Inverse synthetic aperture radar (ISAR) image can be represented and reconstructed by sparse recovery (SR) approaches. However, the existing SR algorithms, which are used for ISAR imaging, have suffered from high comp...Inverse synthetic aperture radar (ISAR) image can be represented and reconstructed by sparse recovery (SR) approaches. However, the existing SR algorithms, which are used for ISAR imaging, have suffered from high computational cost and poor imaging quality under a low signal to noise ratio (SNR) condition. This paper proposes a fast decoupled ISAR imaging method by exploiting the inherent structural sparse information of the targets. Firstly, the ISAR imaging problem is decoupled into two sub-problems. One is range direction imaging and the other is azimuth direction focusing. Secondly, an efficient two-stage SR method is proposed to obtain higher resolution range profiles by using jointly sparse information. Finally, the residual linear Bregman iteration via fast Fourier transforms (RLBI-FFT) is proposed to perform the azimuth focusing on low SNR efficiently. Theoretical analysis and simulation results show that the proposed method has better performence to efficiently implement higher-resolution ISAR imaging under the low SNR condition.展开更多
BACKGROUND Rectal cancer is a common malignant tumor of the digestive system,with older patients representing the predominantly affected population.Magnetic resonance imaging(MRI)has been widely applied in preoperativ...BACKGROUND Rectal cancer is a common malignant tumor of the digestive system,with older patients representing the predominantly affected population.Magnetic resonance imaging(MRI)has been widely applied in preoperative tumor assessment;however,the value of high-resolution MRI(HR-MRI)combined with dynamic contrast-enhanced(DCE)scanning in the preoperative diagnosis of rectal cancer in older patients remains unclear.AIM To evaluate the value of HR-MRI combined with DCE scanning in the preoperative diagnosis of rectal cancer in older patients.METHODS This retrospective study included 148 consecutive older female patients with rectal cancer who were treated at our hospital between December 2020 and December 2024.Clinical data and HR-MRI and DCE scan findings were collected.Histopathological examination after surgical resection served as the gold standard.The diagnostic accuracy of MRI for preoperative T and N staging was calculated.Consistency,sensitivity,and specificity between HR-MRI combined with DCE scanning and pathological staging were analyzed using the k test.Among the 148 patients,the overall accuracy of T staging was 84.5%.Sensitivity for T1,T2,T3,and T4 staging was 75.00%,62.50%,89.47%,and 90.48%,respectively,whereas specificity was 100.00%,94.35%,79.25%,and 96.06%,respectively.T staging based on HR-MRI combined with DCE scanning showed good agreement with pathological staging(k=0.8176,P<0.001).For N staging,sensitivity and specificity were 54.88%and 84.85%for N0,36.96%and 72.55%for N1,and 70.00%and 73.44%for N2,respectively;agreement with pathological N staging was poor(k=0.259,P<0.001).CONCLUSION HR-MRI combined with DCE scanning demonstrates high diagnostic accuracy for T staging of rectal cancer in older patients and can provide a theoretical basis for treatment planning.However,its diagnostic accuracy for N staging requires improvement.展开更多
Transforming a scattering medium into a lens for imaging very simple binary objects is possible;however,it remains challenging to image complex grayscale objects,let alone measure 3D continuous distribution objects.He...Transforming a scattering medium into a lens for imaging very simple binary objects is possible;however,it remains challenging to image complex grayscale objects,let alone measure 3D continuous distribution objects.Here,we propose and demonstrate the use of a ground glass diffuser as a scattering lens for imaging complex grayscale fringes,and we employ it to achieve microscopic structured light 3D imaging(MSL3DI).The ubiquitous property of the speckle patterns permits the exploitation of the scattering medium as an ultra-thin scattering lens with a variable focal length and a flexible working distance for microscale object measurement.The method provides a light,flexible,and cost-effective imaging device as an alternative to microscope objectives or telecentric lenses in conventional MSL3DI systems.We experimentally demonstrate that employing a scattering lens allows us to achieve relatively good phase information and robust 3D imaging from depth measurements,yielding measurement accuracy only marginally lower than that of a telecentric lens,typically within approximately 10μm.Furthermore,the scattering lens demonstrates robust performance even when the imaging distance exceeds the typical working distance of a telecentric lens.The proposed method facilitates the application of scattering imaging techniques,providing a more flexible solution for MSL3DI.展开更多
We report a study on the electronic structure and chemical bonding of the PB and AsB diatomic molecules using high-resolution photoelectron imaging of cryogenically-cooled PB^(−)and AsB^(−)anions.The electron affiniti...We report a study on the electronic structure and chemical bonding of the PB and AsB diatomic molecules using high-resolution photoelectron imaging of cryogenically-cooled PB^(−)and AsB^(−)anions.The electron affinities of PB and AsB are measured to be 2.751(1)and 2.600(1)eV,respectively.The ground states of the PB^(−)and AsB−anions are determined to be ^(2)Σ^(+) with a σ^(1)π^(4) valence electron configuration.The ground states of neutral PB and AsB are found to be ^(3)Π_(2) with a σ^(1)π^(3) electron configuration.The spin-orbit excited states(^(3)Π_(1) and ^(3)Π_(0)),as well as two low-lying singlet excited states(^(1)Σ^(+)and ^(1)Π),are observed.Unusual spectroscopic characteristics are observed in the ^(3)Π_(2) ground state of AsB,probably due to state mixing with a higher-lying ^(1)Δ_(2) state.The current work provides extensive electronic and spectroscopic information for the PB and AsB molecules.展开更多
Structural Health Monitoring(SHM)systems play a key role in managing buildings and infrastructure by delivering vital insights into their strength and structural integrity.There is a need for more efficient techniques...Structural Health Monitoring(SHM)systems play a key role in managing buildings and infrastructure by delivering vital insights into their strength and structural integrity.There is a need for more efficient techniques to detect defects,as traditional methods are often prone to human error,and this issue is also addressed through image processing(IP).In addition to IP,automated,accurate,and real-time detection of structural defects,such as cracks,corrosion,and material degradation that conventional inspection techniques may miss,is made possible by Artificial Intelligence(AI)technologies like Machine Learning(ML)and Deep Learning(DL).This review examines the integration of computer vision and AI techniques in Structural Health Monitoring(SHM),investigating their effectiveness in detecting various forms of structural deterioration.Also,it evaluates ML and DL models in SHM for their accuracy in identifying and assessing structural damage,ultimately enhancing safety,durability,and maintenance practices in the field.Key findings reveal that AI-powered approaches,especially those utilizing IP and DL models like CNNs,significantly improve detection efficiency and accuracy,with reported accuracies in various SHM tasks.However,significant research gaps remain,including challenges with the consistency,quality,and environmental resilience of image data,a notable lack of standardized models and datasets for training across diverse structures,and concerns regarding computational costs,model interpretability,and seamless integration with existing systems.Future work should focus on developing more robust models through data augmentation,transfer learning,and hybrid approaches,standardizing protocols,and fostering interdisciplinary collaboration to overcome these limitations and achieve more reliable,scalable,and affordable SHM systems.展开更多
