Accurately determining when and what to remanufacture is essential for maximizing the lifecycle value of industrial equipment.However,existing approaches face three significant limitations:(1)reliance on predefined ma...Accurately determining when and what to remanufacture is essential for maximizing the lifecycle value of industrial equipment.However,existing approaches face three significant limitations:(1)reliance on predefined mathematical models that often fail to capture equipment-specific degradation,(2)offline optimization methods that assume access to future data,and(3)the absence of component-level guidance.To address these challenges,we propose a data-driven framework for component-level decision-making.The framework leverages streaming sensor data to predict the remaining useful life(RUL)without relying on mathematical models,employs an online optimization algorithm suitable for practical settings,and,through remanufacturing simulations,provides guidance on which components should be replaced.In a case study on gas-insulated switchgear,the proposed framework achieved RUL prediction performance comparable to an oracle model in an online setting without relying on predefined mathematical models.Furthermore,by employing online optimization,it determined a remanufacturing timing close to the global optimum using only past and current data.In addition,unlike previous studies,the framework enables component-level decision-making,allowing for more detailed and actionable remanufacturing guidance in practical applications.展开更多
The development of high-voltage direct current gas-insulated switchgear assemblies(DC GIS)of rated voltages up to±550 kV has been completed.DC GIS provide a compact technical solution with a high functional densi...The development of high-voltage direct current gas-insulated switchgear assemblies(DC GIS)of rated voltages up to±550 kV has been completed.DC GIS provide a compact technical solution with a high functional density,optimized for projects with limited space as in offshore HVDC converter platforms,onshore HVDC converter stations and transition stations between different transmission media.Up to now,no standards for testing of gas-insulated DC systems are available,although pre-standardization work is in progress within CIGRE.Some tests can be performed as required in AC GIS standards.Special aspects of DC voltage stress,like the electric field distribution of insulators influenced by the accumulation of electrical charge carriers and the operation-related inhomogeneous temperature distribution,must be considered by additional electric and thermoelectric tests.For DC GIS,the experience of long-term performance is limited today.Although ageing is expected to be of lower importance,tests are recommended.This contribution summarizes the physical and technical background to design and develop compact DC switchgear assemblies using gas-insulated technology.It explains the developed modules of the substation and gives an overview of the performed tests.Furthermore,it provides an insight in the on-going standardization activities and describes applications in converter and transition stations,showing its space-saving characteristics.展开更多
The construction of the future energy structure of China under the 2050 carbon-neutral vision requires compact direct current(DC)gas-insulation equipment as important nodes and solutions to support electric power tran...The construction of the future energy structure of China under the 2050 carbon-neutral vision requires compact direct current(DC)gas-insulation equipment as important nodes and solutions to support electric power transmission and distribution of long-distance and large-capacity.This paper reviews China's 10-year progress in DC gas-insulated equipment.Important progresses in basic research and industry perspective are presented,with related scientific issues and technical bottlenecks being discussed.The progress in DC gas-insulated equipment worldwide(Europe,Japan,America)is also reported briefly.展开更多
Transient enclosure voltage(TEV),which is a phenomenon induced by the inner dielectric breakdown of SF_6 during disconnector operations in a gas-insulated switchgear(GIS),may cause issues relating to shock hazard ...Transient enclosure voltage(TEV),which is a phenomenon induced by the inner dielectric breakdown of SF_6 during disconnector operations in a gas-insulated switchgear(GIS),may cause issues relating to shock hazard and electromagnetic interference to secondary equipment.This is a critical factor regarding the electromagnetic compatibility of ultra-high-voltage(UHV)substations.In this paper,the statistical characteristics of TEV at UHV level are collected from field experiments,and are analyzed and compared to those from a repeated strike process.The TEV waveforms during disconnector operations are recorded by a self-developed measurement system first.Then,statistical characteristics,such as the pulse number,duration of pulses,frequency components,magnitude and single pulse duration,are extracted.The transmission line theory is introduced to analyze the TEV and is validated by the experimental results.Finally,the relationship between the TEV and the repeated strike process is analyzed.This proves that the pulse voltage of the TEV is proportional to the corresponding breakdown voltage.The results contribute to the definition of the standard testing waveform of the TEV,and can aid the protection of electronic devices in substations by minimizing the threat of this phenomenon.展开更多
