期刊文献+
共找到443,724篇文章
< 1 2 250 >
每页显示 20 50 100
A modified OMP method for multi-orbit three dimensional ISAR imaging of the space target 被引量:3
1
作者 JIANG Libing ZHENG Shuyu +2 位作者 YANG Qingwei YANG Peng WANG Zhuang 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2023年第4期879-893,共15页
The conventional two dimensional(2D)inverse synthetic aperture radar(ISAR)imaging fails to provide the targets'three dimensional(3D)information.In this paper,a 3D ISAR imaging method for the space target is propos... The conventional two dimensional(2D)inverse synthetic aperture radar(ISAR)imaging fails to provide the targets'three dimensional(3D)information.In this paper,a 3D ISAR imaging method for the space target is proposed based on mutliorbit observation data and an improved orthogonal matching pursuit(OMP)algorithm.Firstly,the 3D scattered field data is converted into a set of 2D matrix by stacking slices of the 3D data along the elevation direction dimension.Then,an improved OMP algorithm is applied to recover the space target's amplitude information via the 2D matrix data.Finally,scattering centers can be reconstructed with specific three dimensional locations.Numerical simulations are provided to demonstrate the effectiveness and superiority of the proposed 3D imaging method. 展开更多
关键词 three dimensional inverse synthetic aperture radar(3D ISAR)imaging space target improved orthogonal matching pursuit(OMP)algorithm scattering centers
在线阅读 下载PDF
Revolutionizing hepatobiliary surgery:Impact of three-dimensional imaging and virtual surgical planning on precision,complications,and patient outcomes
2
作者 Himanshu Agrawal Himanshu Tanwar Nikhil Gupta 《Artificial Intelligence in Gastroenterology》 2025年第1期39-51,共13页
BACKGROUND Hepatobiliary surgery is complex and requires a thorough understanding of the liver’s anatomy,biliary system,and vasculature.Traditional imaging methods such as computed tomography(CT)and magnetic resonanc... BACKGROUND Hepatobiliary surgery is complex and requires a thorough understanding of the liver’s anatomy,biliary system,and vasculature.Traditional imaging methods such as computed tomography(CT)and magnetic resonance imaging(MRI),although helpful,fail to provide three-dimensional(3D)relationships of these structures,which are critical for planning and executing complicated surgeries.AIM To explore the use of 3D imaging and virtual surgical planning(VSP)technologies to improve surgical accuracy,reduce complications,and enhance patient recovery in hepatobiliary surgeries.METHODS A comprehensive review of studies published between 2017 and 2024 was conducted through PubMed,Scopus,Google Scholar,and Web of Science.Studies selected focused on 3D imaging and VSP applications in hepatobiliary surgery,assessing surgical precision,complications,and patient outcomes.Thirty studies,including randomized controlled trials,cohort studies,and case reports,were included in the final analysis.RESULTS Various 3D imaging modalities,including multidetector CT,MRI,and 3D rotational angiography,provide high-resolution views of the liver’s vascular and biliary anatomy.VSP allows surgeons to simulate complex surgeries,improving preoperative planning and reducing complications like bleeding and bile leaks.Several studies have demonstrated improved surgical precision,reduced complications,and faster recovery times when 3D imaging and VSP were used in complex surgeries.CONCLUSION 3D imaging and VSP technologies significantly enhance the accuracy and outcomes of hepatobiliary surgeries by providing individualized preoperative planning.While promising,further research,particularly randomized controlled trials,is needed to standardize protocols and evaluate long-term efficacy. 展开更多
关键词 three-dimensional imaging Virtual surgical planning Hepatobiliary surgery Surgical precision Preoperative planning
暂未订购
Polarimetric binocular three‑dimensional imaging in turbid water with multi‑feature self‑supervised learning
3
作者 Linghao Shen Liping Zhang +5 位作者 Pengfei Qi Xun Zhang Xiaobo Li Yizhao Huang Yongqiang Zhao Haofeng Hu 《PhotoniX》 2025年第1期394-414,共21页
