期刊文献+
共找到123,493篇文章
< 1 2 250 >
每页显示 20 50 100
A novel logging method for detecting highly resistive formations in oil-based mud using high-frequency electrodes
1
作者 Kang-Kang Wu Lei Wang +1 位作者 Shao-Gui Deng Xue-Wen Kou 《Petroleum Science》 2025年第5期1946-1958,共13页
The oil-based mud(OBM) borehole measurement environment presents significant limitations on the application of existing electrical logging instruments in high-resistance formations. In this paper, we propose a novel l... The oil-based mud(OBM) borehole measurement environment presents significant limitations on the application of existing electrical logging instruments in high-resistance formations. In this paper, we propose a novel logging method for detection of high-resistance formations in OBM using highfrequency electrodes. The method addresses the issue of shallow depth of investigation(DOI) in existing electrical logging instruments, while simultaneously ensuring the vertical resolution. Based on the principle of current continuity, the total impedance of the loop is obtained by equating the measurement loop to the series form of a capacitively coupled circuit. and its validity is verified in a homogeneous formation model and a radial two-layer formation model with a mud standoff. Then, the instrument operating frequency and electrode system parameters were preferentially determined by numerical simulation, and the effect of mud gap on impedance measurement was investigated. Subsequently, the DOI of the instrument was investigated utilizing the pseudo-geometric factor defined by the real part of impedance. It was determined that the detection depth of the instrument is 8.74 cm, while the effective vertical resolution was not less than 2 cm. Finally, a focused high-frequency electrode-type instrument was designed by introducing a pair of focused electrodes, which effectively enhanced the DOI of the instrument and was successfully deployed in the Oklahoma formation model. The simulation results demonstrate that the novel method can achieve a detection depth of 17.40 cm in highly-resistive formations drilling with OBM, which is approximately twice the depth of detection of the existing oil-based mud microimager instruments. Furthermore, its effective vertical resolution remains at or above 2 cm,which is comparable to the resolution of the existing OBM electrical logging instrument. 展开更多
关键词 Oil-based mud Highly-resistive high-frequency electrode Bulking electrode Depth of investigation
原文传递
Evaluation of the Effectiveness, Accuracy, Specificity, and Sensitivity of High-Frequency Ultrasound in Differentiating Benign and Malignant Breast Micronodules
2
作者 Danhong Yan Weimin Li Hongtao Duan 《Journal of Clinical and Nursing Research》 2025年第9期370-376,共7页
Objective:To analyze the significance of high-frequency ultrasound in differentiating benign and malignant breast micronodules.Methods:Eighty-five patients with breast micronodules admitted for diagnosis between Octob... Objective:To analyze the significance of high-frequency ultrasound in differentiating benign and malignant breast micronodules.Methods:Eighty-five patients with breast micronodules admitted for diagnosis between October 2022 and October 2024 were selected for high-frequency ultrasound diagnosis.The diagnostic efficacy of high-frequency ultrasound was evaluated by comparing it with the results of surgical pathology.Results:High-frequency ultrasound detected 50 benign nodules,primarily breast fibroadenomas,and 35 malignant nodules,mainly breast ductal carcinoma in situ.Based on surgical pathology results,the diagnostic accuracy of high-frequency ultrasound was 96.47%,specificity was 97.96%,and sensitivity was 94.44%.In high-frequency ultrasound diagnosis,the proportion of grade III and IV blood flow in malignant nodules was higher than that in benign nodules,while the proportion of regular shape and clear margins was lower.The proportion of microcalcifications and posterior echo attenuation was higher in malignant nodules,and the resistance index(RI)and peak blood flow velocity were lower than those in benign nodules(P<0.05).Conclusion:High-frequency ultrasound can effectively differentiate benign and malignant breast micronodules,determine specific nodule types,and exhibits high diagnostic accuracy and sensitivity.Additionally,benign and malignant nodules can be differentiated based on the grading of blood flow signals,sonographic features,and blood flow velocity,providing reasonable guidance for subsequent treatment plans. 展开更多
关键词 high-frequency ultrasound Breast micronodules Differentiating benign and malignant ACCURACY Sensitivity
暂未订购
Study on the Characteristics of High-Frequency Electromagnetic Wave Detection in Goaf Areas along Coal Seam Boreholes
3
作者 Maolin Yang 《Journal of Environmental & Earth Sciences》 2025年第7期272-284,共13页
