A novel and sensitive HPLC-UV method has been developed for the simultaneous determination of twelve major compounds in Longdan Xiegan Pill.The chemical profile of the twelve compounds,including geniposidic acid(1),...A novel and sensitive HPLC-UV method has been developed for the simultaneous determination of twelve major compounds in Longdan Xiegan Pill.The chemical profile of the twelve compounds,including geniposidic acid(1),geniposide(2),gentiopicroside(3),liquiritin(4),crocin(5),baicalin(6),wogonoside(7),baicalein(8),glycyrrhizic acid(9),wogonin(10),oroxylin A(11)and aristolochic acid A(12),was acquired using high-performance liquid chromatography-diode array detector coupled with an electrospray tandem mass spectrometer(HPLC-DAD-ESI-MS).The analysis was performed on a Dikma Platisil ODS C18 column(250 mm×4.6 mm,5 μm)with a gradient solvent system of acetonitrile-0.1% aqueous formic acid.The validation was carried out and the linearities(r〉0.9996),repeatability(RSD〈1.8%),intra-and inter-day precision(RSD〈1.3%),and recoveries(ranging from 96.6% to 103.4%)were acceptable.The limits of detection(LOD)of these compounds ranged from 0.29 to 4.17 ng.Aristolochic acid A,which is the toxic ingredient,was not detected in all the batches of Longdan Xiegan Pill.Furthermore,hierarchical cluster analysis was used to evaluate the variation of the herbal prescription.The proposed method is simple,effective and suitable for the quality control of this traditional Chinese medicine(TCM).展开更多
The qualitative characterization and quantitative analysis of five bioactive flavonoids in Salix bordensis Turcz. were achieved via reversed-phase high-performance liquid chromatography coupled with diode array detect...The qualitative characterization and quantitative analysis of five bioactive flavonoids in Salix bordensis Turcz. were achieved via reversed-phase high-performance liquid chromatography coupled with diode array detection and tandem mass spectrometry, by using an Agilent ZORBAX SB-C18 HPLC column with a gradient elution of 0.3% (v/v) formic acid in water and methanol as the mobile phase. The compounds in the mixture were clearly identified by comparing their HPLC-DAD ultraviolet spectra, retention times, and MS data with those of corresponding reference compounds. All calibration curves showed good linearity (r2 > 0.9998) within the test ranges. The LOD, LOQ, specificity, precision, and accuracy for the method were validated. The results demonstrated that this analytical approach is ideal for the determination of bioactive compounds, such as flavonoids, and that it constructed a basis for the comprehensive evaluation of the quality of Salix bordensis Turcz.展开更多
In this work, a smart strategy that combines three-way high performance liquid chromatography-diode array detection(HPLCDAD) data with second-order calibration method based on alternating trilinear decomposition(ATLD)...In this work, a smart strategy that combines three-way high performance liquid chromatography-diode array detection(HPLCDAD) data with second-order calibration method based on alternating trilinear decomposition(ATLD) algorithm was proposed for simultaneous determination of eleven non-steroidal anti-inflammatory drugs(NSAIDs) illegally added into Chinese patent drugs and health products. All target analytes were rapidly eluted out within 14.5 min under a simple gradient elution. With the aid of the prominent "second-order advantage" of the ATLD algorithm, three HPLC problems, i.e. peak overlaps, unknown interferences and baseline drift, could be mathematically calibrated, and pure signals of target analytes could be extracted out from heavy-interference but information-rich HPLC-DAD data. The average spiked recoveries for all target analytes were in the range of 95.9%–106.4% with standard deviations lower than 7.5%. Validation parameters including sensitivity(SEN), selectivity(SEL), limit of detection(LOD), limit of quantitation(LOQ) and precisions of intra-day and inter-day were calculated to validate the accuracy of the proposed method, quantitative results were further confirmed by the classic HPLC method, which proved that chemometrics-assisted HPLC-DAD analytical strategy was highly efficient, accurate and green for drug-abuse monitoring of NSAIDs in Chinese patent drugs and health products.展开更多
