In this paper, geoelectrical field anomalies at Changli and Xingji station in Hebei Province were analyzed before five remote earthquakes. It was found that the anomalies mainly occurred two or three months before ear...In this paper, geoelectrical field anomalies at Changli and Xingji station in Hebei Province were analyzed before five remote earthquakes. It was found that the anomalies mainly occurred two or three months before earthquakes, which is of importance to short-term and impendent earthquake prediction. There exhibited different characteristics in geoelectrical field anomalies, but they were closely related to tidal waves, for example, the increasing in ampli- tude at semidiurnal and semimonthly periods of tidal waves; the decreasing or disappearing in amplitude of tidal waves that should have been recorded normally at that time; while there accompanied incremental signals with high frequency, such as jump variations. It was thought that the formation mechanism of the geoelectrical anoma- lies before strong earthquakes resulted from stress-strain resonance effects when rock was weakened during the preparation process in seismic area, and then signals of electric field propagated to remote stations in free space or crust, and superposed on the geoelectric field tidal waves recorded at the stations, leading to increasing or decreasing in amplitude of geoelectrical tidal waves. The high frequency signals may be related to the variation of rock porosity, permeability and so on beneath the stations, as a result of the dynamic effects of remote earthquakes.展开更多
A precise map of the dispersion of the groundwater potential across each watershed can help decision-makers to exert optimal water management in each region.In this research,the potential of groundwater resources in b...A precise map of the dispersion of the groundwater potential across each watershed can help decision-makers to exert optimal water management in each region.In this research,the potential of groundwater resources in both the Zanjanrood Catchment and the Tarom Region,located in the northwest of Iran,has been studied.Seven effective criteria including slope,land-use,drainage density,spring density,lithology,lineament density,and rainfall are considered.Criteria were first weighted using the Analytical Hierarchical Process(AHP)method and then overlaid by the Technique for Order Preferences by Similarity to Ideal(TOPSIS)model.Finally,the spatial zoning map of groundwater potential was obtained in four categories.A sensitivity analysis was performed to determine the influence of each criterion on the obtained map.The model was verified using both the spatial distribution of the high-discharged production wells and the geophysical-based geoelectric field surveys.The results indicate that the high-discharged wells(>40 l/s)in both regions are dispersed predominantly in the very good zone and,in several cases,in the good zone.Besides,the results from the two-dimensional models of resistivity and induced polarization of geoelectrical field survey are inappropriate agreement with those from the TOPSIS method.Notably,there is no suitable potential zone of groundwater in the surrounding highlands to be used in the future for drinking purposes since the highlands water supply is a strategic supply for drinking.The strategies employed in this study,the results of GIS modeling,and the geoelectrical analysis can be considered for sustainable development of similar arid and semi-arid areas since groundwater is considered as the main supplier of water in such regions.展开更多
A geophysical survey was conducted in the Kelle-Bidjocka village, Messondo subdivision, in the Centre Region, Cameroon. The data acquisition was made by combining Schlumberger profiling and electrical soundings along ...A geophysical survey was conducted in the Kelle-Bidjocka village, Messondo subdivision, in the Centre Region, Cameroon. The data acquisition was made by combining Schlumberger profiling and electrical soundings along six (06) profiles of 1500 m in length for a total of 64 geoelectrical stations’ survey conducted through a variable mesh 100 m × 200 m, or 100 m × 300 m. The equipment used is the DC resistivimeter Syscal Junior 48 (Iris Instrument). Processing and modelling of field data are made by using the Res2Dinv, Qwseln and Surfer software. The investigation methods used are electrical resistivity (DC) and induced polarization (IP) methods. The analyses and interpretations have helped to highlight areas of weakness or conductive discontinuities (fractures, faults, shear zones, etc.) in Precambrian gneiss formations, sometimes undergoing weathering processes. They identify the weathering or mineralogical accumulation horizons, the most promising is a mineralization channel identified in the NE-SW direction. The highlighted mineralization is characterized by strong gradients of chargeability or polarization. Samples and other geological evidences observed in the area are used to associate the most polarizable structures with ferriferous formations. Weakly polarizable and particularly conductive backgrounds identified by the inverse pseudo-sections are thought to be sulphate minerals or groundwater targets for future hydrogeological studies.展开更多
The corrosivity of the top three metres of the soil along a pipeline route was determined using soil electrical resistivity for the emplacement of a conduit intended to serve as a gas pipeline. Fifty-six Schlumberger ...The corrosivity of the top three metres of the soil along a pipeline route was determined using soil electrical resistivity for the emplacement of a conduit intended to serve as a gas pipeline. Fifty-six Schlumberger vertical electrical soundings (VES) were carried using a maximum current electrode separation ranging between 24 - 100 m at 2.0 km interval. The data was interpreted using a 1D inversion technique software (1X1D, Interpex, USA). Model resistivity values were classified in terms of the degree of corrosivity. Generally, the sub-soil condition along the pipeline route is non-aggressive but being slightly or moderately aggressive in certain areas due to local conditions prevailing at the measuring stations. Based on the corrosivity along the pipeline route, appropriate cathodic protection methods are prescribed.展开更多
