Aflatoxin B1(AFB1)is a carcinogenic toxin naturally produced in most food crops that severely threaten human health,and effective methods are urgent to improve the detection accuracy.Herein an indirect competitive imm...Aflatoxin B1(AFB1)is a carcinogenic toxin naturally produced in most food crops that severely threaten human health,and effective methods are urgent to improve the detection accuracy.Herein an indirect competitive immunosorbent approach was elaborately developed based on high-affinity immunoglobulin G(IgG)coupled CuO-anchored Fe_(3)O_(4)nanozymes for precise and ultrasensitive detection of AFB_(1)in food crops including peanut,corn and wheat.The high-affinity nanozymes were fabricated by the assembly of inner core Fe_(3)O_(4)nanoparticles and mesoporous silica capping layer,Cu O further situated within large aperture of the coating layer via in-situ growth,and then conjugated with ligand rabbit anti-mouse Ig G,which can specifically bind with AFB_(1).The results showed the hybrid high-affinity nanozymes displayed enhanced peroxidasemimic activities and catalytic performances,achieving a linear range of 0.06-61.93(lg(ng/mL))and a detection limit of 0.0037 ng/mL,30 times better than that of the conventional enzyme-linked immunosorbent assay.The constructed nanozymes were successfully applied to the detection of AFB_(1)in food products with an average spiked recovery of 96.53%and relative standard deviations less than 2.8%.Therefore,the accurate hybrid nanozymes may serve for AFB_(1)detection in various foods in future.展开更多
Atrazine(AT,2-chloro-4-ethylamino-6-isopropyl-amino-s-triazine)has been detected in ground water in several areas of the United States for many years,as well as in China,wherein the growth rate of its gross
A total of 66 samples (from 27 cases with neuromyelitis optica, 26 cases with multiple sclerosis, aa 13 cases with optic neuritis) were tested for aquaporin-4 antibody by a cell-based immunofluorescence assay and an...A total of 66 samples (from 27 cases with neuromyelitis optica, 26 cases with multiple sclerosis, aa 13 cases with optic neuritis) were tested for aquaporin-4 antibody by a cell-based immunofluorescence assay and an enzyme-linked immunosorbent assay. The sensitivities and specificities of the two assays were similar. We further analyzed an additional 68 patients and 93 healthy controls using the enzyme-linked immunosorbent assay. A Kappa test showed good consistency between the two methods in terms of detection of anti-aquaporin-4 antibody in the se of neuromyelitis optica patients. No significant correlations were identified with onset age or disea duration, suggesting that aquaporin-4 antibody is a good marker for neuromyelitis optica. The enzyme-linked immunosorbent assay can be used for quantifying aquaporin-4 antibody concentrations and may be useful to dynamically monitor changes in the levels of aquaporin-4 antibody during disease duration.展开更多
A selective and sensitive competitive enzyme-linked immunosorbent assay(ELISA) method was developed and validated for the quantification of erlotinib in 50 mL of samples of human serum. Anti-erlotinib serum was obtain...A selective and sensitive competitive enzyme-linked immunosorbent assay(ELISA) method was developed and validated for the quantification of erlotinib in 50 mL of samples of human serum. Anti-erlotinib serum was obtained by immunizing mice with an antigen conjugated with bovine serum albumin and 3,4-bis(2-methoxyethoxy)benzoic acid using the N-succinimidyl ester method. Enzyme labeling of erlotinib with horseradish peroxidase was similarly performed using 3,4-bis(2-methoxyethoxy)benzoic acid. A simple competitive ELISA for erlotinib was developed using the principle of direct competition between erlotinib and the enzyme marker for anti-erlotinib antibody, which had been immobilized on the plastic surface of a microtiter plate. Serum erlotinib concentrations lower than 40 ng/mL were reproducibly measurable using the ELISA. This ELISA was specific to erlotinib and showed very slight cross-reactivity(6.7%) with a major metabolite, O-desmethyl erlotinib. Using this assay, drug levels were easily measured in the blood of mice after oral administration of erlotinib at a single dose of 30 mg/kg. ELISA should be used as a valuable tool for therapeutic drug monitoring and in pharmacokinetic studies of erlotinib.展开更多
Zika virus(ZIKV) causes rash, moderate fever, conjunctivitis, and arthralgia, and has serious connection with neurological complications;therefore, it is a major threat to public health. A rapid and supersensitive met...Zika virus(ZIKV) causes rash, moderate fever, conjunctivitis, and arthralgia, and has serious connection with neurological complications;therefore, it is a major threat to public health. A rapid and supersensitive method for detecting anti-ZIKV antibodies in humans and animals is thus urgently required. Here, we report an NS1-based luciferase immunosorbent assay(LISA), developed to detect ZIKV-specific IgG. Fusion proteins including a reporter Nano-luciferase(NLuc) and various fragments of ZIKV NS1 protein were expressed in 293 T cells. LISA was performed using the above cell lysates containing the expressed fusion proteins. Sample panels of humans and animals infected with ZIKV were examined for sensitivity of LISA, relative to those of ZIKV RT-PCR, commercial NS1-based ELISA, and micro-neutralization(MN) assays.Specificity and potential cross-reactivity were also evaluated using various convalescent serum samples derived from patients infected with dengue virus(DENV), Japanese encephalitis virus(JEV), and hepatitis C virus(HCV). Results indicated the optimal antigenic domain for anti-ZIKV IgG detection was located within 172–352 amino acids(aa) of ZIKV NS1 protein. NS1-based LISA performs better than commercial ELISA in anti-ZIKV Ig G detection. LISA was shown to be at least fourfold more sensitive than commercial ELISA, and could detect anti-ZIKV Ig G in various animal hosts without the need of species-specific labeled antibody. This novel assay is potentially useful for the rapid and sensitive detection of anti-ZIKV IgG in human and animal samples.展开更多
Afatinib is an oral tyrosine kinase inhibitor(TKI) approved for treating advanced non-small cell lung cancer. It is necessary to develop a simple quantification method for TKIs in order to facilitate therapeutic drug ...Afatinib is an oral tyrosine kinase inhibitor(TKI) approved for treating advanced non-small cell lung cancer. It is necessary to develop a simple quantification method for TKIs in order to facilitate therapeutic drug monitoring(TDM) in clinical settings. This study sought to develop a simple and sensitive competitive enzyme-linked immunosorbent assay(ELISA) to quantify afatinib in plasma for routine pharmacokinetic applications. An anti-afatinib antibody was obtained using(S)-N-4-(3-chloro-4-fluorophenyl)-7-(tetrahydrofuran-3-yloxy)-quinazoline-4,6-diamine(CTQD), which has the same substructure as afatinib, as a hapten. Enzyme labeling of afatinib with horseradish peroxidase was similarly performed using CTQD. A simple competitive ELISA for afatinib was developed based on the principle of direct competition between afatinib and the enzyme marker for the anti-afatinib antibody, which had been immobilized on the plastic surface of a microtiter plate. Plasma afatinib concentrations below the limit of quantification of 30 pg/mL were reproducibly measurable. Also, the values of plasma afatinib levels measured from 20 patients were comparable with those measured by high-performance liquid chromatography, and there was a strong correlation between the values determined by both methods(Y=0.976 X – 0.207, r=0.975). As indicated by its specificity and sensitivity, this newly developed ELISA for afatinib is an important tool for TDM and studies of the pharmacokinetics of afatinib.展开更多