A profile of shallow crustal velocity structure(1–2 km) may greatly enhance interpretation of the sedimentary environment and shallow tectonic deformation.Recent advances in surface wave tomography, using ambient noi...A profile of shallow crustal velocity structure(1–2 km) may greatly enhance interpretation of the sedimentary environment and shallow tectonic deformation.Recent advances in surface wave tomography, using ambient noise data recorded with high-density seismic arrays, have improved the understanding of regional crustal structure. As the interest in detailed shallow crustal structure imaging has increased, dense seismic array methods have become increasingly efficient. This study used a high-density seismic array deployed in the Xinjiang basin in southeastern China, to record seismic data, which was then processed with the ambient noise tomography method. The high-density seismic array contained 203 short-period seismometers, spaced at short intervals(~ 400 m). The array collected continuous records of ambient noise for 32 days. Data preprocessing,cross correlation calculation, and Rayleigh surface wave phase-velocity dispersion curve extraction, yielded more than 16,000 Rayleigh surface wave phase-velocity dispersion curves, which were then analyzed using the direct-inversion method. Checkerboard tests indicate that the shear wave velocity is recovered in the study area, at depths of 0–1.4 km,with a lateral image resolution of ~ 400 m. Model test results show that the seismic array effectively images a 50 m thick slab at a depth of 0–300 m, a 150 m thick anomalous body at a depth of 300–600 m, and a 400 m thick anomalous body at a depth of 0.6–1.4 km. The shear wave velocity profile reveals features very similar to those detected by a deep seismic reflection profile across the study area. This demonstrates that analysis of shallow crustal velocity structure provides high-resolution imaging of crustal features.Thus, ambient noise tomography with a high-density seismic array may play an important role in imaging shallow crustal structure.展开更多
In this paper,we proposed a monopulse forward-looking high-resolution imaging algorithm based on adaptive iteration for missile-borne detector.Through iteration,the proposed algorithm automatically selects the echo si...In this paper,we proposed a monopulse forward-looking high-resolution imaging algorithm based on adaptive iteration for missile-borne detector.Through iteration,the proposed algorithm automatically selects the echo signal of isolated strong-scattering points from the receiving echo signal data to accurately estimate the actual optimal monopulse response curve(MRC) of the same distance range,and we applied optimal MRC to realize the azimuth self-focusing in the process of imaging.We use real-time echo data to perform error correction for obtaining the optimal MRC,and the azimuth angulation accuracy may reach the optimum at a certain distance dimension.We experimentally demonstrate the validity,reliability and high performance of the proposed algorithm.The azimuth angulation accuracy may reach up to ten times of the detection beam-width.The simulation experiments have verified the feasibility of this strategy,with the average height measurement error being 7.8%.In the out-field unmanned aerial vehicle(UAV) tests,the height measurement error is less than 25 m,and the whole response time can satisfy the requirements of a missile-borne detector.展开更多
The structured low-rank model for parallel magnetic resonance(MR)imaging can efficiently reconstruct MR images with limited auto-calibration signals.To improve the reconstruction quality of MR images,we integrate the ...The structured low-rank model for parallel magnetic resonance(MR)imaging can efficiently reconstruct MR images with limited auto-calibration signals.To improve the reconstruction quality of MR images,we integrate the joint sparsity and sparsifying transform learning(JTL)into the simultaneous auto-calibrating and k-space estimation(SAKE)structured low-rank model,named JTLSAKE.The alternate direction method of multipliers is exploited to solve the resulting optimization problem,and the optimized gradient method is used to improve the convergence speed.In addition,a graphics processing unit is used to accelerate the proposed algorithm.The experimental results on four in vivo human datasets demonstrate that the reconstruction quality of the proposed algorithm is comparable to that of JTL-based low-rank modeling of local k-space neighborhoods with parallel imaging(JTL-PLORAKS),and the proposed algorithm is 46 times faster than the JTL-PLORAKS,requiring only 4 s to reconstruct a 200×200 pixels MR image with 8 channels.展开更多
Aiming at a novel missile-borne detector in the optional burst height proximity fuze, a self-adaptive high-resolution forward-looking imaging algorithm (SAHRFL-IA) is presented. The echo data are captured by the missi...Aiming at a novel missile-borne detector in the optional burst height proximity fuze, a self-adaptive high-resolution forward-looking imaging algorithm (SAHRFL-IA) is presented. The echo data are captured by the missile-borne detector in the target regions;thereby the azimuth angulation accuracy at the same distance dimension is improved dynamically. Thus, azimuth information of the targets in the detection area may be obtained accurately. The proposed imaging algorithm breaks through the conventional misconception of merely using azimuth discrimination curves under ideal conditions during monopulse angulation. The real-time echo data from the target region are used to perform error correction for this discrimination curve, and finally the accuracy of the azimuth angulation may reach the optimum at the same distance dimension. A series of experiments demonstrate the validity, reliability and high performance of the proposed imaging algorithm. Azimuth angulation accuracy may reach ten times that of the detection beam width. Meanwhile, the running time of this algorithm satisfies the requirements of missile-borne platforms.展开更多
Mass spectrometry imaging (MSI) technology can simultaneously obtain the spatial distribution of thousands of chemical compounds and has unique advantages compared to other techniques that allow mapping the surface of...Mass spectrometry imaging (MSI) technology can simultaneously obtain the spatial distribution of thousands of chemical compounds and has unique advantages compared to other techniques that allow mapping the surface of bio-tissue. Here, we combined an air flow-assisted desorption electrospray ionization (AFADESI) MSI device with a high-resolution mass spectrometer to optimize the system parameters and achieve more accurate spatial distribution characteristics for compounds of interest while investigating bio-tissue sections. The platform set-up, required instrumentation, sample pretreatment, parameter optimization and bio-tissue characterization are described and discussed.Finally, the parameter conditions that can provide optimal ionic intensity and enhanced resolution were confirmed. The reasonable resolution and sensitivity improvements of AFADESI-MSI have been achieved through tandem a high-resolution mass spectrometer system, therefore, it would be a promising technique for the bio-tissue imaging analysis.展开更多
BACKGROUND Intracranial atherosclerosis,a leading cause of stroke,involves arterial plaque formation.This study explores the link between plaque remodelling patterns and diabetes using high-resolution vessel wall imag...BACKGROUND Intracranial atherosclerosis,a leading cause of stroke,involves arterial plaque formation.This study explores the link between plaque remodelling patterns and diabetes using high-resolution vessel wall imaging(HR-VWI).AIM To investigate the factors of intracranial atherosclerotic remodelling patterns and the relationship between intracranial atherosclerotic remodelling and diabetes mellitus using HR-VWI.METHODS Ninety-four patients diagnosed with middle cerebral artery or basilar artery INTRODUCTION Intracranial atherosclerotic disease is one of the main causes of ischaemic stroke in the world,accounting for approx-imately 10%of transient ischaemic attacks and 30%-50%of ischaemic strokes[1].It is the most common factor among Asian people[2].The adaptive changes in the structure and function of blood vessels that can adapt to changes in the internal and external environment are called vascular remodelling,which is a common and important pathological mechanism in atherosclerotic diseases,and the remodelling mode of atherosclerotic plaques is closely related to the occurrence of stroke.Positive remodelling(PR)is an outwards compensatory remodelling where the arterial wall grows outwards in an attempt to maintain a constant lumen diameter.For a long time,it was believed that the degree of stenosis can accurately reflect the risk of ischaemic stroke[3-5].Previous studies have revealed that lesions without significant luminal stenosis can also lead to acute events[6,7],as summarized in a recent meta-analysis study in which approximately 50%of acute/subacute ischaemic events were due to this type of lesion[6].Research[8,9]has pointed out that the PR of plaques is more dangerous and more likely to cause acute ischaemic stroke.Previous studies[10-13]have found that there are specific vascular remodelling phenomena in the coronary and carotid arteries of diabetic patients.However,due to the deep location and small lumen of intracranial arteries and limitations of imaging techniques,the relationship between intracranial arterial remodelling and diabetes is still unclear.In recent years,with the development of magnetic resonance technology and the emergence of high-resolution(HR)vascular wall imaging,a clear and multidimensional display of the intracranial vascular wall has been achieved.Therefore,in this study,HR wall imaging(HR-VWI)was used to display the remodelling characteristics of bilateral middle cerebral arteries and basilar arteries and to explore the factors of intracranial vascular remodelling and its relationship with diabetes.展开更多