Polarization imaging provides significant advantages in underwater environments.However,existing polarization underwater imaging methods primarily focus on leveraging polarization information to suppress the scatterin... Polarization imaging provides significant advantages in underwater environments.However,existing polarization underwater imaging methods primarily focus on leveraging polarization information to suppress the scattering effect to achieve the clear vision,while neglecting other valuable information contained in polarization images,such as the scene depth and the polarization characteristics of the objects.This paper proposes a self-supervised three-dimensional underwater imaging method based on a polarization binocular imager.In addition to improving image quality in turbid water based on polarization imaging,the proposed method merges features from both the enhanced binocular images recovered from polarization information and the feature-rich degree of polarization images into the self-supervised framework to estimate disparities of the scene,achieving high-quality reconstruction of underwater scene depth.We then design multiple self-supervised losses that effectively integrate depth information obtained from both binocular imaging and polarization imaging to guide the learning process.Meanwhile,the proposed method can recover the polarization information of the objects in turbid water,thus enhancing the perception of target properties such as the materials of the objects.Both the simulated experiment and the real-world experiments in the sea demonstrate the effectiveness and superiority of the proposed method. 展开更多
关键词 Underwater imaging Polarimetric binocular imaging Depth estimation Self-supervised learning
在线阅读 下载PDF
4D event imaging with a single neuromorphic camera
4
作者 Raviv Ilani Adrian Stern 《Advanced Photonics Nexus》 2026年第1期61-70,共10页
Neuromorphic cameras,or dynamic vision sensors,are bio-inspired event cameras that measure changes in the image brightness asynchronously and independently at the pixel level.Recently,they garnered increasing interest... Neuromorphic cameras,or dynamic vision sensors,are bio-inspired event cameras that measure changes in the image brightness asynchronously and independently at the pixel level.Recently,they garnered increasing interest due to their extremely high temporal resolution,wide dynamic range,low power consumption,and high pixel bandwidth.Despite their advantages,most existing three-dimensional (3D) event imaging solutions rely on multicamera configurations,which are costly,complex,and challenging to synchronize.In this study,we introduce a new framework for four-dimensional (4D) event imaging using a single static neuromorphic camera.We take advantage of the inherent sparsity of event data to combine optically encoded stereo channels into a single event camera.By utilizing optical channel multiplexing,we maintain sensor resolution while retaining the key advantages of event cameras. 展开更多
关键词 imaging and sensing bio-inspired image sensors neuromorphic imaging 3D imaging
在线阅读 下载PDF
Continuous imaging space in three-dimensional integral imaging 被引量:1
5
作者 张雷 杨勇 +3 位作者 王金刚 赵星 方志良 袁小聪 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第5期303-305,共3页
We report an integral imaging method with continuous imaging space. This method simultaneously reconstructs real and virtual images in the virtual mode, with a minimum gap that separates the entire imaging space into ... We report an integral imaging method with continuous imaging space. This method simultaneously reconstructs real and virtual images in the virtual mode, with a minimum gap that separates the entire imaging space into real and virtual space. Experimental results show that the gap is reduced to 45% of that in a conventional integral imaging system with the same parameters. 展开更多
关键词 three-dimensional integral imaging imaging space
原文传递
CROSS-TRACK THREE APERTURES MILLIMETER WAVE SAR SIDE-LOOKING THREE-DIMENSIONAL IMAGING 被引量:1
6
作者 Teng Xiumin Li Daojing +2 位作者 Li Liechen Liu Bo Pan Zhouhao 《Journal of Electronics(China)》 2012年第5期375-382,共8页
The airborne cross-track three apertures MilliMeter Wave (MMW) Synthetic Aperture Radar (SAR) side-looking three-Dimensional (3D) imaging is investigated in this paper. Three apertures are distributed along the cross-... The airborne cross-track three apertures MilliMeter Wave (MMW) Synthetic Aperture Radar (SAR) side-looking three-Dimensional (3D) imaging is investigated in this paper. Three apertures are distributed along the cross-track direction, and three virtual phase centers will be obtained through one-input and three-output. These three virtual phase centers form a sparse array which can be used to obtain the cross-track resolution. Because the cross-track array is short, the cross-track resolution is low. When the system works in side-looking mode, the cross-track resolution and height resolution will be coupling, and the low cross-track resolution will partly be transformed into the height uncertainty. The beam pattern of the real aperture is used as a weight to improve the Peak to SideLobe Ratio (PSLR) and Integrated SideLobe Ratio (ISLR) of the cross-track sparse array. In order to suppress the high cross-track sidelobes, a weighting preprocessing method is proposed. The 3D images of a point target and a simulation scene are achieved to verify the feasibility of the proposed method. And the imaging result of the real data obtained by the cross-track three-baseline MMW InSAR prototype is presented as a beneficial attempt. 展开更多
