The vacuum volatilization kinetics of Pb in In-Pb solder was investigated.The results indicate a significant increase in the vacuum volatilization rates of Pb,25In-75Pb,40In-60Pb,and In with increasing temperatures fr...The vacuum volatilization kinetics of Pb in In-Pb solder was investigated.The results indicate a significant increase in the vacuum volatilization rates of Pb,25In-75Pb,40In-60Pb,and In with increasing temperatures from 923 to 1123 K,system pressure of 3 Pa and holding time of 30 min.The mass transfer coefficients and apparent activation energies of Pb and its alloys were determined at various temperatures.Additionally,a kinetics model was developed to describe Pb vacuum volatilization in high-temperature melts.It is obtained that the vapor mass transfer is the factor limiting the vacuum volatilization rates of Pb and In-Pb alloys under the above specified conditions.展开更多
基金financially supported by the Fundamental Research Project of Yunnan Province,China(Nos.202301AW070020,202201AT070229,202105AC160091,202202AB080018).
文摘The vacuum volatilization kinetics of Pb in In-Pb solder was investigated.The results indicate a significant increase in the vacuum volatilization rates of Pb,25In-75Pb,40In-60Pb,and In with increasing temperatures from 923 to 1123 K,system pressure of 3 Pa and holding time of 30 min.The mass transfer coefficients and apparent activation energies of Pb and its alloys were determined at various temperatures.Additionally,a kinetics model was developed to describe Pb vacuum volatilization in high-temperature melts.It is obtained that the vapor mass transfer is the factor limiting the vacuum volatilization rates of Pb and In-Pb alloys under the above specified conditions.