The control and prevention of pasteurellosis in rabbits which makes the hosts unsuitable for experimental use raised the needs to improve and simplify the procedures of Enzyme-Linked Immunosorbent Assay (ELISA) for de...The control and prevention of pasteurellosis in rabbits which makes the hosts unsuitable for experimental use raised the needs to improve and simplify the procedures of Enzyme-Linked Immunosorbent Assay (ELISA) for detect of antibody against P.multocida. A comparison on the sensitivity and specificity of bacterial culture of antemortem and postmortem samples, complement fixation test and enzyme-linked immunosorbent assay of 11 apparently healthy adult rabbits was conducted. The incidence rates showed 45.45%,54.54% and 72.73% respectively. The sensitivity for the three methods were 0.63, 0.67,and 1.00,and specificity for them were 1.00, 0.67 and 1.00 respectively. Somatic serotypes of isolates of P.multocida from rabbits of three groups (rabbits of group 2 were with clinic signs, those of groups 1 and 3 were apparently healthy) revealed no remarkable differences,and the predominant types were type 3 and type 3, 4. This was somewhat different from the reports derived from other states. As the antigen of different serotype used in ELISA may have different sensitivity and specificity, which is affected also by different preparation method, a type non-specific antigen should be selected to meet such request. The trial of accomplishment of ELISA without positive and negative controls was presented for discussion.展开更多
Anti-bungarotoxin anti-serum,which has the internal image of nicotinicacetylcholine receptor,was used as a tool to measure anti-idiotypic antibodies toantibodies to Iigand of nicotinic acctylcholine receptor in scra f...Anti-bungarotoxin anti-serum,which has the internal image of nicotinicacetylcholine receptor,was used as a tool to measure anti-idiotypic antibodies toantibodies to Iigand of nicotinic acctylcholine receptor in scra from 81 patients withmyasthenia gravis.Enzyme-linked immunosorbcnt assay was adopted.Thc positive ratewas 46.9%(38/81).The specific cross inhibitory test with nicotinic acetylcholinereceptor was positive.Anti-idiotype antibodies to antibodies to ligand of nicotinicacetylcholine receptor in sera of different types of myasthenia gravis patients classified ac-cording to modified Osserman’s standard and myasthenia gravis patients with or withoutthymoma were comparcd in this study and the role of anti-idiotype antibodies toantibodies to Iigand of nicotinic acctylcholinc receptor in the immunity of myasthcniagravis and the possibility of thcrapeutic use of anti-idiotype antibodies arc discussed.展开更多
The simple rapid and sensitive enzyme-linked immunosorbent assay (ELISA) methods, di-rect and indirect ELISA, for quantitation of ochratoxin A in cereal had been developed by theutilization of monoclonal antibody on i...The simple rapid and sensitive enzyme-linked immunosorbent assay (ELISA) methods, di-rect and indirect ELISA, for quantitation of ochratoxin A in cereal had been developed by theutilization of monoclonal antibody on immunomicroplate. Direct FLIAS was found to be less timeconsuming than indirect ELISA. For direct FLISA, recovery of 1 -500 ppb OA added to wheat was78.9-100.0% and rice was 88.9- 120.0%. For indirect EI.IAS, recovery of 1-500 ppb OA addedto wheat was 79.0- 110.0% and rice was 82.0 120.0%. The minimal detection level for OA was Ippb. Analyses of 31 samples that caused humanintoxicant for OA showed that the ELISA resultsagreed wtll with those obtained by thin-layer chromatogrdphy.展开更多
GST-π was purified from human placenta and its antiserum was raised in rabbits. The antibody IgC was purified and degraded into Fab' fragment which was conjugated with horseradish peroxidase (HRP) using N-succini...GST-π was purified from human placenta and its antiserum was raised in rabbits. The antibody IgC was purified and degraded into Fab' fragment which was conjugated with horseradish peroxidase (HRP) using N-succinimidyl-4-(N-maleimido-methyl) cyclo-hexane-1-carboxylate (SMCC) as crosslinking reagent to produce Fab'-HRP conjugate. A sandwich ELISA was established for the microquantitative determination of GST-π. The sensitivity was 11 pg/tube, which was far more sensitive than the radioimmunoassay so far reported. Using this method, the serum GST-π of 41 cases normal adult was found to be 1.06±0.94 ng/ml. The upper limit of the normal value was 2.6 ng/ml. In 30 cases of primary hepatocarcinoma, the level of serum GST-π was 24.4± 17.4 ng/ml, which was 23 times higher than the normal average value (P<0.01). The positive rate was 90%. In contrast, serum GST-π in 25 cases of chronic hepatitis was determined to be 1.74±1.16 ng/ml, which was not significantly different from the normal value (P>0.05). The pseudo-positive rate was 12.0%.展开更多
Mycoplasma mycoides subsp mycoides SC (MmmSC) is the etiological agent of contagious bovine pleuropneumonia (CBPP). The lipoprotein LppQ encoded by lppQ gene is specific to MmmSC and is found in the type strain an...Mycoplasma mycoides subsp mycoides SC (MmmSC) is the etiological agent of contagious bovine pleuropneumonia (CBPP). The lipoprotein LppQ encoded by lppQ gene is specific to MmmSC and is found in the type strain and in field strains isolated in Europe, Africa, and Australia, as well as in vaccine strains. No serological cross-reactions were observed with the related mycoplasmas of the Mycoplasma mycoides cluster. The N-terminal domain of the mature lipoprotein LppQ is hydrophilic, and it induces a strong, specific, early, and persistent immune response in naturally and experimentally infected animals. Mycoplasma-specific TGA (Trp) codons are utilized as stop codons in most other organisms. The lppQ N-terminal fragment from MmmSC HVRI X strain, the Chinese strain for CF antigen production, was mutated with one-step overlapping extension PCR. Sequence analysis confirmed the successful mutation from A to G in codon 198 in the lppQ gene. The fragment containing the mutation site was subcloned into the pET32a expression vector. The recombinant protein with molecular weight of 42 kDa was purified using the Ni-NTA His.Bind purification kit, with a purity of up to 95%. Western blot indicated that the standard positive serum of CBPP could react with the recombinant protein. The purified protein was diluted to 0.35 μg mL^-1, and coated to microtiter enzyme-linked immunosorbent assay (ELISA) plates. Indirect ELISA reaction conditions were optimized. The value of P/N was determined to be 4.8 (0.934/0.193), the sensitivity to be 95.8% (46/48), and the specificity to be 98.9% (161/163). 3 817 cattle serum samples from three different provinces were detected by the indirect ELISA and CFT. The Kappa value is 0.63, which is middle or high agreement between the two methods.展开更多