关键词 Synthetic Aperture Radar (SAR) Sparse array Side-looking imaging three-dimensional (3D) imaging
在线阅读 下载PDF
Promising four-dimensional flow magnetic resonance imaging technique for vascular flow analysis in children
7
作者 Jian-She Yang 《World Journal of Radiology》 2025年第4期47-49,共3页
Leesmidt et al present a comprehensive analysis of abdominal vascular flow in children using four-dimensional(4D)flow magnetic resonance imaging(MRI),aim to establish normal hemodynamic values for the abdominal viscer... Leesmidt et al present a comprehensive analysis of abdominal vascular flow in children using four-dimensional(4D)flow magnetic resonance imaging(MRI),aim to establish normal hemodynamic values for the abdominal visceral organs and to assess the feasibility of 4D flow MRI(4D-f-MRI)in this population.The researchers performed 4D-f-MRI on 9 pediatric patients with a history or suspi-cion of bowel pathology.Flow velocities were measured in the abdominal aorta and superior and inferior mesenteric arteries.The quality of the 4D-f-MRI images was evaluated,and the agreement between the measured flow velocities and those obtained from Duplex ultrasound was established.However,due to the specific limitations of this work,future studies should address the issues of small sample size and the specific age group design. 展开更多
关键词 Four-dimensional flow magnetic resonance imaging Hemodynamic values imaging DIAGNOSIS Vascular flow
暂未订购
Identification of the primary motor area by three-dimensional reconstruction of the corticospinal tract using diffusion tensor imaging
8
作者 Guojun Deng Luo Li +5 位作者 Guimei Chen Erming Zeng Xiangzuo Xiao Meihua Li Tao Hong Donghai Li 《Neural Regeneration Research》 SCIE CAS CSCD 2011年第14期1103-1107,共5页
Functional MRI (fMRI) is widely used as a non-invasive method for the evaluation of pre-operation motor function.However,patients with cortical function impairment,such as those with hemiparesis,can rarely achieve h... Functional MRI (fMRI) is widely used as a non-invasive method for the evaluation of pre-operation motor function.However,patients with cortical function impairment,such as those with hemiparesis,can rarely achieve hand clenching,a typical fMRI task for central sulcus identification,and the method is also of limited use in uncooperative children.Thus,it is important to develop a new method for identifying primary motor areas (PMA) in such individuals.This study used corticospinal tractography to identify the PMA in 20 patients with deep-seated brain tumor.Two regions of interest were set within the brainstem for corticospinal tract (CST) fiber tracking:one at the level of the pons and the other at the level of the cerebral peduncle.The CST fiber tracking results and fMRI activation signals were merged with three-dimensional anatomic MRI findings.The consistency of identifying the PMA by CST and fMRI was analyzed.fMRI activation signals were distributed mainly in the contralateral central sulcus around the omega-shaped hand knob.The CST consistently propagated from the pons and cerebral peduncle to the suspected PMA location.There was a good correlation between CST fiber tracking results and fMRI activation signals in terms of their abilities to identify the PMA.The differences between fMRI and CST fiber tracking findings may result from our functional task,which consisted only of hand movements.Our results indicate that diffusion tensor imaging is a useful brain mapping technique for identifying the PMA in paralyzed patients and uncooperative children. 展开更多
关键词 diffusion tensor imaging diffusion tensor tractography primary motor area functional magnetic resonance imaging TRACTOGRAPHY
在线阅读 下载PDF
Transforming pediatric imaging:The role of four-dimensional flow magnetic resonance imaging in quantifying mesenteric blood flow
9
作者 Arvind Mukundan Devansh Gupta +1 位作者 Riya Karmakar Hsiang-Chen Wang 《World Journal of Radiology》 2025年第6期174-178,共5页