China has a long history of coal mining,among which open-pit coal mines have a large number of small coal mine goafs underground.The distribution,shape,structure and other characteristics of goafs are isolated and dis... China has a long history of coal mining,among which open-pit coal mines have a large number of small coal mine goafs underground.The distribution,shape,structure and other characteristics of goafs are isolated and discontinuous,and there is no definite geological law to follow,which seriously threatens the safety of coal mine production and personnel life.Conventional ground geophysical methods have low accuracy in detecting goaf areas affected by mechanical interference from open-pit mines,especially for waterless goaf areas,which cannot be detected by existing methods.This article proposes the use of high-frequency electromagnetic waves for goaf detection.The feasibility of using drilling radar to detect goaf was theoretically analyzed,and a goaf detection model was established.The response characteristics of different fillers in the goaf under different frequencies of high-frequency electromagnetic waves were simulated and analyzed.In a certain open-pit mine in Inner Mongolia,100MHz high-frequency electromagnetic waves were used to detect the goaf through directional drilling on the ground.After detection,excavation verification was carried out,and the location of one goaf detected was verified.The results of engineering practice show that the application of high-frequency electromagnetic waves in goaf detection expands the detection radius of boreholes,has the advantages of high efficiency and accuracy,and has important theoretical and practical significance. 展开更多
关键词 Underground Coal Mine GOAF high-frequency Electromagnetic Wave(HFEW) BOREHOLE
在线阅读 下载PDF
A review on high-frequency electromagnetic interference induced by power electronics in new electric power systems
4
作者 Yundong Hu Xing Lei +3 位作者 Xizhou Du Ting Ye Hongning Song Hao Li 《Global Energy Interconnection》 2025年第5期804-820,共17页
New electric power systems characterized by a high proportion of renewable energy and power electronics equipment face significant challenges due to high-frequency(HF)electromagnetic interference from the high-speed s... New electric power systems characterized by a high proportion of renewable energy and power electronics equipment face significant challenges due to high-frequency(HF)electromagnetic interference from the high-speed switching of power converters.To address this situation,this paper offers an in-depth review of HF interference problems and challenges originating from power electronic devices.First,the root cause of HF electromagnetic interference,i.e.,the resonant response of the parasitic parameters of the system to high-speed switching transients,is analyzed,and various scenarios of HF interference in power systems are highlighted.Next,the types of HF interference are summarized,with a focus on common-mode interference in grounding systems.This paper thoroughly reviews and compares various suppression methods for conducted HF interference.Finally,the challenges involved and suggestions for addressing emerging HF interference problems from the perspective of both power electronics equipment and power systems are discussed.This review aims to offer a structured understanding of HF interference problems and their suppression techniques for researchers and practitioners. 展开更多
关键词 New power system Power electronics Switching transients high-frequency interference Common-mode interference suppression
在线阅读 下载PDF
High-frequency enhanced ultrafast compressed active photography
5
作者 Yizhao Meng Yu Lu +5 位作者 Pengfei Zhang Yi Liu Fei Yin Lin Kai Qing Yang Feng Chen 《Opto-Electronic Advances》 2025年第1期32-43,共12页
Single-shot ultrafast compressed imaging(UCI)is an effective tool for studying ultrafast dynamics in physics,chemistry,or material science because of its excellent high frame rate and large frame number.However,the ra... Single-shot ultrafast compressed imaging(UCI)is an effective tool for studying ultrafast dynamics in physics,chemistry,or material science because of its excellent high frame rate and large frame number.However,the random code(Rcode)used in traditional UCI will lead to low-frequency noise covering high-frequency information due to its uneven sampling interval,which is a great challenge in the fidelity of large-frame reconstruction.Here,a high-frequency enhanced compressed active photography(H-CAP)is proposed.By uniformizing the sampling interval of R-code,H-CAP capture the ultrafast process with a random uniform sampling mode.This sampling mode makes the high-frequency sampling energy dominant,which greatly suppresses the low-frequency noise blurring caused by R-code and achieves high-frequency information of image enhanced.The superior dynamic performance and large-frame reconstruction ability of H-CAP are verified by imaging optical self-focusing effect and static object,respectively.We applied H-CAP to the spatial-temporal characterization of double-pulse induced silicon surface ablation dynamics,which is performed within 220 frames in a single-shot of 300 ps.H-CAP provides a high-fidelity imaging method for observing ultrafast unrepeatable dynamic processes with large frames. 展开更多
关键词 ultrafast compressed imaging high-frequency enhanced sampling spectral-temporal transform transient processes high-fidelity reconstruction
在线阅读 下载PDF