Amblyopia is the most common cause of vision loss in children and can persist into adulthood in the absence of effective intervention.Previous clinical and neuroimaging studies have suggested that the neural mechanism...Amblyopia is the most common cause of vision loss in children and can persist into adulthood in the absence of effective intervention.Previous clinical and neuroimaging studies have suggested that the neural mechanisms underlying strabismic amblyopia and anisometropic amblyopia may be different.Therefore,we performed a systematic review of magnetic resonance imaging studies investigating brain alterations in patients with these two subtypes of amblyopia;this study is registered with PROSPERO(registration ID:CRD42022349191).We searched three online databases(PubMed,EMBASE,and Web of Science) from inception to April 1,2022;39 studies with 633 patients(324patients with anisometropic amblyo pia and 309 patients with strabismic amblyopia) and 580 healthy controls met the inclusion criteria(e.g.,case-control designed,pee r-reviewed articles) and were included in this review.These studies highlighted that both strabismic amblyopia and anisometropic amblyopia patients showed reduced activation and distorted topological cortical activated maps in the striate and extrastriate co rtices during tas k-based functional magnetic resonance imaging with spatial-frequency stimulus and retinotopic representations,respectively;these may have arisen from abnormal visual experiences.Compensations for amblyopia that are reflected in enhanced spontaneous brain function have been reported in the early visual cortices in the resting state,as well as reduced functional connectivity in the dorsal pathway and structural connections in the ventral pathway in both anisometro pic amblyopia and strabismic amblyopia patients.The shared dysfunction of anisometro pic amblyopia and strabismic amblyopia patients,relative to controls,is also chara cterized by reduced spontaneous brain activity in the oculomotor co rtex,mainly involving the frontal and parietal eye fields and the cerebellu m;this may underlie the neural mechanisms of fixation instability and anomalous saccades in amblyopia.With regards to specific alterations of the two forms of amblyo pia,anisometropic amblyo pia patients suffer more microstructural impairments in the precortical pathway than strabismic amblyopia patients,as reflected by diffusion tensor imaging,and more significant dysfunction and structural loss in the ventral pathway.Strabismic amblyopia patients experience more attenuation of activation in the extrastriate co rtex than in the striate cortex when compared to anisometropic amblyopia patients.Finally,brain structural magnetic resonance imaging alterations tend to be lateralized in the adult anisometropic amblyopia patients,and the patterns of brain alterations are more limited in amblyopic adults than in childre n.In conclusion,magnetic resonance imaging studies provide important insights into the brain alterations underlying the pathophysiology of amblyopia and demonstrate common and specific alte rations in anisometropic amblyo pia and strabismic amblyopia patients;these alterations may improve our understanding of the neural mechanisms underlying amblyopia.展开更多
Applications of multifractal analysis to white matter structure changes on magnetic resonance imaging(MRI) have recently received increasing attentions. Although some progresses have been made, there is no evident s...Applications of multifractal analysis to white matter structure changes on magnetic resonance imaging(MRI) have recently received increasing attentions. Although some progresses have been made, there is no evident study on applying multifractal analysis to evaluate the white matter structural changes on MRI for Alzheimer's disease(AD) research. In this paper, to explore multifractal analysis of white matter structural changes on 3D MRI volumes between normal aging and early AD, we not only extend the traditional box-counting multifractal analysis(BCMA) into the 3D case, but also propose a modified integer ratio based BCMA(IRBCMA) algorithm to compensate for the rigid division rule in BCMA. We verify multifractal characteristics in 3D white matter MRI volumes. In addition to the previously well studied multifractal feature,△α, we also demonstrated △ f as an alternative and effective multifractal feature to distinguish NC from AD subjects.Both △α and △ f are found to have strong positive correlation with the clinical MMSE scores with statistical significance.Moreover, the proposed IRBCMA can be an alternative and more accurate algorithm for 3D volume analysis. Our findings highlight the potential usefulness of multifractal analysis, which may contribute to clarify some aspects of the etiology of AD through detection of structural changes in white matter.展开更多
BACKGROUND The main clinical manifestation of Alzheimer’s disease(AD)is memory loss,which can be accompanied by neuropsychiatric symptoms at different stages of the disease.Amygdala is closely related to emotion and ...BACKGROUND The main clinical manifestation of Alzheimer’s disease(AD)is memory loss,which can be accompanied by neuropsychiatric symptoms at different stages of the disease.Amygdala is closely related to emotion and memory.AIM To evaluate the diagnostic value of amygdala on structural magnetic resonance imaging(sMRI)for AD.METHODS In this study,22 patients with AD and 26 controls were enrolled.Their amygdala volumes were measured by sMRI and analyzed using an automatic analysis software.RESULTS The bilateral amygdala volumes of AD patients were significantly lower than those of the controls and were positively correlated with the hippocampal volumes.Receiver operating characteristic curve analyses showed that the sensitivity of the left and right amygdala volumes in diagnosing AD was 80.8%and 88.5%,respectively.Subgroup analyses showed that amygdala atrophy was more serious in AD patients with neuropsychiatric symptoms,which mainly included irritability(22.73%),sleep difficulties(22.73%),apathy(18.18%),and hallucination(13.64%).CONCLUSION Amygdala volumes measured by sMRI can be used to diagnose AD,and amygdala atrophy is more serious in patients with neuropsychiatric symptoms.展开更多
BACKGROUND Vertebral artery dissection(VAD)is a rare but life-threatening condition characterized by tearing of the intimal layer of the vertebral artery,leading to stenosis,occlusion or rupture.The clinical presentat...BACKGROUND Vertebral artery dissection(VAD)is a rare but life-threatening condition characterized by tearing of the intimal layer of the vertebral artery,leading to stenosis,occlusion or rupture.The clinical presentation of VAD can be heterogeneous,with common symptoms including headache,dizziness and balance problems.Timely diagnosis and treatment are crucial for favorable outcomes;however,VAD is often missed due to its variable clinical presentation and lack of robust diagnostic guidelines.High-resolution magnetic resonance imaging(HRMRI)has emerged as a reliable diagnostic tool for VAD,providing detailed visualization of vessel wall abnormalities.CASE SUMMARY A young male patient presented with an acute onset of severe headache,vomiting,and seizures,followed by altered consciousness.Imaging studies revealed bilateral VAD,basilar artery thrombosis,multiple brainstem and cerebellar infarcts,and subarachnoid hemorrhage.Digital subtraction angiography(DSA)revealed vertebral artery stenosis but failed to detect the dissection,potentially because intramural thrombosis obscured the VAD.In contrast,HRMRI confirmed the diagnosis by revealing specific signs of dissection.The patient was managed conservatively with antiplatelet therapy and other supportive measures,such as blood pressure control and pain management.After 5 mo of rehabilitation,the patient showed significant improvement in swallowing and limb strength.CONCLUSION HR-MRI can provide precise evidence for the identification of VAD.展开更多
