Scintillator-mediated indirect X-ray detectors,which transduce high-energy X-ray photons into detectable visible light,underpin critical applications in medical diagnostics,non-destructive imaging,and high-energy phys...Scintillator-mediated indirect X-ray detectors,which transduce high-energy X-ray photons into detectable visible light,underpin critical applications in medical diagnostics,non-destructive imaging,and high-energy physics.Flexible scintillator films represent a transformative advancement for next-generation X-ray imaging,enabling conformal integration biological tissues and complex geometries.The pursuit of solution-processed scintillators with benchmark light yield,ultralow detection limit,and superior mechanical robustness constitutes the primary objective in this field.This review comprehensively analyzes emerging high-performance scintillators,including lanthanide-doped nanocrystals,organic emitters,perovskites,metal-organic frameworks(MOFs),atomically metal clusters,and metal-organic complexes,focusing on strategies to enhance radioluminescence yield,minimize detection limits,and achieve mechanical robustness.We elucidate carrier dynamics from exciton formation to radiative recombination,alongside advanced fabrication paradigms for flexible/stretchable films via polymer encapsulation and intrinsically flexible designs.The resulting devices demonstrate exceptional capabilities in static,dynamic,and multifunctional imaging under ultralow doses.Critical frontiers in radiation stability,artificial intelligence(AI)-accelerated material discovery,and light propagation engineering are outlined to guide future detector development.展开更多
Cemented paste backfill(CPB)is a technology that achieves safe mining by filling the goaf with waste rocks,tailings,and other materials.It is an inevitable choice to deal with the development of deep and highly diffic...Cemented paste backfill(CPB)is a technology that achieves safe mining by filling the goaf with waste rocks,tailings,and other materials.It is an inevitable choice to deal with the development of deep and highly difficult mines and meet the requirements of environmental protection and safety regulations.It promotes the development of a circular economy in mines through the development of lowgrade resources and the resource utilization of waste,and extends the service life of mines.The mass concentration of solid content(abbreviated as“concentration”)is a critical parameter for CPB.However,discrepancies often arise between the on-site measurements and the pre-designed values due to factors such as groundwater inflow and segregation within the goaf,which cannot be evaluated after the solidification of CPB.This paper innovatively provides an in-situ non-destructive approach to identify the real concentration of CPB after curing for certain days using hyperspectral imaging(HSI)technology.Initially,the spectral variation patterns under different concentration conditions were investigated through hyperspectral scanning experiments on CPB samples.The results demonstrate that as the CPB concentration increases from 61wt%to 73wt%,the overall spectral reflectance gradually increases,with two distinct absorption peaks observed at 1407 and 1917 nm.Notably,the reflectance at 1407 nm exhibited a strong linear relationship with the concentration.Subsequently,the K-nearest neighbors(KNN)and support vector machine(SVM)algorithms were employed to classify and identify different concentrations.The study revealed that,with the KNN algorithm,the highest accuracy was achieved when K(number of nearest neighbors)was 1,although this resulted in overfitting.When K=3,the model displayed the optimal balance between accuracy and stability,with an accuracy of 95.03%.In the SVM algorithm,the highest accuracy of 98.24%was attained with parameters C(regularization parameter)=200 and Gamma(kernel coefficient)=10.A comparative analysis of precision,accuracy,and recall further highlighted that the SVM provided superior stability and precision for identifying CPB concentration.Thus,HSI technology offers an effective solution for the in-situ,non-destructive monitoring of CPB concentration,presenting a promising approach for optimizing and controlling CPB characteristic parameters.展开更多
Aqueous zinc metal batteries(AZMBs)face significant challenges in achieving reversibility and cycling stability,primarily due to hydrogen evolution reactions(HER)and zinc dendrite growth.In this study,by employing car...Aqueous zinc metal batteries(AZMBs)face significant challenges in achieving reversibility and cycling stability,primarily due to hydrogen evolution reactions(HER)and zinc dendrite growth.In this study,by employing carefully designed cells that approximate the structural characteristics of practical batteries,we revisit this widely held view through in-operando X-ray radiography to examine zinc dendrite formation and HER under nearpractical operating conditions.While conventional understanding emphasizes the severity of these processes,our findings suggest that zinc dendrites and HER are noticeably less pronounced in dense,real-operation configurations compared to modified cells,possibly due to a more uniform electric field and the suppression of triple-phase boundaries.This study indicates that other components,such as degradation at the cathode current collector interface and configuration mismatches within the full cell,may also represent important barriers to the practical application of AZMBs,particularly during the early stages of electrodeposition.展开更多
Synaptic pruning is a crucial process in synaptic refinement,eliminating unstable synaptic connections in neural circuits.This process is triggered and regulated primarily by spontaneous neural activity and experience...Synaptic pruning is a crucial process in synaptic refinement,eliminating unstable synaptic connections in neural circuits.This process is triggered and regulated primarily by spontaneous neural activity and experience-dependent mechanisms.The pruning process involves multiple molecular signals and a series of regulatory activities governing the“eat me”and“don't eat me”states.Under physiological conditions,the interaction between glial cells and neurons results in the clearance of unnecessary synapses,maintaining normal neural circuit functionality via synaptic pruning.Alterations in genetic and environmental factors can lead to imbalanced synaptic pruning,thus promoting the occurrence and development of autism spectrum disorder,schizophrenia,Alzheimer's disease,and other neurological disorders.In this review,we investigated the molecular mechanisms responsible for synaptic pruning during neural development.We focus on how synaptic pruning can regulate neural circuits and its association with neurological disorders.Furthermore,we discuss the application of emerging optical and imaging technologies to observe synaptic structure and function,as well as their potential for clinical translation.Our aim was to enhance our understanding of synaptic pruning during neural development,including the molecular basis underlying the regulation of synaptic function and the dynamic changes in synaptic density,and to investigate the potential role of these mechanisms in the pathophysiology of neurological diseases,thus providing a theoretical foundation for the treatment of neurological disorders.展开更多
Mesenchymal stromal cell transplantation is an effective and promising approach for treating various systemic and diffuse diseases.However,the biological characteristics of transplanted mesenchymal stromal cells in hu...Mesenchymal stromal cell transplantation is an effective and promising approach for treating various systemic and diffuse diseases.However,the biological characteristics of transplanted mesenchymal stromal cells in humans remain unclear,including cell viability,distribution,migration,and fate.Conventional cell tracing methods cannot be used in the clinic.The use of superparamagnetic iron oxide nanoparticles as contrast agents allows for the observation of transplanted cells using magnetic resonance imaging.In 2016,the National Medical Products Administration of China approved a new superparamagnetic iron oxide nanoparticle,Ruicun,for use as a contrast agent in clinical trials.In the present study,an acute hemi-transection spinal cord injury model was established in beagle dogs.The injury was then treated by transplantation of Ruicun-labeled mesenchymal stromal cells.The results indicated that Ruicunlabeled mesenchymal stromal cells repaired damaged spinal cord fibers and partially restored neurological function in animals with acute spinal cord injury.T2*-weighted imaging revealed low signal areas on both sides of the injured spinal cord.The results of quantitative susceptibility mapping with ultrashort echo time sequences indicated that Ruicun-labeled mesenchymal stromal cells persisted stably within the injured spinal cord for over 4 weeks.These findings suggest that magnetic resonance imaging has the potential to effectively track the migration of Ruicun-labeled mesenchymal stromal cells and assess their ability to repair spinal cord injury.展开更多
