The obvious grain refinement of the primary MnSb phase has been observed in the Mn-89.7 wt%Sb alloy directionally solidified under a high-gradient magnetic field.With the application of a high-gradient magnetic field,...The obvious grain refinement of the primary MnSb phase has been observed in the Mn-89.7 wt%Sb alloy directionally solidified under a high-gradient magnetic field.With the application of a high-gradient magnetic field,the morphology of the primary MnSb phase transformed from developed dendritic-like to equiaxed-like,and the grain size decreased by approximately 93%.Refinement of the primary MnSb phase can be attributed to the constituent supercooling in front of the solidification interface,which promoted nucleation of the primary MnSb phase.The constituent supercooling can be linked to the enrichment of the Mn solute induced by the magnetic force and the Lorentz force that drove Mn solute migration and suppressed convection.展开更多
The introduction of functionalized magnetizable particles for the purification of enzymes or for the multi-use of pre-immobilized biocatalysts offers a great potential for time and cost savings in biotechnological pro...The introduction of functionalized magnetizable particles for the purification of enzymes or for the multi-use of pre-immobilized biocatalysts offers a great potential for time and cost savings in biotechnological process design. The selective separation of the magnetizable particles is performed for example by a high-gradient magnetic separator. In this study FEM and CFD simulations of the magnetic field and the fluid flow field within a filter chamber of a magnetic separator were carried out, to find an optimal separator design. The motion of virtual magnetizable particles was calculated with a one-way coupled Lagrangian approach in order to test many geometric and parametric variations in reduced time. It was found that a flow homogenisator smoothed the fluid flow, so that the linear velocity became nearly equal over the cross section in the direction of flow. Furthermore the retention of magnetizable particles increases with a high total edge length within the filter matrix.展开更多
The introduction of functionalized magnetizable particles and high-gradient magnetic separation represents a time and money saving alternative to conventional purification and separation unit operations in the biotech...The introduction of functionalized magnetizable particles and high-gradient magnetic separation represents a time and money saving alternative to conventional purification and separation unit operations in the biotechnical sector. This technique has some advantages especially for the recycling of immobilized enzymes. A new magnetic filter with sight glasses was constructed and produced to study the performance of high-gradient magnetic separation at varied parameters. By optical analysis the buildup of a clogging was identified as the major parameter which affected the separation performance. For the cleaning procedure, a two-phase flow of water with highly dispersed air bubbles was tested which led to a nearly complete cleaning of the filter chamber.展开更多
基金supported by the National Key R&D Program of China(Grant No.2021YFB3501404)the fund of the State Key Laboratory of Solidification Processing in NWPU(Grant No.SKLSP202101).
文摘The obvious grain refinement of the primary MnSb phase has been observed in the Mn-89.7 wt%Sb alloy directionally solidified under a high-gradient magnetic field.With the application of a high-gradient magnetic field,the morphology of the primary MnSb phase transformed from developed dendritic-like to equiaxed-like,and the grain size decreased by approximately 93%.Refinement of the primary MnSb phase can be attributed to the constituent supercooling in front of the solidification interface,which promoted nucleation of the primary MnSb phase.The constituent supercooling can be linked to the enrichment of the Mn solute induced by the magnetic force and the Lorentz force that drove Mn solute migration and suppressed convection.
文摘The introduction of functionalized magnetizable particles for the purification of enzymes or for the multi-use of pre-immobilized biocatalysts offers a great potential for time and cost savings in biotechnological process design. The selective separation of the magnetizable particles is performed for example by a high-gradient magnetic separator. In this study FEM and CFD simulations of the magnetic field and the fluid flow field within a filter chamber of a magnetic separator were carried out, to find an optimal separator design. The motion of virtual magnetizable particles was calculated with a one-way coupled Lagrangian approach in order to test many geometric and parametric variations in reduced time. It was found that a flow homogenisator smoothed the fluid flow, so that the linear velocity became nearly equal over the cross section in the direction of flow. Furthermore the retention of magnetizable particles increases with a high total edge length within the filter matrix.
文摘The introduction of functionalized magnetizable particles and high-gradient magnetic separation represents a time and money saving alternative to conventional purification and separation unit operations in the biotechnical sector. This technique has some advantages especially for the recycling of immobilized enzymes. A new magnetic filter with sight glasses was constructed and produced to study the performance of high-gradient magnetic separation at varied parameters. By optical analysis the buildup of a clogging was identified as the major parameter which affected the separation performance. For the cleaning procedure, a two-phase flow of water with highly dispersed air bubbles was tested which led to a nearly complete cleaning of the filter chamber.