodological quality(risk of bias)assessment is an important step before study initiation usage.Therefore,accurately judging study type is the first priority,and the choosing proper tool is also important.In this review,we introduced methodological quality assessment tools for randomized controlled trial(including individual and cluster),animal study,non-randomized interventional studies(including follow-up study,controlled before-and-after study,before-after/pre-post study,uncontrolled longitudinal study,interrupted time series study),cohort study,case-control study,cross-sectional study(including analytical and descriptive),observational case series and case reports,comparative effectiveness research,diagnostic study,health economic evaluation,prediction study(including predictor finding study,prediction model impact study,prognostic prediction model study),qualitative study,outcome measurement instruments(including patient-reported outcome measure development,content validity,structural validity,internal consistency,cross-cultural validity/measurement invariance,reliability,measurement error,criterion validity,hypotheses testing for construct validity,and responsiveness),systematic review and meta-analysis,and clinical practice guideline.The readers of our review can distinguish the types of medical studies and choose appropriate tools.In one word,comprehensively mastering relevant knowledge and implementing more practices are basic requirements for correctly assessing the methodological quality. 展开更多
关键词 Methodological quality Risk of bias Quality assessment Critical appraisal Methodology checklist Appraisal tool Observational study Qualitative study Interventional study Outcome measurement instrument
原文传递
INTELLIGENT VIRTUAL CONTROL:MEASURING INSTRUMENT FROM WHOLE TO PART 被引量:19
4
作者 Qin Shuren Tang BaopingCollege of Mechanical Engineering, Chongqing University, Chongqing 400044, China 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2002年第2期131-135,共5页
A new concept called intelligent virtual control (IVC), which can be drivenby measuring functions, is put forward. This small 'intelligent measurement instrument unit (IMIU)',carrying with functions of instrum... A new concept called intelligent virtual control (IVC), which can be drivenby measuring functions, is put forward. This small 'intelligent measurement instrument unit (IMIU)',carrying with functions of instrument, consists of different types of intelligent virtualinstrument (IVI) through individual components together as building blocks and can be displayeddirectly on the computer screen. This is a new concept of measuring instrument, and also animportant breakthrough after virtual instrument (VI). Virtual control makes instrument resourcesobtain further exploitation. It brings about a fundamental change to the design and manufacturingmode. The instrument therefore, can not only be produced directly inside a PC, but the product isinvolved in the 'green product' system. So far, all the present digital instruments will grow to bereplaced by intelligent control with green characteristics. 展开更多
关键词 Intelligent virtual control Measurement instrument Whole Part
在线阅读 下载PDF
Image motion and experimental study of a 0.1″space pointing measuring instrument for micro-vibration conditions 被引量:5
5
作者 Lin LI Li YUAN +5 位作者 Li WANG Miaomiao WANG Xiaoxue GONG Jie SUI Yanpeng WU Ran ZHENG 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2023年第2期191-200,共10页
There exists an increasing need for Milli-Arc-Seconds(MAS)accuracy pointing measurement for current and future space systems.To meet the 0.1″space pointing measurement accuracy requirements of spacecraft in future,th... There exists an increasing need for Milli-Arc-Seconds(MAS)accuracy pointing measurement for current and future space systems.To meet the 0.1″space pointing measurement accuracy requirements of spacecraft in future,the influence of spacecraft micro-vibration on a 0.1″Space Pointing Measuring Instrument(SPMI)is studied.A Quasi-Zero Stiffness Device(QZSD)with adaptive adjustment and variable stroke was proposed.Then,a series of micro-vibration experiments of the SPMI were carried out.The influence of the micro-vibration generated by Guidance Navigation Control(GNC)attitude control components under different attitudes on the SPMI was analyzed.Point spread function of image motion in micro-vibration was also derived.Further,the changes of image motion under the micro-vibration environment were evaluated by extracting the gray centroid of the images,and the experiment processes and results are deeply discussed.The results show that the firstorder frequency of the QZSD system is 0.114 Hz,and it is induced by a double pendulum system;the image motion of single flywheel spinning reached 0.015 pixels;whilst the image motion reached 0.03 pixels when three flywheels are combined spinning.These latest findings provide a beneficial theoretical and technical support for the development of spacecraft with 0·1″pointing accuracy. 展开更多