Freezing of gait is a significant and debilitating motor symptom often observed in individuals with Parkinson's disease.Resting-state functional magnetic resonance imaging,along with its multi-level feature indice...Freezing of gait is a significant and debilitating motor symptom often observed in individuals with Parkinson's disease.Resting-state functional magnetic resonance imaging,along with its multi-level feature indices,has provided a fresh perspective and valuable insight into the study of freezing of gait in Parkinson's disease.It has been revealed that Parkinson's disease is accompanied by widespread irregularities in inherent brain network activity.However,the effective integration of the multi-level indices of resting-state functional magnetic resonance imaging into clinical settings for the diagnosis of freezing of gait in Parkinson's disease remains a challenge.Although previous studies have demonstrated that radiomics can extract optimal features as biomarkers to identify or predict diseases,a knowledge gap still exists in the field of freezing of gait in Parkinson's disease.This cross-sectional study aimed to evaluate the ability of radiomics features based on multi-level indices of resting-state functional magnetic resonance imaging,along with clinical features,to distinguish between Parkinson's disease patients with and without freezing of gait.We recruited 28 patients with Parkinson's disease who had freezing of gait(15 men and 13 women,average age 63 years)and 30 patients with Parkinson's disease who had no freezing of gait(16 men and 14 women,average age 64 years).Magnetic resonance imaging scans were obtained using a 3.0T scanner to extract the mean amplitude of low-frequency fluctuations,mean regional homogeneity,and degree centrality.Neurological and clinical characteristics were also evaluated.We used the least absolute shrinkage and selection operator algorithm to extract features and established feedforward neural network models based solely on resting-state functional magnetic resonance imaging indicators.We then performed predictive analysis of three distinct groups based on resting-state functional magnetic resonance imaging indicators indicators combined with clinical features.Subsequently,we conducted 100 additional five-fold cross-validations to determine the most effective model for each classification task and evaluated the performance of the model using the area under the receiver operating characteristic curve.The results showed that when differentiating patients with Parkinson's disease who had freezing of gait from those who did not have freezing of gait,or from healthy controls,the models using only the mean regional homogeneity values achieved the highest area under the receiver operating characteristic curve values of 0.750(with an accuracy of 70.9%)and 0.759(with an accuracy of 65.3%),respectively.When classifying patients with Parkinson's disease who had freezing of gait from those who had no freezing of gait,the model using the mean amplitude of low-frequency fluctuation values combined with two clinical features achieved the highest area under the receiver operating characteristic curve of 0.847(with an accuracy of 74.3%).The most significant features for patients with Parkinson's disease who had freezing of gait were amplitude of low-frequency fluctuation alterations in the left parahippocampal gyrus and two clinical characteristics:Montreal Cognitive Assessment and Hamilton Depression Scale scores.Our findings suggest that radiomics features derived from resting-state functional magnetic resonance imaging indices and clinical information can serve as valuable indices for the identification of freezing of gait in Parkinson's disease.展开更多
Objective To qualitatively assess the diagnostic performance of dynamic contrast enhancement(DCE),diffusionweighted imaging(DWI),and T2-weighted imaging(T2WI),alone or in combination,in the evaluation of breast cancer...Objective To qualitatively assess the diagnostic performance of dynamic contrast enhancement(DCE),diffusionweighted imaging(DWI),and T2-weighted imaging(T2WI),alone or in combination,in the evaluation of breast cancer.Methods We retrospectively reviewed the records of 394 consecutive patients with pathologically confirmed breast lesions who had undergone 3-T magnetic resonance imaging(MRI).The morphological characteristics of breast lesions were evaluated using DCE,DWI,and T2WI based on BI-RADS lexicon descriptors by trained radiologists.Patients were categorized into mass and non-mass groups based on MRI characteristics of the lesions,and the differences between benign and malignant lesions in each group were compared.Clinical prediction models for breast cancer diagnosis were constructed using logistic regression analysis.Diagnostic efficacies were compared using the area under the receiver operating characteristic curve(AUC)and DeLong test.Results For mass-like lesions,all the morphological parameters significantly differentiated benign and malignant lesions on consensus DCE,DWI,and T2WI(P<0.05).The combined method(DCE+DWI+T2WI)had a higher AUC(0.865)than any of the individual modality(DCE:0.786;DWI:0.793;T2WI:0.809)(P<0.05).For non-mass-like lesions,DWI signal intensity was a significant predictor of malignancy(P=0.036),but the model using DWI alone had a low AUC(0.669).Conclusion Morphological assessment using the combination of DCE,DWI,and T2WI provides better diagnostic value in differentiating benign and malignant breast mass-like lesions than assessment with only one of the modalities.展开更多
A phase-aware cross-modal framework is presented that synthesizes UWF_FA from non-invasive UWF_RI for diabetic retinopathy(DR)stratification.A curated cohort of 1198 patients(2915 UWF_RI and 17,854 UWF_FA images)with ...A phase-aware cross-modal framework is presented that synthesizes UWF_FA from non-invasive UWF_RI for diabetic retinopathy(DR)stratification.A curated cohort of 1198 patients(2915 UWF_RI and 17,854 UWF_FA images)with strict registration quality supports training across three angiographic phases(initial,mid,final).The generator is based on a modified pix2pixHD with an added Gradient Variance Loss to better preserve microvasculature,and is evaluated using MAE,PSNR,SSIM,and MS-SSIM on held-out pairs.Quantitatively,the mid phase achieves the lowestMAE(98.76±42.67),while SSIM remains high across phases.Expert reviewshows substantial agreement(Cohen's κ=0.78–0.82)and Turing-stylemisclassification of 50%–70%of synthetic images as real,indicating strong perceptual realism.For downstream DR stratification,fusing multi-phase synthetic UWF_FA with UWF_RI in a Swin Transformer classifier yields significant gains over a UWF_RI-only baseline,with the full-phase setting(Set D)reaching AUC=0.910 and accuracy=0.829.These results support synthetic UWF_FA as a scalable,non-invasive complement to dye-based angiography that enhances screening accuracy while avoiding injection-related risks.展开更多
Transforming a scattering medium into a lens for imaging very simple binary objects is possible;however,it remains challenging to image complex grayscale objects,let alone measure 3D continuous distribution objects.He...Transforming a scattering medium into a lens for imaging very simple binary objects is possible;however,it remains challenging to image complex grayscale objects,let alone measure 3D continuous distribution objects.Here,we propose and demonstrate the use of a ground glass diffuser as a scattering lens for imaging complex grayscale fringes,and we employ it to achieve microscopic structured light 3D imaging(MSL3DI).The ubiquitous property of the speckle patterns permits the exploitation of the scattering medium as an ultra-thin scattering lens with a variable focal length and a flexible working distance for microscale object measurement.The method provides a light,flexible,and cost-effective imaging device as an alternative to microscope objectives or telecentric lenses in conventional MSL3DI systems.We experimentally demonstrate that employing a scattering lens allows us to achieve relatively good phase information and robust 3D imaging from depth measurements,yielding measurement accuracy only marginally lower than that of a telecentric lens,typically within approximately 10μm.Furthermore,the scattering lens demonstrates robust performance even when the imaging distance exceeds the typical working distance of a telecentric lens.The proposed method facilitates the application of scattering imaging techniques,providing a more flexible solution for MSL3DI.展开更多
In this editorial,we comment on the article by Lambert et al,published in the recent issue of the World Journal of Radiology.The focus of the editorial is to explore the advancements in whole-body magnetic resonance i...In this editorial,we comment on the article by Lambert et al,published in the recent issue of the World Journal of Radiology.The focus of the editorial is to explore the advancements in whole-body magnetic resonance imaging(WB-MRI)techno-logy,its current clinical applications,and the challenges that must be addressed to fully realize its potential in oncological imaging.WB-MRI has emerged as a pivotal tool in oncological imaging,offering comprehensive disease assessment without ionizing radiation.Its applications span the detection of bone metastases,evaluation of hematologic malignancies,and staging of a wide range of cancers,including lymphoma,prostate,and breast cancers.Advanced techniques such as diffusion-weighted imaging have enhanced its diagnostic performance by pro-viding superior lesion-to-background contrast and quantitative metrics.Despite its diagnostic strengths,WB-MRI faces challenges in standardization,patient acceptance,and integration into clinical workflows.Variability in acquisition pro-tocols,hardware differences,and patient-related factors,such as anxiety and motion artifacts,have limited widespread adoption.Emerging guidelines like MET-RADS-P and ONCO-RADS aim to address these issues by promoting stan-dardized protocols tailored to specific clinical needs.This editorial explores the advancements in WB-MRI technology,its current clinical applications,and the barriers that must be overcome to maximize its utility.By addressing these cha-llenges and embracing standardization,WB-MRI holds the potential to redefine the landscape of oncological imaging,aligning diagnostic precision with modern treatment goals of reducing long-term patient risk.展开更多
