DV-Hop localization algorithm has greater localization error which estimates distance from an unknown node to the different anchor nodes by using estimated average size of a hop to achieve the location of the unknown ...DV-Hop localization algorithm has greater localization error which estimates distance from an unknown node to the different anchor nodes by using estimated average size of a hop to achieve the location of the unknown node.So an improved DV-Hop localization algorithm based on correctional average size of a hop,HDCDV-Hop algorithm,is proposed.The improved algorithm corrects the estimated distance between the unknown node and different anchor nodes based on fractional hop count information and relatively accurate coordinates of the anchor nodes information,and it uses the improved Differential Evolution algorithm to get the estimate location of unknown nodes so as to further reduce the localization error.Simulation results show that our proposed algorithm have lower localization error and higher localization accuracy compared with the original DV-Hop algorithm and other classical improved algorithms.展开更多
China is vigorously promoting the “whole county promotion” of distributed photovoltaics (DPVs). However, the high penetration rate of DPVs has brought problems such as voltage violation and power quality degradation...China is vigorously promoting the “whole county promotion” of distributed photovoltaics (DPVs). However, the high penetration rate of DPVs has brought problems such as voltage violation and power quality degradation to the distribution network, seriously affecting the safety and reliability of the power system. The traditional centralized control method of the distribution network has the problem of low efficiency, which is not practical enough in engineering practice. To address the problems, this paper proposes a cluster voltage control method for distributed photovoltaic grid-connected distribution network. First, it partitions the distribution network into clusters, and different clusters exchange terminal voltage information through a “virtual slack bus.” Then, in each cluster, based on the control strategy of “reactive power compensation first, active power curtailment later,” it employs an improved differential evolution (IDE) algorithm based on Cauchy disturbance to control the voltage. Simulation results in two different distribution systems show that the proposed method not only greatly improves the operational efficiency of the algorithm but also effectively controls the voltage of the distribution network, and maximizes the consumption capacity of DPVs based on qualified voltage.展开更多
基金supported by Fundamental Research Funds of Jilin University(No.SXGJQY2017-9,No.2017TD-19)the National Natural Science Foundation of China(No.61771219)
文摘DV-Hop localization algorithm has greater localization error which estimates distance from an unknown node to the different anchor nodes by using estimated average size of a hop to achieve the location of the unknown node.So an improved DV-Hop localization algorithm based on correctional average size of a hop,HDCDV-Hop algorithm,is proposed.The improved algorithm corrects the estimated distance between the unknown node and different anchor nodes based on fractional hop count information and relatively accurate coordinates of the anchor nodes information,and it uses the improved Differential Evolution algorithm to get the estimate location of unknown nodes so as to further reduce the localization error.Simulation results show that our proposed algorithm have lower localization error and higher localization accuracy compared with the original DV-Hop algorithm and other classical improved algorithms.
基金the National Key R&D Plan Program of China(Grant No.2022YFE0120700)the Special Fund for Science and Technology Innovation of Jiangsu Province(Grant No.BE2022610)Zhuhai Industry Core Technology and Key Project(Grant No.2220004002344).
文摘China is vigorously promoting the “whole county promotion” of distributed photovoltaics (DPVs). However, the high penetration rate of DPVs has brought problems such as voltage violation and power quality degradation to the distribution network, seriously affecting the safety and reliability of the power system. The traditional centralized control method of the distribution network has the problem of low efficiency, which is not practical enough in engineering practice. To address the problems, this paper proposes a cluster voltage control method for distributed photovoltaic grid-connected distribution network. First, it partitions the distribution network into clusters, and different clusters exchange terminal voltage information through a “virtual slack bus.” Then, in each cluster, based on the control strategy of “reactive power compensation first, active power curtailment later,” it employs an improved differential evolution (IDE) algorithm based on Cauchy disturbance to control the voltage. Simulation results in two different distribution systems show that the proposed method not only greatly improves the operational efficiency of the algorithm but also effectively controls the voltage of the distribution network, and maximizes the consumption capacity of DPVs based on qualified voltage.