A high-performance liquid chromatography(HPLC)method has been developed using a CAPCELL PAK ADME(150 mm×4.6 mm,5μm)as analytical column and a gradient elution with 15 min using acetonitrile and 0.1%(in volume fr...A high-performance liquid chromatography(HPLC)method has been developed using a CAPCELL PAK ADME(150 mm×4.6 mm,5μm)as analytical column and a gradient elution with 15 min using acetonitrile and 0.1%(in volume fraction)phosphoric acid water(pH=2.2)as the mobile phase.Three active substances in cosmetics were quantitatively detected simultaneously at a detection wavelength of 265 nm.The linear ranges of β-nicotinamide mononucleotides,ergothioneine and nicotinamide are 10~200 mg/L,5~100 mg/L and 5~100 mg/L respectively and the detection limits of three components are 3.0 mg/L,1.5 mg/L and 1.5 mg/L respectively.The recovery rate is 97.1~104.9%,with RSD≤2.0%.The method was applied to quantitative analysis of five samples of cosmetics toner,lotion,cream,essence and gel and three samples of raw materials.The results showed that the results of β-nicotinamide mononucleotide and ergothioneine in five cosmetics were consistent with the product label,while nicotinamide was inconsistent with the label.The purity of the three raw material samples was 99.5%,99.7% and 100.8%respectively.This method offers high precision,accuracy and short analysis time,making it a reliable approach for studying three active ingredients in cosmetics and suitable for quality control of related functional ingredients.展开更多
[Objectives]To extract and purify perfluoroalkyl and polyfluoroalkyl substances(PFAS)from aquatic products and determine the optimal pretreatment conditions.[Methods]The QuEChERS method was employed for the extraction...[Objectives]To extract and purify perfluoroalkyl and polyfluoroalkyl substances(PFAS)from aquatic products and determine the optimal pretreatment conditions.[Methods]The QuEChERS method was employed for the extraction and purification of PFAS in aquatic products.The detection of PFAS was carried out using liquid chromatography-tandem mass spectrometry(LC-MS/MS)in ESI negative ion mode with multiple reaction monitoring(MRM),and quantification was performed using the external standard method.By optimizing instrument parameters such as ion source temperature,spray voltage,and collision energy,high selectivity and sensitivity of the detection were ensured.[Results]The established calibration curves for 28 PFAS compounds compounds,covering a range of 0.02 to 20 ng/mL,demonstrated excellent linearity.Spike recovery tests yielded limits of detection(LOD)between 0.02 and 0.5μg/kg for the 28 PFAS compounds compounds,with recovery rates ranging from 72.2%to 113.0%.[Conclusions]The method established in this study demonstrates excellent linearity,and is accurate,reliable,efficient,simple,and rapid.It possesses considerable practical applicability and can be used for the quality and risk assessment of 28 PFAS compounds compounds in aquatic products,indicating high practical utility.展开更多
Due to their biological and physiological importance,flavonoids receive considerable attention in the literature. Nowadays,high performance liquid chromatography(HPLC)is the most widely used analytical method.In thi...Due to their biological and physiological importance,flavonoids receive considerable attention in the literature. Nowadays,high performance liquid chromatography(HPLC)is the most widely used analytical method.In this review,we summarize the principle of the choice of HPLC column and mobile phase,discuss and compare the features of various detections such as UV,fluorescence detection,electrochemical detection,chemilummescence detection,UV-MS etc.Recent developments in HPLC including ultra-LC and miniaturization of LC(micro-LC,capillary-LC,and nano-LC),are also discussed.展开更多
The ginkgo terpenoids including bilobalide and ginkgolides are the main pharmaceutical components in the leaves or extracts of Ginkgo biloba L. In this paper, the analysis of bilobalide and ginkgolides in leaves of Gi...The ginkgo terpenoids including bilobalide and ginkgolides are the main pharmaceutical components in the leaves or extracts of Ginkgo biloba L. In this paper, the analysis of bilobalide and ginkgolides in leaves of Ginkgo biloba L. by high performance liquid chromatography (HPLC)-electrospray ionization (ESI)-mass spectrometry (MS) was carried out. The separation was performed on Inertsil ODS3 column with methanol-water (36:64) as mobile phase, with 1 mL·min -1 of flow rate at 35℃. Then the mass spectrum analysis was conducted by ZMD micromass electrospray ionization (ESI)-mass spectrometer (MS). The HPLC total ion chromatogram and selected ion chromatogram (with 325, 407, 423, 439 of m/z) of the sample and ESI-/MS mass spectra of the peaks in the chromatograms were obtained. So bilobalide, ginkgolide A, B, C and J in Ginkgo biloba L. leaves were identified. The method is easy and rapid, with a good accuracy.展开更多
To develop a sensitive high performance liquid chromatography (HPLC) assay for the determination of trans-resveratrol in mouse liver. The whole liver of a mouse was removed from the body, homogenated, and extracted ...To develop a sensitive high performance liquid chromatography (HPLC) assay for the determination of trans-resveratrol in mouse liver. The whole liver of a mouse was removed from the body, homogenated, and extracted by ethyl acetate. The organic layer was isolated and evaporated to dryness, the residue was reconstituted in 0.2 mL mobile phase for centrifugation, and 50 uL of the supernatant was injected into the/-IPLC instrument. The sample was separated on a Shimadzu ODS column (150 mm × 4.6 mm, 5 um) at 35 ℃ and detected by ultraviolet (UV) detector at the wavelength of 305 nm. The mobile phase consisted of methanol and 0.1 mol/L acetic acid (4:6, v/v) with the flow-rote at 1 mL/min. The limit of detection was 3.0 ng/g in liver homogenate with a signal/noise ratio of 3:1. The linear range of the calibration curve was 5.0-120.0 ng/g. The mean recoveries at the concentrations of 6, 10 and 80 ng/g were 102%, 96.0% and 91.5%, respectively. The RSDs for inter- and intra-day assays were less than 5%. Compared with other reported methods, this method was faster and more sensitive. It was also proved to be of good linearity, selectivity, accuracy and precision, and can be efficiently applied to the pharmacoldnetic study of trans-resveratrol in mouse liver.展开更多