Structures and crystal form transition of the novel aryl ether ketone polymer containing meta-phenylene linkage: PEKEKK(T/I) were investigated by wide angle X-ray diffraction (WAXD), imaging plates (IPs) and small ang...Structures and crystal form transition of the novel aryl ether ketone polymer containing meta-phenylene linkage: PEKEKK(T/I) were investigated by wide angle X-ray diffraction (WAXD), imaging plates (IPs) and small angle X-ray scattering (SAXS). The energy of activation of the decomposition reaction and degree of crystallinity of PEKEKK(T/I) were determined by WAXD and thermo-gravimetric analysis (TGA), respectively. Results obtained from WAXD and IPs show that crystal forms coexist in the PEKEKK(T/I) samples isothermally cold crystallized in the temperature range from 180'C to 240T? and only form occurs in PEKEKK(TTI) samples isothermally cold crystallized at 2701C. The radius of gyration (Rg), thickness of microregions with electron-density fluctuations (E) and distribution of particle sizes were investigated by SAXS.展开更多
AIM:To evaluate a high-resolution functional imaging device that yields quantitative data regarding macular blood flow and capillary network features in eyes with diabetic retinopathy(DR).METHODS:Prospective,cross-sec...AIM:To evaluate a high-resolution functional imaging device that yields quantitative data regarding macular blood flow and capillary network features in eyes with diabetic retinopathy(DR).METHODS:Prospective,cross-sectional comparative case-series in which blood flow velocities(BFVs)and noninvasive capillary perfusion maps(nCPMs)in macular vessels were measured in patients with DR and in healthy controls using the Retinal Functional Imager(RFI)device.RESULTS:A total of 27 eyes of 21 subjects were studied[9 eyes nonproliferative diabetic retinopathy(NPDR),9 eyes proliferative diabetic retinopathy(PDR)and 9 controls].All diabetic patients were type 2.All patients with NPDR and 5 eyes with PDR also had diabetic macular edema(DME).The NPDR group included eyes with severe(n=3)and moderate NPDR(n=6),and were symptomatic.A significant decrease in venular BFVs was observed in the macular region of PDR eyes when compared to controls(2.61±0.6 mm/s and 2.92±0.72 mm/s in PDR and controls,respectively,P=0.019)as well as PDR eyes with DME compared to NPDR eyes(2.36±0.51 mm/s and 2.94±1.09 mm/s in PDR with DME and NPDR,respectively,P=0.01).CONCLUSION:The RFI,a non-invasive imaging tool,provides high-resolution functional imaging of the retinal microvasculature and quantitative measurement of BFVs in visually impaired DR patients.The isolated diminish venular BFVs in PDR eyes compared to healthy eyes and PDR eyes with DME in comparison to NPDR eyes may indicate the possibility of more retinal vein compromise than suspected in advanced DR.展开更多
This paper describes the control software together with the operational hardware, which successfully realizes the operation of a new fully programmable imaging system with high spatial and temporal resolutions on the ...This paper describes the control software together with the operational hardware, which successfully realizes the operation of a new fully programmable imaging system with high spatial and temporal resolutions on the KT5D magnetic torus, for observing the visible l ight emission from the plasma discharge.展开更多
Single-cell imaging,a powerful analytical method to study single-cell behavior,such as gene expression and protein profiling,provides an essential basis for modern medical diagnosis.The coding and localization functio...Single-cell imaging,a powerful analytical method to study single-cell behavior,such as gene expression and protein profiling,provides an essential basis for modern medical diagnosis.The coding and localization function of microfluidic chips has been developed and applied in living single-cell imaging in recent years.Simultaneously,chip-based living single-cell imaging is also limited by complicated trapping steps,low cell utilization,and difficult high-resolution imaging.To solve these problems,an ultra-thin temperature-controllable microwell array chip(UTCMA chip)was designed to develop a living single-cell workstation in this study for continuous on-chip culture and real-time high-resolution imaging of living single cells.The chip-based on ultra-thin ITO glass is highly matched with an inverted microscope(or confocal microscope)with a high magnification objective(100×oil lens),and the temperature of the chip can be controlled by combining it with a home-made temperature control device.High-throughput single-cell patterning is realized in one step when the microwell array on the chip uses hydrophilic glass as the substrate and hydrophobic SU-8 photoresist as the wall.The cell utilization rate,single-cell capture rate,and microwell occupancy rate are all close to 100%in the microwell array.This method will be useful in rare single-cell research,extending its application in the biological and medical-related fields,such as early diagnosis of disease,personalized therapy,and research-based on single-cell analysis.展开更多
In addition to the tens of millions of medical doses consumed annually around the world,a vast number of nuclear magnetic resonance imaging(MRI)contrast agents are being deployed in MRI research and development,offeri...In addition to the tens of millions of medical doses consumed annually around the world,a vast number of nuclear magnetic resonance imaging(MRI)contrast agents are being deployed in MRI research and development,offering precise diagnostic information,targeting capabilities,and analyte sensing.Superparamagnetic iron oxide nanoparticles(SPIONs)are notable among these agents,providing effective and versatile MRI applications while also being heavy-metal-free,bioconjugatable,and theranostic.We designed and implemented a novel two-pronged computational and experimental strategy to meet the demand for the efficient and rigorous development of SPION-based MRI agents.Our MATLAB-based modeling simulation and magnetic characterization revealed that extremely small maghemite SPIONs in the 1-3 nm range possess significantly reduced transversal relaxation rates(R_(2))and are therefore preferred for positive(T_(1)-weighted)MRI.Moreover,X-ray diffraction and X-ray absorption fine structure analyses demonstrated that the diffraction pattern and radial distribution function of our SPIONs matched those of the targeted maghemite crystals.In addition,simulations of the X-ray near-edge structure spectra indicated that our synthesized SPIONs,even at 1 nm,maintained a spherical structure.Furthermore,in vitro and in vivo MRI investigations showed that our 1-nm SPIONs effectively highlighted whole-body blood vessels and major organs in mice and could be cleared through the kidney route to minimize potential post-imaging side effects.Overall,our innovative approach enabled a swift discovery of the desired SPION structure,followed by targeted synthesis,synchrotron radiation spectroscopic studies,and MRI evaluations.The efficient and rigorous development of our high-performance SPIONs can set the stage for a computational and experimental platform for the development of future MRI agents.展开更多
基金supported by the National Natural Science Foundation of China(61671469)
文摘Inverse synthetic aperture radar (ISAR) image can be represented and reconstructed by sparse recovery (SR) approaches. However, the existing SR algorithms, which are used for ISAR imaging, have suffered from high computational cost and poor imaging quality under a low signal to noise ratio (SNR) condition. This paper proposes a fast decoupled ISAR imaging method by exploiting the inherent structural sparse information of the targets. Firstly, the ISAR imaging problem is decoupled into two sub-problems. One is range direction imaging and the other is azimuth direction focusing. Secondly, an efficient two-stage SR method is proposed to obtain higher resolution range profiles by using jointly sparse information. Finally, the residual linear Bregman iteration via fast Fourier transforms (RLBI-FFT) is proposed to perform the azimuth focusing on low SNR efficiently. Theoretical analysis and simulation results show that the proposed method has better performence to efficiently implement higher-resolution ISAR imaging under the low SNR condition.