The Turonian aquifer of the Tadla’s basin shows at present a pronounced reduction of its hydraulic potential linked to overexploitation and deficiency of effective rains.In order to make an evaluation of the resource...The Turonian aquifer of the Tadla’s basin shows at present a pronounced reduction of its hydraulic potential linked to overexploitation and deficiency of effective rains.In order to make an evaluation of the resources of water and implant the exploitation’s drillings of groundwater,a geophysical study by展开更多
To achieve the current study, geoelectrical surveys along six (06) profiles of 4 km long in a 100 m × 200 m grid defined according to the triangulation principle in the Ngoura area (Tindikala-Boutou villages) hav...To achieve the current study, geoelectrical surveys along six (06) profiles of 4 km long in a 100 m × 200 m grid defined according to the triangulation principle in the Ngoura area (Tindikala-Boutou villages) have been made through electrical sounding and profiling following Schlumberger array. The instrument is the resistivimeter Syscal Junior 48 (IRIS Instrument) which uses the electrical current. The data have been processed and modelled with Res2Dinv and Winsev softwares then interpolated with Surfer software. Electrical methods used are the Direct current (DC) and the Induced Polarization (IP). Interpretation and analyses of results from each investigation method highlight weak zones or conductive discontinuities and mineralized zones. Conductive zones have been identified as shear zones within granitic structures of the Precambrian basement, according to the geologic and tectonic background of the area. The structural trend of these shear zones is E-W. The mineralization within it is N-S and characterized by high values of chargeability, essentially in the eastern part of the area under study. This mineralization proves the presence of metalliferous or sulphide heaps disseminated in weathered quartz veins which cross shear zones. Also, the poor mineralization and conductive structures in shear zones characterize the groundwater zones. The intense activities of gold washers encountered in the area enable to link that mineralization to gold within quartz veins. The near surface gold mineralization is eluvial or alluvial, and in depth this mineralization is primary.展开更多
The vertical electrical soundings on the Matam region phosphates deposits are interpreted by inversion. To retrieve lithology from the obtained resistivities, mechanical drilling was performed to compare directly the ...The vertical electrical soundings on the Matam region phosphates deposits are interpreted by inversion. To retrieve lithology from the obtained resistivities, mechanical drilling was performed to compare directly the lithologies and the geoelectrical resistivities. The obtained relation is not simple and is not sufficient to interpret all the VES. This situation motivated the collection of supplementary information from cyclostratigraphy. Geoelectrical and cyclostratigraphic?information is combined using fuzzy logic techniques to build a fuzzy inference system. The obtained results seem to be consistent with the stratigraphy of the investigated region and allow retrieving lithological succession. Further investigations are necessary for more accurate thickness determination.展开更多
A geoelectrical survey using the electrical resistivity method was carried out in the Mayo Boki (Northern Cameroon), to investigate the subsurface layering and evaluation of the limestone characteristics. In addition ...A geoelectrical survey using the electrical resistivity method was carried out in the Mayo Boki (Northern Cameroon), to investigate the subsurface layering and evaluation of the limestone characteristics. In addition to geological data collection, three vertical electrical soundings and one electrical resistivity profile were measured. Joint interpretation of the DC data allows us to obtain reliable 1D models of the resistivity distribution. The interpretation of the field data was carried out using the RES2DINV software, which converts the apparent resistivity as a function of electrode spacing to the true resistivity as a function of depth in two dimensions. The results obtained from the electrical resistivity survey showed that: 1) A limestone layer was put in evidence at a depth of 4 m and the thickness varies from 13 m to 44 m;2) The limestone layer resistivity is ranged from 125 to 2410 ohm.m;3) An area of probable limestone deposit with interesting thicknesses have been identified. These facts are useful for future mining exploration as drilling map definition and operations. The geologic section of a nearby location termed resistivity profile was delineated and its total depth was found to be 57 m, which corroborates the lithologs of the boreholes from the area. The correlation of geological data and the geoelectric section has led to envisage pursuing exploration activities. Based on the limestone layer characteristics extracted from this DC investigation, the exploration drilling operations have to be initiated in order to define the limestone resource over the area of study, which will certainly enables to built the exploitation project prefeasibility document.展开更多
Water seepage erosion has been and remains one of the major engineering problems. However, most engineers will much depend on borehole data and soil test for designing and problem detection. By considering of the cost...Water seepage erosion has been and remains one of the major engineering problems. However, most engineers will much depend on borehole data and soil test for designing and problem detection. By considering of the cost and destructive method, selection of geoelectrical prospecting would be appropriate. Therefore, two electrical geophysical surveys were carried out in Sekolah Menengah Kebangsaan Dato’ Haji Mohd Nor, Gelugor, Pulau Pinang to map the presence of the unknown underground water sources (saturated zones) and its movement. With the total of seven resistivity lines parallel to each other and self potential (SP) with 5 m × 5 m gridding survey were successfully done. The resistivity result from line 1 (R1) to line 6 (R6) shows the subsurface consist of saturated zones with range between 3 m up to 10 m depth, before it reaches the R7 which is believed as the accumulation zone. Meanwhile, as for SP result it shows the water flow from higher value (north-east) towards the lower value which is mostly at the south area. In conclusion, geoelectrical survey could assist in detecting and solving engineering problems as it proven by the result from each method.展开更多