Objective High performance liquid chromatography(HPLC)and liquid chromatography-mass spectrometry(LC/MS)methods were developed for the determination of ganciclovir and its related substances.Methods A Hypersil ODS2 co...Objective High performance liquid chromatography(HPLC)and liquid chromatography-mass spectrometry(LC/MS)methods were developed for the determination of ganciclovir and its related substances.Methods A Hypersil ODS2 column(4.6 mm×250 mm,5 μm)was used with a mobile phase of 0.02 M potassium dihydrogen phosphate buffer(pH 6.0)-methanol(92∶8)at a flow rate of 1.0 mL/min,and UV detector set at 254 nm was used for monitoring the eluents.Results The method was simple,rapid,selective and capable of separating all related substances at trace level with a detection limit of 0.04 μg/mL.It has been validated with respect to accuracy,precision,linearity,and limits of detection and quantification.The linearity range was 10.2-153.0 μg/mL with r=0.9998.The percentage recoveries ranged from 96.7% to 101.6%,and RSD was 1.24%-1.96%(n=5).Conclusion The method was found to be suitable not only for monitoring the reactions during the process development but also for quality control of ganciclovir.For identification of related substances,LC/MS was used.The mainly related substances of ganciclovir active pharmaceutical ingredients(API)were determined as guanine,(1,3-dioxolan-4-yl)methyl acetate,and diacetyl guanine.展开更多
Among pharmaceuticals and personal care products released into the aquatic environment, antibiotics are of particular concern, because of their ubiquity and health effects. Although scientists have recently paid more ...Among pharmaceuticals and personal care products released into the aquatic environment, antibiotics are of particular concern, because of their ubiquity and health effects. Although scientists have recently paid more attention to the threat of antibiotics to coastal ecosystems, researchers have often focused on relatively few antibiotics, because of the absence of suitable analytical methods. We have therefore developed a method for the rapid detection of 36 antibiotic residues in coastal waters, including tetracyclines (TCs), sulfanilamides (SAs), and quinolones (QLs). The method consists of solid-phase extraction (SPE) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis, using electrospray ionization (ESI) in positive mode. The SPE was performed with Oasis HLB and Oasis MCX cartridges. Chromatographic separation on a Cr8 column was achieved using a binary eluent containing methanol and water with 0.1% formic acid. Typical recoveries of the analytes ranged from 67.4% to 109.3% at a fortification level of 100 ng/L. The precision of the method, calculated as relative standard deviation (RSD), was below 14.6% for all the compounds. The limits of detection (LODs) varied from 0.45 pg to 7.97 pg. The method was applied to detemaine the target analytes in coastal waters of the Yellow Sea in Liaoning, China. Among the tested antibiotics, 31 were found in coastal 'waters, with their concentrations between the LOD and 212.5 ng/L. These data indicate that this method is valid for analysis of antibiotics in coastal waters. The study first reports such a large number of antibiotics along the Yellow Sea coast of Liaoning, and should facilitate future comprehensive evaluation of antibiotics in coastal ecosystems展开更多
A novel method for the determination of five carbamate pesticides (metolcarb, carbofuran, carbaryl, isoprocard and diethofencard) in water samples was developed by dispersive liquid-liquid microextraction (DLLME) ...A novel method for the determination of five carbamate pesticides (metolcarb, carbofuran, carbaryl, isoprocard and diethofencard) in water samples was developed by dispersive liquid-liquid microextraction (DLLME) coupled with high performance liquid chromatography-diode array detector (HPLC-DAD). Some experimental parameters that influence the extraction efficiency were studied and optimized to obtain the best extraction results. Under the optimum conditions for the method, the calibration curve was linear in the concentration range from 5 to 1000 ng mL^-1 for all the five carbamate pesticides, with the correlation coefficients (r^2) varying from 0.9984 to 0.9994. Good enrichment factors were achieved ranging from 80 to 177- fold, depending on the compound. The limits of detection (LODs) (S/N = 3) were ranged from 0.1 to 0.5 ng mL^-1. The method has been successfully applied to the analysis of the pesticide residues in environmental water samples.展开更多
A rapid and accurate high performance liquid chromatography tandem mass spectrometry(HPLS-MS) method was established for quantification of chlorpromazine in pork. The porcine samples were pretreated with acetonitril...A rapid and accurate high performance liquid chromatography tandem mass spectrometry(HPLS-MS) method was established for quantification of chlorpromazine in pork. The porcine samples were pretreated with acetonitrile to precipitate proteins and followed by extraction with tert--butyl methyl ether(TBME). The separation was performed on a 5 μm Agilent XDB--C18 column with gradient elution. The mobile phase A was 0.01 mol/L ammonium formate in water and mobile phase B was acetonitrile. The flow rate was at 0.8 mL/min. Quantification was performed on a triple-quadrupole tandem mass spectrometer using the multiple selected reaction monitoring(MRM) mode. Transition of m/z +319.1 to 58.1 was used for the quantification of chlorpromazine. The method was validated at the concentration range of 0.4040 μg/kg to 8.080 μg/kg for chlorpromazine with correlation coefficient of 0.9999. The spiked recoveries were more than 80.0% and the limit of detection(LOD) was 0.052 μg/kg. The developed method, which offers advantages of convenience, rapid, specificity and higher sensitivity, can be used for determination of chlorpromazine hydrochloride in porcine muscles.展开更多