基金Supported by Tianjin Key Medical Discipline(Specialty)Construction Project,No.TJYXZDXK-3-012B.
文摘BACKGROUND Rectal cancer is a common malignant tumor of the digestive system,with older patients representing the predominantly affected population.Magnetic resonance imaging(MRI)has been widely applied in preoperative tumor assessment;however,the value of high-resolution MRI(HR-MRI)combined with dynamic contrast-enhanced(DCE)scanning in the preoperative diagnosis of rectal cancer in older patients remains unclear.AIM To evaluate the value of HR-MRI combined with DCE scanning in the preoperative diagnosis of rectal cancer in older patients.METHODS This retrospective study included 148 consecutive older female patients with rectal cancer who were treated at our hospital between December 2020 and December 2024.Clinical data and HR-MRI and DCE scan findings were collected.Histopathological examination after surgical resection served as the gold standard.The diagnostic accuracy of MRI for preoperative T and N staging was calculated.Consistency,sensitivity,and specificity between HR-MRI combined with DCE scanning and pathological staging were analyzed using the k test.Among the 148 patients,the overall accuracy of T staging was 84.5%.Sensitivity for T1,T2,T3,and T4 staging was 75.00%,62.50%,89.47%,and 90.48%,respectively,whereas specificity was 100.00%,94.35%,79.25%,and 96.06%,respectively.T staging based on HR-MRI combined with DCE scanning showed good agreement with pathological staging(k=0.8176,P<0.001).For N staging,sensitivity and specificity were 54.88%and 84.85%for N0,36.96%and 72.55%for N1,and 70.00%and 73.44%for N2,respectively;agreement with pathological N staging was poor(k=0.259,P<0.001).CONCLUSION HR-MRI combined with DCE scanning demonstrates high diagnostic accuracy for T staging of rectal cancer in older patients and can provide a theoretical basis for treatment planning.However,its diagnostic accuracy for N staging requires improvement.
基金supported by the National Natural Science Foundation of China(Grant Nos.62275188 and 62505216)the Central Guidance on Local Science and Technology Development Fund(Grant No.YDZJSX2024D019)+1 种基金the International Scientific and Technological Cooperative Project in Shanxi Province(Grant No.202104041101009)the Natural Science Foundation of Shanxi Province of China through Research Project(Grant No.20210302123195).
文摘Transforming a scattering medium into a lens for imaging very simple binary objects is possible;however,it remains challenging to image complex grayscale objects,let alone measure 3D continuous distribution objects.Here,we propose and demonstrate the use of a ground glass diffuser as a scattering lens for imaging complex grayscale fringes,and we employ it to achieve microscopic structured light 3D imaging(MSL3DI).The ubiquitous property of the speckle patterns permits the exploitation of the scattering medium as an ultra-thin scattering lens with a variable focal length and a flexible working distance for microscale object measurement.The method provides a light,flexible,and cost-effective imaging device as an alternative to microscope objectives or telecentric lenses in conventional MSL3DI systems.We experimentally demonstrate that employing a scattering lens allows us to achieve relatively good phase information and robust 3D imaging from depth measurements,yielding measurement accuracy only marginally lower than that of a telecentric lens,typically within approximately 10μm.Furthermore,the scattering lens demonstrates robust performance even when the imaging distance exceeds the typical working distance of a telecentric lens.The proposed method facilitates the application of scattering imaging techniques,providing a more flexible solution for MSL3DI.
基金supported by the National Science Foundation (Grant No.CHE-2403841)。
文摘We report a study on the electronic structure and chemical bonding of the PB and AsB diatomic molecules using high-resolution photoelectron imaging of cryogenically-cooled PB^(−)and AsB^(−)anions.The electron affinities of PB and AsB are measured to be 2.751(1)and 2.600(1)eV,respectively.The ground states of the PB^(−)and AsB−anions are determined to be ^(2)Σ^(+) with a σ^(1)π^(4) valence electron configuration.The ground states of neutral PB and AsB are found to be ^(3)Π_(2) with a σ^(1)π^(3) electron configuration.The spin-orbit excited states(^(3)Π_(1) and ^(3)Π_(0)),as well as two low-lying singlet excited states(^(1)Σ^(+)and ^(1)Π),are observed.Unusual spectroscopic characteristics are observed in the ^(3)Π_(2) ground state of AsB,probably due to state mixing with a higher-lying ^(1)Δ_(2) state.The current work provides extensive electronic and spectroscopic information for the PB and AsB molecules.
文摘Structural Health Monitoring(SHM)systems play a key role in managing buildings and infrastructure by delivering vital insights into their strength and structural integrity.There is a need for more efficient techniques to detect defects,as traditional methods are often prone to human error,and this issue is also addressed through image processing(IP).In addition to IP,automated,accurate,and real-time detection of structural defects,such as cracks,corrosion,and material degradation that conventional inspection techniques may miss,is made possible by Artificial Intelligence(AI)technologies like Machine Learning(ML)and Deep Learning(DL).This review examines the integration of computer vision and AI techniques in Structural Health Monitoring(SHM),investigating their effectiveness in detecting various forms of structural deterioration.Also,it evaluates ML and DL models in SHM for their accuracy in identifying and assessing structural damage,ultimately enhancing safety,durability,and maintenance practices in the field.Key findings reveal that AI-powered approaches,especially those utilizing IP and DL models like CNNs,significantly improve detection efficiency and accuracy,with reported accuracies in various SHM tasks.However,significant research gaps remain,including challenges with the consistency,quality,and environmental resilience of image data,a notable lack of standardized models and datasets for training across diverse structures,and concerns regarding computational costs,model interpretability,and seamless integration with existing systems.Future work should focus on developing more robust models through data augmentation,transfer learning,and hybrid approaches,standardizing protocols,and fostering interdisciplinary collaboration to overcome these limitations and achieve more reliable,scalable,and affordable SHM systems.