关键词 Image motion MICRO-VIBRATION Milli-arc-seconds Quasi-zero stiffness device Space pointing measuring instrument
原文传递
Accurate Phase Shift Extraction for Generalized Phase-Shifting Interferometry 被引量:7
6
作者 徐先锋 蔡履中 +1 位作者 王玉荣 李代林 《Chinese Physics Letters》 SCIE CAS CSCD 2010年第2期131-134,共4页
An accurate phase shift extraction method for generalized phase-shifting interferometry is suggested. Based on the nearly random phase distribution of the diffraction field of the object, a singular formula is derived... An accurate phase shift extraction method for generalized phase-shifting interferometry is suggested. Based on the nearly random phase distribution of the diffraction field of the object, a singular formula is derived to calculate the unknown phase shift without the requirements of an iteration process or the selection of the correct value from two or more possible phase shift solutions as needed before. This method can be used in the cases of two or more frames with both smooth and diffusing object surfaces. Computer simulations and optical experiments have satisfactorily verified the efficiency and accuracy of this method. 展开更多
关键词 Instrumentation and measurement Optics quantum optics and lasers
原文传递
Self-heating Probe Instrument and Method for Measuring High Temperature Melting Volume Change Rate of Material 被引量:2
7
作者 WANG Junwei WANG Zhiping +1 位作者 LU Yang CHENG Bo 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2013年第2期371-376,共6页
The castings defects are affected by the melting volume change rate of material.The change rate has an important effect on running safety of the high temperature thermal storage chamber,too.But the characteristics of ... The castings defects are affected by the melting volume change rate of material.The change rate has an important effect on running safety of the high temperature thermal storage chamber,too.But the characteristics of existing measuring installations are complex structure,troublesome operation and low precision.In order to measure the melting volume change rate of material accurately and conveniently,a self-designed measuring instrument,self-heating probe instrument,and measuring method are described.Temperature in heating cavity is controlled by PID temperature controller;melting volume change rateυand molten density are calculated based on the melt volume which is measured by the instrument.Positive and negativeυrepresent expansion and shrinkage of the sample volume after melting,respectively.Taking eutectic LiF+CaF2 for example,its melting volume change rate and melting density at 1123 K are-20.6%and 2651 kg/m–3 measured by this instrument,which is only 0.71%smaller than literature value.Density and melting volume change rate of industry pure aluminum at 973 K and analysis pure NaCl at 1123 K are detected by the instrument too.The measure results are agreed with report values.Measuring error sources are analyzed and several improving measures are proposed.In theory,the measuring errors of the change rate and molten density which are measured by the self-designed instrument is nearly 1/20-1/50 of that measured by the refitted mandril thermal expansion instrument.The self-designed instrument and method have the advantages of simple structure,being easy to operate,extensive applicability for material,relatively high accuracy,and most importantly,temperature and sample vapor pressure have little effect on the measurement accuracy.The presented instrument and method solve the problems of complicated structure and procedures,and large measuring errors for the samples with high vapor pressure by existing installations. 展开更多
关键词 high temperature volume expansion rate molten density measuring instrument measuring method
在线阅读 下载PDF
Fabrication of Dry Electrode for Recording Bio-potentials 被引量:2
8
作者 WANG Yu GUO Kai +4 位作者 PEI Wei-Hua GUI Qiang LI Xiao-Qian CHEN Hong-Da YANG Jian-Hong 《Chinese Physics Letters》 SCIE CAS CSCD 2011年第1期47-49,共3页
Development of minimally invasive dry electrodes for recording biopotentials is presented. The detailed fabrication process is outlined. A dry electrode is formed by a number of microneedles. The lengths of the micron... Development of minimally invasive dry electrodes for recording biopotentials is presented. The detailed fabrication process is outlined. A dry electrode is formed by a number of microneedles. The lengths of the microneedles are about 150μm and the diameters are about 50μm. The tips of the microneedles are sharp enough to penetrate into the skin. The silver/silver chloride is grown on microneedle arrays and demonstrates good character. The electrocardiogram shows that the dry electrode is suitable for recording biopotentials. 展开更多
关键词 Instrumentation and measurement Medical physics Biological physics
原文传递
Analysis of Detectors and Transmission Curve Correction of Mobile Rayleigh Doppler Wind Lidar 被引量:3
9