Effectiveness of High-Frequency Electrosurgical Knife Surgery Under Painless Digestive Endoscopy in Elderly Patients with Gastrointestinal Polyps
6
作者 Yumin Lu 《Proceedings of Anticancer Research》 2025年第1期14-20,共7页
Objective:To analyze the therapeutic effect of high-frequency electrosurgical knife surgery guided by painless digestive endoscopy(PDE)in elderly patients with gastrointestinal polyps(GP).Methods:A total of 100 elderl... Objective:To analyze the therapeutic effect of high-frequency electrosurgical knife surgery guided by painless digestive endoscopy(PDE)in elderly patients with gastrointestinal polyps(GP).Methods:A total of 100 elderly GP patients admitted between June 2021 and December 2022 were selected.Patients were randomly divided into two groups:the painless group(50 cases)underwent high-frequency electrosurgical knife surgery guided by PDE,while the conventional group(50 cases)underwent the same surgery guided by traditional digestive endoscopy(DE).The total treatment efficacy,perioperative indicators,gastrointestinal hormone levels,oxidative stress(OS)markers,and complication rates were compared between the two groups.Results:The total treatment efficacy in the painless group was higher than that in the conventional group,and perioperative indicators were superior in the painless group(P<0.05).One week after treatment,the gastrointestinal hormone levels and OS-related markers in the painless group were better than those in the conventional group(P<0.05).The complication rate in the painless group was lower than in the conventional group(P<0.05).Conclusion:High-frequency electrosurgical knife surgery guided by PDE improves the effectiveness of polyp removal in elderly GP patients and accelerates postoperative recovery.It also protects gastrointestinal function,reduces postoperative OS,and ensures higher surgical safety. 展开更多
关键词 Painless digestive endoscopy high-frequency electrosurgical knife surgery Elderly gastrointestinal polyps
暂未订购
High-frequency complex permeability calculation for metallic soft magnetic particles with easy magnetization plane in non-magnetic medium
7
作者 Liangrui Tan Donglin He +5 位作者 Zhibiao Xu Guowu Wang Shengyu Yang Shaoyong Leng Ruilong Li Tao Wang 《Chinese Physics B》 2025年第11期254-261,共8页
Soft magnetic composites made from metallic magnetic particles with an easy magnetization plane(referred to as easy-plane metallic soft magnetic composites(SMC))are considered ideal materials for the next generation o... Soft magnetic composites made from metallic magnetic particles with an easy magnetization plane(referred to as easy-plane metallic soft magnetic composites(SMC))are considered ideal materials for the next generation of power electronic devices.This advantage is attributed to their ability to maintain high permeability at elevated frequencies.Despite these advantages,a definitive mathematical model that connects the high-frequency magnetic properties(e.g.,effective permeability)of easy-plane metallic SMCs to the intrinsic properties of the particles is still lacking.In this work,a theoretical calculation model for the effective permeability of easy-plane metallic SMCs was formulated.This model was derived from a skin effect-corrected Landau-Lifshitz-Gilbert(LLG)equation and integrated with effective medium theory incorporating inter-particle interaction.To validate the model,we prepared samples of easy-plane Y_(2)Co_(17)particle/PU SMCs with varying particle sizes and volume fractions.The experimental results showed a strong agreement with the calculated values.This research offers critical theoretical backing for the design and optimization of soft magnetic materials intended for high-frequency applications. 展开更多
关键词 easy-plane material high-frequency soft magnetic composites complex permeability Landau-Lifshitz-Gilbert(LLG)equation
原文传递
Fault Distance EstimationMethod for DC Distribution Networks Based on Sparse Measurement of High-Frequency Electrical Quantities
8
作者 He Wang Shiqiang Li +1 位作者 Yiqi Liu Jing Bian 《Energy Engineering》 2025年第11期4497-4521,共25页
With the evolution of DC distribution networks from traditional radial topologies to more complex multi-branch structures,the number of measurement points supporting synchronous communication remains relatively limite... With the evolution of DC distribution networks from traditional radial topologies to more complex multi-branch structures,the number of measurement points supporting synchronous communication remains relatively limited.This poses challenges for conventional fault distance estimation methods,which are often tailored to simple topologies and are thus difficult to apply to large-scale,multi-node DC networks.To address this,a fault distance estimation method based on sparse measurement of high-frequency electrical quantities is proposed in this paper.First,a preliminary fault line identification model based on compressed sensing is constructed to effectively narrow the fault search range and improve localization efficiency.Then,leveraging the high-frequency impedance characteristics and the voltage-current relationship of electrical quantities,a fault distance estimation approach based on high-frequency measurements from both ends of a line is designed.This enables accurate distance estimation even when the measurement devices are not directly placed at both ends of the faulted line,overcoming the dependence on specific sensor placement inherent in traditional methods.Finally,to further enhance accuracy,an optimization model based on minimizing the high-frequency voltage error at the fault point is introduced to reduce estimation error.Simulation results demonstrate that the proposed method achieves a fault distance estimation error of less than 1%under normal conditions,and maintains good performance even under adverse scenarios. 展开更多