基金supported by the China Geological Survey Project“Deep Geological Survey of the Qin-Hang Belt”(No.DD20160082)the National Natural Science Foundation of China(No.41574048)
文摘A profile of shallow crustal velocity structure(1–2 km) may greatly enhance interpretation of the sedimentary environment and shallow tectonic deformation.Recent advances in surface wave tomography, using ambient noise data recorded with high-density seismic arrays, have improved the understanding of regional crustal structure. As the interest in detailed shallow crustal structure imaging has increased, dense seismic array methods have become increasingly efficient. This study used a high-density seismic array deployed in the Xinjiang basin in southeastern China, to record seismic data, which was then processed with the ambient noise tomography method. The high-density seismic array contained 203 short-period seismometers, spaced at short intervals(~ 400 m). The array collected continuous records of ambient noise for 32 days. Data preprocessing,cross correlation calculation, and Rayleigh surface wave phase-velocity dispersion curve extraction, yielded more than 16,000 Rayleigh surface wave phase-velocity dispersion curves, which were then analyzed using the direct-inversion method. Checkerboard tests indicate that the shear wave velocity is recovered in the study area, at depths of 0–1.4 km,with a lateral image resolution of ~ 400 m. Model test results show that the seismic array effectively images a 50 m thick slab at a depth of 0–300 m, a 150 m thick anomalous body at a depth of 300–600 m, and a 400 m thick anomalous body at a depth of 0.6–1.4 km. The shear wave velocity profile reveals features very similar to those detected by a deep seismic reflection profile across the study area. This demonstrates that analysis of shallow crustal velocity structure provides high-resolution imaging of crustal features.Thus, ambient noise tomography with a high-density seismic array may play an important role in imaging shallow crustal structure.
基金The name of the project that funded this article is 13th Five-Year Plan"equipment pre-research project,the number of this project is 30107030803。
文摘In this paper,we proposed a monopulse forward-looking high-resolution imaging algorithm based on adaptive iteration for missile-borne detector.Through iteration,the proposed algorithm automatically selects the echo signal of isolated strong-scattering points from the receiving echo signal data to accurately estimate the actual optimal monopulse response curve(MRC) of the same distance range,and we applied optimal MRC to realize the azimuth self-focusing in the process of imaging.We use real-time echo data to perform error correction for obtaining the optimal MRC,and the azimuth angulation accuracy may reach the optimum at a certain distance dimension.We experimentally demonstrate the validity,reliability and high performance of the proposed algorithm.The azimuth angulation accuracy may reach up to ten times of the detection beam-width.The simulation experiments have verified the feasibility of this strategy,with the average height measurement error being 7.8%.In the out-field unmanned aerial vehicle(UAV) tests,the height measurement error is less than 25 m,and the whole response time can satisfy the requirements of a missile-borne detector.
基金the Yunnan Fundamental Research Projects(No.202301AT070452)the National Natural Science Foundation of China(No.61861023)。
文摘The structured low-rank model for parallel magnetic resonance(MR)imaging can efficiently reconstruct MR images with limited auto-calibration signals.To improve the reconstruction quality of MR images,we integrate the joint sparsity and sparsifying transform learning(JTL)into the simultaneous auto-calibrating and k-space estimation(SAKE)structured low-rank model,named JTLSAKE.The alternate direction method of multipliers is exploited to solve the resulting optimization problem,and the optimized gradient method is used to improve the convergence speed.In addition,a graphics processing unit is used to accelerate the proposed algorithm.The experimental results on four in vivo human datasets demonstrate that the reconstruction quality of the proposed algorithm is comparable to that of JTL-based low-rank modeling of local k-space neighborhoods with parallel imaging(JTL-PLORAKS),and the proposed algorithm is 46 times faster than the JTL-PLORAKS,requiring only 4 s to reconstruct a 200×200 pixels MR image with 8 channels.
基金supported by the Key Army Pre-research Projects of China(30107030803)
文摘Aiming at a novel missile-borne detector in the optional burst height proximity fuze, a self-adaptive high-resolution forward-looking imaging algorithm (SAHRFL-IA) is presented. The echo data are captured by the missile-borne detector in the target regions;thereby the azimuth angulation accuracy at the same distance dimension is improved dynamically. Thus, azimuth information of the targets in the detection area may be obtained accurately. The proposed imaging algorithm breaks through the conventional misconception of merely using azimuth discrimination curves under ideal conditions during monopulse angulation. The real-time echo data from the target region are used to perform error correction for this discrimination curve, and finally the accuracy of the azimuth angulation may reach the optimum at the same distance dimension. A series of experiments demonstrate the validity, reliability and high performance of the proposed imaging algorithm. Azimuth angulation accuracy may reach ten times that of the detection beam width. Meanwhile, the running time of this algorithm satisfies the requirements of missile-borne platforms.
基金supported by the National Instrumentation Program (No. 2016YFF0100304)the National Natural Science Foundation of China(Nos. 21335007, 81773678)+1 种基金the CAMS Innovation Fund for Medical Sciences(No. 2016-12 M-1-009)PUMC Youth Fund and the Fundamental Research Funds for the Central Universities(No. 3332015177)
文摘Mass spectrometry imaging (MSI) technology can simultaneously obtain the spatial distribution of thousands of chemical compounds and has unique advantages compared to other techniques that allow mapping the surface of bio-tissue. Here, we combined an air flow-assisted desorption electrospray ionization (AFADESI) MSI device with a high-resolution mass spectrometer to optimize the system parameters and achieve more accurate spatial distribution characteristics for compounds of interest while investigating bio-tissue sections. The platform set-up, required instrumentation, sample pretreatment, parameter optimization and bio-tissue characterization are described and discussed.Finally, the parameter conditions that can provide optimal ionic intensity and enhanced resolution were confirmed. The reasonable resolution and sensitivity improvements of AFADESI-MSI have been achieved through tandem a high-resolution mass spectrometer system, therefore, it would be a promising technique for the bio-tissue imaging analysis.