AIM: To observe the effect of protocatechuic aldchyde on the proliferation of hepatic stellate cells (HSCs). METHODS: Liver fibrosis was induced in rats by carbon tetrachloride (CCh). Then normal and fibrotic dr...AIM: To observe the effect of protocatechuic aldchyde on the proliferation of hepatic stellate cells (HSCs). METHODS: Liver fibrosis was induced in rats by carbon tetrachloride (CCh). Then normal and fibrotic drug sera were extracted from rats. The effects of protocatechuic aldchyde, raw Radix Salvia miltiorrhiza and drug sera of Salvia miltiorrhiza on HSC growth were determined by CCKoS. The protocatechuic aldchyde was separated by high performance liquid chromatography (HPLC) in a AIItima C18 column (250 mm × 4.6 mm, 5 μm) with a mobile phase of acetonitrile-4% glacial acetic acid solution (gradient elution) at the wavelength of 281 nm. RESULTS: Protocatechuic aldchyde, raw Radix Salvia miltiorrhiza and drug sera of Salvia miltiorrhiza were found to have inhibitory effects on proliferation of rat HSCs. Raw Radix Salvia miltiorrhiza had a stronger inhibitory effect than the drug sera. The fibrotic drug sera showed a higher suppressive effect than the normal drug sera (P 〈 0.05). Protocatechuic aldchyde was found in crude materials of both Radix Salvia miltiorrhiza and its corresponding drug sera. The average recovery (n = 6) was 110.5% for raw Salvia miltiorrhiza Bge, 102% for normal drug sera and 105.2% for fibrotic drug sera. The relative standard devitation (RSD) was 0.37%, 1.96% and 1.51%, respectively (n=6). The contents of protocatechuic aldchyde were 0.22%, 0.15% and 0.19%, respectively (n = 6) (P〈 0.05). The RSD was 0.33%, 0.75% and 1.24% (n=6) for raw material of Radix Salvia miltiorrhiza, normal drug sera and fibrotic drug sera, respectively. The samples were stable for 6 d. CONCLUSION: Protocatechuic aldchyde can inhibit the growth of HSCs. HPLC is suitable for the determination of virtual bioactive components of Chinese herbal medicines in vitro.展开更多
Methods for determining nine low molecular weight organic acids in root exudates were developed by using reversed phase high performance liquid chromatography with UV (ultraviolet) detection at 214 nm. The mobile ph...Methods for determining nine low molecular weight organic acids in root exudates were developed by using reversed phase high performance liquid chromatography with UV (ultraviolet) detection at 214 nm. The mobile phase was 18 mmol L -1 kH 2PO 4 adjusted to pH 2.25 with phosphoric acid and the flow rate was 0.3 mL min -1 . The analytical column was a reversed phase silica based C 18 column (Shim pack CLC ODS). The root exudates were collected through submerging the whole root system into aerated deionized water for 2 hours. The filtered exudate solutions were concentrated to dryness by rotary evaporation at 40 °C, dissolved in 10 mL mobile phase. The chromatographic conditions of organic acid determination were analyzed. The results showed that there was a high selectivity and sensitivity in the organic acid determination by reversed phase high performance liquid chromatography. Coefficients of variation for organic acid determination were lower than 10% except lactic acid. The recoveries were consistently between 80.1% to 108.3%. Detection limits were approximately 0.05 to 4.5 mg L -1 for organic acids except succinic acid with the detection limit of 7.0 mg L -1 . Phosphorus deficiency may contribute to the release of organic acids in soybean root exudates especially malic, lactic and citric acids.展开更多
Objective To determine residual acrylamide in medical polyacrylamide hydrogel by high performance liquid chromatography tandem mass spectroscopy (HPLC-MS). Methods After 13C3 labeled acrylamide was added, the sample...Objective To determine residual acrylamide in medical polyacrylamide hydrogel by high performance liquid chromatography tandem mass spectroscopy (HPLC-MS). Methods After 13C3 labeled acrylamide was added, the sample was extracted with water and then cleaned up with ExtrelutTM 20. The polyacrylamide hydrogel sample and 20 clinical cases were analyzed by HPLC-MS/MS and isotope dilution quantifying technique in selected reaction monitoring (SRM) mode. Results Acrylamide was separated from polyacrylamide hydrogel. The concentration of acrylamide in polyacrylamide hydrogel ranged from 3.9×10^-9 to 3.1×10^- 8g/L in the 20 clinical cases. The peak area was favorable linear and the range was up to 3 000 μg/L. The recovery rate was 103.1% with a relative standard deviation (RSD) of 6.20%, when the mark level was 50 lag/L. Conelusion HPLC-MS is a rapid, accurate, and sensitive method for the determination of residual acrylamide in medical polyacrylamide hydrogel.展开更多
HPLC method for analysis of the flavonoids from ginkgo biloba extract (GBE) was studied. By suitable selection of columns. symmetrical chromatographic peaks were obtained without using acidic modifier in the mobile ph...HPLC method for analysis of the flavonoids from ginkgo biloba extract (GBE) was studied. By suitable selection of columns. symmetrical chromatographic peaks were obtained without using acidic modifier in the mobile phase, which can eliminate the time for cleaning the chromatographic system and simplify the analystic method for GBE Experimental conditions: column: Hypersil BDS C-18, 5mumx4x250 mm: column temperature: 35degreesC; mobile phase: 46% methanol-54% water; flow rate: 0.7 mL/min; detection wavelength: 360nm.展开更多
This study aimed to establish a rapid analytical method to determine antioxidants in essence. A simple,efficient and practical, vortex-assisted, cloud-point extraction(VACPE) procedure is proposed for extracting and...This study aimed to establish a rapid analytical method to determine antioxidants in essence. A simple,efficient and practical, vortex-assisted, cloud-point extraction(VACPE) procedure is proposed for extracting and pre-concentrating four different of synthetic phenolic antioxidants(SPAs), propyl gallate(PG), tert-butylhydroquinone(TBHQ), butylated hydroxyanisole(BHA), butylated hydroxytoluene(BHT) in essence prior to high performance liquid chromatography(HPLC) analysis. The non-ionic surfactant, fatty alcohol polyoxyethylene ether-9(AEO-9), was used as extractant and vortex-mixing was utilized to reduce extraction time and improve extraction efficiency. The effective parameters of the extraction process, such as volume of extraction solvent, pH, vortex-mixing time, equilibration temperature and time, were optimized. Under the optimum conditions, the linear range of PG, TBHQ,BHA and BHT was 8.0–800 ng/mL. All correlation coefficients of the calibration curves were higher than0.996 and relative standard deviations(RSD, n = 5) were 2.36%–5.46%. The proposed method was successfully applied to the extraction and determination of antioxidants in essence samples with satisfactory relative recoveries of 89.4%–103.5%. The results confirmed the SPAs of essence could be effectively monitored by this method and also established good reference criteria for essence.展开更多