BACKGROUND Cutaneous melanoma is an aggressive skin cancer with high metastatic potential.Accurate staging is critical to guide therapeutic strategies and improve prognosis.Whole-body magnetic resonance imaging(WB-MRI...BACKGROUND Cutaneous melanoma is an aggressive skin cancer with high metastatic potential.Accurate staging is critical to guide therapeutic strategies and improve prognosis.Whole-body magnetic resonance imaging(WB-MRI),particularly when combined with diffusion-weighted imaging(DWI),has emerged as promising tool for comprehensive,radiation-free assessment of metastatic spread.AIM To systematically review the diagnostic performance and clinical utility of WBMRI in the staging and restaging of cutaneous melanoma,with comparison to conventional imaging modalities such as computed tomography(CT)and positron emission tomography/CT(PET/CT).METHODS A systematic literature review was conducted using PubMed,Embase,Scopus and Web of Science databases for studies published in the last 10 years.Inclusion criteria focused on comparative diagnostic accuracy studies of WB-MRI vs CT and PET/CT for melanoma staging.The methodological quality of the studies was appraised using the QUADAS-2 tool.RESULTS Sixteen studies involving over 700 patients met the inclusion criteria.WB-MRI showed high sensitivity(73%-90%)and specificity(up to 98%)in detecting metastases,particularly in bone,liver and soft tissue.DWI enhanced lesion detection,and WB-MRI often influenced clinical management decisions.However,CT outperformed WB-MRI in identifying small pulmonary nodules.AI-assisted analysis and contrastenhanced sequences further improved diagnostic confidence.CONCLUSION WB-MRI represents a robust imaging modality for staging cutaneous melanoma,offering superior soft-tissue contrast and functional imaging without ionizing radiation.Its strengths lie in detecting bone,liver and brain metastases.Challenges include limited lung lesion detection,cost,and availability.Advances in artificial intelligence,Hybrid PET/MRY systems,and radiomics are poised to expand WB-MRI’s role in personalized melanoma management.展开更多
BACKGROUND Photon-counting detector(PCD)CT represents a transformative advancement in radiological imaging,offering superior spatial resolution,enhanced contrast-tonoise ratio,and reduced radiation dose compared with ...BACKGROUND Photon-counting detector(PCD)CT represents a transformative advancement in radiological imaging,offering superior spatial resolution,enhanced contrast-tonoise ratio,and reduced radiation dose compared with the conventional energyintegrating detector CT.AIM To evaluate PCD CT in oncologic imaging,focusing on its role in tumor detection,staging,and treatment response assessment.METHODS We performed a systematic PubMed search from January 1,2017 to December 31,2024,using the keywords“photon-counting CT”,“cancer”,and“tumor”to identify studies on its use in oncologic imaging.We included experimental studies on humans or human phantoms and excluded reviews,commentaries,editorials,non-English,animal,and non-experimental studies.Study selection followed Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines.Out of 175 initial studies,39 met the inclusion criteria after screening and full-text review.Data extraction focused on study type,country of origin,and oncologic applications of photon-counting CT.No formal risk of bias assessment was performed,and the review was not registered in PROSPERO as it did not include a meta-analysis.RESULTS Key findings highlighted the advantages of PCD CT in imaging renal masses,adrenal adenomas,ovarian cancer,breast cancer,prostate cancer,pancreatic tumors,hepatocellular carcinoma,metastases,multiple myeloma,and lung cancer.Additionally,PCD CT has demonstrated improved lesion characterization and enhanced diagnostic accuracy in oncology.Despite its promising capabilities challenges related to data processing,storage,and accessibility remain.CONCLUSION As PCD CT technology evolves,its integration into routine oncologic imaging has the potential to significantly enhance cancer diagnosis and patient management.展开更多
In this editorial,a commentary on the article by Chang et al has been provided,the course of treatment of anorectal fistulas,especially complex and recurring ones,require accurate diagnostic procedures for determining...In this editorial,a commentary on the article by Chang et al has been provided,the course of treatment of anorectal fistulas,especially complex and recurring ones,require accurate diagnostic procedures for determining ideal surgical procedures.Conventional ways of imaging sometimes fall short,offering insufficient insights in aggravated instances.In this editorial,a novel application of hydrogen peroxide-enhanced magnetic resonance imaging(HP-MRI)that promises significant improvements in the imaging of anorectal fistula.Study is based on a retrospective investigation of 60 patients,contrasts the new HP-MRI with conventional diagnostic techniques such as physical examination,trans-perineal ultrasonography and poor spatial resolution MRI.The findings demonstrate HP-MRI's incredible diagnostic performance,with sensitivity and specificity rates of 96.08%and 90.91%,respectively,and unparalleled interobserver agreement(Kappa values ranging from 0.80 to 0.89).It has been a significant advancement for assessment of anorectal fistulas providing a better roadmap for surgical planning,lowering recurrence rates as well as reduced personal and financial burden on patients by reducing the need for repeated treatment and extended hospital stays.The remaining funds can be utilized for treatment of other medical need.Ultimately HP-MRI provides us a healthier&more efficient society by improvising patients well-being&optimized healthcare infrastructure.展开更多
This narrative review examines the use of imaging biomarkers for diagnosing and monitoring hydrocephalus from birth through childhood.Early detection and longitudinal follow-up are essential for guiding timely interve...This narrative review examines the use of imaging biomarkers for diagnosing and monitoring hydrocephalus from birth through childhood.Early detection and longitudinal follow-up are essential for guiding timely interventions and asse-ssing treatment outcomes.Cranial ultrasound and magnetic resonance imaging(MRI)are the primary imaging modalities,providing critical insights into ventri-cular size,cerebrospinal fluid dynamics,and neurodevelopmental implications.Key parameters,including Evans’index,Levene’s index,and the Cella Media index,as well as volumetric and diffusion-based MRI techniques,have been explored for their diagnostic and prognostic value.Advances in automated image analysis and artificial intelligence have further improved measurement precision and reproducibility.Despite these developments,challenges remain in standar-dizing imaging protocols and establishing normative reference values across different pediatric populations.This review highlights the strengths and limita-tions of current imaging approaches,emphasizing the need for consistent metho-dologies to enhance diagnostic accuracy and optimize patient management in hydrocephalus.展开更多
We present a prototype for hybrid Compton and positron emission tomography(PET)imaging aimed at enhancing data utilization and enabling concurrent imaging of multiple radiopharmaceuticals.The prototype comprises two d...We present a prototype for hybrid Compton and positron emission tomography(PET)imaging aimed at enhancing data utilization and enabling concurrent imaging of multiple radiopharmaceuticals.The prototype comprises two detectors that utilize LYSO-SiPM and were available in our laboratory.One detector consists of a 50×50 array of LYSO crystals,each measuring 0.9mm×0.9mm×10mm with 1 mm pitches,whereas the other detector comprises a 25×25 array of LYSO crystals,each measuring 1.9mm×1.9mm×10mm with 2 mm pitches.These detectors are mounted on a rotational stage,which enables them to function as either a Compton camera or a PET detector pair.The 64-channel signals from the SiPMs of each detector are processed through a capacitive multiplexing circuit to yield four position-weighted outputs.Distinct energy windows were used to discriminate Compton events from PET events.Energy resolution and energy-channel relationships were calibrated via multiple sources.The measured average energy resolutions(full widths at half maximum,FWHMs)for the detectors at 511 keV were 17.5%and 15.2%,respectively.The initial experimental results indicate an angular resolution(FWHM)of 8.6◦for the system in Compton imaging mode.A V-shaped tube injected with 18 F solution was clearly reconstructed,which further verified the imaging capabilities of the system in Compton imaging mode.The results of simulation and experimental imaging studies show that the system can detect tumors as small as 1 mm in diameter when working in PET imaging mode.Mouse bone PET imaging was successfully conducted,with the results matching well with the corresponding CT images.This technology holds great potential for advancing the development of physiological function modalities.展开更多