作者 唐磊 汪永涛 +8 位作者 舒志峰 董吉辉 王国成 徐文静 胡冬冬 陈廷娣 窦贤康 孙东松 CHA Hyunki 《Chinese Physics Letters》 SCIE CAS CSCD 2010年第11期99-102,共4页
A mobile molecular Doppler wind lidar (DWL) based on double-edge technique is presented for wind measurement at altitudes from 10 km to 40 km. A triple Fabry-Perot etalon is employed as a frequency discriminator to ... A mobile molecular Doppler wind lidar (DWL) based on double-edge technique is presented for wind measurement at altitudes from 10 km to 40 km. A triple Fabry-Perot etalon is employed as a frequency discriminator to determine the Doppler shift proportional to the wind velocity. The lidar operates at 355 nm with a 45-cm aperture telescope and a matching azimuth-over-elevation scanner that can provide full hemispherical pointing. In order to guarantee the wind accuracy, different forms of calibration function of detectors in different count rates response range would be especially valuable. The accuracy of wind velocity iteration is improved greatly because of application of the calibration function of linearity at the ultra low light intensity especially at altitudes from 10 km to 40 km. The calibration functions of nonlinearity make the transmission of edge channel 1 and edge channel 2 increase 38.9% and 27.7% at about 1 M count rates, respectively. The dynamic range of wind field measurement may also be extended because of consideration of the response function of detectors in their all possible operating range. 展开更多
关键词 Instrumentation and measurement Optics quantum optics and lasers Environmental and Earth science
原文传递
Effect of Vortex Stirring on the Dilution of Copper Slag 被引量:2
10
作者 ZHANG Baojing ZHANG Tingan +1 位作者 DOU Zhihe ZHANG Dongliang 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2022年第4期699-706,共8页
In order to solve the problem that the vulcanizing agent utilization rate is low and the dilution effect of copper slag is poor,the vortex stirring dilution method was used to improve the conditions of the dilution ki... In order to solve the problem that the vulcanizing agent utilization rate is low and the dilution effect of copper slag is poor,the vortex stirring dilution method was used to improve the conditions of the dilution kinetics and copper recovery.The water model was used to simulate the effect of copper slag dilution.Under the premise of keeping the Reynolds number consistent,silicone oil and glass beads were used instead of copper slag and vulcanizing agent.Based on the relationship between voltage and concentration,the PC6D dual-channel particle concentration measuring instrument was used to study the stirring speed and the insertion depth of the stirring paddle in model experiments,and the suitable conditions were speed 250 rpm and insertion depth 70 mm.The fire dilution of copper slag was done under the conditions.After stirring and sedimentation,the Fe_(3)O_(4) in slag decreased from 22.58% to 4.65%,and the copper content of the slag decreased from 2.94% to 0.34%.The copper recovery was 88.44%. 展开更多
关键词 copper slag dilution vortex stirring water model the PC6D dual-channel particle concentration measuring instrument
原文传递
Theoretical Investigation of Femtosecond-Resolved Photoelectron Spectra of the Li2 Molecule 被引量:5
11
作者 刘玉芳 刘瑞琼 丁俊霞 《Chinese Physics Letters》 SCIE CAS CSCD 2009年第7期107-110,共4页
The time-dependent quantum wave packet method is used to investigate the dynamics for the Li2 molecule, and the time-resolved photoelectron spectra (TRPES) of the Li2 molecule are calculated. At the short delay time... The time-dependent quantum wave packet method is used to investigate the dynamics for the Li2 molecule, and the time-resolved photoelectron spectra (TRPES) of the Li2 molecule are calculated. At the short delay time, the particular phenomenon of TRPES with four peaks is qualitatively interpreted in a dressed state picture by analyzing wave packet motion on light-induced potential (LIP). The significant difference in the electronic structure of E1∑g^+ between the inner and outer turning points has an impact on the TRPES. The control for the first excited state A1∑u^+ of the initial wave packet is discussed. 展开更多
关键词 Atomic and molecular physics Instrumentation and measurement
原文传递
Higher Harmonics Generation in Tapping Mode Atomic Force Microscope 被引量:2
12
作者 李渊 钱建强 《Chinese Physics Letters》 SCIE CAS CSCD 2009年第10期72-74,共3页
The contribution of higher harmonics to the movement of a micro rectangular cantilever in tapping mode AFM is investigated. The dependence between the phase lag of the higher harmonic components and tip-sample separat... The contribution of higher harmonics to the movement of a micro rectangular cantilever in tapping mode AFM is investigated. The dependence between the phase lag of the higher harmonic components and tip-sample separation are found to be an order of magnitude higher than the base one, reflecting an increasing sensitivity to local variations of surface properties compared to the normal phase signal The strong correlation between the higher harmonic amplitude and average sample deformation implies that the higher harmonic amplitude can be taken to monitor the tapping force or as feedback variable to fulfill a constant repulsive force mode. 展开更多