The article"Assessment of superior mesenteric vascular flow quantitation in children using four-dimensional flow magnetic resonance imaging"suggests to use of four-dimensional(4D)flow magnetic resonance imag... The article"Assessment of superior mesenteric vascular flow quantitation in children using four-dimensional flow magnetic resonance imaging"suggests to use of four-dimensional(4D)flow magnetic resonance imaging(MRI)which is also to measure the blood flow in the superior mesenteric vein(SMV)in pediatric patients over the traditional method.The study focuses on assessing the potential of SMV and superior mesenteric artery(SMA)flow quantification in children utilizing 4D flow MRI.It included 9 pediatric patients aged 18 years and below where 5 were male and 4 were female patients,on whom magnetic resonance enterorrhaphy(MRE)with 4D flow MRI protocol was used.Statistical analysis was performed using MedCalc.Measurements of SMV and SMA between two readers were calculated using Bland-Altman analysis.The results stated that six patients showed no MRE evidence of active inflammatory bowel disease,two patients showed unmarkable bowel appearance on MRI and one patient showed normal MRE without endoscopy performed at the same timeframe.The study utilized available 4D flow MRI sequences in this study aiming to show the feasibility of 4D flow quantitation of SMA and SMV flow in pediatric patients.The study also discovered good agreement for both peak velocity and peak speed measurements of SMA and SMV. 展开更多
关键词 Pediatric radiology Four-dimensional flow magnetic resonance imaging Mesenteric vasculature Bowel disease HEMODYNAMICS Superior mesenteric artery Superior mesenteric vein Noninvasive imaging Feasibility study Socioeconomic impact
暂未订购
Optimized Three-Dimensional Cardiovascular Magnetic Resonance Whole Heart Imaging Utilizing Non-Selective Excitation and Compressed Sensing in Children and Adults with Congenital Heart Disease
10
作者 Ingo Paetsch Roman Gebauer +7 位作者 Christian Paech Frank-Thomas Riede Sabrina Oebel Andreas Bollmann Christian Stehning Jouke Smink Ingo Daehnert Cosima Jahnke 《Congenital Heart Disease》 SCIE 2023年第3期279-294,共16页
Background:In congenital heart disease(CHD)patients,detailed three-dimensional anatomy depiction plays a pivotal role for diagnosis and therapeutical decision making.Hence,the present study investigated the applicabil... Background:In congenital heart disease(CHD)patients,detailed three-dimensional anatomy depiction plays a pivotal role for diagnosis and therapeutical decision making.Hence,the present study investigated the applicability of an advanced cardiovascular magnetic resonance(CMR)whole heart imaging approach utilizing nonselective excitation and compressed sensing for anatomical assessment and interventional guidance of CHD patients in comparison to conventional dynamic CMR angiography.Methods:86 consecutive pediatric patients and adults with congenital heart disease(age,1 to 74 years;mean,35 years)underwent CMR imaging including a freebreathing,ECG-triggered 3D nonselective SSFP whole heart acquisition using compressed SENSE(nsWHcs).Anatomical assessability and signal intensity ratio(SIR)measurements were compared with conventional dynamic 3D-/4D-MR angiography.Results:The most frequent diagnoses were partial anomalous pulmonary venous drainage(17/86,20%),transposition of the great arteries(15/86,17%),tetralogy of Fallot(12/86,14%),and a single ventricle(7/86,8%).Image quality of nsWHcs was rated as excellent/good in 98%of patients.nsWHcs resulted in a reliable depiction of all large thoracic vessels(anatomic assessability,99%–100%)and the proximal segments of coronary arteries and coronary sinus(>90%).nsWHcs achieved a homogenously distributed SIR in all cardiac cavities and thoracic vessels without a significant difference between pulmonary and systemic circulation(10.9±3.5 and 10.6±3.4;p=0.15),while 3D angiography showed significantly increased SIR for targeted vs.non-targeted circulation(PA-angiography,15.2±8.1 vs.5.8±3.6,p<0.001;PV-angiography,7.0±3.9 vs.17.3±6.8,p<0.001).Conclusions:The proposed nsWHcs imaging approach provided a consistently high image quality and a homogeneous signal intensity distribution within the pulmonary and systemic circulation in pediatric patients and adults with a wide spectrum of congenital heart diseases.nsWHcs enabled detailed anatomical assessment and three-dimensional reconstruction of all cardiac cavities and large thoracic vessels and can be regarded particularly useful for preprocedural planning and interventional guidance in CHD patients. 展开更多
关键词 Cardiovascular magnetic resonance imaging congenital heart disease whole heart imaging nonselective SSFP compressed SENSE MR angiography
暂未订购
Imaging Findings of Sarcomatoid Carcinoma of the Ureter:A Case Report
11
作者 Wenyu Cai Xiaofen Ma 《Proceedings of Anticancer Research》 2026年第1期94-100,共7页