The rapid development of super-resolution microscopy has made it possible to observe subcellular structures and dynamic behaviors in living cells with nanoscale spatial resolution, greatly advancing progress in life s...The rapid development of super-resolution microscopy has made it possible to observe subcellular structures and dynamic behaviors in living cells with nanoscale spatial resolution, greatly advancing progress in life sciences. As hardware technology continues to evolve, the availability of new fluorescent probes with superior performance is becoming increasingly important. In recent years, fluorescent nanoprobes (FNPs) have emerged as highly promising fluorescent probes for bioimaging due to their high brightness and excellent photostability. This paper focuses on the development and applications of FNPs as probes for live-cell super-resolution imaging. It provides an overview of different super-resolution methods, discusses the performance requirements for FNPs in these methods, and reviews the latest applications of FNPs in the super-resolution imaging of living cells. Finally, it addresses the challenges and future outlook in this field.展开更多
Early correction of childhood malocclusion is timely managing morphological,structural,and functional abnormalities at different dentomaxillofacial developmental stages.The selection of appropriate imaging examination...Early correction of childhood malocclusion is timely managing morphological,structural,and functional abnormalities at different dentomaxillofacial developmental stages.The selection of appropriate imaging examination and comprehensive radiological diagnosis and analysis play an important role in early correction of childhood malocclusion.This expert consensus is a collaborative effort by multidisciplinary experts in dentistry across the nation based on the current clinical evidence,aiming to provide general guidance on appropriate imaging examination selection,comprehensive and accurate imaging assessment for early orthodontic treatment patients.展开更多
Perianal fistulising Crohn’s disease is a challenging complication that can affect up to 20%of patients with Crohn’s disease and is associated with significant morbidity.Despite advances in medical therapies,particu...Perianal fistulising Crohn’s disease is a challenging complication that can affect up to 20%of patients with Crohn’s disease and is associated with significant morbidity.Despite advances in medical therapies,particularly anti-tumor necrosis factor agents,the majority of patients still require surgical intervention.Accurate diagnosis and monitoring are essential to optimise outcomes and guide multidisciplinary management.Although clinical scoring systems such as the perianal disease activity index are widely used,their subjective application limits their reproducibility and reliability,underscoring the need for more objective methods of evaluating perianal fistulising Crohn’s disease activity.Imaging has thus become central to the objective assessment of perianal fistulising Crohn’s disease,with magnetic resonance imaging(MRI)recognised as the gold standard in view of its ability to provide clear,detailed images of the perianal region in a radiation-free manner.Guidelines also endorse the use of imaging modalities such as endoanal ultrasound and transperineal ultrasound as viable alternatives to MRI for the assessment of perianal fistulising Crohn’s disease in centres with appropriate expertise.This article aims to evaluate and compare the diagnostic accuracy and clinical utility of MRI,endoanal ultrasound,and transperineal ultrasound in the assessment of perianal fistulising Crohn’s disease,highlighting their respective strengths,limitations,and roles in clinical practice.展开更多
The presence of a positive deep surgical margin in tongue squamous cell carcinoma(TSCC)significantly elevates the risk of local recurrence.Therefore,a prompt and precise intraoperative assessment of margin status is i...The presence of a positive deep surgical margin in tongue squamous cell carcinoma(TSCC)significantly elevates the risk of local recurrence.Therefore,a prompt and precise intraoperative assessment of margin status is imperative to ensure thorough tumor resection.In this study,we integrate Raman imaging technology with an artificial intelligence(AI)generative model,proposing an innovative approach for intraoperative margin status diagnosis.This method utilizes Raman imaging to swiftly and non-invasively capture tissue Raman images,which are then transformed into hematoxylin-eosin(H&E)-stained histopathological images using an AI generative model for histopathological diagnosis.The generated H&E-stained images clearly illustrate the tissue’s pathological conditions.Independently reviewed by three pathologists,the overall diagnostic accuracy for distinguishing between tumor tissue and normal muscle tissue reaches 86.7%.Notably,it outperforms current clinical practices,especially in TSCC with positive lymph node metastasis or moderately differentiated grades.This advancement highlights the potential of AI-enhanced Raman imaging to significantly improve intraoperative assessments and surgical margin evaluations,promising a versatile diagnostic tool beyond TSCC.展开更多
BACKGROUND Transcatheter arterial chemoembolization(TACE)is a key treatment approach for advanced invasive liver cancer(infiltrative hepatocellular carcinoma).However,its therapeutic response can be difficult to evalu...BACKGROUND Transcatheter arterial chemoembolization(TACE)is a key treatment approach for advanced invasive liver cancer(infiltrative hepatocellular carcinoma).However,its therapeutic response can be difficult to evaluate accurately using conventional two-dimensional imaging criteria due to the tumor’s diffuse and multifocal growth pattern.Volumetric imaging,especially enhanced tumor volume(ETV),offers a more comprehensive assessment.Nonetheless,bias field inhomogeneity in magnetic resonance imaging(MRI)poses challenges,potentially skewing volumetric measurements and undermining prognostic evaluation.AIM To investigate whether MRI bias field correction enhances the accuracy of volumetric assessment of infiltrative hepatocellular carcinoma treated with TACE,and to analyze how this improved measurement impacts prognostic prediction.METHODS We retrospectively collected data from 105 patients with invasive liver cancer who underwent TACE treatment at the Affiliated Hospital of Xuzhou Medical University from January 2020 to January 2024.The improved N4 bias field correction algorithm was applied to process MRI images,and the ETV before and after treatment was calculated.The ETV measurements before and after correction were compared,and their relationship with patient prognosis was analyzed.A Cox proportional hazards model was used to evaluate prognostic factors,with Martingale residual analysis determining the optimal cutoff value,followed by survival analysis.RESULTS Bias field correction significantly affected ETV measurements,with the corrected baseline ETV mean(505.235 cm^(3))being significantly lower than before correction(825.632 cm^(3),P<0.001).Cox analysis showed that the hazard ratio(HR)for corrected baseline ETV(HR=1.165,95%CI:1.069-1.268)was higher than before correction(HR=1.063,95%CI:1.031-1.095).Using 412 cm^(3) as the cutoff,the group with baseline ETV<415 cm^(3) had a longer median survival time compared to the≥415 cm^(3) group(18.523 months vs 8.926 months,P<0.001).The group with an ETV reduction rate≥41%had better prognosis than the<41%group(17.862 months vs 9.235 months,P=0.006).Multivariate analysis confirmed that ETV reduction rate(HR=0.412,P<0.001),Child-Pugh classification(HR=0.298,P<0.001),and Barcelona Clinic Liver Cancer stage(HR=0.578,P=0.045)were independent prognostic factors.CONCLUSION Volume imaging based on MRI bias field correction can improve the accuracy of evaluating the efficacy of TACE treatment for invasive liver cancer.The corrected ETV and its reduction rate can serve as independent indicators for predicting patient prognosis,providing important reference for developing individualized treatment strategies.展开更多
基金supported by the National Natural Science Foundation of China(Nos.52533008,22205104,22305127,and 21835003)the National Key Research and Development Program of China(Nos.2024YFB3612500,2024YFB3612600,and 2023YFB3608900)+2 种基金Basic Research Program of Jiangsu Province(No.BK20243057)Natural Science Research Start-up Foundation of Recruiting Talents of Nanjing University of Posts and Telecommunications(Nos.NY222078 and NY222079)Project of State Key Laboratory of Organic Electronics and Information Displays(Nos.GZR2023010031 and GZR2023010053).