Enzyme-linked immunosorbent assay (ELISA) is the most widely used method for measuring a single cytokine. Recent developments in cytokine quantification such as multiple arrays measure multiple cytokines simultaneousl...Enzyme-linked immunosorbent assay (ELISA) is the most widely used method for measuring a single cytokine. Recent developments in cytokine quantification such as multiple arrays measure multiple cytokines simultaneously. Although good correlations between ELISA and multiplex methods have been observed, side by side comparisons are limited. In the present study we hypothesized that ELISA and Luminex techniques are comparable in detecting cytokines in culture medium when pulmonary artery smooth muscle cells (PASMC) are exposed to stress. Primary human PASMC were cultured in modular chambers and exposed to 21% FiO2 and peak inspiratory and positive end expiratory pressure of 24 and 8 cmH2O respectively, and 95% FiO2. At 24 hours, culture medium was collected and assayed for interleukin-6 (IL-6) and IL-8 by quantitative ELISA and by Human Cytokine 25-Plex Panel using a Luminex 200 analyzer. A comparative analysis of agreement between our ELISA and Luminex data was detailed for control and stress conditions using the Bland-Altman plot analysis. Each assay resulted in comparable increased (p < 0.001) levels of IL-6 and IL-8 as compared to control in response to oxidative and biophysical stress. The Bland-Altman analysis demonstrated that 95% of the differences between ELISA and Luminex values were within ±1.96 SD from the mean difference indicated by the 95% limits of agreement for the measurements of IL-6 and IL-8. There was no systematic bias as a function of inflammation level. We conclude that in this cell culture model, ELISA and Luminex are comparable in detecting the levels of IL-6 and IL-8 in the culture medium. If measurements of multiple cytokines are demanded and the amount of sample is limited, Luminex multi-analyte profiling technology is accurate and sensitive.展开更多
In thes paper the authors used the Horseradish peroxidase labelledstaphylococcal protein A(HRP—SPA)in ELISA,for the detection of Clo-norchis sinensis infection.Serum tests were made on 116 confirmed cases ofclonorchi...In thes paper the authors used the Horseradish peroxidase labelledstaphylococcal protein A(HRP—SPA)in ELISA,for the detection of Clo-norchis sinensis infection.Serum tests were made on 116 confirmed cases ofclonorchiasis,103(88.8%)of them showed positive,while only 6(4.4%)werepositive among 138 healthy people.Samples were collected on filter paperstrips,111(95.7%)cases were positive among 116 comfirmed cases tested,but only 2(1.5%)were positive out of 138 healthy persons.The resultswere similar to those obtained by sheep antihuman IgG.Animal experimentalso showed that the SPA—ELISA can be used for the diagnosis ofclonorchiasis.In an endemic area,stool egg positive rate was 8.8%(62/703).whenchecked with SPA—ELISA,the rate of conformity in both filter paperstrips and stool examinations was 90.3(56/62).Among 641 serum testsfrom individuals negative in stool examinations,only 35(5.5%)reactedpositively.The authors suggested—that SPA—ELISA with soluble Clo-norchis antigens could be used in a large scale seroepidemiological surveyin endemic areas.展开更多
A rapid enzyme-linked immunosorbent assay(ELiSa)system for the detection of fipronil was studied.artificial antigens were synthesized through the glutaraldehyde method,and monoclonal antibodies were obtained via immun...A rapid enzyme-linked immunosorbent assay(ELiSa)system for the detection of fipronil was studied.artificial antigens were synthesized through the glutaraldehyde method,and monoclonal antibodies were obtained via immunization and fusion techniques.the concentration of the coated antigen and antibody and the reaction time were determined,and the recovery rate was determined by an ELiSa detection system.the cross-reaction rate of the antibody against fipronil metabolites was lower than 21.46%.the response time of the selected ELiSa system was 30 min shorter than that of the competitive ELiSa system.the iC20 to iC80 of the standard curve ranged from 0.139 to 1.433μg/L.the recovery rate of fipronil spiked in eggs was 76.7%-93.7%.this study provides support for the rapid ELiSa of fipronil.展开更多
Methyl jasmonate (MeJA) and its free-acid form, jasmonic acid (JA) are naturally occurring plant growth regulators widely distributed in higher plants. In order to improve the sensitivity for the analysis of MeJA ...Methyl jasmonate (MeJA) and its free-acid form, jasmonic acid (JA) are naturally occurring plant growth regulators widely distributed in higher plants. In order to improve the sensitivity for the analysis of MeJA at low levels in small amounts of plant samples, a monoclonal antibody (MAb) (designated as MAb 3E5D7C4B6) against MeJA was derived from a JA- bovine serum albumin (BSA) conjugate as an immunogen. The antibody belongs to the IgG1 subclass with a κ type light chain and has a dissociation constant of approximately 6.07 ×10^-9 M. MAb3E5D7C4B6 is very specific to MeJA. It was used to develop a direct competitive enzyme-linked immunosorbent assay (dcELISA), conventional and simplified indirect competitive ELISAs (icELISA). JA was derivatized into MeJA for the ELISA analysis. The IC50 value and detection range for MeJA were, respectively, 34 and 4-257 nglmL by the conventional icELISA, 21 and 3-226 nglmL by the simplified icELISA and 5.0 and 0.7-97.0 nglmL by the dcELISA. The dcELISA was more sensitive than either the conventional or simplified icELISA. The assays were used to measure the content of jasmonates as MeJA in tobacco leaves under drought stress or inoculated with tobacco mosaic virus and tomato leaves inoculated with tomato mosaic virus or Lirioinyza sativae Blanchard as compared with the corresponding healthy leaves. The increased jasmonates content indicated its role in response to the drought stress and pathogens.展开更多
Diethylstilbestrol (DES) is a synthetic estrogen that has ever been used worldwide. Polyclonal antibodies (PAbs) were used in immunoassay for detection of DES residues in environmental and agricultural samples in ...Diethylstilbestrol (DES) is a synthetic estrogen that has ever been used worldwide. Polyclonal antibodies (PAbs) were used in immunoassay for detection of DES residues in environmental and agricultural samples in previous paper. In this paper, an indirect competitive enzyme-linked immunosorbent assay (icELISA) was developed based on monoclonal antibody (MAb) for the determination of diethylstilbestrol. Mono-o-carboxypropyldiethylstilbestrol (DES-CP) and mono-o-carboxymethyldiethylstilbestrol (DES-CME) were synthesized to be haptens. DES-CP was coupled to bovine serum albumin (BSA) to be an immunogen in BALB/c female mouse for MAb production. The MAb was characterized for specificity and affinity to DES in icELISA. Under the optimum condition, the icELISA showed an ICs0 of 9.8 ng/mL, the limit of detection (IC20) of 2.3 ng/mL and a working range of 2-42 ng/mL. Hexestrol and dienestrol exhibited cross-reactivity values were 44% and 27%, respectively. Cross-reactivity of natural estrogen 17β-estradiol was less than 0.1%. The influences of some factors such as salt concentration, pH and organic solvent concentration on the assay were evaluated. The concentrations of DES in the fortified water samples determined by the assay were correlated well with the fortification levels. The results were conf'm'ned with analysis by HPLC.展开更多