Background:Sarcomatoid carcinoma of the ureter(SCU)is a highly aggressive and relatively uncommon malignant tumor of the urinary tract.Its frequency is quite low,and its prognosis is very bad when compared to other ca... Background:Sarcomatoid carcinoma of the ureter(SCU)is a highly aggressive and relatively uncommon malignant tumor of the urinary tract.Its frequency is quite low,and its prognosis is very bad when compared to other cancers of the urinary system.SCU clinical reports are still hard to come by.MRI and PEI/CT imaging of ureteral sarcomatoid cancer is presented in this case to promote diagnostic awareness and comprehension of the imaging characteristics of this uncommon illness.Method:The patient had ureteral sarcomatoid cancer,which was verified by pathological investigation after ureteroscopic biopsy.The patient’s clinical information,imaging results,surgical outcomes,and pathological findings were gathered.A retrospective study was carried out in combinationwith pertinent national and international literature.Results:An 84-year-old female patient was admitted for“left flank discomfort lasting over one month.”MRI revealed an irregular soft tissue mass in the middle-lower segment of the left ureter.T2-weighted imaging showed an unevenly slightly hyperintense signal.Diffusion-weighted imaging demonstrated restricted diffusion.Contrastenhanced imaging exhibited heterogeneous enhancement.PET/CT demonstrated significantly increased fluorodeoxyglucose metabolism in the mass with secondary left upper urinary tract obstruction.Concurrent findings included a solitary metastatic lesion in hepatic segment S6 and multiple lymph node metastases along the left common iliac and external iliac arteries.Preoperative diagnosis suggested a malignant tumor of the ureter.The patient underwent left nephroureteroscopy with biopsy,and the postoperative pathological diagnosis was ureteral sarcomatoid carcinoma.Conclusion:Ureteral sarcomatoid carcinoma is a rare,highly malignant,and aggressive tumor with nonspecific imaging features,typically presenting as an invasively growing mass.Diagnosis relies on postoperative pathology and immunohistochemical examination.MRI and PET/CT scans are valuable for preoperative localization and characterization,tumor staging,treatment planning,and postoperative follow-up.The prognosis is extremely negative.The main treatment option is radical surgery,although constant monitoring is necessary since early recurrence and metastases are frequent after surgery. 展开更多
关键词 URETER Sarcomatoid carcinoma Magnetic resonance imaging Positron emission tomography imaging diagnosis
暂未订购
In vivo second near-infrared fluorescence and ratiometric photoacoustic dual-modality imaging of glutathione
12
作者 Yu Zhang Shan Lei +7 位作者 Yuantao Pan Chao Zhao Qiang Liu Yumeng Wu Yurong Liu Meng Li Peng Huang Jing Lin 《Chinese Chemical Letters》 2026年第2期303-307,共5页
The level of glutathione(GSH)is significantly associated with numerous pathological processes,thus,real-time detection of the GSH level is of significance for early diagnosis of GSH-related diseases.Herein,we develope... The level of glutathione(GSH)is significantly associated with numerous pathological processes,thus,real-time detection of the GSH level is of significance for early diagnosis of GSH-related diseases.Herein,we developed in vivo second near-infrared(NIR-II)window fluorescence(FL)and ratiometric photoacoustic(RPA)dual-modality imaging of GSH using a GSH-activatable probe(LET-14).LET-14 was synthesized based on a rhodamine hybrid xanthene skeleton with a FL shielding 2,4-dinitrobenzene sulfonyl group that can be specifically cleaved by GSH,thus resulting in a markedly bathochromic-shift absorption,a 6.5-fold increase in NIR-II FL intensity(FL_(920))and a 13-fold increase in RPA signal(PA_(880)/PA_(705))in vitro.Intriguingly,LET-14 exhibits good selectivity and sensitivity for NIR-II FL and RPA dual-modality imaging of GSH in 4T1 tumor-bearing mouse model.Our findings develop an in vivo detection tool of GSH,which has great potential in the field of cancer diagnosis. 展开更多
关键词 GLUTATHIONE In vivo Second near-infrared dye Fluorescence imaging Ratiometric photoacoustic imaging
原文传递
The application of multi-combinatorial approach in sensitivity improvement of lipid photoacoustic imaging
13
作者 Yi Tan Dongjian Wu +4 位作者 Xiatian Wang Chengbo Liu Mingjian Sun Xiaojing Gong Zhihua Xie 《Journal of Innovative Optical Health Sciences》 2026年第1期96-109,共14页