文摘Scintillator-mediated indirect X-ray detectors,which transduce high-energy X-ray photons into detectable visible light,underpin critical applications in medical diagnostics,non-destructive imaging,and high-energy physics.Flexible scintillator films represent a transformative advancement for next-generation X-ray imaging,enabling conformal integration biological tissues and complex geometries.The pursuit of solution-processed scintillators with benchmark light yield,ultralow detection limit,and superior mechanical robustness constitutes the primary objective in this field.This review comprehensively analyzes emerging high-performance scintillators,including lanthanide-doped nanocrystals,organic emitters,perovskites,metal-organic frameworks(MOFs),atomically metal clusters,and metal-organic complexes,focusing on strategies to enhance radioluminescence yield,minimize detection limits,and achieve mechanical robustness.We elucidate carrier dynamics from exciton formation to radiative recombination,alongside advanced fabrication paradigms for flexible/stretchable films via polymer encapsulation and intrinsically flexible designs.The resulting devices demonstrate exceptional capabilities in static,dynamic,and multifunctional imaging under ultralow doses.Critical frontiers in radiation stability,artificial intelligence(AI)-accelerated material discovery,and light propagation engineering are outlined to guide future detector development.
基金funded by the National Natural Science Foundation of China(Nos.52474165 and 52522404)。
文摘Cemented paste backfill(CPB)is a technology that achieves safe mining by filling the goaf with waste rocks,tailings,and other materials.It is an inevitable choice to deal with the development of deep and highly difficult mines and meet the requirements of environmental protection and safety regulations.It promotes the development of a circular economy in mines through the development of lowgrade resources and the resource utilization of waste,and extends the service life of mines.The mass concentration of solid content(abbreviated as“concentration”)is a critical parameter for CPB.However,discrepancies often arise between the on-site measurements and the pre-designed values due to factors such as groundwater inflow and segregation within the goaf,which cannot be evaluated after the solidification of CPB.This paper innovatively provides an in-situ non-destructive approach to identify the real concentration of CPB after curing for certain days using hyperspectral imaging(HSI)technology.Initially,the spectral variation patterns under different concentration conditions were investigated through hyperspectral scanning experiments on CPB samples.The results demonstrate that as the CPB concentration increases from 61wt%to 73wt%,the overall spectral reflectance gradually increases,with two distinct absorption peaks observed at 1407 and 1917 nm.Notably,the reflectance at 1407 nm exhibited a strong linear relationship with the concentration.Subsequently,the K-nearest neighbors(KNN)and support vector machine(SVM)algorithms were employed to classify and identify different concentrations.The study revealed that,with the KNN algorithm,the highest accuracy was achieved when K(number of nearest neighbors)was 1,although this resulted in overfitting.When K=3,the model displayed the optimal balance between accuracy and stability,with an accuracy of 95.03%.In the SVM algorithm,the highest accuracy of 98.24%was attained with parameters C(regularization parameter)=200 and Gamma(kernel coefficient)=10.A comparative analysis of precision,accuracy,and recall further highlighted that the SVM provided superior stability and precision for identifying CPB concentration.Thus,HSI technology offers an effective solution for the in-situ,non-destructive monitoring of CPB concentration,presenting a promising approach for optimizing and controlling CPB characteristic parameters.
基金the fundamental Research Funds for the central Universities(x2wjD2240360)for the funding supportMeanwhile,Engineering and Physical Sciences Research Council(EPSRC,EP/V027433/3)+2 种基金UK Research and Innovation(UKRI)under the UK government’s Horizon Europe funding(101077226,EP/Y008707/1)Faraday Institution(EP/S003053/1)Degradation project(FIRG001),Royal Society(IEC\NSFC\233361),QUB Agility Fund and Wright Technology and Research Centre(W-Tech,R5240MEE)Funding from UK aid from the UK Government through the Faraday Institution and the Transforming Energy Access Programme(Grant number FIRG050-Device engineering of Zn-based hybrid micro-flow batteries and by-product H2 collection for Emerging Economies)。
文摘Aqueous zinc metal batteries(AZMBs)face significant challenges in achieving reversibility and cycling stability,primarily due to hydrogen evolution reactions(HER)and zinc dendrite growth.In this study,by employing carefully designed cells that approximate the structural characteristics of practical batteries,we revisit this widely held view through in-operando X-ray radiography to examine zinc dendrite formation and HER under nearpractical operating conditions.While conventional understanding emphasizes the severity of these processes,our findings suggest that zinc dendrites and HER are noticeably less pronounced in dense,real-operation configurations compared to modified cells,possibly due to a more uniform electric field and the suppression of triple-phase boundaries.This study indicates that other components,such as degradation at the cathode current collector interface and configuration mismatches within the full cell,may also represent important barriers to the practical application of AZMBs,particularly during the early stages of electrodeposition.
基金supported by the National Natural Science Foundation of China,No.31760290,82160688the Key Development Areas Project of Ganzhou Science and Technology,No.2022B-SF9554(all to XL)。
文摘Synaptic pruning is a crucial process in synaptic refinement,eliminating unstable synaptic connections in neural circuits.This process is triggered and regulated primarily by spontaneous neural activity and experience-dependent mechanisms.The pruning process involves multiple molecular signals and a series of regulatory activities governing the“eat me”and“don't eat me”states.Under physiological conditions,the interaction between glial cells and neurons results in the clearance of unnecessary synapses,maintaining normal neural circuit functionality via synaptic pruning.Alterations in genetic and environmental factors can lead to imbalanced synaptic pruning,thus promoting the occurrence and development of autism spectrum disorder,schizophrenia,Alzheimer's disease,and other neurological disorders.In this review,we investigated the molecular mechanisms responsible for synaptic pruning during neural development.We focus on how synaptic pruning can regulate neural circuits and its association with neurological disorders.Furthermore,we discuss the application of emerging optical and imaging technologies to observe synaptic structure and function,as well as their potential for clinical translation.Our aim was to enhance our understanding of synaptic pruning during neural development,including the molecular basis underlying the regulation of synaptic function and the dynamic changes in synaptic density,and to investigate the potential role of these mechanisms in the pathophysiology of neurological diseases,thus providing a theoretical foundation for the treatment of neurological disorders.