Cytokine monitoring has attracted great attention due to its significance in the diagnosis and treatment of many diseases,such as tumors,microbial infections,and immunological diseases.Enzyme-linked immunosorbent assa...Cytokine monitoring has attracted great attention due to its significance in the diagnosis and treatment of many diseases,such as tumors,microbial infections,and immunological diseases.Enzyme-linked immunosorbent assay(ELISA)is one of the most popular methods in cytokine detection,ascribing to the lavish signal amplification methods in the ELISA platform.In addition to classical enzymes,other signal amplifiers such as fluorescent probes,artificial nano-enzymes,and photothermal reagents have been applied to reduce the detection limit and produce more sensitive ELISA kits.Due to the accumulative effect of heat,photothermal reagents are promising materials in the signal amplification of ELISA.However,the lack of efficient photothermal generation material at an aggregate scale may delay the further development of this area.In this contribution,based on an efficient organic photothermal aggregate material,an enzyme-free photothermally amplified fluorescent immunosorbent assay system consisting of an assay microfluidic chip and detecting platform was developed.The photothermal nanoparticles with highly efficient photothermal conversion by harvesting energy via excited-state intramolecular motions and enlarging molar absorptivity were successfully prepared.The detection concentration at 50 pg/mL of interleukin-2 was achieved,realizing a signal improvement of detection limits by 20-fold compared to that of previously reported photothermal ELISA.The microscopic imaging integrated with plane sweeping technology provided high spatial resolution and precision,indicating the potential of achieving high throughput profiling at the microscale.Moreover,as an alternative excitation source,light-emitting diode not only provided a more affordable and miniaturized detection system but also revealed the great feasibility of intramolecular motion-induced photothermy nanoparticles for biological analyses.展开更多
Microcystins(MCs)are a group of closely related toxic cyclic heptapeptides produced by common cyanobacte-ria,which cause lots of accidents and threatens human health.In this paper,an indirect competitive enzyme-linked...Microcystins(MCs)are a group of closely related toxic cyclic heptapeptides produced by common cyanobacte-ria,which cause lots of accidents and threatens human health.In this paper,an indirect competitive enzyme-linked immu-nosorbent assay(ic-ELISA)was established and used to detect microcystin-LR(MC-LR)in drinking and surface waters.The concentration of coating antigen was 5 mg/mL,the dilution of monoclonal antibody MC10E7 was 1:3000,the dilution of enzyme tracer(goat anti-mouse IgG-peroxidase)was 1:3000,the standard concentration of MC-LR ranged from 0.001 mg/L to 30 mg/L,and o-phenylenediamine was used as substrate.The assay showed high relativity with high performance liquid chromatography(HPLC)with a correlation coefficient of more than 99%.The relative standard deviation was less than 10%,the detection limit was achieved down to 0.01 mg/L and up to 5.1 mg/L.The quantitative detection range was from 0.03 mg/L to 3 mg/L,and the antibody had high specificity for[4-arginine]microcystins.It performed well in spite of the influence of the real samples.展开更多
Background Severe acute respiratory syndrome coronavirus (SARS-CoV) is a newly emerging virus that gives rise to SARS patients with high rates of infectivity and fatality. To study the humoral immune responses to SARS...Background Severe acute respiratory syndrome coronavirus (SARS-CoV) is a newly emerging virus that gives rise to SARS patients with high rates of infectivity and fatality. To study the humoral immune responses to SARS-CoV, the authors evaluated IgG and IgM specific antibodies in patients’ sera.Methods Two methods, enzyme-linked immunosorbent assay (ELISA) and indirect immunofluorescent assay (IFA), were used to detect specific serum IgG and IgM against SARS-CoV in 98 SARS patients and 250 controls consisting of patients with pneumonia, health-care professionals and healthy subjects. The serum antibody profiles were investigated at different times over one and a half years in 18 of the SARS patients. Results The sensitivity and specificity of ELISA for detecting IgG against SARS-CoV were 100.0% and 97.2% and for IgM 89.8% and 97.6% respectively; the figures using IFA for IgG were 100.0% and 100.0% and for IgM 81.8% and 100.0% respectively. During the first seven days of the antibodies trace test, no IgG and IgM were detected, but on day 15, IgG response increased dramatically, reaching a peak on day 60, remaining high up to day 180 and decreasing gradually until day 540. On day 15, IgM was detected, rapidly reached a peak, then declined gradually until day 180 when IgM was undetectable. Conclusion The detection of antibodies against SARS virus is helpful in the clinical diagnosis of SARS.展开更多
The Middle East respiratory syndrome(MERS)is a lethal zoonosis caused by MERS coronavirus(MERS-CoV)and poses a significant threat to public health worldwide.Therefore,a rapid,sensitive,and specific serologic test for ...The Middle East respiratory syndrome(MERS)is a lethal zoonosis caused by MERS coronavirus(MERS-CoV)and poses a significant threat to public health worldwide.Therefore,a rapid,sensitive,and specific serologic test for detecting anti-MERS-CoV antibodies in both humans and animals is urgently needed for the successful management of this illness.Here,we evaluated various novel luciferase immunosorbent assays(LISA)based on nucleocapsid protein(NP)as well as fragments derived from spike protein(S)including subunit 1(S1),N terminal domain(NTD),receptorbinding domain(RBD)and subunit 2(S2)of S for the detection of MERS-CoV-specific IgG.Fusion proteins,including nanoluciferase(NLuc)and various fragments derived from the NP or S protein of MERS-CoV,were expressed in human embryonic kidney 293 T cells.LISAs that detected anti-MERS-CoV IgG were further developed using cell lysates expressing various fusion proteins.Panels of human or animal samples infected with MERS-CoV were used to analyze the sensitivity and specificity of various LISAs in reference to a MERS-CoV RT-PCR,commercial S1-based ELISA,and pseudovirus particle neutralization test(ppNT).Our results showed that the S1-,RBD-,and NP-LISAs were more sensitive than the NTD-and S2-LISAs for the detection of anti-MERS-CoV IgG.Furthermore,the S1-,RBD-,and NP-LISAs were more sensitive(by at least 16-fold)than the commercially available S1-ELISA.Moreover,the S1-,RBD-,and NPLISA specifically recognized anti-MERS-CoV IgG and did not cross-react with samples derived from other human CoV(OC43,229E,HKU1,NL63)-infected patients.More importantly,these LISAs proved their applicability and reliability for detecting anti-MERS-CoV IgG in samples from camels,monkeys,and mice,among which the RBD-LISA exhibited excellent performance.The results of this study suggest that the novel MERS-CoV RBD-and S1-LISAs are highly effective platforms for the rapid and sensitive detection of anti-MERS-CoV IgG in human and animal samples.These assays have the potential to be used as serologic tests for the management and control of MERS-CoV infection.展开更多