关键词 Instrumentation and measurement Surfaces interfaces and thin films
原文传递
High-Quality Continuous-Wave Imaging with a 2.53 THz Optical Pumped Terahertz Laser and a Pyroelectric Detector 被引量:2
13
作者 邴丕彬 姚建铨 +2 位作者 徐德刚 徐小燕 李忠洋 《Chinese Physics Letters》 SCIE CAS CSCD 2010年第12期96-98,共3页
A cw terahertz (THz) transmission imaging system is demonstrated and a high-quality THz image can be obtained using a pyroelectric detector. The factors that affect the imaging quality, such as the THz wavelength, s... A cw terahertz (THz) transmission imaging system is demonstrated and a high-quality THz image can be obtained using a pyroelectric detector. The factors that affect the imaging quality, such as the THz wavelength, spot size on the sample surface, step length of the motor, and frequency of the chopper, are theoretically and experimentally investigated. The experimental results show that the maximum resolution of the THz image can reach 0.4mm with the THz wavelength of 118.8μm, the spot size of 1.8mm and the step length of 0.25mm. 展开更多
关键词 Instrumentation and measurement Optics quantum optics and lasers
原文传递
An Adaptive Fast Multipole Higher Order Boundary Element Method for Power Frequency Electric Field of Substation 被引量:2
14
作者 张占龙 邓军 +2 位作者 肖冬萍 何为 唐炬 《Chinese Physics Letters》 SCIE CAS CSCD 2010年第3期144-147,共4页
An adaptive fast multipole higher order boundary element method combining fast multipole (FM) with a higher order boundary element method is studied to solve the power frequency electric field (PFEF) of substation... An adaptive fast multipole higher order boundary element method combining fast multipole (FM) with a higher order boundary element method is studied to solve the power frequency electric field (PFEF) of substations. In this new technique, the iterative equation solver GMRES is used in the FM, where matrix-vector multiplications are calculated using fast multipole expansions. The coefficients in the preconditioner for GMRES are stored and are used repeatedly in the direct evaluations of the near-field contributions. Then a 500kV outdoor substation is modeled and the PFEF of the substation is analyzed by the novel algorithm and other conventional methods. The results show that, in computational cost and the storages capability aspects, the algorithm proposed in this study has obvious advantages. It is suitable for the calculation of the large-scale PFEF in complex substations and the design of electromagnetic compatibility. 展开更多
关键词 Computational physics Accelerators beams and electromagnetism Instrumentation and measurement
原文传递
Automatic Recognition Method for Optical Measuring Instruments Based on Machine Vision 被引量:2
15
作者 宋乐 林玉池 郝立果 《Transactions of Tianjin University》 EI CAS 2008年第3期202-207,共6页
Based on a comprehensive study of various algorithms, the automatic recognition of traditional ocular optical measuring instruments is realized. Taking a universal tools microscope(UTM) lens view image as an example, ... Based on a comprehensive study of various algorithms, the automatic recognition of traditional ocular optical measuring instruments is realized. Taking a universal tools microscope(UTM) lens view image as an example, a 2-layer automatic recognition model for data reading is established after adopting a series of pre-processing algorithms. This model is an optimal combination of the correlation-based template matching method and a concurrent back propagation(BP) neural network. Multiple complementary feature extraction is used in generating the eigenvectors of the concurrent network. In order to improve fault-tolerance capacity, rotation invariant features based on Zernike moments are extracted from digit characters and a 4-dimensional group of the outline features is also obtained. Moreover, the operating time and reading accuracy can be adjusted dy-namically by setting the threshold value. The experimental result indicates that the newly developed algorithm has optimal recognition precision and working speed. The average reading ratio can achieve 97.23%. The recognition method can automatically obtain the results of optical measuring instruments rapidly and stably without modifying their original structure, which meets the application requirements. 展开更多
关键词 automatic recognition optical measuring instruments template matching neural network
在线阅读 下载PDF
Analysis on the DNA Fingerprinting of Aspergillus Oryzae Mutant Induced by High Hydrostatic Pressure 被引量:1
16
作者 WANG Hua ZHANG Jian +5 位作者 YANG Fan WANG Kai SHEN Si-Le LIU Bing-Bing ZOU Bo ZOU Guang-Tian 《Chinese Physics Letters》 SCIE CAS CSCD 2011年第1期54-57,共4页