Effects of column temperature and flow rate on separation of organic acids were studied by determining nine low-molecular-weight organic acids on reversed- phase C18 column, using high performance liquid chromatograph...Effects of column temperature and flow rate on separation of organic acids were studied by determining nine low-molecular-weight organic acids on reversed- phase C18 column, using high performance liquid chromatography (HPLC) with a wavelength of UV (ultraviolet) 214 urn and a mobile phase of 18 mmol L-1 KH2PO4 buffer solution (pH 2.1). The thermal stability of organic acids was determined by comparing the recoveries of organic acids in different temperature treatments. The relationships between column temperature, flow rate or solvent pH and retention time were analyzed. At low solvent pH, separation efficiency of organic acids was increased by raising the flow rate of the solvent because of lowering the retention time of organic acids. High column temperature was unfavorable for the separation of organic acids. The separating effect can be enhanced through reducing column temperature in organic acid determination due to increasing retention time. High thermal stability of organic acids with low concentrations was observed at temperature of 40 ℃-45℃. Sensitivity and separation effect of organic acid determination by HPLC were clearly improved by a combination of raising flow rate and lowering column temperature at low solvent pH.展开更多
A novel high performance liquid chromatography-chemiluminescence(HPLC-CL) method for investigation of in vitro metabolism of repaglinide in pig liver microsomes with microdialysis sampling technique was developed.Th...A novel high performance liquid chromatography-chemiluminescence(HPLC-CL) method for investigation of in vitro metabolism of repaglinide in pig liver microsomes with microdialysis sampling technique was developed.The chromatographic separation was performed on a Hypersil BDS-C18 column with an isocratic mobile phase consisting of methanol and 0.01 mol/L KH_2PO_4(pH 3.0)(volume ratio 75:25) at a flow rate of 1.0 mL/min.The detection was based on the chemiluminescence reaction of repaglinide with acidic potassium permanganate(KMnO_4) and tris(2,2'-bipyridyl)ruthenium(Ⅲ)(Ru(bpy)_3^(3+)),which was immobilized on the cationic ion-exchange resin for obtaining high sensitivity and reducing consumption of expensive reagent.展开更多
The most suitable bio-analytical method based on liquid liquid extraction has been developed and validated for quantification of Rasagiline in human plasma. Rasagiline-13C3 mesylate was used as an internal standard fo...The most suitable bio-analytical method based on liquid liquid extraction has been developed and validated for quantification of Rasagiline in human plasma. Rasagiline-13C3 mesylate was used as an internal standard for Rasagiline. Zorbax Eclipse Plus C18 (2.1 mm × 50 mm, 3.5 um) column provided chromatographic separation of analyte followed by detection with mass spectrometry. The method involved simple isocratic chromatographic condition and mass spectrometric detection in the positive ionization mode using an API-4000 system. The lotal run time was 3.0 min. The proposed method has been validated with the linear range of 5 12000 pg/mL for Rasagiline. The intra-run and inter-run precision values were within 1.3% 2.9% and 1.6% 2.2% respectively for Rasagiline. The overall recovery for Rasagiline and Rasagiline-13C3 mesylate analog was 96.9% and 96.7% respectively. This validated method was successfully applied to the bioequivalence and pharmacokinetic study of human volunteers under fasting condition.展开更多
Objective: To develop the representative fingerprint for the quality control of placenta polypeptide injection. Methods: The chromatographic separation was performed using a Phenomenex Gemini C18 column (250 mm 4.6 mm...Objective: To develop the representative fingerprint for the quality control of placenta polypeptide injection. Methods: The chromatographic separation was performed using a Phenomenex Gemini C18 column (250 mm 4.6 mm, 5 mm) maintained at 30 1C. 0.1% aqueous trifiuoroacetic acid (Solvent A) and acetonitrile contained 0.1% TFA (Solvent B) were used as mobile phase with a gradient elution. Detection wavelength was 280 nm with the sample injection volume of 50 mL; the fiow rate was 1.0 mL/min. The fingerprints of different samples were investigated by similarity analysis. Results: Nine peaks were identified as the characteristic common peaks. The similarities of the fingerprints of the 10 batches of samples were above 0.992. Conclusion: This method showed high precision and good repeatability, and provided the basis for the improvement of the quality control of placenta polypeptide injection.展开更多
To establish a method for determining five saponins(notoginsenoside R1, ginsenoside Rg1, ginsenoside Re, ginsenoside Rb1 and ammonium glycyrrhizinate) in Glycyrrhizae, Notoginseng and Ginseng, the high performance liq...To establish a method for determining five saponins(notoginsenoside R1, ginsenoside Rg1, ginsenoside Re, ginsenoside Rb1 and ammonium glycyrrhizinate) in Glycyrrhizae, Notoginseng and Ginseng, the high performance liquid chromatography with diode array detector(HPLC-DAD) method was applied to an Inertsil ODS-SP column(4.6 mm×250 mm, 5 μm) with a mobile phase consisting of acetonitrile-0.05% phosphoric acid in a gradient elution manner. The flow rate was 1.0 mL/min. The column temperature was 30 ℃ and the detection wavelengths were 203 nm and 237 nm, respectively. The linear ranges were 0.700,0—7.000,0 μg for R1(r=1.000,0), 0.751,1— 7.511,4 μg for Rg1(r=1.000,0), 0.677,2—6.771,6 μg for Re(r=1.000,0), 0.733,9—7.339,1 μg for Rb1(r= 1.000,0), and 0.540,0—5.399,8 μg for ammonium glycyrrhizinate(r=0.999,9), respectively. In addition, their average recoveries were 100.28%, 105.83%, 104.09%, 99.36% and 98.54%, respectively. The relative standard deviations(RSDs) of precision, reproducibility and recovery were all less than 1.5%. The results indicate that the method is simple, accurate and reproducible so that it can be used for the simultaneous determination of the five saponins in Chinese patent medicines containing the three kinds of herbs.展开更多