关键词 DC distribution network fault location compressed sensing fault distance estimation high-frequency electrical quantities
在线阅读 下载PDF
Double-ring high-frequency common-mode switching oscillation current sensor for inverter-fed machine winding insulation monitoring
9
作者 Lingqing Pan Xizhou Du +3 位作者 Xing Lei Ting Ye Dawei Xiang Hao Li 《Global Energy Interconnection》 EI CSCD 2024年第1期106-116,共11页
Insulation failure significantly contributes to the unpredictable shutdown of power equipment.Compared to the partial discharge and high-frequency(HF)injection methods,the HF common-mode(CM)leakage current method offe... Insulation failure significantly contributes to the unpredictable shutdown of power equipment.Compared to the partial discharge and high-frequency(HF)injection methods,the HF common-mode(CM)leakage current method offers a non-intrusive and highly sensitive alternative.However,the detection of HF CM currents is susceptible to interference from differential-mode(DM)currents,which exhibit high-amplitude and multifrequency components during normal operation.To address this challenge,this paper proposes a double-ring current sensor based on the principle of magnetic shielding for inverter-fed machine winding insulation monitoring.The inner ring harnesses the magnetic aggregation effect to isolate the DM current magnetic field,whereas the outer ring serves as the magnetic core of the Rogowski current sensor,enabling HF CM current monitoring.First,the magnetic field distributions of the CM and DM currents were analyzed.Then,a correlation between the sensor parameters and signal-to-noise ratio of the target HF CM current was established.Finally,an experimental study was conducted on a 3-kW PMSM for verification.The results indicate that the proposed double-ring HF CM sensor can effectively mitigate DM current interference.Compared to a single-ring sensor,a reduction of approximately 40%in the DM component was achieved,which significantly enhanced the precision of online insulation monitoring. 展开更多
关键词 Magnetic shielding Double-ring Common-mode current Maxwell simulation
在线阅读 下载PDF
The relationship between the high-frequency performance of supercapacitors and the type of doped nitrogen in the carbon electrode 被引量:4
10
作者 FAN Ya-feng YI Zong-lin +6 位作者 ZHOU Yi XIE Li-jing SUN Guo-hua WANG Zhen-bing Huang Xian-hong SU Fang-yuan CHEN Cheng-meng 《新型炭材料(中英文)》 SCIE EI CAS CSCD 北大核心 2024年第5期1015-1026,共12页
Nitrogen doping has been widely used to improve the performance of carbon electrodes in supercapacitors,particularly in terms of their high-frequency response.However,the charge storage and electrolyte ion response me... Nitrogen doping has been widely used to improve the performance of carbon electrodes in supercapacitors,particularly in terms of their high-frequency response.However,the charge storage and electrolyte ion response mechanisms of different nitrogen dopants at high frequencies are still unclear.In this study,melamine foam carbons with different configurations of surfacedoped N were formed by gradient carbonization,and the effects of the configurations on the high-frequency response behavior of the supercapacitors were analyzed.Using a combination of experiments and first-principle calculations,we found that pyrrolic N,characterized by a higher adsorption energy,increases the charge storage capacity of the electrode at high frequencies.On the other hand,graphitic N,with a lower adsorption energy,increases the speed of ion response.We propose the use of adsorption energy as a practical descriptor for electrode/electrolyte design in high-frequency applications,offering a more universal approach for improving the performance of N-doped carbon materials in supercapacitors. 展开更多
关键词 high-frequency supercapacitors Carbon electrodes Doped nitrogen species Adsorption energy DESCRIPTOR
在线阅读 下载PDF
Review of the Analysis and Suppression for High-frequency Oscillations of the Grid-connected Wind Power Generation System 被引量:2
11
作者 Bo Pang Qi Si +4 位作者 Pan Jiang Kai Liao Xiaojuan Zhu Jianwei Yang Zhengyou He 《CES Transactions on Electrical Machines and Systems》 EI CSCD 2024年第2期127-142,共16页