The photoacoustic imaging of lipid is intrinsically constrained by the feeble nature of endogenous lipid signals,posing a persistent sensitivity challenge that demands innovative solutions.Although adopting high-effic... The photoacoustic imaging of lipid is intrinsically constrained by the feeble nature of endogenous lipid signals,posing a persistent sensitivity challenge that demands innovative solutions.Although adopting high-efficiency excitation and detection elements may improve the imaging sensitivity to a certain extent,the application of the elements is inevitably subject to various limitations in practical applications,particularly during in vivo imaging and endoscopic imaging.In this study,we propose a multi-combinatorial approach to enhance the sensitivity of lipid photoacoustic imaging.The approach involves wavelet transform processing of one-dimensional A-line signals,gradient-based denoising of two-dimensional B-scan images,and finally,threedimensional spatial weighted averaging of the data processed by the previous two steps.This method not only significantly improves the signal-to-noise ratio(SNR)in distinguished feature regions of the image by around 10 dB,but also efficiently extracts weak signals with no distinct features in the original image.After processing with this method,the images acquired under single scanning were compared with those obtained under multiple scanning.The results showed highly consistent image features,with the structural similarity index increasing from 0.2 to 0.8,confirming the accuracy and reliability of the multi-combinatorial approach. 展开更多
关键词 Multi-combinatorial approach extraction of weak signals imaging sensitivity photoacoustic lipid imaging
原文传递
Research on imaging detection technology for 10–100 keV medium-energy electrons
14
作者 JiaChen Sun YuGuang Ye +3 位作者 Hong Zou JiaLi Chen TianHao Li WeiHong Shi 《Earth and Planetary Physics》 2026年第2期337-348,共12页
Electrons in the energy range of 10–100 keV are important energetic particle components in the magnetosphere,and they play a key role in many physical processes in the magnetosphere.However,many scientific questions ... Electrons in the energy range of 10–100 keV are important energetic particle components in the magnetosphere,and they play a key role in many physical processes in the magnetosphere.However,many scientific questions about these processes are still unanswered.High spatiotemporal and energy-resolution imaging detection of 10–100 keV electrons is of great significance for solving these scientific problems.The traditional space particle detection technology cannot effectively detect the medium-energy electrons in this energy range.In this project,we propose combining low-noise particle detection technology with pinhole imaging technology to achieve high-resolution imaging detection of 10–100 keV medium-energy electrons in the magnetosphere,and at the same time achieve miniaturization(≤3.2 kg and size of 150×150×170 mm)and low power consumption(≤5 W)of the instrument,which can be used for space physics research and space weather applications in the future. 展开更多
关键词 10-100 keV medium-energy electrons quasi-three-dimensional imaging detection imaging electron spectrometer continuous spectrum
在线阅读 下载PDF
Effect of measurement reduction on synthetic aperture x-ray ghost imaging
15
作者 Haipeng Zhang Jie Tang +4 位作者 Nixi Zhao Changzhe Zhao Jianwen Wu Zhongliang Li Tiqiao Xiao 《Chinese Physics B》 2026年第1期457-465,共9页
The unique advantage of x-ray ghost imaging(XGI)is its potential in low dose radiology.One of the practical ways to reduce the radiation exposure is to reduce the measurements while remaining sufficient image quality.... The unique advantage of x-ray ghost imaging(XGI)is its potential in low dose radiology.One of the practical ways to reduce the radiation exposure is to reduce the measurements while remaining sufficient image quality.Synthetic aperture x-ray ghost imaging(SAXGI)is invented to achieve megapixel XGI with limited measurements,which is expected to implement XGI simultaneously with large field of view and low radiation exposure.In this paper,we experimentally investigate the effect of measurements reduction on the spatial resolution and image quality of SAXGI with standard sample and biomedical specimen.The results with a resolution chart demonstrated that at 360 measurements,SAXGI successfully retrieved the sample image of 1960×1960 pixels with spatial resolution of 4μm.With measurement reduction,the spatial resolution deteriorates but the sparser structures are still discernable.Even with measurements reduced to 10,a spatial resolution of 10μm can still be achieved by SAXGI.A biomedical sample of a fish specimen is employed to evaluate the method and the fish image of 2000×1000 pixels with an SSIM of 0.962 is reconstructed by SAXGI with 770measurements,corresponding to an accumulative exposure reduction of more than 2 times.With the measurements reduced to 10 which corresponds to 1/160 of the accumulative radiation exposure for conventional radiology,bulky structure like the fish skeleton can still be definitely discerned and the SSIM for the reconstructed image still retained 0.9179.Results of this paper demonstrate that measurements reduction is practicable for the radiation exposure reduction of the sample,which implicates that SAXGI with limited measurements is an efficient solution for low dose radiology. 展开更多