[Method] This study aimed to determine trace amount of polycyclic aromatic hydrocarbons(PAHs) in urban sewage by using solid-phase extraction(SPE) coupled with high performance liquid chromatograph(HPLC).[Method] From...[Method] This study aimed to determine trace amount of polycyclic aromatic hydrocarbons(PAHs) in urban sewage by using solid-phase extraction(SPE) coupled with high performance liquid chromatograph(HPLC).[Method] From the aspects of solid-phase extraction column,elution solvent,elution volume,elution speed and so forth,the test conditions of SPE-HPLC method were optimized,and trace amount of PAHs in urban sewage was determined.[Result] The optimized solid-phase extraction conditions were SUPELCLEAN LC-18 solid-phase extraction column,methylene dichloride as elution solvent,15 ml elution volume,2 ml/min elution speed,5 ml/min loading speed,1 000 ml water with 200 ml methanol loading volume.Under the optimized extraction conditions,the recovery was high,namely 76.3%-105.2%;relative standard deviation was 3.8%-6.0%,showing good precision;detection limit was low,only 0.000 8-0.048 0 μg/L.[Conclusion] This method is user-friendly,with high sensitivity and good precision,and suitable for continuous determination of a large volume of water samples.展开更多
文摘A high-performance liquid chromatography(HPLC)method has been developed using a CAPCELL PAK ADME(150 mm×4.6 mm,5μm)as analytical column and a gradient elution with 15 min using acetonitrile and 0.1%(in volume fraction)phosphoric acid water(pH=2.2)as the mobile phase.Three active substances in cosmetics were quantitatively detected simultaneously at a detection wavelength of 265 nm.The linear ranges of β-nicotinamide mononucleotides,ergothioneine and nicotinamide are 10~200 mg/L,5~100 mg/L and 5~100 mg/L respectively and the detection limits of three components are 3.0 mg/L,1.5 mg/L and 1.5 mg/L respectively.The recovery rate is 97.1~104.9%,with RSD≤2.0%.The method was applied to quantitative analysis of five samples of cosmetics toner,lotion,cream,essence and gel and three samples of raw materials.The results showed that the results of β-nicotinamide mononucleotide and ergothioneine in five cosmetics were consistent with the product label,while nicotinamide was inconsistent with the label.The purity of the three raw material samples was 99.5%,99.7% and 100.8%respectively.This method offers high precision,accuracy and short analysis time,making it a reliable approach for studying three active ingredients in cosmetics and suitable for quality control of related functional ingredients.
文摘[Objectives]To extract and purify perfluoroalkyl and polyfluoroalkyl substances(PFAS)from aquatic products and determine the optimal pretreatment conditions.[Methods]The QuEChERS method was employed for the extraction and purification of PFAS in aquatic products.The detection of PFAS was carried out using liquid chromatography-tandem mass spectrometry(LC-MS/MS)in ESI negative ion mode with multiple reaction monitoring(MRM),and quantification was performed using the external standard method.By optimizing instrument parameters such as ion source temperature,spray voltage,and collision energy,high selectivity and sensitivity of the detection were ensured.[Results]The established calibration curves for 28 PFAS compounds compounds,covering a range of 0.02 to 20 ng/mL,demonstrated excellent linearity.Spike recovery tests yielded limits of detection(LOD)between 0.02 and 0.5μg/kg for the 28 PFAS compounds compounds,with recovery rates ranging from 72.2%to 113.0%.[Conclusions]The method established in this study demonstrates excellent linearity,and is accurate,reliable,efficient,simple,and rapid.It possesses considerable practical applicability and can be used for the quality and risk assessment of 28 PFAS compounds compounds in aquatic products,indicating high practical utility.
基金Administration Bureau of Traditional Chinese Medicine(2007-2008)for Scientific Research Program of TCM (Grant No.HL07057)
文摘Due to their biological and physiological importance,flavonoids receive considerable attention in the literature. Nowadays,high performance liquid chromatography(HPLC)is the most widely used analytical method.In this review,we summarize the principle of the choice of HPLC column and mobile phase,discuss and compare the features of various detections such as UV,fluorescence detection,electrochemical detection,chemilummescence detection,UV-MS etc.Recent developments in HPLC including ultra-LC and miniaturization of LC(micro-LC,capillary-LC,and nano-LC),are also discussed.
文摘The ginkgo terpenoids including bilobalide and ginkgolides are the main pharmaceutical components in the leaves or extracts of Ginkgo biloba L. In this paper, the analysis of bilobalide and ginkgolides in leaves of Ginkgo biloba L. by high performance liquid chromatography (HPLC)-electrospray ionization (ESI)-mass spectrometry (MS) was carried out. The separation was performed on Inertsil ODS3 column with methanol-water (36:64) as mobile phase, with 1 mL·min -1 of flow rate at 35℃. Then the mass spectrum analysis was conducted by ZMD micromass electrospray ionization (ESI)-mass spectrometer (MS). The HPLC total ion chromatogram and selected ion chromatogram (with 325, 407, 423, 439 of m/z) of the sample and ESI-/MS mass spectra of the peaks in the chromatograms were obtained. So bilobalide, ginkgolide A, B, C and J in Ginkgo biloba L. leaves were identified. The method is easy and rapid, with a good accuracy.
基金Postdoctoral Scientific Research Station of Gansu Yasheng Groups.