The mutant strains of aspergillus oryzae (HP300a) are screened under 300 MPa for 20min. Compared with the control strains, the screened mutant strains have unique properties such as genetic stability, rapid growth, ... The mutant strains of aspergillus oryzae (HP300a) are screened under 300 MPa for 20min. Compared with the control strains, the screened mutant strains have unique properties such as genetic stability, rapid growth, lots of spores, and high protease activity. Random amplified polymorphic DNA (RAPD) and inter simple sequence repeats (ISSR) are used to analyze the DNA fingerprinting of HP300a and the control strains. There are 67.9% and 51.3% polymorphic bands obtained by these two markers, respectively, indicating significant genetic variations between HP300a and the control strains. In addition, comparison of HP300a arid the control strains, the genetic distances of random sequence and simple sequence repeat of DNA are 0.51 and 0.34, respectively. 展开更多
关键词 Instrumentation and measurement Medical physics Biological physics
原文传递
Terahertz Direct Detection Characteristics of a Superconducting NbN Bolometer 被引量:1
17
作者 REN Yuan MIAO Wei +2 位作者 YAO Qi-Jun ZHANG Wen SHI Sheng-Cai 《Chinese Physics Letters》 SCIE CAS CSCD 2011年第1期50-53,共4页
We report the terahertz direct detection characteristics of a spiral antenna coupled NbN superconducting hot- electron bolometer (HEB) at a bath temperature of 4.2K. Thermal conductance determined from resistance tr... We report the terahertz direct detection characteristics of a spiral antenna coupled NbN superconducting hot- electron bolometer (HEB) at a bath temperature of 4.2K. Thermal conductance determined from resistance transition curves with different bias currents is found to be 3 × 10 7 W/K. The device shows a read-out circuit limited noise equivalent power (NEP) of 4.5 × 10-12 W/Hz/2 at 4.2 K with a home-made transimpedance amplifier operating at room temperature. 展开更多
关键词 SUPERCONDUCTIVITY Instrumentation and measurement
原文传递
Slow Light by Two-Dimensional Photonic Crystal Waveguides 被引量:1
18
作者 张超 黄俨 +4 位作者 毛晓宇 崔开宇 黄翊东 张巍 彭江得 《Chinese Physics Letters》 SCIE CAS CSCD 2009年第7期171-173,共3页
A simple and effective way to measure the group velocity ofphotonic crystal waveguides (PCWGs) is developed by using a fiber Mach-Zehnder interferometer. A PCWG with perfect air-bridge structure is fabricated and sl... A simple and effective way to measure the group velocity ofphotonic crystal waveguides (PCWGs) is developed by using a fiber Mach-Zehnder interferometer. A PCWG with perfect air-bridge structure is fabricated and slow light with group velocity slower than c/80 is demonstrated. 展开更多
关键词 Instrumentation and measurement Optics quantum optics and lasers
原文传递
Analysis of Optical Readout Sensitivity for Uncooled Infrared Detector 被引量:1
19
作者 程腾 张青川 +2 位作者 焦彬彬 陈大鹏 伍小平 《Chinese Physics Letters》 SCIE CAS CSCD 2009年第12期125-128,共4页
An optical readout uncooled infrared detector, employing a substrate-free focal plane array with pitch size 60μm, is established. The reflector deformation induced by the stress mismatching of the bi-layer structure ... An optical readout uncooled infrared detector, employing a substrate-free focal plane array with pitch size 60μm, is established. The reflector deformation induced by the stress mismatching of the bi-layer structure is discussed and, in turn, a universal solution to determine both the optical readout sensitivity and the optimal filter position is found. By applying this solution, the optical readout sensitivity for the ideal plane reflector could theoretically increase by 80% as compared with the conventional operation, and the sensitivity loss caused by the reflector deformation can also be reduced to a reasonable level. 展开更多
关键词 Electronics and devices Instrumentation and measurement Optics quantum optics and lasers
原文传递
Composite Scattering from the Electrically Very Large Ship-Sea Model Using the Hybrid High-Frequency Method 被引量:1
20
作者 罗伟 张民 +1 位作者 周平 殷红成 《Chinese Physics Letters》 SCIE CAS CSCD 2009年第11期63-65,共3页
A hybrid high-frequency method is proposed to analyze the bistatic electromagnetic scattering of the ship target on a very large two-dimensional randomly rough sea surface. The scattering of the ship-sea model is eva... A hybrid high-frequency method is proposed to analyze the bistatic electromagnetic scattering of the ship target on a very large two-dimensional randomly rough sea surface. The scattering of the ship-sea model is evaluated with the method of equivalent currents (MEC). The iterative physical optics method (IPO) is utilized to study the electromagnetic coupling effect caused by the hull and rough surface. The shadowing correction based on the Z-Buffer technology is introduced to eliminate the effects of the irrelevant scattering resources. The validity of the hybrid method is confirmed by the SAR simulation results and the scattering property of the ship-sea model is discussed. 展开更多
关键词 Instrumentation and measurement Optics quantum optics and lasers Environmental and Earth science
原文传递
上一页 1 2 4 下一页 到第
使用帮助 返回顶部