基金supported by the National Key R&D Program of China,Nos.2017YFA0104302(to NG and XM)and 2017YFA0104304(to BW and ZZ)
文摘Mesenchymal stromal cell transplantation is an effective and promising approach for treating various systemic and diffuse diseases.However,the biological characteristics of transplanted mesenchymal stromal cells in humans remain unclear,including cell viability,distribution,migration,and fate.Conventional cell tracing methods cannot be used in the clinic.The use of superparamagnetic iron oxide nanoparticles as contrast agents allows for the observation of transplanted cells using magnetic resonance imaging.In 2016,the National Medical Products Administration of China approved a new superparamagnetic iron oxide nanoparticle,Ruicun,for use as a contrast agent in clinical trials.In the present study,an acute hemi-transection spinal cord injury model was established in beagle dogs.The injury was then treated by transplantation of Ruicun-labeled mesenchymal stromal cells.The results indicated that Ruicunlabeled mesenchymal stromal cells repaired damaged spinal cord fibers and partially restored neurological function in animals with acute spinal cord injury.T2*-weighted imaging revealed low signal areas on both sides of the injured spinal cord.The results of quantitative susceptibility mapping with ultrashort echo time sequences indicated that Ruicun-labeled mesenchymal stromal cells persisted stably within the injured spinal cord for over 4 weeks.These findings suggest that magnetic resonance imaging has the potential to effectively track the migration of Ruicun-labeled mesenchymal stromal cells and assess their ability to repair spinal cord injury.
基金supported by the National Natural Science Foundation of China,No.82071909(to GF)the Natural Science Foundation of Liaoning Province,No.2023-MS-07(to HL)。
文摘Freezing of gait is a significant and debilitating motor symptom often observed in individuals with Parkinson's disease.Resting-state functional magnetic resonance imaging,along with its multi-level feature indices,has provided a fresh perspective and valuable insight into the study of freezing of gait in Parkinson's disease.It has been revealed that Parkinson's disease is accompanied by widespread irregularities in inherent brain network activity.However,the effective integration of the multi-level indices of resting-state functional magnetic resonance imaging into clinical settings for the diagnosis of freezing of gait in Parkinson's disease remains a challenge.Although previous studies have demonstrated that radiomics can extract optimal features as biomarkers to identify or predict diseases,a knowledge gap still exists in the field of freezing of gait in Parkinson's disease.This cross-sectional study aimed to evaluate the ability of radiomics features based on multi-level indices of resting-state functional magnetic resonance imaging,along with clinical features,to distinguish between Parkinson's disease patients with and without freezing of gait.We recruited 28 patients with Parkinson's disease who had freezing of gait(15 men and 13 women,average age 63 years)and 30 patients with Parkinson's disease who had no freezing of gait(16 men and 14 women,average age 64 years).Magnetic resonance imaging scans were obtained using a 3.0T scanner to extract the mean amplitude of low-frequency fluctuations,mean regional homogeneity,and degree centrality.Neurological and clinical characteristics were also evaluated.We used the least absolute shrinkage and selection operator algorithm to extract features and established feedforward neural network models based solely on resting-state functional magnetic resonance imaging indicators.We then performed predictive analysis of three distinct groups based on resting-state functional magnetic resonance imaging indicators indicators combined with clinical features.Subsequently,we conducted 100 additional five-fold cross-validations to determine the most effective model for each classification task and evaluated the performance of the model using the area under the receiver operating characteristic curve.The results showed that when differentiating patients with Parkinson's disease who had freezing of gait from those who did not have freezing of gait,or from healthy controls,the models using only the mean regional homogeneity values achieved the highest area under the receiver operating characteristic curve values of 0.750(with an accuracy of 70.9%)and 0.759(with an accuracy of 65.3%),respectively.When classifying patients with Parkinson's disease who had freezing of gait from those who had no freezing of gait,the model using the mean amplitude of low-frequency fluctuation values combined with two clinical features achieved the highest area under the receiver operating characteristic curve of 0.847(with an accuracy of 74.3%).The most significant features for patients with Parkinson's disease who had freezing of gait were amplitude of low-frequency fluctuation alterations in the left parahippocampal gyrus and two clinical characteristics:Montreal Cognitive Assessment and Hamilton Depression Scale scores.Our findings suggest that radiomics features derived from resting-state functional magnetic resonance imaging indices and clinical information can serve as valuable indices for the identification of freezing of gait in Parkinson's disease.
文摘Objective To qualitatively assess the diagnostic performance of dynamic contrast enhancement(DCE),diffusionweighted imaging(DWI),and T2-weighted imaging(T2WI),alone or in combination,in the evaluation of breast cancer.Methods We retrospectively reviewed the records of 394 consecutive patients with pathologically confirmed breast lesions who had undergone 3-T magnetic resonance imaging(MRI).The morphological characteristics of breast lesions were evaluated using DCE,DWI,and T2WI based on BI-RADS lexicon descriptors by trained radiologists.Patients were categorized into mass and non-mass groups based on MRI characteristics of the lesions,and the differences between benign and malignant lesions in each group were compared.Clinical prediction models for breast cancer diagnosis were constructed using logistic regression analysis.Diagnostic efficacies were compared using the area under the receiver operating characteristic curve(AUC)and DeLong test.Results For mass-like lesions,all the morphological parameters significantly differentiated benign and malignant lesions on consensus DCE,DWI,and T2WI(P<0.05).The combined method(DCE+DWI+T2WI)had a higher AUC(0.865)than any of the individual modality(DCE:0.786;DWI:0.793;T2WI:0.809)(P<0.05).For non-mass-like lesions,DWI signal intensity was a significant predictor of malignancy(P=0.036),but the model using DWI alone had a low AUC(0.669).Conclusion Morphological assessment using the combination of DCE,DWI,and T2WI provides better diagnostic value in differentiating benign and malignant breast mass-like lesions than assessment with only one of the modalities.
基金funded by theDeanship of Research andGraduate Studies at King Khalid University through Large Research Project under grant number RGP2/417/46.
文摘A phase-aware cross-modal framework is presented that synthesizes UWF_FA from non-invasive UWF_RI for diabetic retinopathy(DR)stratification.A curated cohort of 1198 patients(2915 UWF_RI and 17,854 UWF_FA images)with strict registration quality supports training across three angiographic phases(initial,mid,final).The generator is based on a modified pix2pixHD with an added Gradient Variance Loss to better preserve microvasculature,and is evaluated using MAE,PSNR,SSIM,and MS-SSIM on held-out pairs.Quantitatively,the mid phase achieves the lowestMAE(98.76±42.67),while SSIM remains high across phases.Expert reviewshows substantial agreement(Cohen's κ=0.78–0.82)and Turing-stylemisclassification of 50%–70%of synthetic images as real,indicating strong perceptual realism.For downstream DR stratification,fusing multi-phase synthetic UWF_FA with UWF_RI in a Swin Transformer classifier yields significant gains over a UWF_RI-only baseline,with the full-phase setting(Set D)reaching AUC=0.910 and accuracy=0.829.These results support synthetic UWF_FA as a scalable,non-invasive complement to dye-based angiography that enhances screening accuracy while avoiding injection-related risks.
基金supported by the National Natural Science Foundation of China(Grant Nos.62275188 and 62505216)the Central Guidance on Local Science and Technology Development Fund(Grant No.YDZJSX2024D019)+1 种基金the International Scientific and Technological Cooperative Project in Shanxi Province(Grant No.202104041101009)the Natural Science Foundation of Shanxi Province of China through Research Project(Grant No.20210302123195).
文摘Transforming a scattering medium into a lens for imaging very simple binary objects is possible;however,it remains challenging to image complex grayscale objects,let alone measure 3D continuous distribution objects.Here,we propose and demonstrate the use of a ground glass diffuser as a scattering lens for imaging complex grayscale fringes,and we employ it to achieve microscopic structured light 3D imaging(MSL3DI).The ubiquitous property of the speckle patterns permits the exploitation of the scattering medium as an ultra-thin scattering lens with a variable focal length and a flexible working distance for microscale object measurement.The method provides a light,flexible,and cost-effective imaging device as an alternative to microscope objectives or telecentric lenses in conventional MSL3DI systems.We experimentally demonstrate that employing a scattering lens allows us to achieve relatively good phase information and robust 3D imaging from depth measurements,yielding measurement accuracy only marginally lower than that of a telecentric lens,typically within approximately 10μm.Furthermore,the scattering lens demonstrates robust performance even when the imaging distance exceeds the typical working distance of a telecentric lens.The proposed method facilitates the application of scattering imaging techniques,providing a more flexible solution for MSL3DI.