文摘To develop a sensitive high performance liquid chromatography (HPLC) assay for the determination of trans-resveratrol in mouse liver. The whole liver of a mouse was removed from the body, homogenated, and extracted by ethyl acetate. The organic layer was isolated and evaporated to dryness, the residue was reconstituted in 0.2 mL mobile phase for centrifugation, and 50 uL of the supernatant was injected into the/-IPLC instrument. The sample was separated on a Shimadzu ODS column (150 mm × 4.6 mm, 5 um) at 35 ℃ and detected by ultraviolet (UV) detector at the wavelength of 305 nm. The mobile phase consisted of methanol and 0.1 mol/L acetic acid (4:6, v/v) with the flow-rote at 1 mL/min. The limit of detection was 3.0 ng/g in liver homogenate with a signal/noise ratio of 3:1. The linear range of the calibration curve was 5.0-120.0 ng/g. The mean recoveries at the concentrations of 6, 10 and 80 ng/g were 102%, 96.0% and 91.5%, respectively. The RSDs for inter- and intra-day assays were less than 5%. Compared with other reported methods, this method was faster and more sensitive. It was also proved to be of good linearity, selectivity, accuracy and precision, and can be efficiently applied to the pharmacoldnetic study of trans-resveratrol in mouse liver.
文摘Objective High performance liquid chromatography(HPLC)and liquid chromatography-mass spectrometry(LC/MS)methods were developed for the determination of ganciclovir and its related substances.Methods A Hypersil ODS2 column(4.6 mm×250 mm,5 μm)was used with a mobile phase of 0.02 M potassium dihydrogen phosphate buffer(pH 6.0)-methanol(92∶8)at a flow rate of 1.0 mL/min,and UV detector set at 254 nm was used for monitoring the eluents.Results The method was simple,rapid,selective and capable of separating all related substances at trace level with a detection limit of 0.04 μg/mL.It has been validated with respect to accuracy,precision,linearity,and limits of detection and quantification.The linearity range was 10.2-153.0 μg/mL with r=0.9998.The percentage recoveries ranged from 96.7% to 101.6%,and RSD was 1.24%-1.96%(n=5).Conclusion The method was found to be suitable not only for monitoring the reactions during the process development but also for quality control of ganciclovir.For identification of related substances,LC/MS was used.The mainly related substances of ganciclovir active pharmaceutical ingredients(API)were determined as guanine,(1,3-dioxolan-4-yl)methyl acetate,and diacetyl guanine.
基金Supported by Young Scientists Research Program (No. 2009507)the Key Laboratory of Marine Bioactive Substances and Modern Analytical Techniques (No. MBSMAT-2010-04),SOA of China
文摘Among pharmaceuticals and personal care products released into the aquatic environment, antibiotics are of particular concern, because of their ubiquity and health effects. Although scientists have recently paid more attention to the threat of antibiotics to coastal ecosystems, researchers have often focused on relatively few antibiotics, because of the absence of suitable analytical methods. We have therefore developed a method for the rapid detection of 36 antibiotic residues in coastal waters, including tetracyclines (TCs), sulfanilamides (SAs), and quinolones (QLs). The method consists of solid-phase extraction (SPE) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis, using electrospray ionization (ESI) in positive mode. The SPE was performed with Oasis HLB and Oasis MCX cartridges. Chromatographic separation on a Cr8 column was achieved using a binary eluent containing methanol and water with 0.1% formic acid. Typical recoveries of the analytes ranged from 67.4% to 109.3% at a fortification level of 100 ng/L. The precision of the method, calculated as relative standard deviation (RSD), was below 14.6% for all the compounds. The limits of detection (LODs) varied from 0.45 pg to 7.97 pg. The method was applied to detemaine the target analytes in coastal waters of the Yellow Sea in Liaoning, China. Among the tested antibiotics, 31 were found in coastal 'waters, with their concentrations between the LOD and 212.5 ng/L. These data indicate that this method is valid for analysis of antibiotics in coastal waters. The study first reports such a large number of antibiotics along the Yellow Sea coast of Liaoning, and should facilitate future comprehensive evaluation of antibiotics in coastal ecosystems
基金supported both by the Natural Science Foundations of Hebei(No.B2008000210)the Scientific Research Foundation of Agricultural University of Hebei.
文摘A novel method for the determination of five carbamate pesticides (metolcarb, carbofuran, carbaryl, isoprocard and diethofencard) in water samples was developed by dispersive liquid-liquid microextraction (DLLME) coupled with high performance liquid chromatography-diode array detector (HPLC-DAD). Some experimental parameters that influence the extraction efficiency were studied and optimized to obtain the best extraction results. Under the optimum conditions for the method, the calibration curve was linear in the concentration range from 5 to 1000 ng mL^-1 for all the five carbamate pesticides, with the correlation coefficients (r^2) varying from 0.9984 to 0.9994. Good enrichment factors were achieved ranging from 80 to 177- fold, depending on the compound. The limits of detection (LODs) (S/N = 3) were ranged from 0.1 to 0.5 ng mL^-1. The method has been successfully applied to the analysis of the pesticide residues in environmental water samples.
文摘A rapid and accurate high performance liquid chromatography tandem mass spectrometry(HPLS-MS) method was established for quantification of chlorpromazine in pork. The porcine samples were pretreated with acetonitrile to precipitate proteins and followed by extraction with tert--butyl methyl ether(TBME). The separation was performed on a 5 μm Agilent XDB--C18 column with gradient elution. The mobile phase A was 0.01 mol/L ammonium formate in water and mobile phase B was acetonitrile. The flow rate was at 0.8 mL/min. Quantification was performed on a triple-quadrupole tandem mass spectrometer using the multiple selected reaction monitoring(MRM) mode. Transition of m/z +319.1 to 58.1 was used for the quantification of chlorpromazine. The method was validated at the concentration range of 0.4040 μg/kg to 8.080 μg/kg for chlorpromazine with correlation coefficient of 0.9999. The spiked recoveries were more than 80.0% and the limit of detection(LOD) was 0.052 μg/kg. The developed method, which offers advantages of convenience, rapid, specificity and higher sensitivity, can be used for determination of chlorpromazine hydrochloride in porcine muscles.