High-frequency oscillation(HFO)of gridconnected wind power generation systems(WPGS)is one of the most critical issues in recent years that threaten the safe access of WPGS to the grid.Ensuring the WPGS can damp HFO is... High-frequency oscillation(HFO)of gridconnected wind power generation systems(WPGS)is one of the most critical issues in recent years that threaten the safe access of WPGS to the grid.Ensuring the WPGS can damp HFO is becoming more and more vital for the development of wind power.The HFO phenomenon of wind turbines under different scenarios usually has different mechanisms.Hence,engineers need to acquire the working mechanisms of the different HFO damping technologies and select the appropriate one to ensure the effective implementation of oscillation damping in practical engineering.This paper introduces the general assumptions of WPGS when analyzing HFO,systematically summarizes the reasons for the occurrence of HFO in different scenarios,deeply analyses the key points and difficulties of HFO damping under different scenarios,and then compares the technical performances of various types of HFO suppression methods to provide adequate references for engineers in the application of technology.Finally,this paper discusses possible future research difficulties in the problem of HFO,as well as the possible future trends in the demand for HFO damping. 展开更多
关键词 Damping method high-frequency oscillation STABILITY Wind power generation
在线阅读 下载PDF
Therapeutic efficacy of methylprednisolone sodium succinate via diverse administration routes for mid-to high-frequency sudden sensorineural hearing loss 被引量:4
12
作者 Xiang-Da Meng Ting-Ting Li Li-Min Deng 《World Journal of Clinical Cases》 SCIE 2024年第18期3321-3331,共11页
BACKGROUND Sudden sensorineural hearing loss(SSNHL),characterized by a rapid and unexplained loss of hearing,particularly at moderate to high frequencies,presents a significant clinical challenge.The therapeutic use o... BACKGROUND Sudden sensorineural hearing loss(SSNHL),characterized by a rapid and unexplained loss of hearing,particularly at moderate to high frequencies,presents a significant clinical challenge.The therapeutic use of methylprednisolone sodium succinate(MPSS)via different administration routes,in combination with conventional medications,remains a topic of interest.AIM To compare the therapeutic efficacy of MPSS administered via different routes in combination with conventional drugs for the treatment of mid-to high-frequency SSNHL.METHODS The medical records of 109 patients with mid-to high-frequency SSNHL were analyzed.The patients were divided into three groups based on the route of administration:Group A[intratympanic(IT)injection of MPSS combined with mecobalamin and Ginkgo biloba leaf extract injection],Group B(intravenous injection of MPSS combined with mecobalamin and Ginkgo biloba leaf extract injection),and Group C(single IT injection of MPSS).The intervention effects were compared and analyzed.RESULTS The posttreatment auditory thresholds in Group A(21.23±3.34)were significantly lower than those in Groups B(28.52±3.36)and C(30.23±4.21;P<0.05).Group A also exhibited a significantly greater speech recognition rate(92.23±5.34)than Groups B and C.The disappearance time of tinnitus,time to hearing recovery,and disappearance time of vertigo in Group A were significantly shorter than those in Groups B and C(P<0.05).The total effective rate in Group A(97.56%)was significantly greater than that in Groups B and C(77.14%and 78.79%,χ^(2)=7.898,P=0.019).Moreover,the incidence of adverse reactions in Groups A and C was significantly lower than that in Group B(4.88%,3.03%vs 2.57%,χ^(2)=11.443,P=0.003),and the recurrence rate in Group A was significantly lower than that in Groups B and C(2.44%vs 20.00%vs 21.21%,χ^(2)=7.120,P=0.028).CONCLUSION IT injection of MPSS combined with conventional treatment demonstrates superior efficacy and safety compared to systemic administration via intravenous infusion and a single IT injection of MPSS.This approach effectively improves patients'hearing and reduces the risk of disease recurrence. 展开更多
关键词 Sudden loss of hearing at middle-and high-frequency of the descending type Methylprednisolone sodium succinate Intratympanic injection Intravenous injection
暂未订购
Kinematic deformation and intensity assessment of the 2021 Maduo M_(S)7.4 earthquake in Qinghai revealed by high-frequency GNSS
13
作者 Yu Li Yuebing Wang +2 位作者 Lijiang Zhao Hongbo Shi Pingping Wang 《Geodesy and Geodynamics》 EI CSCD 2024年第3期230-240,共11页
Rapid acquisition of the kinematic deformation field and seismic intensity distribution of large earthquakes is crucial for postseismic emergency rescue,disaster assessment,and future seismic risk research.The advance... Rapid acquisition of the kinematic deformation field and seismic intensity distribution of large earthquakes is crucial for postseismic emergency rescue,disaster assessment,and future seismic risk research.The advancement of GNSS observation and data processing makes it play an important role in this field,especially the high-frequency GNSS.We used the differential positioning method to calculate the 1 HZ GNSS data from 98 sites within 1000 km of the M_(S)7.4 Maduo earthquake epicenter.The kinematic deformation field and the distribution of the seismic intensity by using the peak ground velocity derived from displacement waveforms were obtained.The results show that:1)Horizontal coseismic response deformation levels ranging from 25 mm to 301 mm can be observed within a 1000 km radius from the epicenter.Coseismic response deformation on the east and west sides shows bilateral asymmetry,which markedly differs from the symmetry presented by surface rupture.2)The seismic intensity obtained through high-frequency GNSS and field investigations exhibits good consistency of the scope and orientation in the high seismic intensity area,although the former is generally slightly smaller than the latter.3)There may exist obstacles on the eastern side of the seismogenic fault.The Maduo earthquake induced a certain tectonic stress loading effect on the western Kunlun Pass-Jiangcuo fault(KPJF)and Maqin-Maqu segment,resulting in higher seismic risk in the future. 展开更多