基金supported by the Scientific and Technological Project of Henan Province(232102321117)National Natural Science Foundation of China(82202198)+2 种基金the National Engineering Research Center of Wheat and Corn Further Processing of Henan University of Technology(NL2022010)Project of Basic Research Fund of Henan Provincial Institute of Medical and Pharmacological Sciences(2023BP0106)the Innovative Funds Plan of Henan University of Technology(2020ZKCJ23)。
文摘Aflatoxin B1(AFB1)is a carcinogenic toxin naturally produced in most food crops that severely threaten human health,and effective methods are urgent to improve the detection accuracy.Herein an indirect competitive immunosorbent approach was elaborately developed based on high-affinity immunoglobulin G(IgG)coupled CuO-anchored Fe_(3)O_(4)nanozymes for precise and ultrasensitive detection of AFB_(1)in food crops including peanut,corn and wheat.The high-affinity nanozymes were fabricated by the assembly of inner core Fe_(3)O_(4)nanoparticles and mesoporous silica capping layer,Cu O further situated within large aperture of the coating layer via in-situ growth,and then conjugated with ligand rabbit anti-mouse Ig G,which can specifically bind with AFB_(1).The results showed the hybrid high-affinity nanozymes displayed enhanced peroxidasemimic activities and catalytic performances,achieving a linear range of 0.06-61.93(lg(ng/mL))and a detection limit of 0.0037 ng/mL,30 times better than that of the conventional enzyme-linked immunosorbent assay.The constructed nanozymes were successfully applied to the detection of AFB_(1)in food products with an average spiked recovery of 96.53%and relative standard deviations less than 2.8%.Therefore,the accurate hybrid nanozymes may serve for AFB_(1)detection in various foods in future.
基金supported by the National Natural Science Foundation of China(No.81030052,20907074)National Science & Technology Supporting Program(2012BAJ25B03-02)Tianjin Science & Technology Program(11ZCKFSF01100)
文摘Atrazine(AT,2-chloro-4-ethylamino-6-isopropyl-amino-s-triazine)has been detected in ground water in several areas of the United States for many years,as well as in China,wherein the growth rate of its gross
基金the grants from the Ministry of Sciences and Technology of China, No. 2006AA02A408, 2008ZX09312-014
文摘A total of 66 samples (from 27 cases with neuromyelitis optica, 26 cases with multiple sclerosis, aa 13 cases with optic neuritis) were tested for aquaporin-4 antibody by a cell-based immunofluorescence assay and an enzyme-linked immunosorbent assay. The sensitivities and specificities of the two assays were similar. We further analyzed an additional 68 patients and 93 healthy controls using the enzyme-linked immunosorbent assay. A Kappa test showed good consistency between the two methods in terms of detection of anti-aquaporin-4 antibody in the se of neuromyelitis optica patients. No significant correlations were identified with onset age or disea duration, suggesting that aquaporin-4 antibody is a good marker for neuromyelitis optica. The enzyme-linked immunosorbent assay can be used for quantifying aquaporin-4 antibody concentrations and may be useful to dynamically monitor changes in the levels of aquaporin-4 antibody during disease duration.
文摘A selective and sensitive competitive enzyme-linked immunosorbent assay(ELISA) method was developed and validated for the quantification of erlotinib in 50 mL of samples of human serum. Anti-erlotinib serum was obtained by immunizing mice with an antigen conjugated with bovine serum albumin and 3,4-bis(2-methoxyethoxy)benzoic acid using the N-succinimidyl ester method. Enzyme labeling of erlotinib with horseradish peroxidase was similarly performed using 3,4-bis(2-methoxyethoxy)benzoic acid. A simple competitive ELISA for erlotinib was developed using the principle of direct competition between erlotinib and the enzyme marker for anti-erlotinib antibody, which had been immobilized on the plastic surface of a microtiter plate. Serum erlotinib concentrations lower than 40 ng/mL were reproducibly measurable using the ELISA. This ELISA was specific to erlotinib and showed very slight cross-reactivity(6.7%) with a major metabolite, O-desmethyl erlotinib. Using this assay, drug levels were easily measured in the blood of mice after oral administration of erlotinib at a single dose of 30 mg/kg. ELISA should be used as a valuable tool for therapeutic drug monitoring and in pharmacokinetic studies of erlotinib.
基金the National Key Research and Development Program of China(2016YFD0500301)the National Major Project for Control and Prevention of Infectious Disease in China(2018ZX10101002 and 2017YFC1200503)+1 种基金the Bureau of Science and Information Technology of Guangzhou Municipality,China(201604020011,201704020219)National Key R&D Program of China(2018ZX10732401).
文摘Zika virus(ZIKV) causes rash, moderate fever, conjunctivitis, and arthralgia, and has serious connection with neurological complications;therefore, it is a major threat to public health. A rapid and supersensitive method for detecting anti-ZIKV antibodies in humans and animals is thus urgently required. Here, we report an NS1-based luciferase immunosorbent assay(LISA), developed to detect ZIKV-specific IgG. Fusion proteins including a reporter Nano-luciferase(NLuc) and various fragments of ZIKV NS1 protein were expressed in 293 T cells. LISA was performed using the above cell lysates containing the expressed fusion proteins. Sample panels of humans and animals infected with ZIKV were examined for sensitivity of LISA, relative to those of ZIKV RT-PCR, commercial NS1-based ELISA, and micro-neutralization(MN) assays.Specificity and potential cross-reactivity were also evaluated using various convalescent serum samples derived from patients infected with dengue virus(DENV), Japanese encephalitis virus(JEV), and hepatitis C virus(HCV). Results indicated the optimal antigenic domain for anti-ZIKV IgG detection was located within 172–352 amino acids(aa) of ZIKV NS1 protein. NS1-based LISA performs better than commercial ELISA in anti-ZIKV Ig G detection. LISA was shown to be at least fourfold more sensitive than commercial ELISA, and could detect anti-ZIKV Ig G in various animal hosts without the need of species-specific labeled antibody. This novel assay is potentially useful for the rapid and sensitive detection of anti-ZIKV IgG in human and animal samples.