The temporal evolution of shear-wave splitting and geoelectrical anisotropy of earth media during the preparation and occurrence of the Yongdeng MS5.8 earthquake is studied based on the digital seismic data and contin...The temporal evolution of shear-wave splitting and geoelectrical anisotropy of earth media during the preparation and occurrence of the Yongdeng MS5.8 earthquake is studied based on the digital seismic data and continuous magnetotelluric (MT) records. The results show that the direction of polarization of the fast S-wave gradually rotated from north by east to north by west before the Yongdeng earthquake and returned to north by east after the earthquake. Moreover, the time delay between the fast S wave and slow S wave increased to the largest until the earthquake occurred. On the other hand, the directions of geoelectrical principal axes also changed before earthquake, and exhibited identical characteristics in the frequency domain. The direction of the axis (pxy), which was originally perpendicular to the fault near station, varied from N17°to N15°before earthquake, and returned to north by east after the earthquake. Correspondingly, the change of pxy was most obvious in the period range of 160 s to 226 s, but the variation of pyx was less obvious. The focal mechanism solution of the earthquake showed that the direction of P-axis was N15°. Conclusions are: (1) The fast S-wave polarization, one of the geoelectrical principal axes and the P-axis were in agreement in orientation during earthquake preparation, which is the result of the alignment of EDA cracks; (2) The fact that the geoelectrical axes identically varied with frequency demonstrated that EDA is really widespread in the crust; (3) The variation of MT apparent resistivity also showed the existence of anisotropy and has its own features: The static anisotropy of resistivity is controlled by the tectonic conditions of the station, while the dynamic anisotropy is caused and affected by the seismic stress field; The resistivity along the axis parallel to the P-axis showed the most obvious variation, while the difference in variation with frequency shows that the variation of resistivity depends not only on direction but also on buried depth.展开更多
A geophysical investigation of subsurface structures using the Syscal Junior 48 resistivity-meter was conducted in Ngoura subdivision (East Cameroon) following a combined geoelectrical direct current (DC) approach inv...A geophysical investigation of subsurface structures using the Syscal Junior 48 resistivity-meter was conducted in Ngoura subdivision (East Cameroon) following a combined geoelectrical direct current (DC) approach involving Resistivity and IP methods. This investigation was allowed to collect data on forty-five (45) profiling lines at three acquisition levels (AB = 100 m, MN = 10 m;AB = 200 m, MN = 20 m and AB = 500 m, MN = 50 m) and two electric panels L1 and L4, using the Schlumberger array. Processing, modeling and interpretation of data collected using the Winsev, Res2Dinv and Surfer software helped in highlighting a conductive and strongly mineralized discontinuity in granite formations, which lined up with the NE-SW Kadei tectonic line. It extends beyond 100 m depth over an average width of 600 m. The mineralization associated with this discontinuity is identified by a high concentration of disseminated metalliferous minerals in quartz or pegmatite veins. The mining reconnaissance works in the study area and those of several authors have characterized this anomaly to a lode gold quartz or large pegmatite. The results of this study correlate with geological and tectonic data for the region marked by NE-SW Kadei tectonic line. Therefore, they confirm the reliability of a geoelectrical DC investigation method combining Resistivity and IP to the identification of ore bodies.展开更多
A geoelectrical survey using the electrical resistivity method was carried out in some villages in the western region of Cameroon to investigate the sub-surface layers and evaluate the characteristics of aquifers. The...A geoelectrical survey using the electrical resistivity method was carried out in some villages in the western region of Cameroon to investigate the sub-surface layers and evaluate the characteristics of aquifers. The direct current electrical resistivity method was utilized for the present study. Applying the Schlumberger array, a total of twenty four (24) Vertical Electrical Soundings (VES) were conducted. Quantitative and qualitative interpretations of data were carried out to determine the nature and thickness of the aquifer zone combined with existing litho-logs aided correlation of geoelectric sections to litho-logs. Four to five geoelectric layers were delineated from the survey area. The first layer which is the topsoil has resistivity values ranging from 6 - 949 Ωm and the thickness is between 0.2 - 4.2 m. The second layer which is made up of clay and laterite has resistivity values ranging between 9 - 1862 Ωm and thickness range from 1.0 - 16.4 m. The third and fourth geoelectric layers are made up of clay and granite/basalts with thickness varying from 2.2 - 39.5 m which corresponds to an aquifer horizon. Resistivity values of the aquifer ranges from 10 to 70,506 Ωm. The resistivity map drawn from these measurements shows the presence of a low resistivity zone which indicates the reflection in the direction of ground water from northeast to southwest with the recharge concentrated to the south of the study area. This study has revealed for this area, an average depth of the aquifer of 32 m with the average thickness of the aquifer being 22 m. The geoelectric sections of some VES stations demarcated corroborate very well with the geological description of the area.展开更多