Gas-insulated equipment(GIE)plays a critical role in modern power systems,where reliable and accurate condition monitoring is essential for operational safety.Optical sensing technologies,benefiting from immunity to e...Gas-insulated equipment(GIE)plays a critical role in modern power systems,where reliable and accurate condition monitoring is essential for operational safety.Optical sensing technologies,benefiting from immunity to electromagnetic interference,high sensitivity,and adaptability to harsh environments,offer promising alternatives to traditional electrical sensors.This review presents a comprehensive survey of optical sensing technologies for GIE,including fiber Bragg gratings(FBG),fiber-optic interferometry,distributed acoustic and temperature sensing,gas absorption spectroscopy,and electric-field detection based on the electro-optic(EO)effect.The fundamental principles,implementation schemes,and typical applications of each method are systematically analyzed.Despite the demonstrated advantages,challenges remain in sensor packaging reliability,optical coupling efficiency,and long-term stability.Future research should focus on enhancing system robustness,spatial resolution,and integration with digital twins and intelligent diagnostic frameworks.This work seeks to bridge GIE and optical sensing technologies,facilitating the development and deployment of high-reliability optical sensing systems for the monitoring of next-generation GIE.展开更多
HFO-1234ze(E),as a new eco-friendly gas-insulated medium,demonstrates promising application prospects in medium voltage gas insulated equipment(GIE).Considering the existence of the temperature-rise effect and partial...HFO-1234ze(E),as a new eco-friendly gas-insulated medium,demonstrates promising application prospects in medium voltage gas insulated equipment(GIE).Considering the existence of the temperature-rise effect and partial overheating fault in GIE,the evaluation of the compatibility of HFO-1234ze(E)with widely used metallic copper and aluminum in GIE is necessary.Herein,we explore the interaction of HFO-1234ze(E)with copper and aluminum at 100–200°C by investigating the metal surface morphology,elemental composition as well as gas composition.It is found that the interaction of HFO-1234ze(E)with the copper interface at 17S-200°C precipitates a large number of cubic crystals,while the morphology of aluminum demonstrates no obvious change at 100–200°C.The gas composition is stable with no by-products generated after interaction.Density functional theory analysis also confirms that the C=C group in HFO-1234ze(E)demonstrates stronger interaction with Cu(111)with the new Cu-F chemical bonds formed and dominates the corrosion of copper.The related results provide an important reference for the engineered applications of HFO-1234ze(E).展开更多
Environment-friendly gas insulating mediums adapted to a DC gas-insulated transmission line(GIL)electric field condition is the key to the next generation of Environment-friendly HVDC GILs.In this paper,we review the ...Environment-friendly gas insulating mediums adapted to a DC gas-insulated transmission line(GIL)electric field condition is the key to the next generation of Environment-friendly HVDC GILs.In this paper,we review the literature on sulfur hexafluoride(SF6)alternatives including the scientific understanding,control,and implementation of gas-solid systems in this type of power transmission.First,the structure-activity relationship between the molecular structure and physico-chemical properties of Environment-friendly insulating gases is presented.Then,the search and prediction of important physicochemical properties of gases are summarized.Subsequently,in view of the potential of environmental friendly insulating gases,the swarm parameters of gas discharge and breakdown properties in a quasi-uniform field,inhomogeneous field,and at the gas-solid interface,that need to be taken into account with industrialized DC GILs are discussed.The latest research progress on insulation characteristics,especially the polarity effect in DC gas-solid insulation systems,the sensitivity to the electrode surface state,and the non-uniformity of the electric field,and the influence of metal particles and their variation with air pressure,is highlighted.In addition,the heat transfer characteristics of insulating gases,related to DC GIL transmission with a large current-carrying capacity and the influence of alternative gases on the heat transfer characteristics are described.Finally,aiming at solving the contradiction of low environmental impact,high dielectric strength and low liquefaction temperatures in the selection of alternative gases,an coordinated regulation model for Environment-friendly gases in DC GILs is established.Considerations for future work on this topic are also presented.展开更多