关键词 Maduo earthquake high-frequency GNSS Kinematic deformation Seismic intensity
原文传递
Dynamic Response of Foundations during Startup of High-Frequency Tunnel Equipment
14
作者 Dawei Ruan Mingwei Hu 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第7期821-844,共24页
The specialized equipment utilized in long-line tunnel engineering is evolving towards large-scale,multifunctional,and complex orientations.The vibration caused by the high-frequency units during regular operation is ... The specialized equipment utilized in long-line tunnel engineering is evolving towards large-scale,multifunctional,and complex orientations.The vibration caused by the high-frequency units during regular operation is supported by the foundation of the units,and the magnitude of vibration and the operating frequency fluctuate in different engineering contexts,leading to variations in the dynamic response of the foundation.The high-frequency units yield significantly diverse outcomes under different startup conditions and times,resulting in failure to meet operational requirements,influencing the normal function of the tunnel,and causing harm to the foundation structure,personnel,and property in severe cases.This article formulates a finite element numerical computation model for solid elements using three-dimensional elastic body theory and integrates field measurements to substantiate and ascertain the crucial parameter configurations of the finite element model.By proposing a comprehensive startup timing function for high-frequency dynamic machines under different startup conditions,simulating the frequency andmagnitude variations during the startup process,and suggesting functions for changes in frequency and magnitude,a simulated startup schedule function for high-frequency machines is created through coupling.Taking into account the selection of the transient dynamic analysis step length,the dynamic response results for the lower dynamic foundation during its fundamental frequency crossing process are obtained.The validation checks if the structural magnitude surpasses the safety threshold during the critical phase of unit startup traversing the structural resonance region.The design recommendations for high-frequency units’dynamic foundations are provided,taking into account the startup process of the machine and ensuring the safe operation of the tunnel. 展开更多
关键词 Tunnel equipment high-frequency units startup conditions transient dynamics dynamic response foundation design
在线阅读 下载PDF
Reduction of High-Frequency Core Loss of a Fe_(77.2)Si_(11)B_(8.5)Cu_(0.8)Nb_(2.5)Soft Magnetic Nanocrystalline Alloy by Minor Alloying
15
作者 Shushen Guo Yanhui Li +2 位作者 Yibing Zhang Lu Yang Wei Zhang 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 2024年第11期1984-1992,共9页
Enhancing saturation magnetic flux density(Bs)while reducing high-frequency core loss in Finemet-type nanocrystalline alloys is of great significance in achieving the miniaturization,high-frequency,and energy-saving o... Enhancing saturation magnetic flux density(Bs)while reducing high-frequency core loss in Finemet-type nanocrystalline alloys is of great significance in achieving the miniaturization,high-frequency,and energy-saving of modern power electronic devices.In this work,we first designed a high-Bs Fe_(77.2)Si_(11)B_(8.5)Cu_(0.8)Nb_(2.5)alloy by appropriately reducing the non-magnetic elements in typical Finemet nanocrystalline alloys,and subsequently alloyed 2 at%Co,Al,and Mo,respectively.The effects of alloying elements on structure and static and high-frequency magnetic properties were studied.The results reveal that,alloying Al or Mo reduces the averageα-Fe grain size(Dα-Fe)in the nanocrystalline alloys,while Co exhibits a slight influence.The added Al or Mo results in decreases in both the Bs and coercivity(Hc)of the nanocrystalline alloys,whereas Co increases the Bs without changing Hc,and meanwhile,all alloying elements show minimal effects on effective permeability(μe).Furthermore,the addition of Co,Al,or Mo lowers the core loss(Pcv)at 0.2 T/100 kHz of the based nanocrystalline alloy with reductions of 10.9%,29.6%,and 26.8%,respectively.A Fe_(75.2)Si_(11)B_(8.5)Cu_(0.8)Nb_(2.5)Al_(2)nanocrystalline alloy exhibits outstanding soft magnetic properties with Bs,Hc,μe at 10 kHz and 100 kHz,and Pcv at 0.2 T/100 kHz of 1.34 T,0.8 A/m,27,400,18,000,and 350 kW/m3,respectively.The reduction in Pcv is primarily attributed to the decreased eddy current losses,originating from the increased electrical resistivity by elements alloying. 展开更多