文摘In this editorial,we comment on the article by Lambert et al,published in the recent issue of the World Journal of Radiology.The focus of the editorial is to explore the advancements in whole-body magnetic resonance imaging(WB-MRI)techno-logy,its current clinical applications,and the challenges that must be addressed to fully realize its potential in oncological imaging.WB-MRI has emerged as a pivotal tool in oncological imaging,offering comprehensive disease assessment without ionizing radiation.Its applications span the detection of bone metastases,evaluation of hematologic malignancies,and staging of a wide range of cancers,including lymphoma,prostate,and breast cancers.Advanced techniques such as diffusion-weighted imaging have enhanced its diagnostic performance by pro-viding superior lesion-to-background contrast and quantitative metrics.Despite its diagnostic strengths,WB-MRI faces challenges in standardization,patient acceptance,and integration into clinical workflows.Variability in acquisition pro-tocols,hardware differences,and patient-related factors,such as anxiety and motion artifacts,have limited widespread adoption.Emerging guidelines like MET-RADS-P and ONCO-RADS aim to address these issues by promoting stan-dardized protocols tailored to specific clinical needs.This editorial explores the advancements in WB-MRI technology,its current clinical applications,and the barriers that must be overcome to maximize its utility.By addressing these cha-llenges and embracing standardization,WB-MRI holds the potential to redefine the landscape of oncological imaging,aligning diagnostic precision with modern treatment goals of reducing long-term patient risk.
文摘BACKGROUND Cutaneous melanoma is an aggressive skin cancer with high metastatic potential.Accurate staging is critical to guide therapeutic strategies and improve prognosis.Whole-body magnetic resonance imaging(WB-MRI),particularly when combined with diffusion-weighted imaging(DWI),has emerged as promising tool for comprehensive,radiation-free assessment of metastatic spread.AIM To systematically review the diagnostic performance and clinical utility of WBMRI in the staging and restaging of cutaneous melanoma,with comparison to conventional imaging modalities such as computed tomography(CT)and positron emission tomography/CT(PET/CT).METHODS A systematic literature review was conducted using PubMed,Embase,Scopus and Web of Science databases for studies published in the last 10 years.Inclusion criteria focused on comparative diagnostic accuracy studies of WB-MRI vs CT and PET/CT for melanoma staging.The methodological quality of the studies was appraised using the QUADAS-2 tool.RESULTS Sixteen studies involving over 700 patients met the inclusion criteria.WB-MRI showed high sensitivity(73%-90%)and specificity(up to 98%)in detecting metastases,particularly in bone,liver and soft tissue.DWI enhanced lesion detection,and WB-MRI often influenced clinical management decisions.However,CT outperformed WB-MRI in identifying small pulmonary nodules.AI-assisted analysis and contrastenhanced sequences further improved diagnostic confidence.CONCLUSION WB-MRI represents a robust imaging modality for staging cutaneous melanoma,offering superior soft-tissue contrast and functional imaging without ionizing radiation.Its strengths lie in detecting bone,liver and brain metastases.Challenges include limited lung lesion detection,cost,and availability.Advances in artificial intelligence,Hybrid PET/MRY systems,and radiomics are poised to expand WB-MRI’s role in personalized melanoma management.
文摘BACKGROUND Photon-counting detector(PCD)CT represents a transformative advancement in radiological imaging,offering superior spatial resolution,enhanced contrast-tonoise ratio,and reduced radiation dose compared with the conventional energyintegrating detector CT.AIM To evaluate PCD CT in oncologic imaging,focusing on its role in tumor detection,staging,and treatment response assessment.METHODS We performed a systematic PubMed search from January 1,2017 to December 31,2024,using the keywords“photon-counting CT”,“cancer”,and“tumor”to identify studies on its use in oncologic imaging.We included experimental studies on humans or human phantoms and excluded reviews,commentaries,editorials,non-English,animal,and non-experimental studies.Study selection followed Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines.Out of 175 initial studies,39 met the inclusion criteria after screening and full-text review.Data extraction focused on study type,country of origin,and oncologic applications of photon-counting CT.No formal risk of bias assessment was performed,and the review was not registered in PROSPERO as it did not include a meta-analysis.RESULTS Key findings highlighted the advantages of PCD CT in imaging renal masses,adrenal adenomas,ovarian cancer,breast cancer,prostate cancer,pancreatic tumors,hepatocellular carcinoma,metastases,multiple myeloma,and lung cancer.Additionally,PCD CT has demonstrated improved lesion characterization and enhanced diagnostic accuracy in oncology.Despite its promising capabilities challenges related to data processing,storage,and accessibility remain.CONCLUSION As PCD CT technology evolves,its integration into routine oncologic imaging has the potential to significantly enhance cancer diagnosis and patient management.
文摘In this editorial,a commentary on the article by Chang et al has been provided,the course of treatment of anorectal fistulas,especially complex and recurring ones,require accurate diagnostic procedures for determining ideal surgical procedures.Conventional ways of imaging sometimes fall short,offering insufficient insights in aggravated instances.In this editorial,a novel application of hydrogen peroxide-enhanced magnetic resonance imaging(HP-MRI)that promises significant improvements in the imaging of anorectal fistula.Study is based on a retrospective investigation of 60 patients,contrasts the new HP-MRI with conventional diagnostic techniques such as physical examination,trans-perineal ultrasonography and poor spatial resolution MRI.The findings demonstrate HP-MRI's incredible diagnostic performance,with sensitivity and specificity rates of 96.08%and 90.91%,respectively,and unparalleled interobserver agreement(Kappa values ranging from 0.80 to 0.89).It has been a significant advancement for assessment of anorectal fistulas providing a better roadmap for surgical planning,lowering recurrence rates as well as reduced personal and financial burden on patients by reducing the need for repeated treatment and extended hospital stays.The remaining funds can be utilized for treatment of other medical need.Ultimately HP-MRI provides us a healthier&more efficient society by improvising patients well-being&optimized healthcare infrastructure.
文摘This narrative review examines the use of imaging biomarkers for diagnosing and monitoring hydrocephalus from birth through childhood.Early detection and longitudinal follow-up are essential for guiding timely interventions and asse-ssing treatment outcomes.Cranial ultrasound and magnetic resonance imaging(MRI)are the primary imaging modalities,providing critical insights into ventri-cular size,cerebrospinal fluid dynamics,and neurodevelopmental implications.Key parameters,including Evans’index,Levene’s index,and the Cella Media index,as well as volumetric and diffusion-based MRI techniques,have been explored for their diagnostic and prognostic value.Advances in automated image analysis and artificial intelligence have further improved measurement precision and reproducibility.Despite these developments,challenges remain in standar-dizing imaging protocols and establishing normative reference values across different pediatric populations.This review highlights the strengths and limita-tions of current imaging approaches,emphasizing the need for consistent metho-dologies to enhance diagnostic accuracy and optimize patient management in hydrocephalus.
基金supported by the National Natural Science Foundation of China(No.12105018)the Beijing Nova Program(Nos.Z211100002121129 and 20230484413)the Beijing Normal University Start-up Grant(No.312232104).