Gas-insulated equipment(GIE)that utilizes the most potent greenhouse gas sulfur hexafluoride(SF_(6))as insulation and arc-quenching medium has been widely used in the power industry.Seeking eco-friendly insulating gas...Gas-insulated equipment(GIE)that utilizes the most potent greenhouse gas sulfur hexafluoride(SF_(6))as insulation and arc-quenching medium has been widely used in the power industry.Seeking eco-friendly insulating gas with advanced performance for next-generation SF_(6)-free GIE is significant for the“net-zero”goal and sustainable development.In this paper,the utilization,emission,and reduction policies of SF_(6)around the world were summarized first.Then,we systematically reviewed the latest progress in comprehensive performance evaluation of eco-friendly insulating gas in terms of molecular design,dielectric insulation,arc-quenching,stability and decomposition,materials compatibility,biosafety,etc.Further,the representative applications of eco-friendly insulating gas in medium-voltage,high-voltage GIE as well as relevant maintenance-related technologies were highlighted.Accordingly,the existing challenges and future perspectives were proposed,presenting a roadmap to hopefully steer the development of eco-friendly insulating gas and GIE.展开更多
The requirements for the construction of a new power system inevitably pose significant challenges and changes to the operation and maintenance of the power grid.To ensure the safe and stable operation of ultra-high v...The requirements for the construction of a new power system inevitably pose significant challenges and changes to the operation and maintenance of the power grid.To ensure the safe and stable operation of ultra-high voltage(UHV)transmission equipment,this work reports on the principles and preliminary results of using electroluminescence(EL)-based photon counting(PC)methods for early detection of micro-defects in GIS/GIL insulation spacer.In this study,the impact of voltage,gas pressure,and gas composition on the photon response of insulation is examined.Furthermore,the corresponding relationship between defect status and photon response characteristics is explored,along with the discussion of the EL mechanism and its evolution induced by defects.The research results demonstrate that PC measurement exhibits high sensitivity to variations in millimeter-scale defect size,position,and morphology at lower electric fields before partial discharge(PD)initiation.With this regard,this paper reveals promising prospects for the early detection of micro-defects in UHV transmission equipment using PC measurement-based methods.展开更多
Since 2009,ultra-high voltage(UHV)transmission technology has been promoted and applied in China.Over the years,with the accumulation of experience in the construction and operation of UHV projects and the continuous ...Since 2009,ultra-high voltage(UHV)transmission technology has been promoted and applied in China.Over the years,with the accumulation of experience in the construction and operation of UHV projects and the continuous deepening of scientific and technological innovation,UHV technology and key equipment have made great progress.This paper introduces the main achievements of UHV technology innovation from various perspectives including electromagnetic environment,overvoltage and insulation coordination,external insulation and major equipment such as converter transformers,converter valves and gas-insulated transmission lines(GIL).展开更多
Heptafluoroisobutyrontrile(C_(3)F_(7)CN)performs well in dielectric properties and environmental protection,which has the potential to replace SF6 gas.The decomposition characteristics of C_(3)F_(7)CN mixture under fa...Heptafluoroisobutyrontrile(C_(3)F_(7)CN)performs well in dielectric properties and environmental protection,which has the potential to replace SF6 gas.The decomposition characteristics of C_(3)F_(7)CN mixture under fault conditions directly affect the possibility of its replacement for SF6 gas.However,the number of studies on the decomposition characteristics of C_(3)F_(7)CN mixture under overheating fault is less.In this paper,the decomposition characteristics of C_(3)F_(7)CN/CO_(2) mixture under an overheating fault are studied by gas chromatography-mass spectrometry(GC/MS)and quantum chemical calculations.Byproducts CO,C_(3)F_(6) and HF are detected at 200℃.At 550℃,the C_(3)F_(7)CN molecule begins to decompose and produces CHF_(3),C_(2)F_(4),CF_(3)CN and CNCN.Moreover,the results of GC/MS show that the insulation medium C_(3)F_(7)CN contains an impurity,which is C3HF7(HFC-227ea).Combined with the results of GC/MS and quantum chemistry calculations,it can be concluded that the decomposition by-product C_(3)F_(6) at 200℃ mainly comes from the decomposition of C_(3)HF_(7).C_(3)HF_(7) reduces the decomposition temperature of the C_(3)F_(7)CN/CO_(2) mixture.Therefore,it is very important to improve the purity of the insulation medium C_(3)F_(7)CN.展开更多
基金supported by the Human Resources Development of the Korea Institute of Energy Technology Evaluation and Planning(KETEP)grant funded by the Korea government Ministry of Knowledge Economy(No.RS-2023-00244330)the National Research Foundation of Korea(NRF)grant funded by the Korea government(MSIT)(No.NRF RS-2023-00219052RS-2024-00352587)。
