Luminal acidification in the epididymis is an important process for the regulation of male fertility. Low pH and low bicarbonate concentration are among key factors that keep spermatozoa in a dormant state while they ...Luminal acidification in the epididymis is an important process for the regulation of male fertility. Low pH and low bicarbonate concentration are among key factors that keep spermatozoa in a dormant state while they mature and are stored in this organ. Although significant bicarbonate reabsorption is achieved by principal cells in the proximal regions of the epididymis, clear and narrow cells are specialized for net proton secretion. Clear cells express very high levels of the vacuolar proton pumping ATPase (V-ATPase) in their apical membrane and are responsible for the bulk of proton secretion. In the present paper, selected aspects of V-ATPase regulation in clear cells are described and potential pathologies associated with mutations of some of the V-ATPase subunits are discussed. (Asian J Androl 2007 July; 9: 476-482)展开更多
AIM To compare the outcomes between laparoscopic Nissen fundoplication(LNF)and proton pump inhibitors(PPIs)therapy in patients with laryngopharyngeal reflux(LPR)and typeⅠhiatal hernia diagnosed by oropharyngeal p H-m...AIM To compare the outcomes between laparoscopic Nissen fundoplication(LNF)and proton pump inhibitors(PPIs)therapy in patients with laryngopharyngeal reflux(LPR)and typeⅠhiatal hernia diagnosed by oropharyngeal p H-monitoring and symptom-scale assessment.METHODS From February 2014 to January 2015,70 patients who were diagnosed with LPR and type I hiatal hernia and referred for symptomatic assessment,oropharyngeal p H-monitoring,manometry,and gastrointestinal endoscopy were enrolled in this study.All of the patients met the inclusion criteria.All of the patients underwent LNF or PPIs administration,and completed a2-year follow-up.Patients’baseline characteristics and primary outcome measures,including comprehensive and single symptoms of LPR,PPIs independence,and satisfaction,and postoperative complications were assessed.The outcomes of LNF and PPIs therapy were analyzed and compared. RESULTS There were 31 patients in the LNF group and 39patients in the PPI group.Fifty-three patients(25 in the LNF group and 28 in the PPI group)completed reviews and follow-up.Oropharyngeal p H-monitoring parameters were all abnormal with high acid exposure,a large amount of reflux,and a high Ryan score,associated reflux symptom index(RSI)score.There was a significant improvement in the RSI and LPR symptom scores after the 2-year follow-up in both groups(P<0.05),as well as typical symptoms of gastroesophageal reflux disease.Improvement in the RSI(P<0.005)and symptom scores of cough(P=0.032),mucus(P=0.011),and throat clearing(P=0.022)was significantly superior in the LNF group to that in the PPI group.After LNF and PPIs therapy,13 and 53 patients achieved independence from PPIs therapy(LNF:44.0%vs PPI:7.14%,P<0.001)during follow-up,respectively.Patients in the LNF group were more satisfied with their quality of life than those in the PPI group(LNF:62.49±28.68 vs PPI:44.36±32.77,P=0.004).Body mass index was significantly lower in the LNF group than in the PPI group(LNF:22.2±3.1kg/m^2 vs PPI:25.1±2.9 kg/m^2,P=0.001).CONCLUSION Diagnosis of LPR should be assessed with oropharyngeal p H-monitoring,manometry,and the symptom-scale.LNF achieves better improvement than PPIs for LPR with type I hiatal hernia.展开更多
Recovering waste heat from industrial processes is bene ficial in order to reduce the primary energy demands and heat pumps can be used to this purpose.Absorption heat pumps are energy-saving and environment-friendly ...Recovering waste heat from industrial processes is bene ficial in order to reduce the primary energy demands and heat pumps can be used to this purpose.Absorption heat pumps are energy-saving and environment-friendly because use working fluids that do not cause ozone depletion and can reduce the global warming emissions.The hybrid heat pump processes combine the conventional vapor-compression and the absorption heat pump cycles.Studies about the simulations and modeling of hybrid heat pumps are few in literature.In this research a mathematical model for single effect absorption and hybrid heat pump is carried out with Chem Cad? 6.0.1.LiBr–H_2O is used as working fluid while electrolytic NRTL and electrolytes latent heat are used as thermodynamic model due to the better results.Binary parameters of activity coef ficients are regressed from experimental vapor pressure data while default constants are used for the solubility expressions.A design of heat pumps is developed and a new modeling of generator is analyzed.The coef ficient of performance of absorption heat pump and hybrid heat pump is equal to 0.7 and 0.83 respectively.For absorption heat pump a sensitivity analysis is carried out to evaluate the effect of temperature and pressure generator,the concentration of Li–Br solution on coef ficient of performance,cooling capacity and working fluid temperature.For hybrid heat pump,the different coef ficients of performance,the primary energy ratio,the generator heat,and the compressor power are analyzed for different values of compressor proportion.Results show that comparing the two systems the hybrid pump allows to save more primary energy,costs and carbon dioxide emissions with respect to absorption heat pump with the increasing of compressor proportion parameter.Future researches should focus on the construction of this heat pumps integrated in chemical processes as a biogas plant or trigeneration systems.展开更多