文摘We present a prototype for hybrid Compton and positron emission tomography(PET)imaging aimed at enhancing data utilization and enabling concurrent imaging of multiple radiopharmaceuticals.The prototype comprises two detectors that utilize LYSO-SiPM and were available in our laboratory.One detector consists of a 50×50 array of LYSO crystals,each measuring 0.9mm×0.9mm×10mm with 1 mm pitches,whereas the other detector comprises a 25×25 array of LYSO crystals,each measuring 1.9mm×1.9mm×10mm with 2 mm pitches.These detectors are mounted on a rotational stage,which enables them to function as either a Compton camera or a PET detector pair.The 64-channel signals from the SiPMs of each detector are processed through a capacitive multiplexing circuit to yield four position-weighted outputs.Distinct energy windows were used to discriminate Compton events from PET events.Energy resolution and energy-channel relationships were calibrated via multiple sources.The measured average energy resolutions(full widths at half maximum,FWHMs)for the detectors at 511 keV were 17.5%and 15.2%,respectively.The initial experimental results indicate an angular resolution(FWHM)of 8.6◦for the system in Compton imaging mode.A V-shaped tube injected with 18 F solution was clearly reconstructed,which further verified the imaging capabilities of the system in Compton imaging mode.The results of simulation and experimental imaging studies show that the system can detect tumors as small as 1 mm in diameter when working in PET imaging mode.Mouse bone PET imaging was successfully conducted,with the results matching well with the corresponding CT images.This technology holds great potential for advancing the development of physiological function modalities.
基金supported by the following grants:National Natural Science Foundation of China(grant nos.92354305,32271428,and 32201132)National Key R&D Program of China(grant no.2022YFC3401100)+1 种基金Fund for Knowledge Innovation of Wuhan Science and Technology Bureau(grant no.2022020801010558)Director Fund of WNLO.
文摘The rapid development of super-resolution microscopy has made it possible to observe subcellular structures and dynamic behaviors in living cells with nanoscale spatial resolution, greatly advancing progress in life sciences. As hardware technology continues to evolve, the availability of new fluorescent probes with superior performance is becoming increasingly important. In recent years, fluorescent nanoprobes (FNPs) have emerged as highly promising fluorescent probes for bioimaging due to their high brightness and excellent photostability. This paper focuses on the development and applications of FNPs as probes for live-cell super-resolution imaging. It provides an overview of different super-resolution methods, discusses the performance requirements for FNPs in these methods, and reviews the latest applications of FNPs in the super-resolution imaging of living cells. Finally, it addresses the challenges and future outlook in this field.
基金supports by the National Natural Science Foundation of China(Nos.82201135)"2015"Cultivation Program for Reserve Talents for Academic Leaders of Nanjing Stomatological School,Medical School of Nanjing University(No.0223A204).
文摘Early correction of childhood malocclusion is timely managing morphological,structural,and functional abnormalities at different dentomaxillofacial developmental stages.The selection of appropriate imaging examination and comprehensive radiological diagnosis and analysis play an important role in early correction of childhood malocclusion.This expert consensus is a collaborative effort by multidisciplinary experts in dentistry across the nation based on the current clinical evidence,aiming to provide general guidance on appropriate imaging examination selection,comprehensive and accurate imaging assessment for early orthodontic treatment patients.
文摘Perianal fistulising Crohn’s disease is a challenging complication that can affect up to 20%of patients with Crohn’s disease and is associated with significant morbidity.Despite advances in medical therapies,particularly anti-tumor necrosis factor agents,the majority of patients still require surgical intervention.Accurate diagnosis and monitoring are essential to optimise outcomes and guide multidisciplinary management.Although clinical scoring systems such as the perianal disease activity index are widely used,their subjective application limits their reproducibility and reliability,underscoring the need for more objective methods of evaluating perianal fistulising Crohn’s disease activity.Imaging has thus become central to the objective assessment of perianal fistulising Crohn’s disease,with magnetic resonance imaging(MRI)recognised as the gold standard in view of its ability to provide clear,detailed images of the perianal region in a radiation-free manner.Guidelines also endorse the use of imaging modalities such as endoanal ultrasound and transperineal ultrasound as viable alternatives to MRI for the assessment of perianal fistulising Crohn’s disease in centres with appropriate expertise.This article aims to evaluate and compare the diagnostic accuracy and clinical utility of MRI,endoanal ultrasound,and transperineal ultrasound in the assessment of perianal fistulising Crohn’s disease,highlighting their respective strengths,limitations,and roles in clinical practice.
基金supported by the National Natural Science Foundation of China(Grant Nos.82272955 and 22203057)the Natural Science Foundation of Fujian Province(Grant No.2021J011361).
文摘The presence of a positive deep surgical margin in tongue squamous cell carcinoma(TSCC)significantly elevates the risk of local recurrence.Therefore,a prompt and precise intraoperative assessment of margin status is imperative to ensure thorough tumor resection.In this study,we integrate Raman imaging technology with an artificial intelligence(AI)generative model,proposing an innovative approach for intraoperative margin status diagnosis.This method utilizes Raman imaging to swiftly and non-invasively capture tissue Raman images,which are then transformed into hematoxylin-eosin(H&E)-stained histopathological images using an AI generative model for histopathological diagnosis.The generated H&E-stained images clearly illustrate the tissue’s pathological conditions.Independently reviewed by three pathologists,the overall diagnostic accuracy for distinguishing between tumor tissue and normal muscle tissue reaches 86.7%.Notably,it outperforms current clinical practices,especially in TSCC with positive lymph node metastasis or moderately differentiated grades.This advancement highlights the potential of AI-enhanced Raman imaging to significantly improve intraoperative assessments and surgical margin evaluations,promising a versatile diagnostic tool beyond TSCC.
文摘BACKGROUND Transcatheter arterial chemoembolization(TACE)is a key treatment approach for advanced invasive liver cancer(infiltrative hepatocellular carcinoma).However,its therapeutic response can be difficult to evaluate accurately using conventional two-dimensional imaging criteria due to the tumor’s diffuse and multifocal growth pattern.Volumetric imaging,especially enhanced tumor volume(ETV),offers a more comprehensive assessment.Nonetheless,bias field inhomogeneity in magnetic resonance imaging(MRI)poses challenges,potentially skewing volumetric measurements and undermining prognostic evaluation.AIM To investigate whether MRI bias field correction enhances the accuracy of volumetric assessment of infiltrative hepatocellular carcinoma treated with TACE,and to analyze how this improved measurement impacts prognostic prediction.METHODS We retrospectively collected data from 105 patients with invasive liver cancer who underwent TACE treatment at the Affiliated Hospital of Xuzhou Medical University from January 2020 to January 2024.The improved N4 bias field correction algorithm was applied to process MRI images,and the ETV before and after treatment was calculated.The ETV measurements before and after correction were compared,and their relationship with patient prognosis was analyzed.A Cox proportional hazards model was used to evaluate prognostic factors,with Martingale residual analysis determining the optimal cutoff value,followed by survival analysis.RESULTS Bias field correction significantly affected ETV measurements,with the corrected baseline ETV mean(505.235 cm^(3))being significantly lower than before correction(825.632 cm^(3),P<0.001).Cox analysis showed that the hazard ratio(HR)for corrected baseline ETV(HR=1.165,95%CI:1.069-1.268)was higher than before correction(HR=1.063,95%CI:1.031-1.095).Using 412 cm^(3) as the cutoff,the group with baseline ETV<415 cm^(3) had a longer median survival time compared to the≥415 cm^(3) group(18.523 months vs 8.926 months,P<0.001).The group with an ETV reduction rate≥41%had better prognosis than the<41%group(17.862 months vs 9.235 months,P=0.006).Multivariate analysis confirmed that ETV reduction rate(HR=0.412,P<0.001),Child-Pugh classification(HR=0.298,P<0.001),and Barcelona Clinic Liver Cancer stage(HR=0.578,P=0.045)were independent prognostic factors.CONCLUSION Volume imaging based on MRI bias field correction can improve the accuracy of evaluating the efficacy of TACE treatment for invasive liver cancer.The corrected ETV and its reduction rate can serve as independent indicators for predicting patient prognosis,providing important reference for developing individualized treatment strategies.