基金supported by program NCET Foundation,NSFC(30725045)the Special Program for New Drug Innovation of the Ministry of Science and Technology,China(2009ZX09311-001,2008ZX09101-Z-029)+1 种基金Shanghai Leading Academic Discipline Project(B906)by the Scientific Foundation of Shanghai,China(07DZ19728,09DZ1975700,09DZ1971500)
文摘A novel and sensitive HPLC-UV method has been developed for the simultaneous determination of twelve major compounds in Longdan Xiegan Pill.The chemical profile of the twelve compounds,including geniposidic acid(1),geniposide(2),gentiopicroside(3),liquiritin(4),crocin(5),baicalin(6),wogonoside(7),baicalein(8),glycyrrhizic acid(9),wogonin(10),oroxylin A(11)and aristolochic acid A(12),was acquired using high-performance liquid chromatography-diode array detector coupled with an electrospray tandem mass spectrometer(HPLC-DAD-ESI-MS).The analysis was performed on a Dikma Platisil ODS C18 column(250 mm×4.6 mm,5 μm)with a gradient solvent system of acetonitrile-0.1% aqueous formic acid.The validation was carried out and the linearities(r〉0.9996),repeatability(RSD〈1.8%),intra-and inter-day precision(RSD〈1.3%),and recoveries(ranging from 96.6% to 103.4%)were acceptable.The limits of detection(LOD)of these compounds ranged from 0.29 to 4.17 ng.Aristolochic acid A,which is the toxic ingredient,was not detected in all the batches of Longdan Xiegan Pill.Furthermore,hierarchical cluster analysis was used to evaluate the variation of the herbal prescription.The proposed method is simple,effective and suitable for the quality control of this traditional Chinese medicine(TCM).
文摘The qualitative characterization and quantitative analysis of five bioactive flavonoids in Salix bordensis Turcz. were achieved via reversed-phase high-performance liquid chromatography coupled with diode array detection and tandem mass spectrometry, by using an Agilent ZORBAX SB-C18 HPLC column with a gradient elution of 0.3% (v/v) formic acid in water and methanol as the mobile phase. The compounds in the mixture were clearly identified by comparing their HPLC-DAD ultraviolet spectra, retention times, and MS data with those of corresponding reference compounds. All calibration curves showed good linearity (r2 > 0.9998) within the test ranges. The LOD, LOQ, specificity, precision, and accuracy for the method were validated. The results demonstrated that this analytical approach is ideal for the determination of bioactive compounds, such as flavonoids, and that it constructed a basis for the comprehensive evaluation of the quality of Salix bordensis Turcz.
基金supported by the National Natural Science Foundation of China (21575039, 21775039, 21521063)
文摘In this work, a smart strategy that combines three-way high performance liquid chromatography-diode array detection(HPLCDAD) data with second-order calibration method based on alternating trilinear decomposition(ATLD) algorithm was proposed for simultaneous determination of eleven non-steroidal anti-inflammatory drugs(NSAIDs) illegally added into Chinese patent drugs and health products. All target analytes were rapidly eluted out within 14.5 min under a simple gradient elution. With the aid of the prominent "second-order advantage" of the ATLD algorithm, three HPLC problems, i.e. peak overlaps, unknown interferences and baseline drift, could be mathematically calibrated, and pure signals of target analytes could be extracted out from heavy-interference but information-rich HPLC-DAD data. The average spiked recoveries for all target analytes were in the range of 95.9%–106.4% with standard deviations lower than 7.5%. Validation parameters including sensitivity(SEN), selectivity(SEL), limit of detection(LOD), limit of quantitation(LOQ) and precisions of intra-day and inter-day were calculated to validate the accuracy of the proposed method, quantitative results were further confirmed by the classic HPLC method, which proved that chemometrics-assisted HPLC-DAD analytical strategy was highly efficient, accurate and green for drug-abuse monitoring of NSAIDs in Chinese patent drugs and health products.