文摘Accurately determining when and what to remanufacture is essential for maximizing the lifecycle value of industrial equipment.However,existing approaches face three significant limitations:(1)reliance on predefined mathematical models that often fail to capture equipment-specific degradation,(2)offline optimization methods that assume access to future data,and(3)the absence of component-level guidance.To address these challenges,we propose a data-driven framework for component-level decision-making.The framework leverages streaming sensor data to predict the remaining useful life(RUL)without relying on mathematical models,employs an online optimization algorithm suitable for practical settings,and,through remanufacturing simulations,provides guidance on which components should be replaced.In a case study on gas-insulated switchgear,the proposed framework achieved RUL prediction performance comparable to an oracle model in an online setting without relying on predefined mathematical models.Furthermore,by employing online optimization,it determined a remanufacturing timing close to the global optimum using only past and current data.In addition,unlike previous studies,the framework enables component-level decision-making,allowing for more detailed and actionable remanufacturing guidance in practical applications.
基金supported by the Federal Ministry for Economic Affairs and Energy, Germany (FKZ:03ET7511C)the Bavarian Ministry of Economic Affairs, Regional Development and Energy (FKZ:IET-1208-0018)
文摘The development of high-voltage direct current gas-insulated switchgear assemblies(DC GIS)of rated voltages up to±550 kV has been completed.DC GIS provide a compact technical solution with a high functional density,optimized for projects with limited space as in offshore HVDC converter platforms,onshore HVDC converter stations and transition stations between different transmission media.Up to now,no standards for testing of gas-insulated DC systems are available,although pre-standardization work is in progress within CIGRE.Some tests can be performed as required in AC GIS standards.Special aspects of DC voltage stress,like the electric field distribution of insulators influenced by the accumulation of electrical charge carriers and the operation-related inhomogeneous temperature distribution,must be considered by additional electric and thermoelectric tests.For DC GIS,the experience of long-term performance is limited today.Although ageing is expected to be of lower importance,tests are recommended.This contribution summarizes the physical and technical background to design and develop compact DC switchgear assemblies using gas-insulated technology.It explains the developed modules of the substation and gives an overview of the performed tests.Furthermore,it provides an insight in the on-going standardization activities and describes applications in converter and transition stations,showing its space-saving characteristics.
基金supported by the State Key Laboratory of Power System and Generation Equipment,Dept.of Electrical Engineering,Tsinghua University(Grant No.SKLD22M03)Taikai Innovation Funding(Grant No.JTCB202209210002).
文摘The construction of the future energy structure of China under the 2050 carbon-neutral vision requires compact direct current(DC)gas-insulation equipment as important nodes and solutions to support electric power transmission and distribution of long-distance and large-capacity.This paper reviews China's 10-year progress in DC gas-insulated equipment.Important progresses in basic research and industry perspective are presented,with related scientific issues and technical bottlenecks being discussed.The progress in DC gas-insulated equipment worldwide(Europe,Japan,America)is also reported briefly.
基金supported by the National Basic Research Program of China(973 Program) under grant 2011CB209405
文摘Transient enclosure voltage(TEV),which is a phenomenon induced by the inner dielectric breakdown of SF_6 during disconnector operations in a gas-insulated switchgear(GIS),may cause issues relating to shock hazard and electromagnetic interference to secondary equipment.This is a critical factor regarding the electromagnetic compatibility of ultra-high-voltage(UHV)substations.In this paper,the statistical characteristics of TEV at UHV level are collected from field experiments,and are analyzed and compared to those from a repeated strike process.The TEV waveforms during disconnector operations are recorded by a self-developed measurement system first.Then,statistical characteristics,such as the pulse number,duration of pulses,frequency components,magnitude and single pulse duration,are extracted.The transmission line theory is introduced to analyze the TEV and is validated by the experimental results.Finally,the relationship between the TEV and the repeated strike process is analyzed.This proves that the pulse voltage of the TEV is proportional to the corresponding breakdown voltage.The results contribute to the definition of the standard testing waveform of the TEV,and can aid the protection of electronic devices in substations by minimizing the threat of this phenomenon.