文摘Afatinib is an oral tyrosine kinase inhibitor(TKI) approved for treating advanced non-small cell lung cancer. It is necessary to develop a simple quantification method for TKIs in order to facilitate therapeutic drug monitoring(TDM) in clinical settings. This study sought to develop a simple and sensitive competitive enzyme-linked immunosorbent assay(ELISA) to quantify afatinib in plasma for routine pharmacokinetic applications. An anti-afatinib antibody was obtained using(S)-N-4-(3-chloro-4-fluorophenyl)-7-(tetrahydrofuran-3-yloxy)-quinazoline-4,6-diamine(CTQD), which has the same substructure as afatinib, as a hapten. Enzyme labeling of afatinib with horseradish peroxidase was similarly performed using CTQD. A simple competitive ELISA for afatinib was developed based on the principle of direct competition between afatinib and the enzyme marker for the anti-afatinib antibody, which had been immobilized on the plastic surface of a microtiter plate. Plasma afatinib concentrations below the limit of quantification of 30 pg/mL were reproducibly measurable. Also, the values of plasma afatinib levels measured from 20 patients were comparable with those measured by high-performance liquid chromatography, and there was a strong correlation between the values determined by both methods(Y=0.976 X – 0.207, r=0.975). As indicated by its specificity and sensitivity, this newly developed ELISA for afatinib is an important tool for TDM and studies of the pharmacokinetics of afatinib.
文摘The control and prevention of pasteurellosis in rabbits which makes the hosts unsuitable for experimental use raised the needs to improve and simplify the procedures of Enzyme-Linked Immunosorbent Assay (ELISA) for detect of antibody against P.multocida. A comparison on the sensitivity and specificity of bacterial culture of antemortem and postmortem samples, complement fixation test and enzyme-linked immunosorbent assay of 11 apparently healthy adult rabbits was conducted. The incidence rates showed 45.45%,54.54% and 72.73% respectively. The sensitivity for the three methods were 0.63, 0.67,and 1.00,and specificity for them were 1.00, 0.67 and 1.00 respectively. Somatic serotypes of isolates of P.multocida from rabbits of three groups (rabbits of group 2 were with clinic signs, those of groups 1 and 3 were apparently healthy) revealed no remarkable differences,and the predominant types were type 3 and type 3, 4. This was somewhat different from the reports derived from other states. As the antigen of different serotype used in ELISA may have different sensitivity and specificity, which is affected also by different preparation method, a type non-specific antigen should be selected to meet such request. The trial of accomplishment of ELISA without positive and negative controls was presented for discussion.
文摘Anti-bungarotoxin anti-serum,which has the internal image of nicotinicacetylcholine receptor,was used as a tool to measure anti-idiotypic antibodies toantibodies to Iigand of nicotinic acctylcholine receptor in scra from 81 patients withmyasthenia gravis.Enzyme-linked immunosorbcnt assay was adopted.Thc positive ratewas 46.9%(38/81).The specific cross inhibitory test with nicotinic acetylcholinereceptor was positive.Anti-idiotype antibodies to antibodies to ligand of nicotinicacetylcholine receptor in sera of different types of myasthenia gravis patients classified ac-cording to modified Osserman’s standard and myasthenia gravis patients with or withoutthymoma were comparcd in this study and the role of anti-idiotype antibodies toantibodies to Iigand of nicotinic acctylcholinc receptor in the immunity of myasthcniagravis and the possibility of thcrapeutic use of anti-idiotype antibodies arc discussed.
文摘The simple rapid and sensitive enzyme-linked immunosorbent assay (ELISA) methods, di-rect and indirect ELISA, for quantitation of ochratoxin A in cereal had been developed by theutilization of monoclonal antibody on immunomicroplate. Direct FLIAS was found to be less timeconsuming than indirect ELISA. For direct FLISA, recovery of 1 -500 ppb OA added to wheat was78.9-100.0% and rice was 88.9- 120.0%. For indirect EI.IAS, recovery of 1-500 ppb OA addedto wheat was 79.0- 110.0% and rice was 82.0 120.0%. The minimal detection level for OA was Ippb. Analyses of 31 samples that caused humanintoxicant for OA showed that the ELISA resultsagreed wtll with those obtained by thin-layer chromatogrdphy.
文摘GST-π was purified from human placenta and its antiserum was raised in rabbits. The antibody IgC was purified and degraded into Fab' fragment which was conjugated with horseradish peroxidase (HRP) using N-succinimidyl-4-(N-maleimido-methyl) cyclo-hexane-1-carboxylate (SMCC) as crosslinking reagent to produce Fab'-HRP conjugate. A sandwich ELISA was established for the microquantitative determination of GST-π. The sensitivity was 11 pg/tube, which was far more sensitive than the radioimmunoassay so far reported. Using this method, the serum GST-π of 41 cases normal adult was found to be 1.06±0.94 ng/ml. The upper limit of the normal value was 2.6 ng/ml. In 30 cases of primary hepatocarcinoma, the level of serum GST-π was 24.4± 17.4 ng/ml, which was 23 times higher than the normal average value (P<0.01). The positive rate was 90%. In contrast, serum GST-π in 25 cases of chronic hepatitis was determined to be 1.74±1.16 ng/ml, which was not significantly different from the normal value (P>0.05). The pseudo-positive rate was 12.0%.
文摘Mycoplasma mycoides subsp mycoides SC (MmmSC) is the etiological agent of contagious bovine pleuropneumonia (CBPP). The lipoprotein LppQ encoded by lppQ gene is specific to MmmSC and is found in the type strain and in field strains isolated in Europe, Africa, and Australia, as well as in vaccine strains. No serological cross-reactions were observed with the related mycoplasmas of the Mycoplasma mycoides cluster. The N-terminal domain of the mature lipoprotein LppQ is hydrophilic, and it induces a strong, specific, early, and persistent immune response in naturally and experimentally infected animals. Mycoplasma-specific TGA (Trp) codons are utilized as stop codons in most other organisms. The lppQ N-terminal fragment from MmmSC HVRI X strain, the Chinese strain for CF antigen production, was mutated with one-step overlapping extension PCR. Sequence analysis confirmed the successful mutation from A to G in codon 198 in the lppQ gene. The fragment containing the mutation site was subcloned into the pET32a expression vector. The recombinant protein with molecular weight of 42 kDa was purified using the Ni-NTA His.Bind purification kit, with a purity of up to 95%. Western blot indicated that the standard positive serum of CBPP could react with the recombinant protein. The purified protein was diluted to 0.35 μg mL^-1, and coated to microtiter enzyme-linked immunosorbent assay (ELISA) plates. Indirect ELISA reaction conditions were optimized. The value of P/N was determined to be 4.8 (0.934/0.193), the sensitivity to be 95.8% (46/48), and the specificity to be 98.9% (161/163). 3 817 cattle serum samples from three different provinces were detected by the indirect ELISA and CFT. The Kappa value is 0.63, which is middle or high agreement between the two methods.