基金Supported by National Natural Science Foundation of China,No.82071871Guangdong Basic and Applied Basic Research Foundation,No.2021A1515220131+1 种基金Guangdong Medical Science and Technology Research Fund Project,No.2022111520491834Clinical Research Project of Shenzhen Second People's Hospital,No.20223357022。
文摘BACKGROUND Intracranial atherosclerosis,a leading cause of stroke,involves arterial plaque formation.This study explores the link between plaque remodelling patterns and diabetes using high-resolution vessel wall imaging(HR-VWI).AIM To investigate the factors of intracranial atherosclerotic remodelling patterns and the relationship between intracranial atherosclerotic remodelling and diabetes mellitus using HR-VWI.METHODS Ninety-four patients diagnosed with middle cerebral artery or basilar artery INTRODUCTION Intracranial atherosclerotic disease is one of the main causes of ischaemic stroke in the world,accounting for approx-imately 10%of transient ischaemic attacks and 30%-50%of ischaemic strokes[1].It is the most common factor among Asian people[2].The adaptive changes in the structure and function of blood vessels that can adapt to changes in the internal and external environment are called vascular remodelling,which is a common and important pathological mechanism in atherosclerotic diseases,and the remodelling mode of atherosclerotic plaques is closely related to the occurrence of stroke.Positive remodelling(PR)is an outwards compensatory remodelling where the arterial wall grows outwards in an attempt to maintain a constant lumen diameter.For a long time,it was believed that the degree of stenosis can accurately reflect the risk of ischaemic stroke[3-5].Previous studies have revealed that lesions without significant luminal stenosis can also lead to acute events[6,7],as summarized in a recent meta-analysis study in which approximately 50%of acute/subacute ischaemic events were due to this type of lesion[6].Research[8,9]has pointed out that the PR of plaques is more dangerous and more likely to cause acute ischaemic stroke.Previous studies[10-13]have found that there are specific vascular remodelling phenomena in the coronary and carotid arteries of diabetic patients.However,due to the deep location and small lumen of intracranial arteries and limitations of imaging techniques,the relationship between intracranial arterial remodelling and diabetes is still unclear.In recent years,with the development of magnetic resonance technology and the emergence of high-resolution(HR)vascular wall imaging,a clear and multidimensional display of the intracranial vascular wall has been achieved.Therefore,in this study,HR wall imaging(HR-VWI)was used to display the remodelling characteristics of bilateral middle cerebral arteries and basilar arteries and to explore the factors of intracranial vascular remodelling and its relationship with diabetes.
文摘Amblyopia is the most common cause of vision loss in children and can persist into adulthood in the absence of effective intervention.Previous clinical and neuroimaging studies have suggested that the neural mechanisms underlying strabismic amblyopia and anisometropic amblyopia may be different.Therefore,we performed a systematic review of magnetic resonance imaging studies investigating brain alterations in patients with these two subtypes of amblyopia;this study is registered with PROSPERO(registration ID:CRD42022349191).We searched three online databases(PubMed,EMBASE,and Web of Science) from inception to April 1,2022;39 studies with 633 patients(324patients with anisometropic amblyo pia and 309 patients with strabismic amblyopia) and 580 healthy controls met the inclusion criteria(e.g.,case-control designed,pee r-reviewed articles) and were included in this review.These studies highlighted that both strabismic amblyopia and anisometropic amblyopia patients showed reduced activation and distorted topological cortical activated maps in the striate and extrastriate co rtices during tas k-based functional magnetic resonance imaging with spatial-frequency stimulus and retinotopic representations,respectively;these may have arisen from abnormal visual experiences.Compensations for amblyopia that are reflected in enhanced spontaneous brain function have been reported in the early visual cortices in the resting state,as well as reduced functional connectivity in the dorsal pathway and structural connections in the ventral pathway in both anisometro pic amblyopia and strabismic amblyopia patients.The shared dysfunction of anisometro pic amblyopia and strabismic amblyopia patients,relative to controls,is also chara cterized by reduced spontaneous brain activity in the oculomotor co rtex,mainly involving the frontal and parietal eye fields and the cerebellu m;this may underlie the neural mechanisms of fixation instability and anomalous saccades in amblyopia.With regards to specific alterations of the two forms of amblyo pia,anisometropic amblyo pia patients suffer more microstructural impairments in the precortical pathway than strabismic amblyopia patients,as reflected by diffusion tensor imaging,and more significant dysfunction and structural loss in the ventral pathway.Strabismic amblyopia patients experience more attenuation of activation in the extrastriate co rtex than in the striate cortex when compared to anisometropic amblyopia patients.Finally,brain structural magnetic resonance imaging alterations tend to be lateralized in the adult anisometropic amblyopia patients,and the patterns of brain alterations are more limited in amblyopic adults than in childre n.In conclusion,magnetic resonance imaging studies provide important insights into the brain alterations underlying the pathophysiology of amblyopia and demonstrate common and specific alte rations in anisometropic amblyo pia and strabismic amblyopia patients;these alterations may improve our understanding of the neural mechanisms underlying amblyopia.
基金Project supported by the National Natural Science Foundation of China(Grant No.61271079)the Vice Chancellor Research Grant in University of Wollongongthe Priority Academic Program Development of Jiangsu Higher Education Institutions,China
文摘Applications of multifractal analysis to white matter structure changes on magnetic resonance imaging(MRI) have recently received increasing attentions. Although some progresses have been made, there is no evident study on applying multifractal analysis to evaluate the white matter structural changes on MRI for Alzheimer's disease(AD) research. In this paper, to explore multifractal analysis of white matter structural changes on 3D MRI volumes between normal aging and early AD, we not only extend the traditional box-counting multifractal analysis(BCMA) into the 3D case, but also propose a modified integer ratio based BCMA(IRBCMA) algorithm to compensate for the rigid division rule in BCMA. We verify multifractal characteristics in 3D white matter MRI volumes. In addition to the previously well studied multifractal feature,△α, we also demonstrated △ f as an alternative and effective multifractal feature to distinguish NC from AD subjects.Both △α and △ f are found to have strong positive correlation with the clinical MMSE scores with statistical significance.Moreover, the proposed IRBCMA can be an alternative and more accurate algorithm for 3D volume analysis. Our findings highlight the potential usefulness of multifractal analysis, which may contribute to clarify some aspects of the etiology of AD through detection of structural changes in white matter.
基金Supported by The Young Talents Fund of the Second Hospital of Shandong University,No.2018YT16Rongxiang Regenerative Medicine Foundation of Shandong University,No.2019SDRX-09.
文摘BACKGROUND The main clinical manifestation of Alzheimer’s disease(AD)is memory loss,which can be accompanied by neuropsychiatric symptoms at different stages of the disease.Amygdala is closely related to emotion and memory.AIM To evaluate the diagnostic value of amygdala on structural magnetic resonance imaging(sMRI)for AD.METHODS In this study,22 patients with AD and 26 controls were enrolled.Their amygdala volumes were measured by sMRI and analyzed using an automatic analysis software.RESULTS The bilateral amygdala volumes of AD patients were significantly lower than those of the controls and were positively correlated with the hippocampal volumes.Receiver operating characteristic curve analyses showed that the sensitivity of the left and right amygdala volumes in diagnosing AD was 80.8%and 88.5%,respectively.Subgroup analyses showed that amygdala atrophy was more serious in AD patients with neuropsychiatric symptoms,which mainly included irritability(22.73%),sleep difficulties(22.73%),apathy(18.18%),and hallucination(13.64%).CONCLUSION Amygdala volumes measured by sMRI can be used to diagnose AD,and amygdala atrophy is more serious in patients with neuropsychiatric symptoms.
基金Supported by The Clinical Innovation Guidance Program of Hunan Provincial Science and Technology Department,China,No.2021SK51714The Hunan Nature Science Foundation,China,No.2023JJ30531.