Vertical electrical sounding(VES) was carried out in northern part of Paiko, North Central Nigeria, using Abem terrameter model SAS 4000 to determine the subsurface layer parameters(resistivities, depths and thickn...Vertical electrical sounding(VES) was carried out in northern part of Paiko, North Central Nigeria, using Abem terrameter model SAS 4000 to determine the subsurface layer parameters(resistivities, depths and thickness) employed in delineating the groundwater potential of the area. A total of six transverses with ten VES stations along each traverse, at intervals of 50 m were investigated. It has a maximum current electrode separation(AB/2) of 100 m. Three to four distinct geoelectric layers were observed, namely, the top layer, the weathered layer, the fractured/fresh layer, and the fresh basement layer. The observed frequencies in curve types include 21% of H, 4.2% of HA, 2.4% of K, 4.2% of A, 1.67% of KH and 3% of HK. Eight VES stations were delineated as ground water potentials of the area, with third and fourth layer resistivities ranging from 191 to 398 ?·m. Depths range from 13.60 to 36.60 m and thickness varies from 9.23 to 30.51 m. A correlation of the borehole log with the VES lithology is in agreement. Viable boreholes for good portable water should be sited at VES stations J8 and J10 having a fine aquifer at a depth of 36.60 and 17.80 m respectively with thickness of 30.51 and 15.07 m, respectively.展开更多
The presence of groundwater is strongly related to its geological and geohydrological conditions.It is,however,important to study the groundwater potential in an area before it is utilized to provide clean water.Werne...The presence of groundwater is strongly related to its geological and geohydrological conditions.It is,however,important to study the groundwater potential in an area before it is utilized to provide clean water.Werner-Schlumberger’s method was used to analyze the groundwater potential while hydraulic properties such as soil porosity and hydraulic conductivity were used to determine the quality and ability of the soil to allow water’s movement in the aquifer.The results show that the aquifer in the Sekara and Kemuning Muda is at a depth of more than 6 meters below the ground level with moderate groundwater potential.It is also found that the aquifer at depths of over 60 m have high groundwater potential.Moreover,soil porosity in Kemuning is found to be average while the ability to conduct water was moderate.This makes it possible for some surface water to seep into the soil while the remaining flows to the rivers and ditches.展开更多
The geoelectrical investigation of the proposed Aba River dam at Amapu-Ideobia, Akanu Ngwa Southeastern Nigeria has been carried out. The objective of this study is to determine the downward and lateral trends of the ...The geoelectrical investigation of the proposed Aba River dam at Amapu-Ideobia, Akanu Ngwa Southeastern Nigeria has been carried out. The objective of this study is to determine the downward and lateral trends of the rock layers or units along and near the proposed dam axis and deduce the possible structures that may enhance workable design of the dam. ABEM Terrameter SAS 4000 model was used and the symmetrical Schlumberger configuration was adopted. Twelve (12) Vertical Electrical Sounding stations were located and fully occupied along the dam axis. Preliminary input data from the field were fed into Zohdy software to generate real resistivities and depths to geoelectric layers. Five geoelectric layers were interpreted as Loamy Top soil, Alluvial matter, Pebble bed, Sandy lateritic and Gravely sand. Layer 1 (the top loamy soil) was encountered in VES 1, 2, 3, 4, 5, 9, 10, 11 and 12 locations with maximum thickness of 1.5 m in VES 3 and 4. Resistivity values ranged from 216 to 519 Ohm-m. The second layer (lateritic matter) had a maximum lower depth of 5 m in VES 3 and 4 points. This was not encountered in VES 6 point being replaced by alluvium. Resistivity values ranged from 101 to 6190 Ohm-m. Layer 3 was interpreted as a restricted pebble bed which occurred only at VES 6, 7 and 8 locations flanking the river course with thickness of about 3.5 m and resistivity values range of 182 415 Ohm-m. The fourth layer was modeled as the alluvial matter and restricted to the river course (VES 6, 7, 8) locations with base at between 12.5 m in VES 8 and 8 m in VES 6. The last modeled layer (Layer 5) was composed of gravely sandstone that underlined the whole study area apart from the restricted pebble bed at the NE crestal portion (VES 12). No structures like fractures, lineaments and faults that would be of deleterious effect were observed in all the VES points down to about 40 m. However, it was observed that the axial length had overriding sandy matter with high porosity and potentially rife for great infiltration;a condition that could facilitate seepage around the reservoir portion of the dam.展开更多
An assessment of the protective capacity of the vadose zone overlyingthe aquifer systems in the Kaltungo area was carried out to determine itsinfluence on groundwater quality. Applying the schlumberger array with amax...An assessment of the protective capacity of the vadose zone overlyingthe aquifer systems in the Kaltungo area was carried out to determine itsinfluence on groundwater quality. Applying the schlumberger array with amaximum electrode spread AB/2 = 100m through VES, thirty water wellpoints were surveyed using Omega terrameter (PIOSO1) resistivity meter.The field data was first subjected to manual interpretation through curvemarching and then digitized modeled curves using computer software. Theinterpreted data revealed that the area is characterized by eleven differentcurve types representing three to five geo electrical layers. In order toassess the protective capacity of the vadoze zone over the aquifer systems,the longitudinal conductance (S) and transverse resistance (T) (secondarygeoelectric parameters) were computed from the primary data using theDar Zarouk formula. The values of S obtained range from 0.0018 to 0.4056ohms with a mean value of 0.0135 ohms while the values of T range from0.55 ohms to 1195.68 ohms with a mean value of 39.84 ohms. The valuesof S and T obtained reveal that 90% of probed points has poor protectivecapacity, 10 % has moderate protective capacity and 83 % has hightransmissivity, 17 % has intermediate transmissivity. The T and S values areskewed towards poorly protective capacity thus making groundwater in thearea highly vulnerable to contamination from the surface. To achieve goodgroundwater quality in the area, proper completion of newly constructedwells should install protective casing through the entire vadose zone.展开更多