文摘Enzyme-linked immunosorbent assay (ELISA) is the most widely used method for measuring a single cytokine. Recent developments in cytokine quantification such as multiple arrays measure multiple cytokines simultaneously. Although good correlations between ELISA and multiplex methods have been observed, side by side comparisons are limited. In the present study we hypothesized that ELISA and Luminex techniques are comparable in detecting cytokines in culture medium when pulmonary artery smooth muscle cells (PASMC) are exposed to stress. Primary human PASMC were cultured in modular chambers and exposed to 21% FiO2 and peak inspiratory and positive end expiratory pressure of 24 and 8 cmH2O respectively, and 95% FiO2. At 24 hours, culture medium was collected and assayed for interleukin-6 (IL-6) and IL-8 by quantitative ELISA and by Human Cytokine 25-Plex Panel using a Luminex 200 analyzer. A comparative analysis of agreement between our ELISA and Luminex data was detailed for control and stress conditions using the Bland-Altman plot analysis. Each assay resulted in comparable increased (p < 0.001) levels of IL-6 and IL-8 as compared to control in response to oxidative and biophysical stress. The Bland-Altman analysis demonstrated that 95% of the differences between ELISA and Luminex values were within ±1.96 SD from the mean difference indicated by the 95% limits of agreement for the measurements of IL-6 and IL-8. There was no systematic bias as a function of inflammation level. We conclude that in this cell culture model, ELISA and Luminex are comparable in detecting the levels of IL-6 and IL-8 in the culture medium. If measurements of multiple cytokines are demanded and the amount of sample is limited, Luminex multi-analyte profiling technology is accurate and sensitive.
文摘In thes paper the authors used the Horseradish peroxidase labelledstaphylococcal protein A(HRP—SPA)in ELISA,for the detection of Clo-norchis sinensis infection.Serum tests were made on 116 confirmed cases ofclonorchiasis,103(88.8%)of them showed positive,while only 6(4.4%)werepositive among 138 healthy people.Samples were collected on filter paperstrips,111(95.7%)cases were positive among 116 comfirmed cases tested,but only 2(1.5%)were positive out of 138 healthy persons.The resultswere similar to those obtained by sheep antihuman IgG.Animal experimentalso showed that the SPA—ELISA can be used for the diagnosis ofclonorchiasis.In an endemic area,stool egg positive rate was 8.8%(62/703).whenchecked with SPA—ELISA,the rate of conformity in both filter paperstrips and stool examinations was 90.3(56/62).Among 641 serum testsfrom individuals negative in stool examinations,only 35(5.5%)reactedpositively.The authors suggested—that SPA—ELISA with soluble Clo-norchis antigens could be used in a large scale seroepidemiological surveyin endemic areas.
文摘A rapid enzyme-linked immunosorbent assay(ELiSa)system for the detection of fipronil was studied.artificial antigens were synthesized through the glutaraldehyde method,and monoclonal antibodies were obtained via immunization and fusion techniques.the concentration of the coated antigen and antibody and the reaction time were determined,and the recovery rate was determined by an ELiSa detection system.the cross-reaction rate of the antibody against fipronil metabolites was lower than 21.46%.the response time of the selected ELiSa system was 30 min shorter than that of the competitive ELiSa system.the iC20 to iC80 of the standard curve ranged from 0.139 to 1.433μg/L.the recovery rate of fipronil spiked in eggs was 76.7%-93.7%.this study provides support for the rapid ELiSa of fipronil.
文摘Methyl jasmonate (MeJA) and its free-acid form, jasmonic acid (JA) are naturally occurring plant growth regulators widely distributed in higher plants. In order to improve the sensitivity for the analysis of MeJA at low levels in small amounts of plant samples, a monoclonal antibody (MAb) (designated as MAb 3E5D7C4B6) against MeJA was derived from a JA- bovine serum albumin (BSA) conjugate as an immunogen. The antibody belongs to the IgG1 subclass with a κ type light chain and has a dissociation constant of approximately 6.07 ×10^-9 M. MAb3E5D7C4B6 is very specific to MeJA. It was used to develop a direct competitive enzyme-linked immunosorbent assay (dcELISA), conventional and simplified indirect competitive ELISAs (icELISA). JA was derivatized into MeJA for the ELISA analysis. The IC50 value and detection range for MeJA were, respectively, 34 and 4-257 nglmL by the conventional icELISA, 21 and 3-226 nglmL by the simplified icELISA and 5.0 and 0.7-97.0 nglmL by the dcELISA. The dcELISA was more sensitive than either the conventional or simplified icELISA. The assays were used to measure the content of jasmonates as MeJA in tobacco leaves under drought stress or inoculated with tobacco mosaic virus and tomato leaves inoculated with tomato mosaic virus or Lirioinyza sativae Blanchard as compared with the corresponding healthy leaves. The increased jasmonates content indicated its role in response to the drought stress and pathogens.
文摘Diethylstilbestrol (DES) is a synthetic estrogen that has ever been used worldwide. Polyclonal antibodies (PAbs) were used in immunoassay for detection of DES residues in environmental and agricultural samples in previous paper. In this paper, an indirect competitive enzyme-linked immunosorbent assay (icELISA) was developed based on monoclonal antibody (MAb) for the determination of diethylstilbestrol. Mono-o-carboxypropyldiethylstilbestrol (DES-CP) and mono-o-carboxymethyldiethylstilbestrol (DES-CME) were synthesized to be haptens. DES-CP was coupled to bovine serum albumin (BSA) to be an immunogen in BALB/c female mouse for MAb production. The MAb was characterized for specificity and affinity to DES in icELISA. Under the optimum condition, the icELISA showed an ICs0 of 9.8 ng/mL, the limit of detection (IC20) of 2.3 ng/mL and a working range of 2-42 ng/mL. Hexestrol and dienestrol exhibited cross-reactivity values were 44% and 27%, respectively. Cross-reactivity of natural estrogen 17β-estradiol was less than 0.1%. The influences of some factors such as salt concentration, pH and organic solvent concentration on the assay were evaluated. The concentrations of DES in the fortified water samples determined by the assay were correlated well with the fortification levels. The results were conf'm'ned with analysis by HPLC.