The time domain guideposts requirements of a pump-motor system is transfered into a series of constraints which express the robust performance upper bound and regional poles limits of the closed loop system. Then the ...The time domain guideposts requirements of a pump-motor system is transfered into a series of constraints which express the robust performance upper bound and regional poles limits of the closed loop system. Then the servo system control problem is transferred into the problem of robust performance optimizing under regional poles constrains described by linear matrix inequality (LMI). These LMIs are easy to solve through the Matlab LMI-toolbox. Simulations indicate that the controller has excellent dynamic, static and disturbance rejection performance, and the control system is robust and has perfect H2 performance to the bounded external torque disturbance.展开更多
We herein evaluate the use of a chemical heat pump (CHP) for upgrading waste heat. CaCl<sub>2</sub> was used in the system of CHP. We evaluated the heat storage and heat releasing of CHP, and confirmed the...We herein evaluate the use of a chemical heat pump (CHP) for upgrading waste heat. CaCl<sub>2</sub> was used in the system of CHP. We evaluated the heat storage and heat releasing of CHP, and confirmed the practicality from the experimental results. The reactor module employed was an aluminum plate-tube heat exchanger with corrugated fins, and the CaCl<sub>2</sub> powder was in the form of a packed bed. Heat storage operation and heat dissipation operation are performed at the same time and supplied to the heat demand destination. At this time, an environmental heat source can be used during the heat radiation operation, and the heat output can release more heat than the heat input during heat storage. The heat discharging and charging characteristics of the reactor module were evaluated experimentally. The coefficient of performance (COP) was calculated for the heat upgrading cycle, and the heat output in the system was determined. A COP of 1.42 and output of 650 W/L, based on the heat exchanger volume, were obtained using a 600 s change time for the heat pump.展开更多
In this paper, we propose a H∞ robust observer-based control DC motor based on a photovoltaic pumping system. Maximum power point tracking is achieved via an algorithm using Perturb and Observe method, with array vol...In this paper, we propose a H∞ robust observer-based control DC motor based on a photovoltaic pumping system. Maximum power point tracking is achieved via an algorithm using Perturb and Observe method, with array voltage and current being used to generate the reference voltage which should be the PV panel’s operating voltage to get maximum available power. A Takagi-Sugeno (T-S) observer has been proposed and designed with non-measurable premise variables and the conditions of stability are given in terms of Linear Matrix Inequality (LMI). The simulation results show the effectiveness and robustness of the proposed method.展开更多
文摘Luminal acidification in the epididymis is an important process for the regulation of male fertility. Low pH and low bicarbonate concentration are among key factors that keep spermatozoa in a dormant state while they mature and are stored in this organ. Although significant bicarbonate reabsorption is achieved by principal cells in the proximal regions of the epididymis, clear and narrow cells are specialized for net proton secretion. Clear cells express very high levels of the vacuolar proton pumping ATPase (V-ATPase) in their apical membrane and are responsible for the bulk of proton secretion. In the present paper, selected aspects of V-ATPase regulation in clear cells are described and potential pathologies associated with mutations of some of the V-ATPase subunits are discussed. (Asian J Androl 2007 July; 9: 476-482)
文摘AIM To compare the outcomes between laparoscopic Nissen fundoplication(LNF)and proton pump inhibitors(PPIs)therapy in patients with laryngopharyngeal reflux(LPR)and typeⅠhiatal hernia diagnosed by oropharyngeal p H-monitoring and symptom-scale assessment.METHODS From February 2014 to January 2015,70 patients who were diagnosed with LPR and type I hiatal hernia and referred for symptomatic assessment,oropharyngeal p H-monitoring,manometry,and gastrointestinal endoscopy were enrolled in this study.All of the patients met the inclusion criteria.All of the patients underwent LNF or PPIs administration,and completed a2-year follow-up.Patients’baseline characteristics and primary outcome measures,including comprehensive and single symptoms of LPR,PPIs independence,and satisfaction,and postoperative complications were assessed.The outcomes of LNF and PPIs therapy were analyzed and compared. RESULTS There were 31 patients in the LNF group and 39patients in the PPI group.Fifty-three patients(25 in the LNF group and 28 in the PPI group)completed reviews and follow-up.Oropharyngeal p H-monitoring parameters were all abnormal with high acid exposure,a large amount of reflux,and a high Ryan score,associated reflux symptom index(RSI)score.There was a significant improvement in the RSI and LPR symptom scores after the 2-year follow-up in both groups(P<0.05),as well as typical symptoms of gastroesophageal reflux disease.Improvement in the RSI(P<0.005)and symptom scores of cough(P=0.032),mucus(P=0.011),and throat clearing(P=0.022)was significantly superior in the LNF group to that in the PPI group.After LNF and PPIs therapy,13 and 53 patients achieved independence from PPIs therapy(LNF:44.0%vs PPI:7.14%,P<0.001)during follow-up,respectively.Patients in the LNF group were more satisfied with their quality of life than those in the PPI group(LNF:62.49±28.68 vs PPI:44.36±32.77,P=0.004).Body mass index was significantly lower in the LNF group than in the PPI group(LNF:22.2±3.1kg/m^2 vs PPI:25.1±2.9 kg/m^2,P=0.001).CONCLUSION Diagnosis of LPR should be assessed with oropharyngeal p H-monitoring,manometry,and the symptom-scale.LNF achieves better improvement than PPIs for LPR with type I hiatal hernia.