关键词 x-ray ghost imaging synthetic aperture x-ray imaging low dose radiology compressed sensing algorithm
原文传递
Three-dimensional imaging identified the accessory bile duct in a patient with cholangiocarcinoma 被引量:7
16
作者 Ryoichi Miyamoto Yukio Oshiro +4 位作者 Shinji Hashimoto Keisuke Kohno Kiyoshi Fukunaga Tatsuya Oda Nobuhiro Ohkohchi 《World Journal of Gastroenterology》 SCIE CAS 2014年第32期11451-11455,共5页
The development of diagnostic imaging technology, such as multidetector computed tomography(MDCT) and magnetic resonance cholangiopancreatography(MRCP), has made it possible to obtain detailed images of the bile duct.... The development of diagnostic imaging technology, such as multidetector computed tomography(MDCT) and magnetic resonance cholangiopancreatography(MRCP), has made it possible to obtain detailed images of the bile duct. Recent reports have indicated that a 3-dimensional(3D) reconstructed imaging system would be useful for understanding the liver anatomy before surgery. We have investigated a novel method that fuses MDCT and MRCP images. This novel system easily made it possible to detect the anatomical relationship between the vessels and bile duct in the portal hepatis. In this report, we describe a very rare case of extrahepatic cholangiocarcinoma associated with an accessory bile duct from the caudate lobe connecting with the intrapancreatic bile duct. We were unable to preoperatively detect this accessory bile duct using MDCT and MRCP. However, prior to the second operation, we were able to clearly visualise the injured accessory bile duct using our novel 3D imaging modality. In thisreport, we suggest that this imaging technique can be considered a novel and useful modality for understanding the anatomy of the portal hepatis, including the hilar bile duct. 展开更多
关键词 3-dimensional imaging Hepatobiliary and pancreatic surgery Accessory bile duct Caudate lobe bile duct CHOLANGIOCARCINOMA
暂未订购
Application of Three-Dimensional Magnetic Resonance Imaging in the Diagnosis of Perianal Abscess 被引量:5
17
作者 Fang Zhang Shan Xiong +1 位作者 Sibin Liu Peng Xia 《Health》 2019年第5期535-545,共11页
Perianal abscess is a common disease in anorectal surgery. If the diagnosis is not clear and the cure is thoroughly cleared, the recurrence and spread of anal fistula will cause life-long pain. Objective: To investiga... Perianal abscess is a common disease in anorectal surgery. If the diagnosis is not clear and the cure is thoroughly cleared, the recurrence and spread of anal fistula will cause life-long pain. Objective: To investigate the application of 3.0T MRI 3D CUBE T2WI lipid suppression sequence in the diagnosis of perianal abscess. Methods: Thirty-six patients with perianal abscess confirmed by operation were examined with 2D T2WI and 3D CUBE T2WI lipid suppression sequences before operation. Two imaging techniques were evaluated to show the types of perianal abscess, the number of abscesses, the number of internal orifices of abscess, and the number of fistula branches with anal fistula in abscess. Results: Among 36 cases of perianal abscess, there were 5 cases of anal subcutaneous abscess, 12 cases of ischiorectal space abscess (8 cases complicated with anal fistula), 6 cases of posterior anal space abscess, 5 cases of anal sphincter abscess (3 cases complicated with anal fistula), 2 cases of high intermuscular abscess, 2 cases of rectal submucosal abscess, 3 cases of complex abscess (3 cases complicated with anal fistula), 1 case of misdiagnosis, 2D T2WI lipid suppression sequence and 3D CUBE T2WI suppression. The accuracy of lipid sequence abscess typing was 80.6% (29/36) and 88.9% (32/36), respectively, with no significant difference (P > 0.05). Thirty-six patients were surgically diagnosed as having 32 internal orifices, 68.8% (22/32) and 93.8% (30/32) of 2D T2WI and 3D CUBE T2WI lipid-suppressing sequences, respectively, with significant difference (P Conclusion: 3D CUBE T2WI lipid suppression sequence is superior to 2D T2WI lipid suppression sequence in the classification of perianal abscess, the number of internal orifices of abscess and the number of fistula branches of abscess complicated with anal fistula. It can also determine the number of internal orifices of abscess complicated with anal fistula, the number of fistula branches, the shape of primary and branch fistula and the relationship among pelvic floor muscle tissues. It can provide more accurate images for preoperative and intraoperative clinical surgery. 展开更多
关键词 Magnetic RESONANCE imaging three-dimensional imaging PERIANAL ABSCESS
暂未订购
Spinal cord imaging in preclinical research
18
作者 Lei Cao Ruiqing Ni 《Neural Regeneration Research》 2026年第6期2349-2350,共2页