In China, efforts are being made to monitor geoelectric fields through a large network of stations deployed and managed by the China Earthquake Administration. The diurnal variations in the geoelectric field waveforms...In China, efforts are being made to monitor geoelectric fields through a large network of stations deployed and managed by the China Earthquake Administration. The diurnal variations in the geoelectric field waveforms were similar in the quiet magnetic periods when K〈5 (generally, K〈3 indicates a quiet time). The arrival time points of the maxima in the geoelectric field waveforms exhibited differences in local time related to geographic longitude. The amplitude of diurnal variation was several to 16.6 mV/km and decreased with increasing latitude. Further, the amplitude of diurnal variation, which was related to seasonal changes, was larger in summer and autumn than in spring and winter. The periods of diurnal changes during quiet days were 24, 12, 8, 6, 4 hours and several minutes over large areas. Finally, the observed diurnal variations in geoelectric field prior to the Alxa Zuoqi Ms5.8 earthquake on 15 April 2015 were studied, and pronounced changes in the spectral values of the geoelectric fields were found to be associated with the Alxa Zuoqi earthquake in Inner Mongolia.展开更多
Geoelectrical soundings using the Schlumberger array were carried out in the vicinity of 23 pumping test sites to determine aquifer parameters, central Jordan. On the basis of aquifer geometry, the area has been di-vi...Geoelectrical soundings using the Schlumberger array were carried out in the vicinity of 23 pumping test sites to determine aquifer parameters, central Jordan. On the basis of aquifer geometry, the area has been di-vided into two hydraulic units: the northern flood plain and the flood plain to its south. Field resistivity data are interpreted in terms of the true resistivity and thickness of subsurface layers. These parameters are then correlated with the available pumping test data. Significant correlations between the transmissivity and modified transverse resistance as well as between the hydraulic conductivity and formation factor were ob-tained for the two hydraulic units, in central Jordan are presented here.展开更多
基金National Key Project of Science and Technology (2004BA601B010503)
文摘In this paper, geoelectrical field anomalies at Changli and Xingji station in Hebei Province were analyzed before five remote earthquakes. It was found that the anomalies mainly occurred two or three months before earthquakes, which is of importance to short-term and impendent earthquake prediction. There exhibited different characteristics in geoelectrical field anomalies, but they were closely related to tidal waves, for example, the increasing in ampli- tude at semidiurnal and semimonthly periods of tidal waves; the decreasing or disappearing in amplitude of tidal waves that should have been recorded normally at that time; while there accompanied incremental signals with high frequency, such as jump variations. It was thought that the formation mechanism of the geoelectrical anoma- lies before strong earthquakes resulted from stress-strain resonance effects when rock was weakened during the preparation process in seismic area, and then signals of electric field propagated to remote stations in free space or crust, and superposed on the geoelectric field tidal waves recorded at the stations, leading to increasing or decreasing in amplitude of geoelectrical tidal waves. The high frequency signals may be related to the variation of rock porosity, permeability and so on beneath the stations, as a result of the dynamic effects of remote earthquakes.
文摘A precise map of the dispersion of the groundwater potential across each watershed can help decision-makers to exert optimal water management in each region.In this research,the potential of groundwater resources in both the Zanjanrood Catchment and the Tarom Region,located in the northwest of Iran,has been studied.Seven effective criteria including slope,land-use,drainage density,spring density,lithology,lineament density,and rainfall are considered.Criteria were first weighted using the Analytical Hierarchical Process(AHP)method and then overlaid by the Technique for Order Preferences by Similarity to Ideal(TOPSIS)model.Finally,the spatial zoning map of groundwater potential was obtained in four categories.A sensitivity analysis was performed to determine the influence of each criterion on the obtained map.The model was verified using both the spatial distribution of the high-discharged production wells and the geophysical-based geoelectric field surveys.The results indicate that the high-discharged wells(>40 l/s)in both regions are dispersed predominantly in the very good zone and,in several cases,in the good zone.Besides,the results from the two-dimensional models of resistivity and induced polarization of geoelectrical field survey are inappropriate agreement with those from the TOPSIS method.Notably,there is no suitable potential zone of groundwater in the surrounding highlands to be used in the future for drinking purposes since the highlands water supply is a strategic supply for drinking.The strategies employed in this study,the results of GIS modeling,and the geoelectrical analysis can be considered for sustainable development of similar arid and semi-arid areas since groundwater is considered as the main supplier of water in such regions.
文摘A geophysical survey was conducted in the Kelle-Bidjocka village, Messondo subdivision, in the Centre Region, Cameroon. The data acquisition was made by combining Schlumberger profiling and electrical soundings along six (06) profiles of 1500 m in length for a total of 64 geoelectrical stations’ survey conducted through a variable mesh 100 m × 200 m, or 100 m × 300 m. The equipment used is the DC resistivimeter Syscal Junior 48 (Iris Instrument). Processing and modelling of field data are made by using the Res2Dinv, Qwseln and Surfer software. The investigation methods used are electrical resistivity (DC) and induced polarization (IP) methods. The analyses and interpretations have helped to highlight areas of weakness or conductive discontinuities (fractures, faults, shear zones, etc.) in Precambrian gneiss formations, sometimes undergoing weathering processes. They identify the weathering or mineralogical accumulation horizons, the most promising is a mineralization channel identified in the NE-SW direction. The highlighted mineralization is characterized by strong gradients of chargeability or polarization. Samples and other geological evidences observed in the area are used to associate the most polarizable structures with ferriferous formations. Weakly polarizable and particularly conductive backgrounds identified by the inverse pseudo-sections are thought to be sulphate minerals or groundwater targets for future hydrogeological studies.
