This paper has observed linewidth narrowing of dark states in rubidium cell by using the Hanle configuration. The reduction of the coherent resonance width under the transition of ^87Rb Fg = 1 → Fe = 0 is observed an...This paper has observed linewidth narrowing of dark states in rubidium cell by using the Hanle configuration. The reduction of the coherent resonance width under the transition of ^87Rb Fg = 1 → Fe = 0 is observed and the qualitative explanation about its mechanism is presented. Multiple subnatural width dips are obtained with a linearly polarized laser beam for the transitions of ^87Rb Fg = 1→Fe = 0, 1, 2. The feature of negative and positive slope, namely dispersionlike feature, is observed in the transmitted light.展开更多
A method of the relaxation time measurement in a flowing sample, based on the comparison of the amplitudes of nuclear magnetic resonance(NMR) signals observed from the reference and tested flowing samples was represen...A method of the relaxation time measurement in a flowing sample, based on the comparison of the amplitudes of nuclear magnetic resonance(NMR) signals observed from the reference and tested flowing samples was represented. The inductive and optical methods of NMR signal detection in the flowing sample were compared.The levels of NMR signal(10000 Hz-1/2) and the Hanle magnetometers signal-to-noise ratio(3500 Hz-1/2) were calculated and the possibility of the NMR signal detection with the small-size Hanle magnetometer was demonstrated. Additionally, the absence of a magnet-analyzer and the ability to measure both longitudinal and transverse relaxation time with high accuracy was demonstrated.展开更多
文摘This paper has observed linewidth narrowing of dark states in rubidium cell by using the Hanle configuration. The reduction of the coherent resonance width under the transition of ^87Rb Fg = 1 → Fe = 0 is observed and the qualitative explanation about its mechanism is presented. Multiple subnatural width dips are obtained with a linearly polarized laser beam for the transitions of ^87Rb Fg = 1→Fe = 0, 1, 2. The feature of negative and positive slope, namely dispersionlike feature, is observed in the transmitted light.
文摘A method of the relaxation time measurement in a flowing sample, based on the comparison of the amplitudes of nuclear magnetic resonance(NMR) signals observed from the reference and tested flowing samples was represented. The inductive and optical methods of NMR signal detection in the flowing sample were compared.The levels of NMR signal(10000 Hz-1/2) and the Hanle magnetometers signal-to-noise ratio(3500 Hz-1/2) were calculated and the possibility of the NMR signal detection with the small-size Hanle magnetometer was demonstrated. Additionally, the absence of a magnet-analyzer and the ability to measure both longitudinal and transverse relaxation time with high accuracy was demonstrated.