文摘BACKGROUND Vertebral artery dissection(VAD)is a rare but life-threatening condition characterized by tearing of the intimal layer of the vertebral artery,leading to stenosis,occlusion or rupture.The clinical presentation of VAD can be heterogeneous,with common symptoms including headache,dizziness and balance problems.Timely diagnosis and treatment are crucial for favorable outcomes;however,VAD is often missed due to its variable clinical presentation and lack of robust diagnostic guidelines.High-resolution magnetic resonance imaging(HRMRI)has emerged as a reliable diagnostic tool for VAD,providing detailed visualization of vessel wall abnormalities.CASE SUMMARY A young male patient presented with an acute onset of severe headache,vomiting,and seizures,followed by altered consciousness.Imaging studies revealed bilateral VAD,basilar artery thrombosis,multiple brainstem and cerebellar infarcts,and subarachnoid hemorrhage.Digital subtraction angiography(DSA)revealed vertebral artery stenosis but failed to detect the dissection,potentially because intramural thrombosis obscured the VAD.In contrast,HRMRI confirmed the diagnosis by revealing specific signs of dissection.The patient was managed conservatively with antiplatelet therapy and other supportive measures,such as blood pressure control and pain management.After 5 mo of rehabilitation,the patient showed significant improvement in swallowing and limb strength.CONCLUSION HR-MRI can provide precise evidence for the identification of VAD.
基金This work was supported by the National Natural Science Foundation of China (No. 270274049) and subsidized by theSpecial Funds for Major State Basic Research Projects (G1999064800).
文摘Structures and crystal form transition of the novel aryl ether ketone polymer containing meta-phenylene linkage: PEKEKK(T/I) were investigated by wide angle X-ray diffraction (WAXD), imaging plates (IPs) and small angle X-ray scattering (SAXS). The energy of activation of the decomposition reaction and degree of crystallinity of PEKEKK(T/I) were determined by WAXD and thermo-gravimetric analysis (TGA), respectively. Results obtained from WAXD and IPs show that crystal forms coexist in the PEKEKK(T/I) samples isothermally cold crystallized in the temperature range from 180'C to 240T? and only form occurs in PEKEKK(TTI) samples isothermally cold crystallized at 2701C. The radius of gyration (Rg), thickness of microregions with electron-density fluctuations (E) and distribution of particle sizes were investigated by SAXS.
文摘AIM:To evaluate a high-resolution functional imaging device that yields quantitative data regarding macular blood flow and capillary network features in eyes with diabetic retinopathy(DR).METHODS:Prospective,cross-sectional comparative case-series in which blood flow velocities(BFVs)and noninvasive capillary perfusion maps(nCPMs)in macular vessels were measured in patients with DR and in healthy controls using the Retinal Functional Imager(RFI)device.RESULTS:A total of 27 eyes of 21 subjects were studied[9 eyes nonproliferative diabetic retinopathy(NPDR),9 eyes proliferative diabetic retinopathy(PDR)and 9 controls].All diabetic patients were type 2.All patients with NPDR and 5 eyes with PDR also had diabetic macular edema(DME).The NPDR group included eyes with severe(n=3)and moderate NPDR(n=6),and were symptomatic.A significant decrease in venular BFVs was observed in the macular region of PDR eyes when compared to controls(2.61±0.6 mm/s and 2.92±0.72 mm/s in PDR and controls,respectively,P=0.019)as well as PDR eyes with DME compared to NPDR eyes(2.36±0.51 mm/s and 2.94±1.09 mm/s in PDR with DME and NPDR,respectively,P=0.01).CONCLUSION:The RFI,a non-invasive imaging tool,provides high-resolution functional imaging of the retinal microvasculature and quantitative measurement of BFVs in visually impaired DR patients.The isolated diminish venular BFVs in PDR eyes compared to healthy eyes and PDR eyes with DME in comparison to NPDR eyes may indicate the possibility of more retinal vein compromise than suspected in advanced DR.
基金The project supported by Chinese National Science Foundation (Nos. 10335060, 10235010) and Creative Project Grants of ChineseAcademy of Science
文摘This paper describes the control software together with the operational hardware, which successfully realizes the operation of a new fully programmable imaging system with high spatial and temporal resolutions on the KT5D magnetic torus, for observing the visible l ight emission from the plasma discharge.
基金supported by the National Natural Science Foundation of China(Nos.21625501,21936001)the Beijing Outstanding Young Scientist Program(No.BJJWZYJH01201910005017).
文摘Single-cell imaging,a powerful analytical method to study single-cell behavior,such as gene expression and protein profiling,provides an essential basis for modern medical diagnosis.The coding and localization function of microfluidic chips has been developed and applied in living single-cell imaging in recent years.Simultaneously,chip-based living single-cell imaging is also limited by complicated trapping steps,low cell utilization,and difficult high-resolution imaging.To solve these problems,an ultra-thin temperature-controllable microwell array chip(UTCMA chip)was designed to develop a living single-cell workstation in this study for continuous on-chip culture and real-time high-resolution imaging of living single cells.The chip-based on ultra-thin ITO glass is highly matched with an inverted microscope(or confocal microscope)with a high magnification objective(100×oil lens),and the temperature of the chip can be controlled by combining it with a home-made temperature control device.High-throughput single-cell patterning is realized in one step when the microwell array on the chip uses hydrophilic glass as the substrate and hydrophobic SU-8 photoresist as the wall.The cell utilization rate,single-cell capture rate,and microwell occupancy rate are all close to 100%in the microwell array.This method will be useful in rare single-cell research,extending its application in the biological and medical-related fields,such as early diagnosis of disease,personalized therapy,and research-based on single-cell analysis.
基金supported by start-up funds from the laboratory of H.WFaculty Sponsored Student Research Awards(FSSRA)from the Department of Chemistry and Biochemistry in the College of Science and Mathematics at California State University,Fresno。
文摘In addition to the tens of millions of medical doses consumed annually around the world,a vast number of nuclear magnetic resonance imaging(MRI)contrast agents are being deployed in MRI research and development,offering precise diagnostic information,targeting capabilities,and analyte sensing.Superparamagnetic iron oxide nanoparticles(SPIONs)are notable among these agents,providing effective and versatile MRI applications while also being heavy-metal-free,bioconjugatable,and theranostic.We designed and implemented a novel two-pronged computational and experimental strategy to meet the demand for the efficient and rigorous development of SPION-based MRI agents.Our MATLAB-based modeling simulation and magnetic characterization revealed that extremely small maghemite SPIONs in the 1-3 nm range possess significantly reduced transversal relaxation rates(R_(2))and are therefore preferred for positive(T_(1)-weighted)MRI.Moreover,X-ray diffraction and X-ray absorption fine structure analyses demonstrated that the diffraction pattern and radial distribution function of our SPIONs matched those of the targeted maghemite crystals.In addition,simulations of the X-ray near-edge structure spectra indicated that our synthesized SPIONs,even at 1 nm,maintained a spherical structure.Furthermore,in vitro and in vivo MRI investigations showed that our 1-nm SPIONs effectively highlighted whole-body blood vessels and major organs in mice and could be cleared through the kidney route to minimize potential post-imaging side effects.Overall,our innovative approach enabled a swift discovery of the desired SPION structure,followed by targeted synthesis,synchrotron radiation spectroscopic studies,and MRI evaluations.The efficient and rigorous development of our high-performance SPIONs can set the stage for a computational and experimental platform for the development of future MRI agents.