文摘The corrosivity of the top three metres of the soil along a pipeline route was determined using soil electrical resistivity for the emplacement of a conduit intended to serve as a gas pipeline. Fifty-six Schlumberger vertical electrical soundings (VES) were carried using a maximum current electrode separation ranging between 24 - 100 m at 2.0 km interval. The data was interpreted using a 1D inversion technique software (1X1D, Interpex, USA). Model resistivity values were classified in terms of the degree of corrosivity. Generally, the sub-soil condition along the pipeline route is non-aggressive but being slightly or moderately aggressive in certain areas due to local conditions prevailing at the measuring stations. Based on the corrosivity along the pipeline route, appropriate cathodic protection methods are prescribed.
文摘The Turonian aquifer of the Tadla’s basin shows at present a pronounced reduction of its hydraulic potential linked to overexploitation and deficiency of effective rains.In order to make an evaluation of the resources of water and implant the exploitation’s drillings of groundwater,a geophysical study by
文摘To achieve the current study, geoelectrical surveys along six (06) profiles of 4 km long in a 100 m × 200 m grid defined according to the triangulation principle in the Ngoura area (Tindikala-Boutou villages) have been made through electrical sounding and profiling following Schlumberger array. The instrument is the resistivimeter Syscal Junior 48 (IRIS Instrument) which uses the electrical current. The data have been processed and modelled with Res2Dinv and Winsev softwares then interpolated with Surfer software. Electrical methods used are the Direct current (DC) and the Induced Polarization (IP). Interpretation and analyses of results from each investigation method highlight weak zones or conductive discontinuities and mineralized zones. Conductive zones have been identified as shear zones within granitic structures of the Precambrian basement, according to the geologic and tectonic background of the area. The structural trend of these shear zones is E-W. The mineralization within it is N-S and characterized by high values of chargeability, essentially in the eastern part of the area under study. This mineralization proves the presence of metalliferous or sulphide heaps disseminated in weathered quartz veins which cross shear zones. Also, the poor mineralization and conductive structures in shear zones characterize the groundwater zones. The intense activities of gold washers encountered in the area enable to link that mineralization to gold within quartz veins. The near surface gold mineralization is eluvial or alluvial, and in depth this mineralization is primary.
文摘The vertical electrical soundings on the Matam region phosphates deposits are interpreted by inversion. To retrieve lithology from the obtained resistivities, mechanical drilling was performed to compare directly the lithologies and the geoelectrical resistivities. The obtained relation is not simple and is not sufficient to interpret all the VES. This situation motivated the collection of supplementary information from cyclostratigraphy. Geoelectrical and cyclostratigraphic?information is combined using fuzzy logic techniques to build a fuzzy inference system. The obtained results seem to be consistent with the stratigraphy of the investigated region and allow retrieving lithological succession. Further investigations are necessary for more accurate thickness determination.
文摘A geoelectrical survey using the electrical resistivity method was carried out in the Mayo Boki (Northern Cameroon), to investigate the subsurface layering and evaluation of the limestone characteristics. In addition to geological data collection, three vertical electrical soundings and one electrical resistivity profile were measured. Joint interpretation of the DC data allows us to obtain reliable 1D models of the resistivity distribution. The interpretation of the field data was carried out using the RES2DINV software, which converts the apparent resistivity as a function of electrode spacing to the true resistivity as a function of depth in two dimensions. The results obtained from the electrical resistivity survey showed that: 1) A limestone layer was put in evidence at a depth of 4 m and the thickness varies from 13 m to 44 m;2) The limestone layer resistivity is ranged from 125 to 2410 ohm.m;3) An area of probable limestone deposit with interesting thicknesses have been identified. These facts are useful for future mining exploration as drilling map definition and operations. The geologic section of a nearby location termed resistivity profile was delineated and its total depth was found to be 57 m, which corroborates the lithologs of the boreholes from the area. The correlation of geological data and the geoelectric section has led to envisage pursuing exploration activities. Based on the limestone layer characteristics extracted from this DC investigation, the exploration drilling operations have to be initiated in order to define the limestone resource over the area of study, which will certainly enables to built the exploitation project prefeasibility document.
文摘Water seepage erosion has been and remains one of the major engineering problems. However, most engineers will much depend on borehole data and soil test for designing and problem detection. By considering of the cost and destructive method, selection of geoelectrical prospecting would be appropriate. Therefore, two electrical geophysical surveys were carried out in Sekolah Menengah Kebangsaan Dato’ Haji Mohd Nor, Gelugor, Pulau Pinang to map the presence of the unknown underground water sources (saturated zones) and its movement. With the total of seven resistivity lines parallel to each other and self potential (SP) with 5 m × 5 m gridding survey were successfully done. The resistivity result from line 1 (R1) to line 6 (R6) shows the subsurface consist of saturated zones with range between 3 m up to 10 m depth, before it reaches the R7 which is believed as the accumulation zone. Meanwhile, as for SP result it shows the water flow from higher value (north-east) towards the lower value which is mostly at the south area. In conclusion, geoelectrical survey could assist in detecting and solving engineering problems as it proven by the result from each method.
基金This study was carried out at the Earthquake Research Institute of Lanzhou of CSB,supported by the Natural Science Foundation of Gansu Province(ZS991-A25-013-Z)the CSB key projecl of“9th Five-year Plan"(95-07-436)the Joint Foundation of Seismological Science(198115)of CSB.