The spinal cord links the brain and the peripheral nervous system and has important sensory and motor functions.Impairments in the spinal cord occur in different diseases,such as spinal cord injury,multiple sclerosis,... The spinal cord links the brain and the peripheral nervous system and has important sensory and motor functions.Impairments in the spinal cord occur in different diseases,such as spinal cord injury,multiple sclerosis,pain,motor neuron diseases,and neurodegenerative diseases.Imaging of the spinal cord has been challenging,partly due to its small size and deep anatomical location.Additionally,in an animal model,motion artifacts further influence the in vivo imaging quality of the spinal cord.Recent advances have pushed boundaries for in vivo imaging in living animals(even behaving animals). 展开更多
关键词 spinal cord injurymultiple vivo imaging spinal cordrecent neurodegenerative diseasesimaging spinal cord peripheral nervous system preclinicalresearch spinalcordinjury
暂未订购
Magnetic resonance imaging with three-dimensional fast imaging employing steady-state acquisition with phase-cycled and short T1 inversion recovery pulse sequence for evaluating brachial plexus injury 被引量:7
19
作者 Dianxiu Ning Meiyu Sun +11 位作者 Bo Sun Li Zhao Weisheng Zhang Lijun Wang Shaowu Wang Ailian Liu Jianlin Wu Zhijin Lang Di Ning Guanfu Liu Xiaochen Ji Xiufeng Wang 《Neural Regeneration Research》 SCIE CAS CSCD 2011年第14期1097-1102,共6页
There is a large amount of fat in the postganglionic segment of the brachial plexus nerve.The use of short T1 inversion recovery pulse sequence may improve signal strength of the brachial plexus postganglionic segment... There is a large amount of fat in the postganglionic segment of the brachial plexus nerve.The use of short T1 inversion recovery pulse sequence may improve signal strength of the brachial plexus postganglionic segment.The present study revealed that the combination of three-dimensional fast imaging employing steady-state acquisition with phase-cycled and short T1 inversion recovery pulse sequence clearly displayed the anatomical morphology and structure of the brachial plexus nerve,together with maximum intensity projection,volume rendering and other three-dimensional reconstruction techniques.Our results suggested that this method is also suitable for providing accurate assessment and diagnosis of the site,severity and scope of brachial plexus injury. 展开更多
关键词 brachial plexus i-njury magnetic resonance imaging pulse sequence reconstruction
在线阅读 下载PDF
Real-time Three-Dimensional Color Doppler Flow Imaging: An Improved Technique for Quantitative Analysis of Aortic Regurgitation 被引量:3
20
作者 吕清 刘夏天 +3 位作者 谢明星 王新房 王静 庄磊 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2006年第1期148-152,共5页
The recently introduced real-time three-dimensional color Doppler flow imaging (RT-3D CDFI) technique provides a quick and accurate calculation of regurgitant jet volume (RJV) and fraction. In order to evaluate RT... The recently introduced real-time three-dimensional color Doppler flow imaging (RT-3D CDFI) technique provides a quick and accurate calculation of regurgitant jet volume (RJV) and fraction. In order to evaluate RT-3D CDFI in the noninvasive assessment of aortic RJV and regurgitant jet fraction (RJF) in patients with isolated aortic regurgitation, real-time three-dimensional echocardiographic studies were performed on 23 patients with isolated aortic regurgitation to obtain LV end-diastolic volumes (LVEDV), end-systolic volumes (LVESV) and RJV, and then RJF could be calculated. The regurgitant volume (RV) and regurgitant fraction (RF) calculated by two-dimensional pulsed Doppler (2D-PD) method served as reference values. The results showed that aortic RJV measured by the RT-3D CDFI method showed a good correlation with the 2D-PD measurements (r= 0.93, Y=0.89X+ 3.9, SEE= 8.6 mL, P〈0.001 ); the mean (SD) difference between the two methods was - 1.5 (9.8) mL. % RJF estimated by the RT-3D CDFI method was also correlated well with the values obtained by the 2D-PD method (r=0.88, Y=0.71X+ 14.8, SEE= 6.4 %, P〈0. 001); the mean (SD) difference between the two methods was -1.2 (7.9) %. It was suggested that the newly developed RT-3D CDFI technique was feasible in the majority of patients. In patients with eccentric aortic regurgitation, this new modality provides additional information to that obtained from the two-dimensional examination, which overcomes the inherent limitations of two-dimensional echocardiography by depicting the full extent of the jet trajectory. In addition, the RT-3D CDFI method is quick and accurate in calculating RJV and RJF. 展开更多
关键词 real-time three-dimensional echocardiography color Doppler flow imaging aortic regurgitation
暂未订购
上一页 1 2 250 下一页 到第
使用帮助 返回顶部