基金Basic and Applied Basic Research Foundation of Guangdong Province,Grant/Award Number:2023A1515010702National Natural Science Foundation of China,Grant/Award Numbers:31870981,82020108016+2 种基金Innovation and Technology Commission,Grant/Award Number:ITC-CNERC14SC01Research Grants Council,University Grants Committee,Grant/Award Numbers:16306620,GRF 16209820STU Scientific Research Initiation Grant,Grant/Award Number:NTF22023。
文摘Cytokine monitoring has attracted great attention due to its significance in the diagnosis and treatment of many diseases,such as tumors,microbial infections,and immunological diseases.Enzyme-linked immunosorbent assay(ELISA)is one of the most popular methods in cytokine detection,ascribing to the lavish signal amplification methods in the ELISA platform.In addition to classical enzymes,other signal amplifiers such as fluorescent probes,artificial nano-enzymes,and photothermal reagents have been applied to reduce the detection limit and produce more sensitive ELISA kits.Due to the accumulative effect of heat,photothermal reagents are promising materials in the signal amplification of ELISA.However,the lack of efficient photothermal generation material at an aggregate scale may delay the further development of this area.In this contribution,based on an efficient organic photothermal aggregate material,an enzyme-free photothermally amplified fluorescent immunosorbent assay system consisting of an assay microfluidic chip and detecting platform was developed.The photothermal nanoparticles with highly efficient photothermal conversion by harvesting energy via excited-state intramolecular motions and enlarging molar absorptivity were successfully prepared.The detection concentration at 50 pg/mL of interleukin-2 was achieved,realizing a signal improvement of detection limits by 20-fold compared to that of previously reported photothermal ELISA.The microscopic imaging integrated with plane sweeping technology provided high spatial resolution and precision,indicating the potential of achieving high throughput profiling at the microscale.Moreover,as an alternative excitation source,light-emitting diode not only provided a more affordable and miniaturized detection system but also revealed the great feasibility of intramolecular motion-induced photothermy nanoparticles for biological analyses.
基金This work was supported by the National High-Tech Research and Development(863)Program of China(2002AA649160).
文摘Microcystins(MCs)are a group of closely related toxic cyclic heptapeptides produced by common cyanobacte-ria,which cause lots of accidents and threatens human health.In this paper,an indirect competitive enzyme-linked immu-nosorbent assay(ic-ELISA)was established and used to detect microcystin-LR(MC-LR)in drinking and surface waters.The concentration of coating antigen was 5 mg/mL,the dilution of monoclonal antibody MC10E7 was 1:3000,the dilution of enzyme tracer(goat anti-mouse IgG-peroxidase)was 1:3000,the standard concentration of MC-LR ranged from 0.001 mg/L to 30 mg/L,and o-phenylenediamine was used as substrate.The assay showed high relativity with high performance liquid chromatography(HPLC)with a correlation coefficient of more than 99%.The relative standard deviation was less than 10%,the detection limit was achieved down to 0.01 mg/L and up to 5.1 mg/L.The quantitative detection range was from 0.03 mg/L to 3 mg/L,and the antibody had high specificity for[4-arginine]microcystins.It performed well in spite of the influence of the real samples.
文摘Background Severe acute respiratory syndrome coronavirus (SARS-CoV) is a newly emerging virus that gives rise to SARS patients with high rates of infectivity and fatality. To study the humoral immune responses to SARS-CoV, the authors evaluated IgG and IgM specific antibodies in patients’ sera.Methods Two methods, enzyme-linked immunosorbent assay (ELISA) and indirect immunofluorescent assay (IFA), were used to detect specific serum IgG and IgM against SARS-CoV in 98 SARS patients and 250 controls consisting of patients with pneumonia, health-care professionals and healthy subjects. The serum antibody profiles were investigated at different times over one and a half years in 18 of the SARS patients. Results The sensitivity and specificity of ELISA for detecting IgG against SARS-CoV were 100.0% and 97.2% and for IgM 89.8% and 97.6% respectively; the figures using IFA for IgG were 100.0% and 100.0% and for IgM 81.8% and 100.0% respectively. During the first seven days of the antibodies trace test, no IgG and IgM were detected, but on day 15, IgG response increased dramatically, reaching a peak on day 60, remaining high up to day 180 and decreasing gradually until day 540. On day 15, IgM was detected, rapidly reached a peak, then declined gradually until day 180 when IgM was undetectable. Conclusion The detection of antibodies against SARS virus is helpful in the clinical diagnosis of SARS.
基金This work was supported by the following grants:the National Major Project for Control and Prevention of Infectious Disease in China(No.2018ZX10101002 and 2018ZX10732401)the National Key Research and Development Program of China(No.2016YFD0500301 and 2017YFC1200503)。
文摘The Middle East respiratory syndrome(MERS)is a lethal zoonosis caused by MERS coronavirus(MERS-CoV)and poses a significant threat to public health worldwide.Therefore,a rapid,sensitive,and specific serologic test for detecting anti-MERS-CoV antibodies in both humans and animals is urgently needed for the successful management of this illness.Here,we evaluated various novel luciferase immunosorbent assays(LISA)based on nucleocapsid protein(NP)as well as fragments derived from spike protein(S)including subunit 1(S1),N terminal domain(NTD),receptorbinding domain(RBD)and subunit 2(S2)of S for the detection of MERS-CoV-specific IgG.Fusion proteins,including nanoluciferase(NLuc)and various fragments derived from the NP or S protein of MERS-CoV,were expressed in human embryonic kidney 293 T cells.LISAs that detected anti-MERS-CoV IgG were further developed using cell lysates expressing various fusion proteins.Panels of human or animal samples infected with MERS-CoV were used to analyze the sensitivity and specificity of various LISAs in reference to a MERS-CoV RT-PCR,commercial S1-based ELISA,and pseudovirus particle neutralization test(ppNT).Our results showed that the S1-,RBD-,and NP-LISAs were more sensitive than the NTD-and S2-LISAs for the detection of anti-MERS-CoV IgG.Furthermore,the S1-,RBD-,and NP-LISAs were more sensitive(by at least 16-fold)than the commercially available S1-ELISA.Moreover,the S1-,RBD-,and NPLISA specifically recognized anti-MERS-CoV IgG and did not cross-react with samples derived from other human CoV(OC43,229E,HKU1,NL63)-infected patients.More importantly,these LISAs proved their applicability and reliability for detecting anti-MERS-CoV IgG in samples from camels,monkeys,and mice,among which the RBD-LISA exhibited excellent performance.The results of this study suggest that the novel MERS-CoV RBD-and S1-LISAs are highly effective platforms for the rapid and sensitive detection of anti-MERS-CoV IgG in human and animal samples.These assays have the potential to be used as serologic tests for the management and control of MERS-CoV infection.