文摘The temporal evolution of shear-wave splitting and geoelectrical anisotropy of earth media during the preparation and occurrence of the Yongdeng MS5.8 earthquake is studied based on the digital seismic data and continuous magnetotelluric (MT) records. The results show that the direction of polarization of the fast S-wave gradually rotated from north by east to north by west before the Yongdeng earthquake and returned to north by east after the earthquake. Moreover, the time delay between the fast S wave and slow S wave increased to the largest until the earthquake occurred. On the other hand, the directions of geoelectrical principal axes also changed before earthquake, and exhibited identical characteristics in the frequency domain. The direction of the axis (pxy), which was originally perpendicular to the fault near station, varied from N17°to N15°before earthquake, and returned to north by east after the earthquake. Correspondingly, the change of pxy was most obvious in the period range of 160 s to 226 s, but the variation of pyx was less obvious. The focal mechanism solution of the earthquake showed that the direction of P-axis was N15°. Conclusions are: (1) The fast S-wave polarization, one of the geoelectrical principal axes and the P-axis were in agreement in orientation during earthquake preparation, which is the result of the alignment of EDA cracks; (2) The fact that the geoelectrical axes identically varied with frequency demonstrated that EDA is really widespread in the crust; (3) The variation of MT apparent resistivity also showed the existence of anisotropy and has its own features: The static anisotropy of resistivity is controlled by the tectonic conditions of the station, while the dynamic anisotropy is caused and affected by the seismic stress field; The resistivity along the axis parallel to the P-axis showed the most obvious variation, while the difference in variation with frequency shows that the variation of resistivity depends not only on direction but also on buried depth.
文摘A geophysical investigation of subsurface structures using the Syscal Junior 48 resistivity-meter was conducted in Ngoura subdivision (East Cameroon) following a combined geoelectrical direct current (DC) approach involving Resistivity and IP methods. This investigation was allowed to collect data on forty-five (45) profiling lines at three acquisition levels (AB = 100 m, MN = 10 m;AB = 200 m, MN = 20 m and AB = 500 m, MN = 50 m) and two electric panels L1 and L4, using the Schlumberger array. Processing, modeling and interpretation of data collected using the Winsev, Res2Dinv and Surfer software helped in highlighting a conductive and strongly mineralized discontinuity in granite formations, which lined up with the NE-SW Kadei tectonic line. It extends beyond 100 m depth over an average width of 600 m. The mineralization associated with this discontinuity is identified by a high concentration of disseminated metalliferous minerals in quartz or pegmatite veins. The mining reconnaissance works in the study area and those of several authors have characterized this anomaly to a lode gold quartz or large pegmatite. The results of this study correlate with geological and tectonic data for the region marked by NE-SW Kadei tectonic line. Therefore, they confirm the reliability of a geoelectrical DC investigation method combining Resistivity and IP to the identification of ore bodies.
文摘A geoelectrical survey using the electrical resistivity method was carried out in some villages in the western region of Cameroon to investigate the sub-surface layers and evaluate the characteristics of aquifers. The direct current electrical resistivity method was utilized for the present study. Applying the Schlumberger array, a total of twenty four (24) Vertical Electrical Soundings (VES) were conducted. Quantitative and qualitative interpretations of data were carried out to determine the nature and thickness of the aquifer zone combined with existing litho-logs aided correlation of geoelectric sections to litho-logs. Four to five geoelectric layers were delineated from the survey area. The first layer which is the topsoil has resistivity values ranging from 6 - 949 Ωm and the thickness is between 0.2 - 4.2 m. The second layer which is made up of clay and laterite has resistivity values ranging between 9 - 1862 Ωm and thickness range from 1.0 - 16.4 m. The third and fourth geoelectric layers are made up of clay and granite/basalts with thickness varying from 2.2 - 39.5 m which corresponds to an aquifer horizon. Resistivity values of the aquifer ranges from 10 to 70,506 Ωm. The resistivity map drawn from these measurements shows the presence of a low resistivity zone which indicates the reflection in the direction of ground water from northeast to southwest with the recharge concentrated to the south of the study area. This study has revealed for this area, an average depth of the aquifer of 32 m with the average thickness of the aquifer being 22 m. The geoelectric sections of some VES stations demarcated corroborate very well with the geological description of the area.
文摘Vertical electrical sounding(VES) was carried out in northern part of Paiko, North Central Nigeria, using Abem terrameter model SAS 4000 to determine the subsurface layer parameters(resistivities, depths and thickness) employed in delineating the groundwater potential of the area. A total of six transverses with ten VES stations along each traverse, at intervals of 50 m were investigated. It has a maximum current electrode separation(AB/2) of 100 m. Three to four distinct geoelectric layers were observed, namely, the top layer, the weathered layer, the fractured/fresh layer, and the fresh basement layer. The observed frequencies in curve types include 21% of H, 4.2% of HA, 2.4% of K, 4.2% of A, 1.67% of KH and 3% of HK. Eight VES stations were delineated as ground water potentials of the area, with third and fourth layer resistivities ranging from 191 to 398 ?·m. Depths range from 13.60 to 36.60 m and thickness varies from 9.23 to 30.51 m. A correlation of the borehole log with the VES lithology is in agreement. Viable boreholes for good portable water should be sited at VES stations J8 and J10 having a fine aquifer at a depth of 36.60 and 17.80 m respectively with thickness of 30.51 and 15.07 m, respectively.