关键词 Fe-based nanocrystalline alloy Fe-Si-B-Cu-Nb alloy Soft magnetic property high-frequency loss Electrical resistivity
原文传递
Efficient activation of the Co/SBA-15catalyst by high-frequency AC-DBD plasma thermal effects for toluene removal
16
作者 李越 姜楠 +5 位作者 刘政妍 秦亮 彭邦发 王荣刚 孙玉荣 李杰 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第8期84-94,共11页
Dielectric barrier discharge(DBD)plasma excited by a high-frequency alternating-current(AC)power supply is widely employed for the degradation of volatile organic compounds(VOCs).However,the thermal effect generated d... Dielectric barrier discharge(DBD)plasma excited by a high-frequency alternating-current(AC)power supply is widely employed for the degradation of volatile organic compounds(VOCs).However,the thermal effect generated during the discharge process leads to energy waste and low energy utilization efficiency.In this work,an innovative DBD thermally-conducted catalysis(DBD-TCC)system,integrating high-frequency AC-DBD plasma and its generated thermal effects to activate the Co/SBA-15 catalyst,was employed for toluene removal.Specifically,Co/SBA-15 catalysts are closely positioned to the ground electrode of the plasma zone and can be heated and activated by the thermal effect when the voltage exceeds 10 k V.At12.4 k V,the temperature in the catalyst zone reached 261℃ in the DBD-TCC system,resulting in an increase in toluene degradation efficiency of 17%,CO_(2)selectivity of 21.2%,and energy efficiency of 27%,respectively,compared to the DBD system alone.In contrast,the DBD thermally-unconducted catalysis(DBD-TUC)system fails to enhance toluene degradation due to insufficient heat absorption and catalytic activation,highlighting the crucial role of AC-DBD generated heat in the activation of the catalyst.Furthermore,the degradation pathway and mechanism of toluene in the DBD-TCC system were hypothesized.This work is expected to provide an energy-efficient approach for high-frequency AC-DBD plasma removal of VOCs. 展开更多
关键词 high-frequency alternating-current power thermal effect dielectric barrier discharge toluene degradation Co/SBA-15 catalysts
在线阅读 下载PDF
Effects of unilateral superimposed high-frequency jet ventilation on porcine hemodynamics and gas exchange during one-lung flooding
17
作者 Thomas Lesser Frank Wolfram +1 位作者 Conny Braun Reiner Gottschall 《World Journal of Experimental Medicine》 2024年第1期88-99,共12页
BACKGROUND Superimposed high-frequency jet ventilation(SHFJV)is suitable for respiratory motion reduction and essential for effective lung tumor ablation.Fluid filling of the target lung wing one-lung flooding(OLF)is ... BACKGROUND Superimposed high-frequency jet ventilation(SHFJV)is suitable for respiratory motion reduction and essential for effective lung tumor ablation.Fluid filling of the target lung wing one-lung flooding(OLF)is necessary for therapeutic ultrasound applications.However,whether unilateral SHFJV allows adequate hemodynamics and gas exchange is unclear.AIM To compared SHFJV with pressure-controlled ventilation(PCV)during OLF by assessing hemodynamics and gas exchange in different animal positions.METHODS SHFJV or PCV was used alternatingly to ventilate the non-flooded lungs of the 12 anesthetized pigs during OLF.The animal positions were changed from left lateral position to supine position(SP)to right lateral position(RLP)every 30 min.In each position,ventilation was maintained for 15 min in both modalities.Hemodynamic variables and arterial blood gas levels were repeatedly measured.RESULTS Unilateral SHFJV led to lower carbon dioxide removal than PCV without abnormally elevated carbon dioxide levels.SHFJV slightly decreased oxygenation in SP and RLP compared with PCV;the lowest values of PaO_(2) and PaO_(2)/FiO_(2) ratio were found in SP[13.0;interquartile range(IQR):12.6-5.6 and 32.5(IQR:31.5-38.9)kPa].Conversely,during SHFJV,the shunt fraction was higher in all animal positions(highest in the RLP:0.30).CONCLUSION In porcine model,unilateral SHFJV may provide adequate ventilation in different animal positions during OLF.Lower oxygenation and CO_(2) removal rates compared to PCV did not lead to hypoxia or hypercapnia.SHFJV can be safely used for lung tumor ablation to minimize ventilation-induced lung motion. 展开更多
关键词 One-lung ventilation Unilateral superimposed high-frequency jet ventilation One-lung flooding
在线阅读 下载PDF
The use of high-frequency data in cryptocurrency research:a meta-review of literature with bibliometric analysis
18
作者 Muhammad Anas Syed Jawad Hussain Shahzad Larisa Yarovaya 《Financial Innovation》 2024年第1期1431-1461,共31页