基金supported in part by Smart Grid-National Science and Technology Major Project(No.2024ZD0802405)State Key Laboratory of Power System Operation and Control(No.SKLD24KM12)National Natural Science Foundation of China(No.52407175).
文摘Gas-insulated equipment(GIE)plays a critical role in modern power systems,where reliable and accurate condition monitoring is essential for operational safety.Optical sensing technologies,benefiting from immunity to electromagnetic interference,high sensitivity,and adaptability to harsh environments,offer promising alternatives to traditional electrical sensors.This review presents a comprehensive survey of optical sensing technologies for GIE,including fiber Bragg gratings(FBG),fiber-optic interferometry,distributed acoustic and temperature sensing,gas absorption spectroscopy,and electric-field detection based on the electro-optic(EO)effect.The fundamental principles,implementation schemes,and typical applications of each method are systematically analyzed.Despite the demonstrated advantages,challenges remain in sensor packaging reliability,optical coupling efficiency,and long-term stability.Future research should focus on enhancing system robustness,spatial resolution,and integration with digital twins and intelligent diagnostic frameworks.This work seeks to bridge GIE and optical sensing technologies,facilitating the development and deployment of high-reliability optical sensing systems for the monitoring of next-generation GIE.
基金supported by the Science and Technology Project of State Grid Co.Ltd.,(No.5200-201919063A-0-0-00)。
文摘HFO-1234ze(E),as a new eco-friendly gas-insulated medium,demonstrates promising application prospects in medium voltage gas insulated equipment(GIE).Considering the existence of the temperature-rise effect and partial overheating fault in GIE,the evaluation of the compatibility of HFO-1234ze(E)with widely used metallic copper and aluminum in GIE is necessary.Herein,we explore the interaction of HFO-1234ze(E)with copper and aluminum at 100–200°C by investigating the metal surface morphology,elemental composition as well as gas composition.It is found that the interaction of HFO-1234ze(E)with the copper interface at 17S-200°C precipitates a large number of cubic crystals,while the morphology of aluminum demonstrates no obvious change at 100–200°C.The gas composition is stable with no by-products generated after interaction.Density functional theory analysis also confirms that the C=C group in HFO-1234ze(E)demonstrates stronger interaction with Cu(111)with the new Cu-F chemical bonds formed and dominates the corrosion of copper.The related results provide an important reference for the engineered applications of HFO-1234ze(E).
基金This work was supported in part by the National Basic Research Program of China(973 Program)(2014CB239500).
文摘Environment-friendly gas insulating mediums adapted to a DC gas-insulated transmission line(GIL)electric field condition is the key to the next generation of Environment-friendly HVDC GILs.In this paper,we review the literature on sulfur hexafluoride(SF6)alternatives including the scientific understanding,control,and implementation of gas-solid systems in this type of power transmission.First,the structure-activity relationship between the molecular structure and physico-chemical properties of Environment-friendly insulating gases is presented.Then,the search and prediction of important physicochemical properties of gases are summarized.Subsequently,in view of the potential of environmental friendly insulating gases,the swarm parameters of gas discharge and breakdown properties in a quasi-uniform field,inhomogeneous field,and at the gas-solid interface,that need to be taken into account with industrialized DC GILs are discussed.The latest research progress on insulation characteristics,especially the polarity effect in DC gas-solid insulation systems,the sensitivity to the electrode surface state,and the non-uniformity of the electric field,and the influence of metal particles and their variation with air pressure,is highlighted.In addition,the heat transfer characteristics of insulating gases,related to DC GIL transmission with a large current-carrying capacity and the influence of alternative gases on the heat transfer characteristics are described.Finally,aiming at solving the contradiction of low environmental impact,high dielectric strength and low liquefaction temperatures in the selection of alternative gases,an coordinated regulation model for Environment-friendly gases in DC GILs is established.Considerations for future work on this topic are also presented.