文摘The presence of groundwater is strongly related to its geological and geohydrological conditions.It is,however,important to study the groundwater potential in an area before it is utilized to provide clean water.Werner-Schlumberger’s method was used to analyze the groundwater potential while hydraulic properties such as soil porosity and hydraulic conductivity were used to determine the quality and ability of the soil to allow water’s movement in the aquifer.The results show that the aquifer in the Sekara and Kemuning Muda is at a depth of more than 6 meters below the ground level with moderate groundwater potential.It is also found that the aquifer at depths of over 60 m have high groundwater potential.Moreover,soil porosity in Kemuning is found to be average while the ability to conduct water was moderate.This makes it possible for some surface water to seep into the soil while the remaining flows to the rivers and ditches.
文摘The geoelectrical investigation of the proposed Aba River dam at Amapu-Ideobia, Akanu Ngwa Southeastern Nigeria has been carried out. The objective of this study is to determine the downward and lateral trends of the rock layers or units along and near the proposed dam axis and deduce the possible structures that may enhance workable design of the dam. ABEM Terrameter SAS 4000 model was used and the symmetrical Schlumberger configuration was adopted. Twelve (12) Vertical Electrical Sounding stations were located and fully occupied along the dam axis. Preliminary input data from the field were fed into Zohdy software to generate real resistivities and depths to geoelectric layers. Five geoelectric layers were interpreted as Loamy Top soil, Alluvial matter, Pebble bed, Sandy lateritic and Gravely sand. Layer 1 (the top loamy soil) was encountered in VES 1, 2, 3, 4, 5, 9, 10, 11 and 12 locations with maximum thickness of 1.5 m in VES 3 and 4. Resistivity values ranged from 216 to 519 Ohm-m. The second layer (lateritic matter) had a maximum lower depth of 5 m in VES 3 and 4 points. This was not encountered in VES 6 point being replaced by alluvium. Resistivity values ranged from 101 to 6190 Ohm-m. Layer 3 was interpreted as a restricted pebble bed which occurred only at VES 6, 7 and 8 locations flanking the river course with thickness of about 3.5 m and resistivity values range of 182 415 Ohm-m. The fourth layer was modeled as the alluvial matter and restricted to the river course (VES 6, 7, 8) locations with base at between 12.5 m in VES 8 and 8 m in VES 6. The last modeled layer (Layer 5) was composed of gravely sandstone that underlined the whole study area apart from the restricted pebble bed at the NE crestal portion (VES 12). No structures like fractures, lineaments and faults that would be of deleterious effect were observed in all the VES points down to about 40 m. However, it was observed that the axial length had overriding sandy matter with high porosity and potentially rife for great infiltration;a condition that could facilitate seepage around the reservoir portion of the dam.
文摘An assessment of the protective capacity of the vadose zone overlyingthe aquifer systems in the Kaltungo area was carried out to determine itsinfluence on groundwater quality. Applying the schlumberger array with amaximum electrode spread AB/2 = 100m through VES, thirty water wellpoints were surveyed using Omega terrameter (PIOSO1) resistivity meter.The field data was first subjected to manual interpretation through curvemarching and then digitized modeled curves using computer software. Theinterpreted data revealed that the area is characterized by eleven differentcurve types representing three to five geo electrical layers. In order toassess the protective capacity of the vadoze zone over the aquifer systems,the longitudinal conductance (S) and transverse resistance (T) (secondarygeoelectric parameters) were computed from the primary data using theDar Zarouk formula. The values of S obtained range from 0.0018 to 0.4056ohms with a mean value of 0.0135 ohms while the values of T range from0.55 ohms to 1195.68 ohms with a mean value of 39.84 ohms. The valuesof S and T obtained reveal that 90% of probed points has poor protectivecapacity, 10 % has moderate protective capacity and 83 % has hightransmissivity, 17 % has intermediate transmissivity. The T and S values areskewed towards poorly protective capacity thus making groundwater in thearea highly vulnerable to contamination from the surface. To achieve goodgroundwater quality in the area, proper completion of newly constructedwells should install protective casing through the entire vadose zone.
基金supported by the National Natural Science Foundation of China (No. 41374080)
文摘In China, efforts are being made to monitor geoelectric fields through a large network of stations deployed and managed by the China Earthquake Administration. The diurnal variations in the geoelectric field waveforms were similar in the quiet magnetic periods when K〈5 (generally, K〈3 indicates a quiet time). The arrival time points of the maxima in the geoelectric field waveforms exhibited differences in local time related to geographic longitude. The amplitude of diurnal variation was several to 16.6 mV/km and decreased with increasing latitude. Further, the amplitude of diurnal variation, which was related to seasonal changes, was larger in summer and autumn than in spring and winter. The periods of diurnal changes during quiet days were 24, 12, 8, 6, 4 hours and several minutes over large areas. Finally, the observed diurnal variations in geoelectric field prior to the Alxa Zuoqi Ms5.8 earthquake on 15 April 2015 were studied, and pronounced changes in the spectral values of the geoelectric fields were found to be associated with the Alxa Zuoqi earthquake in Inner Mongolia.
文摘Geoelectrical soundings using the Schlumberger array were carried out in the vicinity of 23 pumping test sites to determine aquifer parameters, central Jordan. On the basis of aquifer geometry, the area has been di-vided into two hydraulic units: the northern flood plain and the flood plain to its south. Field resistivity data are interpreted in terms of the true resistivity and thickness of subsurface layers. These parameters are then correlated with the available pumping test data. Significant correlations between the transmissivity and modified transverse resistance as well as between the hydraulic conductivity and formation factor were ob-tained for the two hydraulic units, in central Jordan are presented here.