期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Single-Shot Measurement of Transient Phase Shift Induced by Laser Wake
1
作者 董军 卢宗贵 +8 位作者 张波 彭志涛 孙志红 夏彦文 元浩宇 唐军 朱德燕 刘华 吕嘉坤 《Chinese Physics Letters》 SCIE CAS CSCD 2017年第5期60-62,共3页
Based on the frequency-to-time mapping relation of the linearly chirped pulse, the temporal phase shift induced by a laser-excited wake in a helium gas jet is measured using a chirped-pulse spectral interferometry wi... Based on the frequency-to-time mapping relation of the linearly chirped pulse, the temporal phase shift induced by a laser-excited wake in a helium gas jet is measured using a chirped-pulse spectral interferometry with ~ 140 fs resolution over a temporal region of I ps in a single shot. In this measurement, the image of the wake is obtained with one-dimensional spatial resolution and temporal resolution limited only by the bandwidth and chirp of the pulse. The 'bubbles' feature of the wake structure, along with multiple wakes excited by the main lobe and the side lobe of a laser focal-spot, is captured simultaneously. 展开更多
关键词 Single-Shot Measurement of Transient Phase shift induced by Laser Wake
原文传递
Observation of Temperature Induced Plasma Frequency Shift in an Extremely Large Magnetoresistance Compound LaSb
2
作者 班文静 郭文婷 +1 位作者 雒建林 王楠林 《Chinese Physics Letters》 SCIE CAS CSCD 2017年第7期271-274,共4页
We report an optical spectroscopy study on LaSb, a compound recently identified to exhibit extremely large magnetoresistance. Our optieal measurement indicates that the material has a low carrier density. More inter- ... We report an optical spectroscopy study on LaSb, a compound recently identified to exhibit extremely large magnetoresistance. Our optieal measurement indicates that the material has a low carrier density. More inter- estingly, the study reveals that the plasma frequency increases with decreasing temperature. This phenomenon suggests either an increase of the conducting carrier density or/and a decrease of the effective mass of carriers with decreasing temperature. We attribute it primarily to the latter effect. Two possible scenarios on its physical origin are examined and discussed. The study offers new insight into the electronic structure of this compound. 展开更多
关键词 Observation of Temperature induced Plasma Frequency shift in an Extremely Large Magnetoresistance Compound LaSb
原文传递
The ^(13)C-NMR Study of the Conformation of L-Arginine in Aqueous Solution by Lanthanide Probes
3
作者 任吉民 裴奉奎 王文韵 《Journal of Rare Earths》 SCIE EI CAS CSCD 1991年第1期10-14,共5页
The heavy lanthanide ions(Dy,Ho,Er,Tm and Yb)were used to probe the conformation of L-arginine in aqueous solution.The results showed that the contact contribution to the observed^(13)C paramagnetic shift is very smal... The heavy lanthanide ions(Dy,Ho,Er,Tm and Yb)were used to probe the conformation of L-arginine in aqueous solution.The results showed that the contact contribution to the observed^(13)C paramagnetic shift is very small for nuclei four or more bonds away from the bound lanthanide ion and it is significant for those in close proximity to the lanthanide ion.The overall conformation of L-arginine was established by fitting the calculated geometric factors for the corresponding experimental data.In the lanthanide-L-arginine complex,the whole backbone of the ligand is located outsite the zero-dipolar shift cone of the lanthanide ion with the carboxyl group selectively coordinated to the metal.The calculated RE-O distance is 0.21 nm for the bidentate coordination mode and the ligand is in an extended conformation in the solution with the molecular backbone corresponding to the trans form. 展开更多
关键词 Rare earth ^(13)C-NMR induced shift L-ARGININE CONFORMATION
在线阅读 下载PDF
Overlay mark optimization for thick-film resist overlay metrology
4
作者 朱亮 李杰 +2 位作者 周从树 顾以理 杨华岳 《Journal of Semiconductors》 EI CAS CSCD 北大核心 2009年第6期142-146,共5页
For thick resist implant layers,such as a high voltage P well and a deep N well,systematic and uncorrectable overlay residues brought about by the tapered resist profiles were found.It was found that the tapered profi... For thick resist implant layers,such as a high voltage P well and a deep N well,systematic and uncorrectable overlay residues brought about by the tapered resist profiles were found.It was found that the tapered profile is closely related to the pattern density.Potential solutions of the manufacturing problem include hardening the film solidness or balancing the exposure density.In this paper,instead of focusing on the process change methodology,we intend to solve the issue of the overlay metrology error from the perspective of the overlay mark design.Based on the comparison of the overlay performances between the proposed overlay mark and the original design,it is shown that the optimized overlay mark target achieves better performance in terms of profiles,dynamic precision,tool induced shift(TIS),and residues.Furthermore,five types of overlay marks with dummy bars are studied,and a recommendation for the overlay marks is given. 展开更多
关键词 overlay metrology error dynamic precision tool induced shift statistical process control depth of focus exposure latitude
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部