基金supported in part by the National Natural Science Foundation of China(Nos.52277144,52107145,and 51907023)the fellowship of China Postdoctoral Science Foundation(No.2022M712446).
文摘Gas-insulated equipment(GIE)that utilizes the most potent greenhouse gas sulfur hexafluoride(SF_(6))as insulation and arc-quenching medium has been widely used in the power industry.Seeking eco-friendly insulating gas with advanced performance for next-generation SF_(6)-free GIE is significant for the“net-zero”goal and sustainable development.In this paper,the utilization,emission,and reduction policies of SF_(6)around the world were summarized first.Then,we systematically reviewed the latest progress in comprehensive performance evaluation of eco-friendly insulating gas in terms of molecular design,dielectric insulation,arc-quenching,stability and decomposition,materials compatibility,biosafety,etc.Further,the representative applications of eco-friendly insulating gas in medium-voltage,high-voltage GIE as well as relevant maintenance-related technologies were highlighted.Accordingly,the existing challenges and future perspectives were proposed,presenting a roadmap to hopefully steer the development of eco-friendly insulating gas and GIE.
基金supported by the National Natural Science Foundation of China under Grant No.52125703.
文摘The requirements for the construction of a new power system inevitably pose significant challenges and changes to the operation and maintenance of the power grid.To ensure the safe and stable operation of ultra-high voltage(UHV)transmission equipment,this work reports on the principles and preliminary results of using electroluminescence(EL)-based photon counting(PC)methods for early detection of micro-defects in GIS/GIL insulation spacer.In this study,the impact of voltage,gas pressure,and gas composition on the photon response of insulation is examined.Furthermore,the corresponding relationship between defect status and photon response characteristics is explored,along with the discussion of the EL mechanism and its evolution induced by defects.The research results demonstrate that PC measurement exhibits high sensitivity to variations in millimeter-scale defect size,position,and morphology at lower electric fields before partial discharge(PD)initiation.With this regard,this paper reveals promising prospects for the early detection of micro-defects in UHV transmission equipment using PC measurement-based methods.
文摘Since 2009,ultra-high voltage(UHV)transmission technology has been promoted and applied in China.Over the years,with the accumulation of experience in the construction and operation of UHV projects and the continuous deepening of scientific and technological innovation,UHV technology and key equipment have made great progress.This paper introduces the main achievements of UHV technology innovation from various perspectives including electromagnetic environment,overvoltage and insulation coordination,external insulation and major equipment such as converter transformers,converter valves and gas-insulated transmission lines(GIL).
基金supported by the National Key R&D Program of China(2017YFB0902500)Science&Technology Project of State Corporation of China:The Environment-Friendly Gas-Insulated Transmission Line(GIL)and National Natural Science Foundation of China(51877203)。
文摘Heptafluoroisobutyrontrile(C_(3)F_(7)CN)performs well in dielectric properties and environmental protection,which has the potential to replace SF6 gas.The decomposition characteristics of C_(3)F_(7)CN mixture under fault conditions directly affect the possibility of its replacement for SF6 gas.However,the number of studies on the decomposition characteristics of C_(3)F_(7)CN mixture under overheating fault is less.In this paper,the decomposition characteristics of C_(3)F_(7)CN/CO_(2) mixture under an overheating fault are studied by gas chromatography-mass spectrometry(GC/MS)and quantum chemical calculations.Byproducts CO,C_(3)F_(6) and HF are detected at 200℃.At 550℃,the C_(3)F_(7)CN molecule begins to decompose and produces CHF_(3),C_(2)F_(4),CF_(3)CN and CNCN.Moreover,the results of GC/MS show that the insulation medium C_(3)F_(7)CN contains an impurity,which is C3HF7(HFC-227ea).Combined with the results of GC/MS and quantum chemistry calculations,it can be concluded that the decomposition by-product C_(3)F_(6) at 200℃ mainly comes from the decomposition of C_(3)HF_(7).C_(3)HF_(7) reduces the decomposition temperature of the C_(3)F_(7)CN/CO_(2) mixture.Therefore,it is very important to improve the purity of the insulation medium C_(3)F_(7)CN.