A rapid pretreatment method of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in soil and analysis by high resolution gas chromatograph-high resolution mass spectrometry was present.The extraction and a...A rapid pretreatment method of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in soil and analysis by high resolution gas chromatograph-high resolution mass spectrometry was present.The extraction and alumina clean up of PCDD/Fs in soil was achieved by accelerated solvent extractor.Then the multi-layer silica-gel column was used for further clean up.The whole method has been evaluated on certified reference soil and farm soil.Accuracy and precision of this method was tested with satisfactory results.展开更多
Two new stationary phases : (Ⅰ) [bikis(2,6-di-O-pentyl-3-O-hex-6O-pentyl-3-O-methyl)-β-CD-polysiloxane] and (Ⅱ) [heptkis(2,6-di-O-methyl-3-O-hex-6-enyl)-β-CD-polysiloxane] were synthesized and successfully used fo...Two new stationary phases : (Ⅰ) [bikis(2,6-di-O-pentyl-3-O-hex-6O-pentyl-3-O-methyl)-β-CD-polysiloxane] and (Ⅱ) [heptkis(2,6-di-O-methyl-3-O-hex-6-enyl)-β-CD-polysiloxane] were synthesized and successfully used for GC separation of chiral isomers.The possess high column efficiency and exhibit fine chiral separation ability.展开更多
采用HRGC/HRMS和同位素稀释定量技术对样品中17种4~8个氯原子取代的二嗯英和呋喃(PCDDs/Fs)与12种共平面多氯联苯(PCBs)定量分析。样品经索式抽提、FMS Power Prep系统净化、浓缩,利用高分辨气相色谱/高分辨质谱联用仪的多离子检...采用HRGC/HRMS和同位素稀释定量技术对样品中17种4~8个氯原子取代的二嗯英和呋喃(PCDDs/Fs)与12种共平面多氯联苯(PCBs)定量分析。样品经索式抽提、FMS Power Prep系统净化、浓缩,利用高分辨气相色谱/高分辨质谱联用仪的多离子检测方式,同位素稀释技术对样品中的目标化合物进行定性和定量。该方法的检出限为pg/g水平。^13同位素内标回收率范围为47%~100%。对3个CRM鱼样中17个PCDDs/Fs和4个PCBs的检测值均在标准定值允许误差范围内。对5个不同的实际样品鱼进行测定表明,样品的回收率在48%~100%之间,回收率的相对标准偏差小于20%;对同一样品进行定量检测的精密度测试结果表明,17种PCDDs/Fs浓度的RSD低于16%,12种PCBs浓度的RSD低于11%。本方法定量分析重现性良好。展开更多
文摘A rapid pretreatment method of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in soil and analysis by high resolution gas chromatograph-high resolution mass spectrometry was present.The extraction and alumina clean up of PCDD/Fs in soil was achieved by accelerated solvent extractor.Then the multi-layer silica-gel column was used for further clean up.The whole method has been evaluated on certified reference soil and farm soil.Accuracy and precision of this method was tested with satisfactory results.
文摘Two new stationary phases : (Ⅰ) [bikis(2,6-di-O-pentyl-3-O-hex-6O-pentyl-3-O-methyl)-β-CD-polysiloxane] and (Ⅱ) [heptkis(2,6-di-O-methyl-3-O-hex-6-enyl)-β-CD-polysiloxane] were synthesized and successfully used for GC separation of chiral isomers.The possess high column efficiency and exhibit fine chiral separation ability.
文摘采用HRGC/HRMS和同位素稀释定量技术对样品中17种4~8个氯原子取代的二嗯英和呋喃(PCDDs/Fs)与12种共平面多氯联苯(PCBs)定量分析。样品经索式抽提、FMS Power Prep系统净化、浓缩,利用高分辨气相色谱/高分辨质谱联用仪的多离子检测方式,同位素稀释技术对样品中的目标化合物进行定性和定量。该方法的检出限为pg/g水平。^13同位素内标回收率范围为47%~100%。对3个CRM鱼样中17个PCDDs/Fs和4个PCBs的检测值均在标准定值允许误差范围内。对5个不同的实际样品鱼进行测定表明,样品的回收率在48%~100%之间,回收率的相对标准偏差小于20%;对同一样品进行定量检测的精密度测试结果表明,17种PCDDs/Fs浓度的RSD低于16%,12种PCBs浓度的RSD低于11%。本方法定量分析重现性良好。