文摘Recovering waste heat from industrial processes is bene ficial in order to reduce the primary energy demands and heat pumps can be used to this purpose.Absorption heat pumps are energy-saving and environment-friendly because use working fluids that do not cause ozone depletion and can reduce the global warming emissions.The hybrid heat pump processes combine the conventional vapor-compression and the absorption heat pump cycles.Studies about the simulations and modeling of hybrid heat pumps are few in literature.In this research a mathematical model for single effect absorption and hybrid heat pump is carried out with Chem Cad? 6.0.1.LiBr–H_2O is used as working fluid while electrolytic NRTL and electrolytes latent heat are used as thermodynamic model due to the better results.Binary parameters of activity coef ficients are regressed from experimental vapor pressure data while default constants are used for the solubility expressions.A design of heat pumps is developed and a new modeling of generator is analyzed.The coef ficient of performance of absorption heat pump and hybrid heat pump is equal to 0.7 and 0.83 respectively.For absorption heat pump a sensitivity analysis is carried out to evaluate the effect of temperature and pressure generator,the concentration of Li–Br solution on coef ficient of performance,cooling capacity and working fluid temperature.For hybrid heat pump,the different coef ficients of performance,the primary energy ratio,the generator heat,and the compressor power are analyzed for different values of compressor proportion.Results show that comparing the two systems the hybrid pump allows to save more primary energy,costs and carbon dioxide emissions with respect to absorption heat pump with the increasing of compressor proportion parameter.Future researches should focus on the construction of this heat pumps integrated in chemical processes as a biogas plant or trigeneration systems.
文摘The time domain guideposts requirements of a pump-motor system is transfered into a series of constraints which express the robust performance upper bound and regional poles limits of the closed loop system. Then the servo system control problem is transferred into the problem of robust performance optimizing under regional poles constrains described by linear matrix inequality (LMI). These LMIs are easy to solve through the Matlab LMI-toolbox. Simulations indicate that the controller has excellent dynamic, static and disturbance rejection performance, and the control system is robust and has perfect H2 performance to the bounded external torque disturbance.
文摘We herein evaluate the use of a chemical heat pump (CHP) for upgrading waste heat. CaCl<sub>2</sub> was used in the system of CHP. We evaluated the heat storage and heat releasing of CHP, and confirmed the practicality from the experimental results. The reactor module employed was an aluminum plate-tube heat exchanger with corrugated fins, and the CaCl<sub>2</sub> powder was in the form of a packed bed. Heat storage operation and heat dissipation operation are performed at the same time and supplied to the heat demand destination. At this time, an environmental heat source can be used during the heat radiation operation, and the heat output can release more heat than the heat input during heat storage. The heat discharging and charging characteristics of the reactor module were evaluated experimentally. The coefficient of performance (COP) was calculated for the heat upgrading cycle, and the heat output in the system was determined. A COP of 1.42 and output of 650 W/L, based on the heat exchanger volume, were obtained using a 600 s change time for the heat pump.
文摘In this paper, we propose a H∞ robust observer-based control DC motor based on a photovoltaic pumping system. Maximum power point tracking is achieved via an algorithm using Perturb and Observe method, with array voltage and current being used to generate the reference voltage which should be the PV panel’s operating voltage to get maximum available power. A Takagi-Sugeno (T-S) observer has been proposed and designed with non-measurable premise variables and the conditions of stability are given in terms of Linear Matrix Inequality (LMI). The simulation results show the effectiveness and robustness of the proposed method.