As the crypto-asset ecosystem matures,the use of high-frequency data has become increasingly common in decentralized finance literature.Using bibliometric analysis,we characterize the existing cryptocurrency literatur... As the crypto-asset ecosystem matures,the use of high-frequency data has become increasingly common in decentralized finance literature.Using bibliometric analysis,we characterize the existing cryptocurrency literature that employs high-frequency data.We highlighted the most influential authors,articles,and journals based on 189 articles from the Scopus database from 2015 to 2022.This approach enables us to identify emerging trends and research hotspots with the aid of co-citation and cartographic analyses.It shows knowledge expansion through authors’collaboration in cryptocurrency research with co-authorship analysis.We identify four major streams of research:(i)return prediction and measurement of cryptocurrency volatility,(ii)(in)efficiency of cryptocurrencies,(iii)price dynamics and bubbles in cryptocurrencies,and(iv)the diversification,safe haven,and hedging properties of Bitcoin.We conclude that highly traded cryptocurrencies’investment features and economic outcomes are analyzed predominantly on a tick-by-tick basis.This study also provides recommendations for future studies. 展开更多
关键词 Cryptocurrencies high-frequency data Intra-day data Bibliometric analysis Network analysis Meta-literature review
在线阅读 下载PDF
Currents from relativistic laser-plasma interaction as a novel metrology for the system stability of high-repetition-rate laser secondary sources 被引量:1
19
作者 Michael Ehret Iuliana-Mariana Vladisavlevici +16 位作者 Philip Wykeham Bradford Jakub Cikhardt Evgeny Filippov Jose Luis Henares Rubén Hernández Martín Diego de Luis JoséAntonio Pérez-Hernández Pablo Vicente Tomas Burian Enrique García-García Juan Hernández Cruz Mendez Marta Olivar Ruíz Óscar Varela Maria Dolores Rodríguez Frías João Jorge Santos Giancarlo Gatti 《Matter and Radiation at Extremes》 2025年第2期24-34,共11页
This work demonstrates experimentally the close relation between return currents from relativistic laser-driven target polarization and the quality of the relativistic laser–plasma interaction for laser-driven second... This work demonstrates experimentally the close relation between return currents from relativistic laser-driven target polarization and the quality of the relativistic laser–plasma interaction for laser-driven secondary sources,taking as an example ion acceleration by target normal sheath acceleration.The Pearson linear correlation of maximum return current amplitude and proton spectrum cutoff energy is found to be in the range from~0.70 to 0.94.kA-scale return currents rise in all interaction schemes where targets of any kind are charged by escaping laser-accelerated relativistic electrons.Their precise measurement is demonstrated using an inductive scheme that allows operation at high repetition rates.Thus,return currents can be used as a metrological online tool for the optimization of many laser-driven secondary sources and for diagnosing their stability.In particular,in two parametric studies of laser-driven ion acceleration,we carry out a noninvasive online measurement of return currents in a tape target system irradiated by the 1 PW VEGA-3 laser at Centro de Láseres Pulsados:first the size of the irradiated area is varied at best compression of the laser pulse;second,the pulse duration is varied by means of induced group delay dispersion at best focus.This work paves the way to the development of feedback systems that operate at the high repetition rates of PW-class lasers. 展开更多
关键词 relativistic laser plasma interaction pearson linear correlation proton spectrum cutoff energy interaction schemes ion acceleration target normal sheath accelerationthe return current return currents
在线阅读 下载PDF
Integrated Equipment with Functions of Current Flow Control and Fault Isolation for Multiterminal DC Grids
20
作者 Shuo Zhang Guibin Zou 《Energy Engineering》 EI 2025年第1期85-99,共15页
The multi-terminal direct current(DC)grid has extinctive superiorities over the traditional alternating current system in integrating large-scale renewable energy.Both the DC circuit breaker(DCCB)and the current flow ... The multi-terminal direct current(DC)grid has extinctive superiorities over the traditional alternating current system in integrating large-scale renewable energy.Both the DC circuit breaker(DCCB)and the current flow controller(CFC)are demanded to ensure the multiterminal DC grid to operates reliably and flexibly.However,since the CFC and the DCCB are all based on fully controlled semiconductor switches(e.g.,insulated gate bipolar transistor,integrated gate commutated thyristor,etc.),their separation configuration in the multiterminal DC grid will lead to unaffordable implementation costs and conduction power losses.To solve these problems,integrated equipment with both current flow control and fault isolation abilities is proposed,which shares the expensive and duplicated components of CFCs and DCCBs among adjacent lines.In addition,the complicated coordination control of CFCs and DCCBs can be avoided by adopting the integrated equipment in themultiterminal DC grid.In order to examine the current flow control and fault isolation abilities of the integrated equipment,the simulation model of a specific meshed four-terminal DC grid is constructed in the PSCAD/EMTDC software.Finally,the comparison between the integrated equipment and the separate solution is presented a specific result or conclusion needs to be added to the abstract. 展开更多
关键词 Integrated equipment multiterminal direct current grid current flow control fault isolation
在线阅读 下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部