文摘AIM: To observe the effect of protocatechuic aldchyde on the proliferation of hepatic stellate cells (HSCs). METHODS: Liver fibrosis was induced in rats by carbon tetrachloride (CCh). Then normal and fibrotic drug sera were extracted from rats. The effects of protocatechuic aldchyde, raw Radix Salvia miltiorrhiza and drug sera of Salvia miltiorrhiza on HSC growth were determined by CCKoS. The protocatechuic aldchyde was separated by high performance liquid chromatography (HPLC) in a AIItima C18 column (250 mm × 4.6 mm, 5 μm) with a mobile phase of acetonitrile-4% glacial acetic acid solution (gradient elution) at the wavelength of 281 nm. RESULTS: Protocatechuic aldchyde, raw Radix Salvia miltiorrhiza and drug sera of Salvia miltiorrhiza were found to have inhibitory effects on proliferation of rat HSCs. Raw Radix Salvia miltiorrhiza had a stronger inhibitory effect than the drug sera. The fibrotic drug sera showed a higher suppressive effect than the normal drug sera (P 〈 0.05). Protocatechuic aldchyde was found in crude materials of both Radix Salvia miltiorrhiza and its corresponding drug sera. The average recovery (n = 6) was 110.5% for raw Salvia miltiorrhiza Bge, 102% for normal drug sera and 105.2% for fibrotic drug sera. The relative standard devitation (RSD) was 0.37%, 1.96% and 1.51%, respectively (n=6). The contents of protocatechuic aldchyde were 0.22%, 0.15% and 0.19%, respectively (n = 6) (P〈 0.05). The RSD was 0.33%, 0.75% and 1.24% (n=6) for raw material of Radix Salvia miltiorrhiza, normal drug sera and fibrotic drug sera, respectively. The samples were stable for 6 d. CONCLUSION: Protocatechuic aldchyde can inhibit the growth of HSCs. HPLC is suitable for the determination of virtual bioactive components of Chinese herbal medicines in vitro.
文摘Methods for determining nine low molecular weight organic acids in root exudates were developed by using reversed phase high performance liquid chromatography with UV (ultraviolet) detection at 214 nm. The mobile phase was 18 mmol L -1 kH 2PO 4 adjusted to pH 2.25 with phosphoric acid and the flow rate was 0.3 mL min -1 . The analytical column was a reversed phase silica based C 18 column (Shim pack CLC ODS). The root exudates were collected through submerging the whole root system into aerated deionized water for 2 hours. The filtered exudate solutions were concentrated to dryness by rotary evaporation at 40 °C, dissolved in 10 mL mobile phase. The chromatographic conditions of organic acid determination were analyzed. The results showed that there was a high selectivity and sensitivity in the organic acid determination by reversed phase high performance liquid chromatography. Coefficients of variation for organic acid determination were lower than 10% except lactic acid. The recoveries were consistently between 80.1% to 108.3%. Detection limits were approximately 0.05 to 4.5 mg L -1 for organic acids except succinic acid with the detection limit of 7.0 mg L -1 . Phosphorus deficiency may contribute to the release of organic acids in soybean root exudates especially malic, lactic and citric acids.
文摘Objective To determine residual acrylamide in medical polyacrylamide hydrogel by high performance liquid chromatography tandem mass spectroscopy (HPLC-MS). Methods After 13C3 labeled acrylamide was added, the sample was extracted with water and then cleaned up with ExtrelutTM 20. The polyacrylamide hydrogel sample and 20 clinical cases were analyzed by HPLC-MS/MS and isotope dilution quantifying technique in selected reaction monitoring (SRM) mode. Results Acrylamide was separated from polyacrylamide hydrogel. The concentration of acrylamide in polyacrylamide hydrogel ranged from 3.9×10^-9 to 3.1×10^- 8g/L in the 20 clinical cases. The peak area was favorable linear and the range was up to 3 000 μg/L. The recovery rate was 103.1% with a relative standard deviation (RSD) of 6.20%, when the mark level was 50 lag/L. Conelusion HPLC-MS is a rapid, accurate, and sensitive method for the determination of residual acrylamide in medical polyacrylamide hydrogel.
文摘HPLC method for analysis of the flavonoids from ginkgo biloba extract (GBE) was studied. By suitable selection of columns. symmetrical chromatographic peaks were obtained without using acidic modifier in the mobile phase, which can eliminate the time for cleaning the chromatographic system and simplify the analystic method for GBE Experimental conditions: column: Hypersil BDS C-18, 5mumx4x250 mm: column temperature: 35degreesC; mobile phase: 46% methanol-54% water; flow rate: 0.7 mL/min; detection wavelength: 360nm.
基金supported by College of Life Science and Technology, Kunming University of Science and Technology
文摘This study aimed to establish a rapid analytical method to determine antioxidants in essence. A simple,efficient and practical, vortex-assisted, cloud-point extraction(VACPE) procedure is proposed for extracting and pre-concentrating four different of synthetic phenolic antioxidants(SPAs), propyl gallate(PG), tert-butylhydroquinone(TBHQ), butylated hydroxyanisole(BHA), butylated hydroxytoluene(BHT) in essence prior to high performance liquid chromatography(HPLC) analysis. The non-ionic surfactant, fatty alcohol polyoxyethylene ether-9(AEO-9), was used as extractant and vortex-mixing was utilized to reduce extraction time and improve extraction efficiency. The effective parameters of the extraction process, such as volume of extraction solvent, pH, vortex-mixing time, equilibration temperature and time, were optimized. Under the optimum conditions, the linear range of PG, TBHQ,BHA and BHT was 8.0–800 ng/mL. All correlation coefficients of the calibration curves were higher than0.996 and relative standard deviations(RSD, n = 5) were 2.36%–5.46%. The proposed method was successfully applied to the extraction and determination of antioxidants in essence samples with satisfactory relative recoveries of 89.4%–103.5%. The results confirmed the SPAs of essence could be effectively monitored by this method and also established good reference criteria for essence.
文摘Effects of column temperature and flow rate on separation of organic acids were studied by determining nine low-molecular-weight organic acids on reversed- phase C18 column, using high performance liquid chromatography (HPLC) with a wavelength of UV (ultraviolet) 214 urn and a mobile phase of 18 mmol L-1 KH2PO4 buffer solution (pH 2.1). The thermal stability of organic acids was determined by comparing the recoveries of organic acids in different temperature treatments. The relationships between column temperature, flow rate or solvent pH and retention time were analyzed. At low solvent pH, separation efficiency of organic acids was increased by raising the flow rate of the solvent because of lowering the retention time of organic acids. High column temperature was unfavorable for the separation of organic acids. The separating effect can be enhanced through reducing column temperature in organic acid determination due to increasing retention time. High thermal stability of organic acids with low concentrations was observed at temperature of 40 ℃-45℃. Sensitivity and separation effect of organic acid determination by HPLC were clearly improved by a combination of raising flow rate and lowering column temperature at low solvent pH.
基金supported financially by the Fundamental Research Funds for the Central Universities(No. GK20091004)
文摘A novel high performance liquid chromatography-chemiluminescence(HPLC-CL) method for investigation of in vitro metabolism of repaglinide in pig liver microsomes with microdialysis sampling technique was developed.The chromatographic separation was performed on a Hypersil BDS-C18 column with an isocratic mobile phase consisting of methanol and 0.01 mol/L KH_2PO_4(pH 3.0)(volume ratio 75:25) at a flow rate of 1.0 mL/min.The detection was based on the chemiluminescence reaction of repaglinide with acidic potassium permanganate(KMnO_4) and tris(2,2'-bipyridyl)ruthenium(Ⅲ)(Ru(bpy)_3^(3+)),which was immobilized on the cationic ion-exchange resin for obtaining high sensitivity and reducing consumption of expensive reagent.
文摘The most suitable bio-analytical method based on liquid liquid extraction has been developed and validated for quantification of Rasagiline in human plasma. Rasagiline-13C3 mesylate was used as an internal standard for Rasagiline. Zorbax Eclipse Plus C18 (2.1 mm × 50 mm, 3.5 um) column provided chromatographic separation of analyte followed by detection with mass spectrometry. The method involved simple isocratic chromatographic condition and mass spectrometric detection in the positive ionization mode using an API-4000 system. The lotal run time was 3.0 min. The proposed method has been validated with the linear range of 5 12000 pg/mL for Rasagiline. The intra-run and inter-run precision values were within 1.3% 2.9% and 1.6% 2.2% respectively for Rasagiline. The overall recovery for Rasagiline and Rasagiline-13C3 mesylate analog was 96.9% and 96.7% respectively. This validated method was successfully applied to the bioequivalence and pharmacokinetic study of human volunteers under fasting condition.
文摘Objective: To develop the representative fingerprint for the quality control of placenta polypeptide injection. Methods: The chromatographic separation was performed using a Phenomenex Gemini C18 column (250 mm 4.6 mm, 5 mm) maintained at 30 1C. 0.1% aqueous trifiuoroacetic acid (Solvent A) and acetonitrile contained 0.1% TFA (Solvent B) were used as mobile phase with a gradient elution. Detection wavelength was 280 nm with the sample injection volume of 50 mL; the fiow rate was 1.0 mL/min. The fingerprints of different samples were investigated by similarity analysis. Results: Nine peaks were identified as the characteristic common peaks. The similarities of the fingerprints of the 10 batches of samples were above 0.992. Conclusion: This method showed high precision and good repeatability, and provided the basis for the improvement of the quality control of placenta polypeptide injection.
基金Supported by Plan Issue of Shanghai Science &Technology Committee(No.13401901100)
文摘To establish a method for determining five saponins(notoginsenoside R1, ginsenoside Rg1, ginsenoside Re, ginsenoside Rb1 and ammonium glycyrrhizinate) in Glycyrrhizae, Notoginseng and Ginseng, the high performance liquid chromatography with diode array detector(HPLC-DAD) method was applied to an Inertsil ODS-SP column(4.6 mm×250 mm, 5 μm) with a mobile phase consisting of acetonitrile-0.05% phosphoric acid in a gradient elution manner. The flow rate was 1.0 mL/min. The column temperature was 30 ℃ and the detection wavelengths were 203 nm and 237 nm, respectively. The linear ranges were 0.700,0—7.000,0 μg for R1(r=1.000,0), 0.751,1— 7.511,4 μg for Rg1(r=1.000,0), 0.677,2—6.771,6 μg for Re(r=1.000,0), 0.733,9—7.339,1 μg for Rb1(r= 1.000,0), and 0.540,0—5.399,8 μg for ammonium glycyrrhizinate(r=0.999,9), respectively. In addition, their average recoveries were 100.28%, 105.83%, 104.09%, 99.36% and 98.54%, respectively. The relative standard deviations(RSDs) of precision, reproducibility and recovery were all less than 1.5%. The results indicate that the method is simple, accurate and reproducible so that it can be used for the simultaneous determination of the five saponins in Chinese patent medicines containing the three kinds of herbs.
基金Supported by National Science and Technology Key Project of Water Pollution Control and Management (2012ZX07209-003)
文摘[Method] This study aimed to determine trace amount of polycyclic aromatic hydrocarbons(PAHs) in urban sewage by using solid-phase extraction(SPE) coupled with high performance liquid chromatograph(HPLC).[Method] From the aspects of solid-phase extraction column,elution solvent,elution volume,elution speed and so forth,the test conditions of SPE-HPLC method were optimized,and trace amount of PAHs in urban sewage was determined.[Result] The optimized solid-phase extraction conditions were SUPELCLEAN LC-18 solid-phase extraction column,methylene dichloride as elution solvent,15 ml elution volume,2 ml/min elution speed,5 ml/min loading speed,1 000 ml water with 200 ml methanol loading volume.Under the optimized extraction conditions,the recovery was high,namely 76.3%-105.2%;relative standard deviation was 3.8%-6.0%,showing good precision;detection limit was low,only 0.000 8-0.048 0 μg/L.[Conclusion] This method is user-friendly,with high sensitivity and good precision,and suitable for continuous determination of a large volume of water samples.